Vdocuments - MX - Open Drain Separator Sizing
Vdocuments - MX - Open Drain Separator Sizing
17-Jul-2013
Home Software for creation of pipe classes and Software for the design and mechanical calculation
About mechanical calculation of piping components. of pressure vessels and heat exchangers. Read
News Read more ... more ...
Products
Tools
Library Learn more about training on Plant Engineering and Design:
Forum e-learning by International Institute of Plant Engineering
Contact and Design
Applicable design rules for a specific project shall be spe cified in the Design Basis a nd / or the General Info rmation and
Instructions (GII) for the project.
Library section
For both types of separators the design rules will be given in this design guide.
The configuration of a vapor/liquid separator depends on a number of factors. Before making a vessel design one has to decide
on the configuration of the vessel with respect to among others:
Orientation
Type of heads
Gadgets powered by
Advanced Piping Desig n is an Factors that help to make the choice between the various alternatives are discussed in this chapter. Google
intermediate-level handbook
covering guidelines and 3.1 Orientation of the Vessel
procedures on process plants
and interconnecting piping The selection of the orientation of a gas-liquid separator depends on several factors. Both vertical and horizontal vessels have
systems. their advantages. Depending on the application one has to decide on the best choice between the alternatives.
liquid removal efficiency does not vary with liquid level because the area in the vessel available for the vapor flow remains
constant
the downward liquid velocity is lower, resulting in improved de-gassing and foam breakdown;
additional to vapor / liquid separation also a liquid / liquid separation can be achieved (e.g. by installing a boot).
The preferred orientation for a number of typical vapor / liquid separation applications are:
The feed nozzle size and the type of feed inlet device (if any) have an impact on the vapor / liquid separation that can be
achieved. The feed nozzle is normally sized to limit the momentum of the feed. The limitation depends on whether or not a feed
inlet device is installed.
Various inlet devices are available to improve the vapor / liquid separation. Among others the following inlet devices may be
installed:
a deflector baffle
a half-open pipe
a 90 ° elbow
a schoepentoeter
For vertical drums, preferably a deflector baffle or a half open pipe shall be selected. In case of a slug flow regime in the inlet
piping, or if a high liquid separation efficiency is required, a tangential inlet nozzle with annular ring can be used. However, in case
a high liquid removal efficiency is required, the application of a wire mesh demister is preferred.
For horizontal drums normally a 90° elbow or a slotted diverter is installed. In some cases a submerged inlet pipe is installed, but
this shall not be done in the case of a two-phase feed.
Normally the selected inlet device for a horizontal drum shall be:
a submerged pipe when the feed is a subcooled liquid and the mixing of liquid and blanket gas is to be minimized
3.3 Internals
After passing throug h the feed inlet, the vapor stream will still contain liquid in the form of droplets. T he maximum size of th ese
entrained droplets depends on the vapor upflow velocity. A separation device can reduce this entrainment significantly. Wire mesh
demisters are the most commonly used as separation device. They are used for two reasons:
To minimize entrainment
Of the drum services having such a requirement, suction drums for reciprocating compressors are the most notable examples
The allowable vapor velocity in a drum can be increased significantly by using a wire mesh demister. So, when sizing is governed
by vapor-liquid separation criteria, this will result in a smaller diameter of the vessel
Although the size o f the vessel often can be reduced by applyin g a wire mesh demister, there are also many services where there
is normally no demister installed. Reflux accumulators, for example, seldom have mist eliminators.
There are several other types of mist eliminators such as vanes, cyclones, and fiber beds. They are used when conditions are not
favorable for wire mesh screens. Selection criteria for these types of internals are the required efficiency, capacity, turndown ratio,
maximum allowable pressure drop and fouling resistance. These types however will not be further addressed in this design guide.
Most vessels have 2:1 elliptical heads, welded to the shell of the vessel. However, in some cases other types of heads are used.
