SUN2000L-(2KTL-5KTL)

User Manual

Issue 05

Date 2019-06-06

HUAWEI TECHNOLOGIES CO., LTD.


Copyright © Huawei Technologies Co., Ltd. 2019. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior
written consent of Huawei Technologies Co., Ltd.

Trademarks and Permissions

and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.

Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees or
representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.

Huawei Technologies Co., Ltd.


Address: Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China
Website: http://e.huawei.com

Issue 05 (2019-06-06) i
Copyright © Huawei Technologies Co., Ltd.
SUN2000L-(2KTL-5KTL)
User Manual About This Document

About This Document

Purpose
This document describes the SUN2000L-(2KTL-5KTL) in terms of its installation, electrical
connections, commissioning, maintenance, and troubleshooting. SUN2000L-(2KTL-5KTL) is
abbreviated as SUN2000L. Before installing and operating the SUN2000L, ensure that you
are familiar with the features, functions, and safety precautions provided in this document.

Intended Audience
This document is intended for:
 Installers
 Users

Symbol Conventions
The symbols that may be found in this document are defined as follows.

Symbol Description

Indicates an imminently hazardous situation which, if not


avoided, will result in serious injury or death.

Indicates a potentially hazardous situation which, if not


avoided, could result in serious injury or death.

Indicates a potentially hazardous situation which, if not


avoided, may result in minor or moderate injury.

Indicates a potentially hazardous situation which, if not


avoided, could result in equipment damage, data loss,
performance deterioration, or unanticipated results.
NOTICE is used to address practices not related to
personal injury.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. ii


SUN2000L-(2KTL-5KTL)
User Manual About This Document

Symbol Description

Calls attention to important information, best practices


and tips.
NOTE is used to address information not related to
personal injury, equipment damage, or environment
deterioration.

Change History
Changes between document issues are cumulative. The latest document issue contains all
updates made in previous issues.

Issue 05 (2019-06-06)
 Delete the CHINT-DDSU666 Smart Power Sensor in 5.1 Preparing Cables.
 The FusionHome app is updated to the FusionSolar app.
 Updated the Nameplate.

Issue 04 (2018-12-26)
Added the following description in 5.1 Preparing Cables: the CHINT-DDSU666 Smart Power
Sensor supports two communication protocols: Modbus and DLT645. Purchase a
CHINT-DDSU666 Smart Power Sensor using the Modbus protocol. The CHINT-DDSU666
Smart Power Sensor that uses the DLT645 communication protocol is unavailable.

Issue 03 (2018-03-28)
Upgraded the FusionHome app to 2.1.11.217.

Issue 02 (2017-12-12)
Upgraded the FusionHome app to 2.1.11.201.

Issue 01 (2017-09-27)
This issue is used for first office application (FOA).

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. iii


SUN2000L-(2KTL-5KTL)
User Manual Contents

Contents

About This Document .................................................................................................................... ii


1 Safety Precautions ......................................................................................................................... 1
2 Product Overview ......................................................................................................................... 5
2.1 Product Introduction ..................................................................................................................................................... 5
2.2 Appearance ................................................................................................................................................................... 7
2.3 Label Descriptions ...................................................................................................................................................... 11
2.4 Working Principles ..................................................................................................................................................... 14

3 Storage ........................................................................................................................................... 17
4 System Installation ..................................................................................................................... 18
4.1 Checking Before Installation ...................................................................................................................................... 18
4.2 Tools and Instruments ................................................................................................................................................. 19
4.3 Determining the Installation Position ......................................................................................................................... 20
4.4 Installing the Mounting Bracket ................................................................................................................................. 24
4.4.1 Wall-Mounted Installation ....................................................................................................................................... 25
4.4.2 Support-mounted Installation .................................................................................................................................. 27
4.5 Installing the SUN2000L ............................................................................................................................................ 29
4.6 Installing the WiFi Antenna ........................................................................................................................................ 33

5 Electrical Connections ................................................................................................................ 34


5.1 Preparing Cables ......................................................................................................................................................... 35
5.2 Installing the PE Cable ............................................................................................................................................... 38
5.3 Installing the AC Output Power Cable........................................................................................................................ 40
5.4 Installing the DC Input Power Cable .......................................................................................................................... 44
5.5 Installing Battery Cables............................................................................................................................................. 50
5.6 Installing the Signal Cable .......................................................................................................................................... 52

6 System Commissioning ............................................................................................................. 58


6.1 Checking Before Power-On ........................................................................................................................................ 58
6.2 Powering On the System............................................................................................................................................. 59
6.3 Commissioning ........................................................................................................................................................... 61
6.3.1 Scenario 1: Commissioning Through Setup Wizard ................................................................................................ 61
6.3.2 Scenario 2: Device Commissioning ......................................................................................................................... 63

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. iv


SUN2000L-(2KTL-5KTL)
User Manual Contents

6.4 Energy Control............................................................................................................................................................ 66


6.4.1 Grid-tied Point Control ............................................................................................................................................ 66
6.4.2 Energy Storage Control............................................................................................................................................ 67
6.5 IPS Test (for Italy CEI0-21 Grid Code only) .............................................................................................................. 70
6.6 Powering Off the System ............................................................................................................................................ 72

7 System Maintenance .................................................................................................................. 74


7.1 Routine Maintenance .................................................................................................................................................. 74
7.2 Troubleshooting .......................................................................................................................................................... 75

8 Handling the SUN2000L ............................................................................................................ 82


8.1 Removing the SUN2000L .......................................................................................................................................... 82
8.2 Packing the SUN2000L .............................................................................................................................................. 82
8.3 Disposing of the SUN2000L....................................................................................................................................... 82

9 Technical Specifications ............................................................................................................ 83


A Grid Codes................................................................................................................................... 87
B Acronyms and Abbreviations .................................................................................................. 92

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. v


SUN2000L-(2KTL-5KTL)
User Manual 1 Safety Precautions

1 Safety Precautions

General Safety

 Before performing operations, read through this manual and follow all the precautions to
prevent accidents. The "DANGER," "WARNING," "CAUTION," and "NOTICE"
statements in this document do not represent all the safety instructions. They are only
supplements to the safety instructions.
 Only certified electricians are allowed to install, connect cables for, commission, maintain,
and troubleshoot Huawei products, and they must understand basic safety precautions to
avoid hazards.

When operating Huawei equipment, in addition to following the general precautions in this
document, follow the specific safety instructions given by Huawei. Huawei will not be liable
for any consequence caused by the violation of the safety operation regulations and design,
production, and usage standards.

Disclaimer
Huawei shall not be liable for any consequence caused by any of the following events:
 Damage caused by transportation
 Storage conditions that do not meet the requirements specified in this document
 Incorrect storage, installation, or use
 Installation or use by unqualified personnel
 Failure to comply with the operation instructions and safety precautions in this document
 Operation in extreme environments which are not covered in this document
 Operation beyond specified ranges
 Unauthorized modifications to the product or software code or removal of the product
 Device damage due to force majeure (such as lightning, earthquakes, fire, and storms)
 Warranty expiration without extension of the warranty service
 Installation or use in environments which are not specified in related international
standards

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 1


SUN2000L-(2KTL-5KTL)
User Manual 1 Safety Precautions

Personnel Requirements
Only certified electricians are allowed to install, connect cables for, commission, maintain,
troubleshoot, and replace the SUN2000L. They should:
 Receive professional training.
 Read through this document and follow all the precautions.
 Be familiar with the safety specifications about the electrical system.
 Understand the composition and working principles of the grid-tied PV system and local
regulations.
 Wear proper personal protective equipment (PPE).

Protecting Labels
 Do not scrawl or damage any labels on the SUN2000L enclosure because these labels
contain important information about safe operation.
 Do not scrawl or damage the nameplate on the SUN2000L enclosure. This nameplate
contains important product information.

Installation

Never power on the SUN2000L during installation.


 Ensure that the SUN2000L is not connected to a power supply or powered on before
installation is complete.
 To allow proper heat dissipation and installation, maintain appropriate clearances
between the SUN2000L and other objects, as shown in Figure 1-1. If you have any
questions about the clearances, consult technical support engineers.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 2


SUN2000L-(2KTL-5KTL)
User Manual 1 Safety Precautions

Figure 1-1 Installation clearances

 Ensure that the SUN2000L is installed in a well-ventilated environment.


 Ensure that the SUN2000L heat sinks are free from blockage.
 Do not open the front panel of the SUN2000L.
 Do not remove the terminals and ports at the bottom of the SUN2000L.

Electrical Connections

Before connecting cables, ensure that the SUN2000L is secured in position and not damaged
in any way. Otherwise, electric shocks or fire may occur.
 Ensure that all electrical connections comply with the local electrical standards.
 Obtain approval from the local utility company before using the SUN2000L to generate
electricity in grid-tied mode.
 Ensure that the cables used in a grid-tied PV system are properly connected and insulated
and meet all specification requirements.

Operation

The high voltage generated by the SUN2000L during operation may cause an electric shock,
which can result in serious property damage, serious injury, or death. Strictly comply with the
safety precautions in this document and associated documents when operating the
SUN2000L.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 3


SUN2000L-(2KTL-5KTL)
User Manual 1 Safety Precautions

 When the SUN2000L is powered on for the first time, only certified electricians are
allowed to perform quick setting. Incorrect settings may affect the normal SUN2000L
operation and cause the SUN2000L to not comply with the country certification.
 When the SUN2000L is operating, do not disconnect under load.
 Do not touch an energized SUN2000L because the heat sink reaches a high temperature.
 Follow local laws and regulations when operating the equipment.

Maintenance and Replacement

The high voltage generated by the SUN2000L during operation may cause an electric shock,
which can result in serious property damage, serious injury, or death. Prior to maintenance,
power off the SUN2000L and strictly comply with the safety precautions in this document and
associated documents to operate the SUN2000L.
 Before performing maintenance on the SUN2000L, ensure that you have sufficient
knowledge of this document, and proper tools and testing equipment.
 Before performing maintenance tasks, power off the SUN2000L and wait at least 5
minutes.
 Temporary warning signs or fences must be placed to prevent unauthorized people from
entering the site.
 If the SUN2000L is faulty, contact your supplier.
 The SUN2000L can be powered on only after all faults are rectified. Failing to do so may
escalate faults or damage the device.
 Observe ESD precautions and wear ESD gloves during maintenance.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 4


SUN2000L-(2KTL-5KTL)
User Manual 2 Product Overview

2 Product Overview

2.1 Product Introduction


Function
The SUN2000L is a single-phase grid-tied PV string inverter that converts the DC power
generated by PV strings into AC power and feeds the electricity into the power grid.

