The document provides safety instructions for installing an irreversible operator for sliding gates. It covers important safety instructions, checking before installation including ensuring the gate moves frictionless, electrical connections, and keeping the instructions for future reference.

Uploaded by

StefanIonita
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
119 views8 pages

1543098-Moveo 600kg 230v

The document provides safety instructions for installing an irreversible operator for sliding gates. It covers important safety instructions, checking before installation including ensuring the gate moves frictionless, electrical connections, and keeping the instructions for future reference.

Uploaded by

StefanIonita
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

MOVEO

OPERATORE IRREVERSIBILE PER


CANCELLI SCORREVOLI

IRREVERSIBLE OPERATOR FOR


SLIDING GATES

OPERATEUR IRREVERSIBLE POUR


PORTAILS COULISSANTES

OPERADOR IRREVERSIBLE PARA


VERJAS CORREDERAS

SELBSTHEMMENDER
TORANTRIEB FÜR SCHIEBETOREN

6-1624870 /R.1

Operatore Alimentazione Centralina Codice


Operateur Power Supply Control unit Code
Operator Alimentation Centrale de commande Code
Operador Alimentacion Cuadro de mando Codigo
Torantrieb Stromspannung Steuereinheit Code

MOVEO 800 230V 50/60Hz BIOS1 12007922

MOVEO 600 230V 50/60Hz BIOS1 12007920

MOVEO 600 120V 50/60Hz BIOS1 120 12007930

MOVEO 700 24V 24Vdc BIOS1 24 12007950


IMPORTANT SAFETY INSTRUCTIONS FOR THE INSTALLATION CHECKING BEFORE THE INSTALLATION
- ATTENTION - FOR THE SAFETY OF THE PEOPLE IT IS IMPORTANT !! THE GATE SHALL MOVE FRICTIONLESS !!
TO FOLLOW ALL THE INSTRUCTIONS. Note: Gate features must be uniformed with the standards and laws in
force. The door/gate can be automated only if it is in a good condition and
1° - This handbook is exclusively addressed to the specialized personnel
its conditions comply with the EN 12604 norm.
who knows the constructive criteria and the protection devices
- The door/gate leaf does not have to have a pedestrian opening. In the
against the accidents for motorized gates, doors and main doors
opposite case it is necessary to take the appropriate steps, in accordance
(follow the standards and the laws in force).
with EN 12453 norm (for instance; by preventing the operation of the
2° - The installer will have to issue to the final user a handbook in
motor when the pedestrian opening is opened, by installing a safety
accordance with the EN 12635.
microswitch connected with the control panel).
3° - Before proceeding with the installation, the installer must forecast
- Besides the electrical or mechanical limit switches available on the
the risks analysis of the final automatized closing and the safety of
operators, there must be, on both ends of the installation, a fixed
the identified dangerous points (following the standards EN 12453/
mechanical stopper which stop the gate in the unlikely event of ill
EN 12445).
functioning of limit swithces on the operators. For this reason the fixed
4° - The wiring harness of the different electric components external to
mechanical stopper must be of an adeguate size to withstand the static
the operator (for example photoelectric cells, flashlights etc.) must be
and kinetic forces generated by the gate.
carried out according to the EN 60204-1 and the modifications to it
The guide must be provided with two mechanical stops at its ends.
ENG

done in the point 5.2.2 of the EN 12453.


