LAUDA Proline Ats
LAUDA Proline Ats
Proline
Application examples
• Temperature control for
chemical synthesis
• Tests on electronic components
at different temperatures
• Temperature control of
measuring structures in
process technology
• Heating and cooling of glass Intuitive operation, ultra high and low temperatures
reactors
Proline Kryomats
Application examples
LAUDA Proline thermostats are our solution control unit for enhanced ease of operation.
• Constant temperatures in the
for high performance and reliable temperature Master version devices can be retrofitted with
notch bending test and drop
test regulation. With their broad temperature range the Command remote control, which are simply
• Changing temperatures when
determining the pour point,
they fulfill high requirements. LAUDA Proline
thermostats are available in two versions: in
connected to the control head. The thermostat
automatically recognises and controls all newly
Brookfield test of lubricants the basic version with the Master control head, installed moduls.
and test of slide bearings and as a Command version with a removable
Your advantages at a glance
• Two insert ports can be combined with • High level of flexibility for the user
five different interface modules allowing for broad range of system
integration
• Pump connections on the side and rear • Flexible connection of external appli-
cations from different sides
Proline
Master control head
• Easy-to-read green LED display
The Proline Master devices are designed with high thermostating accuracy
and reliability for all applications from -90 up to 300 °C where operating • Convenient setting of set-temperature and
Varioflex pump via three operation buttons
parameters are not changed or modified frequently. They have all the basic
features and safety functions required for professional thermostating during • Indicator lights for heating, cooling, external
continuous use. A modular structure and bus technology have created an control and alarm
instrument capable of extending its function and performance as the appli-
cation requires.
• Resolution of indication 0.01 °C, setting reso-
lution selectable 0.1 or 0.01 °C
• Selectable operating temperature range and
additional button for overtemperature protection
setting
• External temperature control via Pt100
• Optical and audible alarm function
• Simple temperature probe calibration
• Integrated mains network safety device
• Start mode control (automatic or manual)
• Two slots for interface modules
• LAUDA Wintherm Plus control software via
RS 232/485 interface (optional)
Easy replacement of interface modules Alarm message for malfunction Upgradable to Command version
Proline
Command control head
Basic equipment as Proline Master, plus:
The Command control heads are the top models of the LAUDA Proline.
The highly-efficient programer fulfills all the requirements of complex • 10-key console for setpoint adjustment of
temperature
thermostating processes – with real-time function. It offers the utmost in
user-friendliness and optimum functionality, e.g. for an industrial testing • Programer with real-time clock, 150 tempera-
lab. The simple menu-driven operation and the easy editing of test pro- ture/time segments, for use in up to 5 programs,
grams allow for quickly changing thermostating tasks. The Command editable segments with loop and tolerance band
remote control is removable and can easily be used with cable up to 50 m. function
Comprehensive basic equipment as with the Proline Master range. • High resolution, back-lit, graphic LCD display
with various display possibilities
• Detachable Command remote control for use
with cable up to 50 m
An opto-decoupled RS 232/485 interface is Drop-down menus make settings easy. Graphic display of temperature values
integrated as standard Available in four languages.
LAUDA Proline
6 1 Step 1
5 2 Step 2
The heating thermostats of the LAUDA Proline with Master control head do 7 8
0.4 4 3 Step 3
not only convince because of their compact construction. The high heater 3 4 Step 4
power of 3.5 kW (230 V), two interfaces for various modules, a cooling 2 5 Step 5
coil fitted as a standard feature, and an integrated external control – these 1 6 Step 6
0 7 Step 7
features make them particularly useful for users who require flexible ther- 8 Step 8
mostating operations while only rarely needing to adjust the settings.
