LIGUARD 2, 4 & 6
2, 4 & 6 READER
ACCESS CONTROLLERS
LIGUARD 2, 4 & 6 DESIGNED & MANUFACTURED
IN FRANCE
2, 4 & 6 READER
ACCESS CONTROLLERS
• Manages up to 10,000 users
Peripherals • Last 10,000 events saved on memory
• Native IP and Bus 485 connectors (C485FX-IP converter required
with the BUS 485)
OPTIMA Box or Sw • Printed, pluggable terminal blocks
Access control software • Offline functioning mode
• With or without power supply (230Vac - 60W - 13.8Vdc - 5A)
• Easy to install, metal housing
C485FX-IP • Compatible with Senatorfx.net and log.net
BUS / IP converter [Only for
controllers functioning with RS485
BUS communication mode] PRESENTATION
The LIGUARD series represents the latest advance in Eden Innovations’s
controller technology. These controllers come with 2, 4 or 6 readers, with or
without power supply, and now offer IP and BUS communication modes,
INFX & OUTFX making life easier for both distributors and installers. Compatible with
Extension modules
Wiegand (max. identifier length 32 bits) and Data Clock protocols, they
can manage almost all types of readers on the market (proximity, remo-
tely-controlled, long-range etc.).
These controllers manage specific door-unlocking, push button, and access
COMMERCIAL REFERENCE right conditions for each reader.
COMMERCIAL REFERENCE
LIGUARD 2, LIGUARD 4, LIGUARD 6.
Detailed Technical Features 5 YEARANSTY
WARR
WITHOUT POWER SUPPLY WITH POWER SUPPLY
Liguard 2 Liguard 4 Liguard 6 Liguard 2 Liguard 4 Liguard 6
BUS RS485 BUS RS485 BUS RS485 BUS RS485 BUS RS485 BUS RS485
Communication or IP or IP or IP Communication or IP or IP or IP
Alimentation 12 to 14 VDC 12 to 14 VDC 12 to 14 VDC Alimentation 110 to 230 VAC 110 to 230 VAC 110 to 230 VAC
Consommation 200 mA 200 mA 250 mA Consommation 200 mA 200 mA 250 mA
Dimension Dimension
195x190x45 195x190x45 230x195x45 350x230x95 350x230x95 350x230x95
(in mm) (in mm)
Operating T° Operating T°
range 0 to 40°C 0 to 40°C 0 to 40°C range 0 to 40°C 0 to 40°C 0 to 40°C
Weight 1 kg 1 kg 1 kg Weight 3,2 kg 3,2 kg 3,2 kg
Command 30 V max 30 V max 30 V max Command 30 V max 30 V max 30 V max
relays 3 A max 3 A max 3 A max relays 3 A max 3 A max 3 A max
Battery N/A N/A N/A Battery 12 V, 7 Ah 12 V, 7 Ah 12 V, 7 Ah
connection connection
Certification CE CE CE Certification CE CE CE
Automated 1 2 2 Automated 1 2 2
Relays Relays