Efficor™

Thermal overload relays

Thermal overload relays


Setting range Fuses Box clamp terminals

AM gL-gG
Trip class 10 Min. A Max. A A A Use with Cat. no. Ref. no. Pack

0.16 0.26 2 2 ECRT1B10B 268996 5


0.25 0.41 2 2 ECRT1B10C 268997 5
0.40 0.65 2 2 ECRT1B10D 268998 5
Global contactors

0.65 1.10 2 4 ECRT1B10F 268999 5


1.00 1.50 4 6 ECRT1B10G 269000 5
1.30 1.90 4 6 EC09 ECRT1B10H 269001 5
1.80 2.70 6 10 ECRT1B10J 269002 5
EC12
2.50 4.00 8 16 ECRT1B10K 269003 5
4.00 6.30 12 20 EC18 ECRT1B10L 269004 5
5.50 8.50 16 20 ECRT1B10M 269005 5
8.00 12.00 20 25 ECRT1B10N 269006 5
10.00 16.00 25 35 ECRT1B10P 269007 5
14.50 18.00 32 50 ECRT1B10S 269008 5
17.50 22.00 40 63 ECRT1B10T 269009 5

8.00 12.00 20 25 ECRT2B10N 268103 5


10.00 16.00 25 35 ECRT2B10P 268104 5
14.50 18.00 32 50 EC25 ECRT2B10S 268105 5
17.50 22.00 40 63 EC32 ECRT2B10T 268106 5
21.00 26.00 40 63 EC40 ECRT2B10U 268107 5
25.00 32.00 50 80 ECRT2B10V 268108 5
30.00 40.00 63 100 ECRT2B10W 268109 5

Intro
Accessories

A Use with Description Cat. no. Ref. no. Pack

Base for separate mounting


ECRT1 DIN EN500022-35 ECRT1BS 268963 1
ECRT2 DIN EN500022-35 ECRT2BS 268964 1
B Push-button with flexible cable
ECRT1 0.5 m RTXS 113855 1
1m RTXSL 113856 1
backside reset RTXBS 108864 1

D Remote electrical reset


ECRT1 and ECRT2 12 VAC/DC RTXRRB 113661 1
24 VAC/DC RTXRRD 113662 1
48 VAC/DC RTXRRG 113663 1
110-240VAC/DC RTXRRJ 113664 1
220/415VAC/DC RTXRRN 113665 1
E 380/480VAC/DC RTXRRU 113666 1

J/X
Ne
w

A.14
Efficor™
Conformity to standards Ambient conditions
IEC/EN 60947-1 GB14048.4 Storage temperature -55ºC to +80ºC
IEC/EN 60947-4-1 UL508 Operation temperature -40ºC to +55ºC
IEC/EN 60947-5-1 UL486E -40ºC to +70ºC (1)
IEC/EN 60947-5-4 CSA2.22-14 Altitude <2000m
EN50011 NF F16 101/102
EN50012 (1) From 100% to 110% of rated control voltage, without additional
EN50005 auxiliary blocks

Approvals/Marking Climatic resistance (IEC 68-2)


(1) Continuous tests 40 / 125 / 56
Cold (72h)

Technical data
Temperature -40ºC
(1) (1) (1) Dry heat (96h)
Temperature +125ºC
Relative humidity < 50%
Humid heat (56h)
Temperature +40ºC
Relative humidity 95%
(1) In progress
Cyclic tests (6 cycles)
Humid heat
Mounting positions First half-cycle
Low temperature +25ºC
Installation capabilities Relative humidity 93%
Intro
30°
Second half-cycle
Low temperature +55ºC
Relative humidity 95ºC A
30°

With de-rating values


-10% connection voltage -10% disconnection B
voltage with same rated power, data
compared to vertical mounting

+10% disconnection voltage +10% connection C


voltage with same rated power, data
compared to vertical mounting

D
Terminal capacity and tightening torque
Conventional Thermal Current (lth) (A) Head type EC09 - EC18 EC25 EC32 - EC40 E
Box terminals 32 45 60
Solid, stranded and finely stranded w/o end sleeve (mm2) Slot & PZ2 0.75…6 0.75…10 0.75…16
Finely stranded with end sleeve
Finely stranded w/o end sleeve
(mm2)
(mm2)
Slot & PZ2
Slot & PZ2
0.75…6
0.75…6
0.75…10
0.75…10
0.75…16
0.75…16
F
AWG wires 18…10 18…8 18…6
Tightening torque (Nm) (Lb x in.) 2.2 / 20 2.2 / 20 2.2 / 20
G
Finely stranded w/o end sleeve (mm2) Slot & PZ2 0.75…6 0.75…10 0.75…16
AWG wires 18…10 18…8 18…6
Tightening torque (Nm) (Lb x in.) 2.2 / 20 2.2 / 20 2.2 / 20
H
Finely stranded with end sleeve (mm2) Slot & PZ2 0.75…6 0.75…10 0.75…16
AWG wires 18…10 18…8 18…6
Tightening torque (Nm) (Lb x in.) 2.2 / 20 2.2 / 20 2.2 / 20
I

J/X
w
Ne

A.15
Efficor™
Electrical endurance

Category AC1 (3P & 4P contactors) Category AC3 (3P contactors)

EC09 EC25 EC09 EC25


EC12 EC32 EC12 EC32
EC18 EC18 EC40
10.000.000 10.000.000
8.000.000 8.000.000
6.000.000 6.000.000

4.000.000 4.000.000
Global contactors

2.000.000 2.000.000

1.000.000 1.000.000
800.000 800.000
600.000 600.000
400.000 400.000 A
200.000 A 2 4 6 10 20 40 60 80 100 200
2 4 6 10 20 40 60 80 100 200
9 12 18 25 32 50 65 95 105
9 12 18 25 32 50 65 95 105

.
.

.
.
.
.

.
.

.
.
.

.
.

.
.

.
.

.
.

.
.

Intro
.

.
.

.
.

.
.

A
Category AC4 (3P contactors)
B
EC09 EC25
C 1.000.000
EC12
EC18
EC32
EC40

800.000
600.000

D 400.000

200.000

E 100.000
80.000
60.000
40.000
F 20.000
2 4 6 10 20 40 60 80 100 200
A

9 12 18 25 32 50 65 95 105

G
.

.
.

.
.
.
.

.
.

.
.

H
.

.
.

J/X
Ne
w

A.16
Efficor™
Power circuit
EC 09 EC 12 EC18 EC 25 EC 32 EC 40
Three pole version
Rated thermal current Ith at θ ≤ 55ºC (A) 25 25 32 45 60 60
Rated operational current Ie AC-3 (A) 9 12 18 25 32 40
Rated operational voltage Ue (V) 690V acc. IEC 60947-4-1 / 600V acc. UL-CSA
Four pole version
Rated thermal current Ith at θ ≤ 55ºC (A) - 25 32 45 60 -
Rated operational voltage Ue (V) 690V acc. IEC 60947-4-1 / 600V acc. UL-CSA
Three and four pole version
Rated insulation voltage Ui (V) 1000V acc. IEC 60947-4-1 / 600V acc. UL-CSA
Maximum continuous current AC-1 (A) 25 25 32 45 60 60
Frequency limits (Hz) 25…400 25…400 25…400 25…400 25…400 25…400

Technical data
Making capacity (RMS) (IEC- 60947) U = 500V (A) 220 220 220 315 520 520
Breaking capacity (RMS) (acc. IEC-60947)
Ue = 500V (A) 220 220 220 315 520 520
Ue = 690V (A) 120 120 120 144 232 232
Short-time current from cold state
1s (A) 570 570 570 790 1265 1265
5s (A) 254 254 254 355 565 565
10s (A) 180 180 180 250 400 400
30s (A) 104 104 104 145 231 231
1min (A) 74 74 74 102 164 164
3min (A) 42 42 42 60 95 95
Recovery time (min) 10 10 10 10 10 10
Protection against short-circuit with fuses without thermal overload relay
Intro
Coordination type 1
gL-gG (U = 500V, 50kA or U = 415V, 80kA) (A) 40 40 50 63 80 80
Coordination type 2 A
gL-gG (U = 500V, 50kA or U = 415V, 80kA) (A) 25 35 40 50 63 80
Average Impedance per pole (mΩ) 2.25 2.25 2.25 1.6 1.2 1.2
Power dissipation per pole
AC-1 (W) 1.41 1.41 2.30 3.24 4.32 4.32 B
AC-3 (W) 0.18 0.32 0.73 1.00 1.23 1.92
Insulation resistance
Between adjacent poles (MΩ) >10 >10 >10 >10 >10 >10
Between poles and earth (MΩ) >10 >10 >10 >10 >10 >10 C
Between input and output (MΩ) >10 >10 >10 >10 >10 >10

J/X
w
Ne

A.17
Efficor™
Control circuit - Alternating current
EC09 up to EC18 EC25 up to EC40
Rated insulation voltage Ui (V) 1000 1000
Standard voltages Us 50Hz (V) 12-600 12-600
Standard voltages Us 60Hz (V) 12-600 12-600
Voltage operating limits 50/60Hz coils
Operating 50Hz xUs 0.8 -1.1 0.8 -1.1
Operating 60Hz xUs 0.85-1.1 0.85-1.1
Pick-up 50Hz xUs 0.5...0.8 0.6...0.8
Pick-up 60Hz xUs 0.85-1.1 0.85-1.1
Drop out 50Hz xUs 0.35….0.55 0.30….0.55
Global contactors

Drop out 60Hz xUs 0.35….0.55 0.30….0.55


Maximum consumption bifrequency coils (cold state)
Magnetic circuit closed (50Hz/60Hz) (VA) 9.8 / 6.8 11.4 / 7.6
Magnetic circuit opened (50Hz/60Hz) (VA) 70.1 / 68.2 144 / 138
Power factor
Magnetic circuit closed cos ϕ 0.24 0.20
Magnetic circuit opened cos ϕ 0.85 0.70
Opening and closing times
Values between +10% Us and –20% Us
Making time on energisation (NO) (ms) 10 - 25 10 - 25
Breaking time on de-energisation (NO) (ms) 5 - 15 5 - 15
Values at Us
Making time on energisation (NO) (ms) 10 - 25 10 - 25
Making time on de-energisation (NO) (ms) 5 - 15 5 - 15
Intro Mechanical endurance
Bifrequency coils (at 50Hz) 106 ops. 10 10
Maximum rate
A AC-1 at rated power ops./h 1200 1200
AC-2 at rated power ops./h 1200 1000
AC-3 at rated power ops./h 1200 1000
AC-4 at rated power ops./h 360 240
B No load ops./h 7200 7200

C Control circuit - Direct current


Coils with Wide voltage range Coils with Low consumption
EC09 up to EC18 EC25 up to EC40 EC09 up to EC18 EC25 up to EC40
Rated insulation voltage Ui (V) 1000 1000 1000 1000
D Standard voltages Us DC (V) 12 - 400 12 - 400 12 - 400 12 - 400
Operating Limits
Operating xUs (VDC) 0.70 - 1.25 0.70 - 1.25 0.80 - 1.1 0.80 - 1.1
E Pick Up xUs
Drop Out xUs
(VDC)
(VDC)
0.45 - 0.65
0.12 - 0.30
0.45 - 0.65
0.12 - 0.30
0.48 - 0.68
0.12 - 0.30
0.48 - 0.68
0.12 - 0.30
Maximum consumption at Us
Magnet circuit open and closed (cold state) (W) 7.5 9.5 3.6 5.5
F Opening and closing times
Values between +10% Us and –20% Us
Making time on energisation (NO) (ms) 33 - 78 35 - 154 47 - 173 48 - 96
Breaking time on de-energisation (NO) (ms) 14 - 18 15 - 26 12 - 15 8 - 26
G Values at Us
Making time on energisation (NO) (ms) 33 - 78 35 - 66 44 - 83 33 - 75
Breaking time on de-energisation (NO) (ms) 14 - 18 15 - 24 13 - 20 12 - 24
Mechanical endurance
H 106 ops. 10 10 10 10
Maximum rate
AC-1 at rated power ops./h 1200 1200 1200 1200
I AC-2 at rated power ops./h 1200 1000 1200 1000
AC-3 at rated power ops./h 1200 1000 1200 1000
AC-4 at rated power ops./h 360 240 360 240
No load ops./h 7200 7200 7200 7200
J/X
(1) 4.4 for 230 Vdc version
Ne
w