-0.4
0 10 20 L/min
Sog Flow
Temperature range
30...300 °C
Included accessories
Bath cover · 2 nipples and 4 closing plugs for
pump connections · 2 nipples for cooling coil
Additional accessories
Constant level device (for P 8) · automatic filling device ·
through-flow cooler · reverse flow protection ·
tubes · solenoid valve for cooling water control · high-
temperature cooler (water) · Interface modules:
analog, RS 232/485, contact, Profibus module
Heating thermostat P 18
Technical features P5 P8 P 12 P 18
Working temperature range* °C 35...300 35...300 30...300 30...300
Temperature stability ±K 0.01 0.01 0.01 0.01
Heater power 115 V/208-220 V kW 1.8/3.5 1.8/3.5 1.8/3.5 1.8/3.5
Pump pressure max. bar 0.7 0.7 1.1** 0.7
Pump suction max. bar 0.4 0.4 - 0.4
Pump flow (pressure) max. L/min 25 25 32** 25
Pump flow (suction) max. L/min 23 23 - 23
Bath volume L 3.5...5.5 5.5...8 6.5...13.5 12.5...19
Bath opening/Bath depth mm 150x50/200 150x150/200 150x150/320 300x200/200
Cat. No. 115 V; 60 Hz LCB 4708 LCB 4710 LCB 4716*** LCB 4712
Cat. No. 208-220 V; 60 Hz LCB 8708 LCB 8710 LCB 8716*** LCB 8712
* Working temperature range with water cooling 20...300 °C ** Pressure pump only, pump characteristics see page 42 *** Instead of pressure and suction pump equipped with increased output
Proline Heating curves Heat transfer liquid: Ultra 300, bath closed
1 P 26
250 2 P 40
The LAUDA Proline P 26, P 40 and P 50 heating thermostats are
3 P 50
distinguished by particularly large-volume baths. All the below models 200
are equipped with a Varioflex pump and cover the temperature range from
30 up to 300 °C. These stainless steel baths are ideally suited to direct 150
Included accessories
Bath cover (only P 26) · 2 nipples and 4 closing
plugs for pump connections · 2 nipples for cooling coil
Additional accessories
Bath cover · automatic filling device · through-flow cooler ·
reverse flow protection · tubes · solenoid valve for cooling
water control · high-temperature cooler (water) ·
rising platform · Interface modules: analog, RS 232/485,
contact, Profibus module
Heating thermostat P 50
Technical features P 26 P 40 P 50
Working temperature range* °C 30...300 30...300** 30...300**
Temperature stability ±K 0.01 0.01 0.01
Heater power 115 V/208-220 V kW 1.8/3.5 –/3.5 –/3.5
Pump pressure max. bar 0.7 0.7 0.7
Pump suction max. bar 0.4 0.4 0.4
Pump flow (pressure) max. L/min 25 25 25
Pump flow (suction) max. L/min 23 23 23
Bath volume L 18...27 30…37 35...53
Bath opening/Bath depth mm 300x350/200 250x270/450 300x750/200
Cat. No. 115 V; 60 Hz LCB 4714 – –
Cat. No. 208-220 V; 60 Hz LCB 8714 LCB 8728 LCB 8730
* Working temperature range with water cooling 20...300 °C ** Max. temperature only achieved with closed bath cover
LAUDA Proline
Proline Heating curves Heat transfer liquid: Ultra 300, bath closed
Bath temperature
Heating thermostats with Command °C
1 2 3 4
1 P 5/P 5 C
250 2 P 8/P 8 C
The Proline heating thermostats with Command control head (C) impress
3 P 12/P 12 C
through an expanded scope of functions. Alongside a graphic LCD display, 200 4 P 18/P 18 C
which enables current values to be displayed up to 0.001 ºC resolution,
an easily editable and convenient programmer with storage possibilities is 150
0 20 40 60 min
Heating time
Temperature range
30...300 °C
Included accessories
Bath cover · 2 nipples and 4 closing plugs for pump
connections · 2 nipples for cooling coil
Additional accessories
Constant level device (for P 8 C) · automatic filling
device · through-flow cooler · reverse flow protection ·
tubes · solenoid valve for cooling water control · high-
temperature cooler (water) · Interface modules:
analog, RS 232/485, contact, Profibus module
Heating thermostat P 18 C
1 P 26 C
250
In order to enhance ease of use even further, P 26 C, P 40 C and P 50 C 2 P 40 C
3 P 50 C
heating thermostats with large baths are also available with the Command 200
control head which allows complex thermostating functions, particularly
those with internal thermostating processes, to be easily mastered with 150
the aid of an intuitive operation guidance system and the ability to edit
100
programs rapidly.