- Gate columns shall have anti-derailment guides on their top, to avoid the
5° - The possible assembly of a keyboard for the manual control of the
unintentional gate release.
movement must be done by positioning the keyboard so that the
person operating it does not find himself in a dangerous position;
Parts to install meeting the EN 12453 standard
moreover, the risk of accidental activation of the buttons must be
USE OF THE CLOSING
reduced.
6° - Keep the automatism controls (push-button panel, remote control COMMAND TYPE Skilled persons
Skilled persons
(out of public Unrestricted use
etc.) out of the children way. The controls must be placed at a area*)
(public area)
minimum height of 1,5m from the ground and outside the range of with manned
the mobile parts. A B non possibile
operation
7° - Before carrying out any installation, regulation or maintenance with visible impulses
operation of the system, take off the voltage by operating on the C or E C or E C and D, or E
(e.g. sensor)
special magnetothermic switch connected upstream it. with not visible
impulses
C or E C and D, or E C and D, or E
THE ALLMATIC COMPANY DOES NOT ACCEPT ANY RESPONSIBILITY for (e.g. remote control
device)
possible damages caused by the non observance during the installation of
the safety standards and of the laws in force at present. automatic C and D, or E C and D, or E C and D, or E
* a typical example are those shutters which do not have access to any public way
KEEP THESE INSTRUCTIONS WITH CARE A: C ommand button with manned operation (that is, operating as long as activated).
B: Key selector with manned operation.
1° - Install a thermal magnetic switch (omnipolar, with a minimum C: Adjustable power of the motor.
contact opening of 3 mm) before the control board, in case this D: Safety strips and/or other safety devices to keep thrust force within the limits of
is not provided with it. The switch shall be guaranteed by a mark EN12453 regulation - Appendix A.
of compliance with international standards. Such a device must E: Photocells.
be protected against accidental closing (e.g. Installing it inside the
control panel key locked container).
2° - As far as the cable section and the cable kind are concerned, ELECTRICAL CONNECTIONS
To correctly connect the gearmotor to the control unit, follow the table below:
ALLMATIC suggests to use an H05RN-F cable, with a minimum
section of 1,5mm2, and to follow, In any case, the IEC 364 standard DESCRIPTION COLOUR
and Installation regulations In force In your Country. PHASE 1 Black
3° - Positioning of an eventual pair of photocells: The beam of the
PHASE 2 Brown
photocells must be at an height not above the 70 cm from the
ground, and, should not be more than 20 cm away from the axis of COMMON Grey or light blue
operation of the gate (Sliding track for sliding gate or door, and the GROUND Yellow / Green
hinges for the swing gate). In accordance with the point 7.2.1 of EN
12445 their correct functioning must be checked once the whole GROUND CONNECTION
installation has been completed. The system must be grounded.
4° - In order to comply with the limits defined by the EN 12453 norm, if Use the predisposed clamp, connected to the yellow / green cable, to
the peak force is higher than the limit of 400N set by the norm, it is connect the gearmotor to the ground system.
necessary to use an active obstacle detection system on the whole
height of the gate (up to a maximum of 2,5m) - The photocells in MAINTENANCE
this case must be apply externally between the colums and internally To be carried out exclusively by skilled persons after the power supply to
for all the race of the mobil part every 60÷70cm for all the height of the motor has been interrupted.
the column of the gate up to a maximum of 2,5m (EN 12445 point Periodically, when the gate is standstill, clean and keep the guide free from
7.3.2.1). example: column height 2,2m => 6 copies of photocells - stones and dirt.
3 internal and 3 external (better if complete of syncronism feature).
N.B.: The system must be grounded
Data described by this manual are only Indicative and ALLMATIC reserves
to modify them at any time. Install the system complying with current
standards and regulations.
8 / 32 6-1624870 rev.1 09/05/2019
SYSTEM LAYOUT

J J

K K

ENG
L Fig. 1
A- MOVEO operator
B- Photocells (external)
C- Rack M4
D- Key selector
E- Tuned antenna
F- Flashing lamp
G- Limit switch cams
H- Safety edge fixed to column
I - Safety edge with wireless system
J- Photocells (internal)
K- Galvanized column for photocells
L- Mechanical stops

VERSIONS AND TECHNICAL FEATURES

Irreversible operating devices for sliding gates. The irreversibility of this operating device allows you to avoid using any electric lock for an effective closing
of the gate. The motor is protected by an heat probe, that temporary interrupts the operating cycle in case of prolonged use.

TECHNICAL FEATURES MOVEO 600KG 230V MOVEO 800KG 230V MOVEO 600KG 120V MOVEO 700KG 24V
Code 12007920 12007922 12007930 12007950
Code (magnetic limit switch) 12007925 12007926 12007935 12007951
Max. leaf weight Kg 600 800 600 700
Operating speed m/s 0,20 0,20 0,23 0,22
Thrust force to constant turns N 500 600 500 600
Rack M4 M4 M4 M4
Power supply 230V~ 50Hz 230V~ 50Hz 120V~ 60Hz 230V~ 50Hz
Motor power supply 230V~ 50Hz 230V~ 50Hz 120V~ 60Hz 24Vdc
Nominal power W 270 290 410 75
Current absorbed A 1.3 1.4 3.5 3
Capacitor µF 12.5 12.5 50 -
Daily operations suggested n° 200 200 200 400
Guaranteed consecutive cycles n° 10 10 10 50
Service % 30 30 30 100
Noise db <70 <70 <70 <70
Working temperature °C -10...+55
Protection IP 44

6-1624870 rev.1 09/05/2019 9 / 32


BASE PLATE INSTALLATION
1. Push the achors until they are 90° as shown in the picture
2. Insert the 4 screws (supplied) as shown in the image, from the bottom to the top of the backing plate
3. Screw completely the 4 nuts (supplied) as shown in the image
4. Position the backing plate with the tightened screws and nuts on the concrete foundation (wet cement)
5. Wait for the necessary time (2-3 weeks)
6. Unscrew the nuts previously tightened from the 4 screws
7. Proceed with the positioning and fixing of the MOVEO geoarmotor (use the same nuts previously used)

Plan for one or more sheathing for the passage of the power lines.
Note: It is necessary to know the rack dimensions to can calculate exactly the counter-plate positioning (Fig. 4).
ENG

Fig. 2

Fig. 3 Fig. 4
h1 93 mm
h2 2 mm (backing plate thikness)
d1 0 ÷ 10 mm

10 / 32 6-1624870 rev.1 09/05/2019


MOTOR FITTING

254

ENG
100
42

Fig. 5

To fix the motor to the counterplate, insert and screw the 4 nuts (Fig. 5). Position the motor in parallel with the gate and with the gear under the rack
as shown in Fig. 8.
N.B. It is important to energetically tighten the 4 nuts, making sure that the gearmotor is firmly on the ground during the entire stroke of the gate.

