KCE FAULT CODES R11.0 958174D03 en.E.

FaultCode FaultName

1000 Serial communication broken on board (both TTS channels)

1001 Board added after setup

1002 Serial communication broken on board (TTS-1)

1003 Serial communication broken on board (TTS-2)

1004 TTS serial communication broken. One channel

1005 TTS serial communication broken. Both channels

1006 KCEMSC board failure - Serial communication broken

1007 Safety circuit: Final limit (C1)

1008 Safety circuit: Safety gear (C2)

1009 Safety circuit: Emergency exit (C3)

1010 Safety circuit: blocking device (C4)

1011 Car door contact opened during drive (C5)

1012 Rear car door contact opened during drive (C6)

1013 Safety circuit: car top balustrade not down while on normal mode (C7)

1014 Safety circuit: Hoist way access enable activated while driving

1015 Safety circuit: car top balustrade not up while on inspection mode (C8)

1016 Safety circuit: Fireman stop switch

1017 Safety circuit: in-car stop switch

1018 Deceleration failure

1019 Inspection run overspeed

1020 Overspeed during ADO

1021 Overspeed during relevelling doors open

1022 Speed information missing during inspection mode

Copyright © 2015 KONE Corporation Page 1/20


KCE FAULT CODES R11.0 958174D03 en.E.1

FaultCode FaultName

1023 Car door bypass switch active

1024 Hoistway door bypass switch active

1025 NTS supervision activated

1028 ETS supervision activated

1029 Safety circuit: Pit safety contact open (H1)

1030 Safety circuit: buffer contact or OSG contact (H2)

1031 Safety circuit: Landing door opened during drive

1032 Safety circuit: swing door opened during drive

1033 Safety circuit: Buffers supervision. Up input failure

1034 Safety circuit: Buffers supervision. Down input failure

1035 Unintended movement

1036 Inner door zone supervision

1037 Faulty door contact

1038 Car door contact and car door close end signal does not match

1039 Door open monitoring functioned

1040 Drive time supervision

1041 Person in shaft reset switch stuck

1042 Additional limit switch failure

1043 Start permit fault

1044 Drive not OK

1045 Pit inspection buttons stuck on

1046 Brake feedback fault

1047 Car top inspection buttons on stuck

Copyright © 2015 KONE Corporation Page 2/20


KCE FAULT CODES R11.0 958174D03 en.E.1

FaultCode FaultName

1048 KMI inspection buttons on stuck

1049 HAC landing switch on stuck

1050 KCEMSC board failure - Sw version cross check

1051 KCEMSC board failure - Safety input common test

1052 KCEMSC board failure - Safety input test

1053 KCEMSC board failure - Safety input cross check

1054 Safety circuit: ground fault

1055 Safety circuit: power supply voltage out of 10 % range

1056 Safety circuit: power supply voltage out of 15 % range

1057 Safety circuit: power supply voltage out of 20 % range

1058 Speed comparison warning

1059 KCEMSC board failure - ROM test

1060 KCEMSC board failure - RAM test

1061 KCEMSC board failure - Internal data comparison

1062 KCEMSC board failure - No reciprocal communication

1063 KCEMSC board failure - Relay K51 feedback

1064 KCEMSC board failure - Relay K52 feedback

1065 SSA safety device check failed

1066 24 V power supply voltage out of +- 10 % range

1068 24V power supply voltage out of +- 20 % range

1069 KCEMSC board failure - 3.3 V power supply

1070 KCEMSC board failure - Processor core power supply

1071 Energy saving warning

Copyright © 2015 KONE Corporation Page 3/20


KCE FAULT CODES R11.0 958174D03 en.E.1

FaultCode FaultName

1072 Energy saving failure

1073 Person in shaft detection input failure

1074 TTS communication disturbance

1075 KCEFUI board disconnected

1076 KCEMSC board failure - Shift registers

1077 KCEMSC board failure - Relay K41 feedback

1078 KCEMSC board failure - Relay K42 feedback

1079 KCEMSC board failure - 100V power supply

1080 KCEMSC DIP switch mismatch

1081 KCEMSC board failure - Input comparison

1082 KCEMSC board failure - Comparison of KCEFUI inputs

1083 KCEDZS A data comparison failure

1084 KCEDZS B data comparison failure

1085 KCEDZS C data comparison failure

1086 KCEDZS D data comparison failure

