100% found this document useful (1 vote)
77 views

Vef Wiring Diagram

This document provides wiring diagrams for various VEF ventilation units. The diagrams show the connections for power supply, control interface, and external devices. Terminals are labeled for supply voltage, ground, control input, output signals, and cable colors. Specifications are given for voltage ranges, output current limits, and interface reference grounds.

Uploaded by

sermatronic 1
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
77 views

Vef Wiring Diagram

This document provides wiring diagrams for various VEF ventilation units. The diagrams show the connections for power supply, control interface, and external devices. Terminals are labeled for supply voltage, ground, control input, output signals, and cable colors. Specifications are given for voltage ranges, output current limits, and interface reference grounds.

Uploaded by

sermatronic 1
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Wiring Diagram

1 (2)

VEF

+10V
0-10V
GND

GND
0-10V
+10V

VEF + MTP 10/10K


VEF

+10V
0-10V
GND

GND
0-10V
+10V

VEF + MTP 20 3-Step


VEF

+10V
0-10V
GND

GND
0-10V
+10V

VEF + EC-Basic-H

VEF

+10V
0-10V
GND

GND
0-10V
+10V

Systemair UAB Linų st. 101, LT–20174 Ukmergė, LITHUANIA


Phone: +370 340 60165 Fax: +370 340 60166 -en_GB- A008
Wiring Diagram
2 (2)

VEF + EC-Basic-CO2

VEF

+10V
0-10V
GND

GND
0-10V
+10V

VEF + F251–14 EC

VEF

+10V
0-10V
GND

GND
0-10V
+10V

VEF + 392–14 EC / MONOLIT – EC


VEF

+10V
0-10V
GND
MONOLIT - EC

GND
0-10V
+10V

Supply connection, power supply, phase, see nameplate for BU Blue


L voltage range
BN Brown
Supply connection, power supply, neutral conductor, see BK Black
N nameplate for voltage range
GND Ground
PE Ground connection
RD Red
Not used.
1 Tach output, open collector, 1 pulse per revolution, max = 10 YE Yellow
mA, SELV WH White
2 (-) Reference ground for control interface, SELV SC Signal cable
3 0-10 V / PWM control input, Ri=100 kΩ, SELV FC Fan cable
Fixed voltage output 10 VDC +/-3 %, max. 10 mA, short-
4 (+)
circuit-proof, power supply for ext. devices, SELV

Systemair UAB Linų st. 101, LT–20174 Ukmergė, LITHUANIA


Phone: +370 340 60165 Fax: +370 340 60166 -en_GB- A008