0% found this document useful (0 votes)
68 views35 pages

Stormwater Management Solutions

This document provides information about stormwater management and Graf's production facilities. It summarizes Graf's 50 years of experience producing high-quality plastic products for rainwater harvesting. It describes Graf's state-of-the-art production facility in Teningen, Germany, which implements quality control processes like checking each tank for accuracy and documenting all production parameters. The document also emphasizes Graf's commitment to sustainable production methods.

Uploaded by

Dominik_Ljubicic
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
68 views35 pages

Stormwater Management Solutions

This document provides information about stormwater management and Graf's production facilities. It summarizes Graf's 50 years of experience producing high-quality plastic products for rainwater harvesting. It describes Graf's state-of-the-art production facility in Teningen, Germany, which implements quality control processes like checking each tank for accuracy and documenting all production parameters. The document also emphasizes Graf's commitment to sustainable production methods.

Uploaded by

Dominik_Ljubicic
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 35

Stormwater Management

Stormwater
Management

The infiltration range


Infiltration modules
Infiltration filters
Retention cisterns
Shafts and accessories

EN V36
960288
Production site in Dachstein (France)

Production site in Teningen (Germany) near Freiburg

GRAF – Setting standards in quality High Quality Manufacturing


For 50 years, Otto Graf GmbH has been offering high-class plastic products to its customers. In 1974, Our products have to satisfy a huge number of different requirements, which is why GRAF is an expert in
GRAF developed its first pioneering range of rainwater harvesting products. Today we are market all the common procedures for manufacturing plastic products and has access to the optimum manufac-
leader in numerous countries for Rainwater Harvesting Systems. turing process for every product.

High Quality Manufacturing Quality is at the forefront Our goal: your satisfaction Ecological products from the Long product lives ensure that fewer re- tured in an environmentally-sound way.
Graf is investing continuously in the ex- More than 100,000 satisfied customers technology leader sources are used and the environmental For example, the injection moulding pro-
To ensure consistent high product
impact is minimised. All products manu- cess consumes up to 85 % less energy
pansion of the headquaters in Teningen quality, you need optimised produc- already benefit from the advantages of GRAF uses state-of-the-art production
factured by GRAF are 100 % recyclable. than normal.
near Freiburg (Breisgau). The facility has tion processes and outstanding quality GRAF rainwater harvesting systems. facilities. This is the only way to guar-
now an approximate area of 155.000 m2 management. Every individual tank at antee superlative quality at attractive
Some products are also made from recy- The heat generated during manufac-
and is one of the most modern produc- the new production site in Teningen is prices. GRAF broke new ground by using
cled materials – yet another boost to the turing is processed by a modern heat
tion facilities for plastic products in the checked for dimensional accuracy, wall injection embossing to make the Carat
environmental credentials of the GRAF recovery system and is used to heat the
world. thickness and weight. underground tank. To manufacture
product range. This means that not only production and logistics building.
Our choice of Germany for the new pro- All production parameters, e.g. material this tank, the company developed and
do GRAF products protect the environ-
duction site was easy. On the one hand, composition, machine settings and the constructed the world's largest injection
ment during use but their manufacturing
we feel an obligation to the site because staff involved in the production process, moulding machine.
Manufacturing certified process is also ecologically sound.
of our history. On the other, we would are documented for each individual
according to ISO 9001
like to offer our customers products of product. Durable and 100 % recyclable
the highest quality.
Sustainable production processes Manufacturing certified
Right from the stage of developing its according to ISO 50001
While GRAF products help protect the
products, GRAF attaches great impor-
environment, they are also manufac-
tance to sustainable product design.

World's biggest injection moulding machine Blow moulding process Rotational moulding

2 Otto Graf GmbH Otto Graf GmbH 3


Content Advice, planning
and products from one source
Preserving the natural cycle 9
 Basic information Dimensioning and planning of infiltration systems
Loads and angles of friction
10
12
What we offer:
l Dimensioning according to DWA-A 138 and DWA-M 153 for infiltration systems
System overview 18 l Sizing for infiltration / retention systems
l Overflow verification according to DIN1986-100
The system at a glance 20
l Assistance with drainage planning proposal
EcoBloc system Vario 800 flex shaft 24
l Assistance with and evaluation of soil survey
Accessories 27
Technical data 28
IT
Application examples 30
G F O R MS VIS
I N
FOR SIZ raf-water.com
www . g
System overview 38
Infiltration Tunnel /
The system at a glance 40
Infiltration Tunnel twin
Technical data 43
Application examples 44

Infiltration and Multi shaft system 49


Infiltration and Multi
Shaft system DN 400 (16") 50
shaft system
Shaft system DN 600 (24") 51

Universal filter 3 external, Universal industrial filter 3 external 52


Filter technology
Infiltration filter shaft, settling filter shaft 53

KLsepa.compact Light fluid separator 54

Detention/Retention overview 57
Detention Carat S On-site support:
58
Retention Carat S 59 If you are planning an infiltration system and need on-site we can help. We work with you to develop customised systems
Detention Platin assistance or one-to-one advice from our technical team, then to clean, store, infiltrate, attenuate or harvest rainwater.
Water detention and 60
retention systems Retention Platin 61
Detention/Retention Carat XL 62
Detention/Retention Carat XXL 64
Detention/Infiltration Herkules 66

Webcode G4107
Symbols in the catalogue
The webcode will lead
Load capacity
you directly to the
required information. Suitable for pedestrian loading

l Installation instructions Suitable for vehicle loading


l Technical drawings
l Detailed product information
Lorry-bearing
www.graf-water.com l Downloads

4 Otto Graf GmbH Otto Graf GmbH 5


Internationally proven:
GRAF infiltration technology
Stormwater management ▸ References

Stormwater management ▸ References


Business Park, Hradec Králové (CZ) Industrial building, Tumeltsham (AT)

Car dealership, Sofia (BG) Energy supplier, Warwick (UK) DIY chain store, Bratislava (SK) Recycling centre, Vresová (CZ)

Military building, Mazuren (PL) Production site, Ludwigsfelde (DE)

Shopping center, Kent (UK) Industrial building, Merseburg (DE) Football stadium, Le Havre (FR) City park, Barcelona (ES)

6 Otto Graf GmbH Otto Graf GmbH 7


Internationally proven: Preserving the natural cycle
GRAF infiltration technology

Surface sealing disrupts Decentralised infiltration promotes


groundwater recharge groundwater recharge

Stormwater management ▸ Basic information


Stormwater management ▸ References

DIY chain store, Århus (DK)

Drain/
Sewer

Infiltration

Groundwater level sinks Groundwater level rises

Housing development, Singapur (SG) Housing development, Buenos Aires (AR)

Legal change
With the adoption of the European Water Framework Directive The infiltration of rainwater locally offers considerable advan-
(2000/60/EC), the European Parliament and of the council tages over the previously customary draining into combined
has set the goal of using water more sustainably and in a more wastewater/separate sewage systems:
environmentally friendly way. The European states will be
responsible for implementing this directive.
l Promotes groundwater recharge
The Water Resources Acts of most European countries will
l R
 educes costs through lower structural costs – sewers in the
therefore be amended. The implementations can be found in
separate network and wastewater lifting units can be dimen-
many current versions – among others:
sioned on a smaller scale
"rainwater should be drained away and irrigated locally …, as
l R
 educes the effects of surface sealing
long as this is not opposed by water legislation, other provi-
Warehouse, Prag (CZ) sions of public law or water management issues." l M
 inimises the hydraulic loads in the sewer system
during storms
l Contributes to flooding prevention

Industrial warehouse, Raben (PL) Restaurant, Stockholm (SE)

8 Otto Graf GmbH Otto Graf GmbH 9


Dimensioning and planning of
infiltration systems

Examination of the ground


The following parameters are required to evaluate an infiltration system:
Stormwater management ▸ Basic information

Stormwater management ▸ Basic information


The ground conditions and the layer tion or evaluations for the construction ity). However, the ground may display
structure play an essential role in the of an infiltration system can be found a maximum permeability of ≤ 1 x 10–3
3Determination of the catchment areas planning of an infiltration system. The in most soil reports. The result of the m/s, since a minimum retention period
Connected roofs, road spaces or other sealed surfaces are evaluated with regard to the actual outflow. permeability of the ground and the window sampling or trenching is a layer should be achieved in the soil layers
ground/stratum water define the size model which depicts the ground types before entry of groundwater.
3Examination of the ground and location of the ditch. A soil report and their distribution and thickness
Determination of the permeability of the ground (kf value in m/s). This value plays a decisive role and a should at the least include window sam- down to the digging depth. Infiltration If the ground properties do not permit
miscalculation can have far-reaching consequences. pling or trenching near the installation systems must not be installed in layers, infiltration, the required kf values can
location for the evaluation of the infiltra- with permeability of < 1 x 10–6 m/s (clay be achieved using soil replacement in
3Return period tion performance. In addition, informa- or cohesive soil with high clay capac- special cases.
An infiltration or retention system is designed as a function of heavy rainfall events that are likely to occur
over a given period of time. This period of time may vary from 5 to 100 years due to local government laws
and regulations. Most of the calculations are done with 5 year rain data.

Recommended permeability values:


Soil type Suitable soil for infiltration
Coarse gravel
Determination of the
Fine gravel
catchment areas Gravel/sand mix
The collected rainwater can be fed into Medium sand
ditches and drained away from roof Fine sand
surfaces, parking areas, paving and Sand with a loam capacity
other sealed surfaces. Evaporation and Silt (loam)
the partially direct infiltration through
Loam with a clay capacity
the collection surfaces result in a reduc-
Clay
tion of the amount of rain that ends up
Permeability values weak medium strong
in the infiltration system. This leads to
differing outflow coefficients for the con-
nected surface types (see table below).
The projected surfaces are relevant for
the evaluation of the amount of rain
and may deviate substantially from the
roof surface, particularly in the case of Return period
sloping roofs. projected roof surface The size of an infiltration or deten-
The effectively impermeable surface for tion system depends on heavy rainfall 400 8000
projected courtyard surface
events which occur over a given period rain volume [ l/100 m² ]
ditch evaluation can be evaluated using
of time. This period of time may vary rain flow [ l/(s*ha) ]
the outflow coefficient and the catch- 350 7000
ment area. from 5 to 100 years due to local govern-
ment laws and regulations. Most of the
calculations are done with 5 year rain 300 6000
data, see picture/table below.
250 5000
Values given as an example:
D rain flow rain volume 200 4000
Type of surface [min] [l/s*ha] [l/100 m²]
5 380.7 1142.1
150 3000
10 245.6 1473.6
20 158.9 1906.8
30 123.4 2221.2 100 2000

Roof surfaces (95 %) Concrete blocks (90 %) Natural/composite stone (25 %) Turf (10 %) 60 80.3 2890.8
120 47.8 3441.6 50 1000
240 28.4 4089.6
540 15.5 5022
0 0
720 12.5 5400
log D [min]
1440 7.3 6307.2
2880 4.1 7084.8 In combination with soil type, the critical value (max. value for infiltration system
Asphalt and concrete (90 %) Paving with sealed joints (75 %) Paving with open joints (75 %) Gravel path (30 %)
4320 2.9 7516.8 dimensions) could lie between 5 minutes (good soil) and 4320 minutes (clay or loam).

10 Otto Graf GmbH Otto Graf GmbH 11


Loads and angles of friction

The installation depths and maximum fill cover heights are is decisive. To achieve even loading of the infiltration system Traffic loads
very much dependent on the loading of the finished surface elements, a suitable minimum soil cover is required. The
Stormwater management ▸ Basic information

Stormwater management ▸ Basic information


and the type of system material used. When a vehicle makes infiltration system elements are also subject to horizontal loa-
contact with the surface, its weight is first converted into a ding, resulting from the vertical loading being diverted by the Point load
The infiltration system elements can be installed in areas Load [kN/m²]
point load. The asphalt structure and the soil layers beneath internal rigidity of the filler material in the soil. The horizontal
it distribute this load according to their mechanical proper- loading limits the maximum depth at which the infiltration of pedestrian loading (without vehicle traffic) and areas
ties. For the soil layers, the angle of friction φ' (see page 13) system elements can be installed. with calmed vehicle traffic up to a maximum total weight of
60 tons. This includes car parks and access roads with low
speeds. In areas of pedestrian loading, traffic load is normally
assumed to be 0 kN/m². In areas with traffic loading, a distinc-
tion must be made between point loads and distributed loads.
Point loads decrease exponentially as depth increases, partly
related to the angle of friction. The fill material reduces the
point load and causes the traffic load to be evenly distributed.

