0% found this document useful (0 votes)
61 views

AVR3AVR4IO

1. The document provides installation and operation instructions for Parker Hannifin AVR3 series steam heated and AVR4 series electrically heated vaporizing regulators. 2. Safety precautions are outlined, including only allowing trained personnel to install and operate the devices. Operating conditions specify the regulators can operate continuously from -20C to 40C and have a maximum sample gas input of 3500 psig. 3. The installation instructions describe connecting inlet, outlet, and auxiliary connections and provide cautions on pressure ratings. For AVR4 models, installing heater power connections and adjusting the temperature setting are covered.

Uploaded by

k O
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
61 views

AVR3AVR4IO

1. The document provides installation and operation instructions for Parker Hannifin AVR3 series steam heated and AVR4 series electrically heated vaporizing regulators. 2. Safety precautions are outlined, including only allowing trained personnel to install and operate the devices. Operating conditions specify the regulators can operate continuously from -20C to 40C and have a maximum sample gas input of 3500 psig. 3. The installation instructions describe connecting inlet, outlet, and auxiliary connections and provide cautions on pressure ratings. For AVR4 models, installing heater power connections and adjusting the temperature setting are covered.

Uploaded by

k O
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

INSTALLATION and OPERATION

INSTRUCTIONS FOR

AVR3 Series
Steam Heated Vaporizing Regulator

AVR4 Series
Electrically Heated Vaporizing Regulator

AVR4 Series
Certifications

KEMA 03ATEX2359

Parker Hannifin, Veriflo Division


2801 Arrowhead Drive
Carson City, Nevada 89706
USA

1. Approved for use in explosive atmospheres.


2. ATEX Related Drawing: Changes must be made in accordance with 54099313.
3. Ref: ATEX Schedule Drawing 54013150
4. Ref: CSA File # LR 99181

E.O. 29782 17000812 Rev. C 8/03

Page 1
1. Installation and Operation Instructions for
AVR3 Series Steam Heated Vaporizing Regulator
AVR4 Series Electrically Heated Vaporizing Regulator

Contents
I. Statement of Liability
II. Safety
III. Operating Conditions
IV. Installation - Figure 1
V. Maintenance
VI. Regulator Operation
VII. Voltage and Power Rating Configurations
VIII. Product Marking

I. Statement of Liability

WARNING - FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS


AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL
INJURY AND PROPERTY DAMAGE.

This document and other information from Veriflo Division of Parker


Hannifin Corporation, its representatives and authorized distributors
provide product and/or system options for further investigation by users
having technical expertise. It is important that the user analyze all
aspects of its application and review the information concerning the
product in the current product catalog. Due to the variety of operating
conditions and applications for this product, you, the customer, through
your own analysis and testing, are solely responsible for making the final
selection of the products and systems and assuring that all performance,
safety and warning requirements of the application are met.

II. Safety

Observe all safety rules when connecting or operating this device with any
electrical and/or pressure system.

This device is to be installed and operated by trained personnel only.

The user should not assume that all safety measures are indicated in this
manual, or that other such measures may not be required.

Servicing and repairs to this equipment should be made by Veriflo/Parker


authorized personnel only. Use Veriflo/Parker replacement parts only.

III. Operating Conditions

The product requires no specific orientation but should be securely


mounted for safe operation. Both Junction Box mounting holes and Regulator
panel mount are provided.

The AVR4 is designed to operate continuously at ambient temperatures from


–20C to 40C.

Electrical input is designed for 120VAC or 240VAC, 50/60 Hz.


Power: 40, 100, 150 and 200 Watts
Maximum sample gas input is 3500 psig (24 MPa).

E.O. 29782 17000812 Rev. C 8/03

Page 2
1. Installation and Operation Instructions for
AVR3 Series Steam Heated Vaporizing Regulator
AVR4 Series Electrically Heated Vaporizing Regulator

IV. Installation - Figure 1

1. Mount regulator and heater assembly securely.

2. Install inlet (HP), outlet (LP) and, if applicable, auxiliary (AUX LP)
connections:

CAUTION - AVR3 and AVR4 regulators are marked with maximum rated inlet
pressure and regulated pressure range. Accessories such as gauges, relief
valves or special fittings may be assembled to the regulator and may have
lower rated pressures. Always observe the lowest pressure rating when
connecting accessories to the regulator or connecting the regulator to any
pressure source.