The major alternatives are:
Flat heads
In case of small vertical vessels (diameter less than approximately 30”) often a flanged top head is used, which also serves to
provide access to the vessel. Depending on the pressure rating, this type of head can either be flat or elliptical, and shall be
selected in consultation with the mechanical engineer
Hemispherical heads
A dished head sho uld be considered in the case of a large diame ter, low-pressure vessel
In the sizing of vessels the proper definition of hold-up time and liquid levels is important. For the design of vessels the following
shall be used:
Liquid hold-up time Working volume between High Liquid Level (HLL) and Low Liquid Level (LLL)
The design of a vapor-liquid separator is based on the terminal settling velocity of a liquid droplet of specified size, settling under
the influence of gravity. This velocity is given by:
(4.1)
where
The vapor handling capacity (K ) depends on the type of service of the vessel. Typical values are:
t
Application K
t
The separator shall be large enough to handle the gas flow rate under the most severe process conditions. For systems, which
have a foaming tendency, such as glycol and amine solutions, a derating factor of 0.7-0.8 shall be used for K . A derating factor of
t
0.7-0.8 shall also be used for compressor suction knockout drums.
The level instrument determines the LLL. For mechanical reasons, the nozzle of this instrument should be at least 150
mm above the bottom tangent line. The level instrument requires an additional 50 mm. Therefore, the LLL is about 200
mm above the bottom TL of a vessel. In case of doubt the instrument engineer shall be consulted on the minimum
required LLL.
2. The height required for the liquid hold-up
The liquid hold-up is defined as the volume between the High Liquid Level (HLL) and the Low Liquid Level (LLL). This
volume consists of the standard hold-up plus additional volume in case of slug or trip-alarm levels. Typical hold-up times
are:
1) As a minimum a Fuel Gas KO drum shall be sized to contain a slug of liquid equivalent to the content of 6 mtr inlet
piping.
If slugs of liquid can be expected, additional volume shall be provided to ensure that the required vapor / liquid separation
can still be achieved.
3. The clearance between the High Liquid Level and the inlet nozzle
The clearance between the HLL and the inlet nozzle shall be 0.3 times the vessel diameter, with a minimum of 0.3 m.
4. The diameter of the inlet nozzle
The diameter of the inlet device depends on the inlet flow and on the type of inlet device. See section 4.5.1 for the sizing
criteria of the inlet nozzle.
5. The clearance between the inlet device and the top TL
The required clearance between the inlet nozzle and the top TL depends on the presence of a demister.
Without a demister, the clearance shall be 0.7 times the vessel diameter with a minimum of 0.9 m.
With a demister, the clearance shall be:
0.45 times the vessel diameter, with a minimum of 0.9 m to the demister, plus, 0.1 m for the demister, plus
0.15 times the vessel diameter, with a minimum of 0.15 m for the clearance between the demister and the top TL
The sizing is for a vertical vessel with and without a demister is summarized in figure 4.1.
The calculation of the diameter and the length of a horizontal vessel can not be separated. The cross-sectional area of the vapor
space is based on a maximum allowable vapor velocity given by equation 4.1. The sizing of a horizontal vapor / liquid separator is
based on a trial-and –error method. The sizing method consists of the following steps:
1. Calculate the required liquid volume (V ) based on the selected liquid holdup time. The liquid volume is given by:
liq
(4.2)
1. As a first estimate, assum e that the liquid volum e is 60 % of the total volume. Select an L/D ratio and calculate the ve ssel
diameter. The vessel diameter is given by:
(4.3)
where:
L/D the ratio between the length and the diameter (-).
If there are no other factors, which determine the L/D ratio of a vessel, the design pressure is normally used to select this
ratio. Recommended L/D ratio’s are:
2. Select the Low Liquid Level (LLL). Typically the LLL is set at 0.2 m, but it shall be checked with the mechanical engineer
whether this is feasible. Calculate the cross-sectional area below the LLL , using the following set of equations:
(4.4)
3. Calculate the total cross-sectional area required for the liquid by adding to the cross-sectional area below the LLL the
area required for the liquid hold up. The total liquid cross-sectional area is given by:
(4.5)
4. Calculate the HLL, using similar formula’s as in step 4, or the special function in Excel. Determine the remaining vapor
cross-sectional area.
5. Calculate maximum allowable vapor velocity using
(4.6)
Based on the vapor space above the HLL, the actual vapor space must be calculated and compared against the
maximum allowable vapor velocity. In case of a large required vapor area, two vapor inlet nozzles shall be considered,
thereby reducing the required vapor space by 50%.