Installation depth [m]

Equivalent load
Load [kN/m²]
National standards also require the equivalent load for road
surfaces to be taken into account. In theory, the equivalent
load is an evenly distributed load (e.g. national standards in
Point load Germany use Lorry 60 t ≙ 33.3 kN/m² equivalent load, British
standards use 10 kN/m² w/o safety factors for high loading
Equivalent load distributed loads) based on the total weight of the vehicle in
Vertical load resulting from relation to the projected contact area. For a theoretical load
Vertical soil pressure
soil pressure + traffic load calculation the equivalent load is not dependent on the instal-
lation depth and therefore remains constant.
Horizontal load resulting from
soil pressure + traffic load

Installation depth [m]

Result: traffic load Point load Equivalent load Traffic load


To assess traffic load, the maximum point load or equivalent Load [kN/m²] Load [kN/m²] Load [kN/m²]
load must always be used for design purposes.

Installation depth [m] Installation depth [m] Installation depth [m]

12 Otto Graf GmbH Otto Graf GmbH 13


Loads and angles of friction
continued

Vertical soil pressure Horizontal load


Stormwater management ▸ Basic information

Stormwater management ▸ Basic information


Load [kN/m²]
The covering soil layers / soil fill cover produce vertical soil The angle of friction has an important influence on the hori- The horizontal load is also dependent on the height of the fill
pressure. This is linear and depends on the installation depth zontal loading. Part of this vertical load is converted into a cover, i.e. the installation depth, and limits the installation
/ height of the fill cover and the density of the chosen material. horizontal load by the internal rigidity of the filler material. window for the infiltration ditch elements.
The vertical soil pressure is normally estimated to be around
20 kN/m² per metre of fill cover.
Suitable for
Class Car Lorry 12 Lorry 30 Lorry 40 Lorry 60
pedestrian loading
Installation depth (max.) [m]
3.00 3.00 3.00 2.75 2.50 2.25
φ' = 20°
Installation depth (max.) [m]
4.25 4.25 4.25 3.75 3.75 3.25
φ' = 30°
Installation depth (max.) [m]
5.00 5.00 5.00 5.00 5.00 5.00
φ' = 40°
Installation depth [m]

If infiltration system elements are to be installed for the storage of rainwater (retention or rainwater harvesting), additional
loads caused by the presence / rising of groundwater must be evaluated.

Vertical loads Traffic load Soil load Vertical load Angle of friction
The vertical load comprises the traffic load and soil pressure Load [kN/m²] Load [kN/m²] Load [kN/m²] The fill material used has a significant influence on the hori- of friction φ',the higher such a medium can be piled up. In
as described above. The sum of the two loads is therefore zontal load and therefore the load which the system element addition, the greater the angle of friction and thus the internal
dependent on the installation depth. This limits the maximum must withstand at the sides. The angle of friction φ' describes rigidity of the material, the lower the horizontal load. A high
permitted fill cover on top of the infiltration elements. the effective angle of internal friction of a material. The effect angle of friction also favours the distribution of the point load
of the angle of friction can be seen, for example, in a heap of into an evenly distributed load. Preference should therefore
a granular medium (e.g. sand or gravel). The greater the angle always be given to a filler material with a high angle of friction.

Material Loam Loam/sand mix Sand Gravel

Angle of friction φ' 15° – 25° 25° – 30° 30° – 35° 35° – 40°

Installation depth [m] Installation depth [m] Installation depth [m]

Vertical loads – overall evaluation


Load [kN/m²]
The approved long-term vertical load for the EcoBloc Inspect
with a lifetime of 50 years is 59 kN/m² including safety factor Installation
window
of 2.0. Some national standards and certficates like BBA in UK
use different calculation methods, see BBA certificates for GRAF
products. Both the approved vertical loads and the vertical Vertical load
loads actually present limit the installation window of the ditch approval
elements with the minimum and maximum installation depth.
The installation window for the infiltration tunnel / twin infiltra-
tion tunnel can be calculated in the same way.

Installation depth [m]

14 Otto Graf GmbH Otto Graf GmbH 15


EcoBloc stormwater
management system

16 Otto Graf GmbH Otto Graf GmbH 17


EcoBloc stormwater
management system

Various applications DIB


t Fully integrated shaft Lorry-bearing up to 60 tons
2 6
2 .1-5 The Vario 800 flex shaft system (page 26) The EcoBloc Inspect flex has a heavy-du-
3
Stormwater management ▸ EcoBloc System

Stormwater management ▸ EcoBloc System


Rainwater infiltration Z-4

no.
can be directly installed in an EcoBloc ty lorry-bearing capacity of 60 tons with
er
tifi c a tio

n
infiltration or infiltration/attenuation
3 an 800 mm (2' 7.5") earth covering.

c
Stormwater attenuation system. The connection surfaces of the
3 Rainwater harvesting inspection channels in the Vario 800 flex
shaft system are accurately matched to
the EcoBloc system.
15/5200

High pressure jetting possible Easy to inspect


EcoBloc Inspect flex can easily resist The standard inspection channel allows
high pressure jetting. the entire infiltration/attenuation
system to be monitored effectively.
The EcoBloc Inspect flex allows access
by commercially available inspection
cameras. This has been confirmed by
several independent testing authorities.

Optimum connection positions


Optimum connection positions ensure
full use of infiltration ditch volume.

High storage volume Service life of over 50 years Easy to install Up to 97 % reservoir volume Installation depth of up GRAF EcoBloc Configurator
GRAF infiltration modules have three A durable product design ensures sus- The modules are fitted simply, at speed The EcoBloc light has a gross volume of to 5 metres (16' 4.8") Please ask your GRAF sales consultant
times the storage volume of a standard tainability. The EcoBloc system and the and in various ways. They can be in- 225 litres (59.4 US gal.) and a reservoir Even under very heavy loads, GRAF for your login account information to the
gravel infiltration ditch. Two modules Vario 800 flex shaft system is designed stalled without heavy machinery – one volume of 219 litres (57.9 US gal.). With a EcoBloc Inspect flex modules can be GRAF EcoBloc Configurator.
therefore take the place of around for a service life of over 50 years. EcoBloc Inspect flex module weighs just reservoir volume in excess up to 97 %, it installed at a depth of up to 5 metres
1300 kg (1,4 tons) of gravel or a 50 m 8 kg (17.6 lbs), even only 7 kg (15.4 lbs) is a market-leading product. The EcoBloc (16' 4.8"). This means that up to 14
(164') drainage pipe. Since you don‘t for one EcoBloc light variants maxx and Inspect flex still offer layers are possible. Please consult GRAF
have to excavate so much soil and a reservoir coefficient of 96 % despite when the installation depth is greater
enjoy great value for money compa- their high load-bearing capacity. than 5 metres.
red with a standard gravel infiltra-
tion ditch, the GRAF modules save
you hard-earned cash!

18 Otto Graf GmbH Otto Graf GmbH 19


The EcoBloc system at a glance

E OF
S T H E VOLUM
E CH
LD 3 TIM VEL DIT
CAN HO NTIONAL GRA
E
A CONV
Stormwater management ▸ EcoBloc System

Stormwater management ▸ EcoBloc System


Infiltration system Infiltration system Shaft Shaft accessories
body body accessories

EcoBloc Inspect flex Deaeration end, geotextile, Vario 800 flex, type 1 Telescopic dome shaft
Page 22 and connectors Page 26 pedestrian loading
Page 23 Page 27

Mini Maxi

Infiltrate and store rainwater EcoBloc Inspect flex Telescopic dome shaft
with EcoBloc Inspect flex base plate vehicle loading
Vario 800 flex, type 2 max. load 3.5 t
Page 22 Page 26
GRAF TV Page 27
www.graf.info/v215
EcoBloc Inspect flex
end plates
Page 22
Telescopic dome shaft

Application and logistics lorry bearing


Page 27

Eco-friendly product – green logistics


up to EcoBloc maxx
Vario 800 flex,

610 m³/Truck
Page 22
base/cover set
One lorry can transport up to 2700 EcoBloc Page 26
   EcoBloc maxx
light modules. That corresponds to a volume end plates
of 610 m³ (161,145 US gal.). This reduces Page 22
carbon emissions during transport by 85 % ! Infiltration inlet module
DN 600 (24")
Page 27
EcoBloc maxx
base plate
Page 22
Infiltration connecting piece
1000 DN 600 (24")
EcoBloc light Page 27
end plates
Page 23

EcoBloc light
Infiltration filter strainer
Page 23
DN 600 (24")
Page 27

EcoBloc
adaptor plate
Page 23

EcoBloc light
base plate Choke drain
1. Stackable 2. Easy installation 3. Ready pack 1 DN 100 (4"),
Page 23
pack 2 DN 150 (6"),
To save space during transport, the The EcoBloc base plate forms the The side faces are sealed with EcoBloc pack 3 floating choke
EcoBloc maxx and EcoBloc light modules foundations of each EcoBloc system. end plates. The EcoBloc system can drains
are stacked into each other. This Up to 13 EcoBloc modules can be fitted be adapted to match individual Page 27
minimizes transport costs, storage space on one base plate. requirements.
in stock and CO2 emissions.

20 Otto Graf GmbH Otto Graf GmbH 21


EcoBloc system
Modules

EcoBloc Inspect flex EcoBloc maxx EcoBloc light EcoBloc System accessories
Stormwater management ▸ EcoBloc System

Stormwater management ▸ EcoBloc System


l Lorry-bearing 60 tons/HS-25 l Lorry-bearing l L orry-bearing 12 tons
l 150 m³ (39,600 US gal.)/Truck 40 tons/HS-20 l 610 m³ (161,145 US gal.)/
l Inspectable l 410 m³ (108,310 US gal.)/Truck Truck
l High pressure jetting possible
EcoBloc connectors
For horizontal connection
Load  Load  Load  Order no. 402015 Set 10 units
Logistics  Logistics  Logistics  Order no. 402018 Set 25 units
Order no. 402020 Set 50 units
DIB
t
6
Order no. 402025 Set 200 units
-52
2.1
Z-4
no.

er
tifi c a tio
n
c

15/5200

EcoBloc Inspect flex EcoBloc maxx EcoBloc light


DN 100 (4") / 150 (6") / 200 (8") connecting surfaces Connecting surfaces on EcoBloc maxx end plates Connecting surfaces on EcoBloc light end plates
Deaeration end
Volume Length Width Height Weight Colour Order no. Volume Length Width Height Weight Colour Order no. Volume Length Width Height Weight Colour Order no. DN 100 (4")
205 l 800 mm 800 mm 320 mm 8 kg 225 l 800 mm 800 mm 350 mm 9 kg 225 l 800 mm 800 mm 350 mm 7 kg Order no. 369017
grey 402005 black 402200 green 402300
(54.2 US gal.) ( 2' 7.5") ( 2' 7.5") (12.6") (17.6 lbs) (59.4 US gal.) ( 2' 7.5") ( 2' 7.5") (13.8") (19.8 lbs) (59.4 US gal.) ( 2' 7.5") ( 2' 7.5") (13.8") (15.4 lbs)

Webcode G4107 Webcode G4108 Webcode G4109

EcoBloc adaptor plate


DN 300 (12") / DN 400 (16") / DN 500 (20")
EcoBloc Inspect flex base plate EcoBloc maxx base plate EcoBloc light base plate Order no. 402033
Forms the foundation of the EcoBloc Inspect flex system Forms the foundation of the EcoBloc maxx system Forms the foundation of the EcoBloc light system

Volume Length Width Height Weight Colour Order no. Volume Length Width Height Weight Colour Order no. Volume Length Width Height Weight Colour Order no.

