0% found this document useful (0 votes)
1K views23 pages

Runxin Multiport Control Valves

The document provides information about Runxin control valves produced by Hengshui Snowate Environmental Technology Co., Ltd. Runxin control valves integrate multiple valves into one unit, simplifying installation and reducing leak risks compared to traditional pipeline systems. Key features include a ceramic moving disk for sealing, a balanced pressure structure to reduce torque, and signal collection points for automated operation. The valves can operate under pressure and are suitable for water treatment applications.

Uploaded by

Edson
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views23 pages

Runxin Multiport Control Valves

The document provides information about Runxin control valves produced by Hengshui Snowate Environmental Technology Co., Ltd. Runxin control valves integrate multiple valves into one unit, simplifying installation and reducing leak risks compared to traditional pipeline systems. Key features include a ceramic moving disk for sealing, a balanced pressure structure to reduce torque, and signal collection points for automated operation. The valves can operate under pressure and are suitable for water treatment applications.

Uploaded by

Edson
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 23

RUNXIN

MULTIPORT
Hengshui Snowate Environmental
Technology Co., Ltd.

CONTROL VALVES

2023
EDITION FOR SNOWATE CATALOG

www.snowate.com
HENGSHUI SNOWATE
ENVIRONMENTAL Contents
TECHNOLOGY CO., LTD.

A TRUSTWORTHY SOURCING EXPERT


I Product Description 04-12

ON WATER TREATMENT FACILITIES Multiple-Valve-In-One 04


Structure – Features 06
Working Principle 08
As a senior sourcing expert on water treatment facilities and accessories, Hengshui
Snowate Environmental Technology Co., Ltd. has extensive water treatment expertise,
Applications & Industry 10
profound water treatment industry experience and a deep understanding of the Runxin Code System 12
water treatment industry purchasing demands. As a consequence, we are capable of
providing one-stop purchase and technical support on water treatment facilities and
accessories according to our customers' applications, thereby helping our customers
to shorten the procurement cycle, reduce procurement costs and maximize economic
benefits. II Control Valves 14-39

We integrate upstream supply chain products of the water treatment industry. In Manual Filter Control Valves 14
addition, we work with renowned suppliers and manufacturers. As a result, we can Automatic Filter Control Valves 16
continuously supply high-quality water treatment components and systems for Manual Softening Control Valves 19
customers across the world to meet the needs of a Wide Range of Applications, Automatic Softening Control Valves 21
Thereby Optimizing Water Resources and Promoting The Sustainable Development of
Continuous Water Supply Control Valves 26
The Global Environment.
P Series 33
Q Series 34
Floating Bed 35
Residential D Series 36
Special Application Control Valves 38
Bypass Valves Series 39

III Appendix 40

02 www.snowate.com www.snowate.com 03
Multiple-Valve-In-One
Runxin Control valves structure is an initial international technology. It
has past International Patent Cooperation Treaty. The research report
indicates this product is creative, novel and practical in industry. It has
VS
gotten patents in many countries such as USA, EU and so on.

RUNXIN MULTIPORT TRADITIONAL PIPELINE


CONTROL VALVES SYSTEM

High flatness ceramic Part balance pressure Signal collection points Simple installation with Complex connections and
moving disk and high structure can reduce the set on a circular surface less leak points many leak points
strength fixed disk pressure acting on the which can realize
Integrate multiple valves into one valve, which 5,7,11 and more valves pipe connections in
guarantee excellent sealing surface and reduce accurate positioning.
make the connection easier and more efficient filtering, softening and ion exchange systems
sealing the rotational torque
and significantly reduce leak risk . cause hard installation many potential leak points.

Easy Maintenance Hard Maintenance

Fewer connections make maintenance easy and Multiple connections make the leak risk increase.
fast. Just replace the worn accessory of Runxin Besides, the repair and maintenance will spend
control valves, which can save more costs and too many labor and downtime time costs.
increase efficiency.

Automatic Operation All-Manual Operation

Just set the process in advance, it can achieve Manually operate many valves open and close will
automatic operation. spend long time and easy to have internal water
mixing.

04 www.snowate.com www.snowate.com 05
04 www.snowate.com www.snowate.com 05
Structure – Features

A
B
Operate with Pressure
Hermetic Head Faces 8 7 8 6 7 5 6 4 5 3 4 2 3 1 2 1

Construction F F F F
Runxin valve uses two high-flatness sealing disks closely located respectively. When
switch the working positions, it could operate with pressure.

While some other valves which uses soft sealing element like rubber parts, it can't operate
Because of good corrosion resistance,
E E E E

with pressure. It needs to shut off the inlet valve before switching.
Runxin control valve has a very good
application in Anion/Cation ion-exchange
system. D D D D

Ceramic Moving Disk


C C C C
C
i. Ceramic Disk is sintered at 1680 °C. No Hard Water Bypass Option
ii. Content : Al2O3 ≥ 95%
B B B B

iii. HRA≥85°, Flatness≤0.0003 mm, Parallelism≤0.015 mm No Hard Water Bypass (NHWP) means the valve can internally prevent raw water from
getting into service lines during regeneration.
iv. Acid and alkaline resistance: Ceramic has excellent stability against Inorganic acid and alkaline
at normal temperature.
A A A A

8 7 8 6 7 5 6 4 5 3 4 2 3 1 2 1
All Runxin valves can shut off the passage to outlet during regeneration except Model:
F79B, F82B, F92B.
High Strength Synthetic Fixed Disk

i. High Strength Synthetic material ensure the fixed disk resisting corrosion from many kinds acids
and strong alkalines except hot concentrated Nitric acid.
ii. The fixed disk is grinded to have same flatness as the ceramic moving disk to keep good and
reliable sealing. D
iii. Hermetic head faces construction has better ability to prevent damage from foreign substance
in the water. Varieties of Specifications injector
The ratio of injector draw to total flow rate is around 25% to 35%. Each tank has a
Partly Balance Construction specific injector matched.

For each softener valve, it adopts partly balance construction to prevent big torque as water
pressure increasing.

06 www.snowate.com www.snowate.com 07
Working Principle

Using hermetic head faces theory, Runxin valve is designed to integrate multi-ports round closely to one Controller
valve body. When the rotor rotates, some ports will be shut off and meanwhile some other ports will be
open, and thus the water will flow in and out this valve.

Signal Controller Actuator Moving Locating Controller


Disk Device
Construction
Runxin valve uses high-flatness moving disk and fixed disk to work as a valve. Fixed disk is fixed and moving disk is driven by
handle or motor to rotate closely over fixed disk. There are several blind via and through-holes on fixed disk and moving disk,
The controller gets signal from Timer, Meter or Water Quality Detecting Instrument, and then will initiate the motor
when moving disk stays on different positions of fixed disk, and then different flow passages will be formed:
to drive the actuator to rotate the moving disk, and when the moving disk rotates to the correct position, another
signal will be sent to the controller through the locating device, and the controller will stop the moving disk until
For softener valves
it finishes this step; When next new signal is received by the controller, the controller will drive the moving disk to
These positions are Service, Backwash, Brine & Slow Rinse, Brine Refill and Fast Rinse.
rotate to a new position and so on until all steps are finished and cycled.
For Filter valve
It has 3 positions: Service, Backwash and Fast Rinse.

8 7 6 5 4 3 2 1

Here, we take the F63 as example: E Water passes this part. No water passes this part. (Same as below)

D
6E 6D 6E 6D 6E 6D6E 6D 6D
6E 6E 6D6E 6D 6E 6E 6E 6E6D 6D6E
6D 6D 6D 6E 6E
6D 6E
6E6D 6D6E
6D 6D 6E 6E
6D 6E6D 6D6E 6D 6E 6E
6D 6E6D 6D
5A 5A - Blind hole
6F 6F 6F 6F 6F 6F
5B 5B - Passage to water inlet 6C 6C 6C 6F 6C 6C 6C 6F 6C 6F 6F 6F 6C 6F 6C 6C 6C 6F 6C 6F 6F
6F 6C 6F 6C 6C
6C 6F 6C 6F 6F 6C 6F 6C 6C 6F 6C 6F 6F 6C 6C 6C

4 3 2 1
6G 6G 6G 6G 6G 6G 6G 6G 6G 6G
C

5C 5C - Blind Hole
F
6A 6A 6A 6A 6A 6B 6B 6B 6B 6B 6B 6B 6B 6B 6B
6B 6B 6B 6B 6B 6B 6B 6A
6B 6B 6A 6B6B 6A 6A 6A
6A 6A 6A 6A 6A 6A 6A 6A 6A 6A 6B 6B
6A 6B 6A 6B 6A 6A 6A

6F - Passage to Brine Line connector


E Rotation Rotation Rotation Rotation Rotation
direction of moving disk direction of moving disk direction of moving disk direction of moving disk direction of moving disk
6E - Passage to Bottom Strainer
A

6E 6D 6D - Passage to Injector
D
8 7 6 5 4 3 2 1

6F 6C 6C - Passage to Water
6G
Outlet
6A
6B
C

6B - Passage to
Bottom Strainer

6G - Passage to Drain Outlet


B
6A - passage to Top Strainer

Service Position Backwash Position Brine&Slow Rinse Position Brine Refill Position Fast Rinse Position
A

4 3 2 1

08
08 www.snowate.com
www.snowate.com www.snowate.com
www.snowate.com 09
09
Applications & Industry

Runxin control valves (filter valves and softening valves) are core component during filtering and softening
system. They are widely used in various fields to guarantee efficient and easier water treatment.

Filtering & Softening Process Water Treatment

Industrial Fields Desalination (Pure and Ultra Pure Water)


Power station boiler make-up water, laboratory, electroplating plant,
Water filtering and softening for boiler, heat exchange equipment,
integrated circuit manufacturing, pharmaceutical preparations,
cooling system and RO system.
biochemistry, drinking water, cosmetics and other fields.

Agriculture Iron and manganese removal filtration


Mn Mn
Water filtering and softening for crops and flowers irrigation, Remove extra iron and manganese content in underground water
Mn
livestock drinking, vegetables and fruits washing. for domestic and industrial production use.

Residential Deaeration
Water filtering and softening for drinking, bathing, cooking, as
Deaeration for boiler water to prevent piping, water tank, and
well as for electric boilers, water heaters, underfloor heating and
other metal components from oxygen corrosion.
other installations.

Commercial Defluoridation
Pre-filtering and softening of RO system for drinking and Remove excess fluorine in underground water to protect people
domestic use. It can be used for swimming pool filtering. from fluorosis.