1087 KCEABS data comparison failure

1088 KCECCG-1 data comparison failure

1089 KCECCG-2 data comparison failure

1090 KCECPU data comparison failure

1091 Lift on final limit magnet

1092 Internal KCEFUI board failure - OSG test input

1093 Too much resistance on landing door contact

1094 Induced noise in landing door contact

Copyright © 2015 KONE Corporation Page 4/20


KCE FAULT CODES R11.0 958174D03 en.E.1

FaultCode FaultName

1095 DOM resistor failure

1096 KCEFUI board failure - Button stuck

1097 Device picked fault

1098 Motion control data comparison failure

1099 Main stop switch open

1100 Accelerometer failure on KCEDZS board

1101 Door zone information mismatch

1102 Speed comparison fault

1103 KCEMSC board failure - ROM test

1104 KCEMSC board failure - IO controller

1105 Boards in TTS network are not compatible

1106 Setup failed

1108 Door open end reached before lift stops

1109 Landing door not opened after inspection mode switched OFF

1110 Additional 24V measurement failure

1111 KCEFUI SPI failure

1112 KCEFUI board failure - Safety input test

1113 TTS communication stuck

1114 Pit inspection mode input failure

1115 KCEMSC board failure - Safety input power supply

1116 KMI safety chain bypass jumper at place

1117 KMI stop switch active

1118 KCECCG-2:Safety circuit Final limit

Copyright © 2015 KONE Corporation Page 5/20


KCE FAULT CODES R11.0 958174D03 en.E.1

FaultCode FaultName

1119 KCECCG-2 Safety circuit: Safety gear

1120 KCECCG-2 Safety circuit: KCECCG-2 emergency exit

1121 KCECCG-2 Safety circuit: KCECCG-2 blocking device

1122 KCECCG-2 Car door contact opened during drive

1123 KCECCG-2 Rear car door contact opened during drive

1124 KCECCG-2 Safety circuit: car top balustrade not down while on normal mode

1125 KCECCG-2 Safety circuit: Hoist way access enable activated while driving

1126 KCECCG-2 Safety circuit: car top balustrade not down while on normal mode

1127 KCECCG-2 Safety circuit: Fireman stop switch

1128 KCECCG-2 Safety circuit: in-car stop switch

1129 Inspection drive unit stop button active

1130 SSA input supervision reservation warning

1131 SSA input supervision reservation failure

1132 Pit inspection mode reset input active too long

1133 Terminal floor deceleration failure

1134 Deck configuration mismatch

1135 Safety output control signal failure (Relay A, K51)

1136 Safety output control signal failure (Relay B, K52)

1137 Safety output control signal failure (Relay A, K41)

1138 Safety output control signal failure (Relay B, K42)

1139 KCEMSC - KCEFUI boards mismatch (wrong version)

1140 Safety circuit: Inspection up limit

1141 Safety circuit: Inspection down limit

Copyright © 2015 KONE Corporation Page 6/20


KCE FAULT CODES R11.0 958174D03 en.E.1

FaultCode FaultName

1142 KCECCG-2 Safety circuit: Inspection up limit

1143 KCECCG-2 Safety circuit: Inspection down limit

1145 Floor number check failed

1146 Position magnet failure - Floor type / magnet type mismatch

1147 Position magnet upside down

1148 KCECCG board failure - Self check failed

1149 KCECCG board failure - Manual reset needed

1150 Final limit missing

1151 KCEMSC DIP switch failure (DIP 5)

1152 KCECCG internal failure

1153 KCEMSC board failure - Production test input

1154 KCECCG-2: Safety circuit S1

1155 KCECCG-2: Safety circuit S2

1156 Pendant input on stuck

1157 KCEMSC board failure - Assembly variant input

1158 KCEMSC board failure - Assembly variant detection

1159 KCEMSC board failure - Nameplate

1160 KCEFUI board failure - Test switch

1161 KCEDZS board failure - Self check failed

1162 KCEDZS board failure - Manual reset needed

1164 KCEMSC configuration failure - DIP 2 position changed

1165 KCEMSC configuration failure - DIP 6

1166 KCEMSC configuration failure - DIP 6 position changed

Copyright © 2015 KONE Corporation Page 7/20


KCE FAULT CODES R11.0 958174D03 en.E.1

FaultCode FaultName

1167 Board changed after setup

1168 Linear position failure while standing

1169 Linear position failure when moving

1170 Overspeed start between floors

1171 KCEMSC setup data corrupted

1172 KCEMSC internal failure

