0% found this document useful (0 votes)
197 views24 pages

Daikin's Indian Market AC Solutions

Daikin customizes a new line-up of packaged air conditioning products for the Indian market produced in their manufacturing facility in Neemrana, Rajasthan. The line-up includes high static pressure duct type units up to 20 HP as well as rooftop units and horizontal water source heat pumps. The products offer features like operation at high ambient temperatures of 48°C, under and over voltage protection, phase imbalance protection, and phase reversal protection.

Uploaded by

miyaintaj400
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
197 views24 pages

Daikin's Indian Market AC Solutions

Daikin customizes a new line-up of packaged air conditioning products for the Indian market produced in their manufacturing facility in Neemrana, Rajasthan. The line-up includes high static pressure duct type units up to 20 HP as well as rooftop units and horizontal water source heat pumps. The products offer features like operation at high ambient temperatures of 48°C, under and over voltage protection, phase imbalance protection, and phase reversal protection.

Uploaded by

miyaintaj400
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 24

WORLD’S LEADING AIR CONDITIONING

COMPANY FROM JAPAN

Packaged AC
Catalogue
Versatility is the mark
of Perfection

HIGH STATIC ROOFTOP WATER SOURCE


SERIES SERIES HEAT PUMP SERIES
Table
of Contents
01 Product Line-up 14 Horizontal Water
Source Heat Pump

04 Air-Cooled (Ductable) 17

11 Air-Cooled (Rooftop)

Daikin customizes packaged line-up of


airconditioning products for Indian market.

Daikin believes in being close to its as phase imbalance voltage & Phase
customers. As a result we have reversal protection. We have also
developed a new range of packaged introduced aesthetically appealing new
products tailor-made for Indian wired LCD remote controller, with glossy
conditions. This new line-up of products finish, for ease of usage of our packaged
produced in Daikin India’s manufacturing air-conditioner. The new line-up of
facility at Neemrana, Rajasthan ensures packaged air conditioners gives you
reduced lead time and greater array of cutting-edge technology in air
features for Indian consumers. conditioners with industry-leading energy
Advanced features include cooling at efficiency for lower power bills. These
high-ambient temperature, Under locally produced high-static pressure duct
voltage & over voltage protection as well type are available up to 20 HP (16.7 TR).
01

Product Line-up
HIGH STATIC PRESSURE DUCT TYPE (Cooling only)
CAPACITY

Btu/h 66,000 1,02,000 1,32,000 1,29,600 1,98,000

TR 5.5 8.5 11 10.8 16.5

INDOOR
UNIT

FDR65FRV16 FDR100FRV16 FDR130FRV16 FDR130FRV162 FDR200FRY16

OUTDOOR
UNIT

RR65FRY16 RR100FRY16 RR130FRY16 RR65FRY16(Nos.2) RR100FRY16(Nos.2)

HIGH STATIC PRESSURE DUCT TYPE (Cooling only)


CAPACITY

Btu/h 66,000 1,02,000 1,32,000 2,00,000

TR 5.5 8.5 11 16.7

INDOOR
UNIT

FD65DSV16 FD100DSV16 FD130DSV16 FD200DSY16

OUTDOOR
UNIT

R65DSY16 R100DSY16 R130DSY16 R100DSY16 (Nos. 2)

HIGH STATIC PRESSURE DUCT TYPE (Cooling Only)


CAPACITY

Btu/h 2,50,000 3,50,000 5,00,000

TR 20.8 29.2 41.7

INDOOR
UNIT

FD250B2Y1M FD350B3Y1M FD500B4Y1M

OUTDOOR
UNIT

R130DSY16x2 Nos R100DSY16x1 Nos / R130DSY16x2 Nos R130DSY16x4 Nos


02

Product Line-up
AIR-COOLED ROOFTOP UNITS (Cooling only)
CAPACITY

Btu/h 62,500 93,400 1,24,500 1,54,400 1,89,000 2,48,600

TR 5.0 8.0 10.0 13 16.0 21.0

ROOFTOP
SERIESUATQ-C
UATQ60CGXY1 UATQ90CGXY1 UATQ120CGXY1 UATQ150CGXY1 UATQ180CGXY1 UATQ240CGXY1

AIR-COOLED ROOFTOP UNITS (Heat Pump)