10 www.snowate.com www.snowate.com 11
Runxin Code System

53610 Special Application Control Valves

For code beginning with 1 are control valves for special applications, and for code
beginning with 4 are spare parts. The meaning of the first two digits refers to the
5 3 6 10 following chart.

Application Control Method Handle Type Or Maximum Flow Rate


Regeneration Type
For code beginning with 1

Code 11 13 15 17 18

Special Control valve for Control valve Control valve for Single valve with Single valve with
1 Special Application 0 Semi-Automatic 0 No control Type 10 10 m3/h
Applications fluoride removal for deaerator mixed bed system double tanks triple tanks

4 Spare Parts 1 Manual Control 1 Manual control,


metal handle
5 Filter 2 Automatic Control,
LCD Display 2 Manual control,
6 Softener, plastic handle
Downflow regeneration 3 Automatic control, Control Valve Spare Parts
LED Display 5 Automatic control,
7 Softener, time clock type
Upflow regeneration 4 Automatic Control,
Indicator Light 6 Automatic control, Code 41 42 43 44 45 46 47 48
8 Softener Display meter type
Downflow/Upflow
Special Bypass Tee Brine Online Disk Controller Disinfection Salt Shortage
regeneration 5 Automatic Control, 7 Automatic control, Monitoring
Applications Valve Valve Valve Filter Device Alarm Device
Digital Tube Display online monitoring Device
9 Floating Bed type
6 Automatic Control,
53610

WIFI Control

Examples For 17610 control valve


For 53610 control valve 17 means single valve with double tanks, 6 means meter type automatic softener valve,
5 means filter valve, 3 means LED display automatic control, 6 means meter type, 10 means water treatment capacity is 10 m3/h 10 means water treatment capacity is 10 m3/h,
That is, That is,
53610 means meter type automatic filter valve with water treatment capacity of 10 m3/h. 17610 means single valve with double tanks, meter type automatic softener valve with water treatment capacity of 10 m3/h.

12
12 www.snowate.com
www.snowate.com www.snowate.com
www.snowate.com 13
13
Manual Filter Control Valves

51106 (F56F1)
Model 51204C (F56AC) 51204K (F56K)
51206 (F56F2)
Structure & Performance Features Water Capacity 4 m3/h 4 m3/h 6 m3/h
● Hermetic head faces structure.
Handle Material Plastic handwheel Plastic Metal/Plastic
● No hard water bypass and can operate with pressure.
Mount Type Top Mount, Side control Top Mount Top Mount
● Manual regeneration. Handel could be rotated and assembled within 180°.
Inlet/Outlet 1"F 1"F 1"F Right in & Left Out

Drain 1"F 1"F 1"F


Applications
Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM
● Household Filter System (F56A/F56E/F56F).
Riser Pipe 1.05" OD 1.05" OD 1"D-GB
● Activated carbon filter or sand filter system for RO pretreatment system.
● Swimming Pool Filter System (N56D/F77BS). Available Tank Size 6"–12" 6"–12" 6"–14"

● N56D/F77BS can be used for Iron/Manganese Removal system if side Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa

mount adapter is installed upside down. Water Temperature 5–50 °C 5–50 °C 5–50 °C

Turbidity < 20 FTU < 20 FTU < 20 FTU

Media Sand / Activated Carbon Sand / Activated Carbon Sand / Activated Carbon

Popular Models

51102 (F56E1) 51104 (F56A1) 51110 (N56D1)


Model 51202C (F56EC) Model 51208 (F56L) 51215 (F77BS) 51240B (F112BS)
51202 (F56E2) 51204 (F56A2) 51210 (N56D2)

Water Capacity 2 m3/h 2 m3/h 4 m3/h Water Capacity 8 m3/h 10 m3/h 15 m3/h 40 m3/h

Handle Material Metal/Plastic Plastic handwheel Metal/Plastic Handle Material Plastic handwheel Metal/Plastic Plastic Handwheel Plastic handwheel

Mount Type Top Mount Top Mount, Side Control Top Mount Mount Type Top Mount Top/Side Mount Top/Side Mount Side Mount

Inlet/Outlet 1/2"F or 3/4"F 1/2"F or 3/4"F 1"F Inlet/Outlet 1.5"M 2"F 2"M DN65

Drain 1/2"F or 3/4"F 1/2"F or 3/4"F 1"F Drain 1.5"M 2"F 2"M DN65

Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM Base 4"-8UN 4"-8UN 4"-8UN -

Riser Pipe 1.05" OD 1.05" OD 1.05" OD Side Mount, Top and


Riser Pipe 1.25"D-GB / 1.66" OD 1.5"D-GB / 1.9" OD 1.5"D-GB / 1.9" OD
bottom DN80
Available Tank Size 6"–10" 6"–10" 6"–12" Available Tank Size 10" – 24" 10" – 24" 30" – 36" 36" – 48"
Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.2–0.6 MPa 0.2–0.6 MPa
Water Temperature 5–50 °C 5–50 °C 5–50 °C Water Temperature 5–50 °C 5–50 °C 5–50 °C 5–50 °C
Turbidity < 20 FTU < 20 FTU < 20 FTU Turbidity < 20 FTU < 20 FTU < 20 FTU < 20 FTU
Media Sand / Activated Carbon Sand / Activated Carbon Sand / Activated Carbon Sand / Activated Sand / Activated Sand / Activated Sand / Activated
Media Carbon Carbon Carbon Carbon

14 www.snowate.com www.snowate.com 15
Automatic Filter Control Valves

Structure & Performance Features


● LED display, indication of long time power off and data saved after power off (Saved for
three days).
53504 (F67C1) 53504S (F67B1)
● No hard water bypass in rising cycle. Model 53504B (F67G1) 53504C (F67I1)
53604 (F67C3) 53604S (F67B3)
● With signal output connector and two modes (b-01 or b-02) are optional.
Water Capacity 4 m3/h 4 m3/h 4 m3/h 4 m3/h
● Can set rinsing frequency F-00, realizing one time service and several times of backwash
and fast rinse. Mount Type Top Mount Top Mount Top Mount Top Mount

● With remote control connector to recieve passive signals. Inlet/Outlet 1"F 1"F 1"F 1"F
● With interlock connector to realize service simultaneously and rinse one by one. Drain 1"F 1"F 1"F 1"F
● Start rising by days or hours.
Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM
● N77, F95 and F111 have two valve cores, one is for controlling inlet water, the other is
for outlet water. Riser Pipe 1.05" OD 1.05" OD 1.05" OD 1.05" OD

● Time clock type or meter type is optional. Available Tank Size 6"–14" 6"–14" 6"–14" 6"–14"
● N77/F95 with RS-485 port are optional. Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa

Water Temperature 5–50 °C 5–50 °C 5–50 °C 5–50 °C


Applications Turbidity < 20 FTU < 20 FTU < 20 FTU < 20 FTU
● Residential Filter System (F71/F67). Media Sand / Activated Carbon Sand / Activated Carbon Sand / Activated Carbon Sand / Activated Carbon
● Activated carbon filter or sand filter system for RO pretreatment system. AC 100V – 240V / 50–60 AC 100V – 240V / AC 100V – 240V / 50–60 AC 100V – 240V / 50–60
Input Charge Hz 50–60 Hz Hz Hz
Transformer Output DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A

Popular Models

53502 (F71B1) 53506S (F67B1-A) 53508 (F134A1) 53510 (N75A1)


Model 53502B (F71G1) 56603 (F67M) Model 52504E (F67K)
53602 (F71B3) 53606S (F67B3-A) 53608 (F134A3) 53610 (N75A3)

Water Capacity 2 m3/h 2 m3/h 3 m3/h Water Capacity 4 m3/h 4 m3/h 8 m3/h 10 m3/h

Mount Type Top Mount Top Mount Top Mount Mount Type Top Mount Top Mount Top Mount Top Mount

Inlet/Outlet 3/4"M 3/4"M 3/4"M Inlet/Outlet 1"M 1"F 1.5"M 2"M

Drain 3/4"M 3/4"M 3/4"M Drain 1/2"M 1"F 1.5"M 2"M

Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM Base 2.5"-8NPSM 2.5"-8NPSM 4"-8UN 4"-8UN

Riser Pipe 1.05" OD 1.05" OD 1.05" OD Riser Pipe 1.05" OD 1"D-GB 1.25"D-GB or 1.66" OD 1.5"D-GB or 1.9" OD

Available Tank Size 6"–10" 6"–10" 6"–10" Available Tank Size 6"–14" 6"-14" 16"–18" 16"–21"

Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.2–0.6 MPa 0.15–0.6 MPa

Water Temperature 5–50 °C 5–50 °C 5–50 °C Water Temperature 5–50 °C 5–50 °C 5–50 °C 5–50 °C

Turbidity < 20 FTU < 20 FTU < 20 FTU Turbidity < 20 FTU < 20 FTU < 20 FTU < 20 FTU

Media Sand / Activated Carbon Sand / Activated Carbon Sand / Activated Carbon Media Sand / Activated Carbon Sand / Activated Carbon Sand / Activated Carbon Sand / Activated Carbon
AC 100V – 240V / 50–60 AC 100V – 240V / AC 100V – 240V / 50–60 AC 100V – 240V / 50–60
Input Charge AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz Input Charge Hz 50–60 Hz Hz Hz
Transformer Output DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A Transformer Output DC 12V/1.5A DC 12V/1.5A DC 24V/1.5A DC 24V/1.5A

16 www.snowate.com www.snowate.com 17
Manual Softening Control Valves

53510B (N75B1) 53515 (F99B1) Structure & Performance Features


Model 53518 (N77B1)
53610B (N75B3) 53615 (F99B3)
● Hermetic head faces structure.
Water Capacity 10 m3/h 15 m3/h 18 m3/h ● No hard water bypass and can operate with pressure.
Mount Type Top/Side Mount Top/Side Mount Top Mount ● Start regeneration by manual, and handle can be rotated 360° cycle.
Inlet/Outlet 2"M 2"M 2"M ● F64BC, F64AC could be side-operated.
Drain 2"M 2"M 2"M
Base 4"-8UN 4"-8UN 4"-8UN
Riser Pipe 1.5"D-GB or 1.9" OD 1.5"D-GB or 1.9" OD 1.5"D-GB or 1.9" OD
Applications
Available Tank Size 6"–21" 20"–30" 30"–36"
● Residential Softener System(F64A/F64AC/F64B/F64BC).
Working Pressure 0.15–0.6 MPa 0.2–0.6 MPa 0.2–0.6 MPa
● Softener system for RO.
Water Temperature 5–50 °C 5–50 °C 5–50 °C
● Boiler softener system; ion exchange units.
Turbidity < 20 FTU < 20 FTU < 20 FTU
Media Sand / Activated Carbon Sand / Activated Carbon Sand / Activated Carbon
Input Charge AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz
Transformer Output DC 24V/1.5A DC 24V/1.5A DC 24V/1.5A

