Dustroid
Ambient Dust Monitor
Dustroid is an Online Particulate Monitoring system to measure the
concentration of dust particles in the ambient air. It is capable of monitoring
various particulate size ranging from 1 micron to 100 microns such as
Ultrafine Suspended Particulate Matter (UFPM), Suspended Particulate
Matter (SPM), Respiratory Suspended Particulate Matter (RSPM) and Total
Suspended Particulates (TSP). It works on Active Sampling method to count
particulate matters using a highly accurate laser beam. Dustroid can be
used for dust surveys in areas with dust-laden activities like
construction, mining, quarrying, ports, metallurgical processes,
and many more. The data gathered from Dustroid can assist in
dust suppression automation, for instance, to activate
suppressants at the location once the threshold is breached.
Product Variants
Variant Name Application Parameter
Dustroid Smart Urban Monitoring PM1, PM2.5, PM10, PM100 (TSP), Temperature,
& Research Purposes Humidity
Dustroid Pro Mining, Construction, PM1, PM2.5, PM10, PM100 (TSP), Temperature,
(with heated inlet) Industrial Monitoring Humidity
External Modules Optional Wind speed & direction, Rainfall, Noise
(integrable with all the 2 variants)
Sea Ports Construction Sites
Dust pollution at ports from harbour activities Dustroid systems can be installed at
like ship movement, loading-unloading of construction sites to alert authorities when
goods can be reduced by taking timely dust pollution breaches the threshold limit.
actions by authorities. The solution keeps the dust emission within
permissible limits.
Quarries Mines
Dustroid can measure the dust generation Dustroid installation is crucial at mining
due to quarrying activities and automate sites to monitor the particulate generation
water cannons for dust suppression. The and notify the dust suppression crew. The
solution can help identify the occurrence of solution provides a safer working environ-
acute dust events. ment for the miners.
Product Features
Heated Inlet: Dehumidifies the sample to nullify Weather Resistant: IP66 Grade (certified) enclosure
the effect of humidity for better accuracy. for endurance against harsh weather conditions
(only available in Pro variant)
Retrofit Design: Plug and play design for ease of On-device Calibration: On-site device calibration
implementation capability using on-device calibration software
Compact: Light-weight and compact system that Over-The-Air Update: Automatically upgradeable
can be installed at 12-15 feet (4-5 m) height from a central server without any onsite visit
Ultimate Durability: Made of high-grade Real-Time Data: Continuous real-time-data
engineering-metal and composite polymers for transfer possible through various connectivity
long-lifecycle options
Identity & Configuration: Each equipment carries Network Agnostic: Supports a wide range of
its unique identity with geo-tagging through connectivity options like GSM / GPRS / WiFi / LoRa /
wireless configurable sensor NBIoT/ Ethernet / Modbus
Levels of Calibration
Factory Calibration: The sensors are bump tested at
Oizom factory to check their proper functioning with
respect to each parameter.
Collocation Calibration: The sensors are calibrated
against a reference station before installation to test
their performance in the ambient condition.
General Specifications
Size 360mm (H) x 328mm (W) x 200mm (D)
THP Sensor
Weight 6.5 Kg (instrument weight) Dust Sensor
Outlet
Aluminum Magnesium Alloy, Mild-steel Ethernet
Material
Dust Sensor
(With Powder Coating), FRP
Inlet SIM Holder
Certifications CE & FCC Certified, PTCRB Certified
Relay Output
Communication Module
On/Off Switch Modbus / Flood
Power Wind Speed Rain Sensor
Technical Specification Connectivity Specification
Options
Processor Quad Core ARM Cortex
Wireless GSM Global 2G / 3G / 4G
Memory 2GB RAM / 8GB eMMC ROM LORA 868 MHz / 915 MHz
LTE CAT-M1
Device Interface On-device Software / API
NB-Iot CAT-NB1
Operating Temperature -20 °C to 60 °C Sigfox 868 to 869 MHz, 902 to 928 MHz
Wifi AP Mode and Station Mode
Operating Humidity 0-95% RH
Wired Ethernet Static / DHCP Configuration
Modbus RS485 RTU / TCP
Communication
Relay Output 2 Channel
Data Interval 2-30 minutes (configurable)
Data-push Protocol HTTP post request to host-server
Working Principle
Data-pull HTTP request on device IP
Firmware Updates Over-The-Air Firmware Update
Heated Inlet
(only available in Pro variant)
Standby Connectivity GSM (2G/3G) for remote diagnosis,
FOTA updates, and cloud calibration
Particles
Power
5 Watt (Actual consumption depends Detector
Avg. Power Consumption
upon the number of parameters) Laser
Diode
Flow
Power Input Options External 110-230V AC 50-60Hz,
40Watt Monocrystal Solar Panel
SMPS Specs 24V, 2Amps output
Flow Cell
UL-62368 & CAN/CSA C22.2 Certified
Battery Backup Time 12 Hours (not available in Pro variant)
Battery Specs Lithium iron phosphate (LiFePO4)
battery cell with rated voltage 12.8V
Capacity 6Ah
Apply Calibration Curve Pulse Height Distribution
Parameters
Min. Working Measurement Expected
ID Parameter Range Resolution Drift Flow Rate
Detection Principle Principle Sensor Life
Suspended Particulate
OZPM_1 Matters with size less
than 2.5μ (PM2.5)
Suspended Particulate
OZPM_2 Matters with size less 0-5000 μg/m3 Optical Continuous
than 10μ (PM10) 0.1 μg/m3 1 μg/m3 N.A. Particle Flow Active 1 L /min 5000 hours
Ultra-fine Particulate Counter Monitoring
OZPM_3 Matters with size less
than 1μ (PM1)
Total Suspended
OZPM_4 0-30 mg/m3
Particulates (PM100)
OZTEMP_1 Temperature -40 °C to +125 °C 0.01 °C -40 °C N.A.
