0% found this document useful (0 votes)
55 views2 pages

ZENNER Single Jet ETKD-N, 2-Page BROCHURE

This document provides technical specifications for single jet dry dial water meters, models ETKD-N DN 15 and DN 20, including: 1) Flowrate ranges of 1.6-4 m3/h and 1-5 m3/h respectively. 2) Measuring ranges and metrological classes of B-H/A-V. 3) Operating pressures up to 16 bar, pulse values of 1/10 liter, and pressure losses of 0.63 bar at maximum flow.

Uploaded by

Vikram S Gadre
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
55 views2 pages

ZENNER Single Jet ETKD-N, 2-Page BROCHURE

This document provides technical specifications for single jet dry dial water meters, models ETKD-N DN 15 and DN 20, including: 1) Flowrate ranges of 1.6-4 m3/h and 1-5 m3/h respectively. 2) Measuring ranges and metrological classes of B-H/A-V. 3) Operating pressures up to 16 bar, pulse values of 1/10 liter, and pressure losses of 0.63 bar at maximum flow.

Uploaded by

Vikram S Gadre
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

EnergyMetering

Apartment water meters


Single Jet Dry Dial (Pre-equipped for AMR)

ETKD-N (DN 15 & DN 20)

All that counts.


Fitting meters

Technical data ETKD-N

Permanent Flowrate Q3 m³/h 1.6 4


Comparable to nominal flow (EWG) Qn m³/h 1.0 2.5
Attainable measuring range Q3/Q1 R 80H/40V 80H/40V
Standard measuring range (1) Q 3/Q1 R 80H/40V 80H/40V
1

Comparable to metrological class


class B-H/A-V B-H/A-V
(EWG)
Q
Overload Flowrate 4 m³/h 2 5
Minimum Flowrate (2) Q1 l/h 20H 50H/100V
Start-up flow rate - l/h <10 <14
Display range min l 0.02 0.02
R8 99.999,99 R8 99.999,99
max m³
R7 99.999,99 R7 99.999,99
T30 0,1 - 30 0,1 - 30
Temperature range

Operating pressure, max. MAP bar 16 16


Pulse value - l/pulse 1/10 1/10
Pressure loss at Q3 p bar 0.63 0.63
Mechanical environmental condition - - M1 M1

Climatic condition ( 3) - °C 5 - 70 5 - 70

Flow profile sensitivity - - U0/D0 U0/D0

Weight and dimensions:

Nominal diameter DN mm 15 20
inch ½ ¾
Overall length L2 mm 110 130
Overall length with connectors approx. L1 mm 190 226
Thread meter G x B D1 inch ¾ 1
Thread connector D2 inch ½ ¾
Width approx. B mm 66 66
Height approx. H1 mm 77 80
Weight ca. - kg 0.43 0.57
(1)Other measuring ranges (R) on request
(2) The data refer to the standard measuring range
(3) Condensation possible

Q3 = 1,6 - 2,5

Q
3 =4

Q1 = Minimum Flowrate
Q2 = Transitional Flowrate
Q3 = Permanent Flowrate
Q4 = Overload Flowrate

flow rate [m3/h]

Dimensions ETKD-N Typical pressure loss curve Typical accuracy curve