Use Teflon (TFE) tape or sealant for pipe threaded connections if


appropriate for the application.

Parker low volume internal compression fittings do not require lubrication


or sealant.

Test all connections for leakage.

3. AVR4 ONLY - Install heater power connections - Figure 2:

RECOMMENDATIONS - Conductors should be 18 awg minimum. Use #6 spade or


ring lugs for AC wiring. Use #8 ring lug for ground connections.
Insulation should be rated in excess of junction box internal temperature.
Shield ground should be connected to junction box housing or ground.
Flexible cabling or wiring should be strain relief clamped at junction box
housing entry.

For installations in the European Union (EU)

The cable entry device shall be certified in type of explosion protection


flameproof enclosure “d”, suitable for the conditions of use and correctly
installed.

For external earthing or bonding a cable lug shall be used so that the
conductor is secured against loosening and twisting and that contact
pressure is permanently secured.

CAUTION - Observe all legal, regulatory and industrial requirements for AC


wiring.

Connect external ground (#8 green screw) if required.

Loosen junction box cover setscrew (1/16" internal hex) and remove cover.

Connect AC Supply ground to #8 green ground screw.

Connect AC Supply to #6 "AC IN" terminals -


connections have no polarity assigned

Verify AC Supply voltage and recheck connections before applying power.

E.O. 29782 17000812 Rev. C 8/03

Page 3
1. Installation and Operation Instructions for
AVR3 Series Steam Heated Vaporizing Regulator
AVR4 Series Electrically Heated Vaporizing Regulator

4. AVR4 ONLY - Verify heater operation - Figure 2:

Connect 0-250 VAC analog or non-auto ranging voltmeter across heater leads
(brown wires).

Turn temperature control to mid-range.

Apply AC power.

Voltage should drop when set point is reached and then cycle.

Adjust temperature control to approximate setting desired - temperature


scale is reference only and must be set with application in process - see
5. below

Replace junction box cover and tighten cover setscrew.

5. AVR4 ONLY - Adjust Temperature - Figure 2:

The approximate temperature set during installation does not account for
the mass flow or thermodynamic properties of the media or for
environmental conditions. The process temperature must be established
with the AVR4 installed and operating at desired inlet and outlet
pressures and with the media flowing at the desired rate.

Loosen junction box cover setscrew (1/16" internal hex) and remove cover.
Establish process media flow conditions.

Set temperature control to setting desired -


Temperature scale is reference only.
Turn adjustment CW to raise temperature.
Turn adjustment CCW to lower temperature.

Reinstall junction box cover and lock with setscrew.

6. AVR3 ONLY - Install steam heater connections:

Heater connections have no assigned flow direction.

Use Teflon (TFE) tape or sealant for pipe threaded connections if


appropriate for the application.

Test connections for leakage.

E.O. 29782 17000812 Rev. C 8/03

Page 4
1. Installation and Operation Instructions for
AVR3 Series Steam Heated Vaporizing Regulator
AVR4 Series Electrically Heated Vaporizing Regulator

7. AVR3 ONLY - Temperature Adjustment:

The process media temperature is effected by the mass flow and


thermodynamic properties of the media and by environmental conditions.
The process temperature must be established with the AVR3 installed and
operating at desired inlet and outlet pressures and with the media flowing
at the desired rate.

The media temperature of the AVR3 is controlled by the energy flow of the
steam supplied. The controllable variables are flow, temperature and
pressure.

8. Adjust regulator outlet pressure (LP) - Figure 1:

The regulator is set at 0 psig and no flow at the factory. The process
outlet pressure should be set under actual inlet pressure and media flow
conditions.

Apply process inlet pressure (HP).

Remove tamperproof nut (1/2" hex).

Initiate flow -
Turn stem (1/8" internal hex) slowly clockwise (CW) to raise outlet
(LP) to desired pressure.

