ADJUSTABLE POWER SUPPLY
EAN CODE : 3760244880024 SIMPLE AL 924A
PRACTICAL : Digital display of voltage and current.
PRECISE : Coarse and fine voltage adjustment.
- Adjustable current from 0 to 10A or 0 to 1A .
USEFUL : Automatic constant voltage or current
operation.
PROTECTED : Short circuit protection.
300 WATTS
0 - 30V 0 - 10A
Specifications
Voltage Other specifications
• Floating outputs on 4 mm safety terminals.
• Automatic constant voltage operation.
• Adjustable from 0 to 30V (0 to + or -5mV) with fine adjustment (about 2 Volts). • Safety : Class I, enhanced safety between mains input and outputs.
• Regulation : < 40mV for a load variation from 0 to 100%. Complies with EN 61010-1, overvoltage category II,
< 25mV for a 10% line variation. pollution degree 2.
• Ripple : < 3 mV peak to peak or 1 mV rms.
• Internal resistance: < 4 mΩ. • EMC : Complies with EN 61326-1, performance criteria B,
• Indicator : green LED for voltage regulation. and EN 55011, ISM Group I, Class B.
• Display : 14mm 3 digit LED digital voltmeter. • Input voltage : 230V ±10%, 50 / 60 Hz.
• Resolution : 100 mV. • Mains input : EEC socket with 2 poles + earth cable
• Power consumption : 620 VA.
Current • Dielectric strength : 2300V from input to output,
• Automatic constant current operation.
1350V from input to chassis.
• Two selectable current ranges : 10A or 1A.
• Adjustable from 0 to 10A or from 0 to 1A, depending on the selected range. • Outputs : safety terminals (VDE 0110 standard and BG certified),
• Regulation : < 10 mA for a 10% line charge. and safety inverted earth terminal.
< 20 mA for a load change from 0 to 100%. • Presentation : screen-printed polycarbonate front panel, metal
• Ripple : < 10 mA peak to peak or 3,5 mA rms. case, epoxy finish.
• Indicators : red LED for current regulation.
• Display : 14 mm 3 digit LED digital ammeter.
• Resolution : 10 mA on 1A range, 100 mA on 10A range
Protection
• Short circuit protection, by current regulation.
• Overtemperature protection, by fan, by thermal circuit-breaker and by relay
on the transformer.
• Transformer primary overcurrent protection, by fuse.
11 | www.elc.fr