RACK FITTING
The rack must be fixed at a certain height with respect to the motor fixing plate (Fig. 3). This height can be changed thanks to the slots on the rack.
The height adjustment is made so that the gate doesn’t rest on the motor gear drive (Fig. 7) during movement. To fix the rack on the gate, make
holes of Ø 5 mm and thread them using a male of the M6 type. The drive gear must be approximately 1 mm to 2 mm away from the rack
(Fig. 7).

1mm...2mm

Fig. 7
GEARMOTOR POSITIONING IN RELATION TO THE GATE

WARNING! Position the motor with the pinion under the rack as
NO OK shown in figure 8
WARNING ! The distance between the motor and the gate must be
constant throughout the stroke.

Fig.8

6-1624870 rev.1 09/05/2019 11 / 32


LIMIT SWITCH FITTING
In order to determine the gate travel length, place two cams (Fig. 9) at the ends of the rack (Fig. 10). Move the cams on the rack teeth to adjust their
opening and closing travel. To fix the cams to the rack, tighten the screws issued.
Note: In addition to the electric stop cams mentioned above, you must also install strong mechanical stops preventing the gate from sliding out from the
top guides.

SX DX

Fig. 9 Fig. 10
ENG

INSTALLATION AND REGULATION OF MAGNETIC HALL LIMIT SWITCHES. Only for versions with magnetic limit switches
Rack 28 x 20 / 6410001 (nylon with steel core) Rack 30 x 12 / 6410005 (galvanized steel)

40 mm MAX
40 mm MAX

Fig. 11 Fig. 12

B 12
A

NOTE: If necessary make 2 additional holes to improve the fixing (A) and copy If you use the steel rack type 30 x 12 (CODE 64100005) use the supplied
them on the rack. Pay attention to the screws choice, they mustn’t be too long spacers and position them as shown in the figure to respect the distance
and obstruct the grip. indicated.

Magnetic limit swithces connection


+ 24Vdc White
- GND Brown
COM Yellow
L.S.1 Green
L.S.2 Grey

WARNING! There must be a maximum distance of 40 mm between the magnet attached to the rack and the sensor on the
body of the motor. (Fig. 11, Fig. 12)

12 / 32 6-1624870 rev.1 09/05/2019


GATE POSITIONING IN RELATION TO HORIZONTAL PLANE

Fig. 13 Fig. 13

OK NO
For special installations request information from Allmatic or use larger geared motors.

RELEASE
To move the gate manually it is necessary to release the gearmotor inserting the key, turning it for 90° and open the lever (Fig. 14).

ENG
In order to carry out the manual operation of the gate leaf the followings must be checked:
- That the gate is endowed with appropriate handles;
- That these appropriate handles are placed so to avoid safety risks for the gearmotor;
- That the physical effort necessary to move the gate leaf should not be higher than 225 N, for doors/gates for private dwellings, and, 390N for doors/
gates for commercial and industrial sites ( values indicated in 5.3.5 of the EN 12453 norm).

Fig. 14

DISPOSAL OF THE PRODUCT


This product is an integral part of the automation, and therefore, they must be disposed of together. As for the installation operations, at the end of the life
of this product, the dismantling operations must be performed by qualified personnel. This product is made from different types of materials: some can be
recycled, others must be disposed of. Please inform yourselves on the recycling or disposal systems provided for by the laws in force in your area, for this
category of product.
CAUTION! – some parts of the product can contain polluting or dangerous substances which, if dispersed in the environment, may cause serious
harm to the environment and human health.
As indicated by the symbol at the side, it is forbidden to throw this product into domestic refuse. Therefore, follow the “separated collection” instructions
for disposal, according to the methods provided for by local regulations in force, or redeliver the product to the retailer at the moment of purchase of
a new, equivalent product.
CAUTION! – the regulations in force at local level may envisage heavy sanctions in case of abusive disposal of this product.

WARRANTY
In compliance with legislation, the manufacturer’s guarantee is valid from the date stamped on the product and is restricted to the repair or free
replacement of the parts accepted by the manufacturer as being defective due to poor quality materials or manufacturing defects. The guarantee does
not cover damage or defects caused by external agents, faulty maintenance, overloading, natural wear and tear, choice of incorrect product, assembly
errors, or any other cause not imputable to the manufacturer. Products that have been misused will not be guaranteed or repaired. Printed specifications
are only indicative. The manufacturer does not accept any responsibility for range reductions or malfunctions caused by environmental interference. The
manufacturer’s responsibility for damage caused to persons resulting from accidents of any nature caused by our defective products, are only those
responsibilities that come under Italian law.

6-1624870 rev.1 09/05/2019 13 / 32


ALLMATIC S.r.l
32020 Borgo Valbelluna - Belluno – Italy
Via dell’Artigiano, n°1 – Z.A.
Tel. 0437 751175 – 751163 r.a.
www.allmatic.com - E-mail: [email protected] 6-1624870