50
A circulation chamber on the P 40 and P 50 ensures good mixing in the
bath and thus guarantees good temperature homogeneity, despite the
0 40 80 120 140 160 180 min
large bath vessel. Heating time
Temperature range
30...300 °C
Included accessories
Bath cover (only P 26 C) · 2 nipples and 4 closing plugs
for pump connections · 2 nipples for cooling coil
Additional accessories
Automatic filling device · bath cover · through-flow
cooler · reverse flow protection · tubes · solenoid
valve for cooling water control · high-temperature cooler
(water) · rising platform · Interface modules: analog,
RS 232/485, contact, Profibus module
Heating thermostat P 40 C
Technical features P 26 C P 40 C P 50 C
Working temperature range* °C 30...300 30...300** 30...300**
Temperature stability ±K 0.01 0.01 0.01
Heater power 115 V/208-220 V kW 1.8/3.5 –/3.5 –/3.5
Pump pressure max. bar 0.7 0.7 0.7
Pump suction max. bar 0.4 0.4 0.4
Pump flow (pressure) max. L/min 25 25 25
Pump flow (suction) max. L/min 23 23 23
Bath volume L 18...27 30…37 35...53
Bath opening/Bath depth mm 300x350/200 250x270/450 300x750/200
Cat. No. 115 V; 60 Hz LCB 4715 – –
Cat. No. 208-220 V; 60 Hz LCB 8715 LCB 8729 LCB 8731
* Working temperature range with water cooling 20...300 °C ** Max. temperature achieved only with closed bath cover
LAUDA Proline
Pump characteristics Heat transfer liquid: Water
Pressure
Proline bar
0.8
8
Clear-view thermostats 7
6
0.6 5
LAUDA Proline clear-view thermostats for the direct observation of the 1 Step 1
4 2 Step 2
samples: the PVL models come equipped with five layers of insulating
3 Step 3
glass and are suitable for low temperatures down to -60 °C. This ma- 0.4
3 4 Step 4
kes them ideal for the use with the fully-automatic LAUDA PVS viscosity 5 Step 5
6 Step 6
measuring system. The two-chamber principle in the measuring area en- 2
0.2 7 Step 7
sures a constant level, irrespective of the loading and the temperature. 1 8 Step 8
The connection of a through-flow cooler or Proline RP 890 enables low
temperature measurements down to -40 °C/-60 °C. 0 10 20 L/min
Flow
Heating curves Heat transfer liquid: Therm 240, bath closed
Bath temperature
°C
1 2 3
200
50
0 20 40 60 min
Heating time
Temperature range
30...230 °C
LAUDA PVS 1/4 viscosity measuring system with PV 24 clear-view thermostat Included accessories
– Stands not included in scope of delivery – 2 nipples and 4 closing plugs for pump connections ·
2 nipples for cooling coil
Additional accessories
All technical data on page 102 and following
Window heating system – PVL 15 (C), PVL 24 (C) only ·
Other power supply variants on page 113
solenoid valve for cooling water · atherman illuminator
Technical features PV 15/PV 15 C PV 24/PV 24 C PV 36/PV 36 C PVL 15/PVL 15 C PVL 24/PVL 24 C
Working temperature range °C 30...230 30...230 30...230 30...100 30...100
Operating temperature range °C 0*...230 0*...230 0*...230 -60**...100 -60**...100
Temperature stability ±K 0.01 0.01 0.01 0.01 0.01
Heater power 115 V/208-220 V kW 1.8/– –/3.5 –/3.5 1.8/– 1.8/–
Pump pressure max. bar 0.8 0.8 0.8 0.8 0.8
Pump suction max. bar – – – – –
Pump flow (pressure) max. L/min 25 25 25 25 25
Pump flow (suction) max. L/min – – – – –
Bath volume L 11…15 19…24 28…36 11…15 19…24
Bath opening/Bath depth mm 230x135/320 405x135/320 585x135/320 230x135/320 405x135/320
Size of glass panel mm 149x230 326x230 506x230 149x230 326x230
