0% found this document useful (0 votes)
98 views3 pages

Fire Protection System Proposal for ACompany

This document provides a financial offer for firefighting works at a factory in Port Said, Egypt. It lists 11 items with descriptions and quantities needed. The total cost is estimated at EGP 20,837,893 for supplying and installing equipment like fire pumps, hydrants, sprinklers, piping, cabinets, and more. Testing and approvals from the civil defense authority are included.

Uploaded by

Badr group
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
98 views3 pages

Fire Protection System Proposal for ACompany

This document provides a financial offer for firefighting works at a factory in Port Said, Egypt. It lists 11 items with descriptions and quantities needed. The total cost is estimated at EGP 20,837,893 for supplying and installing equipment like fire pumps, hydrants, sprinklers, piping, cabinets, and more. Testing and approvals from the civil defense authority are included.

Uploaded by

Badr group
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

F-Tech-03-04 Financial Offer

Project : Factory For ACompany Di Seta Egypt Subject : Firefighting WORKS


Location : Portsaid Sent by : Eng. Nada
Date : 7/12/2023 Ref :117-77 - 2023

Item DESCRIPTION UNIT QTY Unit Price Total

Firefighting Works
Factory For A Company Di Seta Egypt
Fire Protection System
1 Main fire pumps
TESTING, commissioning, startup, civil defense approval for the already installed
Fire fighting Pumps and install all necessary Valves, Fittings, and accessories, as
Specified, civil defense approval and consultant recommendation. having a capacity
of 1250
GPM&12 bar all requirements of NFPA 20 .
Desial Fire Pump-1 L.s 1 250,000 250,000
Electrical Fire Pump-1
Jockey pumps 100 gpm & 12
Install only, The price does not include the supply of pumps or any other
accessories needed for installation (Valves, Pipes, Fittings,.......etc)

2 External Network HPDE Piping


In linear meters Supply and installation of fire pipes of high-density polyethylene
Operating pressure 16 bar,
including special pieces of all kinds of elbows, methods, joints , thrusd blocks, main
air vent network 6" with its
chamber, washing valve6"with its chamber, all chamber boxes witht its covers and
complete succession with all their inclusions in accordance with the attached
specifications, provided that they are in accordance with
the European specifications EN/220/2003 and standard
specifications ISO4427/1996 carried out underground (buried) depth of not less than
1.2 meters for fire And be accredited and according to European and American
specifications and the price includes drilling and backfilling with clean soft sand and
tamping and everything necessary in accordance with the executive drawings and the
Egyptian code and technical specifications and industrial assets

2-1 6. 0" M 1,200 1,397 1,676,400


2.2 4. 0" M 100 719 71,900

3 Fire Extinguishers
Supply, install, connect, and test as specified and
according to drawings and as per civil defense approval, of dry powder manual,
portable, hand held, fire extinguishers to be installed all around the building, in
addition to CO2 manual fire extinguishers to be used in electrical and mechanical
room.
3-1 ABC-type(6 kg dry powder) NO 52 3,140 163,280
3-2 co2-Type (6 kg) NO 52 5,034 261,768
K-Type (6 kg ) used in kitchen &fire blanket NO 2 17,345 34,690

BG for Engineering Trading www.bg-eng.com


F-Tech-03-04 Financial Offer

4 Fire Hydrant
By number supply, installation, testing and operation of a vertical fire hydrant
diameter of 4 inches of flexible cast iron with two outlets and the diameter of the
outlet
65 mm (2.5 inches) and the entrance of the fire hydrant diameter 100 mm (4 inches)
conforming to the requirements of civil defense in accordance with the Egyptian
code for fire fighting and the item includes drilling in all types of soil and all that is
necessary to connect on the line feeding the tap as well as including the feeding
connection of pipes diameter 4 inches pressure not less than 10 bar and locking
valves diameter NO 20 41,768 835,360
4 inches Inside a surface box and equipped with Lagarde and the item including
backfilling using clean soft sand from the outside and tamping up to the ground level
and leveling the soil surface and returning the thing to the connection of all the
necessary according to the specifications all that is necessary in accordance with the
specifications and engineering drawings and instructions of the consultant and the
origins of the industry and
finish the work completely finished

5 Fire-department-connection
Supply and installation of a connection for the fire truck
Fire-department-connection (Quick Lacor connection forconnection to the fire truck)
is installed double 4 × 2.5 × 2.5 inch equipped with 2 male Morris entrances
complete with chain and cap installed visible on the wall of the building or the outer
fence and including a non- return valve 4" cast iron and fast lacure, and UL/FM must NO 1 69,045 69,045
be complete with lids, chain and all their contents in accordance with technical
specifications and industry assets.

6 Buried valves
Supply and installation gate valves with its lagred ,

proction, boxes and all its accessorries as specs and accordance with technical
specifications and industry assets.

