Ellis Electrical Brochure March21 v.2
Ellis Electrical Brochure March21 v.2
KABEL S C H E L L E N
E LDA X
K ABE LV E RL E G E
S Y S T EME & C O
Î Our products are used by customers in over 40 countries
HOLDING POWER to protect the electrical supply to vital operations and
ensure systems keep running safely and securely in the
– TRIED, TESTED, event of a short circuit
We are widely recognised Î Our in-house engineering capabilities allow for constant
product development and innovation, and the creation of
as the global leader in the bespoke solutions for individual project specifications
design and manufacture Î Our manufacturing headquarters in North Yorkshire,
England are ISO9001, ISO14001 and ISO45001
of safety critical electrical certified and all our cable cleats are manufactured to
cable cleats and fixing IEC61914:2015 and short circuit tested as standard prior
to being brought to market. We also offer project specific
solutions. short circuit testing
02
Alpha™ 06
Vulcan+™ 08
Vulcan+™ Quad 10
Emperor™ Trefoil 14
Emperor™ Single 16
Flexi-Strap™ 18
Protect™ 20
Trident® 22
Colossus™ 24
Centaur® 26
Centaur® Strap 28
Atlas™ 32
Vari-Cleat ™
34
No Bolts Cleat™ 36
1A 38
2A 40
1F 42
2F+ 44
Phoenix® 46
Matrix™ 48
Bespoke 49
Mk2 Hanger 50
Convex Hanger 51
Pegasus 52
Jointers Tools 63
Ladder Adaptors 65
EP2019/01
03
QUICK SELECTION GUIDE
Alpha™ page Vulcan+™ page Vulcan+™ page Vulcan+™ page Emperor™ page
06 08 Quad 10 Twist Foot 12 Trefoil 14
Emperor™ page Flexi-strap™ page Protect™ page Trident™ page Colossus™ page
Single 16 18 20 22 24
Centaur ® page Centaur ® page Cable Guide page Atlas™ page Vari-cleat™ page
26 Strap 28 Clamp™ 30 32 34
No Bolts page One & Two Hole page One & Two Hole page Phoenix® page Matrix™ page
Cleat™ 36 Cableclamps - 38 Cableclamps - 42 46 48
Aluminium Non Metallic
Mk2 Hanger page Convex Hanger page Pegasus page Triplex Cable page Single Bolt page
50 51 Hanger 52 Surround 54 Fixing Clamp 56
04
GRAPH BELOW IS FORFOR TREFOIL ONLY
200
180
160
140
Colossus
Emperor
120
Peak current (kA)
Vulcan+
Alpha
100
Trident
80
60
40
20
0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180
Cable Diameter (mm)
200
180
160
140
Colossus
Emperor
120
Peak current (kA)
Vulcan+
Alpha
100
Trident
80
60
40
20
0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180
Cable Diameter (mm)
The above graphs can be used to provide a general indication of relative cleat strengths, for accurate cleat specification
refer to the Ellis online calculator or black book. Also check product datasheets for actual short circuit test results.
05
ALPHA ™
CABLE RANGE
DIMENSIONS (mm)
PART NO. PART NO. TREFOIL WEIGHT
ALUMINIUM BASE POLYMER BASE MIN Ø MAX Ø FIXING HOLES (g)
W H D
(mm) (mm) (D1)
ALP01-AN0 ALP01-AN1 23.2 25.1 76 93 48.5 1 x M10 168
ALP02-AN0 ALP02-AN1 25.1 27.1 79 96 48.5 1 x M10 178
ALP03-AN0 ALP03-AN1 27.1 29.3 82 101 48.5 1 x M10 185
ALP04-AN0 ALP04-AN1 29.3 31.7 86 105 48.5 1 x M10 195
ALP05-AN0 ALP05-AN1 31.7 34.2 91 110 48.5 1 x M10 205
ALP06-AN0 ALP06-AN1 34.2 37.0 96 116 48.5 1 x M10 217
ALP07-AN0 ALP07-AN1 37.0 40.0 101 121 48.5 1 x M10 229
ALP08-AN0 ALP08-AN1 40.0 43.2 106 127 48.5 1 x M10 241
ALP09-AN0 ALP09-AN1 43.2 46.7 113 134 48.5 1 x M10 255
ALP10-AN0 ALP10-AN1 46.7 50.5 119 141 48.5 1 x M10 272
ALP11-AN0 ALP11-AN1 50.5 54.6 127 148 48.5 1 x M10 288
ALP12-AN0 ALP12-AN1 54.6 59.0 135 156 48.5 1 x M10 307
ALP13-AN0 ALP13-AN1 59.0 63.8 144 165 48.5 1 x M10 327
ALP14-AN0 ALP14-AN1 63.8 69.0 153 175 48.5 1 x M10 348
ALP15-AN0 ALP15-AN1 69.0 74.6 163 186 48.5 1 x M10 372
ALUMINIUM BASE
POLYMER BASE
(WITH POLYESTER COATED FRAME)
06
TESTING SUMMARY
Alpha Cleats have been tested in line with the International Standard ‘Cable Cleats for Electrical Installations’ IEC
61914:2015. Typical results are detailed below, please note that these testing values are maximums and safety
factors appropriate to your application should be used:
CLASSIFICATION UNITS /
PROPERTY TEST DATA
CLAUSE IEC 61914 CLASSIFICATION
HORIZONTAL - 500N
LATERAL LOAD RATING 6.4.2, 9.3 NEWTONS (N)
VERTICAL - 500N
LONDON UNDERGROUND
Alpha Cable Cleats are compliant with
the requiremnts of LUL-1085. Product
Conduit & cable hardware 4CG8 with
register number 360.
AH-2 & wet locations. Listed sizes:
ALP01-AN0 to ALP15-AN0.
This information is subject to change without notice. The information provided has been generated in laboratory conditions, as such results in use may vary.
07
VULCAN+ ™
08
TESTING SUMMARY
Vulcan+ Cleats have been tested in line with the International Standard ‘Cable Cleats for Electrical Installations’
IEC 61914:2015. Typical results are detailed below, please note that these testing values are maximums and safety
factors appropriate to your application should be used:
CLASSIFICATION UNITS /
PROPERTY TEST DATA
CLAUSE IEC 61914 CLASSIFICATION
150N - TREFOIL
AXIAL LOAD RATING 6.4.3, 9.4 NEWTONS (N)
45N - SINGLE
HORIZONTAL - 200N
LATERAL LOAD RATING 6.4.2, 9.3 NEWTONS (N)
VERTICAL -650N
134kA
RESISTANCE TO CLEATS AT 300MM INTERVALS (REPORT No. PDL-18.122.1)
ELECTROMECHANICAL FORCE 6.4, 6.4.5, 9.5 (WITHSTANDING MORE THAN ONE
(SHORT CIRCUIT TESTING) SHORT CIRCUIT)
CABLE OD= Ø36mm
115kA
RESISTANCE TO CLEATS AT 600MM INTERVALS (REPORT No. PDL-16.164.3)
ELECTROMECHANICAL FORCE 6.4, 6.4.5, 9.5 (WITHSTANDING MORE THAN ONE
(SHORT CIRCUIT TESTING) SHORT CIRCUIT)
CABLE OD= Ø36mm
LONDON UNDERGROUND
Vulcan+ Cable Cleats are compliant
with the requiremnts of LUL-1085.
Conduit & cable hardware 4CG8 with
Product register number 361.
AH-2 & wet locations. Listed sizes:
VRT+00 to VRT+18.
This information is subject to change without notice. The information provided has been generated in laboratory conditions, as such results in use may vary.
