The Model 515 BF03 is a batch/flow controller for mass frequency flowmeters that provides: 1) Dual stage control for preset batch quantities and flowrates using mass frequency inputs. 2) Easy access to batch and flowrate presets from the front panel as well as remote control via communications. 3) PI loop control of the process flow via a 4-20mA valve or pump controller with integral wind-up protection and other features.

Uploaded by

pcxhu1
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
20 views4 pages

515 BF03 Ap

The Model 515 BF03 is a batch/flow controller for mass frequency flowmeters that provides: 1) Dual stage control for preset batch quantities and flowrates using mass frequency inputs. 2) Easy access to batch and flowrate presets from the front panel as well as remote control via communications. 3) PI loop control of the process flow via a 4-20mA valve or pump controller with integral wind-up protection and other features.

Uploaded by

pcxhu1
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Model 515

Application BF03
Dual Stage
Batch/Flow Controller
for Mass Frequency Flowmeters

Overview Calculations
Features
The 515 BF03 application is a The total and flowrate are derived
• Tailored for mass frequency flow
batching flow controller for delivery of from accurately measured frequency
inputs
preset quantities at preset flowrates and the number of received pulses.
• Single or Dual stage control using a mass frequency input. Batch
• Preset or manual On-Off modes mass = pulses / k-factor
control can operate in preset or on-off
• Easy access to batch and flow modes, while flow control can be set mass flow = frequency / k-factor
rate presets to local (manual) or PI loop mode.
• No-flow, leakage and overflow Automatic overrun compensation
error detection This application provides the operator calculates the new valve closure point
• Remote RUN/STOP/RESET with clear local readout including to ensure correct delivery by
functions flowrate deviation and can be averaging the overrun amount from
• Allows for permissive with controlled via communications in the last three complete batches.
prompt more automated systems. There is
• Uses PI Loop Control quick access to commonly used The overrun compensation value is
preset values directly from the front valid for a new preset value provided
• Allows for non-linear correction
of flow input panel if access has been authorized. the stored overrun is less than 20% of
the new preset.
• Storage of 1000 transactions
The PI control of the process flow is
with time and date stamp
via a 4-20mA proportional valve or
• Selection of Detail or Basic main pump controller. It has integral wind-
menu to suit operator and
up protection, a deadband, output
application
hold and ramp time that can be
• Available protocols on programmed to reduce wear on
communication ports including
valves and actuators and provide for
Printers, Modbus RTU & TCP/IP
bumpless operation.

Analog Frequency Relay 1


Output 1 Input

Example
Batch/Flow
Configuration

Proportional Mass On-Off Flow


Control Device Flowmeter Valve

Accuracy • Quality • Performance


Displayed Information Terminal Designations
The front panel display shows the current values of the Terminal
Designation Comment
input variables and the results of the calculations. A list of Label
the variables for this application and their type (total or 1 FINP 1+ Frequency Input 1+ Mass Flow Input
rate) is shown at the end of this document. 3 SG - Signal ground
15 Vo + 8-24 volts DC output Overload protected

The instrument can be supplied with a real-time clock for 16 G - DC Ground


17 Vi + DC power input DC power in 12-28V
storage of up to 1000 transactions with time and date
18 SH E Shield terminal
stamps.
19 RS485 + RS485 (+) Optional RS485 port may
20 COM-2 - RS485 (-) be replaced by Ethernet
21 port port.
Communications 22
G RS485 ground
1+ Switch 1 Remote Run
23 2+ Switch 2 Remote Stop/Reset
There are two communication ports available as follows: 24 LOGIC 3+ Switch 3 Permissive Input
INPUTS CAL Switch – In field
25 4+ Switch 4
• COM-1 RS-232 port access protection

• COM-2 RS-485 port (optional) or Ethernet (optional)