Popular Models

53520 (F95B1) 53520T (F111B1) 53540B (F112B1) 53550 (F96B1)


Model
53620 (F95B3) 53620T (F111B3) 53640B (F112B3) 53650 (F96B3)
Model 61202 (F64B) 61202C (F64BC)
Water Capacity 21.6 m3/h 20 m3/h 40 m3/h 50 m3/h
Water Capacity 2 m3/h 2 m3/h
Mount Type Side Mount Top Mount Side Mount Side Mount
Regeneration Type Downflow Downflow
Inlet/Outlet 2"M 2"M DN65 DN80
Handle material Plastic handwheel Plastic handwheel
Drain 2"M 2"M DN65 DN80
Mount Type Top Mount Top Mount
Base - 4"-8UN - -
Inlet/Outlet 3/4"F 3/4"F
Side mount top and Side mount, top and Side mount, top and
Riser Pipe 2"D-GB
bottom distributor 2"M bottom distributor DN80 bottom distributor DN100 Drain 1/2"M 1/2"M
Available Tank Size 30"–36" 30"–36" 36"–48" 36"–48" Brine Tank
3/8"M 3/8"M
Connector
Working Pressure 0.2–0.6 MPa 0.2–0.6 MPa 0.2–0.6 MPa 0.2–0.6 MPa
Base 2.5"-8NPSM 2.5"-8NPSM
Water Temperature 5–50 °C 5–50 °C 5–50 °C 5–50 °C
Riser Pipe 1.05" OD 1.05" OD
Turbidity < 20 FTU < 20 FTU < 20 FTU < 20 FTU
Available Tank Size 6"–10" 6"–10"
Media Sand / Activated Carbon Sand / Activated Carbon Sand / Activated Carbon Sand / Activated Carbon
Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa
AC 100V – 240V / 50–60 AC 100V – 240V / AC 100V – 240V / 50–60 AC 100V – 240V / 50–60
Input Charge Hz 50–60 Hz Hz Hz Water Temperature 5–50 °C 5–50 °C
Transformer Output DC 24V/1.5A DC 24V/1.5A DC 24V/4.0A DC 24V/4.0A Turbidity < 5 FTU < 5 FTU

18 www.snowate.com www.snowate.com 19
Automatic Softening Control Valves

61104 (F64A1)
Model 61204C (F64AC) 61206 (N64F) Structure & Performance Features
61204 (F64A2)

Water Capacity 4.5 m3/h 4.5 m3/h 8 m3/h ● LED display, long time power off indication and data will be saved for three days after power off.

Regeneration Type Downflow Downflow Downflow ● No hard water bypass in regeneration cycle (except F92 and F130).

Handle material Metal/Plastic handwheel Plastic handwheel Plastic handwheel ● With signal output connector, remote handling connector which can receive passive signal.
Mount Type Top Mount Top Mount, Side control Top Mount ● With interlock connector which can realize service simultaneously and regeneration one by one.
Inlet/Outlet 1"F 1"F 1.5"M ● N77, F95, F111 and F99 adopt ball valve for brine drawing and refill.
Drain 1/2"M 1/2"M 3/4"M
● Time clock regeneration option: by days or by hours; Meter valve regeneration option: Meter Delayed (A-01),
Brine Tank Connector 3/8"M 3/8"M 1/2"M Meter Immediate (A-02), Intelligent Meter Delayed (A-03), intelligent Meter Immediate (A-04).

Base 2.5"-8NPSM 2.5"-8NPSM 4"-8UN ● Up-flow control valve can set interval backwash times F-00, which can realize several times service and one time backwash.
Riser Pipe 1.05" OD 1.05" OD 1.25"D-GB ● N77, F95 and F111 have two valve cores, one is for controlling inlet water and brine drawing, another is for outlet water.
Available Tank Size 6"–16" 6"–16" 6"–21" ● N77 and F95 with RS-485 port are optional.
Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa

Water Temperature 5–50 °C 5–50 °C 5–50 °C

Turbidity < 5 FTU < 5 FTU < 5 FTU

Applications

● Residential Softener Systems (F63/F65/F68/F69).


● Softener for RO pretreatment System.
● Boiler Softening System, lon exchange system.

Model 61210 (N64D) 61215 (F77AS) 61240B (F112AS)

Water Capacity 10 m3/h 15 m3/h 40 m3/h

Regeneration Type Downflow Downflow Downflow

Handle material Plastic handwheel Plastic handwheel Plastic handwheel

Mount Type Top/Side Mount Top/Side Mount Side Mount Notes


Inlet/Outlet 2"M 2"M DN65 ● The model with a “S" means the valve with manual operation function.
2"M, connect 1.5"M current ● N77,F95,F111 brine refilled while service, brine refilling controlled by
Drain 1"M
limiting parts
DN65
electronic ball valve.
Brine Tank Connector 1/2"M 3/4"M 3/4"M
● F63, F65, F68 and F69 have a variety of appearances optional.
Base 4"-8UN 4"-8UN -
Side mount, top and bottom ● N74B is optional which can be top or side-mounted.
Riser Pipe 1.5"D-GB 1.5"D-GB or 1.9"OD
distributor DN80
Available Tank Size 6"–21" 30"–36" 40"–48"

Working Pressure 0.15–0.6 MPa 0.2–0.6 MPa 0.2–0.6 MPa

Water Temperature 5–50 °C 5–50 °C 5–50 °C

Turbidity < 5 FTU < 2 FTU < 5 FTU

20 www.snowate.com www.snowate.com 21
63502 (F65B1) 63502B (F65G1) 73502 (F69A1) 63504B (F63G1) 63504C (F63I1) 63504S (F63B1)
Model Model
63602 (F65B3) 63602B (F65G3) 73602 (F69A3) 63604B (F63G3) 63604C (F63I3) 63604S (F63B3)
Water Capacity 2 m3/h 2 m3/h 2 m3/h Water Capacity 4 m3/h 4 m3/h 4 m3/h

Running Model Time Clock / Meter Time Clock / Meter Time Clock / Meter Running Model Time Clock / Meter Time Clock / Meter Time Clock / Meter
Regeneration Type Downflow Downflow Upflow Regeneration Type Downflow Downflow Downflow
Mount Type Top Mount Top Mount Top Mount Mount Type Top Mount Side Mount Top Mount
Inlet/Outlet 3/4"F 3/4"F 3/4"F Inlet/Outlet 1"M 1"M 1"M
Drain 1/2"M 1/2"M 1/2"M Drain 1/2"M 1/2"M 1/2"M
Brine Tank Brine Tank
3/8"M 3/8"M 3/8"M 3/8"M 3/8"M 3/8"M
Connector Connector
Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM
Riser Pipe 1.05" OD 1.05" OD 1.05" OD Riser Pipe 1.05" OD 1.05" OD 1.05" OD
Available Tank Size 6"–10" 6"–10" 6"–10" Available Tank Size 6"–14" 6"–14" 6"–14"
Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa
Water Temperature 5–45 °C 5–45 °C 5–45 °C Water Temperature 5–50 °C 5–50 °C 5–50 °C
Turbidity < 5 FTU < 5 FTU < 2 FTU Turbidity < 5 FTU < 5 FTU < 5 FTU
Input Charge AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz Input Charge AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz
Output Charge DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A Output Charge DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A

73502B (F69G1) 63503 (F117A1) 63504 (F63C1) 73504 (F68C1) 73504B (F68G1) 73504S (F68A1)
Model Model
73602B (F69G3) 63603 (F117A3) 63604 (F63C3) 73604 (F68C3) 73604B (F68G3) 73604S (F68A3)
Water Capacity 2 m3/h 2 m3/h 4 m3/h Water Capacity 4 m3/h 4 m3/h 4 m3/h

Running Model Time Clock / Meter Time Clock / Meter Time Clock / Meter Running Model Time Clock / Meter Time Clock / Meter Time Clock / Meter
Regeneration Type Upflow Downflow Downflow Regeneration Type Upflow Upflow Upflow
Mount Type Top Mount Top Mount Top Mount Mount Type Top Mount Top Mount Top Mount with handwheel
Inlet/Outlet 3/4"F 3/4"F 1"M Inlet/Outlet 1"M 1"M 1"M
Drain 1/2"M 3/4"M 1/2"M Drain 1/2"M 1/2"M 1/2"M
Brine Tank Brine Tank
3/8"M 3/8"M 3/8"M 3/8"M 3/8"M 3/8"M
Connector Connector
Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM
Riser Pipe 1.05" OD 1.05" OD 1.05" OD Riser Pipe 1.05" OD 1.05" OD 1.05" OD
Available Tank Size 6"–10" 6"–10" 6"–14" Available Tank Size 6"–14" 6"–14" 6"–14"
Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa
Water Temperature 5–50 °C 5–50 °C 5–50 °C Water Temperature 5–50 °C 5–50 °C 5–50 °C
Turbidity < 2 FTU < 5 FTU < 5 FTU Turbidity < 2 FTU < 2 FTU < 2 FTU
Input Charge AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz Input Charge AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz
Output Charge DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A Output Charge DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A

22 www.snowate.com www.snowate.com 23
63505 (F116A1) 73505 (F92A1) 63515 (F99A1) 73515 (F99D1) 63518 (N77A1) 63520 (F95A1)
Model F116E3 F130A3 Model
63605 (F116A3) 73605 (F92A3) 63615 (F99A3) 73615 (F99D3) 63618 (N77A3) 63620 (F95A3)
Water Capacity 4 m3/h 5 m3/h 5 m3/h 4.7 m3/h Water Capacity 15 m3/h 15 m3/h 18 m3/h 21.6 m3/h
Running Model Time Clock / Meter Meter Meter Time Clock / Meter Running Model Time Clock / Meter Time Clock / Meter Time Clock / Meter Time Clock / Meter

Regeneration Type Downflow Downflow Downflow Upflow Regeneration Type Downflow Upflow Downflow Downflow

Mount Type Top Mount Top Mount Top Mount Top Mount Mount Type Top/Side Mount Top/Side Mount Top/Side Mount Side Mount