CAPACITY

Btu/h 93,300 1,21,400 1,52,600 1,90,000 2,28,000 2,47,700

TR 7.8 10.1 12.7 15.8 19.0 20.6

ROOFTOP
SERIESUATYQ-C
UATYQ250MCY19 UATYQ350MCY1 UATYQ450MCY1 UATYQ550MCY1 UATYQ600MCY1 UATYQ700MCY1
03

HORIZONTAL WATER SOURCE HEAT PUMP


Btu/h (Cooling) 9380 17907 22682 29913 34791 42636
CAPACITY

Btu/h (Heating) 11153 20806 24217 30868 34961 44341


TR (Cooling) 0.78 1.49 1.89 2.49 2.90 3.55
TR (Heating) 0.93 1.73 2.02 2.57 2.91 3.70

UNIT

MWH010DRP MWH020DRP MWH025DRP MWH030DRP MWH040DRP MWH050DRP

Btu/h (Cooling) 54574 64806 83736 100620 113922 127907


CAPACITY

Btu/h (Heating) 56757 67398 87086 104645 118479 133023


TR (Cooling) 4.55 5.40 6.98 8.39 9.49 10.66
TR (Heating) 4.73 5.62 7.26 8.72 9.87 11.09

UNIT

MWH060DRP MWH070DRP MWH080DRP MWH100DRP MWH125DRP MWH150DRP

Daikin’s Packaged
Air-conditioners are
engineered to meet high
static and large airflow
for wider coverage
requirements.
04

Air-Cooled (Ductable)
AIR CONDITIONERS
FDR-FRV/FRY Series
High static pressure duct type** FD-DSV/DSY Series

FDR65FRV16 FDR100FRV16

FDR130FRV162* FDR200FRY16

Improved Features

New wired
LCD remote controller
New LCD based wired type remote handset
with alphabetic error display like HP, LP, SPPR,
indoor fan current sensor etc. In-built energy
saver dedicated button and glossy finish.

High performance even at


high ambient temperature
Always keeping your comfort in mind,
Daikin ducted air conditioners work at
480C high ambient temperature (48°C) without
tripping. Get the best out of Daikin
ducted air conditioners even in
hot weather conditions.

Note: *Available in twin circuit also. **Models available in R-22 also (5.5 ~16.7 TR).
05

Best in class
Air Conditioning Components
Best in Class high grade Components of
Daikin Ducted Air Conditioners ensures
high energy efficiency, High Cooling,
high comfort and high reliability.

Under voltage and


over voltage protection
Given the erratic electricity supply
it becomes important that your air
conditioners are guarded against
under voltage and over voltage.
Daikin ducted air conditioners offer
protection against voltage fluctuation
thus enhancing the operating life of
your air conditioners.

Phase imbalance voltage


It is vital that your air conditioner is
protected against imbalance and Daikin
duct air conditioners offer this protection
to ensure reliable operation of the air
conditioner. Electrical equipment especially
motors and their controllers will not operate
reliably on unbalanced voltages. Greater
imbalances may cause overheating of
components and damage the air conditioners.
06

Phase Loss Protection


In case of any phase loss Daikin machine
will display error on its controller.

Phase reverse protection


Phase reversal could cause serious
problems therefore much care is required
to protect the motor from such type of
fault. Daikin duct air conditioners offer
protection from phase reversal thus
enhancing the life of the air conditioners.