Models
This document involves the following product models:
 SUN2000L-2KTL
 SUN2000L-3KTL
 SUN2000L-3.68KTL
 SUN2000L-4KTL
 SUN2000L-4.6KTL
 SUN2000L-5KTL

Figure 2-1 Designation explanation of the SUN2000L-5KTL

Table 2-1 Designation explanation of the SUN2000L-5KTL


No. Meaning Description

1 Series name SUN2000L: single-phase grid-tied PV string


inverter

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 5


SUN2000L-(2KTL-5KTL)
User Manual 2 Product Overview

No. Meaning Description

2 Power level  2K: The power level is 2K.


 3K: The power level is 3K.
 3.68K: The power level is 3.68K.
 4K: The power level is 4K.
 4.6K: The power level is 4.6K.
 5K: The power level is 5K.
3 Topology TL: transformerless

Networking Application
The SUN2000L applies to a residential rooftop grid-tied system. Typically, a grid-tied system
consists of the PV string, grid-tied inverter, AC switch, and power distribution unit.

Figure 2-2 Network diagram (dashed boxes indicate optional components)

indicates a power cable, indicates the power flow direction, and indicates a signal
cable.

(A) PV string (B) DC switch (C) SUN2000L


(D) AC switch (E) Power distribution unit (F) Smart Power Sensor
(G) Power meter (H) Power grid (I) Battery
(J) Battery switch (K) Alarm beacon (L) Residential load

Supported Power Grid


The power grids supported by the SUN2000L include TN-S, TN-C, TN-C-S, and TT. In a TT
power grid, the N-PE voltage should be lower than 30 V.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 6


SUN2000L-(2KTL-5KTL)
User Manual 2 Product Overview

Figure 2-3 Power grid types

2.2 Appearance
Front View

Figure 2-4 Front view

(1) LED 1 (2) LED 2 (3) LED 3 (4) Front panel

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 7


SUN2000L-(2KTL-5KTL)
User Manual 2 Product Overview

Table 2-2 LED description

Type Status Meaning

Running LED 1 LED 2 N/A


indication
Steady green Steady green The SUN2000L is exporting
power to the power grid.
Blinking green at Off The DC is on and the AC is
long intervals (on off.
for 1s and then
off for 1s)
Off Blinking green at The DC is off and the AC is
long intervals (on on.
for 1s and then
off for 1s)
Blinking green at Blinking green at The DC is on, the AC is on,
long intervals (on long intervals (on and the SUN2000L is not
for 1s and then for 1s and then exporting power to the power
off for 1s) off for 1s) grid.
Off Off Both the DC and AC are off,
or the SUN2000L is in Low
Power Consumption mode.
Low Power Consumption
mode means that the
monitoring system of the
SUN2000L is hibernating.
Steady red Steady red The SUN2000L is faulty.

Communication LED 3 N/A


indication
Blinking green at short intervals (on Communicating
for 0.2s and then off for 0.2s) (Communicating means that
the communication with the
upper-level management unit
is in progress. However, if a
mobile phone accesses the
SUN2000L, the LED
indicates the "mobile phone
access status: blinking green
at long intervals" first.)
Blinking green at long intervals (on The mobile phone is
for 1s and then off for 1s) connected to the SUN2000L.
Off No communication

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 8


SUN2000L-(2KTL-5KTL)
User Manual 2 Product Overview

Rear View

Figure 2-5 Rear view

(1) Mounting plate (2) Mounting bracket (3) Heat sink

Bottom View

Figure 2-6 Bottom view

No. Component Silk Screen

1 DC switch DC SWITCH
2 DC input terminal PV+/PV–
3 Battery terminal BAT+/BAT–

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 9


SUN2000L-(2KTL-5KTL)
User Manual 2 Product Overview

No. Component Silk Screen

4 COM port COM


5 AC output port AC
6 Ventilation valve N/A
7 Antenna port ANT
8 Alarm port ALARM
9 Ground point N/A

Dimensions

Figure 2-7 Enclosure dimensions

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 10


SUN2000L-(2KTL-5KTL)
User Manual 2 Product Overview

Figure 2-8 Mounting bracket dimensions

2.3 Label Descriptions


Labels

Table 2-3 Label description

Symbol Name Meaning

Burn warning Do not touch a running


SUN2000L because the
shell is hot when the
SUN2000L is running.
Delay discharge  High voltage exists
after the SUN2000L is
powered on. Only
qualified and trained
electrical technicians
are allowed to perform
operations on the
SUN2000L.
 Residual voltage exists
after the SUN2000L is
powered off. It takes 5
minutes for the
SUN2000L to
discharge to the safe
voltage.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 11


SUN2000L-(2KTL-5KTL)
User Manual 2 Product Overview

Symbol Name Meaning

Refer to documentation Reminds operators to


refer to the documents
supplied with the
SUN2000L.
Grounding Indicates the position for
connecting the protective
earthing (PE) cable.

Operation warning Do not remove the


connector or antenna
when the SUN2000L is
running.
Indicator status Describes the indicator
description label status.

SUN2000L serial number Indicates the SUN2000L


(SN) label SN.

SUN2000L MAC address Indicates the MAC


label address.

QR code for SUN2000L Scan the QR code to


WiFi connection connect to Huawei
SUN2000L WiFi network
(Android) or obtain the
WiFi password (iOS).

The labels are for reference only.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 12


SUN2000L-(2KTL-5KTL)
User Manual 2 Product Overview

Nameplate

Figure 2-9 Nameplate

(1) Trademark and product model (2) Important technical specifications


(3) Compliance symbols (4) Company name and country of manufacture

The nameplate figure is for reference only.

Table 2-4 Compliance symbols

Symbol Name Meaning

RCM certification mark The SUN2000L complies


with RCM certification
standards.
CE certification mark The SUN2000L complies
with Conformité
Européenne (CE)
certification standards.
TÜVRheinland The SUN2000L complies
certification mark with TÜVRheinland
certification standards.
Environment friendly use The product does not
period (EFUP) mark pollute the environment
during the specified
period.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 13


SUN2000L-(2KTL-5KTL)
User Manual 2 Product Overview

Symbol Name Meaning

EU waste electrical and Do not dispose of the


electronic equipment product as household
(WEEE) mark garbage.

2.4 Working Principles


Conceptual Diagram
The SUN2000L receives two in puts from the two PV strings. Two MPPT circuits are
configured inside the SUN2000L. Each circuit tracks the maximum power point of one PV
string respectively. The DC power is then converted into single-phase AC power through an
inverter circuit. Surge protection is supported on both the DC and AC sides.
The SUN2000L has a reserved battery port to connect to batteries, which are used to store the
surplus power produced by PV strings and not required by residential loads. The power stored
in batteries can be exported to the power grid based on the load condition to meet peak and
valley power consumption requirements and maximize the benefits.

Figure 2-10 Conceptual diagram

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 14


SUN2000L-(2KTL-5KTL)
User Manual 2 Product Overview

Working Modes

Figure 2-11 Working modes

Table 2-5 Working mode description


Working Description
Mode

Standby The SUN2000L enters Standby mode when the external environment does
not meet the requirements for starting the SUN2000L. In Standby mode:
 The SUN2000L continuously checks its status and enters Operating
mode once the operating requirements are met.
 The SUN2000L enters Shutdown mode after detecting a shutdown
command or a fault after startup.
Operating In Operating mode:
 The SUN2000L converts DC power from PV strings into AC power and
feeds the energy to the power grid.
 The SUN2000L tracks the maximum power point to maximize the PV
string output.
 The SUN2000L enters Shutdown mode after detecting a fault or a
shutdown command, and enters Standby mode after detecting that the
PV string output power is not suitable for connecting to the power grid
and producing power.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 15


SUN2000L-(2KTL-5KTL)
User Manual 2 Product Overview

Working Description
Mode

Shutdown  In Standby or Operating mode, the SUN2000L enters Shutdown mode


after detecting a fault or shutdown command.
 In Shutdown mode, the SUN2000L enters Standby mode after detecting
a startup command or that the fault is rectified.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 16


SUN2000L-(2KTL-5KTL)
User Manual 3 Storage

3 Storage

The following requirements should be met when the SUN2000L needs to be stored prior to
installation:
 Do not unpack the SUN2000L.
 Keep the storage temperature at –40°C to +70°C and the humidity at 5%–95% RH.
 The SUN2000L should be stored in a clean and dry place and be protected from dust and
water vapor corrosion.
 A maximum of 10 SUN2000Ls can be stacked. To avoid personal injury or device
damage, stack SUN2000Ls with caution to prevent them from falling over.
 Regular inspection is required during the storage. Replace the packing materials when
necessary.
 After long-term storage, the SUN2000L needs to be inspected and tested by qualified
persons before it is put into use.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 17


SUN2000L-(2KTL-5KTL)
User Manual 4 System Installation

4 System Installation

4.1 Checking Before Installation


Outer Packing Materials
Before unpacking the SUN2000L, check the outer packing materials for damage, such as
holes and cracks, and check the SUN2000L model. If any damage is found or the SUN2000L
model is not what you requested, do not unpack the product and contact your supplier as soon
as possible.

You are advised to remove the packing materials no more than 24 hours before installing the
SUN2000L.

Package Contents
After unpacking the SUN2000L, check that the contents are intact and complete. If any
damage is found or any component is missing, contact your supplier.

For details about the number of contents, see the Packing List in the packing case.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 18


SUN2000L-(2KTL-5KTL)
User Manual 4 System Installation

4.2 Tools and Instruments


Category Tools and Instruments

Hammer drill (with a Ф10 Torque socket wrench (open Torque wrench (open end: 13
mm drill bit) end: 13 mm, applicable for mm; torque range: 0–1.5
M8 bolts; torque range: 0–15 N•m)
N•m)

Diagonal pliers Wire stripper Torque screwdriver (head:


M4 or M6; torque range: 0–5
N•m)

Installation

Rubber mallet Utility knife Cable cutter

Crimping tool (model: Open-end wrench (model: Cable tie


UTXTC0005/H4TC0003; H4TW0001; manufacturer:
manufacturer: Amphenol) Amphenol)

Vacuum cleaner Multimeter (DC voltage Marker


measurement range ≥ 600 V
DC)

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 19


SUN2000L-(2KTL-5KTL)
User Manual 4 System Installation

Category Tools and Instruments

Measuring tape Bubble or digital level Hydraulic pliers


N/A

Heat shrink tubing Heat gun

Safety gloves Safety goggles Anti-dust respirator


PPE
N/A N/A

Safety shoes

4.3 Determining the Installation Position


Basic Requirements
 The SUN2000L is protected to IP65 and can be installed indoors or outdoors.
 Do not install the SUN2000L in a place where a person can easily touch it because its
enclosure and heat sinks are extremely hot during operation.
 Do not install the SUN2000L in areas with flammable or explosive materials.
 Do not install the SUN2000L at a place within children's reach.
 Do not install the SUN2000L outdoors in salt areas because it will be corroded there and
may cause fire. A salt area refers to the region within 500 meters from the coast or prone
to sea breeze. The regions prone to sea breeze vary depending on weather conditions
(such as typhoons and monsoons) or terrains (such as dams and hills).

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 20


SUN2000L-(2KTL-5KTL)
User Manual 4 System Installation

Installation Environment Requirements


 The SUN2000L must be installed in a well-ventilated environment to ensure good heat
dissipation.
 When installed under direct sunlight, the power of the SUN2000L may be derated due to
additional temperature rise.
 Install the SUN2000L in a sheltered place or install an awning over the SUN2000L.