1173 Final limit detection failure during setup

1174 KCEMSC board failure - Safety input test register

1175 Safety system in Safe mode

1176 EMC disturbance warning

1177 EMC disturbance warning

1178 KCEMSC board failure

1179 KCEMSC DIP switch compatibility failure

1180 Speed information missing (ADO or ACL mode)

1181 Door bypass switch misuse

1182 KCEMSC configuration failure - DIP position changed

1183 KCEMSC board failure - short circuit on feedback inputs

1184 KCEMSC board failure - Relay K51 feedback

1185 KCEMSC board failure - Relay K52 feedback

1186 KCEMSC board failure warning - Relay K41 feedback

1187 KCEMSC board failure warning - Relay K42 feedback

1188 Safety circuit: Buffers up input (H7)

1189 KCEMSC board internal failure

Copyright © 2015 KONE Corporation Page 8/20


KCE FAULT CODES R11.0 958174D03 en.E.1

FaultCode FaultName

1190 Device picked input dropped while lift running

1191 Drive interface type changed after setup

1192 Wrong type final limit magnet

1193 KCEMSC board failure - EEPROM

1194 Unintended movement warning

1195 KCEMSC board failure - setup data

1196 KCEMSC board failure - EEPROM on other channel

1197 KCEMSC main relay failure

1198 KCEMSC secondary relay failure

1199 Operation mode not allowed

1200 KCECCG board failure

1201 KCECCG board failure

1202 KCECCG board failure

1203 KCECCG board failure

1204 KCECCG 24V power supply failure

1205 KCECCG board failure - 3.3 V power supply

1206 KCECCG board failure - Software version cross-check

1207 Serial communication lost on KCECCG

1208 KCECCG board failure - No internal communication

1209 KCECCG board failure - Data comparison

1212 KCECCG board failure - 24V power supply

1213 Serial communication stuck failure

1214 Jumper failure on KCECCG KCEAPS connector

Copyright © 2015 KONE Corporation Page 9/20


KCE FAULT CODES R11.0 958174D03 en.E.1

FaultCode FaultName

1215 CCG Production Test Input Failure in TTS

1216 KCECCG TTS Nameplate Failure

1300 KDEDZS reader unit broken

1301 Magnet failure - RFID tag missing from magnet

1302 Magnet failure - Tag type error

1303 Magnet not found in setup table

1304 Magnet failure - Tags missing from magnet

1305 KCEDZS reader unit distance from magnet too long

1306 Magnet signal weak

1307 KCEDZS self check failure

1309 Magnet upside down

1310 Magnet failure - Tag corrupted

1313 Magnet failure - Duplicate UID

1314 Magnet failure - RFID tag incorrect in magnet

1315 Setup failure - final limit detection

1317 Magnet reading failure - linear position cross check

1318 Magnet failure - RFID tag incorrect

1319 Magnet failure - RFID tag info missing

1320 KCEDZS internal fault: calibration check sum incorrect

1321 KCEDZS internal fault: Hal calibration missing

1322 KCEDZS internal fault: Hal calibration validation

1325 KCEDZS internal fault: Hall sensor on stuck

1326 KCEDZS internal fault: Undefined segment

Copyright © 2015 KONE Corporation Page 10/20


KCE FAULT CODES R11.0 958174D03 en.E.1

FaultCode FaultName

1329 KCEDZS: internal fault: over speed measured

1331 KCEDZS: Internal fault: One channel serial communication

1332 KCEDZS internal failure - microprosessor failure

1333 KCEDZS internal fault - input failure

1334 KCEDZS internal fault - input difference compared to setup

1336 KCEDZS - internal fault cross check failed

1337 KCEDZS: internal fault - sensor check failed

1339 KCDZS 24V power suplly failure

1340 KCDZS internal failure - voltage monitoring

1341 Magnet failure - RFID reading

1342 KCEDZS internal failure - data comparison

1345 KCEDZS electronic identification missing

1346 KCEDZS Internal fault: Accelerometer on stuck

1347 KCEDZS Internal fault: Accelerometer zero offset out of range

1348 KCEDZS: Speed difference supervision

1349 KCEDZS Internal fault: Setup checksum failure

1350 KCEDZS internal fault: Setup data validation error

1351 KCEDZS Internal fault - Memory write error

1352 KCEDZS Internal fault: RFID antenna feedback out of range

1353 KCEDZS internal two-way comparison fault

1354 KCEDZS set up fault: voltage too low

1357 KCEDZS set up fault : Too many position magnets