09
VULCAN+ QUAD ™
10
TESTING SUMMARY
Vulcan+ Cleats have been tested in line with the International Standard ‘Cable Cleats for Electrical Installations’
IEC 61914:2015. Typical results are detailed below, please note that these testing values are maximums and safety
factors appropriate to your application should be used:
CLASSIFICATION UNITS /
PROPERTY TEST DATA
CLAUSE IEC 61914 CLASSIFICATION
HORIZONTAL - 100N
LATERAL LOAD RATING 6.4.2, 9.3 NEWTONS (N)
VERTICAL -350N
134kA
RESISTANCE TO CLEATS AT 300MM (REPORT No. PDL-
ELECTROMECHANICAL FORCE 6.4, 6.4.5, 9.5 INTERVALS 18.122.1)
(WITHSTANDING MORE THAN ONE
(SHORT CIRCUIT TESTING)
SHORT CIRCUIT) CABLE OD= Ø36mm
(VRT+)
115kA
RESISTANCE TO CLEATS AT 600MM (REPORT No. PDL-
ELECTROMECHANICAL FORCE 6.4, 6.4.5, 9.5 INTERVALS 16.164.3)
(WITHSTANDING MORE THAN ONE
(SHORT CIRCUIT TESTING)
SHORT CIRCUIT) CABLE OD= Ø36mm
(VRT+)
LONDON UNDERGROUND
Vulcan+ Cable Cleats are compliant with
the requiremnts of LUL-1085. Product
Conduit & cable hardware 4CG8 with
AH-2 & wet locations. Listed sizes:
register number 361.
VRQ+01 to VRQ+09.
This information is subject to change without notice. The information provided has been generated in laboratory conditions, as such results in use may vary.
11
VULCAN+ TWIST FOOT ™
1) Lower the cleat through the 2) Once lowered twist the 3) Tighten the M10 bolt in the base of the
gap in the channel. cleat 90°. cleat.
4) As the bolt is tightened 5) The cleat is now securley fastened to the structure and
the channel nut will move is ready to accept the cables.
up the twist foot base and
grip onto the channel.
This information is subject to change without notice. The information provided has been generated in laboratory conditions, as such results in use may vary.
13
EMPEROR ™
TREFOIL
Stainless Steel Cable Cleats
Patent No. UK Patent GB 233 9237
14
TESTING SUMMARY
Emperor Cleats have been tested in line with the International Standard ‘Cable Cleats for Electrical Installations’
IEC 61914:2015. Typical results are detailed below, please note that these testing values are maximums and safety
factors appropriate to your application should be used:
CLASSIFICATION UNITS /
PROPERTY TEST DATA
CLAUSE IEC 61914 CLASSIFICATION
HORIZONTAL - 650N
LATERAL LOAD RATING 6.4.2, 9.3 NEWTONS (N)
VERTICAL -1000N
195kA
RESISTANCE TO CLEATS AT 300MM INTERVALS (REPORT No. PDL-09.098.2)
ELECTROMECHANICAL FORCE 6.4, 6.4.4, 9.5 (WITHSTANDING ONE SHORT
(SHORT CIRCUIT TESTING) CIRCUIT) CABLE OD= Ø38mm
(IEC 61914:2009)
149kA
RESISTANCE TO CLEATS AT 600MM INTERVALS (REPORT No. PDL-17.137.4)
ELECTROMECHANICAL FORCE 6.4, 6.4.5, 9.5 (WITHSTANDING MORE THAN ONE
(SHORT CIRCUIT TESTING) SHORT CIRCUIT)
CABLE OD= Ø36mm
LONDON UNDERGROUND
Emperor Cable Cleats are compliant
with the requiremnts of LUL-1085.
Conduit & cable hardware 4CG8 with
Product register number 362.
AH-2 & wet locations. Listed sizes:
ER19-23 to ER82-88.
This information is subject to change without notice. The information provided has been generated in laboratory conditions, as such results in use may vary.
15
EMPEROR ™
SINGLE
Stainless Steel Cable Cleats
Patent No. UK Patent GB 233 9237
16
TESTING SUMMARY
Emperor Cleats have been tested in line with the International Standard ‘Cable Cleats for Electrical Installations’
IEC 61914:2015. Typical results are detailed below, please note that these testing values are maximums and safety
factors appropriate to your application should be used:
CLASSIFICATION UNITS /
PROPERTY TEST DATA
CLAUSE IEC 61914 CLASSIFICATION
HORIZONTAL - 650N
LATERAL LOAD RATING 6.4.2, 9.3 NEWTONS (N)
VERTICAL -1000N
195kA
RESISTANCE TO (REPORT No. PDL-09.098.2)
CLEATS AT 300MM INTERVALS
ELECTROMECHANICAL FORCE 6.4, 6.4.4, 9.5 (WITHSTANDING ONE SHORT
(SHORT CIRCUIT TESTING)
CIRCUIT) CABLE OD= Ø38mm
(EMPEROR TREFOIL)
(IEC 61914:2009)
RESISTANCE TO 149kA
CLEATS AT 600MM INTERVALS (REPORT No. PDL-17.137.4)
ELECTROMECHANICAL FORCE 6.4, 6.4.5, 9.5 (WITHSTANDING MORE THAN ONE
(SHORT CIRCUIT TESTING)
SHORT CIRCUIT)
(EMPEROR TREFOIL) CABLE OD= Ø36mm
LONDON UNDERGROUND
Emperor Cable Cleats are compliant
with the requiremnts of LUL-1085.
Conduit & cable hardware 4CG8
Product register number 362.
with AH-2 & wet locations. Listed sizes:
ES32-39 to ES94-118.
This information is subject to change without notice. The information provided has been generated in laboratory conditions, as such results in use may vary.
17
FLEXI-STRAP ™
18
TESTING SUMMARY
Flexi-Straps have been tested in line with the International Standard ‘Cable Cleats for Electrical Installations’ IEC
61914:2015. Typical results are detailed below, please note that these testing values are maximums and safety
factors appropriate to your application should be used:
CLASSIFICATION
UNITS / TEST DATA TEST DATA
PROPERTY CLAUSE
CLASSIFICATION (STANDARD DUTY) (HEAVY DUTY)
IEC 61914
TEMP. FOR
PERMAMENT 6.2 °C -40 to +60 -40 to +60
APPLICATION
316L STAINLESS 316L STAINLESS
CORROSION
6.5.2.2 HIGH STEEL HAS≥16% STEEL HAS≥16%
RESISTANCE
CHROMIUM CHROMIUM
FLAME PROPAGATION
10.0, 10.1 APPLICATION TIME ≥30s PASS PASS
TEST
RESISTANCE TO CLEATS AT 300MM 134kA (REPORT No.
ELECTROMECHANICAL INTERVALS PDL-18.122.3)
6.4, 6.4.4, 9.5 -
FORCE (WITHSTANDING ONE SHORT
(SHORT CIRCUIT TESTING) CIRCUIT) CABLE OD= Ø36mm
156kA
114kA
RESISTANCE TO CLEATS AT 600MM (REPORT No.
(REPORT No.
ELECTROMECHANICAL INTERVALS ZKU-15-204)
6.4, 6.4.5, 9.5 PDL-18.122.4)
FORCE (WITHSTANDING MORE THAN
(SHORT CIRCUIT TESTING) ONE SHORT CIRCUIT) CABLE OD= Ø38mm
CABLE OD= Ø36mm
(IEC 61914:2009)
HORIZONTAL - 2250N
LATERAL LOAD RATING 6.4.2, 9.3 NEWTONS (N)
VERTICAL -2250N
134kA
RESISTANCE TO CLEATS AT 300MM
(REPORT No.
ELECTROMECHANICAL INTERVALS
6.4, 6.4.5, 9.5 PDL-18.071.6)
FORCE (WITHSTANDING MORE THAN
(SHORT CIRCUIT TESTING) ONE SHORT CIRCUIT)
CABLE OD= Ø36mm
94kA
RESISTANCE TO CLEATS AT 600MM
(REPORT No.