Mounting Structure Requirements


 The mounting structure where the SUN2000L is installed must be fireproof.
 Do not install the SUN2000L on flammable building materials.
 Ensure that the installation surface is solid enough to bear the weight load.
 In residential areas, do not install the SUN2000L on drywalls or walls made of similar
materials which have a weak sound insulation performance because the noise generated
by the SUN2000L is noticeable.

Installation Angle Requirements


The SUN2000L can be wall-mounted or pole-mounted. The installation angle requirements
are as follows:
 Install the SUN2000L vertically or at a maximum back tilted angle of 15 degrees to
facilitate heat dissipation.
 Do not install the SUN2000L at forward tilted, excessively back tilted, side tilted,
horizontal, or upside down positions.

Figure 4-1 Installation angle

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 21


SUN2000L-(2KTL-5KTL)
User Manual 4 System Installation

Installation Clearance Requirements


 Reserve enough clearance around the SUN2000L to ensure sufficient space for
installation and heat dissipation.

Figure 4-2 Installation clearance requirements

 When installing multiple SUN2000Ls, install them in horizontal mode if the space is
sufficient and install them in staggered mode if the space is insufficient. Stacked
installation is not recommended.

Figure 4-3 Horizontal installation mode (recommended)

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 22


SUN2000L-(2KTL-5KTL)
User Manual 4 System Installation

Figure 4-4 Staggered installation mode (recommended)

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 23


SUN2000L-(2KTL-5KTL)
User Manual 4 System Installation

Figure 4-5 Stacked installation mode (not recommended)

4.4 Installing the Mounting Bracket


Fixing holes can be used in three combinations. Select a hole combination based on site
requirements. Combination A is preferred.

Figure 4-6 Hole combinations

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 24


SUN2000L-(2KTL-5KTL)
User Manual 4 System Installation

Figure 4-7 Hole distances

4.4.1 Wall-Mounted Installation


Procedure
Step 1 Determine the positions for drilling holes using the mounting bracket. Level the positions of
mounting holes using a bubble or digital level, and mark the positions with a marker.

Figure 4-8 Determining hole positions

Step 2 Install expansion bolts.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 25


SUN2000L-(2KTL-5KTL)
User Manual 4 System Installation

Avoid drilling holes in the utility pipes and/or cables attached to back of the wall.

If the length or number of M8x80 expansion bolts supplied with the SUN2000L is not enough, prepare
M8 stainless steel expansion anchor bolts.

Figure 4-9 Expansion bolt composition

(1) Bolt (2) Nut (3) Spring washer


(4) Flat washer (5) Expansion sleeve

 To prevent dust inhalation or contact with eyes, wear safety goggles and an anti-dust
respirator when drilling holes.
 Clean up any dust in and around the holes using a vacuum cleaner and measure the
distance between holes. If the holes are inaccurately positioned, drill a new set of the
holes.
 Level the head of the expansion sleeve with the concrete wall after removing the bolt,
spring washer, and flat washer. Otherwise, the mounting bracket will not be securely
installed on the concrete wall.

Figure 4-10 Installing an expansion bolt

Step 3 Secure the mounting bracket.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 26


SUN2000L-(2KTL-5KTL)
User Manual 4 System Installation

Figure 4-11 Securing a mounting bracket

----End

4.4.2 Support-mounted Installation


Prerequisites
Prepare M8 stainless bolt assemblies (including flat washers, spring washers, and M8 bolts)
with appropriate lengths as well as matched flat washers and nuts based on the support
specifications.

Procedure
Step 1 Determine the positions for drilling holes using the mounting bracket. Level the positions of
mounting holes using a bubble or digital level, and mark the positions with a marker.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 27


SUN2000L-(2KTL-5KTL)
User Manual 4 System Installation

Figure 4-12 Determining hole positions

Step 2 Drill holes using a hammer drill.

You are advised to apply anti-rust paint on the hole positions for protection.

Figure 4-13 Drilling holes

Step 3 Secure the mounting bracket.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 28


SUN2000L-(2KTL-5KTL)
User Manual 4 System Installation

Figure 4-14 Securing a mounting bracket

----End

4.5 Installing the SUN2000L


Procedure
Step 1 Hold the handles on both sides of the SUN2000L, lift the SUN2000L from the packing case,
and move it to the installation position.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 29


SUN2000L-(2KTL-5KTL)
User Manual 4 System Installation

 To prevent device damage and personal injury, keep balance when moving the SUN2000L.
 Do not use the wiring terminals and ports at the bottom to support any weight of the
SUN2000L.
 When you need to temporally place the SUN2000L on the ground, use foam, paper or
other protection materials to prevent damage to its cover.

Figure 4-15 Moving a SUN2000L

Step 2 Install the SUN2000L on the mounting bracket and align the SUN2000L enclosure with the
mounting bracket.

If the bottom of the mounting plate does not snap into place, push the SUN2000L from the
front until the bottom of the mounting plate snaps into the mounting bracket.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 30


SUN2000L-(2KTL-5KTL)
User Manual 4 System Installation

Figure 4-16 Mounting a SUN2000L

Step 3 Tighten screw assemblies.


Fixing holes can be used in three combinations. Select a hole combination based on site
requirements. Combination A is preferred.

Figure 4-17 Fixing holes

Combination A: holes 2 and 3 Combination B: holes 1 and 3


Combination C: holes 1 and 4 Combination D: holes 2 and 4

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 31


SUN2000L-(2KTL-5KTL)
User Manual 4 System Installation

Figure 4-18 Tightening screw assemblies

Step 4 (Optional) Install an anti-theft lock.


The function of an anti-theft lock is to secure the SUN2000L to the mounting bracket and
protect it from being stolen.

 Use an anti-theft lock suitable for the lock hole diameter (Ф8 mm). The anti-theft lock is
supplied by the customer.
 Keep the key to the anti-theft lock safe.

Figure 4-19 Installing an anti-theft lock

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 32


SUN2000L-(2KTL-5KTL)
User Manual 4 System Installation

----End

4.6 Installing the WiFi Antenna


Procedure
Step 1 Remove the watertight cap from the ANT port.
Step 2 Remove the release paper of the double-sided tape and attach the washer to the enclosure.
Step 3 Install the WiFi antenna.

Ensure that the WiFi antenna is installed securely.

Figure 4-20 Installing a WiFi antenna

----End

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 33


SUN2000L-(2KTL-5KTL)
User Manual 5 Electrical Connections

5 Electrical Connections

Precautions

Before connecting cables, ensure that the DC switch on the SUN2000L and all the switches
connecting to the SUN2000L are OFF. Otherwise, the high voltage of the SUN2000L may
result in electric shocks.

 The equipment damage caused by incorrect cable connections is beyond the warranty
scope.
 Only certified electricians are allowed to connect cables.
 Operation personnel must wear proper PPE when connecting cables.

The cable colors shown in the electrical connection diagrams provided in this chapter are for reference
only. Select cables in accordance with local cable specifications (green-and-yellow cables are only used
for PE).

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 34


SUN2000L-(2KTL-5KTL)
User Manual 5 Electrical Connections

5.1 Preparing Cables


Figure 5-1 Network diagram (dashed boxes indicate optional components)

indicates a power cable, indicates the power flow direction, and indicates a signal
cable.

(A) PV string (B) DC switch (C) SUN2000L


(D) AC switch (E) Power distribution unit (F) Smart Power Sensor
(G) Power meter (H) Power grid (I) Battery
(J) Battery switch (K) Alarm beacon (L) Residential load

Figure 5-2 SUN2000L cable connections (dashed boxes indicate optional components)

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 35


SUN2000L-(2KTL-5KTL)
User Manual 5 Electrical Connections

Table 5-1 Component description

No. Component Description Source

A PV string  A PV string is composed of the Purchased by the customer


PV modules connected in series
and works with an optimizer.
 The SUN2000L supports the
input from two PV strings.
B DC switch Recommended: a DC circuit Purchased by the customer
breaker with a rated voltage greater
than or equal to 600 V DC and a
rated current of 20 A
C Battery The batteries that can connect to the Purchased by the customer
SUN2000L are LG-RESU (LG
RESU7H and RESU10H).
D Battery switch Recommended: a DC circuit Purchased by the customer
breaker with a rated voltage greater
than or equal to 600 V DC and a
rated current of 20 A
E Smart Power Sensora The Smart Power Sensors that can Can be purchased from
connect to the SUN2000L are Huawei
DDSU666-H and DTSU666-H.
The Smart Power Sensors that can Purchased by the customer
connect to the SUN2000L are
CCS-WNC-3Y-400-MB,
Gavazzi-EM112DINAV01XS1X08,
Gavazzi-EM340DINAV23XS1X08
and
Gavazzi-EM111DINAV81XS1X08.
F Alarm beacon The rated voltage is 12 V and the Purchased by the customer
power is less than or equal to 3 W.
G AC switch Recommended: a single-phase AC Purchased by the customer
circuit breaker with a rated voltage
greater than or equal to 250 V AC
and a rated current of
 16 A (SUN2000L-2KTL)
 25 A (SUN2000L-3KTL and
SUN2000L-3.68KTL)
 32 A (SUN2000L-4KTL,
SUN2000L-4.6KTL, and
SUN2000L-5KTL)
Note a: Only the DDSU666-H Smart Sower Sensor (provided by Huawei) can be used in Spain.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 36


SUN2000L-(2KTL-5KTL)
User Manual 5 Electrical Connections

 The SUN2000L is embedded with a residual current monitoring unit (RCMU). Only a
single-phase circuit breaker or a similar AC load breaking device is required to function as
the external AC switch (shown by G in Figure 5-2) to ensure that the SUN2000L can be
safely disconnected from the power grid.
 If the external AC switch can perform earth leakage protection, the rated leakage action
current should be greater than or equal to 100 mA.
 If multiple SUN2000Ls connect to the general residual current device (RCD) through their
respective external AC switches, the rated leakage action current of the general RCD
should be greater than or equal to the number of SUN2000Ls multiplied by 100 mA.
 A knife switch cannot be used as an AC switch.

Table 5-2 Cable description

No. Cable Type Conductor Outer Source


Cross-sectional Diameter
Area Range

1 DC input Standard PV cable in the 4–6 mm2 4.5–7.8 mm Purchased by


power cable industry (recommended the customer
model: PV1-F)
2 Battery cable Standard PV cable in the 4–6 mm2 4.5–7.8 mm Purchased by
industry (recommended the customer
model: PV1-F)
3 Signal cable Four-core outdoor shielded 0.25–1 mm2 4–11 mm Purchased by
twisted pair cable the customer
4 AC output  Not using the PE 4–6 mm2 10–21 mm Purchased by
power cable equipotential point at the the customer
AC output port: two-core
(L and N) outdoor copper
cable
 Using the PE
equipotential point at the
AC output port:
three-core (L, N, and PE)
outdoor copper cable
5 PE cable Single-core outdoor copper 4–10 mm2 N/A Purchased by
cable with an M6 OT the customer
terminal

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 37


SUN2000L-(2KTL-5KTL)
User Manual 5 Electrical Connections

 The PE point at the AC output port is used only as a PE equipotential point, and cannot
substitute for the PE point on the enclosure.
 When installing cables, ensure that the AC output power cable and PE cable are close to
each other.
 When installing cables, ensure that the AC output power cable and DC input power cables
are close to each other.
 When installing DC input power cables, ensure that the PV+ and PV– cables are close to
each other.