25 l 800 mm 800 mm 40 mm 4 kg 25 l 800 mm 800 mm 40 mm 4 kg 25 l 800 mm 800 mm 40 mm 4 kg


grey 402006 black 402201 green 402301
(6.6 US gal.) ( 2' 7.5") ( 2' 7.5") (1.6") (8.8 lbs) (6.6 US gal.) ( 2' 7.5") ( 2' 7.5") (1.6") (8.8 lbs) (6.6 US gal.) ( 2' 7.5") ( 2' 7.5") (1.6") (8.8 lbs)

GRAF-Tex geotextile
size of 2.50 x 2.50 m (8' 2.4" x 8' 2.4")
Order no. 231006
EcoBloc Inspect flex end plates EcoBloc maxx end plates EcoBloc light end plates
The front ends of an EcoBloc The outside surface of an EcoBloc The outside surface of an EcoBloc
Inspect flex system are sealed by end plates with maxx system is sealed by end plates with contact light system is sealed by end plates with contact Sold by the metre, roll width 5 m (16' 4.8")
DN 100 (4") / 150 (6") / 200 (8") contact surfaces surfaces DN 100 (4") / 150 (6") / 200 (8") / 250 (10") surfaces DN 100 (4") / 150 (6") / 200 (8") / 250 (10") Order no. 231002

Item Colour Order no. Item Colour Order no. Item Colour Order no.
Sold by the metre, roll width 2,5 m (8' 2.4")
EcoBloc Inspect flex end plates EcoBloc maxx end plates EcoBloc light end plates Order no. 231007
grey 402002 black 402203 green 402303
(Set 2 units) (Set 2 units) (Set 2 units)

22 Otto Graf GmbH Otto Graf GmbH 23


EcoBloc system
Vario 800 flex shaft

Flexible use Easy to inspect Lorry-bearing up to 60 tons


Stormwater management ▸ Vario 800 flex shaft

Stormwater management ▸ Vario 800 flex shaft


clear width of 600 mm (1' 11")
The Vario 800 shaft provides easy The Vario 800 shaft allows easy access The GRAF Vario 800 shaft has a heavy-
access to all EcoBloc modules. It can to the EcoBloc system by commercially duty lorry-bearing capacity of 60 tons
be used in many different ways: available inspection cameras. This has with an 800 mm (2' 7.5") earth covering.
been confirmed by several independent The fibreglass reinforced material gives
3 As an inspection shaft
testing authorities. the shaft extra strength.
3 As an inlet shaft
3 As a filter shaft
3 As a flow control shaft

No additional excavation Connection surfaces up to Wide access Can be positioned in any


The Vario 800 flex shaft system can be DN 400 (16") The Vario 800 is terminated at the top location
directly installed in an EcoBloc infiltrati- The Vario 800 comes with DN 200 (8"), by GRAF telescopic dome shafts. With a The dimensions of the Vario 800 shaft
on or detention system. The connection DN 300 (12") and DN 400 (16") connec- clear width of 600 mm, it gives easy ac- enable free positioning within the
surfaces of the inspection channels in tion surfaces. The optional, freely rotat- cess to the shaft. The base of the shaft EcoBloc system. The corner position
the Vario 800 flex shaft system are accu- ing inlet module can be connected to itself is 800 x 800 mm (2' 7.5") x (2' 7.5") enables the connection of large pipe
clear width of 600 mm (1' 11") rately matched to the EcoBloc system. pipes of sizes DN 150 (6"), DN 200 (8"), in size, providing sufficient space for all diameters of up to DN 400 (16") on the
DN 250 (10") and DN 300 (12"). possible applications. two side panels. The central position
offers ideal access to the inspection
camera from all directions. Using the
optional inlet module, a connection of
Adjustable

Inclinable
up to DN 300 (12") can be made with a
freely defined angle.

Alignment of inspection channels


Can be rotated 360° No tools required The inspection channels allow complete Access is normally via the end face DN tem and the two DN 200 (8") inlets. The
checking and rinsing of the entire infil- 200 (8") connections of the Vario 800 open internal structure of the EcoBloc
tration ditch. The inspection channels shafts. The inspection camera enters Inspect ditch elements permits very
must run parallel to the length of the through an inspection shaft. This is ide- good illumination, making the infiltra-
ditch and form a continuous tunnel. ally created with the Vario 800 shaft sys- tion system easier to inspect.

24 Otto Graf GmbH Otto Graf GmbH 25


Vario 800 flex shaft Accessories

Vario 800 flex, type 1 Shaft components


Stormwater management ▸ Vario 800 flex shaft

shaft body for one or more layer of EcoBloc system


Infiltration filter strainer DN 600 (24") Infiltration inlet module DN 600 (24")
Volume Length Width Height Weight Colour Order no. Made entirely from stainless steel, Incl. profile seal for telescopic dome shaft;

Stormwater management ▸ Accessories


mesh width 0.75 mm (0.03") DN 150 (6")/ DN 200 (8")/ DN 250 (10")/ DN 300 (12") connections
230 l 800 mm 800 mm 355 mm 16 kg
grey 450050 Order no. 340523 Order no. 330360
(60.7 US gal.) (2' 7.5") (2' 7.5") (1' 2") (35.3 lbs)

Webcode G9303

Vario 800 flex, type 2


Infiltration connecting piece 1000 DN 600 (24") Infiltration connecting piece 1000 DN 600 (24")
shaft body for two or more layer of EcoBloc system
With DN 200 (8") contact surface, incl. profile seal, With DN 200 (8") pipe connections, incl. profile seal,
Volume Length Width Height Weight Colour Order no. length 1000 mm (3' 3.3"), 750 mm (2' 5.5"), 500 mm ( 1' 7.7") length 1000 mm (3' 3.3"), 750 mm (2' 5.5"), 500 mm ( 1' 7.7")
Order no. 371015 Order no. 371016
420 l 800 mm 800 mm 660 mm 27 kg
grey 450051
(113.5 US gal.) (2' 7.5") (2' 7.5") (2' 2") (59.5 lbs)

Vario 800 film cover – PE Vario 800 film cover – PVC


Vario 800 flex, base/cover set Fitted film for optimum welding Fitted film for optimum PVC packaging
base- and cover for Vario 800 flex shaft of Vario shafts – material PE-LD 3 mm (0.1") of Vario shafts – material PVC 3 mm (0.1")
Order no. 450505 Order no. 450508
Item Colour Order no.

set consisting out of Vario


grey 450052
base- and cover plate

Retention accessories
Choke drain 1 DN 100 (4") Choke drain 2 DN 150 (6")
Includes emergency overflow, connector seal DN 100 (4") Includes emergency overflow, connector seal DN 150 (6")
and PE-HD pipe for film welding; adjustable discharge and PE-HD pipe for film welding; discharge
1.0 l (0.3 US gal.); 2.0 l (0.5 US gal.); 5.0 l (1,3 US gal.) adjustable from 2.0 l (0.5 US gal.) to 16 l (4.2 US gal.)/s
and 6.5 l (1.7 US gal.)/s
Order no. 369005 Order no. 369006

Choke drain pack 3 floating choke drains


Includes emergency overflow and PE-HD pipe for film
welding; discharge adjustable from 0.05 l (0.01 US gal.)
to 2 l (0.5 US gal.)/s
Order no. 369007

Tank Covers

Mini telescopic dome shaft Maxi telescopic dome shaft


Suitable for pedestrian loading, Suitable for pedestrian loading,
height adjustable from 140 – 340 mm (5.5" – 13.4") height adjustable from 140 – 440 mm (5.5" – 17.3")
1. Stackable 2. Easy installation 3. Ready Order no. 371010 Order no. 371011
To save space during transport and Groups of four wall elements are GRAF accessory components can now be
storage, the parts of the Vario 800 are connected in a few simple steps and added to the Vario 800 shaft as required. Cover and compen-
stacked into each other. This minimizes without tools to form a single height unit sating ring to be
provided on site
transport costs and CO2 emissions. of the Vario 800. The height can be easily
adjusted to the EcoBloc tank depth. A Cast iron telescopic dome shaft Telescopic dome shaft lorry
shaft cover and base plate complete the Suitable for vehicle loading, Suitable for lorry-bearing loading,
element. height adjustable from 140 – 440 mm (5.5" – 17.3") height adjustable from 140 – 440 mm (5.5" – 17.3")
Order no. 371020 Order no. 371021

26 Otto Graf GmbH Otto Graf GmbH 27


Technical data sheet
Stormwater management ▸ EcoBloc System

Stormwater management ▸ EcoBloc System


Infiltration module Vario 800 flex type 1 / type 2 EcoBloc Inspect flex EcoBloc maxx EcoBloc flex / maxx EcoBloc light EcoBloc flex / light
Gross volume 230 l (60.7 US gal.) / 420 l (113.5 US gal.) 205 l (54.2 US gal.) 225 l (59.4 US gal.) A+B 225 l (59.4 US gal.) A+C
Net volume 195 l (51.5 US gal.) 217 l (57.3 US gal.) D+E 219 l (57.9 US gal.) D+F
Storage coefficient 100 % 96 % 96 % 96 % 97 % 96 – 97 %
Inspectable • • • •
High pressure jetting possible • • • •
Load
Short-term max. 100 kN/m² max. 100 kN/m² max. 100 kN/m² max. 85 kN/m² max. 75 kN/m² max. 53 kN/m²
Load
Long-term max. 59 kN/m² max. 59 kN/m² max. 59 kN/m² max. 50 kN/m² max. 41 kN/m² max. 31 kN/m²
min. earth covering 250 mm (9.8") 250 mm (9.8") 250 mm (9.8") 500 mm ( 1' 7.7") 250 mm (9.8") 250 mm (9.8")
max. earth covering 2750 mm (9') 2750 mm (9') 2750 mm (9') 2000 mm ( 6' 6.7") 1750 mm (5' 8.9") 1250 mm (4' 1.2")
Without traffic load
max. installation depth 5000 mm (16' 4.8") 5000 mm (16' 4.8") 5000 mm (16' 4.8") 5000 mm (16' 4.8") 4000 mm (13' 1.4") 4000 mm (13' 1.4")
max. number of layers 14 14 13 12 10 10
min. earth covering 250 mm (9.8") 250 mm (9.8") 250 mm (9.8") 500 mm ( 1' 7.7") 500 mm (1' 7.7") 500 mm (1' 7.7")
max. earth covering 2750 mm (9') 2750 mm (9') 2750 mm (9') 2000 mm ( 6' 6.7") 1750 mm ( 5' 8.9") 1250 mm (4' 1.2")
Vehicle
max. installation depth 5000 mm (16' 4.8") 5000 mm (16' 4.8") 5000 mm (16' 4.8") 5000 mm (16' 4.8") 4000 mm (13' 1.4") 4000 mm (13' 1.4")
max. number of layers 14 14 13 12 9 9
min. earth covering 500 mm ( 1' 7.7") 500 mm ( 1' 7.7") 500 mm ( 1' 7.7") 800 mm (2' 7.5") 800 mm ( 2' 7.5") 800 mm ( 2' 7.5")
max. earth covering 2750 mm (9') 2750 mm (9') 2750 mm (9') 2000 mm ( 6' 6.7") 1750 mm ( 5' 8.9") 1250 mm (4' 1.2")
Lorry 12/H-10/H-15
max. installation depth 5000 mm (16' 4.8") 5000 mm (16' 4.8") 5000 mm (16' 4.8") 5000 mm (16' 4.8") 4000 mm (13' 1.4") 4000 mm (13' 1.4")
max. number of layers 13 13 12 12 9 9
min. earth covering 500 mm ( 1' 7.7") 500 mm ( 1' 7.7") 500 mm ( 1' 7.7") 800 mm (2' 7.5")
max. earth covering 2500 mm ( 8' 2.4") 2500 mm ( 8' 2.4") 2500 mm ( 8' 2.4") 1750 mm ( 5' 8.9")
Lorry 30 ground level
max. installation depth 5000 mm (16' 4.8") 5000 mm (16' 4.8") 5000 mm (16' 4.8") 5000 mm (16' 4.8")
max. number of layers 13 13 12 11 min. – max.
earth covering
min. earth covering 500 mm ( 1' 7.7") 500 mm ( 1' 7.7") 800 mm (2' 7.5") 800 mm (2' 7.5") max. instal-
max. earth covering 2250 mm ( 7' 4.5") 2250 mm ( 7' 4.5") 2250 mm ( 7' 4.5") 1500 mm ( 4' 11") lation depth
Lorry 40/HS-20 max. number
max. installation depth 5000 mm (16' 4.8") 5000 mm (16' 4.8") 5000 mm (16' 4.8") 5000 mm (16' 4.8") EcoBloc
of layers
max. number of layers 13 13 11 11
min. earth covering 800 mm (2' 7.5") 800 mm (2' 7.5")
min. 1 m (3' 3.3")
max. earth covering 2000 mm ( 6' 6.7") 2000 mm ( 6' 6.7")
Lorry 60/HS-25 max. groundwater
max. installation depth 5000 mm (16' 4.8") 5000 mm (16' 4.8")
max. number of layers 13 13