ELECTROMECHANICAL INTERVALS
6.4, 6.4.5, 9.5 PDL-18.071.5)
FORCE (WITHSTANDING MORE THAN
(SHORT CIRCUIT TESTING) ONE SHORT CIRCUIT)
CABLE OD= Ø36mm
INSTALLATION INFORMATION:
Flexi-Strap is installed by wrapping multiple layers of stainless steel strip around the cable. It is tightened and locked in place
using a patented buckle and spindle design. Standard duty straps are wrapped twice around the cables and heavy duty straps
are wrapped three times. For more information please refer to the product installation instructions or alternatively the videos
section of our website.
A special drive socket to turn the spindle is supplied with every 50 straps ordered, the socket can attach to a standard 1/4”
or 6mm ratchet handle. Drive sockets can be ordered seperatley using the part number FS-T001-4. Although the FS-T001-4
can speed up installation, standard tools also can be used.
This information is subject to change without notice. The information provided has been generated in laboratory conditions, as such results in use may vary.
19
PROTECT ™
Retention Strap
UK Design Reg No. 355854
TESTING SUMMARY
CLASSIFICATION UNITS /
PROPERTY TEST DATA
CLAUSE IEC 61914 CLASSIFICATION
This information is subject to change without notice. The information provided has been generated in laboratory conditions, as such results in use may vary.
20
21
TRIDENT ®
22
TESTING SUMMARY
Trident Cleats have been tested in line with the International Standard ‘Cable Cleats for Electrical Installations’ IEC
61914:2015. Typical results are detailed below, please note that these testing values are maximums and safety factors
appropriate to your application should be used:
CLASSIFICATION UNITS /
PROPERTY TEST DATA
CLAUSE IEC 61914 CLASSIFICATION
HORIZONTAL - 2250N
LATERAL LOAD RATING 6.4.2, 9.3 NEWTONS (N)
VERTICAL -2250N
134kA
RESISTANCE TO CLEATS AT 300MM INTERVALS
(REPORT No. PDL-18.071.6)
ELECTROMECHANICAL FORCE 6.4, 6.4.5, 9.5 (WITHSTANDING MORE THAN ONE
(SHORT CIRCUIT TESTING) SHORT CIRCUIT)
CABLE OD= Ø36mm
94kA
RESISTANCE TO CLEATS AT 600MM INTERVALS
(REPORT No. PDL-18.071.5)
ELECTROMECHANICAL FORCE 6.4, 6.4.5, 9.5 (WITHSTANDING MORE THAN ONE
(SHORT CIRCUIT TESTING) SHORT CIRCUIT)
CABLE OD= Ø36mm
This information is subject to change without notice. The information provided has been generated in laboratory conditions, as such results in use may vary.
23
COLOSSUS ™
Community Design
Reg. No. 001927583
24
TESTING SUMMARY
Colossus Cleats have been tested in line with the International Standard ‘Cable Cleats for Electrical Installations’
IEC 61914:2015. Typical results are detailed below, please note that these testing values are maximums and safety
factors appropriate to your application should be used:
CLASSIFICATION UNITS /
PROPERTY TEST DATA
CLAUSE IEC 61914 CLASSIFICATION
170kA
RESISTANCE TO CLEATS AT 300MM INTERVALS
(REPORT No. PDL-18.122)
ELECTROMECHANICAL FORCE 6.4, 6.4.4, 9.5 (WITHSTANDING ONE SHORT
(SHORT CIRCUIT TESTING) CIRCUIT)
CABLE OD= Ø36mm
150kA
RESISTANCE TO CLEATS AT 600MM INTERVALS
(REPORT No. PDL-16.164.2)
ELECTROMECHANICAL FORCE 6.4, 6.4.5, 9.5 (WITHSTANDING MORE THAN ONE
(SHORT CIRCUIT TESTING) SHORT CIRCUIT)
CABLE OD= Ø36mm
104kA
RESISTANCE TO CLEATS AT 7.8M INTERVALS (REPORT No. ZKU-12-179)
ELECTROMECHANICAL FORCE 6.4, 6.4.5, 9.5 (WITHSTANDING MORE THAN ONE CABLE OD= Ø70mm
(SHORT CIRCUIT TESTING) SHORT CIRCUIT) (WITH PROTECT STRAPS EVERY
1.3m - BASED ON IEC61914:2009)
This information is subject to change without notice. The information provided has been generated in laboratory conditions, as such results in use may vary.
25
CENTAUR ®
26
TESTING SUMMARY
Centaur cable saddles have been tested in line with the International Standard ‘Cable Cleats for Electrical
Installations’ As IEC 61914 is part of the low voltage directive it is not possible to follow the standard exactly and
thus deviations have been made in areas. Typical results are detailed below, please note that these testing values
are maximums and safety factors appropriate to your application should be used:
CLASSIFICATION UNITS /
PROPERTY TEST DATA
CLAUSE IEC 61914 CLASSIFICATION
163kA
RESISTANCE TO CENTAUR CLEATS AT 8.4M (REPORT No.
ELECTROMECHANICAL FORCE 6.4, 6.4.4, 9.5 KEMA-313-08)
(SHORT CIRCUIT TESTING)
WITH STRAPS AT MIDPOINTS
PHASE SPACING = 800mm
27
CENTAUR ®
INTERMEDIATE STRAP
Aluminium cable spacer
Î DESIGNED TO RESTRAIN CABLES DURING A SHORT CIRCUIT FAULT AND MAINTAIN PHASE SPACING
UNDER NORMAL OPERATING CONDITIONS
Î MANUFACTURED IN 6000 SERIES ALUMINIUM
Î TYPICAL SIZES RANGE FROM Ø100 - Ø162MM HOWEVER SPECIALS CAN BE PROVIDED ON
REQUEST
Î EACH CLAMP CAN PIVOT ABOUT THE JOINING BAR TO ACCOMMODATE FOR DIFFERENTIAL CABLE
MOVEMENT. FIXED VERSIONS CAN BE SUPPLIED ON REQUEST.
Î SHORT CIRCUIT TESTED BASED ON IEC 61914
28
TESTING SUMMARY
Centaur cable saddles have been tested in line with the International Standard ‘Cable Cleats for Electrical
Installations’ As IEC 61914 is part of the low voltage directive it is not possible to follow the standard exactly and
thus deviations have been made in areas. Typical results are detailed below, please note that these testing values
are maximums and safety factors appropriate to your application should be used:
CLASSIFICATION UNITS /
PROPERTY TEST DATA
CLAUSE IEC 61914 CLASSIFICATION
This information is subject to change without notice. The information provided has been generated in laboratory conditions, as such results in use may vary.
29
CABLE GUIDE CLAMP ™
30
TESTING SUMMARY
Cable Guide Clamp has been tested in line with the International Standard ‘Cable Cleats for Electrical Installations’
IEC 61914:2015. As IEC 61914 is part of the low voltage directive it is not possible to follow the standard exactly and
thus deviations have been made in areas. Typical results are detailed below, please note that these testing values
are maximums and safety factors appropriate to your application should be used:
CLASSIFICATION UNITS /
PROPERTY TEST DATA
CLAUSE IEC 61914 CLASSIFICATION
This information is subject to change without notice. The information provided has been generated in laboratory conditions, as such results in use may vary.
31
ATLAS ™
DIMENSIONS (mm)
CABLE TWO BOLT BASE FIXING SINGLE BOLT BASE FIXING FRAMING CHANNEL BASE FIXING WEIGHT
PART NO.