5.2 Installing the PE Cable


Context

Do not connect the neutral wire to the enclosure as a PE cable. Otherwise, electric shocks
could occur.

Procedure
Step 1 Crimp the OT terminal.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 38


SUN2000L-(2KTL-5KTL)
User Manual 5 Electrical Connections

 Pay attention not to damage the core wire when stripping a cable.
 The cavity formed after the conductor crimp strip of the OT terminal is crimped must wrap
the core wires completely. The core wires must contact the OT terminal closely.
 Wrap the wire crimping area with heat shrink tubing or PVC insulation tape. The
following figure uses heat shrink tubing as an example.
 When using the heat gun, protect devices from being scorched.

Figure 5-3 Crimping an OT terminal

(A) Core wire (B) Insulation layer (C) Heat shrink tubing
(D) Hydraulic pliers (E) Heat gun

Step 2 Connect the PE cable.

Ensure that the PE cable is connected securely.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 39


SUN2000L-(2KTL-5KTL)
User Manual 5 Electrical Connections

Figure 5-4 Connecting a PE cable

 The PE point at the AC output port is used only as a PE equipotential point, and cannot substitute for
the PE point on the enclosure.
 To enhance the corrosion resistance of a ground terminal, apply silica gel or paint around the
terminal after connecting the PE cable.

----End

5.3 Installing the AC Output Power Cable


Prerequisites
An AC switch must be installed on the AC side of the SUN2000L to ensure that the
SUN2000L can be safely disconnected from the power grid.

Do not connect any load between the SUN2000L and the AC switch.

Context
The SUN2000L can detect the grounding. This function is used to detect whether the
SUN2000L is properly grounded before starting it, or to detect whether the PE cable is
disconnected when the SUN2000L is working. This function is available only under limited
conditions. To ensure the safe operation of the SUN2000L, properly ground the SUN2000L in
strict accordance with the connection requirements for PE cables. For certain types of power
grids, if an isolation transformer connects to the output side of the SUN2000L, you need to set
Grounding inspection to Disable after checking that the SUN2000L is properly grounded.
Then the SUN2000L can start normally. If you are not sure whether the SUN2000L connects
to such a power grid, confirm it with your supplier or Huawei technical support.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 40


SUN2000L-(2KTL-5KTL)
User Manual 5 Electrical Connections

 According to IEC62109, to ensure the safe operation of the SUN2000L in the case of PE cable
damage or disconnection, connect the SUN2000L PE cable according to the requirements described
in 5.2 Installing the PE Cable and ensure that the SUN2000L PE cable meets at least one of the
following requirements before disabling the grounding detection function.
The SUN2000L PE cable is a copper cable with a cross-sectional area of at least 10 mm2.
Use two cables that have the same diameter as the AC output power cable to ground the PE terminal
on the AC connector and the ground screw on the enclosure respectively (see 5.2 Installing the PE
Cable and 5.3 Installing the AC Output Power Cable for details).
 Certain countries require an additional PE cable for the SUN2000L. In this case, use two cables that
have the same diameter as the AC output power cable to ground the PE terminal on the AC
connector and the ground screw on the enclosure respectively (see 5.2 Installing the PE Cable and
5.3 Installing the AC Output Power Cable for details).

Procedure
Step 1 Connect the AC output power cable to the AC connector.

 Ensure that the cable jacket is inside the connector.


 Ensure that the exposed core wire is totally inserted into the cable hole.
 Ensure that AC terminations provide firm and solid electrical connections. Failing to do so
may cause SUN2000L malfunction and damage to its AC connectors.
 Ensure that the cable is not twisted.

Figure 5-5 Assembling an AC connector (three-core wire)

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 41


SUN2000L-(2KTL-5KTL)
User Manual 5 Electrical Connections

Figure 5-6 Assembling an AC connector (two-core wire)

 The cable colors shown in figures are for reference only. Select an appropriate cable according to the
local standards.
 For the core wire installation method and stripped length, see the instructions on the side of the plug
insert.

Figure 5-7 Stripped length

Step 2 Connect the AC connector to the AC output port.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 42


SUN2000L-(2KTL-5KTL)
User Manual 5 Electrical Connections

Ensure that the AC connector is connected securely.

Figure 5-8 Securing an AC connector

Step 3 Check the route of the AC output power cable.

Figure 5-9 Cable route

----End

Follow-up Procedure

Before removing the AC connector, ensure that the DC switch at the bottom of the SUN2000L
and all the switches connecting to the SUN2000L are OFF.

To remove the AC connector from the SUN2000L, perform the operations in reverse order.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 43


SUN2000L-(2KTL-5KTL)
User Manual 5 Electrical Connections

Figure 5-10 Removing a plug insert

5.4 Installing the DC Input Power Cable


Prerequisites

 Before connecting the DC input power cable, ensure that the DC voltage is within the safe
range (lower than 60 V DC) and that the DC switch on the SUN2000L is OFF. Failing to
do so may result in electric shocks.
 When the SUN2000L is operating, it is not allowed to work on DC circuit, such as
connecting or disconnecting a PV string or a PV module in a PV string. Failing to do so
may cause electric shocks.
 If no PV string connects to the DC input terminals, do not remove the watertight cap from
the DC input terminals. Otherwise, the SUN2000L will not comply with its Ingress
Protection Rating.

Ensure that the following conditions are met. Otherwise, the SUN2000L will be damaged, or
even become a fire hazard.
 The open-circuit voltage of each PV string is always lower than or equal to 600 V DC.
 The positive and negative terminals of a PV string connect to corresponding positive and
negative DC input terminals of the SUN2000L.
 If polarity of the DC input power cable is reversed and the DC switch is ON, do not turn
off the DC switch immediately or unplug positive and negative connectors. Wait until the
solar irradiance declines at night and the PV string current reduces to below 0.5 A, and
then turn off the DC switch and remove the positive and negative connectors. Correct the
string polarity before reconnecting the string to the SUN2000L.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 44


SUN2000L-(2KTL-5KTL)
User Manual 5 Electrical Connections

 The PV terminal of the inverter supports only the PV string input and cannot be connected
to other power supplies. Since the output of the PV string connected to the SUN2000L
cannot be grounded, ensure that the PV module output is well insulated to ground.
 During the installation of PV strings and SUN2000L, the positive or negative terminals of
PV strings may be grounded if power cables are not properly installed or routed. In this
case, an AC or DC short circuit may occur and damage the SUN2000L. This damage is not
covered under any warranty.

Context

Figure 5-11 DC input terminals

(1) The first set of DC input terminals (2) The second set of DC input terminals

Procedure
Step 1 Assemble the black positive and negative connectors.

Use the positive and negative metal contacts and DC connectors supplied with the SUN2000L.
Using incompatible positive and negative metal contacts and DC connectors may result in
serious consequences. The caused device damage is not covered under any warranty.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 45


SUN2000L-(2KTL-5KTL)
User Manual 5 Electrical Connections

 Cables with high rigidity, such as armored cables, are not recommended as DC input
power cables, because poor contact may be caused by the bending of the cables.
 The metal contacts supplied with the DC connectors are either cold forming contacts or
stamping forming contacts. Crimp the metal cold forming contacts using crimping tool
UTXTC0005 (Amphenol, recommended) or H4TC0001 (Amphenol). Crimp the metal
stamping forming contacts using crimping tool H4TC0003 (Amphenol, recommended) or
H4TC0002 (Amphenol).
 DC terminal model (cold forming metal terminal): straight male HH4CMD5TM and
straight female HH4CFC5DM; DC terminal model (stamping forming metal terminal):
straight male HH4CMD4TMS and straight female HH4CFD4TMS.
 Before assembling DC input connectors, label the cable polarities correctly to ensure
correct cable connections.
 After crimping the positive and negative metal contacts, pull the DC input power cables
back to check that they are connected securely.
 Insert the crimped metal contacts of the positive and negative power cables into the
corresponding positive and negative connectors. Then pull back the DC input power cables
to check that they are connected securely.

Figure 5-12 Assembling DC connectors (using metal cold forming contacts)

(A) Positive metal contact (B) Negative metal contact (C) UTXTC0005 crimping tool
(D) Positive connector (E) Negative connector (F) H4TW0001 open-end wrench

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 46


SUN2000L-(2KTL-5KTL)
User Manual 5 Electrical Connections

Figure 5-13 Assembling DC connectors (using metal stamping forming contacts)

(A) Positive metal contact (B) Negative metal contact (C) H4TC0003 crimping tool
(D) Positive connector (E) Negative connector (F) H4TW0001 open-end wrench

Ensure that the core wires can be seen through the hole on the terminal both before and after
the positive and negative metal terminals are crimped.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 47


SUN2000L-(2KTL-5KTL)
User Manual 5 Electrical Connections

Figure 5-14 Observing core wires through the hole on the terminal

Step 2 Ensure that the DC input voltage of each PV string is within the specified range of the
SUN2000L using a multimeter and check that the polarities of DC input power cables are
correct.

Figure 5-15 Measuring the DC input voltage

Before performing Step 3, ensure that the DC switch is OFF.

Step 3 Insert the positive and negative connectors into corresponding DC input terminals on the
SUN2000L.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 48


SUN2000L-(2KTL-5KTL)
User Manual 5 Electrical Connections

After the positive and negative connectors snap into place, pull the DC input power cables
back to check that they are connected securely.

Figure 5-16 Connecting DC input power cables

If polarity of the DC input power cable is reversed and the DC switch is ON, do not turn off
the DC switch immediately or unplug positive and negative connectors. The device may be
damaged if you do not follow the instruction. This damage is not covered under any warranty.
Wait until the solar irradiance declines at night and the PV string current reduces to below 0.5
A, and then turn off the DC switch and remove the positive and negative connectors. Correct
the string polarity before reconnecting the string to the SUN2000L.

----End

Follow-up Procedure

Before removing the positive and negative connectors, ensure that the DC switch is OFF.

To remove the positive and negative connectors from the SUN2000L, insert an open-end
wrench into the notch and press the wrench with an appropriate force.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 49


SUN2000L-(2KTL-5KTL)
User Manual 5 Electrical Connections

Figure 5-17 Removing a DC connector

5.5 Installing Battery Cables


Prerequisites

 Battery short circuits may cause personal injury. The high transient current generated by a
short circuit will release a surge of power and may even cause fire.
 Do not connect or disconnect battery cables when the SUN2000L is running. Failing to do
so may cause electric shocks.
 Before connecting battery cables, ensure that the DC switch on the SUN2000L and all the
switches connecting to the SUN2000L are OFF, and the SUN2000L has no residual
electricity. Otherwise, the high voltage of the SUN2000L and battery may result in electric
shocks.
 If no battery connects to the SUN2000L, do not remove the watertight cap from the battery
terminal. Otherwise, the SUN2000L will not comply with its Ingress Protection Rating. If
a battery connects to the SUN2000L, set aside the watertight cap. Reinstall the watertight
cap immediately after removing the connector. The high voltage of the battery terminal
may result in electric shocks.

