LD30CPBR10BPxxIO 3327293
LD30CPBR10BPxxIO 3327293
LD30CPBR10BPxxIO - IO-Link
Photoelectric Laser sensor with BGS, FGS and IO-Link communication
Benefits
• Red laser class 1 assure reliable detection
• Red Laser BGS or FGS Long Range sensor with IO-
Link with an adjustable distance of 20 to 125 mm, either
by Teach-button or via IO-Link.
• Dual Detection mode - Combine Foreground detection
with Diffuse Reflective detection.
• Triangulating sensing principle.
• Application functions: Dual Detection, Pattern
Recognition, Speed & Length, Divider function and
Object & Gap Monitoring.
• Neighbour Immunity, select up to 3 neighboring
sensors.
• Easy customization to specific OEM requests by use of
the build in IO-Link functionalities.
• The output can be operated either as a standard
switching output or in IO-Link mode.
• Fully configurable via output IO-Link v 1.1. Electrical
outputs can be configured as PNP / NPN / Push-Pull /
External input, normally open or normally closed.
Description • Timer functions can be set, such as ON-delay, Off-
delay, and one shot.
• Logging functions: Temperature, detecting counter,
The LD30CPBR10BPxxIO are a part of the latest power cycle and operating hours.
generation of high performance Photoelectric • Detection modes Background suppression (BGS),
Laser sensors designed to solve challenging single point, two point, windows and foreground
detection tasks due to Laser, Background suppression (FGS) mode.
Suppression, Foreground Suppression and Dual • Logic functions: AND, OR, XOR and Gated SR-FF.
• Analogue output: In IO-Link mode the sensor
Detection features. The small light spot makes
will generate 16 bit analogue process data output
detection very precise. representing various selectable process data such as
The sensors are implemented in the compact 10 received signal level.
x 20 x 30 mm ABS housing that are acknoledged
world wide.
•
New implemented functions with weight on
functionality, reliability, Predictive maintenance
make these sensors ideal for Industry 4.0.
•
Applications
packaging machine only reveive objects with the correct size and gaps.
Main functions
• The detection distance is almost independent of the colour of the object to detect.
• The sensor can be operated in IO-Link mode once connected to an IO-Link master or in standard I/O mode.
• Measured sensing distance as process data.
• Neighbour interference protection.
• Sensing distance by teach-button, teach by wire or by IO-link parameter.
• Quality of Run and Quality of Teach result.
• Temperature data for preventive maintenance.
• Front-end check for preventive maintenance.
• Dual Detection
References
LD30CPBT10BP IO
Type selection
Connec-
Housing Light type Code
tion
Cable Plastic housing Red laser class 1 LD30CPBR10BPA2IO
Plug Plastic housing Red laser class 1 LD30CPBR10BPM5IO
Structure
G
A
A 2 4
B B C
C
E E
D D 1 3
F G
Sensing
Detection
1. SSC1
S.P.1 (teach/IO-Link) Selector Logic Time Output Sensor
S.P.2 A
A A-B delay inverter output
Hysteresis (man./auto) SSC1 SO1
Logic One of B AND, OR, ON, OFF N.O., N.C. NPN, PNP,
Single point 1 to 7 XOR, S-R One-shot Push-Pull
Sensor front
Two point
Windows
FGS
2. SSC2
S.P.1 Selector Logic Time Output Sensor
S.P.2 B A-B delay inverter output
Hysteresis SSC2 SO2
Logic One of A AND, OR, ON, OFF N.O., N.C. NPN, PNP,
Single point 1 to 7 XOR, S-R One-shot Push-Pull EXT-
Two point B EXT-Input Input
Windows
FGS
3. Temperature
4. Dust 1 7. Application functions
5. Dust 2
Pattern Speed & Divider Object & Gap Dual
6. EXT-Input or or or or
Recognition Length function Monitoring Detection
• 20 ... 125
Set Point 1 (SP1)
Factory settings: 100 (Approx. 100 mm @ Reference target 90% reflection)
• 20 ... 125
Set Point 2 (SP2)
Factory settings: 20 (Approx. 20 mm @ Reference target 90% reflection)
• High active
Switching logic • Low active
Factory settings: High active
SSC1 SSC2
• Deactivated • Deactivated
• Single point mode • Single point mode
Switching mode • Two point mode • Two point mode
• Windows mode • Windows mode
• FGS mode • FGS mode
Factory settings: Single point mode Factory settings: Deactivated
Reference target, white paper with 90
Rated operating distance (Sn) ≤ 100 mm
% reflectivity, Size 200x200 mm
≤ 100 mm White object 90% reflection
Maximum detection distance
≤ 100 mm Grey object 18% reflection
Precise mode
≤ 100 mm Black object 6% reflection
20...150 mm
Factory settings: 150 mm
Cutoff distance Measured distance beyond cut off distance, will be truncated to cut off
distance.