RANGE (g)
FIXING HOLES FIXING HOLES FIXING HOLES
W H D P W H D W H D
(D1) (D1) (D1)
AR2-A31-XX 24-26 170 121 54 150 2 x M10 144 130 54 1 x M10 144 125 54 1 x M10 930
AR2-A32-XX 26-30 170 122 54 150 2 x M10 144 130 54 1 x M10 144 125 54 1 x M10 930
AR2-A33-XX 30-35 170 133 54 150 2 x M10 157 141 54 1 x M10 157 136 54 1 x M10 970
AR2-A34-XX 35-40 170 134 54 150 2 x M10 158 142 54 1 x M10 158 137 54 1 x M10 930
AR3-A35-XX 40-45 198 158 54 175 2 x M10 185 165 54 1 x M10 185 160 54 1 x M10 1200
AR3-A36-XX 45-50 198 160 54 175 2 x M10 187 167 54 1 x M10 187 162 54 1 x M10 1200
AR4-A37-XX 50-55 214 174 54 200 2 x M10 204 182 54 1 x M12 204 177 54 1 x M12 1300
AR4-A38-XX 55-60 214 179 54 200 2 x M10 210 187 54 1 x M12 210 182 54 1 x M12 1300
AR4-A39-XX 60-66 214 185 54 200 2 x M10 217 193 54 1 x M12 217 188 54 1 x M12 1300
AR5-A61-XX 66-71 250 225 54 225 2 x M10 254 225 54 1 x M12 254 220 54 1 x M12 1800
AR5-A62-XX 71-76 250 226 54 225 2 x M10 255 226 54 1 x M12 255 221 54 1 x M12 1800
AR5-A63-XX 76-82 250 230 54 225 2 x M10 260 230 54 1 x M12 260 225 54 1 x M12 1800
AR8-A64-XX 82-92 285 250 54 225 2 x M10 N/A N/A 2100
AR8-A65-XX 92-102 285 250 54 225 2 x M10 N/A N/A 1900
TWO BOLT BASE FIXING SINGLE BOLT BASE FIXING FRAMING CHANNEL BASE FIXING
32
SELECTION TABLE FOR SINGLE FORMATIONS
DIMENSIONS (mm)
CABLE TWO BOLT BASE FIXING SINGLE BOLT BASE FIXING FRAMING CHANNEL BASE FIXING WEIGHT
PART NO.
RANGE FIXING FIXING FIXING (g)
W H D P W H D W H D
HOLES (D1) HOLES (D1) HOLES (D1)
AR2-A11-XX 38-41 170 128 54 150 2 x M10 144 136 54 1 x M10 144 131 54 1 x M10 950
AR2-A12-XX 41-47 170 129 54 150 2 x M10 144 136 54 1 x M10 144 131 54 1 x M10 930
AR2-A13-XX 47-55 170 140 54 150 2 x M10 157 147 54 1 x M10 157 142 54 1 x M10 940
AR2-A14-XX 55-63 170 141 54 150 2 x M10 158 148 54 1 x M10 158 143 54 1 x M10 930
AR3-A15-XX 63-70 198 164 54 175 2 x M10 185 172 54 1 x M10 185 167 54 1 x M10 1200
AR3-A16-XX 70-79 198 166 54 175 2 x M10 187 173 54 1 x M10 187 168 54 1 x M10 1200
AR4-A17-XX 79-87 214 180 54 200 2 x M10 204 188 54 1 x M12 204 183 54 1 x M12 1300
AR4-A18-XX 87-95 214 186 54 200 2 x M10 210 193 54 1 x M12 210 188 54 1 x M12 1300
AR4-A19-XX 95-104 214 192 54 200 2 x M10 217 199 54 1 x M12 217 197 54 1 x M12 1300
AR5-A51-XX 104-112 250 231 54 225 2 x M10 254 231 54 1 x M12 254 226 54 1 x M12 1700
AR5-A52-XX 112-120 250 232 54 225 2 x M10 255 232 54 1 x M12 255 227 54 1 x M12 1700
AR5-A53-XX 120-130 250 237 54 225 2 x M10 260 237 54 1 x M12 260 232 54 1 x M12 1700
For full part number please replace ‘XX’ with the following.:
TB = TWO BOLT BASE FIXING
SB = SINGLE BOLT BASE FIXING
FC = FRAMING CHANNEL BASE FIXING
TESTING SUMMARY
Atlas Cleats have been tested in line with the International Standard ‘Cable Cleats for Electrical Installations’ IEC
61914:2015. Typical results are detailed below, please note that these testing values are maximums and safety
factors appropriate to your application should be used:
CLASSIFICATION UNITS /
PROPERTY TEST DATA
CLAUSE IEC 61914 CLASSIFICATION
120kA
RESISTANCE TO CLEATS AT 300MM INTERVALS (REPORT No.
ELECTROMECHANICAL FORCE 6.4, 6.4.4, 9.5 (WITHSTANDING ONE SHORT PDL-18.122.7)
(SHORT CIRCUIT TESTING) CIRCUIT)
CABLE OD= Ø36mm
This information is subject to change without notice. The information provided has been generated in laboratory conditions, as such results in use may vary.
33
VARI-CLEAT ™
TESTING SUMMARY
Vari-Cleat has been tested in line with the International Standard ‘Cable Cleats for Electrical Installations’ IEC
61914:2015. Typical results are detailed below, please note that these testing values are maximums and safety
factors appropriate to your application should be used:
34
CABLE RANGE WITHOUT CABLE RANGE SINGLE
DIMENSIONS (mm) FIXING HOLES
PART NO. LINER WITH LINER WEIGHT (g)
(D1 & D2)
TREFOIL SINGLE TREFOIL SINGLE W H D P
VC-AN1-XXX 21-24 36-43 19-22 31-38 82 80 74 25 2 x M8 373
VC-AN2-XXX 22-26 41-48 21-24 36-43 82 84 74 25 2 x M8 373
VC-AN3-XXX 24-28 44-51 23-26 39-46 83 88 74 25 2 x M8 373
VC-AN4-XXX 26-30 49-54 25-29 44-51 86 92 74 25 2 x M8 373
VC-BN1-XXX 29-33 51-59 27-31 46-54 97 94 74 25 2 x M8 430
VC-BN2-XXX 30-35 55-63 29-33 50-58 97 97 74 25 2 x M8 430
VC-BN3-XXX 32-37 60-68 30-36 55-63 100 101 74 25 2 x M8 430
VC-BN4-XXX 34-38 64-70 33-38 59-68 104 105 74 25 2 x M8 430
VC-CN1-XXX 37-42 68-76 35-40 63-71 117 105 76 25 2 x M8 490
VC-CN2-XXX 39-44 72-81 37-42 67-76 117 109 76 25 2 x M8 490
VC-CN3-XXX 42-47 76-85 39-45 71-80 118 115 76 25 2 x M8 490
VC-CN4-XXX 44-48 81-87 42-47 76-86 124 121 76 50 2 x M8 490
VC-DN1-XXX 47-53 86-96 47-51 81-91 138 126 78 50 2 x M8 + 1 x M10 610
VC-DN2-XXX 50-56 91-100 49-54 86-95 141 132 78 50 2 x M8 + 1 x M10 610
VC-DN3-XXX 54-59 96-105 52-57 91-100 147 138 78 50 2 x M8 + 1 x M10 610
VC-DN4-XXX 56-60 101-106 55-60 96-106 153 144 78 75 2 x M8 + 1 x M10 610
VC-EN1-XXX 59-63.5 105-112 58-62 100-107 163 147 80 75 2 x M8 + 1 x M10 730
VC-EN2-XXX 62-67 111-118 61-66 106-113 167 154 80 75 2 x M8 + 1 x M10 730
VC-EN3-XXX 65-70 118-125 64-69 113-120 174 160 80 75 2 x M8 + 1 x M10 730
VC-EN4-XXX 68-74 125-132 67-73 120-127 181 167 80 75 2 x M8 + 1 x M10 730
VC-FN1-XXX 71-76 125-140 69-74 120-135 187 170 82 90 3 x M12 880
VC-FN2-XXX 74-80 132-145 72-78 128-140 194 177 82 90 3 x M12 880
VC-FN3-XXX 78-84 139-152 76-82 134-147 201 185 82 90 3 x M12 880
VC-FN4-XXX 82-88 148-160 80-86 143-155 210 193 82 90 3 x M12 880
VC-GN1-XXX 84-91 145-160 82-89 140-155 217 197 82 114 3 x M12 970
VC-GN2-XXX 88-95 155-170 86-93 150-165 225 205 82 114 3 x M12 970
VC-GN3-XXX 92-99 165-180 90-97 160-175 233 213 82 114 3 x M12 970
VC-GN4-XXX 96-103 175-190 94-101 170-185 240 221 82 114 3 x M12 970
VC-HN1-XXX 98-106 170-190 96-104 165-185 247 229 84 136 3 x M12 1170
VC-HN2-XXX 102-110 180-200 100-108 175-195 255 237 84 136 3 x M12 1170
VC-HN3-XXX 106-114 190-205 104-112 185-200 263 245 84 136 3 x M12 1170
VC-HN4-XXX 110-118 200-215 108-116 195-210 271 252 84 136 3 x M12 1170
This information is subject to change without notice. The information provided has been generated in laboratory conditions, as such results in use may vary.