Pre-charged refrigerant
Daikin India’s FDR65, FDR100,
FDR130 and FDR200 models are
available with pre-charged refrigerant
for 7.5 meter piping length. No need
for additional refrigerant charge on-site
if piping length is upto 7.5 meters.
07

Comfortable
Superior air distribution
for comfortable living
The conditioned air can be effectively distributed to every corner
of the room through the ducting and this ensures a pleasant
environment for comfortable living.
L-shaped U-shaped Long

Air discharge orientation


FDR65-200 models come with standard horizontal air discharge. Horizontal blow
room room room Return air

Flexibility of air supply


Air flow can be adjusted by using Fan speed button on LCD Remote controller.

Versatility
Multiple rooms can be cooled together at the same time by using just one unit of fan coil unit.

Fresh air intake for healthy living


Fresh air can be introduced into the building through the design of fresh air intakes. This will help to improve the indoor air quality.

Compact

Compact design of
built-in type helps blend
with interior decor
Indoor models are compact in size
and designed with twin coil structure.
This design effectively saves space
during installation.

Compact size
To fit in tight ceiling spaces, 450 mm
few models are available with
450 mm height only
08
Work & Servicing

Easy maintenance
The simple design concept has provided the ease
of maintenance and servicing. Access to the internal
part of the unit can be from the service panel or
other side of the unit by loosening a few screws.

Remote Controller

NEW
Wireless & Wired
Remote Controllers Wired Remote Model Number
4P408280-1(FDR/FD 65/100/130),
4P416386-1(FDR/FD200)
Wireless Remote Model Number
BRC4N151

Others

Air Filter as standard


Washable Air Filter is equipped as standard.

Outdoor Unit

Scroll compressor
All outdoor units are using scroll compressor which has better energy efficiency and quiet in operation.

Anti-corrosion of heat exchanger fin


The heat exchanger fin of outdoor units are anti-corrosion treated.

Scroll compressor

Scrolls

High
Efficiency
Motor

Quiet
Shutdown
Device
09

Advantage of High Performance Components FDR-FRV Series (5.5TR~16.5TR)

Compressor
Compressor is known as heart of any Refrigeration & Air
conditioning system.
Daikin uses highly efficient Scroll compressor which ensures better
Volumetric Efficiency, Low noise ,reliable operation, built in safety.

ODU Fan
Aerodynamic design High efficiency Propeller Fan for optimize Airflow distribution
thus better heat transfer& lower noise level best suited for high Ambient conditions.
The Outdoor fan and fins that act as heat syncs draw the heat away so the unit
doesn't overheat.
The outdoor condensing unit becomes very hot with all that overheated refrigerant
running through it. The Outdoor fan and fins that act as heat syncs draw the heat
away so the unit doesn't overheat.

Motor
High RPM motors to improve airflow ,better insulation
Thermal Overload protector used for motor safety.

HP/LP Switch
These switches are design for Highly Precise Setting & Repeatability
HP Switch: The high pressure switch cuts-off power supply in case
of excess compressor discharge pressure thereby preventing
equipment damage.
LP Switch: The low pressure switch monitors the refrigeration
system for loss of refrigerant charge.
It also helps in stopping the evaporator (indoor) coil from freezing due
to a clogged/dirty filter or lower airflow over the coil.
10

Heat Exchanger
Blue Fin Condenser and Hydrophilic special coating on the fin of the
heat exchanger prevents corrosion, extending the life of the unit to
increased enhance performance.
Optimum Area Heat exchanger of both 7mm tubes & 3/8'' Heat
Exchanger increasing heat transfer area which increases cooling
capacity & Performance during high ambient temperature.

TEV
Thermostatic expansion valve(TEV) regulates refrigerant flow to cater to variations in
heat load and make the system more efficient by controlling Superheat & matches
system capacity.
over a broader temperature range. It increases the flow of refrigerant to provide better
cooling at higher temperatures. It’s design Protects the compressor motor by
preventing liquid slugging, which can damage compressors.

Drier
Filter Drier for liquid line protects refrigeration and air-conditioning
system by removing High moisture, acids and solid particles. With
these contaminants eliminated, systems are safer from harmful chemical
reactions. These are shock resistant built in steel shell construction.

Stop Service Valve


Function: Stop valve is used to connect indoor and outdoor units.
Good Quality of stop Valve ensures high Reliability.