Cut off distance value will also be used when an object cannot be detected.
• IO-Link Adjustment (SSC1)
Sensitivity control ( selectable be-
• Teach-button (SSC1)
tween)
Factory settings: Teach-button
Sensitivity adjustment 20 mm ... 125 mm Teach-button
≤ 15 mm White object 90% reflection
Blind zone ≤ 17.5 mm Grey object 18% reflection
≤ 20 mm Black object 6% reflection
Light source / Light type 650 nm / Red laser modulated, class 1
Typical lifetime Laser > 50 000 h
Detection angle ± 0.4° Fast mode, ± 0.5° Precise mode @ 50 mm
Light spot size Ø 1.0 mm @ 300 mm (1/e2)
Emitter beam angle ± 0.01°
20 ... 125 mm
Factory settings: SP1 100 and SP2 White object 90% reflection
20
20 ... 125 mm
Adjustable distance Factory settings: SP1 100 and SP2 Grey object 18% reflection
20
20 ... 125 mm
Factory settings: SP1 100 and SP2 Black object 6% reflection
20
Adjustable by IO-Link
• Manual 1.0 mm ... 125.0 mm
Hysteresis (H) • Robust automatic
• Fine automatic
Factory settings: Fine automatic
This function can increase the immunity towards unstable targets and
electromagnetic disturbances: Value can be set from 1 to 255.
Detection filter
Factory settings: 1
(1 is max. operating frequency and 255 is min. operating frequency)
• MIP Off
• One channel
• 2 channels - CH A
Mutual Inteference Protection • 2 channels - CH B Factory settings: MIP Off
• 3 channels - CH A
• 3 channels - CH B
• 3 channels - CH C
Application functions
• No application
• Dual Detection
• Pattern Recognition
Selectable dedicated applications Factory settings: No application
• Speed and Length
• Divider function
• Object and Gap Monitoring
Dual Detection
A standard Foreground Suppression sensor expects to see a background within a certain specified tolerance.
An object is detected if the received light’s position exceeds those tolerances set for the background.
A standard Diffuse Reflective (energized) sensor detects the intensity of the received light and if it exceeds a
set threshold an object is detected.
A Dual Detection sensor works as a Foreground Suppression sensor combined with a Diffuse Reflective
sensor. This sensing principle evaluates both the position change as well as the light intensity of the received
light.
• Teach distance
• Teach excess gain
Dual Detection • Set Point
• Hysteresis
• Auto level
Pattern Recognition
The Pattern recognition function detects a pattern (e.g. a row of holes or
Function description
pins) and compares the order with a pre-teached reference pattern.
Conditions Two sensors (Main sensor and Trigger sensor) are needed for this function.
• The Trigger sensor has to detect the full length of the body that contains
the pattern.
Settings
• The Main sensor has to be aimed at the e.g. holes or pins that constitute
the pattern.
Divider function
This function can be used to e.g. monitor how many items are packed into a
Function description carton box. Once the preset number is reached the sensor gives an output
so the full box can be replaced.
Conditions Only one sensor is needed for this function.
A counter value must be set in the sensor.
Settings 1...60 000
Counter limit.
Factory settings: 5
This function is designed to monitor, that the length of an object and the gap
Function description
between the following object on a conveyer belt, are within certain limits.
Conditions Only one sensor is needed for this function.
An acceptable minimum and maximum time [ms] must be set for both the
object size and a gap size between two objects represented by the time it
takes to pass the sensor.
10...60 000 ms
Object minimum time.
Factory settings: 500 ms
Settings 10...60 000 ms
Object maximum time.
Factory settings: 10 000 ms
10...60 000 ms
Gap minimum time.
Factory settings: 500 ms
10...60 000 ms
Gap maximum time.
Factory settings: 10 000 ms
Output 1 is active when an object is outside the set limits.
Outputs
Output 2 is active when the gap between two objects is outside the set limits.
Alarm settings
SSC1 SSC2
Safe limits • 0 ... 100 % of actual SP • 0 ... 100 % of actual SP
Factory settings: 1% Factory settings: 1%
Dust alarm Safe limits are used for dust alarm level.