35
NO BOLTS CLEAT ™
Patent Pending
(Application Number 1804174.9)
NOTE: THE CLEAT RANGE IS COVERED BY A SET OF INSERTS THAT SIT INSIDE THE MAIN BODY, FOR THE TWIST FOOT VERSION ADD A 'TF' SUFFIX E.G.
THEREFORE ALL OUTSIDE DIMENSIONS ARE THE SAME. *NBC45-55 DOES NOT USE INSERTS. NBC18-22TF
36
TESTING SUMMARY
No Bolts Cleat has been tested in line with the International Standard of ‘Cable Cleats for Electrical
Installations’ IEC 61914: 2015. Typical results below:
CLASSIFICATION UNITS /
PROPERTY TEST DATA
CLAUSE IEC 61914 CLASSIFICATION
71kA
(REPORT No. PDL-16.106)
RESISTANCE TO CLEATS AT 300MM INTERVALS TESTED IN STACKED
ELECTROMECHANICAL FORCE 6.4, 6.4.5, 9.5 (WITHSTANDING MORE THAN ONE
SHORT CIRCUIT)
FORMATION
(SHORT CIRCUIT TESTING)
PHASE SPACING = 75mm
CABLE OD= Ø36mm
NO BOLTS CLEAT IS A NETWORK RAIL APPROVED PRODUCT. EXAMPLE PADS NUMBER (NBC45-55): 011/120134
This information is subject to change without notice. The information provided has been generated in laboratory conditions, as such results in use may vary.
37
1A CABLE CLAMPS
Cast aluminium clamp
38
TESTING SUMMARY
1A Clamps have been tested in line with the International Standard ‘Cable Cleats for Electrical Installations’ IEC
61914:2015. Typical results are detailed below, please note that these testing values are maximums and safety factors
appropriate to your application should be used:
CLASSIFICATION UNITS /
PROPERTY TEST DATA
CLAUSE IEC 61914 CLASSIFICATION
70.8kA
(REPORT No.
RESISTANCE TO CLEATS AT 600MM INTERVALS PDL-15.025.2)
ELECTROMECHANICAL FORCE 6.4, 6.4.5, 9.5 (WITHSTANDING MORE THAN ONE
(SHORT CIRCUIT TESTING) SHORT CIRCUIT) (IEC 61914:2009)
PHASE SPACING = 100mm
CABLE OD= Ø39mm
This information is subject to change without notice. The information provided has been generated in laboratory conditions, as such results in use may vary.
39
2A CABLE CLAMPS
Cast aluminium clamp
CABLE RANGE
CABLE RANGE LINER DIMENSIONS (mm)
WITH LINER LATERAL LATERAL
PART THICK- WEIGHT AXIAL
LOAD - LOAD -
NO. MIN Ø MAX Ø NESS MIN Ø MIN Ø (g) LOAD
W H D P Ø HORIZONTAL VERTICAL
(mm) (mm) (mm) (mm) (mm)
2A-07N 38 46 3 32 40 94 48 49 68 2 x M10 174 800N 12.5kN 25kN
2A-08N 46 51 3 40 45 104 54 49 79 2 x M10 214 800N 12.5kN 25kN
2A-09N 51 57 3 45 51 105 61 49 79 2 x M10 224 800N 12.5kN 25kN
2A-10N 57 64 3 51 58 105 68 49 79 2 x M10 234 800N 12.5kN 25kN
2A-11N 64 70 3 58 64 133 74 64 106 2 x M10 360 800N 12.5kN 25kN
2A-1200N 70 76 3 64 70 133 80 64 106 2 x M10 376 800N 12.5kN 25kN
2A-1201N 76 83 3 70 77 133 87 64 106 2 x M10 388 800N 12.5kN 25kN
2A-1202N 83 90 3 77 84 133 94 64 106 2 x M10 392 800N 12.5kN 25kN
2A-131N 90 97 4 82 89 154 101 76 126 2 x M10 520 800N 12.5kN 25kN
2A-132N 97 105 4 89 97 154 109 76 126 2 x M10 524 800N 12.5kN 25kN
2A-141N 105 112 4 97 104 165 118 76 135 2 x M10 590 800N 12.5kN 25kN
2A-142N 112 120 4 104 112 173 124 76 143 2 X M10 642 800N 12.5kN 25kN
2A-151N 120 128 5 110 118 196 148 125 168 2 X M12 1700 5.5kN 20kN 50kN
2A-152N 128 135 5 118 125 203 158 125 176 2 X M12 1840 5.5kN 20kN 50kN
2A-161N 135 144 5 125 134 222 168 150 190 2 X M16 2633 6kN 35kN 60kN
2A-162N 144 152 5 134 142 232 179 150 200 2 X M16 2856 6kN 35kN 60kN
2A-171N 152 160 5 142 150 242 190 150 210 2 X M16 3089 6kN 35kN 60kN
2A-172N 160 168 5 150 158 252 201 150 220 2 X M16 3332 6kN 35kN 60kN
40
TESTING SUMMARY
2A Clamps have been tested in line with the International Standard ‘Cable Cleats for Electrical Installations’ IEC
61914:2015. Typical results are detailed below, please note that these testing values are maximums and safety
factors appropriate to your application should be used:
CLASSIFICATION UNITS /
PROPERTY TEST DATA
CLAUSE IEC 61914 CLASSIFICATION
ALUMINIUM IS
CORROSION RESISTANCE 6.5.2.2 HIGH
NON-FERROUS
183kA
RESISTANCE TO CLEATS AT 300MM INTERVALS (REPORT No. PDL-18.071.1)
ELECTROMECHANICAL FORCE 6.4, 6.4.4, 9.5 (WITHSTANDING ONE SHORT
(SHORT CIRCUIT TESTING) CIRCUIT) CABLE OD= Ø36mm
PHASE SPACING = 100MM
113kA
RESISTANCE TO CLEATS AT 1M INTERVALS (REPORT No. PDL-15.025.1)
ELECTROMECHANICAL FORCE 6.4, 6.4.5, 9.5 (WITHSTANDING MORE THAN ONE
(SHORT CIRCUIT TESTING) SHORT CIRCUIT) CABLE OD= Ø117mm
PHASE SPACING = 200MM
The test data provided above is for the standard version only, for test data with the liner option please contact Ellis.