A. Limitations on HL L
The HLL shall not be higher than 80% of the diameter, with a minimum height of the vapor space of 0.3 m. If a demister is
installed, the minimum height of the vapor space is 0.6 m
The vapor space must be sufficiently high to accommodate the feed inlet device. At least 150 mm shall be available between the
bottom of the inlet device and the HLL
Either a 90°elbow, or a half-open pipe can be used as inlet device for a horizontal vessel. A 90°elbow is preferred, as they are
easier to fabricate. The following requirements are applicable for 90°elbow inlets:
The diameter of the elbow must be the same as the nozzle diameter.
An impingement b affle should be installed op posite to the elbow to protect the drum shell. Th e baffle diameter shou ld be
twice the inlet nozzle diameter. A thickness of ¼“ for the baffle plate is recommended.
The minimum distance between the elbow and the HLL is 150 mm (6”).
The elbow should be installed as close as possible to the tangent line considering reinforcement and fabrication
requirements (150 mm).
Short radius elbows shall be used, with 3“ straight pipe inside the drum.
4.3.3 Boot
When there is a chance that the liquid contains some water or other immiscible fluid a boot can be provided to collect the heavier
fluid phase. A boot will only be selected if the following criteria are satisfied:
In all other cases overflow/underflow weirs shall be used for proper liquid/liquid separation.
The sizing of the boot diameter shall satisfy the following criteria:
The boot diameter shall not be more than 0.5 times the vessel diameter
The minimum boot diameter depends on the diameter of the vessel, and shall be as listed below:
900<D<1400 400
D>1400 500
The heavy liquid draw-off velocity shall not exceed 80% of the rising velocity of the light liquid. Because of the small size of the
droplets, in most cases the Stokes law can be applied to calculate the rising velocity of the droplets.This results in:
Moreover, the design settling velocity should be limited to 10 inch per minute even if a higher rate is calculated.
The light liquid phase outlet shall extend 100 to 150 mm above the bottom of the vessel, and be equipped with a vortex
breaker
The light liquid phase outlet shall be located downstream of the boot and as close as possible to the tangent line of the
vessel
The boot shall be located on the opposite side form the inlet, as close as possible to the tangent line. The distance is not
determined by process reasons, but by the saddle support. Therefore, contact with the mechanical department is
required
4.4.1 Degassing
When good degassing of liquid is required, the dimensioning of the vessel shall also satisfy criteria for the separation of gas
bubbles out of the liquid phase. Because of the small size of the bubbles, in most liquids the Stokes law can be applied to
calculate the rising velocity of the bubbles. This results in:
For vertical vessels it shall be ensured that the downward liquid velocity in the vessel doesn't exceed the calculated rising velocity
of the bubbles.
For horizontal vessels it shall be ensured that the residence time below the low liquid level will allow the selected minimum size
bubble to travel the distance between the vessel bottom and the low liquid level.
4.4.2 Foaming
In case the liquid handled has a tendency to foam, the design shall take this into consideration. Although there is no solid basis to
do so, the following can be used as a guide:
For horizontal vessels, add the height of the foam above the high liquid level, to allow for the reduced vapor space for
vapor/liquid disengagement. (typically 0.3 mtr or 1 ft)
For vertical vessels, Company limits the downwards liquid velocity to:
(4.10)
The internal nozzle diameter may be taken equal to that of the feed pipe, but also the following momentum criteria shall be
satisfied:
Other momentum criteria are applicable for high vacuum units or other units where the inlet velocity can be very high because of
the low gas density.
The diameter of the gas outlet nozzle should normally be equal to that of the outlet pipe, but also the following criterion shall be
satisfied:
In High Vacuum Units this criterion may result in a high outlet velocity, leading to a pressure drop which is too high. In that case,
the gas outlet nozzle shall be sized such that the pressure drop requirements between column and downstream system are met.
The diameter of the liquid outlet nozzle shall be chosen in relation to the outlet line size selected, and is often based on a liquid
velocity of 1 m/s. As liquid circulating above the liquid outlet nozzle may result in vortex formation, the design shall include
measures to avoid this. This can be done in two ways:
Allow adequate liquid h eight above the outle t nozzle. For checking the required minimum liquid height above the o utlet
nozzle see graphs in Appendix I.
Install a vortex breaker
Normally vortex breakers are provided on outlet nozzles that serve as outlet to a pump.
