0% found this document useful (0 votes)
260 views4 pages

HBM C16iC3-40T - 2020

This document provides information about digital load cells, including their special features, specifications, and cable assignment. Key features include a digital RS-485 signal, nominal loads ranging from 20 to 60 tons, IP68/IP69K protection, and legal-for-trade verification up to 10,000 divisions. Specifications include accuracy classes, minimum load cell intervals, sensitivity and temperature coefficients, interface and power details.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
260 views4 pages

HBM C16iC3-40T - 2020

This document provides information about digital load cells, including their special features, specifications, and cable assignment. Key features include a digital RS-485 signal, nominal loads ranging from 20 to 60 tons, IP68/IP69K protection, and legal-for-trade verification up to 10,000 divisions. Specifications include accuracy classes, minimum load cell intervals, sensitivity and temperature coefficients, interface and power details.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

C16i...

Data sheet
Digital load cells

Special features

− Digital signal
(RS−485 / 4-wire)
− Nominal (rated) loads: 20 t ... 60 t
− Self-restoring function
− Simple installation
− Rust-resistant materials,
laser-welded, IP68/IP69K
− Verifiable up to 3000 divisions,
test report as per OIML R60
− Legal for trade up to 10 000 d
(NTEP Class III LM)
− Meets EMC requirements in
accordance with EN 45 501 and
EN 55 011
− Integrated overvoltage protection

Cable assignment

TA (TX−) RS−485 / 4-wire BUS


(SC232/422B)

TB (TX+)
Converter

RA (RX−)
RB (RX+)
UB
GND
green

green
white

black

white

black
gray

gray
blue

blue
red

red
RS −232

RB (RX+)

RB (RX+)
RA (RX−)

RA (RX−)
TB (TX+)

TB (TX+)
TA (TX−)

TA (TX−)
GND

GND

PC
UB

UB

C16i... C16i...

B0988−5.0 en 1

d_c16i_d (B0989−3.3 de) 070606 Kb


Specifications
Type C16i D1 C16i C3
Nominal (rated) load (Emax) 20 t 30 t 40 t 60 t 20 t 30 t 40 t 60 t
Accuracy class per OIML R60 D1 (0.0330 %) C3 (0.0180 %)
Number of load cell verification intervals (nLC) 1000 3000 (10 000 NTEP III LM)
% 0.0100 0.0083
Minimum load cell verification interval (vmin) 0.0200
of Emax (0.006 NTEP III LM) (0.006 NTEP III LM)
5 10 10
Minimum load cell verification interval (emin)
[6 LC] 10 [6 LC] [4 LC]
per EN 45 501 kg − − − −
10 [10 LC] 20 20
[... LC = max. number of load cells]
[10 LC] [10 LC] [10 LC]
Nominal (rated) sensitivity (Cn) digit 1 000 000
Sensitivity tolerance % ±0.03
Temperature coefficient of sensitivity (TKC) 1) % of Cn ±0.0250 1) ±0.0080 1)
Temperature coefficient of zero signal (TK0) / 10 K ±0.0285 ±0.0140 ±0.0116
Relative reversibility error (dhy) 1) ±0.0330 1) ±0.0170 1)
Non-linearity (dlin) 1) ±0.0300 1) ±0.0180 1)
% of Cn
Creep upon loading (dcr) over 30 min. ±0.0330 ±0.0167
Minimum dead load output return (DR), 30 min. ±0.0330 ±0.0167 (±0.0150 NTEP III LM)
Reference excitation voltage (Uref) 12
V (DC)
Nominal (rated) supply voltage range (BU) 8.5 ... 15 2)
Rated current consumption mA 50 2)
Resolution Bits 20 (at 1 Hz)
Data rate 1 / sec 200 | 100 | 50 | 25 | 12 | 6 | 3 | 2 | 1
Filter mode 0 8 ... 0.05 (low-pass)
Hz
Filter mode 1 8 ... 3 (low-pass)
Asynchronous interface RS−485 / 4-wire (cable length up to 500 m)
Baudrate baud 1200 ... 115200
Bus nodes max. 32
Nominal ambient temperature range (BT) −10 ... +40
Operating temperature range (Btu) °C −20 ... +70
Storage temperature range (Btl) −50 ... +85
Limit load (EL) 150
Breaking load (Ed) % > 350
Relative perm. vibrational stress of Emax
70
(Fsrel) (oscillation width as per DIN 50100)
Nominal (rated) load (Emax) 20 t 30 t 40 t 60 t 20 t 30 t 40 t 60 t
Nominal (rated) displacement at Emax (snom),
mm 0.65 0.75 0.85 1.22 0.65 0.75 0.85 1.22
approx.
Weight (G) with cable, approx. kg 2.2 2.4 3.0 3.8 2.2 2.4 3.0 3.8
IP68 (test conditions 1 m water column/100 h)
Degree of protection per EN60529 (IEC529)
IP69K (water at high pressure, steam cleaner)
Material: Measuring body + housing Stainless steel
Cable entry Stainless steel
Seal Viton
Cable sheath Thermoplastic elastomer
1) The values for non-linearity (dlin), relative reversibility error (dhy) and temperature coefficient of sensitivity (TCS) are recommended values.
The sum of these values is within the cumulative error limit for pLC = 0.8 according to OIML R60.
2) Refer to table for power supply in the mounting instructions!