Inlet/Outlet 1"M 1"M 1"M 1"M Inlet/Outlet 2"M 2"M 2"M 2"M

Drain 3/4"M 3/4"M NPT 3/4" 3/4"M Drain 1.5"M 1.5"M 1.5"M 1.5"M

Brine Tank Connector 3/8"M 3/8"M 3/8"M 3/8"M Brine Tank Connector 3/4"M 3/4"M 3/4"M 3/4"M

Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM Base 4"-8UN 4"-8UN 4"-8UN -


Riser Pipe 1.05" OD 1.05" OD 1"D-GB 1"D-GB Side mount, top and
Riser Pipe 1.5"D-GB or 1.9" OD 1.5"D-GB or 1.9" OD 1.5"D-GB or 1.9" OD
bottom distributor 2"M
Available Tank Size 6"–14" 10"–20" 7"–22" 9"–16"
Available Tank Size 30" 30" 30"–36" 36"–40"
Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa
Working Pressure 0.2–0.6 MPa 0.2–0.6 MPa 0.2–0.6 MPa 0.2–0.6 MPa
Water Temperature 5–50 °C 5–50 °C 5–50 °C 5–50 °C
Water Temperature 5–50 °C 5–50 °C 5–50 °C 5–50 °C
Turbidity < 5 FTU < 5 FTU < 5 FTU < 2 FTU
Turbidity < 5 FTU < 2 FTU < 5 FTU < 5 FTU
AC 100V – 240V / 50–60 AC 100V – 240V / 50–60 AC 100V – 240V / 50–60 AC 100V – 240V / 50–60
Input Charge AC 100V – 240V / AC 100V – 240V / 50–60 AC 100V – 240V / 50–60 AC 100V – 240V / 50–60
Hz Hz Hz Hz Input Charge 50–60 Hz Hz Hz Hz
Output Charge DC 12V/1.5A DC 12V/1.5A DC 12V/2A DC 12V/2.0A
Output Charge DC 24V/1.5A DC 24V/1.5A DC 24V/1.5A DC 24V/1.5A

63508 (F133A1) 63510 (N74A1) 63510B (N74B1) 63520T (F111A1) 73520 (F95D1) 63540B (F112A1) 63550 (F96A1)
Model 73605E (F92E3) Model
63608 (F133A3) 63610 (N74A3) 63610B (N74B3) 63620T (F111A3) 73620 (F95D3) 63640B (F112A3) 63650 (F96A3)
Water Capacity 5 m3/h 8 m3/h 10 m3/h 10 m3/h Water Capacity 21.1 m3/h 21.6 m3/h 40 m3/h 50 m3/h
Running Model Meter Time Clock / Meter Time Clock / Meter Time Clock / Meter Running Model Time Clock / Meter Time Clock / Meter Time Clock / Meter Time Clock / Meter
Regeneration Type Upflow Downflow Downflow Downflow Regeneration Type Downflow Upflow Downflow Downflow

Mount Type Top Mount Top Mount Top Mount Top/Side Mount Mount Type Top Mount Side Mount Side Mount Side Mount
Inlet/Outlet 2"M 2"M DN65 DN80
Inlet/Outlet 1"M 1.5"M 2"M 2"M
Drain 1.5"M 1.5"M DN65 DN80
Drain NPT 3/4" 3/4"M 1"M 1"M
Brine Tank Connector 3/4"M 3/4"M 3/4"M 3/4"M
Brine Tank Connector 3/8"M 1/2"M 1/2"M 1/2"M
Base 4"-8UN - - -
Base 2.5"-8NPSM 4"-8UN 4"-8UN 4"-8UN Side mount, top and Side mount, top and Side mount, top and
Riser Pipe 2"D-GB
bottom distributor 2"M bottom distributor DN80 bottom distributor DN100
Riser Pipe 1"D-GB 1.25"D-GB or 1.66" OD 1.5"D-GB or 1.9" OD 1.5"D-GB or 1.9" OD
Available Tank Size 36"–40" 36"–40" 40"–48" 60"–63"
Available Tank Size 7"–22" 16"–18" 20"–21" 20"–21"
Working Pressure 0.2–0.6 MPa 0.2–0.6 MPa 0.2–0.6 MPa 0.2–0.6 MPa
Working Pressure 0.15–0.6 MPa 0.2–0.6 MPa 0.2–0.6 MPa 0.2–0.6 MPa
Water Temperature 5–50 °C 5–50 °C 5–50 °C 5–50 °C
Water Temperature 5–50 °C 5–50 °C 5–45 °C 5–45 °C
Turbidity < 5 FTU < 2 FTU < 5 FTU < 5 FTU
Turbidity < 2 FTU < 5 FTU < 5 FTU < 5 FTU AC 100V – 240V / AC 100V – 240V / AC 100V – 240V / AC 100V – 240V /
Input Charge 50–60 Hz 50–60 Hz 50–60 Hz 50–60 Hz
AC 100V – 240V / 50–60 AC 100V – 240V / 50–60 AC 100V – 240V / 50–60 AC 100V – 240V /
Input Charge Hz Hz Hz 50–60 Hz
Output Charge DC 24V/1.5A DC 24V/1.5A DC 24V/4.0A DC 24V/4.0A
Output Charge DC 12V/1.5A DC 24V/1.5A DC 24V/1.5A DC 24V/1.5A

24 www.snowate.com www.snowate.com 25
Continuous Water Supply Control Valves

One in Service One Standby – One Valve on Duplex Tank


To satisfy markets continuous water supply requirements, Runxin develop
17603 17603 (F73) 17606 (F98A) 17606T (F137) 17610 (F88A) 17610T (F135A)
the first control valve, which can control two tanks one time to achieve one
in service and one standby and guarantee continuous water supply. Water Capacity 3.5 m3/h 6 m3/h 6 m3/h 10 m3/h 10 m3/h

This system contains one control valve and two tanks, it can achieve Regeneration Type Upflow/Downflow Upflow Downflow Upflow Donwflow
downflow or upflow regeneration through switch program. Besides, it Mount Type Top Mount Side Mount Top Mount Side Mount Top Mount
adopts top or side mount method according to different output and tank
Inlet/Outlet 1"M 1"M 1"M 1.5"M 1.5"M
structure.
Drain 1/2"M 3/4"M 3/4"M 1"M 3/4"M
This structure can achieve max. output 3.5 m3/h, 6 m3/h, 10 m3/h.
Brine Tank Connector 3/8"M 1/2"M 1/2"M 1/2"M 1/2"M

Base 2.5"-8NPSM - 4"-8UN - 4"-8UN


Side mount, Side mount,
1.5"D-GB 1.5"D-GB or
Riser Pipe 1.05" OD top and bottom top and bottom
Technical Performance (32 mm OD) 1.9"OD
distributor 1"M distributor 1.5"M
Available Tank Size 12"-14" 20"–21" 16"–24" 20"–30" 20"–30"
Item Requirements
Turbidity < 2 FTU or < 5 FTU < 2 FTU < 5 FTU < 2 FTU < 5 FTU
Water Pressure 0.2–0.6 MPa
Working Condition
Water Temperature 5–50 °C

Environment Temperature 5–50 °C One in Service One Standby – Floating Bed


Working Environment Relative Humidity ≤95% (25 °C)

Electrical Facility AC 100V – 240V / 50–60 Hz

Water Turbidity Upflow regeneration < 2FTU | Downflow regeneration < 5FTU


First Grade Na+:
Water Hardness
93610/93606 < 15 mmol/L | 17610/17606 < 6.5 mmol/L
Inlet Water Quality Free Chlorine < 0.1 mg/L
Model 93606 (F98C) 93610 (F88C)
Iron2+ < 0.3 mg/L
Water Capacity 6 m3/h 10 m3/h
CODMn < 2 mg/L (O2)
Regeneration Type Upflow Upflow
Mount Type Side Mount Side Mount
Inlet/Outlet 1"M 1.5"M
Drain 3/4"M 1"M
Notes
Brine Tank Connector 1/2"M 1/2"M
● First grade Na refers to First grade NA ion exchanger Base - -

● When the turbidity exceeds the working condition, a filter should be installed on the inlet of control valves. Riser Pipe Side mount, top and bottom distributor 1"M Side mount, top and bottom distributor 1.5"M

● When the water hardness exceeds the working condition, the hardness of treated water can not meet the Available Tank Size 14"–16" 20"–21"
needed requirements (for example 0.03 mmol/L for boil water), you should adopt secondary softening. Turbidity < 2 FTU < 2 FTU

26 www.snowate.com www.snowate.com 27
One in service and one standby fixed bed system Control valve for floating bed system
17610/17606 93610/93606

Brine Line
Brine Line Brine Line
Brine Line
Drain
Drain Drain
Drain Connector
Connector
Brine Line Connector
Connector
Brine Line Brine Line
Brine Line
Connector
Connector Connector
Inlet
Inlet Outlet
Outlet Inlet
Inlet Outlet
Outlet Connector
Inlet Inlet
Brine Line
Brine Line
Connector
Connector
Brine Line
Brine Line
Connector Inlet Inlet
Inlet Inlet Connector
Inlet Inlet
Drain Outlet Outlet Outlet Outlet
Tank
TankU1
U1 Drain Tank
TankU2
U2 Tank
TankU1
U1 Drain
Drain Tank
TankU2
U2 Tank Tank
U2 U2 Tank Tank
U1 U1 Tank Tank
U2 U2 Tank Tank
U1 U1
U2 U2 Drain Drain Inlet Inlet
OutletOutlet OutletOutlet Drain Inlet Inlet
Inlet
Inlet Brine
Brine
Line
Line
Outlet
Outlet
Connector
Connector Inlet
Inlet Brine
Brine
Line
Line
Connector Outlet
Outlet
Connector TankTank TankTank
U1 U1 TankTank
U2 U2 Drain TankTank
U1 U1
DrainDrain
Outlet DrainDrain
Outlet Outlet
TankTank
U2 U2 TankTank
U1 U1 TankTank
Outlet
U2 U2 TankTank
U1 U1
TankU1
Tank U1 DrainDrain TankU2
Tank U2 TankU1
Tank U1 DrainDrain TankU2
Tank U2 DrainDrain DrainDrain
Brine Line Brine Line
Inlet Inlet Brine Line
Outlet
Connector
Connector Outlet Inlet Inlet Brine Line
Outlet
Connector
Connector Outlet

Tank U2 in service and Tank U1 in standby TankTank Tank U1 in service and Tank U2 in standby Tank U2 in service and Tank U1 in Brine & Slow Rinse
TankTank
U1 U1 TankTank
U2 U2 TankU1
U1inU1
service and Tank U2 in Brine & Slow
TankTank
U2 U2
Brine Brine
Line Line Rinse (UpflowBrine
regeneration)
Brine
Line Line
Connector
Connector Connector
Connector