26
27
C- Signal ground
+ Output ch 1 (+)
OUT1 Process control output
28 - Output ch 1 (-)
The ports are available for remote data reading, printouts 29 + Output ch 2 (+)
and for initial application loading of the instrument. OUT2
30 - Output ch 2 (-)
Term 31 - Common 1-4
31 RC Relay Common 1-2
Isolated Outputs on legacy option card
32 R1 Relay 1 Single Stage Control
33 R2 Relay 2 Dual Stage Control
The opto-isolated outputs can be configured to retransmit RELAYS
34 R3 Relay 3
any main menu variable or provide various error/control
35 R4 Relay 4
signals (flow error, pump control, end-of-batch, etc.). One Term 36 only available on
output is standard, a second output is available as an 36 RC Relay common 3-4
new style option card
option. E E Mains ground
AC AC power in 100-
N N Mains neutral
MAINS 240VAC
Relay Outputs A A Mains active
RS232 COM-1 port 9-pin serial port

The relay outputs 1 and 2 are used to control the flow of


product for each delivery. These contacts are normally
open and can be used to drive external relays, valves,
pump circuits etc. The advanced option provides another
two relays that can be used as fully programmable alarms
for any rate type variable.

Software Configuration
The instrument can be programmed to suit the particular
application needs and the flexible I/O can be assigned as
required. Program settings can be changed either via the
front panel (depending on assigned access levels) or via
the 500 Series Program Manager (500-PM software).
The instrument stores all set-up parameters, totals and
logged data in non-volatile memory with at least 30 years
retention.
Side View Rear Top View RS232
Connectors Port
Dimension Drawings 22 mm
145 mm
25 mm
138 mm

Part Number Front


74 mm

66 mm

Panel
515.XXXXXX-BF03
see Product Codes to select required
features Mounting Clip

Min. 189 mm
Default Application software:
515-BF03-000000
67 mm
70 mm
139 mm
147 mm
Panel Cut-out
Specifications Logic Inputs
Signal Type CMOS, TTL, open collector, reed switch
Overvoltage 30V maximum
Operating Environment
Temperature +5 °C to +40 °C (standard - no coating) Relay Output
-20 °C to +60 °C (with conformal coating)
-30 °C to +60 °C (ExD housing with heater) No. of Outputs 2 relays plus 2 optional relays
Humidity 0 to 95% non condensing (conformal coating) Voltage 250 volts AC, 30 volts DC maximum
5% to 85% non condensing (no coating) (solid state relays use AC only)
Power Supply 100-240 V AC (+/-10%) 50-60 Hz (+/-10%) or Current 3A maximum - mechanical relays
12-28 V DC 1.5A maximum - solid state relays
Consumption 10 W (max) Overvoltage category II
Protection Sealed to IP65 (Nema 4X) when panel mounted Communication Ports
Dimensions 147 mm (5.8") width Ports COM-1 RS-232 port
(panel option) 74 mm (2.9") height COM-2 RS-485 or Ethernet port (optional)
170 mm (6.6") depth (behind the panel) Baud Rate 2400 to 19200 baud
Parity Odd, even or none
Display
Stop Bits 1 or 2
Type Backlit LCD with 7-digit numeric display and
11-character alphanumeric display Data Bits 8
Digits 15.5 mm (0.6") high Protocols ASCII, Modbus RTU, Modbus TCP/IP (Ethernet
Port), Printer
Characters 6 mm (0.24") high
LCD Backup Last data visible for 15 min after power down Transducer Supply
Update Rate 0.3 second Voltage 8 to 24 volts DC, programmable
Current 70 mA @ 24 V, 120 mA @ 12 V maximum
Non-volatile Memory
Protection Power limited output
Retention > 30 years
Data Stored Setup, Totals and Logs Isolated Output
No. of Outputs 2 configurable outputs
Approvals Configuration Pulse/Digital or 4-20 mA output
Electrical & UKCA, CE, CSA compliance
Interference Pulse/Digital Output
Enclosure Ex d Enclosure - ATEX & IECEx available for Signal Type Open collector
hazardous area (CSA Pending).
Field Mount Enclosure - UKCA, CE, CSA safe Switching 200 mA, 30 volts DC maximum
area weather proof enclosure.
Other - RoHS compliant Saturation 0.8 volts maximum
Pulse Width Programmable: 10 , 20, 50, 100, 200 or 500ms
Real Time Clock (Optional)
4-20 mA Output
Battery Type 3 volts Lithium button cell
- For Issue 7 option card, type CR2450N Supply 9 to 30 volts DC external
manufactured by Renata only
- For conformal coated ‘C’ version, type BR2032 Resolution 0.05% full scale
manufactured by Panasonic only Accuracy 0.05% full scale (20C)
- For non-conformal coated versions, type 0.1% (full temperature range, typical)
BR2032 and CR2032 manufactured by
Panasonic or Sony
Battery Life 5 years (typical) Important: Specifications are subject to change without notice.