Options for C16i...


S Cable length 20 m (Emax = 20 t + 30 t)
S Cable length 40 m (Emax = 20 t ... 60 t)
S Cable with metal mesh, 20 m (Emax = 20 t ... 60 t)

HBM 2 B0988−5.0 en

d_c16i_d (B0989−3.3 de) 070606 Kb


Dimensions and mounting parts (in mm; 1 mm = 0.03937 inches)
Built-in variant 1: Built-in variant 2:
C16 ... + C16/ZOU44A (max. load per load cell = 40 t) C16... + EPO3/50 t + C16/EPU44A
∅147
∅120
4 x M16 ∅18 ∅89 M10
∅85
∅64
2 x M8 M10
∅11

20

R
R

 ∅44
∅44

A
B
B
A

C
 ∅76.1

C

∅76.1 

EEK4
EEK4

Fastening bolts shown


rotated by 90°
View from above

3 x M16
 C16/ZOU44A
 EPO3/50 t
 C16/EPU44A
 Cable length (standard):
S 20 t + 30 t = 12 m;
120°
40 t + 60 t = 20 m
a
 Dowel pin ∅10 x 30 (rotation stop),
Sealing sleeve and hose clamp
included in load cell scope of supply

120°

Thrust pieces FR 4)
Built-in variant 1

Emax R 2) 3) (% of applied load)


C16... top + bottom A B C amax Smax
ball
(1 set = 2 pieces) at Smax at S = 1 mm
20 t 200 150 123 130 5° 13 6.4 0.49
30 t 200 150 123 160 5° 13 9.9 0.76
C16/ZOU44A 1)
40 t 200 150 123 180 5° 13 12.2 0.94
60 t 260 210 157 220 3° 11 5.7 0.52

FR 4)
Built-in variant 2

Emax Thrust pieces R


A B C amax 2) Smax 3) (% of applied load)
C16... ball
top bottom at Smax at S = 1 mm
20 t 229 150 123 130 5° 13 6.4 0.49
30 t 229 150 123 160 5° 13 9.9 0.76
EPO3/50 t C16/EPU44A
40 t 229 150 123 180 5° 13 12.2 0.94
60 t 289 210 157 220 3° 11 5.7 0.52
1) Max. loading: 40 t 3) Max. permissible lateral displacement of load application
2) Max. perm. misalignment 4) Restoring force

B0988−5.0 en 3 HBM

d_c16i_d (B0989−3.3 de) 070606 Kb


Accessories (to be ordered separately)

Thrust pieces
Built-in variant 1:
S C16/ZOU44A Thrust pieces (stainless) for top and bottom (1 set = 2 pieces), can be used with C16.../≤60 t
up to a max. load per load cell of 40 t, incl. 3 eccentric discs
Built-in variant 2:
S EPO3/50t Thrust piece for top, incl. clamping ring
S C16/EPU44A Thrust piece for bottom, incl. 3 eccentric discs

Evaluation electronics
S DIS2116 (see separate data sheet)

Serial converter
S Interface converter SC232/422B (see separate data sheet)

1)
• Conversion of RS-232 into 4-wire RS-422/485
or into 2-wire RS-485 (switchable)
• Electrical isolation
• High EMC security (metal housing)
• Operating voltage range 8 ... 30 V DC
• Incl. power supply unit 1)
and PC connection cable

1) Note:
The power supply unit delivers 15 V DC / 530 mA and is therefore suitable for supplying voltage for up to 8x C16i.
Please refer to the table for power supply in the load cell mounting instructions!

Subject to modifications. Hottinger Baldwin Messtechnik GmbH


All product descriptions are for general information only. They
are not to be understood as a guarantee of quality or durability.
Im Tiefen See 45 ⋅ 64293 Darmstadt ⋅ Germany
Tel. +49 6151 803-0 ⋅ Fax: +49 6151 803-9100
E-mail: [email protected] ⋅ www.hbm.com
B0988−5.0 en

measure and predict with confidence

d_c16i_d (B0989−3.3 de) 070606 Kb

You might also like