AVR3AVR4IO
AVR3AVR4IO
INSTRUCTIONS FOR
AVR3 Series
Steam Heated Vaporizing Regulator
AVR4 Series
Electrically Heated Vaporizing Regulator
AVR4 Series
Certifications
KEMA 03ATEX2359
Page 1
1. Installation and Operation Instructions for
AVR3 Series Steam Heated Vaporizing Regulator
AVR4 Series Electrically Heated Vaporizing Regulator
Contents
I. Statement of Liability
II. Safety
III. Operating Conditions
IV. Installation - Figure 1
V. Maintenance
VI. Regulator Operation
VII. Voltage and Power Rating Configurations
VIII. Product Marking
I. Statement of Liability
II. Safety
Observe all safety rules when connecting or operating this device with any
electrical and/or pressure system.
The user should not assume that all safety measures are indicated in this
manual, or that other such measures may not be required.
Page 2
1. Installation and Operation Instructions for
AVR3 Series Steam Heated Vaporizing Regulator
AVR4 Series Electrically Heated Vaporizing Regulator
2. Install inlet (HP), outlet (LP) and, if applicable, auxiliary (AUX LP)
connections:
CAUTION - AVR3 and AVR4 regulators are marked with maximum rated inlet
pressure and regulated pressure range. Accessories such as gauges, relief
valves or special fittings may be assembled to the regulator and may have
lower rated pressures. Always observe the lowest pressure rating when
connecting accessories to the regulator or connecting the regulator to any
pressure source.
For external earthing or bonding a cable lug shall be used so that the
conductor is secured against loosening and twisting and that contact
pressure is permanently secured.
Loosen junction box cover setscrew (1/16" internal hex) and remove cover.
Page 3
1. Installation and Operation Instructions for
AVR3 Series Steam Heated Vaporizing Regulator
AVR4 Series Electrically Heated Vaporizing Regulator
Connect 0-250 VAC analog or non-auto ranging voltmeter across heater leads
(brown wires).
Apply AC power.
Voltage should drop when set point is reached and then cycle.
The approximate temperature set during installation does not account for
the mass flow or thermodynamic properties of the media or for
environmental conditions. The process temperature must be established
with the AVR4 installed and operating at desired inlet and outlet
pressures and with the media flowing at the desired rate.
Loosen junction box cover setscrew (1/16" internal hex) and remove cover.
Establish process media flow conditions.
Page 4
1. Installation and Operation Instructions for
AVR3 Series Steam Heated Vaporizing Regulator
AVR4 Series Electrically Heated Vaporizing Regulator
The media temperature of the AVR3 is controlled by the energy flow of the
steam supplied. The controllable variables are flow, temperature and
pressure.
The regulator is set at 0 psig and no flow at the factory. The process
outlet pressure should be set under actual inlet pressure and media flow
conditions.
Initiate flow -
Turn stem (1/8" internal hex) slowly clockwise (CW) to raise outlet
(LP) to desired pressure.
Page 5
1. Installation and Operation Instructions for
AVR3 Series Steam Heated Vaporizing Regulator
AVR4 Series Electrically Heated Vaporizing Regulator
V. Maintenance
AVR3 ONLY - Shutoff steam supply and allow unit to cool to safe handling
temperature.
AVR4 ONLY - Shutoff electrical power and allow unit to cool to safe
handling temperature.
Loosen and remove three (3) 3/8-16 bolts (9/16" hex) from heater collar.
Clean heat transfer threads with 5/8-24 UNF thread die and/or wire brush.
Test all connections for leakage before returning the unit to service.
Page 6
1. Installation and Operation Instructions for
AVR3 Series Steam Heated Vaporizing Regulator
AVR4 Series Electrically Heated Vaporizing Regulator
Loosen junction box cover setscrew (1/16" internal hex) and remove cover.
Loosen terminal block connections - two (2) 6-32 x 3/16" slotted head
screws and two (2) 6-32 x 1/4 male/female standoffs (1/4" hex).
Remove controller.
Before installing replacement units, verify that power rating and supply
voltage are correct.
Page 7
1. Installation and Operation Instructions for
AVR3 Series Steam Heated Vaporizing Regulator
AVR4 Series Electrically Heated Vaporizing Regulator
The effect can be hazardous when shutting down the inlet supply. Care
must be taken to maintain flow or vent the outlet when decreasing the
inlet pressure to protect against increases in outlet pressure.
3. Flow Curves -
4. Lockup (Creep) -
The lockup pressure is the rise in outlet pressure which occurs when flow
is reduced to zero while maintaining inlet pressure. This reflects the
force required to seal off the regulator. The lockup pressure for an AVR3
or AVR4 regulator with PCTFE seat is under 2 psi (13.8 kPa) with 1500 psig
(10.3 kPa) inlet. Other seat materials may result in higher lockup
pressures.
Page 8
1. Installation and Operation Instructions for
AVR3 Series Steam Heated Vaporizing Regulator
AVR4 Series Electrically Heated Vaporizing Regulator
Page 9
1. Installation and Operation Instructions for
AVR3 Series Steam Heated Vaporizing Regulator
AVR4 Series Electrically Heated Vaporizing Regulator
Page 10
1. Installation and Operation Instructions for
AVR3 Series Steam Heated Vaporizing Regulator
AVR4 Series Electrically Heated Vaporizing Regulator
The temperature controller units are designed to accommodate low (75F - 220F) and
high (215F - 380F) range applications. The unit is a completely encapsulated
component with a temperature adjustment control.
The Veriflo AVR4 Series Vaporizing Regulator may be configured in one of two
voltages, four heater wattages and two temperature ranges:
The AVR4 Series Vaporizing Regulator Model Configurations are configured from the
ordering information in the Sales Literature as shown below.
Page 11
1. Installation and Operation Instructions for
AVR3 Series Steam Heated Vaporizing Regulator
AVR4 Series Electrically Heated Vaporizing Regulator
Page 12