A.18
Efficor™
Built-in auxiliary contacts
EC09 up to EC25
Rated insulation voltage Ui according to IEC 60947 (V) 1000
Rated thermal current Ith a θ ≤ 55ºC (A) 10
Making capacity (r.m.s.) acc. to IEC 60947
AC-15 Ue ≤ 400V, 50/60Hz (A) 105
DC-13 Ue ≤ 220Vdc (A) 105
Breaking capacity (r.m.s.) acc. to IEC 60947
AC-15 Ue ≤ 400V, 50/60Hz (A) 105
DC-13 Ue ≤ 220Vdc (A) 2
AC-15 rated voltage and current Ue-Ie (V-A) 110/120-10
according to IEC 220/230-10
380/400-6
415/450-5

Technical data
500-4
690/660-2
according to UL, CSA A600
DC-13 rated voltage and current Ue-le (V-A) 24-6
according to IEC 48-4
110-2
220-0.7
440-0.35
according to UL, CSA Q600
Electrical endurance 106 ops. 0.2
Minimum operational power (operational safety) 17 V - 5mA
Short-circuit protection Max. fuse class gl-gG without welding (A) 10
Insulation resistance Between contacts (MΩ)
>10
Intro
Between contacts and earth (MΩ)
Guaranteed no overlap between NO and NC contacts
Space 1.3mm
Impedance of the contacts (MΩ) 2.7 A

Auxiliary contact blocks


ECFA/ECLA B
Rated insulation voltage Ui according to IEC 60947 (V) 1000
Rated thermal current lth at θ ≤ 55ºC (A) 10
Making capacity (Ieff) according to IEC 60947
AC-15 Ue ≤ 400V, 50/60Hz (A) 60
C
DC-13 Ue ≤ 220Vdc (A) 60
Breaking capacity (Ieff) according to IEC 60947
AC-15 Ue ≤ 400V, 50/60Hz (A) 60 D
DC-13 Ue ≤ 220V, DC (A) 0.95
AC-15 rated voltage and current Ue-Ie (V-A) 110/120-6
according to IEC 220/230- 6
380/400-4 E
415/450-3.5
500-2.5
690/660-1.5
according to UL, CSA A600 F
DC-13 rated voltage and current Ue-Ie (V-A) 24-4
according to IEC 48-2
110-0.7
220-0.3 G
440-0.15
according to UL, CSA Q600
Electrical endurance 106 ops. 0.2
Mechanical endurance 106 ops. 10 H
Minimum operational current (operational safety) 17-5 V-mA
Short-circuit protection Max. fuse class gl-gG without welding (A) 10
Insulation resistance Between contacts
Between contacts and earth
(MΩ)
(MΩ)
>10 I
Guaranteed no overlap between NO and NC contacts
Space 1.6mm for ECFA / 2.2mm for ECLA
Impedance of the contacts (MΩ) 2.7 J/X
w
Ne

A.19
Efficor™
Mechanical latch blocks
Rated insulation voltage Ui (V) 1000
Standard voltages Us: 50 to 60Hz and DC (V) 24-660 & 24-440
Operating limits 85% to 110%
Consumption for unlatching (auto cut-out)
24 to 72V 30W / 25VA
110 to 440V 15W / 12VA
Electrical unlatching control 18
Minimum impulse (ms) 15 – 25
Maintained Auto cut by internal contact
Manual unlatching control By manual push-button
Electrical making control
Global contactors

Minimum pulse (ms) 40 (auto cut)


Manual making control By manual push-button
Auxiliary contact NC
AC-15 utilisation (V-A) 110/120-6
according to IEC 220/230-6
380/400-4
415/450-3.5
500-2.5
690/660-1.5
according to UL/CSA A600
DC-13 utilisation (V-A) 24-4
according to IEC 48-2
110-0.7
220-0.3
Intro 440-0.15
according to UL/CSA Q600
Mechanical endurance 106 ops. 0.2
A Wiring diagrams

B Alternating current

D
Alternating current / Direct current

F Terminal capacity
Terminal capacity Screw plate
ECMLSA,ECMLSD
G
Flexible wire (mm2) 2x0.5…2.5
AWG wire (mm2) 2x20…14
H Standard gauge A3
Tightening torque (Nm/Lb·in) 1.1 / 10

J/X
Ne
w

A.20
Efficor™
Thermal mechanical overload relays Manual RESET
for contactors from 0.16 to 40A
• Control circuit up to 690VAC
• Power circuit ECRT1, ECRT2: up to 690V
Manual RESET
• Thermal protection against balanced overload.
and STOP
• Three-pole differential (phase unbalance protection).
• Automatic ambient temperature compensation.
• Front mounted selector for choosing utilization current. Automatic
• Manual trip lever (tripping test). RESET with STOP
• Tripping indicator (0-1).
• IP20 protection
• Reset button, 4 positions: Automatic
- Manual RESET RESET without
STOP

Technical data
- Manual RESET and STOP
- Automatic RESET with STOP
- Automatic RESET without STOP
IEC/EN 60947-4-1
Ui=690V
Tripping current 120% of current setting

Standards
IEC 7 EN 60947-4-1
IEC EN 60947-5-1
GB14048.4
UL508
CSA22.2/14
Intro
VDE 0660

A
Approvals/Marking Tripping curves
(1)
Trip Time (s) B
(1) (1) (1)
C

D
Single phase
Cold state
(1) In progress E

F
Three phase
Cold state

Three phase
. Warm state H
.
.
I
Multiples of setting current

J/X
w
Ne

A.21
Efficor™
Thermal mechanical overload relays
Class 10A
Setting range (A) 0.16…40
Suitable for All Efficor contactors
Main circuit
Rated insulation voltage (V) 690
Frequency limits (Hz) 0-400
Control circuit
Rated insulation voltage (IEC60947-4) Ui (V) 690
Rated thermal current Ith (A) 10
Operation current
Global contactors

AC-15 - rated voltage and current Ue-Ie (V-A) 110/120-3 220/230-2 380/400-1 480/500-0.8 690/660-0.3
DC-13 - rated voltage and current Ue-Ie (V-A) 24-2 48-1.4 110-0.6 220-0.3 440-0.1
Utilisation according UL and CSA B600-Q600
Protective fuse type gL (A) 10
Terminal capacity (mm2) 0.75..10
Tightening capacity (Nm) 2.2 / 20

Terminal capacity
Clamp terminal - Flexible (mm2) 0.75…10
18..8
Clamp terminal - Standard gauge B6
Intro 2.2 / 20

A
Ambient conditions Remote electrical reset
B Storage temperature
Operation temperature (compensated)
-55ºC to +80ºC
-25ºC to +60ºC
Power consumption
AC 100VA
Altitude <2000 m without any changes DC 100W
in characteristics
C Relative humidity 40ºC, 95% no cond. Coils not suitable for continuous operating duty
Protection treatment Salt spary test

D
t1 = 1 sec. ♦ t2 = 30 sec.
E t1 = 5 sec. ♦ t2 = 90 sec.
t1 = 10 sec. ♦ t2 = 180 sec.
(t1 = ON time t2 = OFF time)

F
Mounting positions
G

Inclination angle axis Y and Z: ±30°


I

J/X
Ne
w

A.22
Efficor™
Coordination table Type 2 with 50kA at 415V and 500V
Current Setting range
415VAC 500VAC
Rated Power (kW)

Rated Power (kW)


With MCCB as SCPD With Fuse MMS as SCPD

Rated Current (A)

Rated Current (A)


"q" Current (kA)

"q" Current (kA)


"r" Current (kA)

"r" Current (kA)


Thermal
(Aac)

SCPD
Overload SCPD Contactor Contactor SCPD Contactor
(MCCB)
Relay
Rat. Rat. Rat. Rat. Rat. Rat.
Type Type Type Type Type Type
(Aac) (Aac) (Aac) (Aac) (Aac) (Aac)

0.16 -
ECRT1B10B 0.06 0.21 1 80 MMS 0.26 EC09A3 9 - - - - 0.06 0.17 1 50 MMS 0.26 EC09A3 9
0.26

0.25 -
ECRT1B10C 0.09 0.31 1 80 Fuse 2 EC09A3 9 - - - - 0.12 0.33 1 50 Fuse 2 EC09A3 9
0.41

0.4 -
ECRT1B10D 0.12 0.4 1 80 Fuse 4 EC09A3 9 - - - - 0.18 0.48 1 50 Fuse 4 EC09A3 9
0.65

Technical data
0.65 -
ECRT1B10F 0.25 0.8 1 80 Fuse 4 EC09A3 9 - - - - 0.25 0.66 1 50 Fuse 4 EC09A3 9
1.1

1.0 -
ECRT1B10G 0.37 1.1 1 80 Fuse 6 EC09A3 9 - - - - 0.55 1.2 1 50 Fuse 6 EC09A3 9
1.5

1.3 -
ECRT1B10H 0.55 1.5 1 80 Fuse 6 EC09A3 9 - - - - 0.75 1.5 1 50 Fuse 6 EC09A3 9
1.9

1.8 -
ECRT1B10J 0.75 1.9 1 80 Fuse 6 EC09A3 9 - - - - 1.1 2.1 1 50 Fuse 6 EC09A3 9
2.7

2.5 -
ECRT1B10K 1.5 3.4 1 80 Fuse 10 EC09A3 9 - - - - 1.5 2.6 1 50 Fuse 10 EC09A3 9
4.0

4.0 -
ECRT1B10L 2.2 4.5 1 80 Fuse 16 EC09A3 9 - - - - 3 5.3 1 50 Fuse 16 EC09A3 9
6.3

5.5 -
Intro
ECRT1B10M 3 6.5 1 80 Fuse 20 EC09A3 9 - - - - 3.7 6 1 50 Fuse 20 EC09A3 9
8.5

ECRT1B10N/ 8.0 -
4 8 1 80 Fuse 25 EC09A3 9 MCCB 12.5 EC25A3 25 5.5 9 1 50 Fuse 25 EC09A3 9
ECRT2B10N 12
A
ECRT1B10P/ 10.0 -
5.5 11 1 80 Fuse 35 EC012A3 12 MCCB 12.5 EC25A3 25 7.5 12 1 50 Fuse 35 EC12A3 12
ECRT2B10P 16.0

ECRT1B10S/ 14.5 -
7.5 14.8 1 80 Fuse 40 EC018A3 18 MCCB 20 EC25A3 32 10 15.5 1 50 Fuse 40 EC18A3 18
ECRT2B10S 18.0 B
ECRT1B10T/ 17.5 -
- - - - - - - - - - - 11 18.4 3 50 Fuse 40 EC18A3 18
ECRT2B10T 22

21.0 -
ECRT2B10U
26
11 21 3 80 Fuse 50 EC025A3 25 MCCB 30 EC25A3 32 15 23 3 50 Fuse 50 EC25A3 25
C
25.0 -
ECRT2B10V 15 28 3 80 Fuse 63 EC032A3 32 MCCB 30 EC32A3 32 17.5 26.5 3 50 Fuse 63 EC32A3 32
32.0

ECRT2B10W
30.0 -
40
18.5 35 3 80 Fuse 80 EC040A3 40 MCCB 50 EC40A3 40 22 33 3 50 Fuse 80 EC40A3 40 D

Thermal overload relays, Trip Class: 10A


Rated operational voltage: 415Vac, 500Vac E
Rated insulation voltage: 690Vac
Rated frequency: 50Hz.
Rated duty: Eight hour duty
Pollution degree: 3
Rated conditional short-circuit protection device current: 80kA at 415Vac; 50kA at 500Vac
F

