5100
SERIES
Toughened, weather resistant,
data displays with integral
USB 2.0 interface
These robust, monochrome displays are
ideal for use in exposed or industrial
environments. Bright white transflective
display technology is securely encased
within a sealed and impact resistant bezel.
The bezel features a hard coated UV and
scratch resistant, polycarbonate window.
Available in either 20 character x 4 line, 20 character x 8
line or 128 x 64 pixel graphic versions these USB 2.0
display devices can be easily installed into any control
panel or equipment enclosure.
The display assemblies can be specified with or without
three independently illuminated menu navigation keys.
Illumination is under software control (on/off/flashing).
Offered in eight different configurations/specifications,
Storm 5100 Series Displays are rated for use in either
Industrial (IND) or Extreme (EXM) environments. They
offer a ‘ready to use’ display solution for a wide range of
indoor or outdoor applications.
Performance
Operational key life: >2 million cycles per key
Environmental
Operational temperature: 0ºC to +60ºC
(optionally -20ºC to +70ºC)
Storage temperature: -20ºC to +70ºC
102
Humidity: 5%RH to 95%RH
non-condensing
Vibration and shock: ETSI 300 019 5M3
UV
(optionally 6M3)
Water and dust resistance: IP54 (optionally IP65)
Impact resistant: 5J (optionally 10J)
102 32
Electrical
All dimensions in mm Insulation resistance: 50Mohms (min)
Breakdown voltage: 500V a.c. (60 secs)
Max Operating voltage: 5V
• Impact, shock and vibration resistant Max Operating current: 50mA
• Sealed for use in wet or dirty environments
Compliance
• Weather resistant for use in exposed locations This device is designed to meet:
(optional feature) • EU RoHS
• EU Low Voltage Directive
• Extended operational temperature range -20ºC to +70ºC • ESD: Up to +/- 15kV air discharge, +/- 7.5kV contact discharge
(optional feature) • WEEE Directive
• EMC-CE, FCC Part 15B Class B
• Programmable USB display controller and system interface • EN55022 Class B, EN60950, EN55024
• Display connects to the host system via a single USB cable
Additional Information
with a USB Mini-B connector (cable supplied separately) (downloads available at www.storm-interface.com)
• Resistant to petrochemicals, detergents and most • Engineering Manual including product dimensions
and installation / configuration instructions
commonly used non-abrasive cleaning agents • CAD files (dxf, dwg)
• Responsive, illuminated menu navigation keys under • API Object code libraries
software control (on/off /flashing) (optional feature) • Test data and reports
• Easy to use API with downloadable object code libraries Accessories
• USB Cable for use with USB Interface
• USB 2.0 HID compliant device • Under panel fitting kit
5100
SERIES
Configuration Utility Software for Storm
5100 Series Toughened USB 2.0 Data Displays 5100 (IND) 5100 (EXM)
Storm 5100 Series Toughened Data Displays can be
configured by the Configuration Utility Software via the
Application Programming Interface for Windows (API).
These software tools are available free of charge and Storm • USB • USB
can be downloaded from www.storm-interface.com. 5100 Series • 3 keys or • 3 keys or
Please note: Registration is required for download. character display only display only
display • 4 or 8 line • 4 or 8 line
x 20 characters x 20 characters
Primary Features of the Configuration Utility
• IP54 • IP65
• Selection of font for 5100 Series character displays
• 0°C to 60°C • -20°C to 70°C
Two standard fonts are available:
• 5J impact • 10J impact
6 x 8. This provides 8 lines with 20 characters per line
• shock and vibration • shock and vibration
6 x 16. This provides 4 lines with 20 characters per line IEC721-5M3 IEC721-6M3
Each font includes the following character set:
!"#$%&'()*+,.\0123456789:;<=>?@ABCDEFGHIJKLMNOPQR
STUVWXYZ[/]^_'abcdefghijklmnopqstuvwxyz{|}~ 5100 (IND) 5100 (EXM)
There is also a large font numeric character set:
0123456789,.º±
• The 5100 Series graphic display is 128 x 64 pixels.
• Features supported by the Configuration Utility Storm • USB • USB
and API include: 5100 Series • 3 keys or • 3 keys or
graphic display only display only
Integral display Circle, rectangle • 128 x 64 pixels • 128 x 64 pixels
display
backlight (on/off/flashing) and line
• IP54 • IP65
Illumination of three Bar graph • 0°C to 60°C • -20°C to 70°C
navigation keys Large font • 5J impact • 10J impact
(on/off/flashing)
Re-set to factory default • shock and vibration • shock and vibration
Display contrast level IEC721-5M3 IEC721-6M3
Firmware updates
Flip (180° rotation)
Inverse (white on black)
• The utility will load up to four bitmap graphic icons
(maximum size 128 x 64 pixels). Any one icon can be set
as the default ‘power-up’ screen. Icons can be originated
using Microsoft Paint and previewed using the
Configuration Utility before loading to the display.
• The display enumerates as an HID compliant device.
Windows and Microsoft Paint are recognised trademarks of the Microsoft Corporation.
Part Numbers
5100 (IND) – INDUSTRIAL Accessories
4 or 8 x 20 character display, 3 keys 5103-000 USB Cable 4500-01
128 x 64 pixel graphic display, 3 keys 5103-100 (USB A to
90º USB mini-B) For more information & to order:
4 or 8 x 20 character display, display only 5100-000
128 x 64 pixel graphic display, display only 5100-100 Under panel
fitting kit
5100-FK0
www.storm-interface.com
5100 (EXM) – EXTREME Whilst every effort Storm Interface products include technology
is made to ensure protected by international patents and
details are correct
4 or 8 x 20 character display, 3 keys 5103-010 at time of print,
design registration. All rights reserved.
128 x 64 pixel graphic display, 3 keys 5103-110 specifications are
subject to change
Storm is a trademark of
Keymat Technology Ltd
without notice. Storm Interface is a
4 or 8 x 20 character display, display only 5100-010 trading name of Keymat
Technology Ltd 003
128 x 64 pixel graphic display, display only 5100-110 Designed & produced
by NIK Design
[email protected] 5100 Jan 2014 FM 39602