4.5.4 Manway
The size of a manway is usually 24”, unless internal devices require larger size for installation. If the vessel diameter is 30” or
less, a flanged head may be considered in stead of a manway. For mechanical reasons manways should be smaller than one-half
of the vessel inside diameter.
As an alternative to a manway, smaller vessels can be provided with an inspection hole, wh ich is normally 8”.
As defined in the E ngineering Guide for the Preparation of Enginee ring Flow Diagrams (BN-EG-UE208), para. 5 .2.4 the size of
vents and drains on vessels shall be:
Up to 17 m3 2” 2”
17 to 200 m3 3” 3”
200 to 400 m3 3” 4”
400 to 700 m3 4” 6”
Additional to vents an d drains vessels may be provided with steam out and utility connections. No rmally these connections a re 2”.
If not specifically defined for the project, the nozzles on a vessel shall be identified as follows:
Instrument nozzles K1, K2, K3 etc., where multiple nozzles for a single instrument shall
be identified K1A\B\C etc
Utility connections UC
In case a high liquid separation efficiency is required, a mist eliminator can be installed to ensure the removal of smaller liquid
droplets. Also a mist eliminator can be installed to reduce the size of a vertical vapor / liquid separator. Normally a demister pad is
installed as mist eliminator.
Important: In case a vessel is provided with a demister pad, the relief valve protecting the vessel shall be mounted upstream of
the demister pad to reduce the change of blockage in the relief valve inlet and to reduce pressure drop.
The demister pad is sized based on a maximum allowable vapor velocity through the pad, given by vendor rules. A typical sizing
rule for demister pads is given by equation 4.13 however for separators operating under vacuum conditions vendor information
shall be consulted.
For vertical vessels the details on demister installation and vessel sizing are given in para. 4.2.
For horizontal vessels the following applies for the use of demister pads.Horizontally installed demister pads:
The minimum clearance between the top of the vessel and the demister pad is the larger of 12” or half the length of the
longer side of the pad.
The design of the vessel remains the same as for a horizontal vessel without mist eliminator. except for the minimum
length, which is not specified from inlet to outlet nozzle but from inlet to demister pad.
In case the separation efficiency of the vessel should be very high, two vertical and one horizontal demister can be
installed in the vapor phase. The vessel requires an inlet nozzle at each end, terminated by an elbow or a half-open pipe,
and one vapor outlet nozzle at the center of the vessel. This setup reduces the required cross-sectional vapor area by
50%. However, with small low-pressure vessels, the savings from the smaller diameter may be offset by the cost of the
vertical demisters and the extra inlet.
The distance between the inlet device and the front face of the demister mat shall be at least 0.6 m or 0.5 times the
vessel diameter
The distance between the downstream side of the outlet nozzle and the rear face of the demister mat shall be at least
0.5D.
Normally, liquid / liquid separation is achieved in a horizontal vessel, providing adequate residence time to properly separate the
required droplet size from both the liquid phases. The most commonly used types are:
Completely filled vessels with liquid draw-off via nozzles at the top and bottom of the vessel
Vessels also providing vapor space, with overflow and underflow baffles, which are separating the liquid / liquid
separation compartment from compartments for liquid draw-off
The former type of separator is used when there is no chance of vapor formation, while the latter is used when there is a chance
of vapor formation.
Rules for the design of coalescor type liquid / liquid separators, where the separation is enhanced by internals (e.g. plate packs,
wire mesh), are not given in this design guide. Design rules for this type of separator shall be based on vendor information.
The sizing of a liquid filled liquid / liquid separator is based on the required residence time for:
separating small droplets of light fluid from the heavy phase fluid
separating small droplets of heavy fluid from the light phase fluid
Based on the type of application, one of the two above mentioned criteria may be skipped.
The sizing of this type of liquid / liquid separator is based on trial and error and requires the following steps:
Initial vessel dimensions can be selected based on an overall liquid residence time, e.g. 15 minutes. Initial high and low interface
levels can be selected to get a hold-uptime for the larger of the two phases of approximately 3 minutes (for control purposes), and
about identical hold-up times for both phases, with the interface at the normal level.