J/X
w
Ne

A.23
Efficor™
Surion GPS high breaking capacity (Thermal Magnetic). Coordination Type 2 - 65kA at 380/400 & 415V

Motor(1) Manual Motor Starter Contactor Box clamp Links


Minimum
Rated Rated Thermal Magnetic Smallest wire frontal electri-
Rated Power Cat.No. Series (2) Cat.No.
current (A) current (In) current current Cu (pvc) cal safety
clearence
Setting range 380/415V
kW 380/400V 415V (A) (A) (mm)
(A) (mm2)
0.06 0.23 0.21 GPS1BHAB 0.25 0.16-0.25 3.2 EC9A.. 0.75 20 ECM1AL25
0.09 0.34 0.31 GPS1BHAC 0.4 0.25-0.4 5.2 EC9A.. 0.75 20 ECM1AL25
0.12 0.44 0.4 GPS1BHAD 0.63 0.4-0.63 8.2 EC9A.. 0.75 20 ECM1AL25
Global contactors

0.18 0.65 0.63 GPS1BHAE 1 0.63-1 13 EC9A.. 0.75 20 ECM1AL25


0.25 0.9 0.8 GPS1BHAE 1 0.63-1 13 EC9A.. 0.75 20 ECM1AL25
0.37 1.25 1.1 GPS1BHAF 1.6 1-1.6 20.5 EC9A.. 0.75 20 ECM1AL25
0.55 1.6 1.5 GPS1BHAF 1.6 1-1.6 20.5 EC9A.. 0.75 20 ECM1AL25
0.75 2 1.9 GPS1BHAG 2.5 1.6-2.5 32.5 EC9A.. 0.75 20 ECM1AL25
1.1 2.6 2.5 GPS1BHAH 4 2.5-4 52 EC9A.. 0.75 20 ECM1AL25
1.5 3.5 3.4 GPS1BHAH 4 2.5-4 52 EC9A.. 0.75 20 ECM1AL25
2.2 5 4.5 GPS1BHAJ 6.3 4-6.3 82 EC9A.. 0.75 20 ECM1AL25
3 7 6.5 GPS1BHAK 10 6.3-10 130 EC9A.. 1.5 20 ECM1AL25
4 9 8 GPS1BHAK 10 6.3-10 130 EC9A.. 1.5 20 ECM1AL25
5.5 12 11 GPS1BHAL 13 9-1.3 169 EC12A.. 2.3 20 ECM1AL25
7.5 16 14 GPS1BHAM 16 11.0-16 208 EC18A.. 4 20 ECM1AL25
11 22.5 21 GPS1BHAP 25 19-25 325 EC25A.. 6 20 ECM1AL25
15 30 28 GPS1BHAR 32 24-32 416 EC32A.. 6 20 ECM1AL32
Intro 18.5 37 35 GPS2BHAS 40 28-40 520 EC40A.. 10 20 ECM1AL32

(1) Current are relevant to four pole motors not having special characteristics of torque. Inrush currents: ≤ 8 time rated current for ≤ 1s.
A (2) The minimum cycle cross-sections are referred to an ambient temperature of 30ºC max. in free air and are selected to withstand the maximum let-through energy
and the motor rated current. Besides the user has to consider the drop voltage, the type of laying and ambient temperature.

J/X
Ne
w

A.24
Efficor™
Record Plus Coordination Type 2 at 80kA at 380/400 & 415V
Motor(1) MCCB Contactor Overload relay Box clamp Clearance

Min. frontal
Rated Rated Rated Thermal Magnetic Operating Admissible Setting Smallest wire Cu
electrical safety
Power current (A) Cat.No. current (In) Current Current current power Range (pvc)(2)
clearance

Setting 380/415V
kW 380/400V 415V (A) (A) Series A P(kW) Series mm
range (A) (mm2)
4 9 8 FD63 12.5 12.5 169 EC25A.. 25 11 ECRT2 8-12 1.5 20
5.5 12 11 FD63 12.5 12.5 169 EC25A.. 25 11 ECRT2 10-16 1.5 20
7.5 16 14.8 FD63 20 20 210 EC32A.. 32 15 ECRT2 14.5-18 4 20
11 22.5 21 FD63 30 30 300 EC32A.. 32 15 ECRT3 21-26 6 20
15 30 28 FD63 30 30 450 EC32A.. 32 15 ECRT3 25-35 6 20

Technical data
18.5 37 35 FD63 50 50 500 EC40A.. 40 18.5 ECRT3 30-40 10 20

Record Plus Coordination Type 2 at 80kA at 500/525V


Motor(1) MCCB Contactor Overload relay Box clamp Clearance

Min. frontal
Rated Rated Rated Thermal Magnetic Operating Admissible Setting Smallest wire Cu
electrical safety
Power current (A) Cat.No. current (In) Current Current current power Range (pvc)(2)
clearance

Setting 380/415V
kW 380/400V 415V (A) (A) A P(kW) Series mm
range (A) (mm2) Intro
7.5 12 FD63 12.5 12.5 - EC32A.. 32 15 ECRT2 10-19 4 20
11 18.4 FD63 20 20 - EC32A.. 32 18.5 ECRT3 17.5-25 6 20
15 23 FD63 30 30 - EC40A.. 40 18.5 ECRT3 21-29 6 20
18.5 29 FD63 30 30 - EC40A.. 40 18.5 ECRT3 25-35 10 20 A

(1) Current are relevant to four pole motors not having special characteristics of torque. Inrush currents: ≤ 8 time rated current for ≤ 1s.
(2) The minimum cycle cross-sections are referred to an ambient temperature of 30ºC max. in free air and are selected to withstand the maximum let-through energy
B
and the motor rated current. Besides the user has to consider the drop voltage, the type of laying and ambient temperature.

J/X
w
Ne

A.25
Efficor™

Contact sequence
Device Rating Basic contactor Built-in auxiliary Auxiliary contact blocks - Front mounted-4P
NO NC 40 .04 22
0 3.5 5 0 3.5 5 0 2 5 0 3 5
3P EC09
contactors EC12
3NO EC18
0 3 5 0 1.3 5 0 1.3 5

0 4 6 0 3.5 6 0 1.7 6 0 3 6
EC25

0 3 6 0 1.3 6 0 1.3 6
0 3 6
Global contactors

0 4 6
EC32
EC40

0 3 6 0 1.2 6 0 1.2 6

4P
contactors EC12
4NO EC18

0 1.5 6
0 3.3 5 0 3.3 5 0 3.3 5
4P EC09
contactors EC12
2NO+2NC EC18
Intro 0 4 6 0 4 6
0 1.7 5 0
0
1.7
4
5
6
EC25
EC32
EC40
A 0 2 6 0 2 6 0 2 6

B Contact sequence (auxiliary contactors)


ECAC09 0 3.3 5 0 3.3 5 0 3.3 5
4P
ECAC12
contactors
C 4NO
ECAC18
ECAC25 0 1.7 5 0 1.7 5
ECAC09 0 3.3 5 0 3.3 5 0 3.3 5
4P
ECAC12
contactors
D 2NO+2NC
ECAC18
ECAC25 0 1.7 5 0 1.7 5 0 1.7 5

J/X
Ne
w

A.26
Efficor™

Auxiliary contact blocks - Front mounted-2P Auxiliary contact blocks - Front mounted-2P
31 13 11 02 20 02 20 11

0 3 5 0 3 5 0 3.4 5 0 3.4 5 0 3.7 5 0 3.7 5

0 1.3 5 0 1.3 5 0 1.3 5 0 1.3 5 0 1.5 5 0 1.5 5

0 3 6 0 3 6 0 3.2 6 0 3.2 6 0 3.8 6

0 1.3 6 0 1.3 6 0 1.1 6 0 1.1 6 0 1.3 6 0 1.3 6


0 3 6 0 3 6 0 3.2 6 0 3.2 6 0 3.8 6 0 3.8 6

Technical data
0 1.2 6 0 1.2 6 0 1.1 6 0 1.1 6 0 1.3 6 0 1.3 6

0 3.5 6 0 3.5 6 0 3.5 6 0 3.5 6

0 1.5 6 0 1.5 6 0 1.5 6 0 1.5 6 0 1.5 6 0 1.5 6


0 3.3 5 0 3.3 5 0 3.3 5 0 3.3 5 0 3.3 5 0 3.3 5

0
0
1.7
4
5
6
0
0
1.7
4
5
6
0
0
1.7 5
4 6
0 1.7 5
0 4 6
1.7 5
0 4 6
0
0
1.7
4
5
6
Intro

0 2 6 0 2 6 0 2 6 0 2 6 0 2 6 0 2 6
A

B
0 3.3 5 0 3.3 5 0 3.3 5 0 3.3 5 0 3.3 5 0 3.3 5

0 1.7 5 0 1.7 5 0 1.7 5 0 1.7 5 0 1.7 5 0 1.7 5


C
0 3.3 5 0 3.3 5 0 3.3 5 0 3.3 5 0 3.3 5 0 3.3 5

0 1.7 5 0 1.7 5 0 1.7 5 0 1.7 5 0 1.7 5 0 1.7 5


D

J/X
w
Ne

A.27
Efficor™
Terminal numbering

3P and 4P contactors
EC09A311..EC25A311 EC32A300..EC40A300 EC12A400..EC32A400 EC12AB00…..EC25AB00 EC32AB00
EC09D311..EC25D311 EC32D300..EC40D300 EC12D400..EC32D400 EC12DB00…..EC25DB00 EC32DB00

1L1 3L2 5L3 13NO 21NC 1L1 3L2 5L3 1L1 3L2 5L3 7L4 R1 1L 3L R3 1L1 R1 R3 3L2
A1 A1 A1 A1 A1

A2 A2 A2
2T1 4T2 6T3 14NO 22NC 2T1 4T2 6T3 2T1 4T2 6T3 8T4 A2 R2 2T1 4T R4 A2 2T1 R2 R4 4T2
Global contactors

Auxiliary contactors
ECACA440 ECACA431 ECACA422 ECACA413 ECACA404
ECACD440 ECACD431 ECACD422 ECACD413 ECACD404
13 23 33 43 13 21 33 43 13 21 31 43 13 21 31 41 11 21 31 41
NO NO NO NO A1
NO NC NO NO NO NC NC NO NO NC NC NC NC NC NC NC
A1 A1
A1 A1

A2 A2 A2
14 24 34 44 14 22 34 44 A2 14 22 32 44 A2 14 22 32 42 12 22 32 42

Intro Auxiliary contact blocks - Front mounting


ECFA440 ECFA404 ECFA422 ECFA431 ECFA413

A 53 63 73 83 51 61 71 81 53 61 71 83 53 61 73 83 53 61 71 81

52 62 72 82 54 62 72 84 54 62 74 84 54 62 72 82
54 64 74 84
B
ECFA211 ECFA220 ECFA202
51 61
C 53 61 53 63

54 62 54 64 52 62
D
Auxiliary contact blocks - Lateral mounting
E ECLA20 ECLA11 ECLA02
73 83 73 81 71 81
(104) (94) (104) (92) (102) (92)

F
74 84 74 82 72 82
(103) (93) (103) (91) (101) (91)

G
Mechanical and mechanical/electrical interlock
ECMI ECMI02
H 01 01
(02) (02)

I 02 02
(01) (01)

J/X
Ne
w

A.28
Efficor™
Terminal numbering (continued)

Pneumatic timer blocks


ECPTD ECPTC

Voltage suppressor blocks

Technical data
ECSURC ECSUDI ECSUVI

Mechanical latch block


ECMLA ECMLD
c. alterna AC /DC Intro

J/X
w
Ne

A.29
Efficor™

Terminal numbering according to EN 50011


Possible basic auxiliary contactors +
Auxiliary contacts Description
NO NC
Auxiliary contacts blocks to be added