A battery switch can be configured between the SUN2000L and the battery to ensure that the
SUN2000L can be safely disconnected from the battery.

Do not connect any load between the SUN2000L and the battery.
Ensure that the following conditions are met. Otherwise, the SUN2000L will be damaged, or
even become a fire hazard.
The battery cables should be connected correctly. That is, the positive and negative terminals
of the battery connect to the positive and negative battery terminals on the SUN2000L
respectively.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 50


SUN2000L-(2KTL-5KTL)
User Manual 5 Electrical Connections

 During the installation of the SUN2000L and battery, the positive or negative terminal of
the battery will be short-circuited to ground if power cables are not installed or routed as
required. In this case, an AC or DC short circuit may occur and damage the SUN2000L.
This damage is not covered under any warranty or service agreement.
 The cables between the battery and the SUN2000L should be less than or equal to 10
meters, and within 5 meters is recommended.

Procedure
Step 1 Assemble the blue positive and negative connectors by following the instructions in 5.4
Installing the DC Input Power Cable.

 The battery voltage will result in serious injury. Use dedicated insulation tools to connect
cables.
 Ensure that cables are correctly connected between the battery terminal and the battery
switch, and between the battery switch and the SUN2000L battery terminal.

Cables with high rigidity, such as armored cables, are not recommended, because poor contact
may be caused by the bending of the cables.

Step 2 Insert the positive and negative connectors into corresponding battery terminals on the
SUN2000L.

After the positive and negative connectors snap into place, pull the battery cables back to
check that they are secured.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 51


SUN2000L-(2KTL-5KTL)
User Manual 5 Electrical Connections

Figure 5-18 Installing battery cables

----End

5.6 Installing the Signal Cable


Context

When laying out signal cables, separate them from power cables to avoid strong signal
interference sources.

Figure 5-19 Signal Cable Ports

Signal cable ports are classified into COM ports and ALARM ports.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 52


SUN2000L-(2KTL-5KTL)
User Manual 5 Electrical Connections

Figure 5-20 COM Ports

The COM port provides two RS485 communications ports and one enable signal port to
connect to Smart Power Sensors, batteries, and so on.

Table 5-3 COM port definitions

No. Label Definition Description

1 485B1 RS485B, RS485 differential Reserved, can connect to the


signal– RS485 signal port on the
Smart Power Sensor.
2 485A1 RS485A, RS485 differential
signal+
3 485B2 RS485B, RS485 differential Reserved, can connect to the
signal– RS485 signal port and
enable signal port on a
4 485A2 RS485A, RS485 differential battery.
signal+
5 EN– Enable signal–
6 EN+ Enable signal+
7 N/A N/A N/A
8 PE Shielding ground Connects to the shield layer
of the cable.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 53


SUN2000L-(2KTL-5KTL)
User Manual 5 Electrical Connections

Figure 5-21 ALARM Ports

The ALARM port provides an alarm signal port to connect to an alarm beacon, which reminds
the user to handle the Low Insulation Resistance, Abnormal Residual Current, or Faulty
Residual Current Sensor alarm. The ALARM port reserves an RS485/12 V signal port.

 The alarm beacon should be installed within 2 meters away from the SUN2000L.
 The shield layer of the device signal cable connected to the ALARM port and the COM
port is also advised to be grounded.
 The Faulty Residual Current Sensor alarm is the Abnormal Device alarm with a cause
ID of 5.

Table 5-4 ALARM port definitions

No. Label Definition Description

1 ALARM– Alarm signal– Reserved, can connect to the


power port on an alarm
2 ALARM+ Alarm signal+ beacon
3 485B3 RS485B, RS485 differential Reserved RS485/12 V
signal– signal port, output power of
the 12 V power supply ≤ 3
4 485A3 RS485A, RS485 differential W
signal+
5 12 V– Negative of the 12 V power supply
6 12 V+ Positive of the 12 V power supply
7 N/A N/A N/A
8 PE Shielding ground Connects to the shield layer
of the cable.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 54


SUN2000L-(2KTL-5KTL)
User Manual 5 Electrical Connections

Procedure
Step 1 Connect signal cables to appropriate signal connectors.

 The protection layer of the cable is in the connector. Surplus core wires are cut off from
the protection layer.
 Ensure that the exposed core wire is totally inserted into the cable hole.
 Ensure that the signal cables are connected securely.
 Ensure that the cable is not twisted.
 If a connector needs to connect to only one signal cable, block the unused cable hole on
the seal using a waterproofing bolt and tighten the sealing nut.
 If a connector needs to connect to two signal cables, ensure that the cables have the same
outer diameter.

Figure 5-22 Assembling a signal connector (COM port)

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 55


SUN2000L-(2KTL-5KTL)
User Manual 5 Electrical Connections

Figure 5-23 Assembling a signal connector (ALARM port)

Step 2 Connect the signal connector to the corresponding port.

 Do not confuse the connector to the COM port with that of ALARM port.
 Ensure that the signal connector is connected securely.

Figure 5-24 Securing a connector (COM port)

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 56


SUN2000L-(2KTL-5KTL)
User Manual 5 Electrical Connections

Figure 5-25 Securing a connector (ALARM port)

----End

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 57


SUN2000L-(2KTL-5KTL)
User Manual 6 System Commissioning

6 System Commissioning

6.1 Checking Before Power-On


Table 6-1 Installation checklist
No. Check Item Acceptance Criteria

1 SUN2000L installation The SUN2000L is installed correctly,


securely, and reliably.
2 WiFi antenna installation The WiFi antenna is installed correctly,
securely, and reliably.
3 Cable layout Cables are routed properly as required by the
customer.
4 Cable tie Cable ties are secured evenly and no burr
exists.
5 Grounding The ground cable is connected correctly,
securely, and reliably.
6 Switch status The DC switch and all the switches
connecting to the SUN2000L are OFF.
7 Cable connections The AC output power cable, DC input power
cable, battery cable, and signal cable are
connected correctly, securely, and reliably.
8 Unused terminals and ports Unused terminals and ports are blocked by
watertight caps.
9 Installation environment The installation space is proper, and the
installation environment is clean and tidy,
without foreign matter.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 58


SUN2000L-(2KTL-5KTL)
User Manual 6 System Commissioning

6.2 Powering On the System


Prerequisites
Before turning on the AC switch between the SUN2000L and the power grid, check that the
AC voltage on the power grid side of the AC switch is within the specified range.

 If the DC is on and the AC is off, the SUN2000L reports a Grid Loss alarm. The
SUN2000L starts normally only after the fault is rectified.
 If the AC is on and the battery is off, the SUN2000L reports a Battery Abnormal alarm.
 If the inverters are connected to batteries, turn on the DC switch within 1 minute after
turning on the AC switch. Otherwise, the inverters, connected to the power grid, will shut
down and start again.

Procedure
Step 1 If a battery connects to the battery port, turn on the battery Auxiliary Power ON/OFF switch,
and then turn on the battery Circuit Breaker switch.
Step 2 Turn on the AC switch between the SUN2000L and the power grid.
Step 3 Turn on the DC switch between the PV string and the SUN2000L if there is any.
Step 4 Turn on the DC switch at the bottom of the SUN2000L.
Step 5 Observe the LEDs to check the SUN2000L operating status.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 59


SUN2000L-(2KTL-5KTL)
User Manual 6 System Commissioning

Table 6-2 LED description

Type Status Meaning

Running LED 1 LED 2 N/A


indication
Steady green Steady green The SUN2000L is exporting
power to the power grid.
Blinking green at Off The DC is on and the AC is
long intervals (on off.
for 1s and then
off for 1s)
Off Blinking green at The DC is off and the AC is
long intervals (on on.
for 1s and then
off for 1s)
Blinking green at Blinking green at The DC is on, the AC is on,
long intervals (on long intervals (on and the SUN2000L is not
for 1s and then for 1s and then exporting power to the power
off for 1s) off for 1s) grid.
Off Off Both the DC and AC are off,
or the SUN2000L is in Low
Power Consumption mode.
Low Power Consumption
mode means that the
monitoring system of the
SUN2000L is hibernating.
Steady red Steady red The SUN2000L is faulty.

Communication LED 3 N/A


indication
Blinking green at short intervals (on Communicating
for 0.2s and then off for 0.2s) (Communicating means that
the communication with the
upper-level management unit
is in progress. However, if a
mobile phone accesses the
SUN2000L, the LED
indicates the "mobile phone
access status: blinking green
at long intervals" first.)
Blinking green at long intervals (on The mobile phone is
for 1s and then off for 1s) connected to the SUN2000L.
Off No communication

----End

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 60


SUN2000L-(2KTL-5KTL)
User Manual 6 System Commissioning

6.3 Commissioning
6.3.1 Scenario 1: Commissioning Through Setup Wizard
Downloading the App
Search for "FusionSolar" from the following app stores or scan the corresponding QR code,
download the installation package, and install the FusionSolar app by following the
instructions.
 Google Play (Android)
 App Store (iOS)

Figure 6-1 QR code

 The screenshots shown in the document are from FusionSolar V2.3.0. Data in the screenshots is for
reference only. The actual screens prevail.
 The initial password for connecting the inverter WiFi is Changeme
 The initial password of the installer is 00000a.
 Use the initial password upon first power-on and change it immediately after login. To ensure
account security, change the password periodically and keep the new password in mind. Not
changing the initial password may cause password disclosure. A password left unchanged for a long
period of time may be stolen or cracked. If a password is lost, devices cannot be accessed. In these
cases, the user is liable for any loss caused to the PV plant.

(Optional) Installer Account Registration


Creating the first installer account will generate a domain named after the company.

If you have an installer account, skip this step.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 61


SUN2000L-(2KTL-5KTL)
User Manual 6 System Commissioning

Figure 6-2 Creating the first installer account

To create multiple installer accounts for the same company, log in to the FusionSolar app and
tap New User.

Figure 6-3 Creating multiple installer accounts for the same company

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 62


SUN2000L-(2KTL-5KTL)
User Manual 6 System Commissioning

Creating a PV Plant and an Account for User

Figure 6-4 Creating a PV Plant and an Account for User

For details, see the FusionSolar App Quick Guide.


You can scan the QR code to obtain it.