This information is subject to change without notice. The information provided has been generated in laboratory conditions, as such results in use may vary.
41
1F CABLE CLAMPS
UK Design Reg. No: 355854
PART MATERIAL CABLE RANGE DIMENSIONS (mm) FIXING PACK WEIGHT (g)
NO. SUFFIX DIA (mm) W H D E HOLES QTY B LSF LUL
1F-10 B/LSF/LUL 10-13 37.8 27.0 41.4 10.2 1 X M10 100 14.6 19.6 23.8
1F-11 B/LSF/LUL 13-16 41.2 30.0 41.4 10.4 1 X M10 100 17.0 23.0 27.7
1F-12 B/LSF/LUL 16-19 44.3 33.0 41.4 10.7 1 X M10 100 19.6 26.4 32.0
1F-13 B/LSF/LUL 19-23 48.2 36.0 41.4 10.9 1 X M10 100 22.4 30.2 36.5
1F-14 B/LSF/LUL 23-27 52.2 40.0 41.4 11.3 1 X M10 100 25.8 34.6 42.0
1F-15 B/LSF/LUL 27-32 57.1 44.0 41.4 11.6 1 X M10 100 29.2 39.0 47.6
1F-16 B/LSF/LUL 32-38 63.1 49.0 41.4 12.1 1 X M10 100 34.2 46.2 55.7
1F-17 B/LSF/LUL 38-46 71.3 58.0 41.4 12.9 1 X M10 50 47.8 64.0 77.9
1F-18 B/LSF/LUL 46-51 77.3 67.0 41.4 13.5 1 X M10 50 54.0 73.2 88.0
1F-19 B/LSF/LUL 51-57 83.2 72.0 41.4 13.9 1 X M10 50 59.0 80.4 96.2
42
TESTING SUMMARY
1F Clamps have been tested in line with the International Standard ‘Cable Cleats for Electrical Installations’ IEC
61914:2015. Typical results are detailed below, please note that these testing values are maximums and safety factors
appropriate to your application should be used:
LATERAL LOAD RATING 6.4.2, 9.3 NEWTONS (N) REFER TO ELLIS REFER TO ELLIS
10.4kA
CLEATS AT 300MM (REPORT No. PDL-
RESISTANCE TO 17.137.2)
ELECTROMECHANICAL INTERVALS NOT SHORT
6.4, 6.4.5, 9.5 (WITHSTANDING MORE (IEC 61914:2015)
FORCE CIRCUIT TESTED
THAN ONE SHORT PHASE SPACING =
(SHORT CIRCUIT TESTING) CIRCUIT)
100mm
CABLE OD= Ø36mm
APPROVALS:
THE LUL VERSION OF THE 1F ONE HOLE CABLE CLAMPS
ARE COMPLIANT WITH THE REQUIREMENT OF LONDON
UNDERGROUND STANDARD 1-085. PRODUCT REGISTER NO. 363.
This information is subject to change without notice. The information provided has been generated in laboratory conditions, as such results in use may vary.
43
2F+ CABLE CLAMPS
UK Design Reg. No: 355854
PART MATERIAL CABLE RANGE LINER RANGE TAKE DIMENSIONS (mm) FIXING PACK WEIGHT (g)
NO. SUFFIX DIA (mm) THICKNESS WITH LINER W H D E HOLES QTY B LSF LUL
2F+07 B/LSF/LUL 38-46 3 32-40 92 60 54 68 2 X M10 25 73.0 91.0 119.0
2F+08 B/LSF/LUL 46-51 3 40-45 103 71 54 79 2 X M10 25 80.9 109.9 132.0
2F+09 B/LSF/LUL 51-57 3 45-51 103 76 54 79 2 X M10 25 95.0 119.0 155.0
2F+10 B/LSF/LUL 57-64 3 51-58 103 82 54 79 2 X M10 25 89.1 122.5 156.5
2F+11 B/LSF/LUL 64-70 3 58-64 130 89 54 106 2 X M10 10 116.0 157.3 189.0
2F+1200 B/LSF/LUL 70-76 4 62-68 128 95 75 104 2 X M10 10 160.1 190.0 285.0
2F+1201 B/LSF/LUL 76-83 4 68-75 135 100 75 111 2 X M10 10 174.0 206.5 309.8
2F+1202 B/LSF/LUL 83-90 4 75-82 143 108 75 119 2 X M10 10 188.3 228.6 342.9
2F+131 B/LSF/LUL 90-97 5 80-87 165 115 100 138 2 X M12 5 335.5 423.0 634.5
2F+132 B/LSF/LUL 97-105 5 87-95 171 122 100 144 2 X M12 5 355.1 440.6 660.9
2F+141 B/LSF/LUL 105-112 5 95-102 178 130 100 151 2 X M12 5 382.4 509.9 764.9
2F+142 B/LSF/LUL 112-120 5 102-110 187 138 125 160 2 X M12 5 495.6 622.0 933.0
2F+151 B/LSF/LUL 120-128 5 110-118 196 148 125 168 2 X M12 5 536.8 715.7 1073.5
2F+152 B/LSF/LUL 128-135 5 118-125 203 158 125 176 2 X M12 5 578.9 771.9 1157.9
2F+161 B/LSF/LUL 135-144 5 125-134 222 168 150 190 2 X M16 5 831.3 1108.4 1662.7
2F+162 B/LSF/LUL 144-152 5 134-142 232 179 150 200 2 X M16 5 902.3 1203.1 1804.6
2F+171 B/LSF/LUL 152-160 5 142-150 242 190 150 210 2 X M16 5 976.2 1301.6 1952.4
2F+172 B/LSF/LUL 160-168 5 150-158 252 201 150 220 2 X M16 5 1052.1 1402.9 2104.3
2F+ Clamps have been tested in line with the International Standard ‘Cable Cleats for Electrical Installations’ IEC
61914:2015. Typical results are detailed below, please note that these testing values are maximums and safety
factors appropriate to your application should be used:
CLASSIFICATION UNITS /
PROPERTY TEST DATA
CLAUSE IEC 61914 CLASSIFICATION
LSF: PASS
FLAME PROPAGATION TEST 10.0, 10.1 APPLICATION TIME ≥30s
B: NOT COMPLIANT
REFER TO THE DATA TABLE
AXIAL LOAD RATING 6.4.3, 9.4 NEWTONS (N)
OPPOSITE
REFER TO THE DATA TABLE
LATERAL LOAD RATING 6.4.2, 9.3 NEWTONS (N)
OPPOSITE
80.2kA
2F+07LSF CLEATS AT 600MM (REPORT No. PDL-17.137.3)
RESISTANCE TO
6.4, 6.4.5, 9.5 INTERVALS
ELECTROMECHANICAL FORCE
(WITHSTANDING ONE SHORT
(SHORT CIRCUIT TESTING)
CIRCUIT)
CABLE OD= Ø36mm
PHASE SPACING = 100mm
113kA
2F+142LSF CLEATS AT 1M (REPORT No. PDL-17.137.3)
RESISTANCE TO (BASED ON IEC 61914: 2009)
6.4, 6.4.5, 9.5 INTERVALS
ELECTROMECHANICAL FORCE
(WITHSTANDING MORE THAN ONE
(SHORT CIRCUIT TESTING)
SHORT CIRCUIT) CABLE OD= Ø117mm
PHASE SPACING = 200mm
The test data provided above is for the standard version only, for test data with the liner option please contact Ellis.
LONDON UNDERGROUND
The LUL version of 2F+ Clamps are compliant with the requiremnts of LUL-1085. Product register number 364.
This information is subject to change without notice. The information provided has been generated in laboratory conditions, as such results in use may vary.