4NO auxiliary contactor terminal combination with 2P FRONTAL block


13 23 33 43
NO NO NO NO 51 61
A1
ECACA440
42E 4 2 ECACD440
+ECFA202
A2
14 24 34 44 52 62
13 23 33 43
Global contactors

A1
NO NO NO NO 53 63
ECACA440
60E 6 0 ECACD440
+ECFA220
A2
14 24 34 44 54 64
13 23 33 43
A1
NO NO NO NO 53 61
ECACA440
51E 5 1 ECACD440
+ECFA211
A2
14 24 34 44 54 62

4NO auxiliary contactor terminal combination with 4P FRONTAL block


13 23 33 43
NO NO NO NO 53 63 73 83
A1
ECACA440
80E 8 0 ECACD440
Intro A2
14 24 34 44 54 64 74 84
+ECFA440

13 23 33 43
A1
NO NO NO NO 51 61 71 81
ECACA440
A 44E 4 4 ECACD440
+ECFA440
A2
14 24 34 44 52 62 72 82
13 23 33 43
NO NO NO NO 53 61 71 83
A1
ECACA440
B 62E 6 2 ECACD440
+ECFA422
A2
14 24 34 44 54 62 72 84
13 23 33 43
53 61 73 83
C A1
NO NO NO NO
ECACA440
71E 7 1 ECACD440
+ECFA431
A2
14 24 34 44 54 62 74 84

D A1
13 23 33 43
NO NO NO NO 53 61 71 81
ECACA440
53E 5 3 ECACD440
+ECLFA413
A2

E 14 24 34 44 54 62 72 82

4NO auxiliary contactor terminal combination with LATERAL - block mounted on the RIGHT side of contactor
13 23 33 43 71 81
F A1
NO NO NO NO (102) (92)
ECACA440
42 4 2 ECACD440
A2
+ECLA202
14 24 34 44 72 82
G 13 23 33 43
(101) (91)
73 81
NO NO NO NO (104) (92)
A1
ECACA440
51 5 1 ECACD440
H A2
14 24 34 44 74 82
+ECLA211
(103) (91)
13 23 33 43 73 83
NO NO NO NO (104) (94)
A1

I 60 6 0
ECACA440
ECACD440
A2
+ECLA220
14 24 34 44 74 84
(103) (93)
J/X
Ne
w

A.30
Efficor™

Terminal numbering according to EN 50011 (continued 1)


Possible basic auxiliary contactors +
Auxiliary contacts Description
NO NC
Auxiliary contacts blocks to be added

4NO auxiliary contactor terminal combination with LATERAL - block mounted on the LEFT side of contactor
13 23 33 43 91 61
101
NO NO NO NO 51
A1
ECACA440
42 4 2 ECACD440
+ECLA202
A2
14 24 34 44 92 62
52 102
13 23 33 43
NO NO NO NO 91 103
53 61
A1
ECACA440
51 5 1 ECACD440

Technical data
A2
+ECLA211
14 24 34 44 54 62
92 104
13 23 33 43
NO NO NO NO 91
53 103
63
A1

6 6 0 ECACA440
ECACD440
A2
14 24 34 44
+ECLA220
54 104
92 64

4NC auxiliary contactor terminal combination with 2P FRONTAL block


11 21 31 41
NC NC NC NC 51 61
A1
ECACA404
06E 6 0 ECACD404
+ECFA202 Intro
A2
12 22 32 42 52 62
11 21 31 41
NC NC NC NC 53 63
A1
ECACA404
24E 2 4 ECACD404 A
+ECFA220
A2
12 22 32 42 54 64
11 21 31 41
A1
NC NC NC NC 53 61
ECACD404 B
15E 5 1 ECACA404
+ECFA211
A2
12 22 32 42 54 62
C
4NC auxiliary contactor terminal combination with 4P FRONTAL block
11 21 31 41
NC NC NC NC 53 63 73 83
A1

44E 4 4
ECACA404
ECACD404
D
+ECFA440
A2
12 22 32 42 54 64 74 84
11 21 31 41
A1
NC NC NC NC 51 61 71 81
ECACA404
E
08E 0 8 ECACD404
+ECFA404
A2
12 22 32 42 52 62 72 82
11 21 31 41
NC NC NC NC 51 61 71 81
F
A1
ECACA404
26E 2 6 ECACD404
+ECFA422
A2
12 22 32 42 52 62 72 82 G
11 21 31 41
NC NC NC NC 53 61 73 83
A1
ECACA404
35E 3 5 ECACD404
A2
+ECFA431 H
12 22 32 42 54 62 74 84

11 21 31 41
NC NC NC NC 53 61 71 81
A1
ECACA404
17E 1 7 ECACD404 I
+ECLFA413
A2
12 22 32 42 54 62 72 82

J/X
w
Ne

A.31
Efficor™

Terminal numbering according to EN 50011 (continued 2)


Possible basic auxiliary contactors +
Auxiliary contacts Description
NO NC
Auxiliary contacts blocks to be added

4NC auxiliary contactor terminal combination with LATERAL - block mounted on the RIGHT side of contactor
11 21 31 41 71 81
NC NC NC NC (102) (92)
A1
ECACA404
42 0 6 ECACD404
A2
+ECLA202
12 22 32 42 72 82
(101) (91)
Global contactors

11 21 31 41 73 81
NC NC NC NC (104) (92)
A1
ECACA404
15 1 5 ECACD404
A2
+ECLA211
12 22 32 42 74 82
(103) (91)
11 21 31 41 73 81
NC NC NC NC (104) (92)
A1
ECACA404
24 2 4 ECACD404
A2
+ECLA220
12 22 32 42 74 82
(103) (91)

4NC auxiliary contactor terminal combination with LATERAL - block mounted on the LEFT side of contactor
Intro A1
11 21 31 41
NC NC NC NC 91 61
51 101
ECACA440
42 4 2 ECACD440
+ECLA202
A A2
12 22 32 42 92 62
52 102

11 21 31 41
NC NC NC NC 91 103
9
91 103
03
A1
ECACA440
B 51 5 1 ECACD440
+ECLA211
A2
12 22 32 42 92
92 104
104

11 21 31 41
C A1
NC NC NC NC 93
53 103
63
ECACA440
6 6 0 ECACD440
+ECLA220
A2
12 22 32 42 54 104
94 64
D

J/X
Ne
w

A.32
Efficor™

Terminal numbering according to EN 50012


Possible basic auxiliary contactors +
Auxiliary contacts Description
NO NC
Auxiliary contacts blocks to be added

Terminal numbering according to EN 50012

1L1 3L2 5L3 13NO 21NC


A1

11E 1 1 EC09A311..EC25A311
EC09D311..EC25D311
A2
2T1 4T2 6T3 14NO 22NC

A1
1L1 3L2 5L3

Technical data
- 0 0 EC32A300..EC40A300
EC32D300..EC40D300
A2
2T1 4T2 6T3

FRONT mounted auxiliary contact blocks with 2 contacts each


1L1 3L2 5L3 13NO 21NC 51 61
A1
EC09A311..EC25A311
13 1 3 EC09D311..EC25D311
A2
+ECFA202
2T1 4T2 6T3 14NO 22NC 52 62

A1
1L1 3L2 5L3 13NO 21NC 53 63 Intro
EC09A311..EC25A311
31 3 1 EC09D311..EC25D311
A2
+ECFA220
2T1 4T2 6T3 14NO 22NC 54 64
A
1L1 3L2 5L3 13NO 21NC 53 61
A1
EC09A311..EC25A311
22 2 2 EC09D311..EC25D311
+ECFA211
B
A2
2T1 4T2 6T3 14NO 22NC 54 62

A1
1L1 3L2 5L3 51 61
EC32A300..EC40A300
C
02 0 2 EC32D300..EC40D300
A2
+ECFA202
2T1 4T2 6T3 52 62
D
A1
1L1 3L2 5L3 53 63
EC32A300..EC40A300
20 2 0 EC32D300..EC40D300
A2
2T1 4T2 6T3 54 64
+ECFA220 E
1L1 3L2 5L3 53 63
F
A1
EC32A300..EC40A300
11 1 1 EC32D300..EC40D300
A2
+ECFA211
2T1 4T2 6T3 54 64

G
LATERAL mounted auxiliary contact blocks with 2 contacts each - RIGHT side mounted
71 81
1L1 3L2 5L3 13NO 21NC (102) (92)
A1
EC09A311..EC25A311 H
13 1 3 EC09D311..EC25D311
A2
+ECLA220
2T1 4T2 6T3 14NO 22NC 72 82
(101) (91)

1L1 3L2 5L3 13NO 21NC


73 81
(104) (92)
I
A1
EC09A311..EC25A311
22 2 2 EC09D311..EC25D311
+ECLA211
A2
2T1 4T2 6T3 14NO 22NC 74 82 J/X
(103) (91)
w
Ne

A.33
Efficor™

Terminal numbering according to EN 50012 (continued 1)


Possible basic auxiliary contactors +
Auxiliary contacts Description
NO NC
Auxiliary contacts blocks to be added

LATERAL mounted auxiliary contact blocks with 2 contacts each - RIGHT side mounted (continued)
73 83
1L1 3L2 5L3 13NO 21NC (104) (94)
A1
EC09A311..EC25A311
31 3 1 EC09D311..EC25D311
A2
+ECLA220
2T1 4T2 6T3 14NO 22NC 74 84
(103) (93)
Global contactors

71 81
1L1 3L2 5L3 (102) (92)
A1
EC32A300..EC40A300
02 0 2 EC32D300..EC40D300
A2
+ECLA202
2T1 4T2 6T3 72 82
(101) (91)
73 81
1L1 3L2 5L3 (104) (92)
A1
EC32A300..EC40A300
11 1 1 EC32D300..EC40D300
A2
+ECLA211
2T1 4T2 6T3 74 82
(103) (91)
73 83
1L1 3L2 5L3 (104) (94)
A1
EC32A300..EC40A300
20 2 0 EC32D300..EC40D300
Intro A2
+ECLA220
2T1 4T2 6T3 74 84
(103) (93)

A LATERAL mounted auxiliary contact blocks with 2 contacts each - LEFT side mounted

1L1 3L2 5L3 13NO 21NC 91 61


51 101
A1

EC09A311..EC25A311
B 13 1 3
EC09D311..EC25D311
A2
2T1 4T2 6T3 14NO 22NC
+ECLA202
92 62
52 102

C A1
1L1 3L2 5L3 13NO 21NC 91 103
53 61

22 2 2 EC09D311..EC25D311
EC09A311..EC25A311
A2
2T1 4T2 6T3 14NO 22NC 54 62
+ECLA211
92 104
D
1L1 3L2 5L3 13NO 21NC 93
53 103
63
A1

31 3 1 EC09A311..EC25A311
EC09D311..EC25D311
E A2
2T1 4T2 6T3 14NO 22NC 54 104
64
+ECLA220
94

1L1 3L2 91 61
5L3 51 101
F A1

02 0 2 EC32A300..EC40A300
EC32D300..EC40D300
A2
2T1 4T2 6T3 52
+ECLA202
92 62
102

G 1L1 3L2 5L3 91 103


53 61
A1
EC32A300..EC40A300
11 1 1 EC32D300..EC40D300
+ECLA211
H A2
2T1 4T2 6T3 54 62
92 104

1L1 3L2 5L3 93


53 103
63
A1

I 20 2 0 EC32A300..EC40A300
EC32D300..EC40D300
A2
2T1 4T2 6T3 54 104
64
+ECLA220
94

J/X
Ne
w

A.34
Efficor™

Terminal numbering according to EN 50012 (continued 2)


Possible basic auxiliary contactors +
Auxiliary contacts Description
NO NC
Auxiliary contacts blocks to be added

FRONT mounted auxiliary contact blocks with 4 contacts each

1L1 3L2 5L3 13NO 21NC 53 63 73 83


A1
EC09A311..EC25A311
51 5 1 EC09D311..EC25D311
A2
+ECFA440
2T1 4T2 6T3 14NO 22NC 54 64 74 84

1L1 3L2 5L3 13NO 21NC 51 61 71 81


A1
EC09A311..EC25A311

Technical data
15 1 5 EC09D311..EC25D311
A2
+ECFA404
2T1 4T2 6T3 14NO 22NC 52 62 72 82