Drain
Drain Drain
Drain
Inlet
Inlet Outlet
Outlet Inlet
Inlet Outlet
Outlet
Brine Line
Brine Line Brine Line
Brine Line
Connector
Connector Connector
Connector
Brine Line
Brine Line Brine Line
Brine Line
Tank
TankU1
U1 Drain
Drain Tank
TankU2
U2 Tank
TankU1
U1 Drain
Drain Tank
TankU2
U2 Connector
Connector Connector
Connector
Inlet
Inlet Brine
Brine
Line
Line
Connector Outlet
Outlet
Connector Inlet
Inlet Brine
Brine
Line
Line
Connector Outlet
Outlet
Connector Brine Line Inlet Inlet
Brine Line
Connector
Connector
Brine Line Inlet Inlet
Brine Line
Connector
Connector
Inlet Inlet Inlet Inlet
Outlet Outlet Outlet Outlet
Tank Tank
U2 U2 Tank Tank
U1 U1 Tank Tank
U2 U2 Tank Tank
U1 U1
U2 U2 Drain Drain Inlet Inlet U2 U2 Drain Drain Inlet Inlet
TankU1
U1 DrainDrain TankU2
U2 TankU1
U1 DrainDrain TankU2
U2 OutletOutlet OutletOutlet
Tank Tank Tank Tank TankTank TankTank
U1 U1 TankTank TankTank
U1 U1
Brine Line Brine Line DrainDrain DrainDrain
Inlet Inlet Brine Line
Outlet
Connector
Connector Outlet Inlet Inlet Brine Line
Outlet
Connector
Connector Outlet Outlet Outlet Outlet Outlet
TankTank
U2 U2 TankTank
U1 U1 TankTank
U2 U2 TankTank
U1 U1
DrainDrain DrainDrain
TankTank
U1 U1 TankTank
U2 U2 TankTank
U1 U1 TankTank
U2 U2
Brine Brine
Line Line Brine Brine
Line Line
Connector
Connector Connector
Connector

Tank U2 in Service and Tank U1 in fast rinse Tank U1 in service and Tank U2 in brine infill Tank U1 in Service and Tank U2 in fast rinse Tank U2 in service and Tank U1 in brine infill

Drain
Drain Drain
Drain
Inlet
Inlet Outlet
Outlet Inlet
Inlet Outlet
Outlet

Tank
TankU1
U1 Drain
Drain Tank
TankU2
U2 Tank
TankU1
U1 Drain
Drain Tank
TankU2
U2
Brine
Brine
Line
Line Brine Line
Brine Line Brine Line
Brine Line
Inlet
Inlet Brine
Brine
Line
Line
Outlet
Outlet
Connector
Connector
Inlet
Inlet Outlet
Outlet
Connector
Connector Connector
Connector Connector
Connector
Brine Line
Brine Line Brine Line
Brine Line
Connector
Connector Connector
Connector

TankU1
Tank U1 DrainDrain TankU2
Tank U2 Brine Line Inlet Inlet
Brine Line Inlet Inlet
Brine Line
Brine Line
TankU1
Tank U1 DrainDrain TankU2
Tank U2 Connector
Connector
Inlet Inlet
Connector
Connector
Inlet Inlet
Brine Line
Inlet Inlet Brine
Brine Line
Line
OutletOutlet Inlet Inlet Brine Line
Outlet
Connector Outlet Outlet Outlet
Tank Tank
U1 U1 Outlet Outlet
Tank Tank
U1 U1
Connector
Connector Connector
Tank Tank
U2 U2 Tank Tank
U2 U2
U2 U2 Drain Drain Inlet Inlet U2 U2 Drain Drain Inlet Inlet
OutletOutlet OutletOutlet
TankTank TankTank
U1 U1 TankTank TankTank
U1 U1
DrainDrain
Outlet DrainDrain
Outlet
TankTank
U1 U1 TankTank
U2 U2 TankTank
U1 U1 TankTank
U2 U2 TankTank
Outlet
U2 U2 TankTank
U1 U1 TankTank
Outlet
U2 U2 TankTank
U1 U1
Brine Brine
Line Line Brine Brine
Line Line
Connector
Connector Connector
Connector DrainDrain DrainDrain

Tank U1 in Service and Tank U2 in Backwash Tank U1 in Service and Tank U2 in Standby Tank U2 in Service and Tank U1 in Setting Bed Tank U2 in Service and Tank U1 in Standby

2828www.snowate.com
www.snowate.com www.snowate.com2929
www.snowate.com
One in Service One Standby – Two Valve and Two Tank Two in Service One Standby

F92A3 F92A3
5–6 m3/h ● One valve controls three tanks, two tanks supply with softened water in series, the other tank standby to achieve water supply continuously.

● Suitable for 5-6 m3/h Continuous Water Supplying ● When service finishes, the first grade in series tums to regenerate, the second grade tums to the first grade and supplies with softened water
together with the standby tank as the second grade in series, which greatly improves the resin efficiency, saves water and salt.
● Two F92A3/F130A3 and DN25 Three-way Electronic Bal
● Regeneration tank keeps standby after switch and starts fast rinse before service.
Valve (Four Core Plug)
● Only need one brine tank. Inlet
● Two F92A3/F130A3 are interlocked as one system, and set Outlet
C-02 (a connection for one in service one standby softening system) ● It adopts hermetic head faces structure with ceramic sealing, reliable and duration.

● Up-flow or down-flow regeneration is optional by program.

● Raw water or softened water for regeneration is optional by changing the moving disk.

● Remove one tank to make the system as one in service one standby system.
10–20 m3/h
● There is always two tanks in service in series which could treat the raw water with high
3
● Suitable for 10-20 m /h Continuous Water Supplying hardness. It has backwash function, which could be used in high turbidity application
which floating bed system can' t be used.
● Two N74A3/F99A3/N77A3/F95A3/F111A3 and F80
● Two valves are interlocked as one system, and set the system to ● Suitable for treat high hardness water and continuous water supplying application Right Tank
A-02 and b-01; Connect the signal output connector with the Middle tank
control wire of F80. left tank
● When the flow of working valve reduces to 0, the control valve
regenerates F80 switches by the signal outlet connector controlling,
the other valve turns to service.
● If the other valve is in regeneration, because of the function of interlock,
the working valve still in service.

1# Valve 18604A (F118A)


Main Control Board Model 18601B (F120B)
NC 18604B (F118B)
Blue COM
Black
1# Water Capacity 4 m3/h 1.5 m3/h
NO F80 Valve
Main Control Board
Running Model Meter Meter
Interlock Power cord
2# Valve Regeneration Type Downflow/Upflow Downflow/Upflow
Cablel
Main Control Board NC Mount Type Top Mount Top Mount
Blue COM
Black
2# -24DC
Inlet/Outlet G1" G3/4"
NO
+24VDC
Drain NPT 3/4" NPT 3/4"
Brine Tank Connector G3/8" G3/8"
Base 3 × 2.5"-8NPSM 3 × 2.5"-8NPSM
Riser Pipe 3 × 1.05" OD 3 × 1.05" OD
40–50 m3/h
Available Tank Size 10"–18" 10"–12"
● Suitable for 40–50 m3/h Continuous Water Supplying Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa
● Two F112A3/F96A3 and Two DN25 Electronic Ball Valves
Water Temperature 5–50 °C 5–50 °C
● Two valves are connected to signal line of one in service and one
standby system (interlock wire), and set the system to C-02 (One Downflow < 5 FTU Downflow < 5 FTU
Turbidity
in Service One Standby System). Upflow < 2 FTU Upflow < 2 FTU
● Ordinary F112A3/F96A3 needs to replace brine draw copper tube Input Charge AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz
and install DN25 ball valve with it.
Transformer Output DC 12V/2A DC 12V/2A
● Continuous water supplying, one valve in service, the other valve
standby.

30
30 www.snowate.com
www.snowate.com www.snowate.com
www.snowate.com 31
31
Softener Flow Chart P Series
Inlet Inlet Inlet
Outlet Outlet Outlet
Softening
Inlet Inlet Inlet
Outlet Outlet Outlet Structure & Performance Features
● Locate by optocoupler, more stable performance. F63P, F67P and F68P adopt the same locating board, while F65P, F69P
and F71P use the same locating board. They all use the same main control board.

● Hermetic head faces structure, no hard water bypass during regeneration cycle.

● When power on, program run one cycle then locate at the previous position.
Right Tank Right Tank Right Tank
Middle tank Middle tank Middle tank ● Cheaper and simpler.
left tank left tank left tank Right Tank
Right Tank Right Tank ● Indicator display
Middle tank Middle tank Middle tank
left tank left tank left tank

Left tank + middle tank in serial service, Middle tank + right tank in serial service, Right tank + left tank in serial service, 64502 (F65P1) 74502 (F69P1)
right tank regeneration and standby left tank regeneration and standby middle tank regeneration and standby Model 54502 (F71P1) 74502Y (F69P1Y)
64602 (F65P3) 74602 (F69P3)
3
Water Capacity 2 m /h 2 m3/h 2 m3/h 2 m3/h
Running Model Time Clock Time Clock / Meter Time Clock / Meter Time Clock
Regeneration It takes left tank and middle tank in serial service and right tank regeneration as sample. Regeneration Type - Downflow Upflow Upflow
Mount Type Top Mount Top Mount Top Mount Top Mount
Inlet/Outlet 3/4"M 3/4"M 3/4"F 3/4"M
Left tank + middle tank in serial service, Left tank + middle tank in serial service, Left tank + middle tank in serial service,
right tank backwash right tank upflow brine draw right tank downflow brine draw
Drain 3/4"M 1/2"M 1/2"M 1/2"M
Brine Tank Connector - 3/8"M 3/8"M 3/8"M
Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM
Riser Pipe 1.05" OD 1.05" OD 1.05" OD 1.05" OD
Inlet Inlet Inlet
Outlet Outlet Outlet Available Tank Size 6"–10" 6"–10" 6"–10" 6"–10"
Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa
Inlet Inlet Inlet
Outlet Outlet Outlet Water Temperature 5–50 °C 5–50 °C 5–50 °C 5–50 °C
Turbidity < 20 FTU < 5 FTU < 2 FTU < 2 FTU
AC 100V – 240V / AC 100V – 240V / 50–60 AC 100V – 240V / AC 100V – 240V /
Input Charge 50–60 Hz Hz 50–60 Hz 50–60 Hz
Output Charge DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A