Because of the small size of the droplets, in most cases the Stokes law can be applied to calculate the settling velocity of the
droplets. This results in:
(5.1)
The required residence time must be calculated for both phases, to allow the selected droplet size to travel between the interface
and the top or bottom of the vessel. These residence times must be compared with the actual residence time of both phases at
the interface. Because of the shape of the vessel, it is required to check the required residence time of both phases against the
actual at various interface levels, e.g. at the low and high interface level.
Based on the outcome of the calculations a new set of (high and low) interface levels can be selected, or a new size vessel.
A liquid / liquid separat or with a vapor compartme nt is well known, and ofte n used as the accumu lator of an ejector base d vacuum
system. The sizing of these horizontal vessels includes the sizing based on vapor / liquid separation as described before and the
sizing of the liquid / liquid separation. In this section only the sizing for liquid / liquid separation is discussed. In case there is only
a very small amount of vapor flowing through the vessel, the High Liquid Level shall be taken at max. 80% of the diameter of the
vessel.
The liquid / liquid separators with a vapor compartment have three liquid compartments, one for the liquid / liquid separation and
one each for the hold-up of the separated light and heavy phase. These compartments are separated by overflow and underflow
baffles, which ensure a proper hold up time of the two phases in the separating compartment.
Also the sizing of this typ e of liquid / liquid separat or is based on trial and e rror and requires the following st eps:
Initial vessel dimensions can be selected based on an overall liquid residence time, e.g. 15 minutes with a HLL at 80% of the
vessel diameter.
2. Select the heavy phase overflow baffle height and calculate the resulting interface
By selecting the height of the heavy phase overflow baffle the liquid / liquid interface can be calculated based on a pressure
balance, using the following equation:
H xρ H x ρ + (H -H ) x ρ
1 h= h h 2 h l
Where:
The overflow baffles must be positioned to get adequate hold up in the overflow compartments for proper control of the outgoing
fluid. Normally a hold up of approximately three minutes between a HLL and LLL is adequate.The distance between heavy phase
underflow and overflow normally is 200 mm, however this shall be checked to minimize pressure drop.
To check the liquid / liquid separation the droplet settling velocity for both phases must be calculated. Because of the small size of
the droplets, in most cases the Stokes law can be applied to calculate the settling velocity of the droplets. This results in:
(5.2)
where
Based on the calculated interface level and settling velocities the required residence time for the light and heavy fluid must be
calculated and compared with the actual residence times.
Based on the outcome of the calculations some of the assumed values have to be adjusted. In case there are only minor
differences between the actual and required residence times, adjustment of the overflow and underflow baffles (in height and / or
location) will be sufficient, in the case of larger differences, the overall size of the vessel will have to be adjusted.
Because of the fixed overflow baffles, the interface level will change with changes in fluid densities. As this affects the separation,
the design shall be checked for possible changes in these densities. For the same reason it is recommended to have the top of
the heavy fluid overflow baffle adjustable (e.g. +/- 100 mm)
As a final check on t he dimensions, the va por / liquid separation mu st be checked based on the vapor residence time and the
settling velocity of the light fluid droplets to be removed from the vapor.
6. Computer Programs
Various computer applications have been developed for the sizing of vapor \ liquid separators. These are:
6.1 Depsep
This program has been developed to size vapor \ liquid separators based on the "Company" rules. A typical output is given in
Appendix IV.
6.2 Separator
This program, originally a Lotus 123 spreadsheet, has been developed to size vapor \ liquid separators based on "Company"
rules.
In Excel a number of special functions have been developed to calculate vessel characteristics. Among other the following
functions have been developed:
Calculates the volume of liquid in a horizontal vessel based on vessel diameter, vessel length, liquid level and type of head.
Vessel Diameter
Vessel Length
Liquid Volume
Type of Head
(For a quick estimate refer to the 'Tools' section of the Red-Bag website.)
Vessel Diameter
Vessel Length
Liquid Level
Type of Head
Vessel Diameter
Vessel Length
Liquid Volume
Type of Head
Calculates the cross sectional area of a horizontal vessel below a given level based on:
Vessel diameter
Level height
7. Appendices
I Graphs
II I Typ ica l Da ta Sh ee t
IV DEPSEP Output
V SEPARATOR Output
B211
Benzeen Destillaat Vat
DEPSEP OUTPUT
SEPARATOR OUTPUT