1L1 3L2 5L3 13NO 21NC 53 61 71 83


A1
EC09A311..EC25A311
33 3 3 EC09D311..EC25D311
A2
+ECFA422
2T1 4T2 6T3 14NO 22NC 54 62 72 84

1L1 3L2 5L3 13NO 21NC 53 61 73 83


A1
EC09A311..EC25A311
42 4 2 EC09D311..EC25D311
A2
+ECFA431 Intro
2T1 4T2 6T3 14NO 22NC 54 62 74 84

1L1 3L2 5L3 13NO 21NC 53 61 71 81


A1
EC09A311..EC25A311 A
24 2 4 EC09D311..EC25D311
A2
+ECFA413
2T1 4T2 6T3 14NO 22NC 54 62 72 82

B
A1
1L1 3L2 5L3 53 63 73 83
EC09A311..EC25A311
40 4 0 EC09D311..EC25D311
A2
2T1 4T2 6T3 54 64 74 84
+ECFA440 C

A1
1L1 3L2 5L3 51 61 71 81

04 0 4
EC09A311..EC25A311
EC09D311..EC25D311
D
A2
+ECFA404
2T1 4T2 6T3 52 62 72 82

1L1 3L2 5L3 53 61 71 83


E
A1
EC32A300..EC40A300
22 2 2 EC32D300..EC40D300
+ECFA422
A2
2T1 4T2 6T3 54 62 72 84 F
1L1 3L2 5L3 53 61 73 83
A1
EC32A300..EC40A300
31 3 1 EC32D300..EC40D300 G
A2
+ECFA431
2T1 4T2 6T3 54 62 74 84

A1
1L1 3L2 5L3 53 61 71 81 H
EC32A300..EC40A300
13 1 3 EC32D300..EC40D300
A2
+ECFA413
2T1 4T2 6T3 54 62 72 82
I

J/X
w
Ne

A.35
Efficor™
Dimensions and weights

Thermal overload relay ECRT1


186 g
ECRT1B
0.186 Kg

8.85 86.7 5.7

75
Global contactors

13.65

Thermal overload relay ECRT2


194 g
Intro
ECRT2B
0.194 Kg
8.85 83.7 5.7
A
74

B
60.5

35.3

J/X
Ne
w

A.36
Efficor™

Combination of contactor EC09A-12A-18A and thermal overload relay ECRT1


536 g
66.2
45

139.5

Technical data
38.7
96.7

Combination of contactor EC25A and thermal overload relay ECRT2


680 g 45
Intro
66

B
139.5

D
43.7
101.7
E
Combination of contactor EC32A-40A and thermal overload relay ECRT2
790 g
45 67.2
F

H
140

J/X
44.4
102.4
w
Ne

A.37
Series MTO
Thermal overload relays
for contactors from
0.11 to 14A
• Control circuit up to 690V
• Power circuit up to 690V
• Three-pole differential (phase unbalance protection)
Thermal overload relays

• Automatic ambient temperature compensation between


– 25ºC and + 60ºC
• Choice of manual or automatic reset
• Direct connection to contactor or independent mounting using accessories.
• Screw and Ring terminal versions
• Terminals protected against accidental contact in accordance with
VDE 0106 T.100 and VBG4.
• Terminal numbering in accordance with EN 50005
• Degree of protection IP20 (EN 60529)
• Additional auxiliary contact block 1NO (with manual reset only)

Intro Standards General characteristics


IEC/EN 60947-4-1 CSA 22.2/14 • Thermal protection against balanced overload.
IEC/EN 60947-5-1 NI C 63-650 • Three-pole differential (phase unbalance protection).
A UNE 115 VDE 0660 • Automatic ambient temperature compensation.
NFC 63-650 UL 508 • Front mounted selector for choosing utilisation current.
• Reset button, 2 positions :
Manual(H) and Automatic(A) by turning the blue selector.
B • Stop push button, independent of reset (red).
• Manual trip lever (tripping test).
• Tripping indicator (0-1).
C Approvals/Marking • To facilitate wiring arrangements terminal 96 fits directly onto coil terminal
(A2) and terminal 14/22 fits directly onto the feedback auxiliary contact.

D
cULus NEMKO CE

F SEMKO SETI

J/X
Order codes ! pg. A.69
Technical data ! pg. A.120
Dimensions ! pg. A.121

A.68
Series MTO
Thermal overload relays for contactors
For use with: Setting range Fuse Terminal: Terminal: Pack
(regulation) screw ring terminal
aM gL
Type 2 Type 1 Type 2 Type 1 Cat. no. Ref. no. Cat. no. Ref. no.
min. max.
A A A A A A
MC0... 0.11 0.17 0.5 0.5 0.5 0.5 MT03A 101000 MT03RA 103540 10
MC1... 0.17 0.26 0.85 1 1 1 MT03B 101001 MT03RB 103541 10
MC2... 0.26 0.43 1 2 2 4 MT03C 101002 MT03RC 103542 10
0.43 0.65 1 4 2 8 MT03D 101003 MT03RD 103543 10
0.65 1 2 6 4 12 MT03E 101004 MT03RE 103544 10
0.85 1,3 2 6 4 12 MT03F 101005 MT03RF 103545 10
1.1 1.6 2 10 4 16 MT03G 101006 MT03RG 103546 10
1.35 2 4 10 6 16 MT03H 101007 MT03RH 103547 10
1.7 2.4 4 16 6 25 MT03I 101008 MT03RI 103548 10
2.2 3.2 4 20 6 32 MT03J 101009 MT03RJ 103549 10
2.5 4 4 20 6 32 MT03R 101015 10
3 4.7 6 20 10 32 MT03K 101010 MT03RK 103550 10
4 6.3 10 32 16 50 MT03L 101011 MT03RL 103551 10

Order codes
5.5 8 12 50 20 63 MT03M 101012 MT03RM 103552 10
7.5 10.5 16 50 25 80 MT03N 101013 MT03RN 103553 10
10 14 20 32 32 100 MT03P 101014 MT03RP 103554 10

Accessories Intro
Terminal Cat. no. Ref. no. Pack

Input Screw MVE0T 101020 5


terminals Ring terminal MVE0R 103562 5
A

For separate mounting onto standard EN 50022-35 profile MVB0T 101021 5


B
Base

D
Auxiliary contact Frontal fixing to the relay Screw MATV10AT 101022 10
block With trip indicator (0-I) Ring terminal MATV10AR 103563 10
One block per relay and only for manual reset
E

F
Identification Sheets of labels (sheets of 260 labels each) EAT 260 100548 1
Labeling plate base (50 pieces in one pack) SPR 100549 1

J/X

A.69
Series RT
Thermal overload relays
for contactors from
0.16 to 850A
• Control circuit up to 690V AC
• Power circuit:
- RT1, RT12: up to 690V
Thermal overload relays

- RT2, RT22, RT3, RT32, RT4/4L, RT5/5L & RT6/6L: up to 1000V


• Thermal protection against normal overloads.
• Three pole differential (phase unbalance protection).
• Protection against long starting times.
• Automatic ambient temperature compensation between
– 25ºC + 60ºC.
• Front mounted test button.
• Trip indication.
• Independent auxiliary contacts with double rupture
(1NO + 1NC).
• Function selector:
- Manual RESET
- Manual RESET and STOP
- Automatic RESET with STOP
- Automatic RESET without STOP

Intro Standards
IEC/EN 60947-4-1 CSA 22.2/14
IEC/EN 60947-5-1 NI C 63-650
A UNE 115 VDE 0660
NFC 63-650 UL 508 Manual RESET
CEI 17-50

B Manual RESET
and STOP

C Approvals/Marking Automatic RESET


with STOP

D Automatic RESET
cULus CE without STOP

F Lloyd’s Bureau RINA


Register Veritas

G
(Contact GE for details)

J/X
Order codes ! pg. A.71
Technical data ! pg. A.122
Dimensions ! pg. A.123

A.70
Series RT
Thermal overload relays for contactors
For use Setting range Fuses (1) Srew Ring Pack
with: (regulation) terminal terminal
aM gL - gG

Cat. no. Ref. no. Cat. no. Ref. no.


min. max.
A A A A
Class 10A CL00 0.16 0.26 2 2 RT1B 113700 RT1RB 114087 5
CL01 0.25 0.41 2 2 RT1C 113701 RT1RC 114088 5
CL02 0.4 0.65 2 2 RT1D 113702 RT1RD 114089 5
CL25 0.65 1.1 2 4 RT1F 113703 RT1RF 114090 5
CL03 1.0 1.5 4 6 RT1G 113704 RT1RG 114091 5
CL04 1.3 1.9 4 6 RT1H 113705 RT1RH 114092 5
CL45 1.8 2.7 6 10 RT1J 113706 RT1RJ 114093 5
2.5 4.0 8 16 RT1K 113707 RT1RK 114094 5
4.0 6.3 12 20 RT1L 113708 RT1RL 114095 5
5.5 8.5 16 20 RT1M 113709 RT1RM 114096 5
8.0 12.0 20 25 RT1N 113710 RT1RN 114097 5
10.0 16.0 25 35 RT1P 113711 RT1RP 114098 5

Order codes
14.5 18.0 32 50 RT1S 113712 RT1RS 114099 5
17.5 22.0 40 50 RT1T 113713 RT1RT 114100 5
21.0 26.0 40 63 RT1U 113714 RT1RU 114101 5
25.0 32.0 50 80 RT1V 113715 RT1RV 114102 5
30.0 40.0 63 100 RT1W 113716 RT1RW 114103 5

Class 10 CL05 11.5 15.0 32 35 RT2A 113717 RT2RA 114104 1


CL06 14.5 19.0 40 50 RT2B 113718 RT2RB 114132 1
CL07 18.5 25.0 50 63 RT2C 113719 RT2RC 114106 1
24.0 32.0 63 100 RT2D 113720 RT2RD 114133 1
CL08
30.0 43.0 80 125 RT2E 113721 RT2RE 114134 1
CL09 42.0 55.0 100 160 RT2G 113722 RT2RG 114109 1
CL10 54.0
64.0
65.0
82.0
125
125
160
200
RT2H
RT2J
113723 RT2RH
113724 RT2RJ
114146
114136
1
1
Intro
78.0 97.0 125 200 RT2L 113725 RT2RL 114235 1
90.0 110 160 250 RT2M 113726 RT2RM 114113 1

Class 20 CL00 0.4 0.65 2 2 RT12D 139138 RT12RD 114060 5


A
CL01 0.65 1.1 2 4 RT12F 139139 RT12RF 114061 5
CL02 1 1.5 4 6 RT12G 139140 RT12RG 114062 5
1.3 1.9 4 6 RT12H 139141 RT12RH 114063 5
CL25
CL03
1.8
2.5
2.7
4.1
8
8
10
16
RT12J
RT12K
139142
113640
RT12RJ
RT12RK
114159
114114
5
5
B
CL04 4 6.3 12 20 RT12L 113641 RT12RL 114115 5
CL45 5.5 8.5 16 20 RT12M 113642 RT12RM 114116 5
8 12 20 35 RT12N 113643 RT12RN 114117 5
10
14.5
16
18
25
32
35
50
RT12P
RT12S
113644
113645
RT12RP
RT12RS
114118
114119
5
5
C
17.5 22 40 50 RT12T 113646 RT12RT 114120 5
21 26 40 63 RT12U 113647 RT12RU 114121 5
25 32 50 80 RT12V 113648 RT12RV 114122 5
30 40 63 100 RT12W 113649 RT12RW 114123 5 D
CL05 24 32 63 80 RT22D 113650 RT22RD 114124 1
CL06 30 43 80 100 RT22E 113651 RT22RE 114141 1
42 55 100 160 RT22G 113652 RT22RG 114126 1
CL07
CL08
54
64
65
82
125
125
160
200
RT22H
RT22J
113653
113654
RT22RH
RT22RJ
114127
114128
1
1
E
CL09 78 97 125 200 RT22L 113655 RT22RL 114143 1
CL10 90 110 160 250 RT22M 113656 RT22RM 114130 1

F
(1) Most suitable fuse in accordance with IEC 60947-4-1. (continued on page A.72)

J/X

A.71
Series RT
Thermal overload relays for contactors (continued)
For use Setting range Fuses (1) Cat.no. Ref. no. Pack
with: (regulation) (Screw terminal)
aM gL - gG

min. max.
A A A A
Class 10 CK75 55 80 125 200 RT3B 113727 1
CK08 63 90 125 200 RT3C 113728 1
Thermal overload relays

Direct 90 120 160 250 RT3D 113729 1


mounting 110 140 200 315 RT3E 113730 1
140 190 250 355 RT3F 113731 1

CK85 120 190 250 315 RT4N 113732 1


CK09 175 280 315 400 RT4P 113733 1
CK95 (2) 200 310 400 500 RT4R 113734 1

CK10 120 190 250 315 RT5A 113750 1


CK11 175 280 315 400 RT5B 113751 1
CK12 (3) 250 400 500 630 RT5C 113752 1
315 500 630 800 RT5D 113753 1
430 700 800 1000 RT5E 113754 1

CK13 (4) 500 850 100 1250 RT6A 113760 1

Class 20 CK75 63 90 125 200 RT32C 113657 1


CK08 90 120 160 250 RT32D 113658 1
Direct 110 140 200 315 RT32E 113659 1
ounting 140 190 250 355 RT32F 113660 1

Intro Class 30 CL...