Right Tank Right Tank Right Tank


Middle tank Middle tank Middle tank
left tank Right Tank left tank Right Tank left tank Right Tank
Middle tank Middle tank Middle tank
Inlet Inlet Inlet 64504 (F63P1) 74504 (F68P1)
left tank left tank left tank Outlet Model 54504 (F67P1) 74504Y (F68P1Y)
Outlet Outlet 64604 (F63P3) 74604 (F68P3)
3
Inlet Inlet Inlet Water Capacity 4 m /h 4 m3/h 4 m3/h 4 m3/h
Outlet Outlet Outlet Running Model Time Clock Time Clock / Meter Time Clock / Meter Time Clock
Regeneration Type - Downflow Upflow Upflow
Mount Type Top Mount Top Mount Top Mount Top Mount
Inlet/Outlet 1"F 1"M 1"M 1"M
Drain 1"F 1/2"M 1/2"M 1/2"M
Brine Tank Connector - 3/8"M 3/8"M 3/8"M
Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM
Right Tank Right Tank Right Tank Riser Pipe 1.05" OD 1.05" OD 1.05" OD 1.05" OD
Middle tank Middle tank Middle tank
Available Tank Size 6"–14" 6"–14" 6"–14" 6"–14"
left tank Right Tank left tank left tank Right Tank
Right Tank Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa
Middle tank Middle tank Middle tank
Water Temperature 5–50 °C 5–50 °C 5–50 °C 5–50 °C
left tank left tank left tank
Left tank + middle tank in serial service, Left tank + middle tank in serial service, Left tank + middle tank in serial service, Turbidity < 20 FTU < 5 FTU < 2 FTU < 2 FTU
right tank fast rinse right tank standby right tank brine refill AC 100V – 240V / AC 100V – 240V / 50–60 AC 100V – 240V / AC 100V – 240V /
Input Charge 50–60 Hz Hz 50–60 Hz 50–60 Hz
Output Charge DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A

32 www.snowate.com www.snowate.com 33
Q Series Floating Bed

Structure & Performance Features Application Structure & Performance Features


● Hermetic head faces structure (F112 has piston structure)
● Integrate main board and display board on one board. ● Residential softener or filter system.
● For F88, F98 valve, one valve on twin tanks, one in service, the other standby.
● Four digital display. ● Boiler softener, lon-exchange equipment. ● F83, F77CS and F112CS adopt hard water for regeneration, others adopt soft water for regeneration.
● With interlock connector and signal output connector. ● Adopt the working process: up-flow service – brine draw – brine refill – fast rinse.
● Parameters will be saved after power off. ● Suitable for high hardness (less than 15 mmo/L) water treatment applications.

55502 (F71Q1) 75502 (F69Q1) 65503 (F117Q1) 55504 (F67Q1) 93504 (F83A1)
Model Model 93606 (F98C) 93610 (F88C) 91215 (F77CS)
55602 (F71Q3) 75602 (F69Q3) 65603 (F117Q3) 55604 (F67Q3) 93604 (F83A3)
Water Capacity 2 m3/h 2 m3/h 2 m3/h 4 m3/h Water Capacity 4 m3/h 6 m3/h 10 m3/h 15 m3/h
Running Model Time Clock / Meter Time Clock / Meter Time Clock / Meter Time Clock / Meter Running Model Time Clock / Meter Meter Meter Manual Softener
Regeneration Type - Upflow Downflow - Regeneration Type Upflow Upflow Upflow Upflow
Mount Type Top Mount Top Mount Top Mount Top Mount Mount Type Top Mount Side Mount Side Mount Top/Side Mount
Inlet/Outlet 3/4"M 3/4"M 3/4"F 1"F Inlet/Outlet 1"M 1"M 1.5"M 2"M
Drain 3/4"M 3/4"NPT 3/4"NPT 1"F Drain 1/2"M 3/4"M 1"M 2"M
Brine Tank Connector - 3/8"M 3/8"M - Brine Tank Connector 3/8"M 1/2"M 1/2"M 3/4"M
Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM Base 2.5"-8NPSM - - 4"-8UN
Riser Pipe 1.05" OD 1.05" OD 1.05" OD 1.05" OD
Riser Pipe 1.05" OD
Side mount, top and Side mount, top and bottom
1.5"D-GB
Available Tank Size 6"–10" 6"–10" 6"–10" 6"–10" bottom distributor 1"M distributor 1.5"M
Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa Available Tank Size 10"–14" 14"–16" 20"–21" 20"–30"
Water Temperature 5–50 °C 5–50 °C 5–50 °C 5–45 °C Working Pressure 0.15–0.6 MPa 0.2–0.6 MPa 0.2–0.6 MPa 0.2–0.6 MPa
Turbidity < 20 FTU < 2 FTU < 5 FTU < 20 FTU Water Temperature 5–45 °C 5–50 °C 5–50 °C 5–50 °C
AC 100V – 240V / AC 100V – 240V / AC 100V – 240V / AC 100V – 240V / Turbidity < 2 FTU < 2 FTU < 2 FTU < 2 FTU
Input Charge 50–60 Hz 50–60 Hz 50–60 Hz 50–60 Hz AC 100V – 240V / AC 100V – 240V / AC 100V – 240V /
Input Charge 50–60 Hz 50–60 Hz 50–60 Hz
-
Output Charge DC 12V/1.0A DC 12V/1.0A DC 12V/1.0A DC 12V/1.5A
Output Charge DC 12V/1.5A DC 24V/1.5A DC 24V/1.5A -

75504 (F68Q1) 65505 (F116Q1) 65510 (N74Q1) 93520 (F95C1)


Model 55510 (N75Q1) Model 91240B (F112CS) 93640B (F112C3)
75604 (F68Q3) 65605 (F116Q3) 65610 (N74Q3) 93620 (F95C3)
Water Capacity 4 m3/h 4 m3/h 10 m3/h 3
10 m /h Water Capacity 20.5 m3/h 40 m /h 3
40 m3/h
Running Model Time Clock / Meter Time Clock / Meter Time Clock / Meter Time clock Running Model Time Clock / Meter Manual Softener Meter
Regeneration Type Upflow Downflow Downflow - Regeneration Type Upflow Upflow Upflow
Mount Type Top Mount Top Mount Top Mount Top Mount Mount Type Side Mount Side Mount Side Mount
Inlet/Outlet 1"M 1"M 2"M 2"M Inlet/Outlet 2"M DN65 DN65
Drain 3/4"NPT 3/4"NPT 1"M 2"M Drain 1.5"M DN65 DN65
Brine Tank Connector 3/8"M 3/8"M 1/2"M - Brine Tank Connector 3/4"M 3/4"M 3/4"M
Base 2.5"-8NPSM 2.5"-8NPSM 4"-8UN 4"-8UN
Base - - -
Riser Pipe 1.05" OD 1.05" OD 1.5"D-GB or 1.9" OD 1.5"D-GB or 1.9" OD
Available Tank Size 6"–14" 6"–14" 20"–30" 16"–24" Side mount, top and bottom Side mount, top and bottom Side mount, top and bottom
Riser Pipe distributor 2"M distributor DN80 distributor DN80
Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.2–0.6 MPa 0.15–0.6 MPa
Available Tank Size 20"–30" 36"–40" 36"–40"
Water Temperature 5–45 °C 5–45 °C 5–50 °C 5–50 °C
Working Pressure 0.2–0.6 MPa 0.2–0.6 MPa 0.2–0.6 MPa
Turbidity < 2 FTU < 5FTU < 5 FTU < 20 FTU
Water Temperature 5–50 °C 5–50 °C 5–50 °C
AC 100V – 240V / AC 100V – 240V / AC 100V – 240V / AC 100V – 240V /
Input Charge 50–60 Hz 50–60 Hz 50–60 Hz 50–60 Hz Turbidity < 2 FTU < 2 FTU < 2 FTU
Output Charge DC 12V/1.5A DC 12V/1.5A DC 24V/1.5A DC 24V/1.5A Input Charge AC 100V – 240V / 50–60 Hz - AC 100V – 240V / 50–60 Hz
Output Charge DC 24V/1.5A - DC 24V/1.5A

34 www.snowate.com www.snowate.com 35
Residential D Series

Structure & Performance Features

● LCD display, intuitional and convenient. Model 82602E (F105A3) 82603FD (F136BHW) 82604E (F97A3) 52504H (F67D1)

● Indication of long time power off, data saved after power off (saved for three days.) Water Capacity 2 m3/h 3 m3/h 4 m3/h 4 m3/h
● Up-flow valve can set interval backwash times F-00, which can realize several times service and one time backwash. Running Model Meter Meter Meter Time Clock
Regeneration Type Downflow/Upflow Downflow/Upflow Downflow/Upflow -
● Downflow or Upflow option can be set in the program, and also can mix hard water to the system if required not too soft water.
Mount Type Top Mount Top Mount Top Mount Top Mount
● With disinfection connector which can be connected with disinfection device to electrolyze brine during regeneration to disinfect. Inlet/Outlet 3/4"M G1" 3/4"M 1"F
● D series valve has foreground and background modes to prevent incorrect operation. Drain 1/2"M NPT 3/4" 1/2"M 1"F
Brine Tank Connector 3/8"M 3/8"M 3/8"M -
● F105 and F97 use soft water for brine refilling, both UF and DF option, have vacation mode and dry brine mode.
Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM
● F105 and F79 has the leakage protection function; F105 has the function of proportinally brine draw and brine refill based on the Riser Pipe 1.05" OD 1.05" OD 1.05" OD 1.05" OD
percentage of real capacity Available Tank Size 6"–10" 6"–12" 6"–14" 6" to 14"
Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa
Water Temperature 5–50 °C 5–50 °C 5–50 °C 5–50 °C
Application Turbidity
Downflow < 5 FTU, Downflow < 5 FTU Downflow < 5 FTU
< 20 FTU
Upflow < 2 FTU Upflow < 2 FTU Upflow < 2 FTU
● Residential Softener or the Whole House Water Softener. AC 100V – 240V / AC 100V – 240V / 50–60 AC 100V – 240V / 50–60 AC 100V – 240V /
Input Charge 50–60 Hz Hz Hz 50–60 Hz
● RO Pre-treatment Softener.
Output Charge DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A

