PRODUCT SPECIFICATION
Cylindrical Lithium-ion Cell
LR2170LA
(Consumer Products)
Signature Date
Customer
Company Name:
Approval
Company Stamp:
Prepared By Checked By QA Approved By
TEL: (86)-0512-88605019
http://www.lishen.com.cn
Product Specification
Lishen Battery (Suzhou) Co., Ltd
REV: V0
TITLE: Cylindrical Lithium Ion Cell LR2170LA Page: 1 of 12
Date: 20201126
History of revision
Revision Date Originator Reason of Revision
0 26/11/2020 Zhang Zhenyu Original Release
- Lishen Confidential Proprietary and not be reproduced without written permission from Lishen Battery (Suzhou) Co., Ltd -
Product Specification
Lishen Battery (Suzhou) Co., Ltd
REV: V0
TITLE: Cylindrical Lithium Ion Cell LR2170LA Page: 2 of 12
Date: 20201126
1 SCOPE
The product specification has been prepared to specific the technical requirements, test methods and
precautions for the Cylindrical Lithium-ion Cell supplied by Lishen Battery (Suzhou) Co., Ltd. For technical
requirements other than this specification, please contact with Lishen Battery (Suzhou) Co., Ltd. for related
matters.
2 DESCRIPTION AND MODEL
2.1 Description Cylindrical Lithium Ion Cell
2.2 Model LR2170LA
3 GENERAL SPECIFICATIONS
Item Specification
4,000mAh(Normal), 3900mAh(minimum)
- Charge: 0.2C(0.8A), 4.20V, 0.02C(80mA) cut-off @ 25℃
3.1 Standard discharge capacity
- Discharge: 0.2C(800mA), 2.5V cut-off @ 25℃
3,900mAh (Normal), 3800mAh(minimum)
- Charge:1.5C(6A), 4.20V, 0.025C(100mA) cut-off @25℃
3.2 Rated discharge capacity
- Discharge: 10A, 2.5V cut-off @ 25℃
3.3 Nominal voltage 3.6V
3.4 Standard charge CCCV, 2A, 4.20 V, 200mA cut-off
3.5 Rapid charge CCCV, 6A, 4.20 V, 100mA cut-off
Standard charge:360min / 80mA cut-off (@ 25℃)
3.6 Charging time Rated charge: 70min / 100mA cut-off (@ 25℃)
3.7 Max. continuous discharge
45A (80℃ temperature cut-off)
(Surface temperature)
3.8 Discharge cut-off voltage 2.5V
Capacity ≥ 2,400mAh @300 cycles
(60% of the standard capacity @ 25℃)
3.9 Cycle life - Charge: 6A, 4.20V, CCCV 100mA cut-off@ 25℃
- Discharge: 35A,2.5V cut-off @ 25℃(80℃ cut-off)
Capacity recovery(after the storage) ≥ 3,510mAh
- Charge: 6A, 4.20V, CCCV 100mA cut-off @ 25℃
3.10 Storage
- Storage: 30 days (@ 25℃)
- Discharge: 800mA, 2.5V cut-off @ 25℃
- Lishen Confidential Proprietary and not be reproduced without written permission from Lishen Battery (Suzhou) Co., Ltd -
Product Specification
Lishen Battery (Suzhou) Co., Ltd
REV: V0
TITLE: Cylindrical Lithium Ion Cell LR2170LA Page: 3 of 12
Date: 20201126
3.11 Cell weight 65±2 g
Height: 70.5±0.2mm
3.12 Cell dimension Diameter: 21.2±0.2mm
3.13 Operating temperature Charge: 0 to 45℃
(Ambient) Discharge:-20 to 60℃
Charge: 0 to 50℃
3.14 Operating temperature (recommended recharge release <45℃)
(Surface) Discharge: -20 to 80℃
(must re-discharge release < 60℃)
1 year -20~25℃
3.15 Storage temperature 3 months -20~45℃
(30% SOC) 1 month -20~60℃
4 OUTLINE DIMENSION (UNIT: mm)
Dimension: Diameter 21.2mm±0.2mm, Height 70.5 mm±0.2mm. Refer to the attached drawing 1.
5 APPEARANCE
There shall be no such defect as deep scratch, flaw, crack, rust, leakage, which may adversely affect
commercial value of the cell.