CK...
2.5
4
4
6.5
10
12
16
20
RT4LA
RT4LB
113735
113736
1
1
Mounting 5.5 8.5 16 25 RT4LC 113737 1
with 7.5 11 20 32 RT4LD 113738 1
screws 10 16 25 40 RT4LE 113739 1
A 12.5
17
20
27
32
50
50
80
RT4LF
RT4LG
113740
113741
1
1
26 40 80 125 RT4LH 113742 1
32 52 100 160 RT4LJ 113743 1
45 70 125 160 RT4LK 113744 1
B 60
80
90
125
160
200
200
250
RT4LL
RT4LM
113745
113746
1
1
CK85 120 190 250 315 RT4LN 113747 1
CK09 175 280 315 400 RT4LP 113748 1
CK95 (2) 200 310 400 500 RT4LR 113749 1
C CK10 120 190 250 315 RT5LA 113755 1
CK11 175 280 315 400 RT5LB 113756 1
CK12 (3) 250 400 500 630 RT5LC 113757 1
315 500 630 800 RT5LD 113758 1
D 430 700 800 1000 RT5LE 113759 1

CK13 (4) 500 850 1000 1250 RT6LA 113761 1

E (1) Most suitable fuse in accordance with IEC 60947-4-1.


(2) Fitting direct to the contactor.
(3) Fitting direct to the contactor: by means of a coupling and connection set.
Separate mounting:with screws on DIN rail / with cable connection.
F (4) RT6A = RT1 with right setting range plus RTXP, independent mounting base adaptor, to be utilisied with current
transformer connected by passing cable chosen by customer. Current transformer data on request.

J/X

A.72
Series RT
Accessories
Cat. no. Ref. no. Pack

Base DIN EN50022-35


for separate RT1 RTXP 105170 1
mounting RT2 RT2XP 113764 1

Setting range RT... RTX3 113762 1


cover protection

Order codes
Push-button for distance RESET
with flexible cable RT1... - RT6.... (front) 0.5 meters RTXS 113855 1
RT1... - RT6.... (front) 1 meters RTXSL 113856 1
RT1..., RT2..., RT4..., RT5..., RT6... (back) RTXBS 108864 1

Terminal
protection
for RT3 or CK75C/CK08C
Thermal overload relay 1 pole IPxxB PTPCK75 103747 1
Intro
Connection contactor-relay 3 poles RT3PXX3P 110565 1

A
Remote electrical
Re RT1... - RT6... RTXRR ◆ 1
reset
B

Available coil voltages (V)


D
© B D G J N U X
AC/DC 12 24 48 110 220 380 440
240 415 480
E

J/X

A.73
Series RE
Electronic overload relays
Electronic overload relay

Approvals/Marking
Intro Product features Your benefits
Lower power consumption Saving space into cabinet
Great accuracy Better motor protection
A cULus CE
Full reliability Low risk to burn motor
Phase unbalance protection Better motor protection
B and current control
Direct fitting to contactors Series CL Compact starter
Interchangeable with thermal No need to redesign existing cabinet
C overload relay
Multiple trip class selection One device cover for start time motor
Manual / Auto reset One device for two solutions
D

E Main characteristics
• Setting range from 0.1 up to 150A
• Self powered
F • Thermal memory
• Phase loss protection
• Phase unbalance protection
G • Direct fitting to contactors Series CL
• Interchangeable with thermal overload relay
• Multiple trip class selection
• Manual / Auto reset
H • Increased flexibility, less order codes, less stock
• Tripp class: 5 - 10 - 20 - 30

J/X
Order codes ! pg. A.75
Technical data ! pg. A.128
Dimensions ! pg. A.130

A.74
Series RE

Electronic overload relays for contactors


Setting range (A) Fuses (A) (1)
Suitable for Min. Max. gL - gG Cat. no. Ref. no. Pack.

Frame 1 CL00…CL45 0,1 0,5 2 RE1D 101866 5


0,4 2 4 RE1H 101867 5
1,0 5 10 RE1K 101868 5
1,6 8 20 RE1M 101869 5
6,4 32 63 RE1S 101870 5
9,0 45 80 RE1W 101871 5

Frame 2 CL05…CL10 15 75 125 RE2H 101872 1


22 110 125 RE2M 101873 1

Order codes
Frame 3 CK75-CK08 30 150 250 RE3E 101874 1

Intro

Accessories A
Cat. no. Ref. no. Pack.

Transparent cover for For frames 1, 2 and 3 RETC 247795 10 B


pushbutton reset

Independent mounting
base adaptor
Frame 1 RE1XP 247302 1 C

Independent mounting
base adaptor
Frame 2 RE2XP 247303 1 D

E
(1) Most suitable fuse in accordance with IEC 60947-4-1, see coordination table on pg. A.128.

J/X

A.75
EntelliPro
Intelligent motor management relay
EntelliPro ES3 / ES5
• Motor protection and motor control
• Pre-programmed motor typicals
• Communication Interface to Profibus-DP and Modbus RTU system
Motor management relay

• Status information from motor and switchgear


• Maintenance information,
• Management of settings and configuration
• Predefined control logic
• Internal event recording with time stamping
• Local control and display devices

Protection
- Overload (Class 5 to 40)
- Earth fault (Residual current))
- Phase loss
- Thermistor (PTC)
- Start current
- Blocked rotor
- Under load
- Maximum starts per time
- Self monitoring
- External device monitoring
Intro Approvals/Marking
Diagnostic
- Time to overload trip, release
- Number of operations
A - Number of motor starts
SIL certified ATEX certified
- Motor ON-time, OFF-time
- Number of overload trips
B - Number of thermistor trips
- Maximum currents
CE
- Trip currents

C Drive typicals
- Direct-on-line
- Reverse
D - Star delta
- Star delta reverse
- Softstarter
- Softstarter reverse
E - Dahlander
- Pole changing starter
- Solenoid valve
- Actuator
F
Order information (see page A.77)
G
EntelliPro ES3 DP 2 2
H
ES3 = Standard device
ES5 = Medium device
I 2 = Power supply and 7 digital inputs, voltage 24V DC
3 = Power supply and 7 digital inputs, voltage 110-240V AC

J/X 0 = no additional 9 digital inputs available


Order codes ! pg. A.77
2 = additional 9 digital input, voltage 24V DC
Technical data ! pg. A.78
Ne

3 = additional 9 digital input, voltage 110-240V AC


Dimensions ! pg. A.80
w

A.76
EntelliPro
Intelligent motor management relay
Type Voltage Ref. No.
Standard device (I/O 7 digital inputs / 3 digital outputs)
EntelliPro ES3 DP 2 0 24V DC 720003
EntelliPro ES3 DP 3 0 240V AC 720004

Mid device (I/O 16 digital inputs / 8 digital outputs + 4–20 mA output)

EntelliPro ES5 DP 2 2 24V DC / 24V DC 720005


EntelliPro ES5 DP 2 3 24V DC / 240V AC 720006
EntelliPro ES5 DP 3 3 240V AC / 240V AC 720007

Order codes
Transformer
EntelliPro CT8 1,4A – 8A 720022
EntelliPro CT32 5,4A - 32A 720023
EntelliPro CT64 10,7A – 64A 720024
EntelliPro CT630 105A - 630A 720025

Intro

HMI Control panel A


EntelliPro CP3 HMI 3,3” LCD 720028
EntelliPro CP5 HMI 7” color TFT-LCD 720029

B
Parameterizing user software
WinESG V3 EntelliPro software tool for Windows 720020
C

E
Demonstration KIT
Demo-case Demonstration KIT for EntelliPro 720030
F

J/X
w
Ne

A.77
EntelliPro
Intelligent motor management relay
Overload tripping curves IEC 60947-4-1 (3-Pole / 3-Wire)
Motor management relay

10.000

1.000
Time (seconds)

100
Class E5

Class E10

Class E15

Class E20

10 Class E25

Class E30
Intro Class E35

A 1
1 10 100
x Motor Load (x In)

B Current Class E5 Class E10 Class E15 Class E20 Class E25 Class E30 Class E35 Class E40 Tolerance
(x In) (sec) (sec) (sec) (sec) (sec) (sec) (sec) (sec) (%)

C 1.2
1.4
314.70
156.93
734.29
366.16
1048.99
523.09
1363.68
680.01
1783.28
889.25
2097.98
1046.17
2412.67
1203.10
2832.27
1412.83
10
10
1.6 103.43 241.33 344.75 448.18 586.08 689.50 792.93 930.83 10
1.8 75.21 175.49 250.70 325.91 426.19 501.40 576.61 676.90 10

D 2
2.5
57.80
34.41
134.86
80.29
192.66
114.70
250.46
149.11
327.53
194.99
385.33
229.40
443.12
263.81
520.19
309.69
10
10
3 23.26 54.10 77.85 101.91 133.65 155.70 178.76 209.50 10
3.5 16.79 39.02 56.31 73.91 97.03 112.62 129.22 151.34 10

E 4
4.5
12.74
10.02
29.56
23.22
42.80
33.74
56.34
44.56
74.06
58.66
85.60
67.48
98.14
77.30
114.86
90.40
10
10
5 8.11 18.75 27.36 36.26 47.81 54.71 62.62 73.16 10
5.5 6.71 15.48 22.68 30.19 39.86 45.37 51.87 60.55 10

F 6
6.5
5.65
4.83
13.01
11.10
19.10
16.43
24.31
20.76
31.97
27.33
37.52
32.06
43.16
36.89
50.43
43.06
10
10
7 4.18 9.59 13.40 17.96 23.67 27.76 31.94 37.25 10
7.2 3.90 9.08 12.78 17.00 22.42 26.28 30.25 35.26 10

G 8
9
3.20
2.60
7.39
5.89
10.40
8.40
13.88
11.09
18.33
14.68
21.47
17.18
24.71
18.90
28.76
22.98
20
20
10 2.30 5.20 7.40 9.10 12.19 14.13 16.27 18.85 20

J/X
Ne
w

A.78
EntelliPro

Overload tripping curves IEC 60947-4-1 (2-Pole / 2-Wire)

10.000

1.000

Technical data
Time (seconds)

100
Class E5

Class E10

Class E15

Class E20

10 Class E25

Class E30

Class E35 Intro

1
0,1 1 10 100
A
x Motor Load (x In)