82602 82602
62502 (F65D1) 72502 (F69D1)
Model 52502H (F71D1) (F79A-LCD, LED are (F79B-LCD, LED are
62602 (F65D3) 72602 (F69D3)
also available.) also available.)
62504 (F63D1) 72504 (F68D1) 82604 (F82A-LCD) 82604 (F82A-LED)
Water Capacity 2 m3/h 2 m3/h 2 m3/h 2 m3/h 2 m3/h Model
62604 (F63D3) 72604 (F68D3) 82604B (F82B-LCD) 82604B (F82B-LED)
Running Model Time Clock Time Clock / Meter Time Clock / Meter Meter Meter
Regeneration Type - Downflow Upflow Downflow/Upflow Downflow/Upflow Water Capacity 4 m3/h 4 m3/h 4 m3/h 4 m3/h

Mount Type Top Mount Top Mount Top Mount Top Mount Top Mount Running Model Time Clock / Meter Time Clock / Meter Meter Meter
Inlet/Outlet 3/4"M 3/4"F 3/4"F 3/4"M 3/4"M Regeneration Type Downflow Upflow Downflow/Upflow Downflow/Upflow

Drain 3/4"M 1/2"M 1/2"M 1/2"M 1/2"M Mount Type Top Mount Top Mount Top Mount Top Mount

Brine Tank Inlet/Outlet 1"M 1"M 1"M 1"M


- 3/8"M 3/8"M 3/8"M 3/8"M
Connector Drain 1/2"M 1/2"M 1/2"M 1/2"M
Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM Brine Tank Connector 3/8"M 3/8"M 3/8"M 3/8"M

Riser Pipe 1.05" OD 1.05" OD 1.05" OD 1.05" OD 1.05" OD Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM

Available Tank Size 6"–10" 6"–10" 6"–10" 6"–10" 6"–10" Riser Pipe 1.05" OD 1.05" OD 1.05" OD 1.05" OD

Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa Available Tank Size 6" to 18" 6" to 18" 6" to 18" 6" to 18"
Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa
Water Temperature 5–50 °C 5–50 °C 5–50 °C 5–50 °C 5–50 °C
Water Temperature 5–50 °C 5–50 °C 5–50 °C 5–50 °C
Turbidity < 20 FTU < 5 FTU < 2 FTU < 5 FTU < 5 FTU
Turbidity < 5 FTU < 2 FTU < 5 FTU < 5 FTU
AC 100V – 240V / AC 100V – 240V / AC 100V – 240V / AC 100V – 240V / AC 100V – 240V / AC 100V – 240V / AC 100V – 240V / AC 100V – 240V / AC 100V – 240V /
Input Charge 50–60 Hz 50–60 Hz 50–60 Hz 50–60 Hz 50–60 Hz Input Charge 50–60 Hz 50–60 Hz 50–60 Hz 50–60 Hz

Output Charge DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A Output Charge DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A

36 www.snowate.com www.snowate.com 37
Special Application Control Valves Bypass Valves Series

F107&F107C
Iron-Manganese Removal Device
It is composed of aeration device and multiport control valves. The device adopts
impeller stirring plus dropping create aeration process.
And automatic air release valve constantly drain off the air and carbon dioxide in water.
Combining with automatic filter control valves, this device can help to remove the iron or manganese from the water Model 41104 (F70A) 41102 (F70B) 41204 (F70C)
which has a big containing, as a pre-treatment device before industrial softening system or demineralization system. Water Capacity 4 m3/h 2 m3/h 4 m3/h
Inlet 1"M 3/4"M 1"M
Outlet 1"M 3/4"M 1"M
Valve Size 1"F 3/4"M 1"F
Inlet & Outlet Distance 50 mm 65/70 mm 50 mm

Model F107 F107C Working Pressure 0.6 MPa 0.6 MPa 0.6 MPa

Water Capacity 2 m3/h 10 m3/h Water Temperature 5–50 °C 5–50 °C 5–50 °C

Outlet Water Iron Content Iron content < 0.3 mg/L Iron content < 0.3 mg/L Remark Suited for F63/F68 Valve Suited for F65/F69 Valve Suited for F63/F68/F82 Valve

Outlet Water Manganese Content < 0.1 mg/L < 0.1 mg/L
Outlet Water Turbidity < 5 mg/L < 5 mg/L
Inlet Water Iron Content Iron content < 20 mg/L Iron content < 20 mg/L
Inlet Water Manganese Content < 3 mg/L < 3 mg/L
Inlet Water Turbidity < 15 mg/L < 15 mg/L
Alkalinity < 2 mg/L < 2 mg/L
pH Value 6.8–9 6.8–9
Water Temperature 6–10 °C 6–10 °C Model 41202 (F70D) 41206 (F70F) 41205 (F70G)
Water Capacity 2 m3/h 6 m3/h 5 m3/h
Inlet 3/4"M 1"M NPT 3/4"M or 1"M or NPT 1"M
Outlet 3/4"M 1"M NPT 3/4"M or 1"M or NPT 1"M
Control Valve for Achieving One Valve on Duplex Tanks and Valve Size 3/4"M NPT 1" or 1"M 3/4"M or 1"M or NPT 1"M
Working in Series Inlet & Outlet Distance 50 mm 50 mm 50 mm
Working Pressure 0.6 MPa 0.6 MPa 0.6 MPa
● Patented design: one valve on duplex tanks, working in series; Water Temperature 5–50 °C 5–50 °C 5–50 °C
● Under 0.1 MPa pressure drop, the flow rate is 4 m3/h; Remark Suited for F79 Valve Suited for F92/F97 Valve
Suited for F63/F68/F79/F82/F105/
F136 Valve
● Filter + softening duplex tanks work in series system;
● Ozone + filter duplex tanks for iron and manganese removal system works in series;
● Duplex tanks softener system works in series;
● Three or more tanks can be realized in series.

Model 12504 (F142A1) 12604 (F142A3) 12504 (F142B1) 12604 (F142B3)


Water Capacity 4 m3/h 4 m3/h 4 m3/h 4 m3/h
Running Model Time Clock Meter Time Clock Meter
Downflow, Downflow, Downflow, Downflow,
Model 41302 (F70H) 41103 (F70I) 41302Y (F70HYL)
Regeneration Type
brine drawing brine drawing Ozone drawing Ozone drawing Water Capacity 2 m3/h 3 m3/h 2 m3/h
Mount Type Top Mount Top Mount Top Mount Top Mount Inlet 3/4"M 1"M 3/4"M
Inlet/Outlet G1" G1" G1" G1" Outlet 3/4"M 1"M 3/4"M
Drain NPT 3/4" NPT 3/4" NPT 3/4" NPT 3/4"
Valve Size 3/4"M 1"M 3/4"M
Brine Tank Connector G3/8" G3/8" G3/8" G3/8"
Inlet & Outlet Distance 50 mm 50 mm 50 mm
Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM
Riser Pipe 1"D-GB 1"D-GB 1"D-GB 1"D-GB Working Pressure 0.6 MPa 0.6 MPa 0.6 MPa

Turbidity < 5 FTU < 5 FTU < 5 FTU < 5 FTU Water Temperature 5–50 °C 5–50 °C 5–50 °C

AC 100V – 240V / AC 100V – 240V / AC 100V – 240V / AC 100V – 240V / Remark Suited for F67N/F122 Valve Suited for F79BD Valve Suited for F105/F126 Valve
Transformer Input
50–60 Hz 50–60 Hz 50–60 Hz 50–60 Hz
Transformer Output DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A

38 www.snowate.com www.snowate.com 39
Appendix-1

Bypass Valve
Filter Manual Softener Automatic Downflow Automatic Upflow
New Model Old Model Remark
Water Capacity Manual Automatic Downflow/Upflow Time Clock Type Meter Type Time Clock Type Meter Type 41104 F70A Suited with F63/F68
41102 F70B Suited with F65/F69
51201A/51201B/51201C 53502/52502H/53502B 63502/62502/63502B 63602/62602/63602B/ 73502/72502/73502B 73602/72602/73602B
61202/61202C 41204 F70C Suited with F63/F68/F82
51102/51202C 64502/55502 64502/65502 64602/65602 74502/74502Y 74602
1–2 m3/h 41202 F70D Suited with F79
F52/F56B/F56C/F56E/ F71B1/F71D1/F71G1/ F65B1/F65D1/F65G1 F65B3/F65D3/F65G3 F69A1/F69D1/F69G1 F69A3/F69D3 41206 F70F Suited with F97/92
F64B/F64BC
F56EC F71P/F71Q F65P1/F117Q1 65P3/F117Q3 F69P1/F69PY F69G3/F69P3 41304 F70G Suited withF63/F68/F79/F82/F105
41302 F70H Suited with F67N/F122
41103 F70I Suited with F79
53504S/53504/52504H/
63504S/63504/62504/ 63604S/63604/63604B 73504S/73504/72504 73604S/73604/72604/
51104/51204C/51240 53504B/54504/55504/ 61104/61204C
63504B/64504/65504 64604/65604 73504B/74504/74504Y 73604B/74604
56603/52504E
3–4 m3/h
Others
F67B/F67C1/F67D1/ Water Treatment
F63B1/F63C1/F63D1 F63B3/F63C3/F63G3 F68A1/F68C1/F68D1/F68G1/ F68A3/F68C3/F68D3 Product New Model Old Model
F56A/F56K/F56AC F67G1/F67P/F67Q/F67N/ F64A/F64AC Capacity
F63G1/F63P1/F116Q1 F63P3/116Q3 F68P1/F68PY F68G3/F68P3
F67K
83602 F79 2 m3/h
Downflow/Upflow 82602 F105 2 m3/h
51106 53506S/53504-A 61206 63505E/63505 63605E/63605 72505/73505 72605/73605
Softener 82603E F97A3 3 m3/h
3
5–6 m /h 83604 F82A3 4 m3/h
F56F F67B-A/F67C1-A N64F F116A1/F130A1 F116A3/F130A3 F92A1-LCD/F92A1-LED F92A-LCD/F92A-LED 93604 F83A3 4 m3/h
93606 F98C 6 m3/h
53508/53510/ 63508/63510 Control Valve for Floating 93610 F88C 10 m3/h
51208/51210 61210 63610/63610B
53510B/55510 /63510B/65510 Bed 92115 F77CS 15 m3/h
8-10 m3/h 93620 F95C3 20 m3/h
F134A/N75A1/N75B1/ F133A/N74A1 93640 F112C3 40 m3/h
F56L/N56D N64D N74A3/N74B3
N75Q N74B1/N74Q
17603 F73 3.5 m3/h
17606 F98A 6 m3/h
51215 53518/53515/53615 61215 63518/63515 63618/63615 73515 73615 One Valve on Duplex
17606T F137 6 m3/h
12–18 m3/h Tanks
17610T F135 10 m3/h
F77BS N77B1/F99B1/F99B3 F77AS N77A1/F99A1 N77A3/F99A3 F99D1 F99D3 17610 F88A 10 m3/h
Electronic Three-way
53520/53620 63520/63520T 63620/63620T 73520 73620 42020 F80 20 m3/h
3 Valve
20 m /h
F95B1/F95B3 F95A1/F111A1 F95A3/F111A3 F95D1 F95D3
On-line Sampling
44310 F84
51240B 53540B/53640B 61240B 63540B 63640B Monitory Device
30–40 m3/h
F112BS F112B1/F112B3 F112AS F112A1. F112A3 45006 F90A 6 m3/h
45012 F90B 12 m3/h
53550/53650 63550 63650 Disc Filter
3
50 m /h 45020 F90C 20 m3/h
F96B1/F96B3 F96A1 F96A3 45040 F90D 40 m3/h

