The document describes an automatic pressurization system called DG PED that consists of a self-priming pump, expansion vessel, sensors, and non-return valve controlled by an inverter. The inverter maintains constant pressure by regulating pump speed based on flow rate requirements. It can work in parallel with other inverters and adapts to any pressurization system. DG PED is compact, autonomous, quiet, and high-performing.

Uploaded by

Argenis Vera
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
62 views4 pages

Scheda - Tecnica - DG PED-IT

The document describes an automatic pressurization system called DG PED that consists of a self-priming pump, expansion vessel, sensors, and non-return valve controlled by an inverter. The inverter maintains constant pressure by regulating pump speed based on flow rate requirements. It can work in parallel with other inverters and adapts to any pressurization system. DG PED is compact, autonomous, quiet, and high-performing.

Uploaded by

Argenis Vera
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Automatic pressurisation system with inverter

DG PED is an automatic pressurisation system with inverter


which integrates:
•• a high efficiency self-priming pump;
•• an expansion vessel;
•• pressure and flow rate sensors;
•• a non-return valve.
DG PED is a compact, autonomous, quiet and high performance
pumping system.
A sophisticated electronically controlled inverter, at the heart of
the system, in an intuitive way:
•• maintains the pressure of the installation constant by regulating the
speed of the pump in accordance with the required flow rate;
•• controls the hydraulic and electric operating parameters and protects
the pump from anomalies;
•• can be equipped with an expansion card that makes it possible
to work in parallel with other inverters in the pumping groups by
managing input and output signals;
•• it adapts to every type of pressurisation system, including existing
ones;
•• it limits the starting and operating currents in order to provide a
greater saving of energy.

COMPACT
ALL IN ONE
DIMENSIONS
Main components:

334 mm
Multistage self-priming pump DOMESTIC USE
Expansion vessel
Non-return valve A single DG PED meets
Intuitive control panel the requirements of single
apartments or small houses. 215 mm 38 9 m m

LOW-NOISE

CONSTANT PRESSURE
RESIDENTIAL USE
EASY TO USE Two DG PED assembled as a
set meet the requirements
of more than one apartment.
INSTALLABLE
ANYWHERE
Thanks to its compactness and
low noise level the DG PED can be
installed anywhere

Pending certification
TECHNICAL DATA APPLICATION LIMITS
•• Supply voltage ~ 230 V ± 10% •• Manometric suction lift up to 8 m
•• Frequency 50/60 Hz •• Liquid temperature between 0 °C and +40 °C
•• Insulation: class F •• Ambient temperature betwee 0 °C and +40 °C
•• Max. working pressure 10 bar
•• Max absorbed current: •• Continuous service S1
– 7.5 A DG PED 3 •• Operates in a vertical position
– 10 A DG PED 5
•• P1 Maximum absorbed power:
– 1.0 kW DG PED 3 CLEAN WATER
– 1.5 kW DG PED 5
•• Protection IP X4 DOMESTIC USE
•• Factory set point 3 bar CIVIL USE

CHARACTERISTIC CURVES
60 60

max 5.5 bar


DG PED 3 DG PED 5
max 5.5 bar
50 50

40 40

Set point 3 bar Set point 3 bar


30 30
H (m)
H (m)

20 20

min 1 bar min 1 bar


10 10

00 00 10 20 30 40 50 60 70 80 90 100 110 120 130


10 20 30 40 50 60 70 80 90
Q (l/min) Q (l/min)

MODEL POWER MAX PERFORMANCES PERFORMANCES (ADJUSTABLE SET POINT)


P2 Q H Min. Set Point Set Point Stand. Setting Max. Set Point
Single-phase kW HP  l/min metres bar l/min bar l/min bar l/min

DG PED 3 0.75 1 5 – 80 55 – 10 1 35 – 80 3 5 – 58 5.5 5 – 30


IE3
DG PED 5 1.1 1.5 5 – 120 55 – 10 1 50 – 120 3 5 – 92 5.5 5 – 50

Q = Flow rate H = Total manometric head Tolerance of characteristic curves in compliance with EN ISO 9906 Grado 3B.
 Three phase motor efficiency class (IEC 60034-30-1)
DIMENSIONS (mm)

23 137 78 228 84

G 1”
G 1”
360°
360°

344
278

184
15 kg
35 130 35 Ø 40 Ø 40
200
160 66 180 144
274 390

CHARACTERISTIC CURVES FOR GROUPS OF TWO DG PED

60

max 5.5 bar


50

40

Set point 3 bar


H (m)

30 DG DG
PE PE DG
D3 D3 PED
20 + +D 5+
DG GP DG
PE ED PED
D3 5 5
min 1 bar
10

00 20 40 60 80 100 120 140 160 180 200 220 240 260


Q (l/min)

OPTIONAL ACCESSORIES
Connection kit for two
DG PED units

Electronic expansion Kit for wall-mounting a single Kit for wall-mounting a


circuit board DG PED group of two units

Pedrollo S.p.A.
Via Enrico Fermi, 7 - 37047 San Bonifacio (Verona) Italy
tel. +39 045 6136311 - fax +39 045 7614663
[email protected] - [email protected] - www.pedrollo.com Z-DPL90046UK

You might also like