0% found this document useful (0 votes)
21 views

ZLand Spec Sheets Aug2016

ZLand is a seismic data recorder with the following key specifications: It can record 1 seismic data channel with up to 24-bit ADC resolution and sample intervals of 0.5, 1, 2, or 4 milliseconds. It has preamplifier gains between 0 and 36 dB, operates between -40°C and 60°C, and can store up to 2GB of data. Key performance metrics include less than 0.0003% total harmonic distortion, input noise below 1 microvolt, over 127dB of dynamic range, and better than 90dB of common mode rejection ratio. The unit is powered by a rechargeable lithium-ion battery, has a weight of 4.8 pounds

Uploaded by

kankukejardikau1
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
21 views

ZLand Spec Sheets Aug2016

ZLand is a seismic data recorder with the following key specifications: It can record 1 seismic data channel with up to 24-bit ADC resolution and sample intervals of 0.5, 1, 2, or 4 milliseconds. It has preamplifier gains between 0 and 36 dB, operates between -40°C and 60°C, and can store up to 2GB of data. Key performance metrics include less than 0.0003% total harmonic distortion, input noise below 1 microvolt, over 127dB of dynamic range, and better than 90dB of common mode rejection ratio. The unit is powered by a rechargeable lithium-ion battery, has a weight of 4.8 pounds

Uploaded by

kankukejardikau1
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

ZLand Technical Summar y

Chapter 2 – ZLand Technical Summary


2
Tech

ZLand NODE Typical


Performance Sheet
Seismic Data Channels 1
ADC Resolution 24 bits
Sample Interval 0.5, 1, 2, 4 milliseconds
Preamplifier Gain 0 dB to 36 dB in 6 dB steps
Anti-Alias Filter 206.5 Hz @ 2ms (82.6% of Nyquist), Linear Phase
DC Blocking Filter 1 Hz to 60 Hz, 1 Hz increments, 6 dB/Octave, or OUT
Operating Temperature Range -40˚C to +60˚C
Operating Life 15 days/ 360 hours Continuous
25 days Segmented (12 hours ON/12 hours SLEEP)
Data Storage 2GB NAND Flash Memory
Seismic Data Channels 1
Acquisition Channel @ 2ms sample interval, 25°C, 31.25Hz, internal test, unless otherwise indicated
Total Harmonic Distortion 0.0003% @ 12 dB gain, -3dB Full Scale
Equivalent Input Noise 0.75µVrms @ 0dB
0.2µVrms @ 12dB
0.1µVrms @ 24dB
0.1µVrms @ 36dB

Full Scale Input Signal 2500mV peak @ 0 dB


625mV peak @ 12 dB
156mV peak @ 24 dB
39mV peak @ 36 db

Gain Accuracy 1%
Dynamic Range 127dB @ 0 dB Preamplifier Gain
Common Mode Rejection Ratio >90 dB
DC Offset <10% of Input Noise with DC Blocking Filter IN
Timing Accuracy ±10 seconds UTC, GPS Disciplined
Self Test Features
Internal Noise (preamp input terminated)
Internal THD
Internal Gain Accuracy
Internal CMRR
Internal Impulse
Sensor Impedance
Sensor Geophone, Single, Vertical, 10 Hz,
70% damped, 2 V/i/s (78.7 V/m/s)
Battery
Type Rechargeable Li-Ion
Charging Temperature Range +3˚C to +40˚C
Recharge Time < 5 hours
Physical
Weight 4.8 lb (2.17 kg), excluding spike
Dimensions 5 in (12.7 cm) diameter by 6 in (15.2 cm) high
Detachable Spike 5 in (12.7 cm) long, detachable
0.35 lb (0.16 kg) including bolt & washer

All specifications relate to Node Part Number 221.6906.0007 only.


FairfieldNodal reserves the right to change specifications without notice to provide the best possible product.
May 13, 2016 ZLAND Users Manual