Cat. No. Master 115 V; 60 Hz LCD 4276 – – LCD 4282 LCD 4284
Cat. No. Master 208-220 V; 60 Hz – LCD 8278 LCD 8280 – –
Cat. No. Command 115 V; 60 Hz LCD 4277 – – LCD 4283 LCD 4285
Cat. No. Command 208-220 V; 60 Hz – LCD 8279 LCD 8281 – –
* Only achievable with LAUDA through-flow cooler ** Only achievable with LAUDA Proline RP 890
Pump characteristics for PB and PBC,
Heat transfer liquid: Water
Proline Pressure
bar
Bridge thermostats
0.8
6
5
4 7 8
LAUDA Proline bridge thermostats are available in two versions with 0.4
3 1 Step 1
different pump models and immersion depths. The PB models have a 2 2 Step 2
pressure/suction pump and require a bath depth of 200 mm, while the 1 3 Step 3
PBD models have a more powerful pressure pump (D) and require a bath 0 4 Step 4
with a depth of 320 mm. In addition, both series of models differ in the 5 Step 5
6 Step 6
selected control head: Master or Command (C). Through variably extenda- 7 Step 7
ble telescopic rods, all models can be attached without problem to baths -0.4 8 Step 8
with a width from 310 mm up to 550 mm.
0 10 20 L/min
Suction Flow
1.2
1 Step 1
6 2 Step 2
1
3 Step 3
5
4 Step 4
0.8
4 5 Step 5
6 Step 6
0.6 3 7 8 7 Step 7
8 Step 8
0.4 2
0.2 1
0 10 20 30 L/min
Flow
Temperature range
Bridge thermostat PBD C 30...300 °C
– Bath not included in scope of delivery – Included accessories
2 nipples and 4 closing plugs for pump connections ·
telescopic rods
Additional accessories
Automatic filling device · water bath · Interface modules:
All technical data on page 102 and following analog, RS 232/485, contact, Profibus module
Other power supply variants on page 113
Proline ❄
Cooling curves Heat transfer liquid: Ethanol, bath closed
Bath temperature
Cooling thermostats with Master °C
1 RP 845
The Proline RP 845, RP 855, RP 870 and RP 890 cooling thermostats 0 2 RP 3530
3 RP 1840
stand out above all for their compact dimensions and small footprint. With
-20 4 RP 1845
a cooling capacity of 1.6 kW at 20 °C, the RP 855 has a particularly high- 1
5 RP 855
2
performance design. The RP 890 low-temperature device enables you to -40
6 RP 870
7 RP 1290
reach temperatures down to -90 °C. The standard integrated electrical- 3
4 8 RP 890
heated bath cover set prevents icing as a result of condensation and hu- -60
5
midity on all Proline cooling thermostats with a temperature range down 6
-80 7
to -90 °C. 8
0 40 80 120 min
Cooling time
Temperature range
-90...200 °C
Included accessories
Bath cover · 2 nipples and 4 closing plugs for pump
connections · electrical-heated bath cover set for RP 890
Additional accessories
Constant level device for RP 845 and RP 855 · reverse
flow protection · automatic filling device · tubes ·
electrical-heated bath cover set for RP 855 and RP 870
(only ex works) · Interface modules: analog, RS 232/485,
contact, Profibus module · set of castors (RP 855 to RP 890)
All types
(except RP 870)
Cooling thermostat RP 845
1 RP 855
The Proline RP 1290, RP 1840, RP 1845 and RP 3530 cooling thermostats 150
RP 845
RP 870
differ in terms of bath volume, achievable cooling capacity, and working
RP 890
temperature range. With bath capacities up to 35 liters, the RP 3530 2 RP 1290
provides a particularly large bath volume and the RP 1845 provides a 100 3 RP 1840
RP 1845
particularly high cooling capacity of 1.6 kW. To prevent icing the RP 1290
4 RP 3530
is equipped with an electrical-heated bath cover set.