Metallic PCB Box


Metallic PCB Box ensures safety from Fire
11

Air-Cooled (Rooftop)
AIR CONDITIONERS - The Comfort with Higher Efficiency.

Rooftop

UATQ60/90/120/150/300 UATYQ250/350/450/550/ With optional economiser kit*


180/240CGXY1 (Cooling Only) 600/700MCY1 (Heat Pump)

Package Unit
Daikin’s new range of rooftop packaged units has been

are designed to be easy to install, requiring only ducting

compact design gives an aesthetic and neat appearance


when installed in line of sight. The unit cabinet is made of
powder coated sheet metal especially suitable for outdoor
use. All parts of the structure are fastened with corrosion
resistant screws and bolts.

High Operating Range


Designed for high ambient application. Continuous
operation at an outdoor ambient temperature up to 52°C.

Flexible Air Supply utilising Variable Pitch


Pulley
Utilising the Variable Pitch Pulley (VPP) driven supply
fan, VPP can be adjusted on site to meet a wide range of

pulley and belt.


12
Convertible Return and Supply Air* Standard Handset
Unit can be easily converted from horizontal to vertical User friendly wired remote controller for
UATQ-C series with following functions:
relocating the panels and supply air fan mounting.
7 days programmable timer (on/off)
Compressor running display
Scroll Compressor Real time clock
Key lock function
compressors. Each compressor is mounted on rubber Energy saving mode
vibration isolators in order to reduce the noise level and Error code display
vibration transmissions.

Powder Coated Condensate Drain Pan


The sheet metal condensate drain pan is powder coated to
resist corrosion.

Rooftop Panel for UATYQ - MCY1 series comprises


Slots for 2 Inch Return Air Filters all starting, operating and safety controls setting.
A 2 inch rail is provided as standard in instances where a
7 days programmable timer with 3 set of ON/
OFF, timer/day
Dirty indication
Rating Alarm & Warning diagnostic
The UATQ-C series is designed to achieve high energy Password protection for advanced setting
savings. Its performance is claimed to be among
the best in the market.

*Selected models (Refer data book)

Component Features
1 Condenser Fan and Motor
Fans are of propeller type, direct driven by
weatherproof electrical induction motors. Condenser
fan motor has class F insulation and splash-proof
enclosure of up to IP55*.
• UATQ60/90/120/150/180/210/240/300CGXY1:
IP55
• UATYQ600/700MCY1: IP55
• UATYQ250/350/450/550MCY1: IP44

2 Condenser
Condenser coils are manufactured from seamless
inner grooved copper tubes mechanically bonded
3 Casing / Structure
All coils are tested against by Nitrogen holding
The unit casing used in UATQ-C & UATYQ-MCY1
at 609psig and highly precise Helium leak test at
series is made of zinc coated galvanized steel
235psig. All standard coils are up to 3 rows/14-16
sheets. It is further coated with an electrostatic
FPI, 3/8” (9.52mm) O.D. tubes.
powder coat and then oven-baked for a tough and
UltraGold Fin is offered as standard (1000hrs Salt
Spray Tested), which has longer life span under are used throughout to further reduce possibility
corrosive environment. of unit rusting.
13

4 Evaporator
V-belt drive as standard. It has class B insulation
Evaporator coils are manufactured from
and dripping water proof, IP22.
seamless inner grooved copper tubes
7 Expansion Device
optimum heat transfer. All coils are tested against
Electronic Expansion Valve is used to ensure
by Nitrogen holding at 609psig and highly
precise Helium leak test at 235psig. All standard
coils are 3-4 rows/14-16 FPI, 3/8” (9.52mm) 8 Compressor
O.D. tubes.
Compressor used in UATQ-C & UATYQ-MCY1
UltraGold Fin is offered as standard (1000hrs Salt Series Packaged Units are hermetically sealed
Spray Tested), which has longer life span under scroll type. All the compressors are provided with
corrosive environment. an internal overload protection.