6 TEST CONDITION AND DEFINITIONS
6.1 Measuring Equipment
6.1.1 Voltmeter
Inner impedance>1000Ω/V.
6.1.2 Ampere-meter
Total external resistance (ammeter and wire) <0.01Ω.
6.1.3 Slide caliper
The slide caliper should have a scale of 0.02mm.
6.1.4 Impedance meter
The impedance meter should be operated at AC 1kHz.
6.2 Environmental Conditions
Unless otherwise specified, all tests shall be performed at 25°C±2°C and humidity of 65%RH±20% RH.
The cells used for the test mentioned should be new ones delivered a week before at most.
6.3 Definitions :
C Rate (“C”): The rate (milliamperes) at which a fully charged cell is discharged to its end voltage in
one (1) hour.
7 CHARACTERISTICS
7.1 Charge method
- Lishen Confidential Proprietary and not be reproduced without written permission from Lishen Battery (Suzhou) Co., Ltd -
Product Specification
Lishen Battery (Suzhou) Co., Ltd
REV: V0
TITLE: Cylindrical Lithium Ion Cell LR2170LA Page: 4 of 12
Date: 20201126
7.1.1 The cell shall be charged at 0.2C constant current to 4.20V, then charge at 4.20V constant voltage
until the current decays to 0.02C.
7.1.2 The cell shall be charged at 1.5C constant current to 4.20V, then charge at 4.20V constant voltage
until the current decays to 0.025C.
7.2 Discharge method :
7.2.1 The cell shall be discharged at 0.2C constant current to 2.5 V.
7.2.2 The cell shall be discharged at 1.0C constant current to 2.5 V.
7.2.3 The cell shall be discharged at 35A constant current to 2.5 V.
7.3 Internal Impedance
The impedance measured as per 6.1.4 at 25℃.
Initial Internal Impedance ≤ 12 mΩ.
7.4 Discharge Rate characteristics
Cells shall be charged per standard charge method at 25℃±2℃. Discharge capacity is measured with
the various currents in under table and 2.5V cut-off. Each cell shall meet or exceed the requirements of
Table 1.
Table 1
10A 20A 30A 40A
100% ≥95% ≥93% ≥90%
7.5 Cycle Life
Charge cells per 7.1.1. Rest 15 minutes. Discharge per 7.2.2. Rest 15 minutes before recharge. The
text environmental temperature is 25℃±2℃. A cycle is defined as one charge and one discharge.
Discharge capacity shall be measured after 300 cycles.
Discharge capacity (300th Cycle) ≥80% of 1st Cycle Capacity
Charge cells per 7.1.1. Rest 15 minutes. Discharge per 7.2.3. Rest 30 minutes before recharge. The
text environmental temperature is 25℃±2℃. A cycle is defined as one charge and one discharge.
Discharge capacity shall be measured after 300 cycles.
Discharge capacity (300th Cycle) ≥60% of 1st Cycle Capacity (With 80℃ temperature of cell surface
cut)
7.6 Storage Characteristics
After charge as per 7.1.1, store the testing cells at 25℃±2℃ for 30 days. And discharge as per 7.2.1.
Then the same cell is fully charged as per 7.1.1 again and discharged a second time and measured
as per 7.2.1.
nd
The recovery discharge capacity(2 discharge capacity )≥90% of Initial capacity.
- Lishen Confidential Proprietary and not be reproduced without written permission from Lishen Battery (Suzhou) Co., Ltd -
Product Specification
Lishen Battery (Suzhou) Co., Ltd
REV: V0
TITLE: Cylindrical Lithium Ion Cell LR2170LA Page: 5 of 12
Date: 20201126
After charge as per 7.1.1, store the testing cells at 55℃±2℃ for 7 days. And discharge as per 7.2.1.
Then the same cell is fully charged as per 7.1.1 again and discharged a second time and measured
as per 7.2.1.
nd
The recovery discharge capacity(2 discharge capacity )≥90% of Initial capacity.
7.7 Temperature Characteristics
Cells shall be charged per standard charge method and discharged per 7.2.1. Cells, full charged, shall
be stored for 3 hours at the test temperature prior to discharging and then shall be discharged at the
test temperature. The capacity of a cell at each temperature shall be compared to the capacity
achieved at 25 ℃ and the percentage shall be calculated. Each cell shall meet or exceed the
requirements of Table 2.
