SmartComm Design v2.1

This document describes SmartComm Design v2.1, electrical installation sizing and simulation software. The software allows users to design single line diagrams, perform fault level calculations, select switchgear and conductors, and generate reports. Version 2.1 includes updates like added protection selectivity curves, improved GUI and report customization options. The software benefits customers by assisting with tasks like protection coordination analysis, bill of materials generation, and validating equipment selections.

Uploaded by

nagarajan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
311 views10 pages

SmartComm Design v2.1

This document describes SmartComm Design v2.1, electrical installation sizing and simulation software. The software allows users to design single line diagrams, perform fault level calculations, select switchgear and conductors, and generate reports. Version 2.1 includes updates like added protection selectivity curves, improved GUI and report customization options. The software benefits customers by assisting with tasks like protection coordination analysis, bill of materials generation, and validating equipment selections.

Uploaded by

nagarajan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

Electrical Installation Sizing and Simulation Software

[ Your Trusted Partner for designing Reliable Electrical Network ]


Presenting SmartComm Design v2.1
Design SLD

Fault Level
Calculation

Switchgear and
Conductor Selection

Project Report
Generation

Export to pdf,
autocad

And many more…


SmartComm Design v2.1 : Feature List

▪ Complete Power flow study


▪ Conductor sizing – LV Cable & BBT
considering Installation Method,
Correction factor
▪ Fault Calculation
- Symmetrical
- Unsymmetrical fault
▪ Voltage drop
▪ SCPD Selection
▪ Selectivity Check
What does SmartComm Design cover?

Earthing System Source Load Network Other factors


● MV/LV Transformer ● Motor ● Network requiring
● TN-C ● Diversity Factor
● Lighting reactive Power
● TN-T ● LV feeders ● Load Utilization factor
Compensation
● Generators ● General Additional correction at
● TT ● Network with ●
● Parallel operation ● Socket Harmonics sites
● IT
of Sources ● Various Installation &
● Coupled Source correction factors
SmartComm Design v2.1 : Customization options

Project details, Customer Name & Location


Customer Logo
Consultant Name
Customized Panel & Load Name
User defined Product Selection Option
Full Report/Specific Report
Export to pdf/AutoCAD
User defined Protection Settings
SmartComm Design v2.1 : Customization options
Branch Current Details

Project
Voltage Drop Details

Short Circuit Details

Report RCD Details


LV SCPD Details

covers Capacitor Bank Details

Distribution Busbar Details

Selectivity
SmartComm Design v2.1 : Selectivity Curves
Cable Protection

SCPD Selectivity Report

RCD Selectivity
What’s new in v2.1 ??
SmartComm Design v2.0 - Database updation - DZ1 Addition

SmartComm Design v2.1


to SQL - Curves for double
- Linking with the Circuit Breakers in
Centralized Server feeder
- GUI Improvement - All Product Database
- SLD Print Option updation
- Customized Load and - Breaker Selection
Panel Naming option Logic Reviewed
- Capacitor bank step-
size recommendation
Benefits to Customer

• Designing SLD • Curve Report Submission • Validating Right


• Fault Level Calculation • Alternate Product Switchgear Selection &
as per standards Selection Conductor Protection
• BOM & Project Report • Type-2 coordinated • Selectivity Report
Generation Product Selection Validation
• Selectivity Analysis • APFC Panel Design • Protection Settings

Panel
Consultant End Users
Builders