5 Insulation 9 Refrigerant Circuit


All possible areas of condensation are insulated Each refrigerant circuit have independent
by PE, Polythelene. Panel insulation is 10mm electronic expansion devices, HP/LP switch and
thick while drain pan insulation is 5mm thick. refrigerant line service pressure ports as standard
factory HP/LP switch and refrigerant line service
6 Evaporator Fan and Drive pressure ports as standard factory installed.
Blower is DWDI centrifugal, forward curved type.
It is mechanically and dynamically balanced and
mounted on a rigid shaft in a self aligned bearing

Economiser* Optional Features


Economiser is available as an option to cater for horizontal 3rd Party Thermostat*
or vertical air discharge/return.
For application that requires uniform thermostat outlook
with other electrical appliances. 3rd Party thermostat
can be connected to the factory supplied module via the
contact point available on the PCB board.

Basic BMS Connection


Unit’s standard PCB board provides dry contact for basic
Supply Air BMS connection. Input signal will go to dry contact ON/
OFF, COOL/HEAT and 4 to 20 mA temperature adjuster
Return Air Fresh Air while output signal will come from ON/OFF, COOL/HEAT,
ALARM and DEFROST dry contact.
Horizontal Discharge / Return
CO2 Sensor*
2
sensor can be easily plugged on the
control board’s dry contact, which is available on the
economiser extension board.

Auxiliary Heater*
Auxiliary heater connection point is available on the

Fresh Air
Return Air

Vertical Discharge / Return


*Combination possible only with R-410A Heat Pump rooftop unit
14

Horizontal Water
Source Heat Pump

MWH-D

Energy saving and Reproducible Energy Sources


environmental protection The MWH-D series take use of ground water, surface
water, ground and other resource which include low-quality
Pioneer of Environmental Protection energy which is renewable energy sources.
Water source heat pump MWH-D series use environmental
refrigerant R410A. R410A is higher volumetric capacity, The unit can be applied to water loop system, water source
system, ground water system or other water system due to
the ozone layer. wide-range working condition.

Refrigerant ODP Temperature slip Volumetric Efficiency


capacity
R410A 0 0.5 141 100
R407C 0 4.4 95 98
R22 0.05 0 100 100

Notes: ODP is a relative value of R11

At present, McQuay measures ACOP instead of COP Water Sourse System Water Loop System

Ground Loop System

for the whole year. The highest ACOP is 4.94, for


MWH060DRP, which is higher beyond national standard
(GB) 4.55.
Flexible application
ACOP = 0.56*EER + 0.44*COP
EER = cooling capacity/cooling input power, Flexibility in Static Pressure Selection
COP = heating capacity/heating input power. McQuay MWH-D series (1HP-7HP) take use of high-
performance fan motor. For 8HP-15HP units ,
4 types of ESP option is provided to meet
air supply requirement.

This test room is Nationally Recognized Testing Laboratory 1HP~7HP


15
Easy Maintenance No Refrigerant Liquid Attack
MWH-D series are designed with assess doors and knobs MWH-D series are designed with liquid accumulator which
in three directions, which is easier for service engineers to can store redundant refrigerant when operation condition
change parts on site. changes so that to prevent compressor from liquid attack.

Assess Door

Assess Door Assess Door

Scroll Liquid Accumulator

Convenient Installation Superior IAQ


MWH-D series have charged refrigerant R410A before
shipment. Customers only need to wiring, install water
pipes and air ducts on job site. So installation cost air continously.
is highly reduced.