Table 2
Temperature -20℃ -10℃ 0℃ 25℃ 60℃
Relative Capacity ≥60% ≥75% ≥80% 100% ≥95%
8 SAFETY
8.1 External Short-circuiting Test at 25℃
Cell charged per standard charge method, is to be short circuited by connecting the positive (+) and
negative (-) terminals with a total external resistance of 80±20mΩ. Stop the test when the cell
voltage falls below 0.1V and the cell case temperature has returned to a value within 10℃ of the
original testing temperature.
Criteria: No Fire, No Explosion
8.2 Overcharge Test
Cell charged per standard charge method, is to be overcharged with 18A to 20V while tapering the charge
current. Monitoring change of cell temperature during testing. Stop the test when cell temperature
decays to room temperature.
Criteria: No Fire, No Explosion
8.3 Heating Test
Cell charged per standard charge method, is to be placed in the hot oven. Store the testing cells
connecting with thermocouple in constant temperature box, heating the cells and box(speed of ascending
temperature is 5℃±2℃ per min) together at room temperature simultaneity, monitor the temperature
change of the box, keep for 30 minutes after the box temperature reaches 130℃±2℃,then stop the test.
Criteria: No Fire, No Explosion
8.4 Over-discharge Test
Cell charged per standard charge method, is discharged at constant current of 1C for 90min.
Criteria: No Fire, No Explosion
8.5 Crush Test
Cell charged per standard charge method, is to be crushed between two flat surfaces and with cell
- Lishen Confidential Proprietary and not be reproduced without written permission from Lishen Battery (Suzhou) Co., Ltd -
Product Specification
Lishen Battery (Suzhou) Co., Ltd
REV: V0
TITLE: Cylindrical Lithium Ion Cell LR2170LA Page: 6 of 12
Date: 20201126
longitudinal axis parallel to the flat surfaces of the crushing apparatus. The force for the crushing is to be
applied by a hydraulic ram with a 1.25 inch (32 mm) diameter piston. The crushing is to be continued
until a pressure reading of 2500 psig (17.2 MPa) is reached on the hydraulic ram, applied force of 3000
pounds (13 kN). Once the maximum pressure has been obtained it is to be released.
Criteria: No Fire, No Explosion
9 PACKAGING
Loading 64 cells per box, 2 boxes per case for a total of 128 cells. Sketch map refer to attached drawing 2.
10 OTHERS
Any matter not included in this specification shall be consulted between the both parties.
11 SHIPPING
The capacity of shipping cell is 30% SOC. The violent vibration, impaction, solarization, drenching should be
avoided during transportation
Attached 1: LR2170LA Cell Size Drawing
- Lishen Confidential Proprietary and not be reproduced without written permission from Lishen Battery (Suzhou) Co., Ltd -
Product Specification
Lishen Battery (Suzhou) Co., Ltd
REV: V0
TITLE: Cylindrical Lithium Ion Cell LR2170LA Page: 7 of 12
Date: 20201126
Attached 2: LR2170LA Packaging Sketch map Drawing
- Lishen Confidential Proprietary and not be reproduced without written permission from Lishen Battery (Suzhou) Co., Ltd -
Product Specification
Lishen Battery (Suzhou) Co., Ltd
REV: V0
TITLE: Cylindrical Lithium Ion Cell LR2170LA Page: 8 of 12
Date: 20201126
The following caution and warning should appear in manuals and/or instructions for users, especially at the point
of use.
HANDLING INSTRUCTIONS
FOR
LITHIUM ION RECHARGEABLE CELL
1 DESIGN CONSIDERATIONS FOR ELECTRIC CAR, CHARGER AND BATTERY PACK
1.1 Charging
1.1.1 Cell should be charged with constant current-constant voltage method. The charging voltage cannot
above 4.20V/cell and the charging cut-off current is greater or equal to 1/20C. Considering the control
deviation of the charger, the charging voltage must be less than 4.20V. Even under abnormal
conditions, the charging voltage should not above 4.23V to avoid overcharging. The cell cycle life will
be shortened by charging voltage above 4.20V.