6-1 6.0" NO 13 47,045 611,585


6-2 4.0" NO 20 32,841 656,820

7 Fire Hose Cabinet (FHC)


Supplying, installing, connecting and testing as specified
and according to drawings and as per civil defense approval, of fire hose station
consisting of 1' 1/2" brass angle valve, fire hose reel, fire hose 1 1/2" 30m long,
nozzle steel cabinet, 6 Kg portable fire extinguisher (dry powder) and all adapters NO 30 52,304 1,569,120
and fitting required for the complete assembly. (FHC-3)

8 Seamless black steel Piping


Supplying, installing, connecting and testing as specified and according to
drawings and as per civil
defense approval, and as per ASTM A53 Schedule 40
for fire protection seamless black steel piping system complete including pipes,
fitting, supports , hangers,
inserts and all coupling and adapters.

8-1 6.0" M 795 5,476 4,353,420


8-2 4.0" M 1,100 4,063 4,469,300
8-3 3.5" M 350 N/A
8-4 3.0" M 250 2,581 645,250
8-5 2.5 " M 432 2,036 879,552
8-6 2.0" M 662 1,368 905,616
8-7 1.5 " M 712 1,095 779,640
8-8 1.25 " M 985 895 881,575
8-9 1.0" M 3,512 722 2,535,664

9 Sprinklers
Automatic sprinklers
Supplying, installing, connecting and testing as
specified and according to drawings and as per civil defense approval".
9-1 PENDENT RECESSED SPRINKLER K=5.6 No 603 1,671 1,007,613
9-2 UPRIGHT SPRINKLER K=5.6 NO 2,131 652 1,389,412

BG for Engineering Trading www.bg-eng.com


F-Tech-03-04 Financial Offer

10 Automatic Air Vent


Supplying, installing, connecting and testing as specified and according to
NO 10 19,803 198,030
drawings and as per civil defense approval, automatic air vent 25 mm

11 Zone Control Station


Supplying, installing, connecting and testing as specified and according to drawings
and as per civil defense approval, Zone Control Station complete with OS& Y Gate
valve, Check valve, Water flow switch, pressure gauge, test and drain assembly and
all accessories.

11-1 6.0 " NO 8 100,392 803,136


11-2 4.0" NO 4 79,165 316,660
11-3 3.5" NO 2 N/A
11-4 3.0 " NO 4 66,865 267,460

12 ELECTRICAL & MCHA ROOMS& OTHERS:


Supplying, installing and testing as specified and according to drawings and as per
civil defense approval,
and all other accessories, miscellaneous and missing
items to complete the work.

12-1 12 KG AUTOMATIC DRY POWDER HOST IN


NO 20 6,746 134,920
CEILING
12-2 FIRE SEARCH FOR ELECTRICAL PANELS 2kg NO 40 16,483 659,320

13 HOOD suppression system


Supplying, installing and testing as specified and according to drawings and as
per civil defense approval,
Suppression system for Kitchen HOOD all items to complete the work. Price M2 2 313,110 626,220
to be one square meter
reference.

14 Automatic Gas Extinguishing System (FM-200)


Supply, installation and operation of the automatic fire fighting system using gas
(FM-200) to extinguish fires
in rooms according to the plans and the item includes providing all components of
the system with the link
with the fire alarm system, pipes, gas outlets, gas cylinders, control valves, sensors,
control panel and all that is necessary for installation in accordance with the
international plans and specifications NFPA, Egyptian

.standard specifications and civil defense requirements


14-1 IT Room - 40 kg NO 1 405,972 405,972
14-2 Archive room - 20 kg NO 1 310,824 310,824
14-3 Control and surveillance room- 30 kg NO 1 356,037 356,037

15 Automatic Gas Extinguishing System (CO2)


Supply, installation and testing of the CO2 system,
including all the inclusions of valves, cylinders, gas exit nozzles, warning system,
control panel, connected to the
main alarm face and cylinder scales, and the contractor
must submit all calculations for the weight of cylinders, pipe diameters and nozzles
according to the technical panels submitted Accredited by (FM/UL) to meet the
requirements of (NFPA) and civil defense specifications, including everything
necessary to finish the work with deification weights‫ ۔‬:

15-1 CO2 cylinders with a capacity of (45) kg each for low voltage rooms NO 1 281,194 281,194
15-2 CO2 cylinders with a capacity of (45) kg each for transformer rooms NO 1 281,194 281,194
15-3 CO2 cylinders with a capacity of (45) kg each for generator rooms NO 1 281,194 281,194

Grand Total 28,969,171

Technical Office Engineer Technical Office Manager


Eng.Nada Kamel Eng.Hassan Badr

BG for Engineering Trading www.bg-eng.com