Air Out

Assess Sheet Filter


Connect Hose
Valve
Water Inlet
Water Switch
Water Outlet Condensate water pipe
Intelligent Control System
Intelligent Control System
With full accessories
MWH-D series adapt various ways of control, including
Standard MWH-D series come along with accessories
standard wired controller(MC322) and other options, for
including: wired controller, 8m communication cable,
example: wireless remote card controller, central controller
(max to 64 units), Smart Commander and supporting BMS
make installtion more convenient and easier.
system under Modbus.
Passivating Sheet

Anti-corrosion Wired Wireless Centralized


Controller Card Type Controller
Safety & Reliability
(MC322+8m (Optional) (Optional)
Multiple Protections wiring)
MWH-D series are designed with multiple protections: the (Standard)
high and low pressure protection, water leakage protection
and circulating water temperature protection. The wired
controller is installed with sound, light and code alarm,
which feedback fault information fastly to make McQuay MWH Smart
sure formal operation. Commander Software

Modbus Smart Commander Software


(Optional) (Optional)
Note: For above option, please contact factory in advance
16
Performance Curve
Different Conditions Different Air Flow
Cooling Curve Heating Curve
1.10 Cooling Power Input
Heating Ratio

Heating Ratio

DB Temperature of Air Return °C

Correction Table
18 Heating Capacity
20 Cooling Capacity
22 Heating Power Input

DB Temperature of Air Return °C


25 1.05
27 Sensible Heat Factor
(sensible heating capacity/
cooling capacity)
1.00
Note: The above
legends are suitable for
0.95 the performance Curve
of different air flow.

0.90

0.85
DB Temperature of Air Return °C
DB Temperature of Air Return °C

Sensible Heat Factor


Heating Ratio
0.80
Cooling Ratio

27
0.75
25

22
0.70
20
18
0.65
6 10 14 18 22 26 30 34 35 70% 80% 85% 90% 95% 100% 105% 110% 115%
Water Inlet Temperature °C Water Inlet Temperature °C

Correction Table of Water Temperature Difference


Water Inlet/Outlet 10 9 8 7 6 5 4
Temperature Difference
Water Flow 0.500 0.560 0.620 0.720 0.840 1.000 1.130
Cooling Capacity 0.986 0.990 0.994 0.997 0.999 1.000 1.001
Heating Capacity 0.978 0.984 0.990 0.997 1.001 1.000 0.994
Cooling Power Input 1.043 1.034 1.025 1.016 1.008 1.000 0.989
Heating Power Input 0.989 0.992 0.994 0.996 0.998 1.000 1.004

Operating Range
Operating Range Cooling Heating

Indoor Air DB Temperature 16—35°C 10—30°C


Cooling Capacity 13—40°C 6—35°C

Note: If the units run beyond above operating limit, it may cause damage to the units.
17

Specifications
HIGH STATIC DUCT TYPE (Cooling only)

5.5TR 8.5TR 11.0 TR 10.8 TR 16.5 TR

FDR65FRV FDR100FRV FDR130FRV FDR130FRV FDR200FRY


Indoor Unit
16 16 16 162 16
Model
RR65FRY RR100FRY RR130FRY RR65FRY RR100FRY
Outdoor Unit
16 16 16 16(2Nos) 16(2Nos)

Btu/
66000 102000 132000 129600 198000
Nominal Cooling Capacity Hr

KW 19.3 29.9 38.7 38 58


Actual Capacity % Minimum 90% of Nominal Capacity
Nominal Total Input Power (Cooling) W 6400 11000 14600 13000 21600
Running Current A 11 19 23 22 38

Power Source V/Ph/


415/3/50
Hz
Refrigerant Type --- R-410A
Control Operation --- Wired Control
High cfm 2200 3400 4400 4400 6600
Air Flow Medium cfm 2045 3100 3850 3850 5800
Low cfm 1890 2800 3330 3330 5000
Static Pressure High Pa 50 50 60 60 80
INDOOR UNIT

Sound Pressure Level (H) dBA 51 52 54 54 59

Height x
Unit Dimension Width x mm 450x1170 450x1660 470x1700 470x1700 590x1885
Depth x700 x700 x940 x940 x1145

Height x
Packing Dimension Width x 465x1370 585x1880 620x1930 620x1930 755x2130
mm
Depth x720 x740 x990 x990 x1250