1.1.2 Charger should be equipped with a complete charging detection device, which can through the timer,
current or open circuit voltage to detect the charged state of the cell. When it is detected the cell is
fully charged, the charging circuit should be cut off at time. Avoid trickle charging.
1.1.3 The cell should be charged within a temperature range of 0℃~ 45℃ at the specified current. When
the cell temperature exceeds this range, it should be rest until the temperature reaches the above
range before recharging.
1.2 Discharging
1.2.1 Discharge end voltage must be over 2.5V.
1.2.2 Discharge environment temperature range of the cell is -20℃ ~ 60℃ at specified current
(as per 3.7 in the specification). If surface temperature of the cell exceeds 80℃, the
discharge must be stopped .
1.3 Over-discharging
If the voltage is less than 2.5V/cell, the cell is considered to be over-discharged and cannot to be used.
1.4 Storage
The cell should be stored in the following specified range: low humidity (less than 70%RH), no corrosive
gases, no pressure and condensation on the cell, best temperature range is -20℃~20℃, best SOC is
25%-35%, and the voltage should be detected before use.
When stored within 1 month: -20℃ ~ 50℃
When stored within 3 months: -20℃ ~ 40℃
When stored within 12 months: -20℃ ~ 20℃
- Lishen Confidential Proprietary and not be reproduced without written permission from Lishen Battery (Suzhou) Co., Ltd -
Product Specification
Lishen Battery (Suzhou) Co., Ltd
REV: V0
TITLE: Cylindrical Lithium Ion Cell LR2170LA Page: 9 of 12
Date: 20201126
1.5 Precautions on battery pack design
1.5.1 Battery pack shape, mechanism and material
The battery pack should be designed to ensure that it cannot be charged by an unauthorized charger.
The battery pack should be designed to ensure that it cannot be connected with unauthorized equipment.
The positive and negative terminals of the battery pack should be designed to avoid short circuits or
reverse connection.
The battery pack should have a device with over-current protection function to avoid external short-
circuiting.
The positive and negative connection wires of the battery should no overlap.
The battery pack should be designed with anti-static function and can prevent the intrusion of dust, liquid,
etc.
The battery pack should be designed to ensure that the electrolyte cannot reach the protection circuit
board, even if the battery leaks.
The battery pack should be designed to ensure that the cell is fixed in the battery pack, cannot move.
The structure of the battery pack should be designed to ensure that the dent, deformation and other
mechanical stresses of the battery cannot be caused after the foreseeable fall.
The materials of battery pack such as double-sided tape and rubber should be verified for flammability.
The welding mold should be sealed with glue; if ultrasonic welding is used to seal the welding mold,
Lishen will not bear any responsibility.
1.5.2 Battery pack structure (battery pack limits the number of batteries used)
The number of parallel connections is unlimited, but the battery pack must pass the overcharge test (the
charging current of the overcharge test is the product of the maximum charging current of the charger
and the product of the parallel quantity).
The number of series connections is unlimited and the fuse is required.
The battery should be positioned away from the heating electronic components to avoid the deterioration
of battery performance.
Between the PCBA and the battery pack should be insulated by the insulation material (such as plastic
barrier to provide air isolation or non-conducting thermal insulation material).
1.5.3 Protection Circuit
The following protection circuit should be installed in the battery pack:
Overcharge protection. For safety and in order not to shorten the cycle life, the maximum overcharge
protection voltage for the single cells within each module should be less than 4.23V (including
tolerances).
Over-discharge protection. If the single cell voltage reaches 2.5V, the over-discharge protection should
cut off the discharge current, and the current consumption of the circuit should be set as small as
possible.
Overcurrent protection. If the discharge current of the single cell exceeds about 15A, the overcurrent
protection should cut off the discharge current circuit. To avoid over discharge in long-term storage, the
current consumption of the battery pack protection circuit should be set as small as possible. When it
has not been used for a long time, it is necessary to regularly check the remaining state of power and
ensure that the single cell in the battery pack cannot reach the over-discharge state.
1.5.4 Cell connection
- Lishen Confidential Proprietary and not be reproduced without written permission from Lishen Battery (Suzhou) Co., Ltd -
Product Specification
Lishen Battery (Suzhou) Co., Ltd
REV: V0
TITLE: Cylindrical Lithium Ion Cell LR2170LA Page: 10 of 12
Date: 20201126
The cell should not be soldered directly with other cells. Namely, the cell should be welded with leads
on its terminal and then be soldered with wire or leads to solder.
