0% found this document useful (0 votes)
33 views1 page

6SL3246 0ba22 1fa0

This document provides data and specifications for the SINAMICS Control Unit CU250S-2 PN. Key details include: - It operates on DC 24V power and has a maximum power consumption of 2A. - It supports various closed-loop control techniques including sensorless vector control. - Communication is via PROFINET and it complies with standards like UL, CE, and C-Tick. - It has IP20 protection, weighs 0.61kg, and has dimensions of 73mm x 199mm x 67mm.

Uploaded by

TetroVorin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
33 views1 page

6SL3246 0ba22 1fa0

This document provides data and specifications for the SINAMICS Control Unit CU250S-2 PN. Key details include: - It operates on DC 24V power and has a maximum power consumption of 2A. - It supports various closed-loop control techniques including sensorless vector control. - Communication is via PROFINET and it complies with standards like UL, CE, and C-Tick. - It has IP20 protection, weighs 0.61kg, and has dimensions of 73mm x 199mm x 67mm.

Uploaded by

TetroVorin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Data sheet for SINAMICS Control Unit CU250S-2 PN

Ordering data
6SL3246-0BA22-1FA0

Figure similar

Client order no. : Item no. :


Order no. : Consignment no. :
Offer no. : Project :
Remarks :

Electrical data Ambient conditions

Operating voltage via Ambient temperature

The Power Module DC 24 V Operation -10 ... 50 °C (14 ... 122 °F)

External power supply DC 20 ... 29 V Storage -40 ... 70 °C (-40 ... 158 °F)

Max. power consumption 2.00 A Relative humidity

Power loss 12.00 W Max. operation 95 %

Inputs/ outputs Communication

Standard digital inputs Communication PROFINET

Number 15 Closed-loop control techniques


Switching level: 0→1 11 V V/f linear / square-law / parameterizable Yes

Switching level: 1→0 5V V/f with flux current control (FCC) Yes

Fail-safe digital inputs V/f ECO linear / square-law Yes

Number 3 (Use of 2 × DI Standard) Sensorless vector control Yes

Vector control, with sensor Yes


Digital outputs
Encoderless torque control Yes
Number as relay changeover contact 2
Torque control, with encoder Yes

Output (resistive load) DC 30 V, 1 A Standards


Compliance with standards
UL, cUL, CE, C-Tick
(RCM)
Output (resistive load) DC 30 V, 1 A CE marking

Analog/ digital inputs Low-voltage directive 2006/95/EC

Number 2 (Differential input) Mechanical data


Analog outputs Degree of protection IP20

Number Net weight 0.61 kg


2 (Non-isolated output)
Width 73.0 mm
Connections
Height 199.0 mm
Signal cable
Depth 67.0 mm
Conductor cross-section 0.05 ... 1.50 mm² (30 ... 16 AWG)

Technical data are subject to change! There may be discrepancies between calculated and rating plate values.
Page 1 of 1 Generated Wed Jun 01 14:24:45 CEST 2016