Connections
DN 100 (4") • • • • •
DN 150 (6") • • • • •
DN 200 (8") • • • • • •
DN 250 (10") • • • •
DN 300 (12") • • 1),2) • 1),2) • 1),2) • 1),2) • 1),2)
DN 400 (16") • • 1),2) • 1),2) • 1),2) • 1),2) • 1),2)
DN 500 (20") • 2) • 2) • 2) • 2) • 2)
Measurements
Length 800 mm ( 2' 7.5") 800 mm ( 2' 7.5") 800 mm ( 2' 7.5") 800 mm ( 2' 7.5") 800 mm ( 2' 7.5") 800 mm ( 2' 7.5")
Width 800 mm ( 2' 7.5") 800 mm ( 2' 7.5") 800 mm ( 2' 7.5") 800 mm ( 2' 7.5") 800 mm ( 2' 7.5") 800 mm ( 2' 7.5")
Height 320 mm (1' 0.6") / 660 mm (2' 2.0") 320 mm (1' 0.6") 350 mm (1' 1.8") 750 mm (2' 5.5") 350 mm (1' 1.8") 750 mm (2' 5.5")
Weight 16 kg (35.3 lbs) / 27 kg (59.5 lbs) 8 kg (17.6 lbs) 9 kg (19.8 lbs) 7 kg (15.4 lbs)

1)  2) 
Optionally available with Vario shaft Optionally available with adaptor plates

28 Otto Graf GmbH Otto Graf GmbH 29


Infiltration
with EcoBloc maxx
Stormwater management ▸ EcoBloc System

Stormwater management ▸ EcoBloc System


1 Telescopic dome shaft 2 Infiltration inlet 3 Infiltration filter 4 Vario 800 flex, type 2 5 EcoBloc maxx 6 Deaeration end
module DN 600 (24") strainer • DN 100 (4")
• For separate
ventilation
• For installation
in green spaces

Page 23

7 Infiltration connecting
• Choice of pedestrian, • Freely rotatable for optimum • Stainless steel filter • Optimally aligned to • Lorry-bearing 40 tons/HS-20
car or HGV loading alignment to connecting line (mesh width 0.75 mm (0.03") EcoBloc Inspect flex • 410 m³ (108,310 US gal.)/Truck piece 1000 DN 600 (24")
• Connections up to DN 300 (12") • Reliably filters out • Wide range of possible • For greater
contamination shaft solutions installation
• Connections up to DN 400 (16") depths

Page 27 Page 27 Page 27 Page 26 Page 22 Page 27

30 Otto Graf GmbH Otto Graf GmbH 31


Swale infiltration Retention and rainwater harvesting
with EcoBloc light with EcoBloc Inspect flex and maxx
Stormwater management ▸ EcoBloc System

Stormwater management ▸ EcoBloc System


1 Telescopic filter 2 Vario 800 flex, type 1 3 EcoBloc light 1 Telescopic dome 2 Vario 800 flex, type 2 3 EcoBloc maxx
shaft 600 shaft lorry

• Choice of pedestrian, • Optimally aligned to • Lorry-bearing 12 tons • Lorry-bearing up to 60 tons • Optimally aligned to • Lorry-bearing 40 tons/HS-20
car or HGV loading EcoBloc Inspect flex • 610 m³ (161,145 US gal.)/Truck • Cover and compensating EcoBloc Inspect flex • 410 m³ (108,310 US gal.)/Truck
• Wide range of possible ring to be provided on site • Wide range of possible
shaft solutions shaft solutions
• Connections up to DN 400 (16") • Connections up to DN 400 (16")

Upon request Page 26 Page 23 Page 27 Page 26 Page 22

4 Deaeration end 4 EcoBloc Inspect flex 5 Choke drain 6 Submersible pump

• DN 100 (4") • Lorry-bearing 60 tons/HS-25 • Available from 0.05 l (0.01 US You can find pumps and other
• For separate ventilation • 150 m³ (39,600 US gal.)/Truck gal.) to 16 l (4.2 US gal.)/s products for rainwater harvest-
• For installation in green • Inspectable • Optimised for use in the Vario ing in our catalogue, "Rainwater
spaces • High pressure jetting possible 800 shaft harvesting solutions"

Page 23 Page 22 Page 27

32 Otto Graf GmbH Otto Graf GmbH 33


Firefighting water Rainwater harvesting
with EcoBloc Inspect flex with EcoBloc Inspect flex and light
Stormwater management ▸ EcoBloc System

Stormwater management ▸ EcoBloc System


1 Telescopic dome 2 Infiltration inlet 3 Vario 800 flex, type 2 1 Telescopic dome shaft 2 Infiltration inlet 3 Vario 800 flex, type 2
shaft lorry module DN 600 (24") module DN 600 (24")

l L orry-bearing up to 60 tons • Freely rotatable for optimum • Optimally aligned to • Choice of pedestrian, • Freely rotatable for optimum • Optimally aligned to
l Cover and compensating alignment to connecting line EcoBloc Inspect flex car or HGV loading alignment to connecting line EcoBloc Inspect flex
ring to be provided on site • Connections up to DN 300 (12") • Wide range of possible • Connections up to DN 300 (12") • Wide range of possible
shaft solutions shaft solutions
• Connections up to DN 400 (16") • Connections up to DN 400 (16")

Page 27 Page 27 Page 26 Page 27 Page 27 Page 26

4 EcoBloc Inspect flex 5 Firefighting water 6 Deaeration end 4 EcoBloc light 5 EcoBloc Inspect flex 6 Submersible pump
accessories

• Lorry-bearing 60 tons/HS-25 • Suction connection and • DN 100 (4") • Lorry-bearing 12 tons • Lorry-bearing 60 tons/HS-25 You can find pumps and other
• 150 m³ (39,600 US gal.)/Truck ventilation integrated in • For separate ventilation • 610 m³ (161,145 US gal.)/ • 150 m³ (39,600 US gal.)/Truck products for rainwater harvest-
• Inspectable the shaft • For installation in green Truck • Inspectable ing in our catalogue, "Rainwater
• High pressure jetting possible • High-quality stainless steel spaces • High pressure jetting possible harvesting solutions"
components

Page 22 Upon request Page 23 Page 23 Page 22

34 Otto Graf GmbH Otto Graf GmbH 35


Infiltration Tunnel / twin

36 Otto Graf GmbH Otto Graf GmbH 37


Infiltration Tunnel / twin
The logistical miracle – can be laid in rows
Stormwater management ▸ Infiltration Tunnel / twin

Stormwater management ▸ Infiltration Tunnel / twin


Easy installation 300 l Volume Lorry-bearing up to 60 tons
The GRAF Infiltration Tunnels are laid The compact dimensions com- In order to enable the free arrangement of sur-
in lines and can be flexibly adapted to bined with a storage coefficient faces above it, the Infiltration Tunnel features
specific conditions and to the individual of 100 % result in a useful vol- long-term resistance with 59 kN/m² (Infiltration
storage volume requested. The installa- 15/5200 ume of 300 l (79 US gal.). Tunnel twin 35 kN/m²) and is therefore lorry-
tion of the modules is easy, quick and bearing.
variable. The installation is possible
without heavy equipment, as one Infil-
tration Tunnel only weighs 11 gram
(24.3 lbs). The tunnel modules are
simply stuck together in one line and AT-15-7439/2009 100 % storage volume
equipped with 2 end plates per line.
The typical shape of the Infiltration
Tunnel enables complete utilisation of
the available volume for the temporary
storage of rainwater.

Infiltration Tunnel twin –


Twice the volume with the
same space requirement
Upon request, the Infiltration Tunnel twin
600 litres (158 US gal.) offers volume
through the connection of two identical
Infiltration Tunnel modules.

Connections up to DN 300 (12")


Large infiltration volumes require large
pipe diameters. For the GRAF Infiltration
Tunnel, this is not a problem: each end
plate features connections in the sizes DN
100 (4"), 150 (6"), 200 (8") and 300 (12").
Up to 12,000 litres infiltration
In addition, connections in the sizes DN
volume per pallet 100 (4") and 200 (8") are provided on the
Thanks to its special design, the GRAF upper surface for the connection of a ven-
Infiltration Tunnel can be stacked easily. tilation system or an inspection opening.
Consequently, the shipment of up to 40
Infiltration Tunnels on one pallet saves
High infiltration performance Installation depth of over
considerable transport and storage
costs. The ditch elements are placed directly 4 metres (13' 1.5")
upon an even layer of gravel. The sides The GRAF Infiltration Tunnel can be
are then covered with geotextile and the installed at a depth of up to 4.25 metres
end faces are closed using end plates. (13' 11"), even under heavy loads. The
l up to 500,000 litres per lorry This installation and the side slats maximum installation depth for the Infil-
ensure a permanent high infiltration tration Tunnel twin is 2.5 metres (8' 2.4").
l 975 items per 40'' HC container performance.

38 Otto Graf GmbH Otto Graf GmbH 39


Infiltration Tunnel / twin
Ditch system
Stormwater management ▸ Infiltration Tunnel / twin

Stormwater management ▸ Infiltration Tunnel / twin


Infiltration ditch Infiltration ditch Shaft Shaft accessories
body body accessories

Infiltration Tunnel Deaeration end, geotextile, Infiltration shaft DN 400 (16") Telescopic dome shaft
Page 42 and connectors Page 50 pedestrian loading
Page 42 Page 51

Mini Maxi

Telescopic dome shaft


vehicle loading
max. load 3.5 t
Page 51

Telescopic dome shaft


lorry bearing
Page 51
Infiltration Tunnel twin Infiltration Tunnel/twin Infiltration shaft DN 600 (24")
Page 42 end plate Page 51
Page 42

Infiltration connecting piece


DN 400 (16")
Page 50

Infiltration connecting piece


1000 DN 600 (24")
Page 51

Filter strainer
DN 400 (16") / DN 600 (24")
Page 50 / 51

Infiltration choke drain


DN 100 (4") / DN 150 (6")
Page 50 / 51

40 Otto Graf GmbH Otto Graf GmbH 41


Infiltration Tunnel / twin
Stormwater management ▸ Infiltration Tunnel / twin

Stormwater management ▸ Infiltration Tunnel / twin


Infiltration module Infiltration Tunnel lorry Infiltration Tunnel twin car
Gross / net volume 300 litres (79 US gal.) 600 litres (158 US gal.)
Infiltration Tunnel lorry Load
Volume Length Width Height Weight Colour Order no. Short-term max. 100 kN/m² max. 75 kN/m²
Load
Long-term max. 59 kN/m² max. 35 kN/m²
300 l 1160 mm 800 mm 510 mm 11 kg
black 230010 min. earth covering 250 mm (9.8") 250 mm (9.8")
(79 US gal.) (45.7") (31.5") (20") (24.4 lbs)
Without traffic load max. earth covering 3750 mm (12' 3.2") 1500 mm (4' 10.3")
Webcode G4103 max. installation depth 4250 mm (13' 11.3") 2500 mm (8' 2.4")
min. earth covering 250 mm (9.8") 500 mm (16.7")
Vehicle max. earth covering 3500 mm (11' 5.4") 1500 mm (4' 10.3")
max. installation depth 4000 mm (13' 1.5") 2500 mm (8' 2.4")
min. earth covering 500 mm (16.7")
Lorry 12/H-10/H-15 max. earth covering 3250 mm (10' 7.5")
max. installation depth 3750 mm (12' 3.6") ground level
min. earth covering 500 mm (16.7") min. – max.
max.
Lorry 30 max. earth covering 2750 mm (10' 7.6") earth covering
instal-
Infiltration Tunnel twin car max. installation depth 3250 mm (10' 8") lation max. number
Consisting of two tunnels and 1 set of click-bolt connectors min. earth covering 500 mm (16.7") depth Tunnel of layers
Lorry 40/HS-20 max. earth covering 2500 mm (8' 2")
Volume Length Width Height Weight Colour Order no.
max. installation depth 3000 mm (9' 10.1") min. 1 m (3' 3.3")
600 l 1160 mm 800 mm 1020 mm 22 kg min. earth covering 750 mm (29.5")
black 410130 max. groundwater
(158 US gal.) (45.7") (31.5") (40") (48.8 lbs)
Lorry 60/HS-25 max. earth covering 1750 mm (5' 8.5")
Webcode G4104 max. installation depth 2250 mm (7' 4.6")