6.3.2 Scenario 2: Device Commissioning


1. Access Device commissioning.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 63


SUN2000L-(2KTL-5KTL)
User Manual 6 System Commissioning

Figure 6-5 Method 1: before login

Figure 6-6 Method 2: after login

2. Connect to the inverter WiFi. Log in as installer, and perform Quick settings.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 64


SUN2000L-(2KTL-5KTL)
User Manual 6 System Commissioning

Figure 6-7 Quick settings

 The initial password for connecting the inverter WiFi is Changeme


 The initial password of the installer is 00000a
 Use the initial password upon first power-on and change it immediately after login. To ensure
account security, change the password periodically and keep the new password in mind. Not
changing the initial password may cause password disclosure. A password left unchanged for a long
period of time may be stolen or cracked. If a password is lost, devices cannot be accessed. In these
cases, the user is liable for any loss caused to the PV plant.
 To set more parameters, tap Parameter configuration.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 65


SUN2000L-(2KTL-5KTL)
User Manual 6 System Commissioning

6.4 Energy Control


On the Home screen, choose Device maintenance > Energy control and perform the
corresponding operation.

Figure 6-8 Energy control

6.4.1 Grid-tied Point Control


Procedure
Step 1 On the Home screen, choose Device maintenance > Energy control > Grid-tied point
control and perform the required operation.

Figure 6-9 Grid-tied point control

Table 6-3 Description of control mode parameters

Parameter Description Value Range

Control mode If this parameter is set to  Not restricted


Not restricted, the  Grid connected with zero
SUN2000L output power is power
not limited. The SUN2000L
 Power-limited Grid
can export its rated power to
the power grid. Connected
If this parameter is set to
Grid connected with zero
power and the SUN2000L
is connected to a power

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 66


SUN2000L-(2KTL-5KTL)
User Manual 6 System Commissioning

Parameter Description Value Range


meter, the output power of
the SUN2000L is supplied
only to the local load, but
not the power grid.
If this parameter is set to
Power-limited Grid
Connected and the
SUN2000L is connected to a
power meter, the
SUN2000L supplies power
limited based on the setting
of Grid-tied Point Power
to the power grid.

----End

6.4.2 Energy Storage Control


Forcible Charge/Discharge
Step 1 On the Home screen, choose Device maintenance > Energy control > Energy storage
control > Forcible charge/discharge and perform operations as required.

Figure 6-10 Forcible charge/discharge

Table 6-4 Description of forced charge/discharge parameters

Parameter Description Value Range

Charge/discharge power The battery is charging or  Stop


discharging when the  Charge
command is set.
 Discharge
Forced charge/discharge Specifies the forced  Charge: [0, Maximum
power (kW) charge/discharge power. charge power]
 Discharge: [0, Maximum

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 67


SUN2000L-(2KTL-5KTL)
User Manual 6 System Commissioning

Parameter Description Value Range


discharge power]
Forced charge/discharge Specifies the forced [0, 1440]
period (mins) charge/discharge duration.
Remaining charge/discharge Displays the remaining [0, 1440]
time (mins) charge/discharge time. This
parameter cannot be set.

----End

Control Mode
Step 1 On the Home screen, choose Device maintenance > Energy control > Energy storage
control > Control mode and perform the required operation.

Figure 6-11 Fixed charge/discharge

Figure 6-12 Maximise self consumption

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 68


SUN2000L-(2KTL-5KTL)
User Manual 6 System Commissioning

Figure 6-13 Time-of-use price

Table 6-5 Description of energy storage control parameters

Parameter Description Value Range

Control mode  If this parameter is set to  Fixed charge/discharge


Fixed charge/discharge,  Maximise self
the battery is charging or consumption
discharging during the
 Time-of-use price
configured period. A
maximum of 10 time
periods can be added.
 If this parameter is set to
Maximise self
consumption and the
SUN2000L is connected
to a power meter, the
battery is charging when
the PV power is more
than the local load. The
battery is discharging
when the PV power is
less than the local load.
 If this parameter is set to
Time-of-use price, the
battery is discharged
when the electricity price
is high and charged
when the electricity price
is low. A maximum of
10 price time periods can
be added.

----End

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 69


SUN2000L-(2KTL-5KTL)
User Manual 6 System Commissioning

Grid Charge
Step 1 On the Home screen, choose Device maintenance > Energy control > Energy storage
control > Grid charge and perform the required operation.

Figure 6-14 Grid charge

Table 6-6 Parameter description of Grid charge

Parameter Description Value Range

Grid charge The power grid will charge  Disable


the battery if Grid charge is  Enable
enabled.
If Grid charge function is
disabled by default, comply
with the grid charge
requirements stipulated in
local laws and regulations
when this function is
enabled.

----End

6.5 IPS Test (for Italy CEI0-21 Grid Code only)


Context
The Italy CEI0-21 grid code requires IPS check for the SUN2000L. During the self-check
process, the SUN2000L consecutively checks the protection thresholds and time for 10-min
overvoltage, level 1 overvoltage, level 1 undervoltage, level 1 overfrequency, and level 1
underfrequency. The SUN2000L shuts down after the check starts, and it restarts after the
check is successful.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 70


SUN2000L-(2KTL-5KTL)
User Manual 6 System Commissioning

Procedure
Step 1 On the Home screen, choose Device maintenance > IPS test to access the IPS test screen.

Figure 6-15 IPS test

Step 2 Choose to start the S1 or S2 check as required. The default check type is S2. To start the S2
check, you need to set External Signal or Local Command.

Table 6-7 Check type description


Check Type Description External Signal Local Command
Setting Setting

S1 The level 1
overfrequency
protection threshold
is 50.5 Hz and the
level 1
underfrequency
protection threshold
is 49.5 Hz.
S2 The level 1
overfrequency
protection threshold
is 51.5 Hz and the
level 1
underfrequency

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 71


SUN2000L-(2KTL-5KTL)
User Manual 6 System Commissioning

Check Type Description External Signal Local Command


Setting Setting
protection threshold
is 47.5 Hz.
S2 (default) The level 1
overfrequency
protection threshold
is 51.5 Hz and the
level 1
underfrequency
protection threshold
is 47.5 Hz.
S2 The level 1
overfrequency
protection threshold
is 51.5 Hz and the
level 1
underfrequency
protection threshold
is 47.5 Hz.

Step 3 Tap Start to start the check. After the check is complete, IPS State is displayed as Self-test
success.
----End

6.6 Powering Off the System


Context

 After the SUN2000L is powered off, the remaining electricity and heat may still cause
electric shocks and body burns. Therefore, put on protective gloves and operate the
SUN2000L 5 minutes after the power-off.
 If the SUN2000L is connected to the battery, ensure that a shutdown command is sent
from the app. Power off the system after the SUN2000L has shut down. If no shutdown
command is sent from the app, the SUN2000L will shut down after the power grid is
powered off. Then, the SUN2000L will wait for 1 minute and restart (not grid-tied) to
charge the battery, which poses the risk of turning off the DC switch with power.

Procedure
Step 1 Send a shutdown command from the app.
Step 2 Turn off the AC switch between the SUN2000L and the power grid.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 72


SUN2000L-(2KTL-5KTL)
User Manual 6 System Commissioning

Step 3 Turn off the DC switch at the bottom of the SUN2000L.


Step 4 Turn off the DC switch between the PV string and the SUN2000L if there is any.
Step 5 If a battery connects to the battery port, turn off the battery switch.
----End

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 73


SUN2000L-(2KTL-5KTL)
User Manual 7 System Maintenance

7 System Maintenance

7.1 Routine Maintenance


To ensure that the SUN2000L can operate properly in the long term, you are advised to
perform routine maintenance on it as described in this chapter.

Before cleaning the system, connecting cables, and maintaining the grounding reliability,
power off the system (see 6.3 Powering Off the System for details).

Table 7-1 Maintenance checklist

Check Item Acceptance Criteria Maintenance


Interval

System The heat sinks are free from obstacles or Once every 6 to 12
cleanliness dust. months
System running  The SUN2000L is not damaged or Once every 6 months
status deformed.
 The SUN2000L operates with no
abnormal sound.
 All SUN2000L parameters are correctly
set. Perform this check when the
SUN2000L is running.
Electrical  Cables are securely connected. Perform the first
connections  Cables are intact, and in particular, the maintenance 6 months
cable jackets touching the metallic after the initial
surface are not scratched. commissioning. From
then on, perform the
 Unused DC input terminals, battery maintenance once every
terminals, COM ports, ALARM ports, 6 to 12 months.
and ANT ports are locked by watertight
caps.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 74


SUN2000L-(2KTL-5KTL)
User Manual 7 System Maintenance

Check Item Acceptance Criteria Maintenance


Interval

Grounding Ground cables are securely connected. Perform the first


reliability maintenance 6 months
after the initial
commissioning. From
then on, perform the
maintenance once every
6 to 12 months.

7.2 Troubleshooting
Alarm severities are defined as follows:
 Major: The SUN2000L enters Shutdown mode and disconnects from the power grid to
stop generating power after a fault occurs.
 Minor: Some components are faulty but the SUN2000L can still connect to the power
grid and generate power.
 Warning: The SUN2000L output power decreases due to external factors.

Table 7-2 Common alarms and troubleshooting measures

Alarm Alarm Name Alarm Possible Cause Suggestion


ID Severity

2001 High String Input Major The PV array is incorrectly Reduce the number of PV
Voltage configured. Excessive PV modules connected in series to the
modules are connected in PV string until the PV string
series to the PV string, and open-circuit voltage is less than or
therefore the open-circuit equal to the maximum inverter
voltage exceeds the input voltage. After the PV array
maximum inverter input is correctly configured, the
voltage. inverter alarm disappears.
The following is the mapping
between PV strings and alarm
cause IDs:
 Cause ID 1: string 1
 Cause ID 2: string 2

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 75


SUN2000L-(2KTL-5KTL)
User Manual 7 System Maintenance

Alarm Alarm Name Alarm Possible Cause Suggestion


ID Severity

2011 String Reversed Major The PV string is reversely Check whether the PV string is
connected. reversely connected to the
SUN2000L. If so, wait until the
solar irradiance declines at night
and the PV string current reduces
to below 0.5 A. Then, turn off the
DC switch and correct the PV
string polarity.
The following is the mapping
between PV strings and alarm
cause IDs:
 Cause ID 1: string 1
 Cause ID 2: string 2
2032 Grid Failure Major Cause ID = 1 1. Check the AC voltage.
 The power grid 2. Check that the AC power
experiences an outage. cable is connected and that the
AC switch is ON.
 The AC circuit is
disconnected or AC
switch is off.
2033 Grid Major Cause ID = 1 1. If the alarm occurs
Undervoltage accidentally, the power grid
The grid voltage is below the
may be abnormal temporarily.
lower threshold or the low
The SUN2000L automatically
voltage duration has lasted
recovers after detecting that
for more than the value
the power grid becomes
specified by LVRT.
normal.
2. If the alarm occurs frequently,
check whether the grid voltage
is within the acceptable range.
If not, contact the local power
operator. If so, modify the
power grid undervoltage
protection thresholds with the
consent of the local power
operator.
3. If the fault persists for a long
time, check the connection
between the AC switch and the
output power cable.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 76