Establish process media flow conditions.

Adjust process outlet pressure (LP) -


Turn stem clockwise (CW) to raise outlet pressure.
Turn stem counter-clockwise (CCW) to lower outlet pressure.

Reinstall tamperproof nut to lock setting.

E.O. 29782 17000812 Rev. C 8/03

Page 5
1. Installation and Operation Instructions for
AVR3 Series Steam Heated Vaporizing Regulator
AVR4 Series Electrically Heated Vaporizing Regulator

V. Maintenance

CAUTION - Replace all damaged, worn and/or corroded parts.


Use Veriflo/Parker replacement parts only.

1. Cleaning Heater - Figure 3.

Note - the heater assembly or regulator must be dismounted and free to


separate approximately 2" (5 cm).

AVR3 ONLY - Shutoff steam supply and allow unit to cool to safe handling
temperature.

AVR4 ONLY - Shutoff electrical power and allow unit to cool to safe
handling temperature.

Shutoff inlet (HP) and outlet (LP) pressure.


Vent outlet so as not to exceed safe pressure limits -see Para V.2.,
Supply Pressure Effect

Disconnect media and/or heater connections as necessary.

Loosen and remove three (3) 3/8-16 bolts (9/16" hex) from heater collar.

Pull heater housing from the regulator body.

Use a suitable probe to remove screen from heater cavity in regulator


body.

Clean heat transfer threads with 5/8-24 UNF thread die and/or wire brush.

Clean or replace screen.

Replace housing seal and outer o-ring.

Install heater collar and tighten 3/8-16 bolts evenly -


torque to 18-22 in-lb (2.0-2.5 Nm)

Remount heater and regulator assembly securely.

Reinstall all connections.

Test all connections for leakage before returning the unit to service.

E.O. 29782 17000812 Rev. C 8/03

Page 6
1. Installation and Operation Instructions for
AVR3 Series Steam Heated Vaporizing Regulator
AVR4 Series Electrically Heated Vaporizing Regulator

2. AVR4 ONLY - Heater/Controller Replacement - Figure 2.

Note - Heaters and controllers have a finite life and do require


replacement. If, however, an extraordinary failure is suspected,
determine and repair the cause of failure before replacing the heater and
controller.

Shutoff electrical power and allow unit to cool to safe handling


temperature.

Loosen junction box cover setscrew (1/16" internal hex) and remove cover.

Disconnect AC Supply and ground connections.

Loosen terminal block connections - two (2) 6-32 x 3/16" slotted head
screws and two (2) 6-32 x 1/4 male/female standoffs (1/4" hex).

Remove controller.

Disconnect heater leads and slip heater out of housing.

Before installing replacement units, verify that power rating and supply
voltage are correct.

Slip replacement heater into housing, install controller and reconnect


heater leads as shown in Figure 2. Carefully route wiring clear of
junction box cover threads.

Connect AC Supply ground to green ground screw.

Connect AC Supply to "AC IN" terminals -


connections have no polarity assigned

Verify AC Supply voltage and recheck connections.

Verify heater operation per Para III.4. above.

Replace junction box cover and tighten cover setscrew.

3. All other service operations must be carried out by Veriflo/Parker


authorized repair personnel.

E.O. 29782 17000812 Rev. C 8/03

Page 7
1. Installation and Operation Instructions for
AVR3 Series Steam Heated Vaporizing Regulator
AVR4 Series Electrically Heated Vaporizing Regulator

VI. Regulator Operation

1. Regulator Outlet Settings -

The outlet pressure of a regulator is a function of the mechanical


setting, the inlet supply pressure and the flow rate. A decrease in inlet
pressure will cause an increase the regulator's outlet pressure - see Para
V.2., Supply Pressure Effect. An increase in flow rate will cause a drop
in outlet pressure - see Para V.3., Flow Curves. The AVR3 and AVR4
regulators are set at the factory to 0 psig. The outlet pressure must be
adjusted under installed conditions.