Connections on front
DN 100 (4") 2x 4x
DN 150 (6") 1x 2x
DN 200 (8") 1x 2x
DN 300 (12") 1x 2x

Connections on top
End plate for Infiltration Tunnel / twin DN 100 (4") 1x 1x
DN 200 (8") 1x 1x
Item Colour Order no.
Measurements
End plates (Set of 2 units) black 231004
Length 1160 mm (45.7"), 1220 mm (48") (incl. end plates)
Width 800 mm ( 2' 7.5")
Height 510 mm (24") 1020 mm (48")
Weight approx. 11 kilos (24.2 lbs) approx. 2 x 11 kilos (2 x 24.2 lbs)

Infiltration Tunnel / twin accessories

GRAF-Tex geotextile
Inspection end Deaeration end For one Infiltration Tunnel
DN 200 (8") DN 100 (4") Size of 2.50 x 2.50 m (8' 2.4" x 8' 2.4") 250 mm 500 mm 750 mm
Order no. 340527 Order no. 369017 Order no. 231006 (9.8") (16.7") (29.5")

Sold by the metre, roll width 5 m (16' 4.8")


GRAF click-bolt connectors
Connector for Infiltration Order no. 231002
Tunnel twin (set of 6 for one
Infiltration Tunnel twin car) Sold by the metre, roll width 2,5 m (8' 2.4")
Order no. 410094 Order no. 231007 Vehicle loading Lorry-bearing 40 t Lorry-bearing 60 t

42 Otto Graf GmbH Otto Graf GmbH 43


Infiltration Tunnel / twin
Areas of application
Stormwater management ▸ Infiltration Tunnel / twin

Stormwater management ▸ Infiltration Tunnel / twin


Ditch infiltration with Infiltration Tunnel 1 Telescopic dome shaft 2 Infiltration shaft DN 400 (16")

• Choice of pedestrian, • 2 x DN 150 (6")


car or HGV loading • For connections of up
to DN 150 (6")

Page 51 Page 50

3 Infiltration Tunnel 4 Inspection end

• The logistical miracle – • DN 200 (8")


can be laid in rows

Page 42 Page 42

Combined rainwater harvesting and infiltration with Infiltration Tunnel

1 Rainwater harvesting 2 Infiltration Tunnel

You can find more


information about
our Carat S Rain-
water tank in our
catalogue, "Rain- • The logistical miracle –
water harvesting can be laid in rows
solutions"
Page 42

3 Inspection end 4 Deaeration end

• DN 200 (8") • DN 100 (4")


• For separate ventilation

Page 42 Page 42

44 Otto Graf GmbH Otto Graf GmbH 45


Infiltration Tunnel / twin
Areas of application
Stormwater management ▸ Infiltration Tunnel / twin

Stormwater management ▸ Infiltration Tunnel / twin


Ditch infiltration with Infiltration Tunnel twin

1 Telescopic dome shaft 2 Infiltration shaft DN 600 (24")

• Choice of pedestrian, • 2 x DN 150 (6")


car or HGV loading • For connections of up
to DN 150 (6")
Page 51 Page 51

3 Infiltration Tunnel twin 4 Deaeration end

• Twice the volume with the • DN 100 (4")


same space requirement • For separate ventilation

Page 42 Page 42

Combined wastewater treatment and infiltration with Infiltration Tunnel

1 Wastewater treatment 2 Infiltration Tunnel

You can find


more information
aboutwastewa-
ter treatment in
our catalogue, • The logistical miracle –
"Wastewater can be laid in rows
Treatment
Solutions" Page 42

3 Inspection end 4 Deaeration end

• DN 200 (8") • DN 100 (4")


• For separate ventilation

Page 42 Page 42

46 Otto Graf GmbH Otto Graf GmbH 47


Infiltration and Multi shaft system

Stormwater management ▸ Infiltration shaft system


Infiltration shaft Infiltration shaft Universal indus- Universal Infiltration Settling
Filters and shafts Vario 800 flex
system DN 400 system DN 600 trial external 3 filter 3 external filter shaft filter shaft

800 x 800 mm Ø 400 mm Ø 600 mm Ø 600 mm Ø 400 mm Ø 600 mm Ø 400 mm


Dimension
(31.4" x 31.4") (15.7") (23.6") (23.6") (15.7") (23.6") (15.7")

Loading class

• • • • • • •

• • • • • • •

• • • • ○ ○ ○

Connection options / flow rates


DN 100 (4") – 5.5 l/sec. 5.5 l/sec. – 5.5 l/sec. 5.5 l/sec. 5.5 l/sec.
DN 150 (6") – 16 l/sec. 16 l/sec. 16 l/sec. 16 l/sec. 16 l/sec. 16 l/sec.
DN 200 (8") 29.5 l/sec. 29 5 l/sec. 29.5 l/sec. 29.5 l/sec. – – –
DN 250 (10") – – 55 l/sec. – – – –
DN 300 (12") 99 l/sec. – 99 l/sec. – – – –
DN 400 (16") 175 l/sec. – – – – – –
Filter type B A or C B B A A and C D

Function of shafts
Filter shaft • • • • • • •
Sedimentation shaft – – – – – • •
Inspection shaft • • • – – – –
Choke shaft • • • – – – –
Pump shaft • • • – – – –
Catalogue page Page 26 Page 50 Page 51 Page 52 Page 52 Page 53 Page 53

Filter type Material Mesh width Soil volume Note

Filter type A
PP 0.35 mm (0.01") 15 l (4 US gal.) with lifting device
Filter basket DN 400 (16")

Filter type B
Infiltration filter Stainless steel 0.75 mm (0.03") 25 l (6.6 US gal.) with lifting device
strainer DN 600 (24")

Filter type C galvanised < 0.50 mm (0.02") Coarse filter with lifting device
20 l (5.3 US gal.)
Telescopic filter basket PP 0.35 mm (0.01") Fine filter

Filter type D
PP 0.35 mm (0.01") 17 l (4.5 US gal.) with lifting device
Settling filter basket

48 Otto Graf GmbH Otto Graf GmbH 49


Infiltration shaft system Infiltration shaft system
DN 400 (16") DN 600 (24")
Stormwater management ▸ Infiltration shaft system

Stormwater management ▸ Infiltration shaft system


Covers Covers
Telescopic dome shaft 400 Telescopic dome shaft 400
Telescopic dome shaft Mini Telescopic dome shaft cast iron
With PE cover, suitable for With cast iron cover, suitable for
With PE cover, suitable for With cast iron cover, suitable for
pedestrian loading, vehicle loading max. load 3.5 t,
pedestrian loading, vehicle loading max. load 3.5 t,
colour: grass green colour: black
colour: grass green colour: black
Order no. 340053 Order no. 340054
Order no. 371010 Order no. 371020

Telescopic dome shaft 400 Telescopic filter shaft 400 Telescopic dome shaft Maxi Telescopic dome shaft lorry
With cast iron cover, With slotted cast iron cover, suitable With PE cover, suitable for For common concrete rings,
lorry-bearing max. load 60 t, for vehicle loading max. load 3.5 t, pedestrian loading, lorry-bearing max. load 60 t,
colour: black incl. coarse filter insert and colour: grass green colour: black
Order no. 340049 fine filter basket (0.35 mm (0.01") Order no. 371011 Order no. 371021
mesh width), colour: black
Order no. 340126

Individual components Individual components

Infiltration inlet module DN 600 (24") Infiltration filter strainer DN 600 (24")
Infiltration inlet module DN 400 (16") Infiltration filter basket Incl. profile seal for telescopic dome shaft; Made entirely from stainless
Incl. profile seal for telescopic dome shaft; DN 400 (16") DN 150 (6")/DN 200 (8")/DN 250 (10")/DN 300 steel, mesh width 0.75 mm (0.03")
DN 150 (6")/DN 200 (8") connections Mesh width 0.35 mm (0.01") (12") connections
Order no. 330339 Order no. 340524 Order no. 330360 Order no. 340523

Infiltration connecting piece Infiltration connecting piece


Infiltration connecting piece DN 400 (16") 1000 DN 600 (24") 1000 DN 600 (24")
To produce greater installation depths, With DN 200 (8") contact surface, With DN 200 (8") pipe connections,
effective length: 500 mm (19.7"), can be incl. profile seal, length 1000 mm (3' 3.3"), incl. profile seal, length 1000 mm (3' 3.3"),
shortened to 250 mm (9.8") 750 mm (2' 5.5"), 500 mm ( 1' 7.7") 750 mm (2' 5.5"), 500 mm ( 1' 7.7")
Order no. 330341 Order no.371015 Order no. 371016

Retention accessories Retention accessories


Infiltration distributor module DN 400 (16") Infiltration choke drain Infiltration distributor module DN 600 (24") Infiltration choke drain
Incl. profile seal for infiltration connecting Connection DN 100 (4"); Incl. profile seal for infiltration connecting Connection DN 150 (6"); delayed
piece and/or inlet module; 2 x DN 150 (6") delayed drain of 1.0 (0.3 US gal.)/sec. piece and/or inlet module; 2 x DN 150 (6") drain of 2 l (0.5 US gal)/sec.
connections; mounting surface for connec- up to 6.5 l (1.7 US gal.)/sec. connections; mounting surface for connections up to 16 l (4.2 US gal.)/sec.
tions of up to DN 150 (6") of up to DN 150 (6")
Order no. 330340 Order no. 330547 Order no. 330361 Order no. 330598

Webcode G9301 Webcode G9302

50 Otto Graf GmbH Otto Graf GmbH 51


Universal filter Infiltration filter shaft / settling
filter shaft

Universal filter 3 external Infiltration filter shaft


Stormwater management ▸ Filter technology

Stormwater management ▸ Filter technology


l 1 00 % water yield therefore ideal l 3-stage cleaning process
for smaller roof areas 1 Coarse filter insert
1
l Filter insert mesh width 2 Fine filter basket 0.35 mm (0.01")

0.35 mm (0.01") mesh width


l Continuously variable installation 3 Sedimentation zone

depth of 600 mm – 1050 mm (22.4 – l Retains contaminants which may affect 2

41.3") using the telescopic dome shaft Inlet infiltration performance


l Lockable, childproof cover l Ideal as a courtyard inlet structure or a
l Flush with ground level trough-trench overflow element
1
l Minimal height offset 270 mm (10.6") l Suitable for vehicle loading with cast
between the inlet and outlet Dirty water iron cover 3.5 t 4
l Also suitable for infiltration and pond to the sewer l Continuously variable installation depth
2
systems Cleaned water of 570 – 1050 mm (22.4" – 41.3") using
l Maximum flow rate of 5.5 l/sec. with 3 3
to the tank telescopic dome shaft Ø 400 mm
connections DN 100 (4") and 16 l/sec. l Maximum flow rate of 5.5 l/sec. with DN
with DN 150 (6") 100 (4") and 16 l/sec. with DN 150 (6")
Connection dimensions Webcode G2205 l DN 100 (4") and DN 150 (6") connections Webcode G4401
1 Inlet 273 – 723 mm (10.7 – 28.5")
Universal filter 3 external 2 Outlet 544 – 944 mm (21.4 – 37.2") Infiltration filter shaft Infiltration connecting piece DN 400 (16") Connection dimensions
Suitable for pedestrian loading 3 Emergency overflow 273 – 723 mm (10.7 – 28.5") Suitable for vehicle loading To produce greater installation depths, 4 Outlet 245 – 725 mm (9.6 – 28.5")
Order no. 340020 All dimensions from middle of connection to ground level Order no. 340025 effective length: 500 mm (19.7"), can be
All dimensions from middle of connection to ground
shortened to 250 mm (9.8") level