Current Class E5 Class E10 Class E15 Class E20 Class E25 Class E30 Class E35 Class E40 Tolerance
B
(x In) (sec) (sec) (sec) (sec) (sec) (sec) (sec) (sec) (%)

1
1.2
267.42
130.59
623.99
304.72
891.41
435.31
1158.83
565.91
1515.39
740.03
1782.81
870.63
2050.24
1001.22
2406.80
1175.35
10
10
C
1.4 83.87 195.69 279.56 263.43 475.25 559.12 642.98 754.81 10
1.6 59.72 139.35 199.07 258.79 338.42 398.14 457.88 537.48 10
1.8
2
45.12
35.46
105.27
82.75
150.39
118.21
195.51
153.67
255.67
200.96
300.78
236.42
345.90
271.88
406.06
319.17
10
10
D
2.5 21.73 50.71 72.45 94.18 123.16 144.90 166.63 195.61 10
3 14.76 34.44 49.20 63.97 83.65 98.41 113.17 132.85 10
3.5
4
10.70
8.13
24.98
18.97
35.68
27.09
46.39
35.22
60.66
46.06
71.36
54.19
82.07
62.32
96.34
73.15
10
10
E
4.5 6.39 14.90 21.29 27.67 36.19 42.57 48.96 57.48 10
5 5.15 12.02 17.17 22.33 29.20 34.35 39.50 46.37 10
5.5
6
4.25
3.56
9.91
8.31
14.15
11.86
18.40
15.42
24.06
20.17
28.30
23.73
32.55
27.29
38.21
32.04
10
10
F
6.5 3.03 7.06 10.09 13.12 17.16 20.18 23.21 27.25 10
7 2.80 6.30 8.79 11.70 15.47 17.88 20.94 24.36 10
7.2
8
2.60
2.20
6.05
4.90
8.42
6.80
11.09
9.14
14.66
12.09
16.92
13.78
19.83
16.22
23.07
19.04
10
20
G
9 1.75 3.80 5.66 7.21 9.61 10.98 13.00 15.05 20
10 1.66 3.50 5.30 6.39 7.87 8.98 12.19 14.01 20

J/X
w
Ne

A.79
EntelliPro
Dimensional drawings
EntelliPro ES3/ES5
Motor management melay

83,7
135 57

125 5,70
88
75,6

104,6
78
5,7
4,23

29

14,4 35 4,50
104,4 16,2

Transformers
Intro CT 8 - CT 32 - CT 64

40 104,5

A
K
L1 L2 L3
L1 k 72 r ed
ESW L1 L2 k 73 r ed
B 78 58
L3 k 74 r ed

L2

L3 71 black
C
Ø1
2

3 4,5

D 10,5 29

E
CT 630
20
F 12

60
41 73
G
16 K
110 Ø4,8
230
33
H L1 L2 L3
L1 k 72 red
L2 k 73 red
L3 k 74 red
EntelliPro
CT630
0

L3
Transformer

I L1
Wandler
Ø3

80 5,5
Ref-No. XXX XXX

L2
CT630A / IGrC/660
CT.. plug
an/to ES...
71 727374
Terminal
Anschluss
www.ge.com/de
Made in Germany

CT630
20 71 black
74

73

72

71

J/X 74 | 73 | 72 | 71
75 75
57 40
Ne
w

A.80
EntelliPro

Control panel
CP3

Unit: mm

Cut-out dimensions

Dimensions
Intro

CP5 C

Unit: mm 220.8 +0
-0.8 D

219.7 E
-0.8

Cut-out dimensions
165.8 +0

46.8
F
45.8
231 6.5
G

H
164.7
176

J/X
w
Ne

A.81
Series MTO
Technical data
General Mounting positions
• Thermal protection against balanced overload.
• Three-pole differential ( phase unbalance protection).
• Automatic ambient temperature compensation.
• Front mounted selector for choosing utilisation current.
Thermal overload relays

• Reset button, 2 positions :


Manual(H) and Automatic(A) by turning the blue selector.
• Stop push button, independent of reset (red).
• Manual trip lever (tripping test).
• Tripping indicator (0-1).
• To facilitate wiring arragements terminal 96 fits directly
onto coil terminal (A2) and terminal 14/22 fits directly
onto the feedback auxiliary contact.
Main circuit (poles)
MT0...
Rated insulation voltage (Ui) (V) 750
Conformity to standards according to IEC 947
IEC 60947-4 CEI 17-50 VDE660 Frequency (Hz) 0...400
UNE 115 NI C63-650 UL508 Power dissipation per pole (W) min. 1 / max. 2.5
NFC63-650 Terminal capacity
Screw M 3.5 (pozidrive head)
safety flange
Maximum capacity :
Approvals Solid (Ø mm) 2 x 2 wires
Intro UL CSA SEMKO Stranded without end sleeve (mm2)
Stranded with end sleeve
2 wires Ø 2.5
SETI NEMKO CE
pen (2 end sleeves) (mm2) 2 wires Ø 0.75
pen (1 end sleeve) (mm2) 2 wires Ø 1
A Ambient conditions Tightening torque (Nm)
1 wires Ø 2.5
0.8
Storage temperature -55ºC to +80ºC
Operation temperature -25ºC to +60ºC
Altitude up to 3000m Nominal values
B from 3000 to 4000m 90%Ie 80%Ue Control circuit (incorporated auxiliary contact)
from 4000 to 5000m 80%Ie 75%Ue MT0...
Degree of protection IP20
Protection treatment Tropical finish Rated insulation voltage (Ui) (V) 750
C according to IEC 947
Rated thermal current (Ith) θ ≤ 60ºC (A) 10
Tripping currents
Climatic resistance AC-15 Ue-Ie (V-A) 223-3, 380-2, 500-1
D Continuous tests 40 / 125 / 56 DC-13
Short-circuit protection
Ue-Ie (V-A)
(A)
60-0.5, 110-0.2, 220-0.1
6
Cold (72h)
Temperature -40ºC (max.glass gL fuse - w/h welding)
Dry heat (96h) Number and type of contacts
E Temperature
Relative humidity
+125ºC
< 50%
Humid heat (56 days)
Temperature +40ºC
F Cyclical tests
Relative humidity 95%

First half-cycle (12h)


Low temperature +25ºC Control circuit (auxiliary contact block)
Relative humidity 93%
G Second half-cycle (12h)
MATV10AT
Low temperature +55ºC Rated insulation voltage (Ui) (V) 750
Relative humidity 95% according to IEC 947
Number of consecutive cycles 6 Rated thermal current (Ith) θ ≤ 60ºC (A) 10
H Tripping currents
AC-15 Ue-Ie (V-A) 223-1, 380-0.5
DC-13 Ue-Ie (V-A) 60-0.1, 110-0.5
Short-circuit protection (A) 6
I (max.glass gL fuse - w/h welding)
Number and type of contacts

J/X

A.120
Series MTO
Dimensional drawings
Numbering of the terminals Thermal overload relay
MT0...

. .

Technical data
Tripping curves 0.091 kg

Trip Time (s)


Thermal overload relay
+ aux. contact block (front mounting)

Intro
Single phase
Cold state

Three phase
Cold state B
Independent mounting
of the thermal overload relay
C
Three phase
. Warm state

.
D
.

.
Multiples of setting current
.

E
.

.
. F

J/X

A.121
Series RT
Technical data
RT1... RT2... RT3... RT4.../ 4L... RT5.../ 5L... RT6.../ 6L...

General
Class 10A / 20 10 / 20 10 / 20 10 / 30 10 / 30 10 / 30
Setting range (A) 0.16 ... 40 11.5 ... 110 55 ... 190 2.5 ... 310 120 ... 700 500 ... 850
Suitable for CL00...CL45 CL05...CL10 CK75...CK08 CL,CK CK10...CK12 CK13
Thermal overload relays

Main circuit
Rated insulation voltage (V) 690 1000 1000 1000 1000 1000
(IEC947-4) Ui
Frequency limits (Hz) 0...400 0...400 0...400 50...60 50...60 50...60
Terminal capacity
Clamp terminal - solid (mm2) 16 50 120 - - -
Clamp terminal - flexible (mm2) 10 50 120 - - -
Flat terminal (mm) - - 25 x 5 - - 80 x 10
Passing by hole (wire) through C.T. core (mm2) - - - - 400 -
Passing by hole (bar) through C.T. core (mm) - - - 30 x 10 30 x 10 -
Tightening torque (Nm) 2.5 4.5 6.5 23 31.5 -

Control circuit
Rated insulation voltage (V) 690
(IEC60947-4) Ui
Rated thermal current Ith (A) 10
Operation current
AC-15 - Ue-Ie (V - A) 110/120 - 3 ; 220/240 - 2 ; 380/415 - 1 ; 480/500 - 0,8 ; 660/690 - 0,3
Intro DC-13 - Ue-Ie (V - A) 24 - 2 ; 48 - 1.4 ; 110 - 0.6 ; 250 - 0.3 ; 440 - 0.1
Utilisation according UL and CSA B600 - Q600
Protective fuse type gL (A) 10
Terminal capacity (mm2) 2.5
A Tightening capacity (Nm) 0.8

B Conformity to standards Remote electrical reset


IEC/EN 60947-4-1 NFC 63-650 NI C 63-650 Power consumption
IEC/EN 60947-5-1 CEI 17-50 VDE 0660 AC (VA) 100
UNE 115 CSA 22.2/14 UL 508 DC (W) 100
C Coils not suitable for continuous operating duty

Approvals
D cULus
LLoyd’s Register
RINA
Bureau Veritas
CE

t1 = 1 sec. ♦ t2 = 30 sec.
t1 = 5 sec. ♦ t2 = 90 sec.
E Ambient conditions t1 = 10 sec. ♦ t2 = 180 sec.
Storage temperature -40ºC to +70ºC
(t1 = ON time t2 = OFF time)
Operation temperature (compensated) -25ºC to +60ºC
Altitude up to 3000m w/o any changes
F Relative humidity
in characteristics
98%
Protection treatment Tropical finish

G
Mounting positions

J/X

A.122
Series RT
Tripping curves
RT1 Class 10A RT2 Class 10

Trip Time (s) Trip Time (s)

Technical data
Single phase Single phase
Cold state Cold state

Three phase Three phase


Cold state Cold state

Intro
Three phase Three phase
Warm state Warm state
. .
A
. .
. .
Multiples of setting current Multiples of setting current
B
RT12 Class 20 RT22 Class 20
C
Trip Time (s) Trip Time (s)

Single phase
Single phase
Cold state
F
Cold state

Three phase
Three phase
Cold state
G
Cold state

Three phase I
Three phase Warm state
Warm state
. .

. . J/X
. .
Multiples of setting current Multiples of setting current

A.123
Series RT
Tripping curves
RT3 Class 10 RT4 Class 10

Trip Time (s) Trip Time (s)


Thermal overload relays

Single phase
Single phase
Cold state
Cold state

Three phase
Cold state Three phase
Cold state

Intro
Three phase Three phase
Warm state Warm state
. .
A
. .
. .
Multiples of setting current Multiples of setting current
B
RT32 Class 20 RT4L Class 30
C
Trip Time (s) Trip Time (s)

F Single phase
Cold state Single-phase
Cold state

Three phase
G Cold state
Three phase
Cold state

I Three phase
Warm state
Three phase
Warm state

. .
J/X . .
. .
Multiples of setting current Multiples of setting current

A.124
Series RT
Tripping curves
RT5 Class 10 RT6 Class 10

Trip Time (s) Trip Time (s)

Technical data
Single phase Single phase
Cold state Cold state

Three phase Three phase


Cold state Cold state

Intro
Three phase Three phase
Warm state Warm state

. .
A
. .
. .
Multiples of setting current Multiples of setting current
B
RT5L Class 30 RT6L Class 30
C
Trip Time (s) Trip Time (s)

Single phase F
Cold state
Single phase
Cold state

Three phase Three phase G


Cold state Cold state

Three phase
Warm state Three phase I
Warm state

. .