1.6 Cell usage
1.6.1 When cells are used in series and parallel connection, they need to use the same gear, the same batch
and the same state of charge. This information can be obtained from the inside and outside box labels.
Before using the cell, the voltage and internal resistance need to be detected and the cells should be
assembled according to its purpose. Lishen recommends that the cell voltage difference is within 10mV
and the internal resistance difference is within 4mΩ at least.
1.6.2 Check the voltage, internal resistance, protection circuit function, thermistor and thermal fuse of the
battery pack before shipment.
1.6.3 During the transfer of the cells to the assembly factory, special attention should be paid to prohibiting
causing damage from external forces during transportation. Lishen recommends that the same
transportation packaging is used during the transfer process, even if there is a process of opening the
package.
1.6.4 Don’t use damaged or leaked cells due to transport damage, drop, short circuit or other reasons.
2 SAFETY INSTRUCTIONS
The cell contains flammable substances such as organic solvents. Improper use may present the cell to
generate heat or fire, causing damage of the cell or personal injury. Please pay attention to the use of
prohibited items, while the protection device should be added to avoid cells accident by the abnormal use of
equipment. Before using lithium-ion rechargeable cells, please read the following safety instructions carefully.
In addition, lishen strongly recommends that these instructions are added to the user manual.
2.1 Dangerous matter
2.1.1 Don’t use or store the cell in high temperature environment (above 60℃). Don’t put it into fire, water or
make it moisture. Don’t repair or disassemble cells, there is a risk of causing fire, heat generation,
leakage or explosion.
2.1.2 Don’t place the cell in a chaotic manner, and keep away from conductive materials such as metal to
avoid short-circuit, and don’t reverse the positive (+) and negative (-) poles to use.
2.1.3 Don’t use non-specified charger and violate charging instructions. Charging under non-specified
conditions will cause the cell to overcharge or abnormal chemical reactions, causing heat generation,
smoke, rupture or fire.
2.1.4 Don’t connect the battery to an AC plug (outlet) or a car plug. The battery needs a specific charger. If
the battery is directly connected to the plug, the battery may fire, smoke, explode, or generate heat.
2.1.5 Don’t overcharge, over-discharge, puncture, hammer or step on the cell.
2.1.6 Don’t hit or throw the cell. If the cell falls, please dispose it as a waste product and don’t continue to use
it.
2.1.7 Don’t disassemble the cell. Otherwise, the battery will no longer be protected. The battery may fire,
smoke, explode or generate heat.
2.1.8 Don’t charge near high temperatures. If the battery is charged near a high temperature, the battery
cannot be recharged due to the protection circuit. In this case, the protection circuit may be interrupted,
the battery may fire, smoke, explode or generate heat.
2.1.9 Don’t use obviously damaged or deformed batteries, which may generate heat, smoke, rupture or fire.
- Lishen Confidential Proprietary and not be reproduced without written permission from Lishen Battery (Suzhou) Co., Ltd -
Product Specification
Lishen Battery (Suzhou) Co., Ltd
REV: V0
TITLE: Cylindrical Lithium Ion Cell LR2170LA Page: 11 of 12
Date: 20201126
2.1.10 Don’t solder on the cell directly. Overheat will cause deformation of the cell components such as
insulating gaskets, the cell may deform, leak, explode or fire.
2.1.11 Don’t reverse charge. The battery is reverse charged will occur abnormal chemical reaction. In addition,
there is an unpredictable high current may flow during discharge. The battery may generate heat,
smoke, rupture or fire.
2.2 Warning
2.2.1 Keep the battery away from babies and children. In case of swallowing the battery, please seek medical
immediately.
2.2.2 Don’t put the battery in a microwave oven or other cooking utensils. Due to the heating and electrical
shock of the microwave oven, the battery may fire, smoke, explode or generate heat.
2.2.3 Don’t mix use other batteries. The battery cannot be mixed used from different capacities, chemical
systems or manufacturers. Otherwise, the battery may fire, smoke, explode or generate heat.
2.2.4 Don’t use an abnormal battery. If there are obvious abnormalities, such as peculiar odor, heat
generation, deformity or discoloration, stop using the battery. Such batteries may be defective and if
used, they may cause fire, smoke, heat generation or explosion.