Frequency Input (General)


Range 0 to 10 kHz for Pulse input type
0 to 5 kHz for Coil & NPS input types
Overvoltage 30 V maximum
Update Time 0.3 sec
Cutoff frequency Programmable
Configuration Pulse, coil or NPS input
Non-linearity Up to 10 correction points

Pulse
Signal Type CMOS, TTL, open collector, reed switch
Threshold Signals switch below 1.3 & above 2 volts

Coil
Signal Type Turbine and sine wave
Sensitivity 15 mV minimum amplitude (typical)

NPS
Signal Type NPS sensor to Namur standard
Ordering Information
Product Codes

Model Supplementary Code Description


515 . - BF03

1 Panel mount enclosure


2/7 Field mount enclosure (NEMA 4X / IP66) (7 specifies heater included)
Enclosure
3/5 Explosion proof Ex d (IECEx/ATEX), metric glands (5 specifies heater included)
4/6 Explosion proof Ex d (CSA), NPT glands (6 specifies heater included)
4 logic inputs, 1 isolated output, 2 relays (only relay type 1 is available), RS232
0
(DB9) communication port
4 logic inputs, 2 isolated outputs, 4 relays, real-time clock data logging, RS232
Output Options 1
(DB9) and RS485 communication ports
4 logic inputs, 2 isolated outputs, 4 relays, real-time clock data logging, RS232
2
(DB9) & Ethernet communication ports
1 Electromechanical relays only

Relay Type 2 2 electromechanical relays (1-2) and 2 solid state relays (3-4)

3 Solid state relays only


Inputs for 12-28VDC and 100-240 VAC, 50-60Hz
U
Power Supply (Previous Models: A = 110/120 VAC, E = 220/240 VAC)
D Input for 12-28VDC power only
Standard option (now with backlight & LCD backup)
Display Panel Option S
(original Full option: F, with Infra-Red comms, no longer available)
Conformal coating - required for maximum environmental operating range.
C
Recommended to avoid damage from moisture and corrosion.
PCB Protection
None - suitable for IEC standard 654-1 Climatic Conditions up to Class B2
N
(Heated and/or cooled enclosed locations)
Application Pack Number BF03 Defines the application software to be loaded into the instrument

Example full product part number is 515.111USC-BF03 (this is the number used for placing orders).

Main Menu Variables


Main Menu Default Preferred Variable
Variables Units Units Type
Mass kg Total
Process Flowrate kg/min Rate
Process Control Output % Rate
Process Flowrate Deviation % Rate
Preset Quantity * --- ---
* These variables are logged and can be printed but are not shown
in main menu.

500 Series in BZC Ex d enclosure

www.contrec.co.uk
Contrec Ltd Contrec - USA, LLC Contrec Systems Pty Ltd
Riverside, Canal Road 916 Belcher Drive 5 Norfolk Avenue
Sowerby Bridge, West Yorkshire Pelham, Alabama Ringwood, Victoria 3134
HX6 2AY United Kingdom AL 35124 United States Melbourne Australia
Tel: +44 1422 829944 Tel: +1 (205) 685 3000 Tel: +61 413 505 114
Email: [email protected] Email: [email protected] Email: [email protected]

BF03 AP 09/21