45
PHOENIX ®
46
TESTING SUMMARY
Phoenix Cleats have been tested in line with the International Standard ‘Cable Cleats for Electrical Installations’
IEC 61914:2015. Typical results are detailed below, please note that these testing values are maximums and safety
factors appropriate to your application should be used:
CLASSIFICATION UNITS /
PROPERTY TEST DATA
CLAUSE IEC 61914 CLASSIFICATION
HORIZONTAL - 350N
LATERAL LOAD RATING 6.4.2, 9.3 NEWTONS (N)
VERTICAL -350N
31kA
RESISTANCE TO CLEATS AT 300MM (REPORT No.
ELECTROMECHANICAL INTERVALS PDL-17.137.1)
6.4, 6.4.5, 9.5
FORCE (WITHSTANDING MORE THAN ONE
(SHORT CIRCUIT TESTING) SHORT CIRCUIT) CABLE OD= Ø36mm
Phase Spacing = 100mm
APPROVALS:
LONDON UNDERGROUND
Phoenix Cable Clamps are compliant with the requiremnts of LUL-1085. Product register number 1661.
This information is subject to change without notice. The information provided has been generated in laboratory conditions, as such results in use may vary.
47
MATRIX ™
TESTING SUMMARY
CLASSIFICATION UNITS /
PROPERTY TEST DATA
CLAUSE IEC 61914 CLASSIFICATION
CLEAT TYPE 6.1.3 COMPOSITE -
TEMP. FOR PERMAMENT
6.2 °C -40 to +60
APPLICATION
UV RESISTANCE 6.5.1.2 REFER TO ELLIS -
IMPACT RATING 6.3.5 VERY HEAVY PASS
FLAME PROPAGATION TEST 10.0, 10.1 APPLICATION TIME ≥30s PASS
AXIAL LOAD RATING 6.4.3, 9.4 NEWTONS (N) REFER TO ELLIS
LATERAL LOAD RATING 6.4.2, 9.3 NEWTONS (N) REFER TO ELLIS
91.3kA
RESISTANCE TO CLEATS AT 300MM (REPORT No.
ELECTROMECHANICAL FORCE 6.4, 6.4.4, 9.5 INTERVALS PDL-18.071.2)
(WITHSTANDING MORE THAN ONE
(SHORT CIRCUIT TESTING) PHASE SPACING = Ø45mm
SHORT CIRCUIT)
(MC-4x1-037-G)
This information is subject to change without notice. The information provided has been generated in laboratory conditions, as such results in use may vary.
48
BESPOKE
BESPOKE SOLUTIONS AND PRODUCTS
We understand that different markets and varying situations demand
different solutions. And as problem solvers, we thrive on new challenges.
So when our standard product range isn’t quite what you need, we can
still help. Visit our website for more information: www.ellispatents.co.uk.
49
MK2 CABLE HANGER
Mild steel cable hanger
* Load Capacity: Brackets with multiple hook configurations are designed to operate with all hooks carrying their maximum load.
As standard, parts are spin galvanised to BS EN 1461 (55μm), thicker galvanising options are available on request.
Dimensions are provided with a tolerance, refer to detailed drawings for details.
This information is subject to change without notice. The information provided has been generated in laboratory conditions, as such results in use may vary.
50
CONVEX CABLE HANGER
Registered design 6254645
* Load Capacity: Brackets with multiple hook configurations are designed to operate with all hooks carrying their maximum load.
As standard, parts are spin galvanised to BS EN 1461 (55μm), thicker galvanising options are available on request.
51
PEGASUS HANGER ®
Hanger SWL kg
100 60
75 45
50 45
CC 25
* Load Capacity: Brackets with multiple hook configurations are designed to operate with all hooks carrying their maximum load.
Dimensions are provided with a tolerance, refer to detailed drawings for details.
This information is subject to change without notice. The information provided has been generated in laboratory conditions, as such results in use may vary.
52
Dimensions (mm) Fixing Holes Pack Modular Weight SWL
Part No. Ways
A B C1 C2 D E F G H I K Diameter Qty. Weight L kg kg
D
C1
Hanger
E
F I
F I
ØK PART NUMBERS FOR SPECIAL CONFIGURATIONS CAN
ØK 75
Hanger 75 BE WORKED OUT AS FOLLOWS:
E
Hanger
I Example: Part Number for product shown would be:
F
F I PG 50-1/75-1/100-1/CC-1
ØK
100 PG defines the product as Pegasus
A
ØK
Hanger 100
E
A
Hanger
E
G
stabalised material add -UV to part#
H
Hanger
H
C2
53
TRIPLEX CABLE SURROUND
UK (2514384), EUROPEAN (2806198)
and US (9,404,605) Patent
NOTE: ‘CABLE RANGE’ REFERS TO THE OUTSIDE DIAMETER THE INDIVIDUAL CABLES INSIDE THE TRIPLEX BRAID
54
CABLE CLEAT SELECTION DETAIL FOR CLEATS TO BE USED WITH THE TRIPLEX CABLE SURROUND
CABLE OD ADAPTOR
SFT OD (mm) VULCAN+ EMPEROR 2F + CLAMP 2A CLAMP
(mm) TYPE
24 56 SFT26 VRT+03 ES51-59 2F+09 2A-09
25 58 SFT26 VRT+03 ES51-59 2F+10 2A-10
26 59 SFT26 VRT+03 ES51-59 2F+10 2A-10
27 61 SFT26 VRT+04 ES58-66 2F+10 2A-10
28 63 SFT26 VRT+04 ES58-66 2F+10 2A-10
***FOR PART NUMBERS IN RED THE WIDER SFT2F+ NEEDS TO BE USED TO SUIT THE INCREASED DEPTHS OF THE CLAMPS***
This information is subject to change without notice. The information provided has been generated in laboratory conditions, as such results in use may vary.
55
SINGLE BOLT FIXING CLAMP
Polymer clamp on steel bracket
This information is subject to change without notice. The information provided has been generated in laboratory conditions, as such results in use may vary.
56
INDUSTRIAL CABLECLAMP
Manufactured as standard in Black LLDPE (B) or in a London Underground Approved Material (LUL).
Used to fix power cables in indoor and outdoor applications.
The LUL version of this clamp is compliant with the requirement of London Underground Standard 1-085. Product Register No. 365.
57
EARTHING STRIP CLIP
Manufactured as standard in Black Polypropylene (B) or Grey Flame Retardant Polypropylene
(FR) Used to fix PVC coated, bare copper or aluminium strip.