1358 KCEDZS set up fault: Setup internal error

Copyright © 2015 KONE Corporation Page 11/20


KCE FAULT CODES R11.0 958174D03 en.E.1

FaultCode FaultName

1359 KCEDZS set up fault: Start position above target midpoint at bottom floor

1360 KCEDZS set up fault : Start position below target midpoint at top floor

1361 KCEDZS Internal fault: Linear position error

1362 Position magnet failure: Incorrect tag

1366 KCEDZS Internal fault: Linear position sensor pair cross check failure 2

1367 KCEDZS Internal fault: Setup time linear position error

1368 Final limit magnet failure

1369 Tag UID incostintency

1371 Serial communication lost on KCEDZS

1397 Position counting failure

1398 Linear position of unknown RFID

1438 Too many CRC errors on TTS

1601 Car LON serial communication data errors

1602 Serial communication data lost

1603 Car door contact does not open

1605 Car door closing timeout

1606 Car door closing failed, too many closing trials

1607 Reopen device active too long

1608 Door open end limit signal missing

1609 Door open end limit signal stuck

1610 Car battery warning

1611 Car battery empty

Copyright © 2015 KONE Corporation Page 12/20


KCE FAULT CODES R11.0 958174D03 en.E.1

FaultCode FaultName

1612 Car lights partly broken

1613 Car light failed

1614 Car door close end limit stuck

1616 Door does not open

1700 Stuck car call button

1701 Stuck landing call button

1702 Start timeout

1703 Start failed

1704 Anticreep device stuck open

1705 Anticreep device stuck close

1706 Landing door lock timeout

1707 Car door operating failure

1708 releveling failure

1709 EBD device is broken

1710 EBD battery is empty

1712 Power up

1713 Power down

1714 Ethernet cable disconnected

1716 PFD reversal

Copyright © 2015 KONE Corporation Page 13/20


KCE FAULT CODES R11.0 958174D03 en.E.1

FaultCode FaultName

1717 PFD error

1720 Swing door safety ray broken

1721 Machine room temperature too high

1722 Cylinder limit switch fault for Hydro

1723 Top final limit fault for Hydro

1724 iValve SMA fault

1729 Water sensor contact operated

1730 Fatal start permit fault.

1740 Anti Creep Not Fully Extended First Time

1741 Anti Creep Not Fully Extended Second Time

1742 Anti Creep not Fully Retracted at Up Start

1743 Anti Creep not Fully Retracted at Down Start

1746 Hydro Oil Temperature Too High

1771 LON board input malfunction

1799 Self check mode stuck.

1808 TTS protocol version mismatch

1809 Incompatible KCECPU TTS AVR SW

1813 Roll Call Failed

1814 Drive unit fault

1815 Short power failure

1816 Extra LON board in network found

1817 LON board SW version mismatch

1818 Door opening failed too many times in consecutive drives.

Copyright © 2015 KONE Corporation Page 14/20


KCE FAULT CODES R11.0 958174D03 en.E.1

FaultCode FaultName

1819 LWD device broken

1820 Drive communication broken

1821 Terminal floor deceleration magnet missing

1822 Shaft magnet missing

1823 Several shaft magnets missing

1824 Position counting failed

1825 RFID data missing from magnet

1826 Setup terminal floor fault

1827 Setup terminal deceleration fault

1828 Setup magnet fault

1829 Setup invalid data fault

1830 LON communication error

1831 LON network error

1832 Nameplate CRC error in TTS

1833 Non service warning

1834 Non service fault

1835 KCECCG door communication failure

1836 Terminal floor magnet missing

1839 KCEMSC missing from TTS-1

1840 KCEMSC missing from TTS-2

1841 Errors in TTS-1

1842 Errors in TTS-2

1844 Relevelling failed

Copyright © 2015 KONE Corporation Page 15/20


KCE FAULT CODES R11.0 958174D03 en.E.1

FaultCode FaultName

1845 Too many relevelling attempts

1846 Group Communication Failed

1848 Door and floor sides mismatch.

1849 Elevator parameter not found

1853 Internal supervision has detected fault

1854 Lift parameters reset

1855 KDSI2 CRC Error Rate

1856 Configuration Write Error

1857 Lift parameter save failed

1858 SW boot from wrong partition

1870 Non Genuine Board Found

1871 Paired Board Mismatch

1872 Required Board Not Found

1873 Unpaired Board Found

1874 Pairing Operation Failed

1875 KEN missing

