0% found this document useful (0 votes)
54 views7 pages

Single Fiber Insertion Loss and Return Loss Test System Data Sheets en

- The PCT-rm is a single fiber insertion loss and return loss test system that combines the mOLM-C1 measurement module with an mSRC-C2 source module in a MAP-220C chassis. - It provides real-time, high repeatability testing for insertion loss and return loss on single fiber connectors. - Key features include a simple user interface, production throughput independent of measurement needs, and a modular design supporting multiple connector types.

Uploaded by

Eduardo Pentax
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
54 views7 pages

Single Fiber Insertion Loss and Return Loss Test System Data Sheets en

- The PCT-rm is a single fiber insertion loss and return loss test system that combines the mOLM-C1 measurement module with an mSRC-C2 source module in a MAP-220C chassis. - It provides real-time, high repeatability testing for insertion loss and return loss on single fiber connectors. - Key features include a simple user interface, production throughput independent of measurement needs, and a modular design supporting multiple connector types.

Uploaded by

Eduardo Pentax
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

VIAVI Solutions

Data Sheet

VIAVI
Single Fiber Insertion Loss
and Return Loss Test System
mOLM-C1 with PCT-rm Application Framework for MAP Series

PCT-rm is a MAP-220 based Insertion Loss (IL) and Return Loss (RL)
solution targeting single fiber connector applications in the lab and in
manufacturing. It is part of the broader MAP-Series Passive Connector
Test (PCT) solution family which provides test solutions across the
entire connectivity eco-system.

Building on the heritage of the classic JDSU RM


and RX meters, the PCT-rm leverages the industry Key Benefits
standard optical continuous wave reflection (OCWR) yy Real-time high repeatability system for IL and RL
test method. A patented real-time measurement yy Multi-language, simple user interface enables
engine enables measurement performance and speed direct deployment on production lines
that is independent of the number of measured yy PCT Control Centre, a PC application simplifying
wavelengths. Production throughput is maximized data management and report printing
independent of measurement need. A full range of yy Modular design supporting Multimode (EF
power meter connector adapters ensures the unit compliant), Single-mode, and tunable sources

can be configured for all connectivity applications. Applications


The PCT-rm is part of the extended MAP LightTest yy Single fiber connector manufacturing
family of solutions for passive components and yy Qualification testing of connectors and simple
broad band passive components
optical connectors. The Light Test series provides
application specific, integrated test solutions that Safety Information
leverage the power of the VIAVI MAP System. Built yy Complies to CE, CSA/UL/IEC61010-1, LXI Class
with specialized modules and assemblies of Light C requirements, meets the requirements of IEC
60825-1 (2014) Class 1M and complies with 21
Direct Modules.
CFR 1040.1 except deviations per Laser Notice
No. 50, July 2001
The PCT-rm is delivered by combining the mOLM-C1 measurement module with an mSRC-C2 source module in a
MAP-220C chassis, giving users all the capabilities they need for IL & RL testing in a compact system.

mOLM-C1 cassette

Large (3.5 inch), mSRC-C2 cassette


multi-language,
color touch screen

yy Two slot, benchtop chassis gives customers full yy The PC based asset management tool enhances the
access to the broader MAP series system capabilities. ability to collect and centrally store data on remote
network drives.
yy LXI compliant LAN connectivity
yy Multiple USB ports enable the integration of a USB
yy SCPI based remote commands over
foot pedal device to creates a simple yet ergonomic
ethernet or an optional GPIB interface
solution for manufactures.

2 Single Fiber Insertion Loss and Return Loss Test System


Measurement Modes

Instrument Mode
This measurement mode is designed to be always on and immediately available using the 3.5-inch LCD touch
screen on the controller or though remote VNC. One touch referencing for IL and RL is simple and intuitive.
Measurement resolution and averaging time are user controllable. The display can be configured to measure
absolute power, insertion loss or insertion loss AND return loss.

Measurements are done in parallel with all 4 wavelength results reported in less than 0.5s. IL and RL are measured
concurrently. A full range of on-board measurement management tolls are available to manage source integration
and calibration. In this mode, an external light source (like a tunable laser) can configured and used.