SUN2000L-(2KTL-5KTL)
User Manual 7 System Maintenance

Alarm Alarm Name Alarm Possible Cause Suggestion


ID Severity

2034 Grid Overvoltage Major Cause ID = 1 1. Check whether the grid


connection voltage exceeds the
The grid voltage exceeds the
upper threshold. If so, contact
higher threshold or the high
the local power operator.
voltage duration has lasted
for more than the value 2. If you have confirmed that the
specified by HVRT. grid connection voltage
exceeds the upper threshold
and obtained the consent of the
local power operator, modify
the overvoltage protection
thresholds.
3. Check whether the peak grid
voltage exceeds the upper
threshold.
2035 Unbalanced Grid Major The difference between grid 1. Check that the grid voltage is
Voltage phase voltages exceeds the within the normal range.
upper threshold. 2. Check the connection of the
AC output power cable.
3. If the cable connection is
proper but the alarm occurs
frequently and affects the
power production of the PV
plant, contact the local power
operator.
2036 Grid Major Cause ID = 1 1. If the alarm occurs
Overfrequency accidentally, the power grid
Power grid exception: The
may be abnormal temporarily.
actual grid frequency is
The SUN2000L automatically
higher than the local power
recovers after detecting that
grid standard.
the power grid becomes
normal.
2. If the alarm occurs frequently,
check whether the grid
frequency is within the
acceptable range. If not,
contact the local power
operator. If so, modify the grid
overfrequency protection
threshold with the consent of
the local power operator.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 77


SUN2000L-(2KTL-5KTL)
User Manual 7 System Maintenance

Alarm Alarm Name Alarm Possible Cause Suggestion


ID Severity

2037 Grid Major Cause ID = 1 1. If the alarm occurs


Underfrequency accidentally, the power grid
Power grid exception: The
may be abnormal temporarily.
actual grid frequency is
The SUN2000L automatically
lower than the local power
recovers after detecting that
grid standard.
the power grid becomes
normal.
2. If the alarm occurs frequently,
check whether the grid
frequency is within the
acceptable range. If not,
contact the local power
operator. If so, modify the grid
underfrequency protection
threshold with the consent of
the local power operator.
2038 Unstable Grid Major Cause ID = 1 1. If the alarm occurs
Frequency accidentally, the power grid
Power grid exception: The
may be abnormal temporarily.
actual grid frequency change
The SUN2000L automatically
rate does not comply with
recovers after detecting that
the local power grid
the power grid becomes
standard.
normal.
2. If the alarm occurs frequently,
check whether the grid
frequency is within the
acceptable range. If not,
contact the local power
operator.
2039 Output Major Cause ID = 1 1. The SUN2000L monitors its
Overcurrent external working conditions in
The grid voltage drops
real time. The SUN2000L
dramatically or the power
automatically recovers after
grid is short-circuited. As a
the fault is rectified.
result, the inverter transient
output current exceeds the 2. If the alarm occurs frequently
upper threshold and and affects the power
therefore the inverter production of the PV plant,
protection is triggered. check whether the output is
short-circuited. If the fault
persists, contact your supplier
or Huawei technical support.
2040 Output DC Major Cause ID = 1 1. The SUN2000L monitors its
Component external working conditions in
The DC component of the
Overhigh real time. The SUN2000L
SUN2000L output current
automatically recovers after
exceeds the specified upper
the fault is rectified.
threshold.
2. If the alarm occurs frequently,
contact your supplier or
Huawei technical support.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 78


SUN2000L-(2KTL-5KTL)
User Manual 7 System Maintenance

Alarm Alarm Name Alarm Possible Cause Suggestion


ID Severity

2051 Abnormal Major Cause ID = 1 1. If the alarm occurs


Residual Current accidentally, the external
The insulation impedance of
power cable may be abnormal
the input side to PE
temporarily. The SUN2000L
decreases when the
automatically recovers after
SUN2000L is operating.
the fault is rectified.
2. If the alarm occurs frequently
or persists, check whether the
impedance between the PV
string and ground is below the
lower threshold.
2061 Abnormal Major Cause ID = 1 1. Check that the PE cable for the
Grounding 
SUN2000L is connected
The PE cable for the
properly.
SUN2000L is not
connected. 2. Check that the voltage
between the SUN2000L
 The voltage between the neutral wire and ground is
SUN2000L neutral wire within the normal range. If an
and ground exceeds the isolation transformer is
upper threshold. connected, set OFF due to
abnormal grounding to
Disable.
2062 Low Insulation Major Cause ID = 1 1. Check the impedance between
Resistance 
the PV array output and PE,
The PV string is
and eliminate short circuits
short-circuited to PE.
and poor insulation points.
 The PV string is installed 2. Check that the SUN2000L PE
in a moist environment cable is correctly connected.
for a long time.
3. If you confirm that the
impedance is less than the
default value in a cloudy or
rainy environment, reset
Insulation resistance
protection.
2063 Overtemperature Major Cause ID = 1  Check the ventilation and
 The SUN2000L is ambient temperature at the
installed in a place with SUN2000L installation
poor ventilation. position.
 If the ventilation is poor or the
 The ambient temperature
exceeds the upper ambient temperature exceeds
threshold. the upper threshold, improve
the ventilation and heat
 The SUN2000L is not dissipation.
working properly.
 If both the ventilation and
ambient temperature meet
requirements, contact your
supplier or Huawei technical
support.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 79


SUN2000L-(2KTL-5KTL)
User Manual 7 System Maintenance

Alarm Alarm Name Alarm Possible Cause Suggestion


ID Severity

2064 Device Fault Major Cause ID = 1–12 Turn off the AC output switch and
An unrecoverable fault DC input switch, and then turn
occurs on a circuit inside the them on after 5 minutes. If the
SUN2000L. fault persists, contact your
supplier or Huawei technical
support.
2065 Upgrade Failed Major Cause ID = 1–4 1. Perform an upgrade again.
The upgrade does not end 2. If the upgrade fails several
normally. times, contact your supplier or
Huawei technical support.
3. Check that the DC power
supply is connected.
61440 Monitoring Unit Minor Cause ID = 1 Contact your supplier or Huawei
Faulty The communication module technical support to rectify the
is faulty. fault.

2067 Faulty Power Major Cause ID = 1 1. Check that the preset Smart
Collector Power Sensor model is the
The Smart Power Sensor
same as the actual model.
communication is
interrupted. 2. Check that the preset
communications parameters
for the Smart Power Sensor
are the same as the actual
configurations.
3. Check that the Smart Power
Sensor is powered on and the
RS485 communications cable
is correctly connected.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 80


SUN2000L-(2KTL-5KTL)
User Manual 7 System Maintenance

Alarm Alarm Name Alarm Possible Cause Suggestion


ID Severity

2068 Battery Minor Cause ID = 1 1. If the battery fault indicator is


Abnormal 
steady on or blinking, contact
The battery is faulty.
the battery supplier.
 The battery 2. Check that the battery
communication is enable/power/communications
interrupted. cable is correctly installed, and
 The battery switch trips that the communications
when the SUN2000L is parameters are the same as the
running. SUN2000L RS485
configurations.
3. Check that Auxiliary Power
switch on the battery is on.
4. Send a shutdown command on
the app. Turn off the AC
output switch, DC input
switch, and battery switch.
Then turn on the battery
switch, AC output switch, and
DC input switch in sequence
after 5 minutes.
5. If the alarm persists, contact
your supplier or Huawei
technical support.
2075 Peripheral Port Warning Cause ID = 1 1. Turn off the AC and DC
Short Circuit switches on the SUN2000L
The SUN2000L Alarm port
and disconnect the peripheral
is short-circuited when
from the Alarm port. Then
supplying 12 V power to
power on the SUN2000L
peripheral.
again and clear the alarm
manually. If the alarm persists,
contact your supplier or
Huawei technical support to
rectify the fault. If the alarm is
cleared, it indicates that the
port on the SUN2000L is
normal. Then check that the
pins in the power port on the
peripheral are not
short-circuited.
2. Replace the peripheral, and
then start a self-check to check
that the port functions
properly.

Contact your supplier or Huawei technical support if all failure analysis procedures listed above are
completed and the fault still exists.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 81


SUN2000L-(2KTL-5KTL)
User Manual 8 Handling the SUN2000L

8 Handling the SUN2000L

8.1 Removing the SUN2000L


Procedure
Step 1 Power off the system by following the instructions in 6.3 Powering Off the System.
Step 2 Disconnect all cables from the SUN2000L, including signal cables, DC input power cables,
battery cables, AC output power cables, and PE cables.
Step 3 Remove the WiFi antenna from the SUN2000L.
Step 4 Remove the SUN2000L from the mounting bracket.
Step 5 Remove the mounting bracket.
----End

8.2 Packing the SUN2000L


 If the original packaging is available, put the SUN2000L inside it and then seal it using
adhesive tape.
 If the original packaging is not available, put the SUN2000L inside a suitable cardboard
box and seal it properly.

8.3 Disposing of the SUN2000L


If the SUN2000L service life expires, dispose of it according to the local disposal rules for
electrical equipment and electronic component waste.

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 82


SUN2000L-(2KTL-5KTL)
User Manual 9 Technical Specifications

9 Technical Specifications

Efficiency
Item SUN2000L- SUN2000L- SUN2000L- SUN2000L- SUN2000L- SUN2000L-
2KTL 3KTL 3.68KTL 4KTL 4.6KTL 5KTL

Maximum 98.4% 98.5% 98.5% 98.6% 98.6% 98.6%


efficiency
European 97% 97.6% 97.8% 97.9% 98% 98%
weighted
efficiency

Input
Item SUN2000L- SUN2000L- SUN2000L- SUN2000L- SUN2000L- SUN2000L-
2KTL 3KTL 3.68KTL 4KTL 4.6KTL 5KTL

Maximum  600 V (No battery connects to the SUN2000L.)


input
 495 V (An LG-RESU battery connects to the SUN2000L.)
voltagea
Maximum 11 A
input current
(per MPPT)
Maximum 15 A
short-circuit
current (per
MPPT)
Maximum 0A
inverter
backfeed
current to the
PV array
Operating  90–500 V (No battery connects to the SUN2000L.)
voltage range  90–495 V (An LG-RESU battery connects to the SUN2000L.)

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 83


SUN2000L-(2KTL-5KTL)
User Manual 9 Technical Specifications

Item SUN2000L- SUN2000L- SUN2000L- SUN2000L- SUN2000L- SUN2000L-


2KTL 3KTL 3.68KTL 4KTL 4.6KTL 5KTL

Start voltage  120–600 V (No battery connects to the SUN2000L.)


range  120–495 V (An LG-RESU battery connects to the SUN2000L.)
MPPT  90–500 V (No battery connects to the SUN2000L.)
voltage range  90–425 V (An LG-RESU battery connects to the SUN2000L.)
Rated input 380 V
voltage
Number of 2
inputs
Number of 2
MPP trackers
Note a: Maximum input voltage includes the voltage of PV and battery inputs.