IMPERIAL SIZES
Fixing Holes
Material Strip Size Hold Off Length Pack Weight
Part No. (slotted)
Suffix inches inches inches Qty g
inches
60-04 B or FR 1 x 1⁄8 5⁄16 2 7⁄16 x 5⁄16 100 12
60-05 B or FR 1 1⁄4 x 1⁄8 3 ⁄8 2 5⁄8 7⁄16 x 5⁄16 100 21
60-06 B or FR 1 1⁄4 x 3⁄16 5⁄
16 2 5⁄8 7⁄ x 5⁄
16 16 100 20
60-08 B or FR 1 1⁄2 x 3⁄16 5⁄
16 2 5⁄8 7⁄ x 5⁄
16 16 100 20
60-10 B or FR 1 ⁄2 x ⁄8
1 1 3⁄
8 2 5⁄8 7⁄ x 5⁄
16 16 100 20
60-15 B or FR 2 x 1⁄8 1⁄
4 3 ⁄8
1 7⁄ x 5⁄
16 16 100 24
60-26 B or FR 1 x 1⁄8 3⁄
4 2 ⁄81 7⁄ x 5⁄
16 16 100 16
60-27 B or FR 1 x 3⁄16 5⁄
8 2 1⁄8 7⁄ x 5⁄
16 16 100 16
60-28 B or FR 1 1⁄2 x 3⁄16 5⁄
8 2 7⁄8 7⁄ x 5⁄
16 16 100 25
60-32 B or FR 1 1⁄4 x 1⁄4 5⁄
8 3 7⁄ x 5⁄
16 16 100 25
60-34 B or FR 1 1⁄2 x 1⁄8 3⁄
4 3 7⁄ x 5⁄
16 16 100 25
60-36 B or FR 1 1⁄2 x 1⁄4 5⁄
8 3 7⁄ x 5⁄
16 16 100 24
60-37 B or FR 1 1⁄2 x 3⁄8 3⁄
8 2 7 ⁄8 7⁄ x 5⁄
16 16 100 23
60-38 B or FR 1 3⁄4 x 1⁄8 3⁄
4 3 3⁄8 7⁄ x 5⁄
16 16 100 27
60-39 B or FR 1 3⁄4 x 1⁄4 5⁄
8 3 3⁄8 7⁄ x 5⁄
16 16 100 27
60-40 B or FR 2 x 1⁄8 3⁄
4 3 3⁄8 7⁄ x 5⁄
16 16 100 30
60-42 B or FR 2 x 1⁄4 5⁄
8 3 3⁄8 7⁄ x 5⁄
16 16 100 25
60-44 B or FR 2 x 3⁄8 3⁄
8 3 3 ⁄8 7⁄ x 5⁄
16 16 100 24
METRIC SIZES
Fixing Holes
Material Strip Size Hold Off Length Pack Weight
Part No. (slotted)
Suffix mm mm mm Qty g
mm
70-04 B or FR 20 x 4 17 55 11 x 8 100 15
70-06 B or FR 20 x 6 16 55 11 x 8 100 16
70-07 B or FR 25 x 6 16 55 11 x 8 100 14
70-08 B or FR 50 x 4 18 87 11 x 8 100 28
70-09 B or FR 40 x 6 16 87 11 x 8 100 28
70-10 B or FR 50 x 6 15 87 11 x 8 100 26
70-11 B or FR 40 x 4 18 87 11 x 8 100 28
70-12 B or FR 50 x 10 11 87 11 x 8 100 24
70-14 B or FR 60 x 6 18 97 11 x 8 100 31
70-16 B or FR 80 x 6 19 118 11 x 8 50 41
58
FRAMING CHANNEL ACCESSORIES
BUTTERFLY CLIP
Manufactured as standard in Black Nylon, the
butterfly clip snaps into 41mm wide framing channel.
It will accommodate a cable tie of up to 10mm in
width (not included). Used to allow cables to be
strapped at right angles to the channel.
THERMAL SPACER
Manufactured as standard in Black Polypropylene.
A slotted hole is also provided for running heat
detection cable. Used to ensure separation of the
cable on cable ladder, framing channel and ladder
rungs with reduced return flanges.
59
FRAMING CHANNEL ACCESSORIES
CHANNEL NUTS
Manufactured as standard in Bright Zinc Plated Mild Steel.
INSULATION PLATE
Manufactured as standard in Black Polypropylene or Black Flame Retardant VO Zero
Halogen Phosphorus-Free UV Stabilised Nylon (LSF), this insulation plate can be used to
provide a barrier where galvanic reaction may occur between dissimilar metals, e.g. when
installing stainless steel cleats onto galvanised steel channel.
TRUNKING ADAPTOR
Manufactured as standard in Black Polypropylene (B) or Nylon (LSF), this adaptor can be
used to fit one hole and two hole cable clamps when cables are being installed parallel to
the trunking.
60
SPECIALIST CABLE FIXINGS FOR UTILITIES
SINGLE WAY FIXING CABLE CLEAT TWO WAY SINGLE FIXING CABLE
Manufactured as standard in Black
CLEAT
Polypropylene (B) and Grey Flame Retardant Manufactured as standard in Black
Polypropylene (FR) or Black Acetal (A). Polypropylene (B) and Grey Flame Retardant
A robust cleat used for securing armoured Polypropylene (FR). A robust cleat used for
power cables. securing two armoured power cables on flat
surfaces.
61
SPECIALIST CABLE FIXINGS FOR UTILITIES
Fixing
Part Material Cable Dia. Fixing Pack Weight Part Material Cable Dia. Pack Weight
Holes
No. Suffix mm Holes mm Qty g No. Suffix mm Qty g
mm
3WP04 B 11.7 6.35 200 8.0 90-M095 B or FR 9.5 3.75 500 1.8
3WP06 B 13.2 6.35 200 8.2 90-M120 B or FR 12.0 3.75 500 2.4
3WP10 B 16.5 6.35 200 9.8 90-01 B or FR 12.7 3.75 500 2.2
3WP15 B 19.2 6.35 200 12.5 90-02 B or FR 15.0 3.75 500 2.4
3WP20 B 21.7 6.35 200 13.7 90-03 B or FR 17.5 4.0 500 3.3
3WP2 B 15.0 6.35 200 10.7 90-075 B or FR 19.0 4.0 500 3.6
3WN05 B 24.0 6.35 200 11.9 90-04 B or FR 23.0 4.0 500 3.2
90-04.1 B or FR 24.2 4.0 500 3.1
90-05 B or FR 25.4 4.0 500 4.3
90-06 B or FR 27.5 5.0 500 5.3
TWO WAY CLEAT AND SPACER 90-07 B or FR 31.7 5.0 200 6.8
Manufactured as standard in Black 90-08 B or FR 34.0 5.0 200 6.7
Polypropylene (B) and Grey Flame Retardant 90-09 B or FR 38.1 5.0 100 6.8
Polypropylene (FR). Used for mounting power 90-10 B or FR 42.0 5.0 200 8.7
cables to poles and flat surfaces. A spacer is 90-11 B or FR 42.6 5.0 200 9.5
available to facilitate the stacking of the cleat
90-12 B or FR 44.4 5.0 100 7.4
90-13 B or FR 48.7 5.0 200 10.4
Part Material Cable Dia. Fixing Pack Weight 90-14 B or FR 53.9 5.0 100 14.4
No. Suffix mm Holes mm Qty g 90-143 B or FR 55.0 6.0 100 26.3
90-15 B or FR 60.5 6.0 100 25.8
E272 B or FR 11.1-19.1 10.0 50 pairs 22.7
90-19 B or FR 75.0 7.5 50 40.8
E272S B or FR 11.1-19.1 10.0 50 15.1
90-24++ B 88.9 10.0 25 70.7
E273 B or FR 6.35-12.0 6.63 50 pairs 11.4
90-S B Saddle Clip Spacer* 1.2
E273S B or FR 6.35-12.0 6.63 50 7.2
S = Spacer ++ This item is supplied with a base plate.
* Spacer suitable for use with all saddle clips (except part no 90-24).
Provides additional separation of the cable or pipe from the mounting surface of
approximately 12.5mm.
62
JOINTERS’ TOOLS
3 CORE
Part No. Cores Core Range Size mm2 Pack Qty Weight g
3 & 4 CORE
Part No. Cores Core Range Size mm2 Pack Qty Weight g
4 CORE
Part No. Cores Core Range Size mm2 Pack Qty Weight g
63
JOINTERS’ TOOLS
120-CG1C 23 10 57
120-CS 90 10 183
Nominal Lift
Part No. Length mm Width mm Pack Qty Weight g
mm
110-1NYC 150 25 15 10 41
110-2NYC 225 25 25 10 65
110-3NYC 225 25 38 10 89
110-4NYC 150 13 25 10 32
Part No. Core Core Range Size mm2 Pack Qty Weight g
64
LADDER ADAPTORS
65
NOTES
66
NOTES
67
Ellis Patents Ltd T. +44 (0)1944 758395
High Street, Rillington, Malton F. +44 (0)1944 758808
North Yorkshire YO17 8LA [email protected]