1876 KEN Mismatch

1877 KEN corrupt

1878 Pairing data corrupt

1879 Time data corrupted.

1880 Duplicate board identifier

1881 KCECPU authentication chip failure

1882 KCECPU electronic nameplate failure

Copyright © 2015 KONE Corporation Page 16/20


KCE FAULT CODES R11.0 958174D03 en.E.1

FaultCode FaultName

2000 Missing COP

2001 Missing OPT

2002 Missing PIO

2003 Missing FCB

2004 Missing FOB

2007 Missing FOBG12

2008 Missing EBD

2010 Missing CCG

2011 Missing FOBG23

2030 Missing board in LON network

2031 Missing boards in LON network

2032 Duplicated LON nodes in network

2033 LON node busy

2300 KCEDZS internal RFID failure

2301 Magnet RFID failure

2302 Faulty magnet

2303 Unrecognized magnet

2307 Software version failure on KCEDZS

2308 Serial communication failure on KCEDZS

2309 Magnet upside down

2311 Magnet reading failure

2312 Unknown magnet type

2313 Duplicate tag UID

Copyright © 2015 KONE Corporation Page 17/20


KCE FAULT CODES R11.0 958174D03 en.E.1

FaultCode FaultName

2314 Terminal floor magnet missing

2315 Wrong driving direction during setup

2318 Magnets too close to each other

2319 Insufficient magnetic field from position magnet

2320 KCEDZS calibration data corrupted

2321 Calibration missing in KCEDZS

2322 KCEDZS calibration data validation error

2325 KCEDZS board failure - Hall sensor stuck

2332 KCEDZS board failure - Internal communication

2333 KCEDZS connection failure

2334 KCEDZS side changed

2336 KCEDZS board failure - Hall sensor pair comparison

2337 KCEDZS board failure - Faulty magnet sensor

2339 KCEDZS 24 V power supply failure

2340 KCEDZS board failure - 5 V power supply

2341 KCEDZS board failure - 3.3 V power supply

2342 KCEDZS board failure - Reciprocal communication

2343 KCEDZS board failure - 3 V reference voltage

2345 KCEDZS electronic nameplate missing

2349 KCEDZS Setup data lost

2350 Faulty magnet detected during setup

2351 KCEDZS board failure - EEPROM

2352 KCEDZS board internal failure

Copyright © 2015 KONE Corporation Page 18/20


KCE FAULT CODES R11.0 958174D03 en.E.1

FaultCode FaultName

2353 Inconsistent magnet reading

2355 KCEDZS board failure - variant detection

2356 KCEDZS board failure - Variant detection at startup

2357 Too many position magnets

2368 Final limit magnet failure

2371 TTS communication disturbance detected by KCEDZS

2380 KCEDZS board failure - RAM test

2381 KCEDZS board failure - ROM test

2383 KCEDZS board failure - Fault log corrupted

2384 KCEDZS board failure - Test input

2390 KCEDZS board failure - Stack overflow warning

2391 KCEDZS board failure - interrupt warning

KCEAPM Faults
4000 No initial configuration

4001 Data link failure.

4002 PSTN line missing

4003 Routine call failure

4007 Watchdog: Data Storage process restarted

4008 Watchdog: KBM Interface process restarted

4009 Watchdog: Fault logger process restarted

4010 Watchdog: Call handler process restarted

4011 Watchdog: SNMP Interface process restarted

4012 Watchdog: HW manager process restarted

4013 Watchdog: System restarted

4015 Alarm button is stuck

Copyright © 2015 KONE Corporation Page 19/20


KCE FAULT CODES R11.0 958174D03 en.E.1

FaultCode FaultName

4016 24V power failed (mains missing)

4017 12V power failed (battery failure)

4018 No connection to KCECPU

4021 Multiple KCECPUs detected

4022 Too old KCECPU SW version.

4023 SW Update failed

4024 Invalid memory stick detected

4025 Invalid SW detected

4026 Old configuration file in use

4027 Phone-application restarted API-provider

4028 Watchdog: SLFS process restarted

4030 Packet lost in ethernet communication

KCEGC Faults (Group Controller)


201 Parameter database is corrupted

202 Invalid configuration

1000 Group has no lifts

1001 Lift network connection error

1002 Lift unsupported protocol version

1004 Lift configuration error

1005 Conflicting main floors

1006 Conflicting floor heights

1007 Auto configuration failed

2000 Groups has no call giving devices

2101 Riser network connection error

2102 Riser unsupported protocol version

2103 Riser invalid group id

2111 Missing buttons from floor