Output
Item SUN2000L- SUN2000L- SUN2000L- SUN2000L- SUN2000L- SUN2000L-
2KTL 3KTL 3.68KTL 4KTL 4.6KTL 5KTL

Rated output 2000 W 3000 W 3680 W 4000 W 4600 W 5000 W


powera
Maximum 2200 VA 3300 VA 3680 VA 4400 VA 5000 VA 5500 VA
apparent
powerb
Rated output 220 V/230 V/240 V
voltage
Adapted grid 50 Hz/60 Hz
frequency
Maximum 10 A 15 A 16 A 20 A 23 A 25 A
output
currentc
Power factor 0.8 leading... 0.8 lagging
Maximum ≤ 3%
total
harmonic
distortion
(rated power)

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 84


SUN2000L-(2KTL-5KTL)
User Manual 9 Technical Specifications

Item SUN2000L- SUN2000L- SUN2000L- SUN2000L- SUN2000L- SUN2000L-


2KTL 3KTL 3.68KTL 4KTL 4.6KTL 5KTL
 Note a: The maximum output power of the SUN2000L-5KTL is 4990 W if the Australian AS4777 grid code
is selected.
 Note b: The maximum apparent power of the SUN2000L-4.6KTL is 4600 VA if the Germany VDE-AR-N
4105 grid code is selected. The maximum apparent power of the SUN2000L-4.6KTL and SUN2000L-5KTL
is 4990 VA if the Australian AS4777 grid code is selected.
 Note c: The maximum output current of the SUN2000L-4.6KTL and SUN2000L-5KTL is 21.7 A if the
Australian AS4777 grid code is selected.

Protection
Item SUN2000L- SUN2000L- SUN2000L- SUN2000L- SUN2000L- SUN2000L-
2KTL 3KTL 3.68KTL 4KTL 4.6KTL 5KTL

Anti-islandin Supported
g protection
Input reverse Supported
polarity
protection
Output Supported
short-circuit
protection
RCMU Supported
AC surge Supported
protection
DC surge Supported
protection
Output Supported
overvoltage
protection
Insulation Supported
resistance
detection

Communication
Item SUN2000L- SUN2000L- SUN2000L- SUN2000L- SUN2000L- SUN2000L-
2KTL 3KTL 3.68KTL 4KTL 4.6KTL 5KTL

Display LED
WiFi Supported

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 85


SUN2000L-(2KTL-5KTL)
User Manual 9 Technical Specifications

Item SUN2000L- SUN2000L- SUN2000L- SUN2000L- SUN2000L- SUN2000L-


2KTL 3KTL 3.68KTL 4KTL 4.6KTL 5KTL

RS485 Supported

Common parameters
Item SUN2000L- SUN2000L- SUN2000L- SUN2000L- SUN2000L- SUN2000L-
2KTL 3KTL 3.68KTL 4KTL 4.6KTL 5KTL

Topology Transformerless
Ingress IP65
Protection
Rating
Cooling Natural cooling
mode
Dimensions 375 mm x 375 mm x 117 mm (excluding the mounting plate)/375 mm x 375 mm x 149.5 mm
(W x H x D) (including the mounting plate)/440 mm x 440mm x 231mm (including the package)
Weight Net weight: 11.6 kg (including the mounting plate)
Including the package: 13.8kg
Operating –30°C to +60°C (derated above +45°C)
temperature
Humidity 0%–100% RH
Operating 0–4000 m (derated above 2000 m)
altitude

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 86


SUN2000L-(2KTL-5KTL)
User Manual A Grid Codes

A Grid Codes

Grid codes are subject to change. The listed codes are for your reference only.

Table A-1 Grid codes (SUN2000L-2KTL/SUN2000L-3KTL)

No. Grid Code Description Grid Voltage Grid


Frequency

1 VDE-AR-N-4105 Germany 230 V 50 Hz


low-voltage power
grid
2 NB/T 32004 China Golden Sun 220 V 50 Hz
low-voltage power
grid
3 UTE C France mainland 230 V 50 Hz
15-712-1(A) power grid
4 UTE C France island 230 V 50 Hz
15-712-1(B) power grid (50 Hz)
5 UTE C France island 230 V 60 Hz
15-712-1(C) power grid (60 Hz)
6 G83-England England 230 V 230 V 50 Hz
power grid (I < 16
A)
7 G83-Scotland Scotland 240 V 240 V 50 Hz
power grid (I < 16
A)
8 CEI0-21 Italy power grid 230 V 50 Hz
9 EN50438-NL Netherlands power 230 V 50 Hz
grid
10 AS4777 Australia power 230 V 50 Hz
grid
11 IEC61727 IEC61727 230 V 50 Hz

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 87


SUN2000L-(2KTL-5KTL)
User Manual A Grid Codes

No. Grid Code Description Grid Voltage Grid


Frequency
low-voltage power
grid (50 Hz)
12 EN50438-TR Turkey low-voltage 230 V 50 Hz
power grid
13 IEC61727-60Hz IEC61727 230 V 60 Hz
low-voltage power
grid (60 Hz)
14 CLC/TS50549_IE Ireland power grid 230 V 50 Hz

Table A-2 Grid codes (SUN2000L-3.68KTL)

No. Grid Code Description Grid Voltage Grid


Frequency

1 VDE-AR-N-4105 Germany 230 V 50 Hz


low-voltage power
grid
2 UTE C France mainland 230 V 50 Hz
15-712-1(A) power grid
3 UTE C France island 230 V 50 Hz
15-712-1(B) power grid (50 Hz)
4 UTE C France island 230 V 60 Hz
15-712-1(C) power grid (60 Hz)
5 G83-England England 230 V 230 V 50 Hz
power grid (I < 16
A)
6 G83-Scotland Scotland 240 V 240 V 50 Hz
power grid (I < 16
A)
7 CEI0-21 Italy power grid 230 V 50 Hz
8 EN50438-NL Netherlands power 230 V 50 Hz
grid
9 AS4777 Australia power 230 V 50 Hz
grid
10 IEC61727 IEC61727 230 V 50 Hz
low-voltage power
grid (50 Hz)
11 EN50438-TR Turkey 230 V 50 Hz
low-voltage power
grid

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 88


SUN2000L-(2KTL-5KTL)
User Manual A Grid Codes

No. Grid Code Description Grid Voltage Grid


Frequency

12 IEC61727-60Hz IEC61727 230 V 60 Hz


low-voltage power
grid (60 Hz)
13 CLC/TS50549_IE Ireland power grid 230 V 50 Hz

Table A-3 Grid codes (SUN2000L-4KTL)

No. Grid Code Description Grid Voltage Grid


Frequency

1 VDE-AR-N-4105 Germany 230 V 50 Hz


low-voltage power
grid
2 NB/T 32004 China Golden Sun 220 V 50 Hz
low-voltage power
grid
3 UTE C France mainland 230 V 50 Hz
15-712-1(A) power grid
4 UTE C France island 230 V 50 Hz
15-712-1(B) power grid (50 Hz)
5 UTE C France island 230 V 60 Hz
15-712-1(C) power grid (60 Hz)
6 G59-England England 230 V 230 V 50 Hz
power grid (I > 16
A)
7 G59-Scotland Scotland 240 V 240 V 50 Hz
power grid (I > 16
A)
8 CEI0-21 Italy power grid 230 V 50 Hz
9 EN50438-NL Netherlands power 230 V 50 Hz
grid
10 AS4777 Australia power 230 V 50 Hz
grid
11 IEC61727 IEC61727 230 V 50 Hz
low-voltage power
grid (50 Hz)
12 EN50438-TR Turkey low-voltage 230 V 50 Hz
power grid
13 IEC61727-60Hz IEC61727 230 V 60 Hz
low-voltage power

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 89


SUN2000L-(2KTL-5KTL)
User Manual A Grid Codes

No. Grid Code Description Grid Voltage Grid


Frequency
grid (60 Hz)
14 CLC/TS50549_IE Ireland power grid 230 V 50 Hz

Table A-4 Grid codes (SUN2000L-4.6KTL)

No. Grid Code Description Grid Voltage Grid


Frequency

1 VDE-AR-N-4105 Germany 230 V 50 Hz


low-voltage power
grid
2 UTE C France mainland 230 V 50 Hz
15-712-1(A) power grid
3 UTE C France island 230 V 50 Hz
15-712-1(B) power grid (50 Hz)
4 UTE C France island 230 V 60 Hz
15-712-1(C) power grid (60 Hz)
5 G59-England England 230 V 230 V 50 Hz
power grid (I > 16
A)
6 G59-Scotland Scotland 240 V 240 V 50 Hz
power grid (I > 16
A)
7 CEI0-21 Italy power grid 230 V 50 Hz
8 EN50438-NL Netherlands power 230 V 50 Hz
grid
9 AS4777 Australia power 230 V 50 Hz
grid
10 IEC61727 IEC61727 230 V 50 Hz
low-voltage power
grid (50 Hz)
11 EN50438-TR Turkey 230 V 50 Hz
low-voltage power
grid
12 IEC61727-60Hz IEC61727 230 V 60 Hz
low-voltage power
grid (60 Hz)
13 CLC/TS50549_IE Ireland power grid 230 V 50 Hz

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 90


SUN2000L-(2KTL-5KTL)
User Manual A Grid Codes

Table A-5 Grid codes (SUN2000L-5KTL)

No. Grid Code Description Grid Voltage Grid


Frequency

1 UTE C France mainland 230 V 50 Hz


15-712-1(A) power grid
2 NB/T 32004 China Golden Sun 220 V 50 Hz
low-voltage power
grid
3 UTE C France mainland 230 V 50 Hz
15-712-1(A) power grid
4 UTE C France island 230 V 50 Hz
15-712-1(B) power grid (50 Hz)
5 UTE C France island 230 V 60 Hz
15-712-1(C) power grid (60 Hz)
6 G59-England England 230 V 230 V 50 Hz
power grid (I > 16
A)
7 G59-Scotland Scotland 240 V 240 V 50 Hz
power grid (I > 16
A)
8 CEI0-21 Italy power grid 230 V 50 Hz
9 EN50438-NL Netherlands power 230 V 50 Hz
grid
10 AS4777 Australia power 230 V 50 Hz
grid
11 IEC61727 IEC61727 230 V 50 Hz
low-voltage power
grid (50 Hz)
12 EN50438-TR Turkey low-voltage 230 V 50 Hz
power grid
13 IEC61727-60Hz IEC61727 230 V 60 Hz
low-voltage power
grid (60 Hz)
14 CLC/TS50549_IE Ireland power grid 230 V 50 Hz

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 91


SUN2000L-(2KTL-5KTL)
User Manual B Acronyms and Abbreviations

B Acronyms and Abbreviations

A
AC alternating current

D
DC direct current

I
ID identifier

L
LED light emitting diode
LVRT low voltage ride-through

M
MAC Media Access Control
MPPT maximum power point
tracking

P
PC personal computer
PE protective earthing
PV photovoltaic

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 92


SUN2000L-(2KTL-5KTL)
User Manual B Acronyms and Abbreviations

RCD residual current device


RCMU residual current monitoring
unit
RH relative humidity

S
SN serial number

T
THDi total distortion of the input
current waveform

W
WEEE waste electrical and
electronic equipment
WiFi Wireless Fidelity

Issue 05 (2019-06-06) Copyright © Huawei Technologies Co., Ltd. 93