2. Supply Pressure Effect -

A regulator's outlet pressure is effected inversely by changes in it's


inlet pressure. The supply pressure effect for the AVR series regulators
is approximately 0.5 psig (3.5 kPa) increase in outlet pressure for every
100 psig (690 kPa) decrease in inlet pressure.

The effect can be hazardous when shutting down the inlet supply. Care
must be taken to maintain flow or vent the outlet when decreasing the
inlet pressure to protect against increases in outlet pressure.

3. Flow Curves -

Under conditions of constant ambient conditions and inlet pressure the


decrease in outlet pressure as a function of increasing flow rate is a
repeatable regulator characteristic. The graphical representation of this
relationship is a flow curve. Although a flow curve is plotted for a
given set of conditions, it can be interpreted to describe performance
under other conditions. Typical flow curves are presented in the product
brochures:

Catalog 4512 AVR3 Series Steam Heated Vaporizing Regulator


Catalog 4512 AVR4 Series Electrically Heated Vaporizing Regulator
See Parker Hannifin, Veriflo Website www.parker.com/veriflodivision

4. Lockup (Creep) -

The lockup pressure is the rise in outlet pressure which occurs when flow
is reduced to zero while maintaining inlet pressure. This reflects the
force required to seal off the regulator. The lockup pressure for an AVR3
or AVR4 regulator with PCTFE seat is under 2 psi (13.8 kPa) with 1500 psig
(10.3 kPa) inlet. Other seat materials may result in higher lockup
pressures.

The lockup pressure of a regulator is a measure of the condition of the


regulator seat. As the seat becomes contaminated or otherwise degraded,
lockup pressure increases. As failure progresses, the regulator outlet
pressure can rise to dangerous levels at supposed shutoff. For this
reason it is advised that a regulator always be used in conjunction with
an inlet shutoff valve. Always service regulators when abnormal lockup
pressure is noted.

E.O. 29782 17000812 Rev. C 8/03

Page 8
1. Installation and Operation Instructions for
AVR3 Series Steam Heated Vaporizing Regulator
AVR4 Series Electrically Heated Vaporizing Regulator

AVR3 OUTLINE DRAWING

AVR4 OUTLINE DRAWING


FIGURE 1

E.O. 29782 17000812 Rev. C 8/03

Page 9
1. Installation and Operation Instructions for
AVR3 Series Steam Heated Vaporizing Regulator
AVR4 Series Electrically Heated Vaporizing Regulator

AVR4 JUNCTION BOX


FIGURE 2

AVR3 & AVR4 EXPLODED VIEW


FIGURE 3

E.O. 29782 17000812 Rev. C 8/03

Page 10
1. Installation and Operation Instructions for
AVR3 Series Steam Heated Vaporizing Regulator
AVR4 Series Electrically Heated Vaporizing Regulator

VII. Voltage and Power Rating Configurations – AVR4 Only

The heater ratings used in the product series are:

40 Watt, 120 VAC, 50-60 Hz


40 Watt, 240 VAC, 50-60 Hz
100 Watt, 120 VAC, 50-60 Hz
100 Watt, 240 VAC, 50-60 Hz
150 Watt, 120 VAC, 50-60 Hz
150 Watt, 240 VAC, 50-60 Hz
200 Watt, 120 VAC, 50-60 Hz
200 Watt, 240 VAC, 50-60 Hz

The temperature controller units are designed to accommodate low (75F - 220F) and
high (215F - 380F) range applications. The unit is a completely encapsulated
component with a temperature adjustment control.

The Veriflo AVR4 Series Vaporizing Regulator may be configured in one of two
voltages, four heater wattages and two temperature ranges:

The AVR4 Series Vaporizing Regulator Model Configurations are configured from the
ordering information in the Sales Literature as shown below.

E.O. 29782 17000812 Rev. C 8/03

Page 11
1. Installation and Operation Instructions for
AVR3 Series Steam Heated Vaporizing Regulator
AVR4 Series Electrically Heated Vaporizing Regulator

VIII. Product Marking

AVR3 & AVR4 Marking:

Additional Marking - AVR4 Only Additional Marking – AVR3 Only

E.O. 29782 17000812 Rev. C 8/03

Page 12