Universal filter 3 external Infiltration connecting piece DN 400 (16") Replacement filter basket Order no. 330341
Suitable for vehicle loading To produce greater installation depths, Filter insert with practical
Order no. 340021 effective length: 500 mm (19.7"), can be lift-out device
shortened to 250 mm (9.8")
Order no. 330341 Order no. 340524

Universal industrial Settling filter shaft


filter 3 external l 3-stage cleaning process
1 Fine filter basket 0.35 mm (0.01")
l F or maximum flow rate of up to 29.5 l/sec.
mesh width)
l Continuously variable installation depth 2 Sedimentation zone
of 703–1270 mm (26.7– 50.0") using the 3 Immersion pipe as separator
telescopic dome shaft l Continuously variable installation
l Maximum flow rate of 16 l/sec. with con-
depth of 900– 1600 mm (2' 11.4"–5' 3")
nections DN 150 (6") and 29.5 l/sec. with
Inlet using telescopic dome shaft Ø 600 mm
DN 200 (8") Emergency l Pedestrian loading with plastic cover,
l Only 229 mm (9") height offset between overflow to
1
the sewer or suitable for vehicle loading with 4
the inlet and the outlet
cast iron cover 3.5 t 3
l Lockable childproof cover 1
3
Universal industrial filter 3 external 2 l Sealed to top edge of ground
2
Suitable for pedestrian loading Cleaned water l Maximum flow rate of 16 l/sec. with 5
to the tank or
Order no. 340050 for infiltration DN 150 (6")
l DN 150 (6") connections

Universal industrial filter 3 external Webcode G4402


Webcode G2202
Suitable for vehicle loading Settling filter shaft
Order no. 340051 pedestrian loading Infiltration connecting piece
Connection dimensions Order no. 340026 1000 DN 600 (24") Connection dimensions
Infiltration filter strainer DN 600 (24") 1 Inlet DN 150 (6") /200 (8") 395 – 962 mm (15.6 – 37.9") With DN 200 (8") contact surface, 4 Inlet 380–1080 mm (15 – 42.5")
Made entirely from stainless 2 Outlet DN 150 (6") 624 – 1191 mm (24.6 – 46.9") Settling filter shaft incl. profile seal, length 1000 mm (3' 5 Outlet 630–1330 mm (24.8 – 52.4")
steel, mesh width 0.75 mm (0.03") 3 Emergency overflow DN 150 (6") /200 (8") 395 – 962 mm (15.6 – 37.9") Suitable for vehicle loading 3.3"), 750 mm (2' 5.5"), 500 mm ( 1' 7.7")
All dimensions from middle of connection to ground
Order no. 340523 Order no. 340027 Order no.371015 level
All dimensions from middle of connection to ground level

52 Otto Graf GmbH Otto Graf GmbH 53


KLsepa.compact
PLING
Light fluid separator EG R AT ED SAM
INT NT
N N EC T ION POI
CO

Separator systems for light fluid liquids


class I + II
Stormwater management ▸ KLsepa.compact

Stormwater management ▸ KLsepa.compact


Illustration shows Saphir NS 3
Separators are needed wherever water Tank cover KLsepa.compact+ with coale-
is contaminated with oils and other light scence unit, integrated sampling
liquids. Separator systems are classified Optional sludge collector connection point
Expansion possible
according to NS (nominal size). When through optional sludge
you submit an enquiry for a separator collector
system, we calculate the NS you require
based on the EN 858 part 2. Operators
of the following facilities must ensure
that a suitable, functioning separator is
installed:
Car washes, workshops, fuel stations,
vehicle fleets, hazardous goods stores

Coalescence separator and fuel


separator integrated sampling
Coalescence unit
The KLsepa.compact+ separator systems connecting point
included with KLsepa.
are coalescence separators of class I. compact+ system
They feature an additional coalescence
unit that enables a much higher degree
of separation. The KLsepa.compact
separator systems are fuel separators
of class II. A fuel separator achieves a
degree of separation of less than 100 Warning sensors
mg residual oil per litre of water. With a
coalescence unit, this can be reduced to >> Optional: different
less than 5 mg/l. warning systems available

Tank covers GERMAN


DESIGN AND
>> on request ENGINEERING

EN 858-1
Dimensions Saphir Tank volume
NS DN Length Width Height Weight Oil Sludge Total
[l/s] [mm] [mm] [mm] [mm] [kg] [l] [l] [l]
3 150 1155 1155 1790 – 1990 80 300 300 770
(0.79 US gal./s) (6") (3' 9.5") (3' 9.5") (5' 11" – 6' 6.4") (176 lbs.) (79 US gal.) (79 US gal.) (203 US gal.)
3 150 1155 1155 2110 – 2310 110 500 400 1,100
(0.79 US gal./s) (6") (3' 9.5") (3' 9.5") (6' 11" – 7' 7") (243 lbs.) (132 US gal.) (105 US gal.) (290 US gal.)
3 150 1155 1155 2110 – 2310 110 300 600 1,080
(0.79 US gal./s) (6") (3' 9.5") (3' 9.5") (6' 11" – 7' 7") (243 lbs.) (79 US gal.) (158 US gal.) (288 US gal.)
6 150 1155 1155 2110 – 2310 110 300 600 1,080
(1.60 US gal./s) (6") (3' 9.5") (3' 9.5") (6' 11" – 7' 7") (243 lbs.) (79 US gal.) (158 US gal.) (288 US gal.)
Effectiveness according to EN 858 tested by TÜV Rheinland.

Dimensions Diamant Tank volume


NS DN Length Width Height Weight Oil Sludge Total
[l/s] [mm] [mm] [mm] [mm] [kg] [l] [l] [l]
In addition to easily separat drops of oil, To separate out these smaller droplets, As more oil flows in, the film becomes 6 150 2450 1150 1765 – 2055 165 500 1,300 2,210
a light fluid separator also contains very a coalition material is fitted before the thicker until it can no longer adhere to (1.60 US gal./s) (6") (8') (3' 9") (5' 9.5" – 6' 9") (364 lbs.) (132 US gal.) (343 US gal.) (584 US gal.)
fine oil droplets whose density is not suf- discharge to which the droplets stick and the material. Individual drops break off 10 150 2450 1150 1765 – 2055 165 500 1,300 2,210
ficiently different from water for them to form a oil film. the film, which are large enough to rise (2.64 US gal./s) (6") (8') (3' 9") (5' 9.5" – 6' 9") (364 lbs.) (132 US gal.) (343 US gal.) (584 US gal.)
rise to the surface in the available time. to the surface through difference in den- 10 200 2450 1400 2020 – 2310 250 660 2,000 3,330
These droplets therefore remain in the sity and be separated out. (2.64 US gal./s) (8") (8') (4' 7") (6' 7.5" – 7' 7") (551 lbs.) (174 US gal.) (528 US gal.) (880 US gal.)
outflowing water. 15 200 2450 1400 2020 – 2310 250 660 2,000 3,330
(3.96 US gal./s) (8") (8') (4' 7") (6' 7.5" – 7' 7") (551 lbs.) (174 US gal.) (528 US gal.) (880 US gal.)
Effectiveness according to EN 858 tested by TÜV Rheinland.

54 Otto Graf GmbH Otto Graf GmbH 55


Rainwater detention and retention Rainwater detention and retention
with limited outlet

Stormwater management ▸ Water detention and retention


Detention
Detention systems, i.e. rainwater deten- tion cistern. This amount accumulates in
tion, play an important role in the reduc- the detention cistern and is also drained
tion of hydraulic peaks and thus help re- off with the throttled runoff water after
limited outflow
lieve strain on the public sewer network, the rainfall event. The detention volume
particularly in new construction areas. is thus discharged and remains avail-

Flow rate in l/sec.


Detention systems usually consist of a able once more as a temporary storage
volume which is used for the temporary tank for the next rainfall event.
storage of rainwater in the event of
heavy rainfall, and a throttling device
to limit the draining runoff water. The Flow duration in hrs
rainwater is cleaned using a filter before Retention volume increases

it enters the detention volume in order


to avoid compromising the function of
the throttling device. The throttled flow 1. O
 utflow rate without throttle
of rainfall is fed into the sewer and the 2. Outflow rate with static throttle
excess amount is retained in the deten- 3. O
 utflow rate with dynamic throttle

Retention
The GRAF retention cistern is a combina- The retention cistern is designed such
tion of rainwater retention and rainwater that the rainwater first fills the usage
harvesting. The detention can be larger volume. When the useful volume is full,
if required. In this case, part of the the throttled outflow is activated and limited outflow
rainwater can also be used in addition the detention volume also becomes

Flow rate in l/sec.


to the required detention volume. For available for temporary storage. The
example, rainwater can be used for the detention mechanism with throttled
following applications: outflow in turn corresponds to a con-
• Watering gardens ventional retention system. Following
• Flushing toilets the rainfall event, the position of the Storage volume Flow duration in hrs
• Washing machines outflow prevents the detention cistern holds Retention volume increases
• Cleaning from being completely emptied, while
the usage volume remains in the tank !
1. Outflow rate without throttle
The use of rainwater means that up to
2. Outflow rate with static throttle
50 % of drinking water can be saved,
3. O utflow rate with dynamic throttle
and up to 85 % for commercial proper-
ties.

Detention Retention

Rainwater
detention

Rainwater
harvesting

56 Otto Graf GmbH Otto Graf GmbH 57


Carat S underground tank Carat S underground tank
Detention cistern Retention cistern
Stormwater management ▸ Detention Carat S

Stormwater management ▸ Retention Carat S


Floating Infiltration choke drain Floating Infiltration choke drain

Emergency overflow Emergency overflow


Rainwater
detention
Overflow siphon

to sewer
Rainwater
harvesting
calmed inflow

calmed inlet

to sewer

Figure shows Carat S detention cistern, tank cover on page 51 Webcode G4301 Figure shows Carat S retention cistern, tank cover on page 51 Webcode G4302

Rainwater harvesting solutions closed, no function Rainwater harvesting solutions closed, no function

For more information about our For more information about our

I1*

I1*
Carat S Rainwater tank please refer Carat S Rainwater tank please refer
I1

I1
to our brochure "Rainwater harvest- to our brochure "Rainwater harvest-
ing solutions" ing solutions"

Carat S choke drain Carat S choke drain


Htot

Htot
O1

O1
I2*

I2*
H

H
I2

I2
package detention / retention package detention / retention
0.05 – 2.0 l (0.01 – 0.5 US gal.)/sec, 0.05 – 2.0 l (0.01 – 0.5 US gal.)/sec,
DN 100 (4") connection, 3 m (9' 10.1") hose DN 100 (4") connection, 3 m (9' 10.1") hose
Order no. 369020 Order no. 369020

