Ideal Insturment for Corrective
Maintenance
Portable Load Manager
ALM 31
www.atandra.in
1
SALIENT FEATURES– ALM 31
Followed IEC 61000-4-30 for accurate RMS measurements
• Superior Display with advanced TFT technology
• 256 samples/cycle, 12.8 kHz frequency
• 2GB Memory to measure and record all parameters
• Direct keys to access all parameters
• CAT IV 600V, Highest Safety standards
• USB port for downloading
CAT IV
IP 53 IK 08
600V
USB
www.atandra.in
2
SALIENT FEATURES – ALM 31
• Choice to select any parameter for recording
• Field programmable CT & PT ratio in instrument,
suitable for HT secondary measurements
• External power adaptor 85-265V for increased
reliability
• High Electrical safety standards with CAT IV 600V,
better protection IP53 /IK08
• Long Battery back-up
• 13 hours in operation
• 40 hours in logger mode
www.atandra.in
3
MEASUREMENTS SCREENSHOTS
V & A DC Component,
Voltage, Current, Fr, THDf , Voltage, Current Min/Max, Peak
Distortion factor CF, Flicker Pst
THDr, CF
Phasor Diagram, V&A Unbalance DPF, PF, kW, kVA & kVAr Energy Counter
www.atandra.in
4
ALM31
ALM 31FEATURES
FEATUTES
These features help you in your daily audits
All measurements are direct values for Immediate action
like kVAr, K-Factor, FHL, Flicker & Harmonic
measurements
All key functions can be reached with one touch, You don’t
require special training to operate the instrument
User can define start & Stop time to log the data and can
select only the required parameters including Harmonics.
Allows you to record few Hours to Days and 100 files can be
stored
Free License for Lifetime Dataview Software
A PQ analyser need a powerful software to analyse the
recorded data and prepare user friendly & editable reports
•With One touch you can export complete data to Excel or
PDF
•Default report template are available with standard
formats , user can create own templates and export the
reports
www.atandra.in
5
MULTI-TASKING
You can do all the following simultaneously
(Where most of the equipments do not have this feature)
Harmonic measurements: user can log
V, U, I, VA up t 50th harmonic order
View waveforms & data – realtime
time measurements
Log data – at user selected time interval
for any selected parameters
Scope Mode: See the waveforms and
take corrective action
Benefit for you:
No need to stop one activity to
do another; saves lot of time
and avoids multiple studies and
analysis
www.atandra.in
6
MEASUREMENT TECHNOLOGY
Accurate on all load conditions
True RMS measurements with 12.8 kHZ sampling frequency continuously
on all Voltage & Current channels
Benefits for you :
• Accurate on non-linear loads like VFDs, Rectifiers, UPS etc..
• Accurate on low PF conditions (no load on motors, transformers)
or on lead PF conditions (can measure kVAR & kW directly on
Capacitor Banks)
• Accurate on low current measurements
• Accurate on Dynamic load conditions like welding machine, high
speed printing machine, packing machines etc.
IEC 61000-4-30 followed For accurate RMS Measurement
www.atandra.in
7
SALIENT FEATURES – ALM 31
Technical Support & Training
•An adequate training will be provided with expert members and free
Tele and Email support
•An experience technical team to support on your application and
educate on new standard and methods
•Calibration check and Error adjustment facilities available with us no
need o instruments abroad for calibration and repairs (where most of
the equipment's are imported and have to send for repairs & Calibration
to OEMS)
In-house Calibration tools and Service centre
www.atandra.in
8
WIDE RANGE OF CURRENT CLAMPS
ALM 3x new series automatically recognizes the CTs when connected to the instrument. Independent
current channels allows user to connect different models of CTs at the same time to measure different
current ranges or range of currents.
Select CTs as per your need
• 10 clamp choices for different needs
• 5mA to 6500A; 28mm ID to 450mm ID
• AC/DC clamps for DC load applications NEW
• Special CT for measuring low DC current accurately
• Adapter for measuring secondary current of Panel CTs
NEW
www.atandra.in
9
HIGH ELECTRICAL SAFETY STANDARDS
Measure up to 1000V Ph-N
Complies with CAT IV 600V, CAT III 1000V as per IEC 61010-1 standards
Benefit for you:
Momentary high-voltage transients or spikes can travel through instruments at any time
without warning. Motors, capacitors, lightning, and power conversion equipment, such as
variable speed drives, are all possible sources of spikes.
Analysers designed for CAT IV standards provide users with higher degree of
protection from high voltage transient spikes compared to CAT III, CAT II, or CAT I designs.
www.atandra.in
10
FLEXIBLE RECORDING
Record what you want; save memory & time
Offers 4 user-configurable recording profiles to record different sets
of parameters for different applications; no need to fill your memory
with unwanted data
Set start and stop time for data logging; each record can be saved as a
separate data file; 100 data files can be stored in the instrument
Benefits for you:
• Preconfigured profiles help save memory and time; you can
setup and start recording in seconds.
• Record data only for desired duration using Start & Stop record
feature saving memory space.
• Record different files with different names for easy
identification.
Models Parameters Memory
ALM 31 All 4.95 Hours (Trend recording = 1 second)
All 13 days (Trend recording = 1 Minute)
All 61 days (Trend recording = 5 Minute)
www.atandra.in
11
DISTORTED kVAr MEASUREMENT
Now it’s possible to quantify the power generated by the P
harmonics. This power value is better known as Distorting
Power (D) and it is linked to the distorting amperes. The S1 Q
unit is distorting Volt-Ampere (VAd); This distortion power
has an immediate effect on the waveform and on the THD S
of the current.
D
Power factor correction equipment will not be of any use
because it acts only on the displacement power factor.
Correcting reactive power generated by the harmonics will
become more dangerous for power factor correction
equipment. To reduce the current harmonics (and therefore
the distorting amperes), you must install filtering
equipment.
www.atandra.in
12
OTHER FEATURES
Display Night Mode
Power Supply
Advantages:
90 Vac to 264 Vac
Inverted colors. Better
External Adapter
comfort reading during
dark light.
Security Slot Velcro Cable Ties
for CT Cables
Theft-prevention device. It
is used to secure the •Reusable
device with padlock. Ideal •Long enough
for engineers & auditors •Easy to use
on the move.
www.atandra.in
13
BETTER PROTECTION
Ingress Protection IP53
5 – Protection against solid objects 3 – Protection against liquids
protected against dust – limited protected against sprays
ingress permitted (no harmful up to 60° from the vertical
deposit)
Better Mechanical Protection IK08
impact 5 Joule (1.7 kg out of 29.5 cm)
www.atandra.in
14
Atandra Energy Private Limited
No-5 Kumaran Street, Pazhavanthangal, Chennai – 600114
Tel: 044-42780600/0700 www.atandra.in
www.atandra.in
15