For Council Submission Only: General Construction Notes
For Council Submission Only: General Construction Notes
WALL CONSTRUCTION:
PTT 618
140mm brickwork wall construction plastered and painted internally and
externally, Pre-cast lintels to be used over openings with a min. of 4no.
brick courses over. supply 2 layers galv. ladder type brick force
HS 189
HS 3011 XOX reinforcement to 2no. horizontal courses above and below window
openings for full length of wall. Lapped at intersections. Vertical and
horizontal DPC's to be provided at all openings. Stepped DPC to external
NORTH ELEVATION SOUTH ELEVATION walls terminating 150mm min. above natural ground. Vertical DPC to all
changes in floor Levels.
WINDOWS:
All glazing to be laminated safety glass. All window frames generally of
12000 setback 5500
anodised aluminium construction with openable sections as indicated on
elevations. All in accordance with SANS 10400 Part N and all
5435 1000 13555 3478 1200 823
ROOF NOTES: subregulations parts contained within.
140 5155 140 1740 12815 140 2565 90 2565 140
Anodised alumnium by specialist. Min. glass thickness to be 6mm
IBR roof sheeting on 75x50 purlin at max. 1000mm centres
140 1780 900 2475 140 1600 140 12815 140 1665 900 2655 140
fixed to 228x50 rafters fixed to 114x38 wall plate anchored to All glazing to be in accordance with PART "N" of the NBR. All glazing
6000 140 5155 140 1600 140 12815 140 1970 140 1000 140 1970 140 brickwork with galvanized whoop iron straps embedded into larger than 1sq.m in size or less than 500mm above FFL, to be SABS
brick min. 600mm. Rafters anchored into brickwork on approved safety glass.
ADJACENT ERF 6991
opposite end. rafter ends to be wrapped in DPM
31490 SITE BOUNDARY Cills to be plastered.
140
140
1000
2.1 high fire wall
LIGHT & VENTILATION:-
1800
140
140
C C All habitable rooms to have 10% of floor area natural light and 5% of floor
1040
3379
- -
3129
Gym Room
area natural ventilation.
140
A A DOORS:
3000
1200
- -
Toilet Bedroom 2 Bedroom 1
1899
W.C. Extg En Suite Extg Bedroom All door and windows openings to have prestressed concrete lintels
4500
110
tiles tiles
with min 4no. courses brickwork over. Internal semi-solid flush doors in
140
2061
90
braai
400
Toilet
2000
10629
90
FLOOR CONSTRUCTION or finished with an approved impervious finish.
3550
90
on well sealed 250 micron DPM on well compacted fill (Extended Dwelling)
2nd Dwelling A minimum of 50% of annual hot water heating shall be provided
400
Entertainment Area
SECTION B-B
3791
Lounge/Kitchennette window area / nett floor area x
by means other than electrical resistance heating
3201
100
Solar water geyser to be installed all in accordance with manufacturers
500
tiles
1500
4.92 / 54 m2 x 100 = 9.1%
fire place specifications, to comply with SANS 10252-1 and SANS 10254.
1M ZINC UNIT
3250
ROOF NOTES: (2nd Dwelling) Insulation to service pipes to have a min. R-value of 1.0
17181
W.C.
2060
800
140
140
B
1500
brickwork with galvanized whoop iron straps embedded into 4.77 / 47.6 m2 x 100 = 10.9%
3201
brick min. 600mm. Rafters built into brickwork on opposite end.
Domestic Quarters NO PART OF BUILDING TO ENCROACH NEIGHBORS
3791
(Domestic Quarters)
90
Toilet
2000 Safety glazed aluminum window
tiles ROOF ASSEMBLY
PVC gutter & downpipe
2533
Extg Garage CONSTRUCTION
2061
90
230*600mm
1200
140
2500
ceilings.
SECTION A-A TYPE OF WINDOWS AND GLASS
THIS DRAWING IS FOR THE USE OF COUNCIL SUBMISSION ONLY TO ENSURE THAT THE
5000
fixed to 228x50 rafters fixed to 114x38 wall plate anchored to All the panes in doors larger than 1 CONSTRUCTION PURPOSES
MH brickwork with galvanized whoop iron straps embedded into square meter or less than 300mm above
FFL to be glazed in safety glass having a
client
brick min. 600mm. Rafters built into brickwork on opposite end.
74 nominal thickness of not less 6mm. All MR & MRS HOETS
00 to Municipal rafter ends to be wrapped in DPM
SI connection other glazing to comply with Part N of
TE the SANS 10400.
architect
BO PC Lintol over opening
UN LIGHTING & POWER
DA Brick on edge cill
Y To be in accordance with SANS 204
RY
ITE BOUNDAR
26170 S
4.5.1. When the detailed alectrical and
Safety glazed aluminum window lighting layouts are prepared, use max
energy demand and energy consumption
PVC gutter & downpipe table for lighting in SANS 204 table 12
2533