Simple large display shown in single and multi-wavelength mode. The capacitive touchscreen enables quick and efficient navigation.

Device Aware Mode


Unlike other instruments in this performance class, the PCT-rm is delivered with a fully integrated workflow
automation mode. DUT definition files and serial numbers can be pre-loaded to deliver a full production
automation environment. Connecting the PCT-rm to your corporate or instrument LAN enables test results to
be automatically uploaded to a shared directory. The DUT definition files can be centralized and shared amongst
multiple units. If rework is required, results can be reloaded on any unit matching the hardware profile required to
execute the test.

Example screens from DUT aware mode. Batch loads of serial numbers can be loaded. When testing the results can be
frozen with a simple touch prior to uploading. Results may only be uploaded if the pass the DUT test criteria.

3 Single Fiber Insertion Loss and Return Loss Test System


PCT Control Center
PCT Control Center is a free companion PC application, designed to maximize the value of the DUT Aware
measurement mode. It is delivered standard with the PCT-rm.

A simple, easy to use PC interface enables creating, editing and managing DUT definition files, report templates
and serial number batches. Files are saved to a shared directory and allows all PCT-rm units to use these files. If
network connectivity is not available, USB storage media can be used to transfer the information. Test results
can be uploaded, viewed, filtered and printed using both standard and editable HTML templates.

PCT Control Center is also compatible with the PCT-lite application which leverages the mORL-A1 measurement
engine. Users who wish to migrate to mandrel-free testing, can continue to use the Control Center application
and DUT files.

PCT Control Center is a simple PC application designed to simplify


management of the PCT-rm and PCT-lite based IL and RL systems.

DUT Manager
yy Create DUT
yy Load S/N
mOLM-C1
DUT Manager yy Export Test results
yy Share files amongst stations

Reports DUT definition & script

Remote Network
Drive
Test results

VIAVI
DUT
Files

Centralized User PC

Management and Report Generation Tester Interface

Multiple PCT-rm systems can share centrally managed and stored DUT definition files. Data is
automatically uploaded to a shared directory and can be printed using the Control Center report engine.

4 Single Fiber Insertion Loss and Return Loss Test System


Specifications
mOLM-C1 Cassette Optical Performance1
Parameters SMF MMF (50um)
Wavelength
1310 / 1550 nm
Wavelength Combinations 2 850 / 1300 nm
1310/1490/1550/1625nm
Wavelength accuracy +/- 20 nm
Multimode Launch conditions As per IEC 61280-4-1
Power Meter
Wavelength range 800-1650 nm
Fiber Type SMF and MMF with NA < 0.27
Dynamic Range +6 dBm to -70 dBm
Display resolutions 0.001 dB
Linearity +/- 0.015 dB +/-5 pW
Uncertainty at Reference Condition3 +/- 3.0%
Additional uncertainty due to polarization +/- 0.015 dB
Noise +/- 3 pW
Detector Return Loss (APC connector) > 65 dB
Insertion Loss4
All wavelengths measured in 0.5s
Max measurement speed (4 lambda)
Measured concurrently with Return Loss
Display resolution 0.001 dB
Display range 0 to -60 dB
Accuracy (> -8dBm reference power)
0 to - 40dB +/- 0.04 dB +/- 0.04 dB
-40 to - 50dB +/- 0.05 dB NA
Repeatability (> -10dBm reference power)
0 to - 40dB +/- 0.002 +/- 0.005
-40 to - 50dB +/- 0.005 NA
Return Loss4
All wavelengths measured in 0.5s
Max measurement speed (4 lambda)
Measured concurrently with Insertion Loss
Display dynamic range 10 to 80 dB 10 to 50 dB
Display resolution 0.01 dB
Accuracy (> -8dBm reference power)
10dB to 50dB +/- 0.03 dB +/- 0.3 dB
50dB to 65dB +/- 0.4 dB NA
65dB to -70dB +/- 1.0 dB NA
70dB to 75dB +/- 2.0 dB NA
Repeatability (> -10dBm reference power)
10dB to 50dB +/- 0.02 dB +/- 0.3 dB
50dB to 65dB +/- 0.4 dB NA
65dB to 70dB +/- 1.0 dB NA
70dB to 75dB +/- 2.0 dB NA

