The HDM97 Pocket Reference Meter series allows for highly accurate and reliable measurement of conductivity, temperature, pressure, pH and flow for hemodialysis machines and RO-Water Systems. The meter integrates 30 years of experience in dialysis reference meters into an advanced device with selectable conductivity temperature coefficients for high accuracy measurements. Key features include a multifunctional conductivity probe, long-term data acquisition, pressure drop measurement mode, and FDA 510(k) approval. The meters are produced under certified quality standards and offer an annual calibration service traceable to international standards.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
226 views2 pages

19 IBP Medical Sheets BiotechLab HDM97Pocket Brochure English R04

The HDM97 Pocket Reference Meter series allows for highly accurate and reliable measurement of conductivity, temperature, pressure, pH and flow for hemodialysis machines and RO-Water Systems. The meter integrates 30 years of experience in dialysis reference meters into an advanced device with selectable conductivity temperature coefficients for high accuracy measurements. Key features include a multifunctional conductivity probe, long-term data acquisition, pressure drop measurement mode, and FDA 510(k) approval. The meters are produced under certified quality standards and offer an annual calibration service traceable to international standards.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

HDM97Pocket

Reference Meter Product Family

HDM97BQ APPLICATIONS
» Conductivity » Hemodialysis machines
» Temperature » RO-Water Systems
» Pressure
» Flow
KEY FEATURES
HDM97BP » Can be used with any brand of
» Conductivity dialysis machine
» Temperature » Selectable conductivity temperature
» Pressure coefficient for high accuracy
» pH conductivity measurement

HDM97BP
» Conductivity
» Temperature
» Pressure
» pH » Allows conductivity measurement of
RO water
HDM97BN » With special option blood pressure
» Conductivity meters can be calibrated
» Temperature » Timer function
» Pressure drop measurement
HDM97BM » Allows field calibration FDA
» Pressure 510(k) approval
» USB Computer Interface
HDM97BL for data acquisition
» Flow » FDA 510(k) approval

Dialysis Requires Reliability and Accuracy intelligent power management allows the meter to run
Advanced technology Hemodialysis calls for high reliability continuously for more than 200 hours
and extreme accuracy. The HDM97 Pocket Reference Meter
series allows highly accurate and reliable measurement of Details Technicians Are Looking For
conductivity, temperature, pressure, pH and flow. The device The guiding principle in the development of the HDM97 was:
has been developed by specialists and integrates the knowhow “What are the daily needs of the busy dialysis technician?”
and experience of 30 years in the design of reference meters The outcome is a collection of innovative details available
for dialysis. Intelligent product details along with innovative only from IBP dialysis reference meters: Multifunctional
technology deliver great value Conductivity probe, long term data acquistion and pressure drop
measurement mode are the features technicians are
Advanced Technology searching for.
Advanced electronic technology combined with highly developed
software results in a completely new type of measuring Quality
instrument with special features on a level of accuracy not The HDM97Pocket meters are produced under certified ISO
achievable with other units. To achieve the highest conductivity 13485 quality management system. The HDM97Pocket reference
measurement accuracy possible the conductivity temperature meters are registered as medical devices in USA. We offer an
coefficient is selectable by dialysis machine manufacturer. annual calibration service traceable to PTB and NIST with
A rechargeable Li-Ion-Polymer battery in combination with certification in accordance with the ISO 17025 standard.

www.ibpmt.com
HDM97 Pocket
Specifications
Details Technicians Are Looking For
CONDUCTIVITY Modern 4-pole electrode in carbon plastic technology
for conductivity measurement. Years of experience
Only Version BN, BO, BP and BQ have proven this design and construction absolutely
Range 0 … 30 mS/cm
linear and stable. The Electrode may be used either as
Accuracy 0 … 200 uS/cm +/- 0.6 uS/cm a flow through or dip electrode. May also be used for
201… 2000 uS/cm +/- 6 uS/cm testing RO water. The pressure connector has an
2 … 30.00 mS/cm automatic closure. This enables the measurement of
12 … 16 mS/cm +/- 0.03 mS/cm
dialysate pressure without any additional adapters.
otherwise +/- 0.06 mS/cm
> 30 mS/cm +/- 1% from URV
Temperature coefficient selectable.
Helpful Options
TEMPERATURE » For pressure measurement optionally a higher
Only Version BN, BO, BP and BQ accuracy is available which allows calibration of
Range 0 to 100 °C blood pressure measurement devices in accordance
Resolution 0.01 °C
Accuracy 25 … 40 °C +/- 0.05 °C
with DIN EN 1060.
otherwise +/- 0.1°C
» A timer mode, with start stop function, allows to
PRESSURE measure time period with a resolution of 100 msec
Only Version BO, BP and BQ
Units mmHg, kPa, mbar, PSI - selectable » The and version allows flow measurement
Range -700 …1900 mmHg (2.5 Bar)
to calibrate dialysate flow as well blood and
Resolution 0.1 mmHg
Accuracy 0 … 300 mmHg +/- 1 mmHg infusion pumps.
Otherwise +/- 2 mmHg
Ceramic Sensor fluid resistant » The HDM97 meter has an USB interface for
Only Version BM and option H for BO, BP and BQ easy connection to a personal computer.
Range -700 …1900 mmHg (2.5 Bar)
The IBPView software allows the user to
Resolution 0.01 mmHg
Accuracy 0 … 300 mmHg +/- 0.5 mmHg collect, store and visualize data taken from
301 … 1000 mmHg +/- 1 mmHg measurements with the HDM97 .
Otherwise +/- 2 mmHg
FLOW » For pressure measurement on Fresenius machines
Only Version BL and BQ an adapter is available.
Range 100 … 2000 ml/min
Resolution 1 ml/min
Accuracy 100 … 500 ml/min +/- 1,5 % of MBE
» For convenient attachment of the meter
Otherwise +/- 2,5 % of MBE to the infusion pole a fold-away holder is
part of the meter. This movable holder also
pH
allows use of the meter in a tilt position on a
Only Version BP
Range pH 0 … 14 flat surface.
Resolution pH 0.01
Accuracy pH +/- 0.02
For complete details on IBP products visit:
www.ibpmedical.com
Interface USB 2.0 - electrically insulated
IBP Medical GmbH
Power supply Internal rechargeable - LI-Ion-Polymer battery
Ikarusalle 15
External charger Input 100 … 245 V / 50/60 Hz
30179 Hannover
Output 5 V DC, 500 mA
Germany
Or via USB-Interface from a computer
Phone: +49 511 651647
Dimensions 165 x 82 x 33 mm - 6.5” x 3.2” x 1.3”
Fax: +49 511 652284
& Weight 0.4 Kg - 0.88 lbs including probe eMail: [email protected]

www.ibpmedical.com Biotech-Lab