. .
J/X
. .
Multiples of setting current Multiples of setting current

A.125
Series RT
Dimensional drawings
Thermal overload relay for contactors
RT1 - RT12 RT1 + RT XP
0.190 kg RT12 + RTXP
Thermal overload relays

.
. .
. . .

.
.

RT2 - RT22 RT2 + RT XP


0.400 kg RT22 + RTXP
.
.
. .

Intro
.

.
A . .

B
RT3 - RT32
0.900 kg
C

.
D

E
.

G
.

J/X

A.126
Series RT

Thermal overload relay for contactors


RT4LA...RT4LM
2.400 kg

. .

Dimensions
RT4/4LN...RT4/4LR
2.400 kg

Intro

A
. .

RT5 / 5L
0.875 kg
C
.
D

G
.

H
Remote electrical reset
RTXRR + ... X Z I
RT1 75 110
RT2 84 121
RT3 108 153
RT4
RT5
150
200
240
196 J/X

A.127
Series RE
Coordination tables

Coordination Type 2 - 65kA at 380/400V and 415V - 50/60Hz


MOTOR(1) BREAKER CONTACTOR OVERLOAD RELAY WIRE
Rated Rated current Cat. no. Rated Magnetic setting Magnetic Series Series Setting Smallest wire Min frontal
power current 1m current range Cu (PVC)(2) safety
380/400V 415V In Pick-up ±20% Im
Electronic overload relays

(kW) (A) # (A) (A) (A) (A) (mm2) (mm)


0.06 0.23 0.21 GPS1MHAB 0.25 - 3.3 CLOO RE1D 0.1-0.5 1 20
0.09 0.34 0.31 GPS1MHAC 0.4 - 5.2 CLOO RE1D 0.1-0.5 1 20
0.12 0.44 0.4 GPS1MHAD 0.63 - 8.2 CLOO RE1D 0.1-0.5 1 20
0.18 0.65 0.63 GPS1MHAE 1 - 13 CLOO RE1H 0.4-2.0 1 20
0.25 0.9 0.8 GPS1MHAE 1 - 13 CLOO RE1H 0.4-2.0 1 20
0.37 1.25 1.1 GPS1MHAF 1.6 - 20.8 CLOO RE1H 0.4-2.0 1 20
0.55 1.6 1.5 GPS1MHAF 1.6 - 20.8 CLOO RE1H 0.4-2.0 1 20
0.75 2 1.9 GPS1MHAG 2.5 - 32.S CLOO RE1K 1.5-5.0 1 20
1.1 2.6 2.5 GPS1MHAH 4 - 52 CL25 RE1K 1.5-5.0 1 20
1.5 3.5 3.4 GPS1MHAH 4 - 52 CL25 RE1K 1.5-5.0 1 20
2.2 5 4.5 GPS1MHAJ 6.3 - 81.9 CL25 RE1K 1.5-5.0 1 20
3 7 6.5 GPS1MHAK 10 - 130 CL25 RE1M 1.6-8.0 1.5 20
4 9 8 GPS1MHAK 10 - 130 CL25 RE1S 6.4-32.0 1.5 20
5.5 12 11 GPS1MHAL 13 - 169 CL25 RE1S 6.4-32.0 2.5 20
7.5 - 14 GPS1MHAM 16 - 208 CL25 RE1S 6.4-32.0 2.5 20
8.8 16 - GPS1MHAM 16 - 208 CL25 RE1S 6.4-32.0 2.5 20
11 22.5 21 GPS1MHAP 25 - 325 CL25 RE1S 6.4-32.0 4 20
15 30 28 GPS1MHAR 32 - 416 CL04 RE1S 6.4-32.0 6 20
11 22.5 21 GPS2MHAR 25 - 325 CL04 RE1S 6.4-32.0 4 20
15 30 28 GPS2MHAP 32 - 416 CL04 RE1S 6.4-32.0 6 20
18.5 37 35 GPS2MHAS 40 - 520 CL45 RE1W 9.0-45.0 10 20
22 - 40 GPS2MHAT 50 - 650 CL06 RE2H 15.0-75.0 10 25
44 -- GPS2MHAT 50 - 650 CL06 RE2H 15.0-75.0 10 25
30 60 55 GPS2MHAU 63 - 819 CL07 RE2H 15.0-75.0 16 25
Intro 35
45
65
85
60
80
FDH36MC080GD
FDH36MC1 OOGD
80
100
900-1300
1000-1500
1100
1400
CL08
CL09
RE2H
RE2M
15.0-75.0
22.0-110.0
25
25
25
30
55 - 100 FDH36MC1 OOGD 100 1000-1500 1400 CL10 RE2M 22.0-110.0 25 30
55 105 - FEH36MC125JF 125 1250-1875 1250 CL10 RE2M 22.0-110.0 25 30
75 138 135 FEH36MC200KF 200 2250-3350 2800 CK75 RE3E 30.0-150.0 50 40
A
Coordination Type 2 - 100kA at 500 - 525V - 50/60Hz
MOTOR(1) gL/gG Fuses EOL CONTACTOR WIRE
B Rated power Rated current Size Series Type Setting range Series PAC3 Seco min Safety clearance
500V 525V
kW (A) In (A) (A) (kW) (mm)
0.06 0.17 0.16 2 000 RE1 D 0.1-0.5 CLOO 5.5 1 20
0.03 0.24 0.22 2 000 RE1 D 0.1-0.5 CLOO 5.5 1 20
C 0.12
0.18
0.33
0.48
0.3
0.46
2
2
000
000
RE1
RE1
D
D
0.1-0.5
0.1-0.5
CLOO
CLOO
5.5
5.5
1
1
20
20
0.25 0.66 0.64 2 000 RE1 H 0.4-2.0 CLOO 5.5 1 20
0.37 0.3 0.85 4 000 RE1 H 0.4-2.0 CLOO 5.5 1 20
0.55 1.2 1.15 4 000 RE1 H 0.4-2.0 CLOO 5.5 1 20
D 0.75
1.1
1.5
2.1
1.45
1.3 6
4 000
000
RE1
RE1
H
K
0.4-2.0
1.5-5.0
CLOO
CLOO
5.5
5.5
1
1
20
20
1.5 2.8 2.6 10 000 RE1 K 1.5-5.0 CLOO 5.5 1 20
1.1 2.1 1.3 6 000 RE1 K 1.5-5.0 CL01 7.5 1 20
1.5 2.8 2.6 10 000 RE1 K 1.5-5.0 CL01 7.5 1 20
E 2.2
1.5
3.3
2.8
3.6
2.6
10
10
000
000
RE1
RE1
K
K
1.5-5.0
1.5-5.0
CL01
CL25
7.5
15
1
1
20
20
2.2 3.3 3.6 10 000 RE1 K 1.5-5.0 CL25 15 1 20
3 5.3 5 16 000 RE1 M 1.6-8.0 CL25 15 1 20
4 6.8 6.5 20 000 RE1 M 1.6-8.0 CL25 15 1 20
F 5.5
7.5
3.1
12
8.6
11.4
25
32
000
000
RE1
RE1
S
S
6.4-32.0
6.4-32.0
CL25
CL25
15
15
1.5
2.5
20
20
10 15.5 14.8 40 000 RE1 S 6.4-32.0 CL25 15 2.5 20
11 17.6 17 40 000 RE1 S 6.4-32.0 CL25 15 2.5 20
15 23 22 50 000 RE1 S 6.4-32.0 CL04 18.5 4 20
G 18.5
4
28.5
6.8
27
6.5
63
20
000
000
RE1
RE1
S
M
6.4-32.0
1.6-8.0
CL04
CL45
18.5
25
6
1.5
20
20
5.5 3.1 8.6 25 000 RE1 S 6.4-32.0 CL45 25 2.5 20
7.5 12 11.4 32 000 RE1 S 6.4-32.0 CL45 25 2.5 20
11 17.6 17 40 000 RE1 S 6.4-32.0 CL45 25 2.5 20
H 15
18.5
23
28.5
22
27
50
63
000
000
RE1
RE1
S
W
6.4-32.0
3.0-45.0
CL45
CL45
25
25
4
5
20
20
22 33 31.5 80 000 RE1 H 15.0-75.0 CL45 25 5 20
18.5 28.5 27 63 000 RE2 H 15.0-75.0 CL06 30 5 25
22 33 31.5 80 000 RE2 H 15.0-75.0 CL06 30 5 25
I 30
37
45
53
43
52
80
100
000
000
RE2
RE2
H
H
15.0-75.0
15.0-75.0
CL06
CL07
30
40
10
10
25
25
40 53 56 100 000 RE2 H 15.0-75.0 CL08 45 16 25
45 65 62 125 00 RE2 H 15.0-75.0 CL09 55 16 30
55 80 76 125 00 RE2 M 22.0-110.0 CL10 65 25 30
J/X 75
30
105
130
100
124
160
250
01/1
01/1
RE3
RE3
E
E
30.0-150.0
30.0-150.0
CK75
CK08
100
110
35/25
50
40
40

(1) Current are relevant to four pole motors not having special characteristics of torque.
(2) The minimum cycle cross-sections are referred to an ambient temperature of 30ºC max. in free air and are selected to withstand the maximum let-through
energy and the motor rated current. Besides the user has to consider the drop voltage, the type of laying and ambient temperature if it is different.

A.128
Series RE
Tripping curves
Class 5 Class 10

Trip Time (s) Trip Time (s)

1.000 1.000

Class 10
Class 5 Cold status
Cold status
100 100

Technical data
10 10
Class 10
Hot status

Phase loss and Phase Phase loss and Phase


unbalance Hot status unbalance Hot status
1 1

Class 5 Intro
Hot status

0.1 0.1
A
0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8

Multiples FLA Multiples FLA


B
Class 20 Class 30
C
Trip Time (s) Trip Time (s)

1.000 1.000
D

Class 30
Class 20
Cold status
Cold status E
100 100

10 10 Class 30
G
Class 20 Hot status
Hot status

H
Phase loss and Phase Phase loss and Phase
unbalance Hot status unbalance Hot status
1 1

0.1
0 1 2 3 4 5 6 7 8
0.1
0 1 2 3 4 5 6 7 8
J/X
Multiples FLA Multiples FLA

A.129
Series RE
Dimensional drawings
Frame 1
Electronic overload relays

45
14,1 12 8 9 8 9

37,8

85,5
69

79,9
57,5
33

24,7

15 15

Frame 2
Intro

A
21 21 65
45

B
16
83,5

C
111,5
107
44,5

67

2 T1 4 T2 6 T3

D
1,5

E
Frame 3
F
38 38

G
3
47,9

H
154,2
148,7
151,7
170

131,2
92,5
110

111,7
53,6

I
30

J/X 49
98
49

110
123

A.130
Series M
Wiring diagrams

Series M. Direct-on-line starter with


reset
Power circuit Control circuit Control by two or more push-buttons
Use of two phases
(single phase) Three phase

Wiring diagrams
Series M. Direct-on-line starter with
start/emergency stop push-button Intro
Power circuit Control circuit Control by two or more push-buttons
Use of two phases
Three phase
A
(single phase)

J/X

A.131
Series CL
Wiring diagrams

Series CL. Direct-on-line starter


Power circuit Control circuit Control by two or more push-buttons

Control by permanent contact


Motorstarters

(float, thermostat, pressure switch, ...)

Series CL. Direct-on-line starter


with reset push-button
Intro
Power circuit Control circuit Control by two or more push-buttons

Single phase Three phase


A

B (connection K1-95 must be removed)

Control by permanent contact

D (float, thermostat, pressure switch, ...)

E Series CL. Direct-on-line starter


with start/stop/reset push-button

F Power circuit Control circuit Control by two or more push-buttons


Single phase Three phase

G
(connection 95-13 must be removed)

H Control by permanent contact

I
(float, thermostat, pressure switch, ...)

J/X

A.132