50
0 20 40 60 min
Heating time
Temperature range
-88...200 °C
Included accessories
Bath cover · 2 nipples and 4 closing plugs for pump
connections · electrical-heated bath cover set for RP 1290
Additional accessories
Reverse flow protection · automatic filling device · tubes ·
Interface modules: analog, RS 232/485, contact, Profibus
module · set of castors (RP 1290 to RP 1845)
All types
Cooling thermostat RP 1845
1 RP 845 C
The SmartCool system – an energy-saving, digital cooling management 0 2 RP 3530 C
3 RP 1840 C
system – ensures that every temperature is run with the correct cooling ca-
-20 4 RP 1845 C
pacity. It increases or reduces the cooling according to application require- 1
5 RP 855 C
2
ments. The advantages are particularly effective for programmer operation -40
6 RP 870 C
7 RP 1290 C
and temperature ramping. 3
8 RP 890 C
4
-60
5
The Proline cooling thermostats with the Command control head (C) have 6
-80 7
a convincing extended range of functions. At 20 °C, RP 855 C has a par- 8
ticularly high cooling capacity of 1.6 kW. RP 890 C and RP 1290 C are
0 40 80 120 min
designed for especially low temperatures. They differ in terms of bath Cooling time
volume and have an electrical-heated bath cover set as a standard feature.
Temperature range
-90...200 °C
Included accessories
Bath cover · 2 nipples and 4 closing plugs for pump
connections · electrical-heated bath cover set for RP 890 C
Additional accessories
Constant level device for RP 845 C und RP 855 C · reverse flow
protection · automatic filling device · tubes · electrical-heated
bath cover set for RP 855 C and RP 870 C (only ex works) ·
Interface modules: analog, RS 232/485, contact, Profibus
module · set of castors (RP 855 C to RP 890 C)
All types
(except RP 870 C)
Cooling thermostat RP 845 C
1 RP 855 C
Thanks to their various capacity ranges and filling volumes, the Proline 150
RP 845 C
RP 870 C
cooling thermostats which make up the Command range skilfully adapt
RP 890 C
to your requirements. The RP 1845 C works at a temperature range bet- 2 RP 1290 C
ween -50 and 200 °C and, at 20 °C, has a cooling capacity of 1.6 kW. The 100 3 RP 1840 C
RP 1845 C
RP 3530 C has a particularly large bath for internal sample thermostating.
4 RP 3530 C
The RP 1290 C comes with an integrated electrical-heated bath cover set
as standard. 50
0 20 40 60 min
Heating time
Temperature range
-88...200 °C
Included accessories
Bath cover · 2 nipples and 4 closing plugs for pump
connections · electrical-heated bath cover set for RP 1290 C
Additional accessories
Reverse flow protection · automatic filling device · tubes ·
Interface modules: analog, RS 232/485, contact, Profibus
module · set of castors (RP 1290 C to RP 1845 C)
All types
Cooling thermostat RP 1840 C
Application examples
Constant temperatures
• Notch bending test
• Drop test
Changing temperatures
• Determination of pour point
• Brookfield test of lubricants
• Test of slide bearings
The Proline Kryomats are floor-standing, low temperature thermo- circulation adjustable from performance level five to eight. To prevent
stats suitable for a wide variety of applications. They never fail to moisture in the atmosphere from condensing at low temperatures,
impress through their compact design and high cooling capacities, bath bridge and bath edge heating are integrated into the design.
especially at low temperatures. All Proline Kryomats are fitted with Proline Kryomats stand out for having the latest technologies and an
the Command remote control for easy and user-friendly operation. excellent price-performance ratio.