O2
W S W S
OUTFLO OUTFLO
HIGHER QUEST O2 HIGHER QUEST
ON RE ON RE
L L

Carat S underground tank detention cistern Carat S underground tank retention cistern
Detention Usage Height
Capacity Width W Length L Height Htot Height H Inlet I1 Inlet I2 Inlet I1* Inlet I2* Outlet O1 Outlet O2 Capacity Width W Length L Height H Inlet I1 Inlet I2 Inlet I1* Inlet I2* Outlet O1 Outlet O2
volume volume Htot
2,700 l 1565 mm 2080 mm 1690 mm 1400 mm 520 mm 1490 mm 245 mm 1955 mm 1530 mm 160 mm 3,750 l 1,500 l 2,250 l 1755 mm 2280 mm 2200 mm 1590 mm 520 mm 1680 mm 245 mm 1955 mm 2040 mm 160 mm
(700 US gal.) (5' 1.6") (6' 9.9") (5' 6.5") (4' 7.1") (20.5") (4' 10.7") (9.6") (6' 4.9") (5' 0.2") (6.3") (1,000 US gal.) (400 US gal.) (600 US gal.) (5' 9.0") (7' 5.8") (7' 2.6") (5' 2.6") (20.5") (5' 6.2") (9.6") (6' 4.9") (6' 8.3") (6.3")
3,750 l 1755 mm 2280 mm 2200 mm 1590 mm 520 mm 1680 mm 245 mm 2185 mm 2040 mm 160 mm 4,800 l 2,000 l 2,800 l 1985 mm 2280 mm 2430 mm 1820 mm 520 mm 1910 mm 245 mm 2185 mm 2270 mm 160 mm
(1,000 US gal.) (5' 9.0") (7' 5.8") (7' 2.6") (5' 2.6") (20.5") (5' 6.2") (9.6") (7' 2.0") (6' 8.3") (6.3") (1,250 US gal.) (520 US gal.) (730 US gal.) (6' 6.2") (7' 5.7") (7' 11.7") (5' 11.7") (20.5") (6' 3.2") (9.6") (7' 2.0") (7' 5.4") (6.3")
4,800 l 1985 mm 2280 mm 2430 mm 1820 mm 520 mm 1910 mm 245 mm 2465 mm 2270 mm 160 mm 6,500 l 3,000 l 3,500 l 2190 mm 2390 mm 2710 mm 2100 mm 520 mm 2190 mm 245 mm 2465 mm 2550 mm 160 mm
(1,250 US gal.) (6' 6.2") (7' 5.7") (7' 11.7") (5' 11.7") (20.5") (6' 3.2") (9.6") (8' 1.0") (7' 5.4") (6.3") (1,700 US gal.) (800 US gal.) (900 US gal.) (7' 2.2") (7' 10.0") (8' 10.7") (6' 10.7") (20.5") (7' 2.2") (9.6") (8' 1.0") (8' 4.4") (6.3")
6,500 l 2190 mm 2390 mm 2710 mm 2100 mm 520 mm 2190 mm 245 mm 1920 mm 2550 mm 160 mm
(1,700 US gal.) (7' 2.2") (7' 10.0") (8' 10.7") (6' 10.7") (20.5") (7' 2.2") (9.6") (6' 3.6") (8' 4.4") (6.3")

Please refer to the installation instructions for groundwater installation and loading capacity. Please refer to the installation instructions for groundwater installation and loading capacity.

58 Otto Graf GmbH Otto Graf GmbH 59


Platin flat tank Platin flat tank
Detention cistern Retention cistern TION
N (DETEN
E D IS T RIBUTIO BE INDIVIDU-
UM AN
THE VOL GE VOLUME) C O YOUR
LU M E / USA D A CCO RDING T
VO URE
NUFACT ATIONS.
ALLY MA SPECIFIC
Stormwater management ▸ Detention Platin

Stormwater management ▸ Retention Platin


Emergency overflow

Floating Infiltration
choke drain Rainwater
detention

Emergency overflow

Floating Infiltration Rainwater


choke drain harvesting

to sewer Sewer connection


calmed inlet

Figure shows Platin detention cistern, tank cover on page 51 Webcode G4303 Figure shows Platin retention cistern, tank cover on page 51 Webcode G4304

Rainwater harvesting solutions Rainwater harvesting solutions


Volume Detention volume Order no. Volume Detention volume Usage volume Order no.
For more information about our Platin flat For more information about our Platin flat
1,500 l 1,500 l 3,000 l 3,000 l 2,000 l
390300 tank please refer to our brochure "Rain- 390312 tank please refer to our brochure "Rain-
(400 US gal.) (400 US gal.) (800 US gal.) (800 US gal.) (520 US gal.)
3,000 l 3,000 l water harvesting solutions" 5,000 l 4,500 l 3,000 l water harvesting solutions"
390301 390315
(800 US gal.) (800 US gal.) (1,350 US gal.) (1,200 US gal.) (800 US gal.)
closed, no function closed, no function
5,000 l 5,000 l 7,500 l 6,000 l 4,000 l
390302 390324
(1,350 US gal.) (1,350 US gal.) (2,000 US gal.) (1,600 US gal.) (1,200 US gal.)
7,500 l 7,500 l 10.000 l 1) 6,000 l 4,000 l
390305 390321
I1

I1
(2,000 US gal.) (2,000 US gal.) (2,650 US gal.) (1,600 US gal.) (1,200 US gal.)
10.000 l 1) 10.000 l 1)
390304 Scope of supply: Platin tank, floating choke drain and hose.
(2,650 US gal.) (2,650 US gal.)

O1
Htot

Htot
O1

Cover has to be ordered seperately, page 51


Scope of supply: Platin tank, floating choke drain and hose.
H
I2

H
I2
Cover has to be ordered seperately, page 51

O2 O2

L L

Platin flat tank detention cistern Platin flat tank retention cistern
For combined rainwater detention and rainwater harvesting, including retention accessories

Volume Width W Length L Height Htot Height H Inlet I1 Inlet I2 Outlet O1 Outlet O2 Volume Width W Length L Height Htot Height H Inlet I1 Inlet I2 Outlet O1 Outlet O2

1,500 l 1250 mm 2100 mm 1015 mm 700 mm 185 mm 830 mm 925 mm 90 mm 3,000 l 2100 mm 2450 mm 1050 mm 735 mm 185 mm 865 mm 960 mm 90 mm
(400 US gal.) (4' 1.1") (6' 10.7") (3' 3.9") (27.6") (7.3") (32.7") (36.4") (3.5") (800 US gal.) (6' 10.7") (8' 0.5") (3' 5.3") (28.9") (7.3") (34.1") (37.8") (3.5")
3,000 l 2100 mm 2450 mm 1050 mm 735 mm 185 mm 865 mm 960 mm 90 mm 5,000 l 2300 mm 2890 mm 1265 mm 950 mm 185 mm 1080 mm 1175 mm 90 mm
(800 US gal.) (6' 10.7") (8' 0.5") (3' 5.3") (28.9") (7.3") (34.1") (37.8") (3.5") (1,350 US gal.) (7' 6.5") (9' 5.8") (4' 1.8") (37.") (7.3") (3' 6.5") (3' 10.3") (3.5")
5,000 l 2300 mm 2890 mm 1265 mm 950 mm 185 mm 1080 mm 1175 mm 90 mm 7,500 l 2250 mm 3600 mm 1565 mm 1250 mm 185 mm 1380 mm 1475 mm 90 mm
(1,350 US gal.) (7' 6.5") (9' 5.8") (4' 1.8") (37.") (7.3") (3' 6.5") (3' 10.3") (3.5") (2,000 US gal.) (7' 4.6") (11' 9.7") (5' 1.6") (4' 1.1") (7.3") (4' 6.3") (4' 10.1") (3.5")
7,500 l 2250 mm 3600 mm 1565 mm 1250 mm 185 mm 1380 mm 1475 mm 90 mm Further sizes upon request!
(2,000 US gal.) (7' 4.6") (11' 9.7") (5' 1.6") (4' 1.1") (7.3") (4' 6.3") (4' 10.1") (3.5")

Please refer to the installation instructions for groundwater installation and loading capacity. Please refer to the installation instructions for groundwater installation and loading capacity. 1)
Set consisting of two Platin flat tanks

60 Otto Graf GmbH Otto Graf GmbH 61


Carat XL underground tank
detention / retention cistern

Carat XL underground tank DN 200 (8")

Suitable for vehicle / lorry 12 t

I1*
l Suitable for HGV loading up to 12 t DN 150 (6")

I1
l Can be mounted in groundwater DN 150 (6")
Stormwater management ▸ Carat XL

Stormwater management ▸ Carat XL


l 
Lower weight than concrete and steel DN 150 (6")
l 
Various connection surfaces DN 100 (4") / 150 (6") DN 100 (4")

l 
Investment security thanks to a 15 year warranty

O1
l 
Can be used as detention or retention cistern

Htot

I2*

I2
O2
TENTION
T R IB U TION (DE DIVIDU- L
UME DIS AN BE IN OUR
THE VOL GE VOLUME) C
DN 100 (4")
OY
E / U S A C O RDING T
VOLUM
U F A C T U R E D AC S.
ALLY MA
N ATION
SPECIFIC

B
Figure shows 10,000 l (2,640 US gal.) Figure shows tank without cover. The total
tank with cast iron telescopic dome installation height results from the total tank
Larger connection fittings upon request shaft suitable for vehicle loading height (Htot) plus the telescopic dome shaft
(page 51).

Carat XL underground tank detention cistern Carat XL underground tank detention and retention cistern
Total volume / Detention volume Weight Order no. Volume Width W Length L Height Htot Height H Inlet I1 Inlet I2 Inlet I1* Inlet I2* Outlet O1 Outlet O2

8,500 l 380 kg 8,500 l 2040 mm 3500 mm 2695 mm 2085 mm 805 mm 1890 mm 435 mm 2625 mm 2585 mm 110 mm
370504
(2,242 US gal.) (838 lbs) (2,250 US gal.) (6' 8.3") (11' 5.8") (8' 10.1") (6' 10.1") (31.7") (6' 2.4") (17.1") (8' 7.4") (8' 5.8") (4.3")
10,000 l 456 kg 10,000 l 2240 mm 3520 mm 2895 mm 2285 mm 805 mm 2090 mm 435 mm 2625 mm 2785 mm 110 mm
370505
(2,640 US gal.) (1.005 lbs) (2,650 US gal.) (7' 4.2") (11' 6.6") (9' 6.0") (7' 6.0") (31.7") (6' 10.3") (17.1") (8' 7.4") (9' 1.7") (4.3")

Webcode G4307

Carat XL underground tank retention cistern Technical data


Total volume Detention volume Usage volume Order no. max. axle load: 8t
max. total weight: 12 t
8,500 l 3,500 l 5,000 l Earth covering with loading capacity: 800 – 1500 mm (2' 7.5" – 4' 11")
370523
(2,242 US gal.) (923 US gal.) (1320 US gal.)
Groundwater stability: up to the middle of the tank
10,000 l 4,000 l 6,000 l
370525 Earth covering with groundwater installation: 800 – 1500 mm (2' 7.5"–4' 11")
(2,640 US gal.) (1055 US gal.) (1583 US gal.)
Connection options: DN 100 (4") / DN 150 (6"), DN 200 (8") on top
Webcode G4308 Tank dome inner Ø: 650 mm (25.6")

Scope of supply: Carat XL underground rainwater tank with Maxi tank dome, choke drain and hose

62 Otto Graf GmbH Otto Graf GmbH 63


Carat XXL underground tank
ND
NTION A
up to 122,000 litres (32,230 US gal.) IL A B L E AS DETE ID U A LLY
A R AT X XL AVA . C A N B E INDIV UR
C RN YO
N CISTE DING TO
RETENTIO TUERED ACCOR .
A C N S
MANUF SPECIFIC
ATIO
DN 200 (8")
Carat XXL underground tank DN 300 (12")
connection on
Suitable for vehicle/lorry 40 t end face upon
request DN 150 (6")

I1*
Suitable for HGV loading up to 40 t

I1
l DN 150 (6")
l Can be mounted in groundwater DN 150 (6")
Stormwater management ▸ Carat XXL

Stormwater management ▸ Carat XXL


DN 100 (4")
l 
Lower weight than concrete and steel
l 
Various connection surfaces

O1
HTOT
DN 100 (4")/150 (6")/200 (8")

I2*

H
l 
Available with DN 300 (12") connection

I2
as an option Carat XXL available with a second
l 
Available with a second tank dome tank dome as an option
as an option O2
l 
122,000 litres (32,230 US gal.) L
Volume possible DN 100 (4")
l Investment security thanks to a

