Product Information

Zytel ®

nylon resin

Zytel® 101 NC010


Nylon Resin
Zytel® 101 NC010 is a general purpose, molding grade PA 66 resin.
Property Test Method Units Value
DAM 50%RH
Mechanical
Tensile Strength ASTM D 638 MPa (kpsi) 83 (12.0) 77.2 (11.2)
Tensile Strength at Yield ASTM D 638 MPa (kpsi) 83 (12.0) 58 (8.5)
Elongation at Yield ASTM D 638 % 5 25
Elongation at Break ASTM D 638 % 60 >300
Poisson's Ratio 0.41
Flexural Modulus ASTM D 790 MPa (kpsi) 2830 (410) 1210 (175)
Izod Impact ASTM D 256 J/m (ft lb/in) 53 (1.0) 112 (2.1)
Thermal
Heat Deflection Temperature ASTM D 648 °C (°F)
0.45MPa (66psi) 210 (410)
1.8MPa (264psi) 65 (149)
CLTE, Parallel ASTM D 696 E-4/C (E-4/F) 0.7 (0.39)
Melting Point ASTM D 3418 °C (°F) 262 (504)
Electrical
Volume Resistivity ASTM D 257 ohm cm 1 E15 1 E13
Dielectric Strength, Short Time ASTM D 149 kV/mm (V/mil)
3.2mm (0.126in) 18.1 (360)
Dielectric Constant ASTM D 150
1E2 Hz 4.0 8.0
1E3 Hz 3.9 7.0
1E6 Hz 3.6 4.6
Dissipation Factor ASTM D 150
1E2 Hz 0.01 0.20
1E3 Hz 0.02 0.20
1E6 Hz 0.02 0.10
Flammability
Rating @ Thickness UL94 V-2
Thickness Tested UL94 mm 0.71
Contact DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, etc.
Mechanical properties measured at 23°C (73°F) unless otherwise stated.

®
Zytel is a DuPont registered trademark. 951001/991026
The information provided in this data sheet corresponds to our knowledge on the subject at the date of its publication. This information may be subject to revision as new
knowledge and experience becomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated;
these data may not be valid for such material used in combination with any other materials or additives or in any process, unless expressly indicated otherwise. The data
provided should not be used to establish specification limits or used alone as the basis of design; they are not intended to substitute for any testing you may need to
conduct to determine for yourself the suitability of a specific material for your particular purposes. Since DuPont cannot anticipate all variations in actual end-use
conditions DuPont makes no warranties and assumes no liability in connection with any use of this information. Nothing in this publication is to be considered as a
license to operate under or a recommendation to infringe any patent rights. Caution: Do not use this product in medical applications involving permanent implantation
in the human body. For other medical applications see "DuPont Medical Caution Statement", H-51459 or H-50102.

Start with DuPont Engineering Polymers - www.dupont.com/enggpolymers


Product Information

Zytel® 101 NC010


Property Test Method Units Value
DAM 50%RH
Other
Specific Gravity ASTM D 792 1.14
Hardness, Rockwell ASTM D 785
Scale M 79 59
Scale R 121 108
Taber Abrasion ASTM D 1044 mg
CS-17 Wheel, 1kg, 1000 cycles 7
Water Absorption ASTM D 570 %
Immersion 24h 1.2
Saturation 8.5
Mold Shrinkage %
Flow, 3.2mm (0.126in) 1.5
Processing
Melt Temperature Range °C (°F) 280-305 (535-580)
Mold Temperature Range °C (°F) 40-95 (100-200)
Processing Moisture Content % <0.2
Contact DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, etc.
Mechanical properties measured at 23°C (73°F) unless otherwise stated.

Zytel® is a DuPont registered trademark. 951001/991026


The information provided in this data sheet corresponds to our knowledge on the subject at the date of its publication. This information may be subject to revision as new
knowledge and experience becomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated;
these data may not be valid for such material used in combination with any other materials or additives or in any process, unless expressly indicated otherwise. The data
provided should not be used to establish specification limits or used alone as the basis of design; they are not intended to substitute for any testing you may need to
conduct to determine for yourself the suitability of a specific material for your particular purposes. Since DuPont cannot anticipate all variations in actual end-use
conditions DuPont makes no warranties and assumes no liability in connection with any use of this information. Nothing in this publication is to be considered as a
license to operate under or a recommendation to infringe any patent rights. Caution: Do not use this product in medical applications involving permanent implantation
in the human body. For other medical applications see "DuPont Medical Caution Statement", H-51459 or H-50102.

Start with DuPont Engineering Polymers - www.dupont.com/enggpolymers