2.2.5 If the charging process cannot be ended, stop charging. If the battery cannot complete the charging
process within the specified time, stop the charging step. The battery may fire, smoke, explode or
generate heat.
2.2.6 Don’t use leaking batteries near flames. If the battery or the leaking battery produces a pungent odor,
keep the battery away from flames. The battery may be ignited or explode.
2.2.7 Don’t touch the leaking battery. If the liquid leaks from the battery gets into the eyes, it will cause serious
damage. If the leaked liquid gets into your eyes, flush your eyes with clean water and go to see a doctor
immediately. If the liquid is left in the eyes, it will cause serious damage.
2.2.8 To avoid short circuit or damage, please put the battery into a box or carton tightly.
2.2.9 Don’t store the battery together with metallic objects, such as keys, necklaces, hairpins, coins or
screws.
2.3 Precautions
2.3.1 Before using the battery, be sure to read the instruction. Please keep this instruction for future reference.
2.3.2 Don’t use or store batteries in high temperature environments, such as in a car under direct sunlight.
Otherwise, the battery may fire, smoke, explode or generate heat. At the same time, it may cause
degradation in battery performance and cycle life.
2.3.3 The battery pack has protection circuit. Don’t use batteries in a place where static electricity (over 100V)
is generated, it may damage the protective circuit. If the protection circuit of the battery pack is
damaged, the battery may fire, smoke, explode or generate heat.
2.3.4 The specified temperature range is 0 ℃ ~45 ℃ . Don’t charge the battery outside the specified
temperature range. Otherwise, it may cause heat generation, leakage, or serious damage. In addition,
it may cause degradation in battery performance and cycle life.
2.3.5 Before charging, be sure to read the charging method in the charger instruction.
2.3.6 In the first use, if the battery has an abnormal smell, heat generation or rust, please contact with the
supplier.
2.3.7 During charging and discharging, please keep away from flammable materials. Otherwise, it may cause
fire, smoke, explosion or heat generation.
- Lishen Confidential Proprietary and not be reproduced without written permission from Lishen Battery (Suzhou) Co., Ltd -
Product Specification
Lishen Battery (Suzhou) Co., Ltd
REV: V0
TITLE: Cylindrical Lithium Ion Cell LR2170LA Page: 12 of 12
Date: 20201126
2.3.8 If the electrolyte leaks from the battery and leaks onto clothes or skin, wash with water immediately.
Otherwise, it may irritate the skin.
2.3.9 If wires or metallic objects are abnormally connected to the battery, please completely seal and insulate
them. Otherwise, the battery may short circuit, fire, smoke, explode, or generate heat.
2.3.5 After use, please recycle the battery according to local laws and regulations.
3 DIDCLAIMER
3.1 Lishen is not responsible for any loss caused by breach of precautions in the specification.
3.2 Lishen is not responsible for any problems caused by design and mix of battery packs, electric cars and
chargers.
3.3 Lishen does not accept abnormal batteries caused by improper assembly.
3.4 Lishen is not responsible for any problems caused by using charging or discharging methods and
environment that are incorrect or inappropriate with the specifications.
3.5 Lishen is not responsible for any problems caused by force majeure (such as lightning, storm, flood, fire,
earthquake, etc.).
3.6 In order to standardize the use of sample batteries, the rights, obligations and responsibilities of each
customer and Lishen are clarified. Before using the battery, please read and understand the specifications
thoroughly. To ensure the safety of the battery, please contact Lishen for the design and application. If
there are special usage conditions (such as high current load, fast charging method, low temperature and
high temperature use), please contact with Lishen.
If you choose to use this cell, your use will be considered as an endorsement of the entire contents of this
instruction.
The right to modify, update and interpret this statement belongs to Lishen.
4 CONSULTATION
If you have any questions, please consult as follows:
Add: 88 Kunlun Mountain Road, Huqiu District, Suzhou City, Jiangsu, China--Lishen Battery (Suzhou)
Co., Ltd.
Tel No.: 86-0512-88605019
URL.:http://www.lishen.com.cn
- Lishen Confidential Proprietary and not be reproduced without written permission from Lishen Battery (Suzhou) Co., Ltd -