1. All optical measurements performed 60 minutes after power on in a controlled environment of 23±2°C. All uncertainties are 2σ values unless otherwise stated. Specifications not guar-
anteed outside operating wavelength limit of the optical power meter. The mSRC-C2 and mOLM-c1 shall be connected with the rigid jumper supplied with the system.
2. Peak wavelength defined per IEC 61280-1-3 2010 clause 3.1.3.
3. Power meter reference condition: Input fiber SMF-28, T= 23 ±5°C, spectral width of source < 6nm, -20dBm input power
4. Tested in wavelength cycling mode using specified mSRC-C2, performed within 5min of an IL reference and observed over 15min, ignores any PDL contribution from DUT

5 Single Fiber Insertion Loss and Return Loss Test System


Specifications Continued
220 x 88.2 x 387 mm
Dimensions (W x H x D)
(8.66 x 3.47 x 15.24 in)
Weight 8 kg (17.6 lbs)
CPU ARM AM335x
Controller Linux OS
4GB user flash memory
Field replaceable (co-packaged with Power supply)
3.5-inch color screen
Display
320 x 240 resolution
Ethernet 10/100/1000Base-T
Remote interface
GPIB (optional)
USB device support Mouse, keyboard, memory stick, foot pedal
Power and Safety
100 to 240 V AC, 50/60 Hz
Power Supply Auto-switching
Field replaceable (co-packaged with controller)
Power consumption 160 VA
Local Laser interlock Software password controlled
Environmental
Operating temperature 10 to 40°C
Storage temperature –30 to 60°C
Relative humidity 5 to 85% noncondensing

6 Single Fiber Insertion Loss and Return Loss Test System


Configurations and Ordering Information
The PCT-rm ships in a preconfigured package with all the required elements including the MAP-220C mainframe,
mOLM-C1 measurement module and applicable mSRC-C2. Other configurations are possible. For more information
on this or other products and their availability, please contact your local VIAVI account manager or VIAVI directly at
1-844-GO-VIAVI (1-844-468-4284) or to reach the VIAVI office nearest you, visit viavisolutions.com/contacts.

Order Code1 MAP-220 IL/RL Meter Variants


Single Mode Fiber, Dual Wavelength
MAP-RM-C13500FB-M100-MFA 1310/1550nm Basic FP laser, FC/APC
MAP-RM-C13500FP-M100-MFA 1310/1550nm FP laser with Temperature Control, FC/APC
MAP-RM-C13456FP-M100-MFA 1310/1490/1550/1625nm FP laser with Temperature Control, FC/APC
50um Multimode Fiber Solution
MAP-RM-C11308LP-M101-MFA 850/1300nm LED 50um MMF EF compliant, FC/APC

1. All systems include the interconnection jumper to connect mSRC and mOLM modules and one FC style power meter adaptor

The table below highlights commonly ordered options and spare parts. In addition, a complete range of single
ferrule, duplex, bare fiber power meter adaptors and matting sleeves are available. VIAVI also offers a range of
connector inspection tools. For additional options please contact your VIAVI Solutions sales consultant.
Accessories (Optional) Description
MAP-200CGPIB-A GPIB Interface Option
MAP-200C01 Rack-mount conversion kit
MAP-200C02 Benchtop conversion kit
MAP-200CLD-A Replacement LightDirect Controller
MAP-200A020 Hardened inter-connection jumper, SMF, FC/APC
MAP-200A021 Hardened inter-connection jumper, OM3, FC/PC
AC500 Replacement bulkhead adapter FC/PC
AC502 Replacement bulkhead adapter FC/APC

MAP-200A20 hardened interconnect jumper Power meter adaptors

Contact Us +1 844 GO VIAVI © 2019 VIAVI Solutions Inc.


(+1 844 468 4284) Product specifications and descriptions in this
document are subject to change without notice.
To reach the VIAVI office nearest you, mOLM-c1-pct-rm-ds-lab-nse-ae
VIAVI Solutions visit viavisolutions.com/contact 30187741 900 0719

viavisolutions.com

You might also like