• High threshold -50 ... +150 °C
• Low threshold -50 ... +150 °C
Temperature alarm Factory settings:
High value 60 °C
Low value -20 °C
Detection diagram
D D
0 0.8 1.6 2.4 3.2 3.9 4.7 0 0.8 1.6 2.4 3.2 3.9 4.7
1.0 0.04 1.0 0.04
B B
Accuracy
Sensing conditions
C C
0 0.8 1.6 2.4 3.2 3.9 4.7 0 0.8 1.6 2.4 3.2 3.9 4.7
20% 20%
18%
15% 16%
14%
10% 12%
A A 10%
5% 8%
6%
0% 4%
2%
-5% 0%
0 20 40 60 80 100 120 0 20 40 60 80 100 120
B B
Fig. 6 Fast mode Fig. 7 Precise mode
A Distance from background (%) (Black on white 6%/90%)
B Distance on white background 90% (mm) (Grey on white 18%/90%)
C Distance on white background 90% (inches] (White on white 90%/90%)
Features
Power Supply
Input selector
Channel A Channel B
• Deactivated • Deactivated
• SSC1 • SSC1
• SSC2 • SSC2
• Dust alarm 1 • Dust alarm 1
Input selector
• Dust alarm 2 • Dust alarm 2
• Temperature alarm • Temperature alarm
• External input • External input
• Application functions • Application functions
Factory settings: SSC1 Factory settings: SSC1
Logic functions
Time delays
Outputs
For SO1 Pin 4 Black wire For SO2 Pin 2 White wire
• Disabled output • Disabled output
• NPN • NPN
• PNP • PNP
Sensor output • Push-Pull • Push-Pull
• External input, active high
• External input, active low
• External teach (Teach-in)
Factory settings: PNP Factory settings: PNP
For SO1 Pin 4 Black wire For SO2 Pin 2 White wire
• N.O. • N.O.
Output Inverter
• N.C. • N.C.
Factory settings: N.O. Factory settings: N.C.
≤ 100mA (continuous) pr. output
Rated operational current (Ie)
100 mA @ 100 nF Load (Short-time) pr. output
OFF-state current (Ir) ≤ 50 μA
Minimum operational current (Im) > 0,5 mA
Voltage drop (Ud) ≤ 1.0 VDC @ 100 mA
Protection Short circuit, reverse polarity, transients
Control of resistive loads and solid-
DC-12
Utilization category state loads with optical isolation
DC-13 Control of electromagnets
Capacitive load 100 nF @ 100 mA, 24 VDC
Operation diagram
Tv = Power-ON delay
Power supply ON
Target (Object) Present
Break output Tv
ON
(N.C.)
Make output Tv
ON
(N.O.)
Response times
Fast mode
Precise mode
Indication
LED indication
Environmental
1)
Do not bend the cable in temperatures below -10°C
2)
With no icing or condensation
EMC
± 8 kV @ air discharge or
Electrostatic discharge immunity test IEC 61000-4-2; EN60947-1
± 4 kV @ contact discharge
Electromagnetic field immunity 10 V/m IEC 61000-4-3; EN60947-1
Fast transient immunity ±2 kV / 5 kHz IEC 61000-4-4; EN60947-1
Wire-conducted noise 10 Vrms IEC 61000-4-6; EN60947-1
Power frequency magnetic field im- Continuous: >30 A/m, 28 µ tesla
IEC 61000-4-8; EN60947-1
munity test Short-time: >300 A/m, 280 µ tesla
Diagnostic parameters
Events Configuration
Observation menu
Mechanics/electronics
Connection
Wiring
1 BN V
4 BK
A
2 WH
B
3 BU
V
BN BK WH BU A B
Brown Black White Blue OUT/IO-Link IN/OUT
Housing
Body ABS
Front glass PMMA, Red
Teach-button FKM, Fluoroelastomer
Indication TPU, Transparent
Dimensions 10.8 x 30 x 20 mm
≤ 50 g Cable version
Weight
≤ 20 g Plug version
Dimensions
17
1.5
1.1
10.6
3.5
20
5.5 5.5
25.4
30
15
10.6
10.8
Fig. 8 Cable
17
1.5
1.1
10.6
3.5
20
5.5 5.5
25.4
30
15
10.6
10.8
10.25
Fig. 9 Plug
Compatibility and conformity
CE-marking
Approvals (UL508)
FDA accession number: 2220061-000
Class 1 laser according to IEC
60825-1:2014
Complies with IEC / EN 60825-
Other Approvals 1:2014 and 21 CFR 1040.10
1040.11 except for deviations
pursuant to Laser Notice No. 56,
dated January 19, 2018
IO-Link
Delivery contents and accessories
Delivery contents
Accessories
Further information
Connectors http://cga.pub/?0aae3e
COPYRIGHT ©2023
Content subject to change. Download the PDF: www.gavazziautomation.com
Authorized Distributor
Carlo Gavazzi:
LD30CPBR10BPA2IO LD30CPBR10BPM5IO