0% found this document useful (0 votes)
44 views

Digital Caliper

Digital Caliper Manual

Uploaded by

alainmarco33
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
44 views

Digital Caliper

Digital Caliper Manual

Uploaded by

alainmarco33
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 2
DIGITAL CALIPER OPERATING INSTRUCTION ¥.'Before using the Digital Caliper, clean the surface of the protective sticker with dry and clean cloth (or soaked with cleaning oil) 2.Never apply voltage on any part of Digital Caliper of engrave with an electroprobe for fear of damaging the electronics. 3. Take out the battery or turn off its switch if Digital Caliper wat state relengane” oe Resolution: 0.01mm, Power:One 1.5V button cell Measuring Speed:< 1.5m/s Working temperature:0~+40 ©. Relative humidity:<80% mperature:-10~+60 C Us ‘A: Automatism turnoff Three-button Digital C: Four-button MODE Digital Caliper ‘our-button ABS Digital Caliper 2. Internal Measuring Faces 3. LCD display screen 4. Locking Screw 5. Data Output 6. One 1.5V button cell 7. Battery Cover 8. Slider 9. Protective Sticker 40.Depth Measuring 11.External Measuring Faces 1.inch/mm Interchange(Inch/mm, Interchange/On Button) 13.0n/Zero Setting “Button 14.01 Button 15.Function Button(MODE,HOLD.ABS,TOL) ‘Automatism turnoff Three-button Digital Caliper!) D: Four-button HOLD Digital Caliper Four-button TOL Digital Caliper 1 setting at any position, easy to take ¥« Measurement 2. Metrie/inch system interchange at any position. 3. With data output interface, data can be input to a special printer or a computer via special cable for data Processing and printing. Interface working way:Synchronous serial Data:Binary code, 24bits, Each datum will be transferred Thi is 300ma(20ms in fact reading state). Transmitting time: 0.5ms. Four wires(trom left to right):Negative power(-), Clock pulse CP, Data D, positive Powert +). Pulse range of datar0"Level<0.2V, Level"1"> 1.3V. Glock Pulte CP: 90K Hx, affective for high elgctrcal vel 4. Special function: With data holding. play, f CracingMeximom and. Minimum velue during ‘measurements, conversion between relative and absolute measurement and tolerance zone setting, ‘+-Preparations: (1) Clean the surtace of the protective sticker(please refer to the above-mentioned instructions)and ail the ‘measuring faces. (2) Loosen the locking screw and move the slider to check whether the LCD and all the buttons work properly. 2.Measurement: (2) Press On/Off button to switch on the power. (2) Press mm/in button to select 9 desired unit eystem. (3) Move the slider to make two out touch gently. you can start measuring. 3.Operation of Special function button: (1) MODE Button, (a) DATA HOLDING: When any of H..S or M isn't displayed (in the state of awaiting order), press Mode button and H will be displayed. It shows value has been held unchanged. namely HOLD function. f it's difficult to read the Value on the spot. press this button to hold the value, ‘and then take the instrument out to read.After taking, tutton three times, Hwill disappear ‘canceled. The state of in other state. press MODE order can be also restored, (b) FAST DISPLAY te of awaiting order, press MODE button (©) TRACING MINIMUM VALUE In the state of awaiting order, prees MODE button twice to - then press ZERO button to display Fand S simultaneously. The insteument ie then in a state of tracing minimum value. (d) TRACING MAXIMUM VALUE Inthe state of awaiting order, press MODE button three times to display M, then press ZERO button to display F and M. The instrument is then in astate, of tracing maximum value. (2)HOLD Button Press HOLD button to display H. The displayed value will beheld unchanged, namely the HOLD function. Ifit’sdifficult to read on the spot, press this button to hold measured value and then take the instrument out to read. After taking the value, press this button nd then H disappears. The instrument then turns Into the state of normal measurement (9) ABS Button-..-Button for relative zero point and ‘absolute value interchangs be ina state of absolu ison. Press ABS button then the digital caliper feurement with the value being zero and ING’ being displayed, namely, setting relative zero point and being in a state of relative measurements. Press ABS button for a second time in'a state of absolute measurement again, keeping the original zero position unchanged. WEEE Directive & Product Dispos Sea BSronCagaent or tuned wo te supoer button one or more times and thé state of awaiting — (TOL Button.-.-Button for setting tolerance range Make sure the correct origin hos been aet and ne ;ngle mark appears, then press TOL button.« mark {s displayed; Move the sider to daplay ite maximum value press TOL button again, mark is displayed: move the Sider to display ts minimum valueiprese TOL for the last time, The triangle mark disappears and tolerance range rit hes en Feith lgges than if the workpiece being measured is bigger than the maximum value, the smark twinkles. ft shows It's Beyond the maximum value, If the workpiece being moasured is smaller than the minimum value, the ‘Fimark twinkles. lt shows it's beyond the minimum v IF the workplace is within the tolerance range, OK mark twinkles If shows the workpiece Is up to standard Abnormal display (digits flashing or even no display)shows a flat battery. To replace the battery, ust push the battery cover as the arrow directs and replace it with a new one. Please note the positive side of the battery must face out. Ifthe battery bought from a market doesnt work satisfactorily (The power may wear down because of its longterm storage or the battery's automatic discharge etc.),please do not hesitate fo contact the supplier. “Troubles | Possible causes | Solutions Flashin vce he bat [Bigenre [Low vottage | Replace the battery {Low voltage | 1 Replace the battery No display] 2 Boor contact | 2.Adjust and clean the Batery seat ‘ReEldenial roubel Take oul the balieny and pul Fixed ait “n creutt itback a Measurements Gy ALL 2 U _ ‘Sincteeweharge of mone management

You might also like