40 www.snowate.com www.snowate.com 41
Appendix-2

Type New Model Old Model Inlet/Outlet Drain Base Riser Pipe Brine Line Connector Water Capacity (m3/h) Tank Size Regeneration Mode Water Pressure Turbidity

51102/51202/51202C F56E1/F56E2/F56EC 1/2"F or 3/4"F 1/2"F or 3/4"F 2.5"-8NPSM 1.05" OD 2 6"-10"

51104/51204C/51104K F56A/F56AC/F56K 1"F 1"F 2.5"-8NPSM 1.05" OD 4 6"-12"


51106/51206 F56F1/F56F2 1"F 1"F 2.5"-8NPSM 1"D-GB 6 6"-14"
1.25"D-GB 0.15–0.6 MPa
51208 F56L 1.5"M 1.5"M 4"-8UN 8 10"-24"
Manual Filter 1.66" OD <20FTU
1.5"D-GB
51110/51210 N56D1/N56D2 2"F 2"F 4"-8UN 10 10"-24"
1.9" OD
1.5"D-GB
51215 F77BS 2"M 2"M 4"-8UN 15 30" – 40"
1.9" OD
51240B F112BS DN65 DN65 Side-Mounted, DN80 Top and bottom strainer connector 40 36"-48" 0.2–0.6 MPa
53502/53602/53502B/53502P/52502H/55502 F71B1/F71B3/F71G1/F71P/F71D/F71Q 3/4"M 3/4"M 2.5"-8NPSM 1.05" OD 2 6"-10"
1"F
53504/53504S/53504B/53504C/53504P/52504H/55504/56603M/52504E F67C/F67B/F67G/F67I/F67P/F67D/F67Q/F67M/F67K F67D/F67K: 1"M 2.5"-8NPSM 1.05" OD 4 6"-24" 0.15–0.6 MPa
F67M: 3/4"M - -

53506S F67B1-A 1"F 1"F 2.5"-8NPSM 1"D-GB 6 6"-24"


1.25"D-GB
53508/53608 F134A1/F134A3 1.5"M 1.5"M 4"-8UN 8 16"-24"
1.66" OD
1.5"D-GB
53510/53510B N75A/N75B 2"M 2"M 4"-8UN 10 6"-24"
1.9" OD
Automatic Filter <20FTU
1.5"D-GB
53515 F99B 2"M 2"M 4"-8UN 15 20"-30"
1.9" OD
1.5"D-GB 0.2–0.6 MPa
53518 N77B1 2"M 2"M 4"-8UN 18 24"-30"
1.9" OD
53520T/53620T F111B1/F111B3 2"M 2"M 4"-8UN 2"D-GB 20 36"-48"
53520/53620 F95B1/F95B3 2"M 2"M Side-Mounted, 2"M Top and bottom strainer connector 20 30"-36"
53540B/53640B F112B1/F112B3 DN65 DN65 Side-Mounted, DN80 Top and bottom strainer connector 40 36"-48"
53550/53650 F96B1/F96B3 DN80 DN80 Side-Mounted, DN100 Top and bottom strainer connector 50 36"-48"
61202/61202C/71202C F64B/F64BC/F64C 3/4"F 1/2"M 2.5"-8NPSM 1.05" OD 3/8"M 2 6"-12"
61104/61204/61204C F64A1/F64A3/F64AC 1"F 1/2"M 2.5"-8NPSM 1.05" OD 3/8"M 4 6"-18"
0.15–0.6 MPa
61206 N64F 1.5"M 3/4"M 4"-8UN 1.25"D-GB 1/2"M 6 10"-28"
Manual Soften Downflow <5FTU
61210 N64D 2"M 1"M 4"-8UN 1.5"D-GB 1/2"M 10 10"-30"
61215 F77AS 2"M 2"M 4"-8UN 1.5"D-GB 3/4"M 15 30"-40"
0.2–0.6 MPa
61240B F112AS DN65 DN65 Side-Mounted, DN80 Top and bottom strainer connector 3/4"M 40 48"-60"
63502/63502B/63502P/62502/65503 F65B/F65G/F65P/F65D/F117Q 3/4"F 1/2"M 2.5"-8NPSM 1.05" OD 3/8"M 2 6"-12" Downflow <5FTU
73502/73502B/73502P/72502/75502 F69A/F69G/F69P/F69D/F69Q 3/4"F 1/2"M 2.5"-8NPSM 1.05" OD 3/8"M 2 6"-12" Upflow <

63504S/63504/63504B/63504C/63504P/62504/65505/63505E F63B/F63C/F63G/F63I/F63P/F63D/F116Q/F116E 1"M 1/2"M 2.5"-8NPSM 1.05" OD 3/8"M 4 6"-18" Downflow <5FTU
0.15–0.6 MPa
73504S/73504/73504B/73504P/72504/75504 F68A/F68C/F68G/F68P/F68D/F68Q 1"M 1/2"M 2.5"-8NPSM 1.05" OD 3/8"M 4 6"-18" Upflow <2FTU
63505/63605 F116A1/F116A3 1"M 3/4"M 2.5"-8NPSM 1.05" OD 3/8"M 4 6"-18" Downflow <5FTU
73505/73605 F92A1/F92A3 1"M 3/4"M 2.5"-8NPSM 1"D-GB 3/8"M 5 10"-24" Upflow <2FTU
1.25"D-GB
63508/63608 F133A1/F133A3 1.5"M 3/4"M 4"-8UN 1/2"M 8 24"-30" Downflow <5FTU
1.66" OD
1.5"D-GB
63510/63510B N74A/N74B 2"M 1"M 4"-8UN 1/2"M 10 20"-30" Downflow <5FTU
1.9" OD
Automatic Softener 1.5"D-GB F99A Downflow Downflow<5FTU
63515/73615 F99A/F99D 2"M 1.5"M 4"-8UN 3/4"M 15 30"-40"
1.9" OD F99D Upflow Upflow<2FTU
1.5"D-GB 0.2–0.6 MPa
63518/63618 N77A1/N77A3 2"M 1.5"M 4"-8UN 3/4"M 18 30"-40" Downflow <5FTU
1.9" OD
F95A Downflow Downflow<5FTU
63520/73520 F95A/F95D 2"M 1.5"M Side-Mounted / 3/4"M 20 30"-48" F95D Upflow Upflow<2FTU
63520T F111A 2"M 1.5"M 4"-8UN 2"D-GB 3/4"M 20 36"-48" Downflow <5FTU
63540B F112A DN65 DN65 Side-Mounted, DN80 Top and bottom strainer connector 3/4"M 40 48"-60" Downflow <5FTU
63550 F96A DN80 DN80 Side-Mounted, DN100 Top and bottom strainer connector 3/4"M 50 60"-72" Downflow <5FTU
82602/82602B F79A-LCD/F79B-LCD 3/4"M 1/2"M 2.5"-8NPSM 1.05" OD 3/8"M 2 6"-18" Down/Upflow <5FTU or <2FTU
0.15–0.6 MPa
83604/82604B F82A-LCD/F82B-LCD 1"M 1/2"M 2.5"-8NPSM 1.05" OD 3/8"M 4 6"-18" Down/Upflow <5FTU or <2FTU
17603 F73 1"M 1/2"M 2.5"-8NPSM 1.05" OD 3/8"M 3.5 12"-14" Down/Upflow <5FTU or <2FTU
17606 F98A 1"M 3/4"M Side-Mounted, 1"M Top and bottom strainer connector 1/2"M 6 20"-24" Upflow 0.15–0.6 MPa <2FTU

One Valve On Duplex Tanks 17610 F88A 1.5"M 1"M Side-Mounted, 1.5"M Top and bottom strainer connector 1/2"M 10 20"-30" Upflow <2FTU
1.5"D-GB
17610T F135A 1.5"M 3/4"M 4"-8UN 1/2"M 10 20"-30" Downflow <5FTU
1.9" OD 0.2–0.6 MPa
17606T F137 1"M 3/4"M 4"-8UN 1.5"D-GB (32 mm OD) 1/2"M 6 16"-24" Top mounted Downflow <5FTU
93504 F83A 1"'M 1/2"M 2.5"-8NPSM 1.05" OD 3/8"M 4 10"-14" 0.15–0.6 MPa <2FTU
93606 F98C 1"M 3/4"M Side-Mounted, 1"M Top and bottom strainer connector 1/2"M 6 18"-24" <2FTU
93610 F88C 1.5"M 1"M Side-Mounted, 1.5"M Top and bottom strainer connector 1/2"M 10 20"-24" <2FTU
Control Valve for Floating Bed Floating Bed
91215 F77CS 2"M 2"M 4"-8UN 1.5"D-GB 3/4"M 15 20"-30" 0.2–0.6 MPa <2FTU
93520/93620 F95C1/F95C3 2"M 1.5"M 3/4"M 2"M 3/4"M 20 30"-36" <2FTU
91240B/93540B F112CS/F112C DN65 DN65 Side-Mounted, DN80 Top and bottom strainer connector 3/4"M 40 36"-48" <2FTU
Control valve for achieving 12604 F142A 1"M NPT3/4 2.5"-8NPSM 1"D-GB 3/8"M 4 6"-18" Downflow (Brine Draw) <5FTU
one valve on duplex tanks and 0.15–0.6 MPa
working in series 12504 F142B 1"M NPT3/4 2.5"-8NPSM 1"D-GB 3/8"M 4 6"-18" Downflow (Air Draw) <5FTU

42 www.snowate.com www.snowate.com 43
TM

Ms Snow Zhao
[email protected]
Mobile: +86-15030811699
(WhatsApp, WeChat, Skype, Viber)

Hengshui Snowate Environmental Technology Co., Ltd.


www.snowate.com

You might also like