The units are equipped with a pressure pump optimized for internal
Your advantages at a glance
The Proline Kryomats Your benefits
advantages
• Integrated bath edge and bath bridge • Avoids condensation and ice build-up
heating
• Use of innovative cooling technology • High cooling capacity and low operating
temperatures with very small footprint
• Spacious baths with large bath openings • Accomodates various sample shapes
and sizes with efficient flow
• Thread sleeves as standard on the edge • Allow for the fixing of testing equipment
of the bath without further conversion measures
Proline Kryomats ❄ Cooling curves Heat transfer liquid: Ethanol, bath closed
The air-cooled Proline Kryomats have a working temperature range from 0 1 RP 3050 C
2 RP 4050 C
-50 and -90 up to 200 °C. The models are available with bath volumes
-20 3 RP 3090 C
of 30 and 40 liters. The Proline SmartCool system, with its energy- 4 RP 4090 C
saving digital cooling management, ensures that the cooling output is run in -40
accordance with the application needs. That saves up to 75 percent of en- 2
ergy compared to standard cooling methods. Two different booster pumps -60
1
3 4
are available as options (ex works) especially for external applications that
-80
require a considerable increase in volume flow/discharge pressure.
-100
0 10 20 30 40 50 60 70 80 90 100 min
Cooling time
Temperature range
-90...200 °C
Included accessories
Bath cover · 4 closing plugs for pump connections ·
2 connectors 13 mm
Additional accessories
Interface modules: analog, RS 232/485, contact, Profibus
module
Options
Booster pumps
All types
Cooling thermostat RP 4050 C
In the case of the water-cooled Proline Kryomats, the process heat is 0 1 RP 3050 CW
dissipated with the use of facility cooling water. This largely prevents un- 2 RP 4050 CW
-20 3 RP 3090 CW
necessary heating of the surrounding environment. As a result of this type 4 RP 4090 CW
of cooling, even higher cooling capacities are achieved than with the air- -40
cooled units. The electronic cooling water management minimizes water 2
consumption. The booster pumps, available as options (ex works), are -60
4 1
particularly recommended for external applications where increased 3
-80
volume flow or greater pressures are required.
-100
0 10 20 30 40 50 60 70 80 90 100 min
Cooling time
Temperature range
-90...200 °C
Included accessories
Bath cover · 4 closing plugs for pump connections · G 3/4“
lock-nut with 1/2“ hose clip · 2 connectors 13 mm
Additional accessories
Tubing for cooling water · Interface modules: analog,
RS 232/485, contact, Profibus module
Options
Booster pumps
All types
Cooling thermostat RP 4090 CW
Proline accessories
Shut down valve/Reverse flow protection
Reverse flow protection when thermostating external systems, to avoid over-flow
when pump stops, for retrofitting with LiBus. Temperature range -40…140 °C
Solenoid valve
Water-conscious cooling on heating thermostats for cooling water control. Controlled
cooling operation for exothermal reactions or controlled cooling with programmer. Up
to 155 °C bath temperature.
Baskets
For notch bending test
LCZ 9661
Controlled high-temperature chiller HTC with LiBus
For controlled cooling of thermostats in the operating temperature range up to 300 °C
without formation of vapors, to be connected to external water cooling source.
Cat. No. Description
LCZ 9663 Controlled high-temperature chiller HTC
Proline Kryomats accessories
Interface modules
An RS 232/485 interface is integrated as a standard feature. The control head is
equipped for two interface modules to be plugged into the rear of the unit.
Suitable hoses/tubing for heat transfer liquids and for cooling water
Available upon request.
LZM 081 RKJ 031
Baskets
For notch bending test
Distributed by:
Accurate Thermal Systems
4106 Sylon Blvd
Hainesport, NJ 08036
Ph: 609-326-3190
Email: [email protected]
www.accuthermal.com