15 year warranty

Webcode G1104
Carat XXL available with DN 300
(12") connection as an option

B
Figure shows tank with Maxi tank dome with-
out cover (Mini tank dome available as an op-
tion). The total installation height results from
the total tank height (Htot) plus the telescopic
dome shaft (page 51).
Figure shows Carat XXL 46,000 l (12,150 US gal.)
with Telescopic dome shaft lorry

Carat XXL underground rainwater tank Carat XXL underground rainwater tank
Order no. Order no.
Capacity Tank dome inner Ø Weight Capacity Width W Length L Height Htot Height H Inlet I1 Inlet I2 Inlet I1* Inlet I2* Outlet O1 Outlet O2
detention retention
16,000 l (4,250 US gal.) 650 mm (25.6") 805 kg (1.770 lbs) 380500 380520 16,000 l 2500 mm 4660 mm 3160 mm 2550 mm 800 mm 2360 mm 435 mm 2725 mm 3070 mm 90 mm
22,000* (5.800 US gal.) 650 mm (25.6") 1015 kg (2.250 lbs) 380501 380521 (4,250 US gal.) (8' 2.4") (15' 3.4") (10' 4.4") (8' 4.4") (2' 7.5") ( 7' 9.0") (17.1") (8' 11.3") (10' 0.8") (3.5")
26,000 (6.900 US gal.) 650 mm (25.6") 1150 kg (2.550 lbs) 380502 380522 22,000 l* 2500 mm 6145 mm 3160 mm 2550 mm 800 mm 2360 mm 435 mm 2725 mm 3070 mm 90 mm
32,000* (8,450 US gal.) 650 mm (25.6") 1360 kg (3.000 lbs) 380503 380523 (5.800 US gal.) (8' 2.4") (20' 1.9") (10' 4.4") (8' 4.4") (2' 7.5") ( 7' 9.0") (17.1") (8' 11.3") (10' 0.8") (3.5")
36,000 (9,500 US gal.) 650 mm (25.6") 1495 kg (3.300 lbs) 380504 380524 26,000 l 2500 mm 7045 mm 3160 mm 2550 mm 800 mm 2360 mm 435 mm 2725 mm 3070 mm 90 mm
42,000* (11,100 US gal.) 650 mm (25.6") 1705 kg (3.750 lbs) 380505 380525 (6.900 US gal.) (8' 2.4") (23' 1.3") (10' 4.4") (8' 4.4") (2' 7.5") ( 7' 9.0") (17.1") (8' 11.3") (10' 0.8") (3.5")

46,000 (12,150 US gal.) 650 mm (25.6") 1840 kg (4.050 lbs) 380506 380526 32,000 l* 2500 mm 8530 mm 3160 mm 2550 mm 800 mm 2360 mm 435 mm 2725 mm 3070 mm 90 mm
(8,450 US gal.) (8' 2.4") (27' 11.8") (10' 4.4") (8' 4.4") (2' 7.5") ( 7' 9.0") (17.1") (8' 11.3") (10' 0.8") (3.5")
52,000* (13,750 US gal.) 650 mm (25.6") 2050 kg (4.500 lbs) 380507 380527
56,000 (14,800 US gal.) 650 mm (25.6") 2185 kg (4.800 lbs) 380508 380528 36,000 l 2500 mm 9430 mm 3160 mm 2550 mm 800 mm 2360 mm 435 mm 2725 mm 3070 mm 90 mm
(9,500 US gal.) (8' 2.4") (30' 11.3") (10' 4.4") (8' 4.4") (2' 7.5") ( 7' 9.0") (17.1") (8' 11.3") (10' 0.8") (3.5")
62,000* (16,400 US gal.) 650 mm (25.6") 2395 kg (5.280lbs) 380509 380529
42,000 l* 2500 mm 10915 mm 3160 mm 2550 mm 800 mm 2360 mm 435 mm 2725 mm 3070 mm 90 mm
66,000 (17,450 US gal.) 650 mm (25.6") 2530 kg (5.600 lbs) 380510 380530
(11,100 US gal.) (8' 2.4") (35' 9.7") (10' 4.4") (8' 4.4") (2' 7.5") ( 7' 9.0") (17.1") (8' 11.3") (10' 0.8") (3.5")
72,000* (19,000 US gal.) 650 mm (25.6") 2740 kg (6.050 lbs) 380511 380531
46,000 l 2500 mm 11815 mm 3160 mm 2550 mm 800 mm 2360 mm 435 mm 2725 mm 3070 mm 90 mm
76,000 (20,100 US gal.) 650 mm (25.6") 2875 kg (6.350 lbs) 380512 380532
(12,150 US gal.) (8' 2.4") (38' 9.1") (10' 4.4") (8' 4.4") (2' 7.5") ( 7' 9.0") (17.1") (8' 11.3") (10' 0.8") (3.5")
up to 122,000 litres (32,230 US gal.) upon request *with a second tank dome 52,000 l* 2500 mm 13300 mm 3160 mm 2550 mm 800 mm 2360 mm 435 mm 2725 mm 3070 mm 90 mm
(13,750 US gal.) (8' 2.4") (43' 7.6") (10' 4.4") (8' 4.4") (2' 7.5") ( 7' 9.0") (17.1") (8' 11.3") (10' 0.8") (3.5")
Scope of supply: Carat XL underground rainwater tank with Maxi tank dome, choke drain and hose
56,000 l 2500 mm 14200 mm 3160 mm 2550 mm 800 mm 2360 mm 435 mm 2725 mm 3070 mm 90 mm
(14,800 US gal.) (8' 2.4") (46' 7.1") (10' 4.4") (8' 4.4") (2' 7.5") ( 7' 9.0") (17.1") (8' 11.3") (10' 0.8") (3.5")
62,000 l* 2500 mm 15685 mm 3160 mm 2550 mm 800 mm 2360 mm 435 mm 2725 mm 3070 mm 90 mm
(16,400 US gal.) (8' 2.4") (51' 5.5") (10' 4.4") (8' 4.4") (2' 7.5") ( 7' 9.0") (17.1") (8' 11.3") (10' 0.8") (3.5")
Technical data 66,000 l 2500 mm 16585 mm 3160 mm 2550 mm 800 mm 2360 mm 435 mm 2725 mm 3070 mm 90 mm
max. axle load: 8t (17,450 US gal.) (8' 2.4") (54' 4.9") (10' 4.4") (8' 4.4") (2' 7.5") ( 7' 9.0") (17.1") (8' 11.3") (10' 0.8") (3.5")
max. total weight: 3.5 t with cast iron cover, 40 t with telescopic dome shaft lorry 72,000 l* 2500 mm 18070 mm 3160 mm 2550 mm 800 mm 2360 mm 435 mm 2725 mm 3070 mm 90 mm
Earth covering with loading capacity: 800 – 1500 mm (2' 7.5" – 4' 11") (19,000 US gal.) (8' 2.4") (59' 3.4") (10' 4.4") (8' 4.4") (2' 7.5") ( 7' 9.0") (17.1") (8' 11.3") (10' 0.8") (3.5")
Groundwater stability: up to the middle of the tank 76,000 l 2500 mm 18970 mm 3160 mm 2550 mm 800 mm 2360 mm 435 mm 2725 mm 3070 mm 90 mm
Earth covering with groundwater installation: 800 – 1500 mm (2' 7.5" – 4' 11") (20,100 US gal.) (8' 2.4") (62' 2.8") (10' 4.4") (8' 4.4") (2' 7.5") ( 7' 9.0") (17.1") (8' 11.3") (10' 0.8") (3.5")

Connection options: DN 100 (4") – DN 200 (8") up to 122,000 litres (32,230 US gal.) upon request *with a second tank dome

64 Otto Graf GmbH Otto Graf GmbH 65


Herkules detention cistern Herkules Infiltration tank

The detention cistern with unequalled The Infiltration tank with unequalled

Stormwater management ▸ Infiltration Herkules


Stormwater management ▸ Retention Herkules

value for money. Thanks to its patented value for money. Thanks to its patented
design, the transport of the Herkules In- design, the transport of the Herkules In-
filtration tank is very easy. The two tank filtration tank is very easy. The two tank
halves can be assembled on site, and halves can be assembled on site, and
US US
the patented quick connection system 0 7 the patented quick connection system 7
89 90
7 78
enables easy, tool-free installation in 58 enables easy, tool-free installation in 58
n n
Pa t e Pa t e

t
just a few minutes. By using the inter- just a few minutes. By using the inter-
connecting pipe sets, the system can be connecting pipe sets, the system can be
extended at will. Patent no. in Europe extended at will. Patent no. in Europe
0870877 and USA no. 587807 0870877 and USA no. 5878907

Technical data Technical data


Volume 1,600 litres (422 US gal.)
Volume 1,600 litres (422 US gal.)
S
LITRE Max Ø 1350 mm (53")
Max Ø 1350 mm (53") 1,600 S GAL.)
(422 U
Height 1600 mm (63")
Height 1600 mm (63")
Herkules detention cistern  bre-glass reinforced PP
fi
 bre-glass reinforced PP
fi Material Herkules Infiltration tank
Material 1,600 litres (422 US gal.) (UV stable and 100 % recyclable)
(UV stable and 100% recyclable)
without support pipe Including support pipe
Weight approx. 60 kg (132 lbs) Weight approx. 60 kg (132 lbs)
Order no. 320001 Order no. 200201
Connec- each 2 x DN 70 (2.8"), DN 100 (4") Connec- each 2 x DN 70 (2.8"), DN 100 (4")
tions and DN 200 (8") Webcode G1301 tions and DN 200 (8") Webcode G1309

Accessories for Herkules detention cistern and Herkules Infiltration tank

Cut-out tool (with pilot drill) Tank dome GRAF-Tex geotextile


DN 70 (2.8")  Order no. 202002 (with telescopic end 1 m For one Herkules Infiltration Tank
DN 100 (4")  Order no. 202003 (3.3') to be cut on demand) Order no. 369015
DN 200 (8")  Order no. 322026
Interconnecting pipe set Material sold by the metre,
(without cut-out tool) roll width 5 m (15.2')
Support pipe for Herkules tank
DN 70 (2.8")  Order no. 202029 required for underground assembly Order no. 231002
DN 100 (4")  Order no. 202028 DN 150 (6")  Order no. 322014

Practical advantages of Herkules Further application possibilities


Ease of transport Easy to Several tanks can
Each half of the Herkules-Tank only weighs 30 kg (66 lbs). install be combined Rainwater harvesting
This allows ease of transport and manual installation. The Above ground Underground as a cellar tank
tank halves fit through any doorway (80 cm (31.5") width and above). solutions
You can find more
information about our
Herkules rainwater tank
and other products for
rainwater harvesting in
our catalogue, "Rainwa-
ter harvesting solutions"

66 Otto Graf GmbH Otto Graf GmbH 67


Wastewater Treatment Solutions 2023

Wastewater
Treatment
Solutions

Wastewater Treatment Systems


Septic Tanks
Cesspools
Infiltration
Separators

EN 960523
A43 – 2023

Wastewater treatment solutions


For more information about our RAINWATER HARVESTING
wastewater treatment solutions,
ask for our catalogue.

STORMWATER MANAGEMENT
Please note:
Information on all products and systems in this
brochure is subject to changes and errors.

Pictures and photographs are approximate only.

The applicable technical documentation for the


WASTEWATER TREATMENT SOLUTIONS
products shall control, which we will be happy to send
you on request.

All offers, deliveries and services are subject to our


general terms and conditions, which we will also be
happy to send you.
SEPARATORS

GRAF worldwide please visit


GARANTIA GARDEN PRODUCTS &
www.graf.info MULTI-PURPOSE CONTAINERS
Photo copyright: stock.adobe.com
© Alexandr_Ozerov (page 3)
GRAF UK Ltd © ps_42 (page 6)
© JWMD (page 28)
Otto Graf GmbH Regen House © benjaminnolte (page 49)
Kunststofferzeugnisse Tel.: +49 7641 589-0 Beaumont Road Phone: +44 1608 661-500
© Otto Graf GmbH/Order no. 960288/EN
Carl-Zeiss-Straße 2 – 6 Fax: +49 7641 589-50 Banbury, Oxfordshire Fax: +44 01295 211333
DE-79331 Teningen [email protected] UK-OX16 1RH [email protected]

You might also like