Solid State Passive
OZHUM_1 Humidity 100% Rh 0.1 % 0.1 % N.A. Semiconductor Monitoring N.A. 2 years
Sensing
OZPRES_1 Barometric Pressure 300-1100 hPa 0.18 Pa 300 hPa N.A.
External Modules 1 Rain Sensor 2 Wind Sensor 3 Noise Sensor
Tipping Bucket Ultrasonic sensor Capacitance
(optional) In mm / inch 360º, 0-40 m/s Upto 140 dB
Min. Expected
ID Parameter Range Resolution Working Principle
Detection Sensor Life
Wind Speed 0-40 m/s 0.1 m/s 0.1 m/s
OZWSD_1 Ultrasonic
Wind Direction 0-359° 1° 1°
3 years
OZRAIN_1 Rainfall Monitoring N.A. 0.5 mm 0.5 mm Tipping bucket
OZN_1 Ambient Noise Up to 140 dB 1 dB 0.5 dB Capacitive 2 years
Functional Specification
Strategic Location Selection
As per EPA's Air Sensor Guidebook (EPA/600/R-14/159), local emission sources, buildings and other such structures
can affect the Particulate Matter concentration.
Hence, it is necessary to ensure free air flow for the sensor by installing it at sufficient height from the ground level.
Ideally, it should be at least 3 meter above, if possible. Also, any local PM emission sources should be avoided for
precise measurements.
DUSTROID
Installation
Preferred Mounting Pole / Wall (preferably 270° open surrounding)
Installation Height 12-15 feet (4-5 meters)
Direction As per maximum direct sunlight exposure
(if ambient-light monitoring is a preference)
12-15 ft
height
Power Availability Constant AC supply within a 2-meter range From
from the unit or solar panel the Ground
Network Availability Uninterrupted network connection 270°
Open surrounding
Operation
Once the device is powered on, the device intakes air samples at a predefined frequency through the sampling
system. The sensor uses light scattering method and emits a laser beam to diffract through the air sample. The
intensity of the beam scattered from the particles at an angle of 45-90º informs about the particle size distribution
and particle concentration.
Maintenance
Cleaning: Periodic cleaning is important to ensure optimum device performance. Monthly or quarterly
regular maintenance activity has to be carried out depending upon the surrounding. The activity includes
cleaning the dome for the light sensor, air inlet, and outlet mesh & general cleaning of the exterior.
Sensor Replacement: Every sensor has a limited life span. The sensor life depends on the average pollutant
concentration in the area. The sensors need to be replaced once their performance starts to deteriorate and
the system starts giving unstable data.
Spot-Calibration: The frequency of calibration is decided based on atmospheric conditions and individual
sensor drift to ensure data accuracy. Spot calibration can be performed using reference equipment which
can also be a recently calibrated Oizom device.
Diagnosis/Debugging: Power and network availability are the prime check in case of equipment failure. If the
issue is still unresolved after remote diagnosis, on-site troubleshooting can be planned by an engineer.
Accurate Air Quality Monitoring And Advanced Data Analytics
306, Indraprasth Corporate,
Prahladnagar, Ahmedabad - India
[email protected] /
[email protected] Visit us at:
+91 88666 60025 / 39
www.oizom.com
© Oizom Instruments Pvt. Ltd. | PB03-V6.3