Unit Weight kg 60 95 125 130 175


Condensate Drain Size mm 40.5

Height x
Width x mm 930x1025 930x1200 930x1650 930x1025 930x1200
Unit Dimesion
Depth x410 x550 x620 x410 x550

Height x
Width x 1080x1170 1080x1350 1088x1846 1080x1170 1080x1350
Packing Dimension mm
Depth x470 x620 x720 x470 x620
OUTDOOR

Unit Weight kg 96 147 173 96 147


Type --- Liquid (Flared) & Gas (Brazed)
Pipe
Connection Size Liquid mm 12.7 12.7 15.9 12.7 12.7
Gas mm 22.2 28.6 28.6 22.2 28.6

Refrigerant Pre-Charged
(At 7.5m Pipe Length) kg 4.4 5.7 8 2X4.4 2X5.9*

Note: All specifications are subject to change by the manufacturer without prior notice.
Cooling capacity is based on the conditions below:
Cooling - 27°C DB / 19°C WB indoor and 35°C DB outdoor.
Refrigerant (R-410) is pre-charged at factory shipment (Outdoor Unit).
18

Specifications
HIGH STATIC DUCT TYPE (Cooling only)
5.5 TR 8.5 TR 11.0 TR 16.7 TR 20.8 TR 29.2 TR 41.7 TR
Indoor unit FD65DSV16 FD100DSV16 FD130DSV16 FD200DSY16 FD250B2Y1M FD350B3Y1M FD500B4Y1M
Model R100DSY
R130DSY 16x1 Nos R130DSY
Outdoor unit R65DSY16 R100DSY16 R130DSY16 R100DSY16x2
16x2 Nos R130DSY 16x4 Nos
16x2 Nos
Btu/h 66000 102000 132000 200000 250000 350000 500000
Capacity
kW 19.34 29.9 38.7 58.6 73.27 102.58 146.53
Total Input Power W 6450 9500 13000 19510 25568 36783 51720
Running Current A 11 17 22 33 44.4 62.9 89.7
Power Source V/Ph/Hz 415 / 3 / 50
Refrigerant Type R-22
Control Operation LCD Wired Controller
High cfm 2200 3400 4400 6600 8000 10500 15000
Air Flow
Medium cfm 2045 3100 3850 5800 - - -
Low cfm 1890 2800 3330 5000 - - -
High Pa 50 50 60 80 200 343 250
Sound Pressure Level
INDOOR UNIT

dBA 53 53 57 59 63 66 68
Unit Dimension Height mm 450 450 470 590 1231 1486 1486
Width mm 1170 1560 1700 1885 1766 2022 2174
Depth mm 700 700 940 1145 1069 1069 1336
Packing Dimension Height mm 465 585 620 755 1506 1766 1766
Width mm 1370 1780 1930 2130 2034 2279 2431
Depth mm 720 740 990 1250 1412 1422 1684
Unit Weight kg 60 90 128 175 343 440 606
Condensate Drain Size mm 40.5 25.4 25.4 25.4
Unit Dimension Height mm 930
Width mm 1025 1200 1650 1200 1650 *1200/1650 1650
Depth mm 410 550 620 550 620 *550/620 620
Packing Dimension Height mm 1080 1080 1088 1080 1088 *1080/1088 1088
INDOOR UNIT

Width mm 1170 1350 1846 1350 1846 *1350/1846 1846


Depth mm 470 620 720 620 720 *620/720 720
Unit Weight kg 95 144 160 144 160 *144/160 160
Pipe Connection Type Brazed
Size Liquid mm 12.7 12.7 15.8 12.7 15.8 *12.7/15.8 15.8
Gas mm 22.4 28.58 34.92 28.58 34.92 *28.58/34.92 34.92
Refrigerant Pre-Charged (At 7.5m Pipe Length) kg 4.2 6 8.7 6.0 (x2) 8.7 *6/8.7 8.7

Note:
Cooling capacity is based on the conditions below:
Cooling - 27°C DB / 19°C WB indoor and 35°C DB outdoor.
Refrigerant (R-22) is pre-charged at factory shipment (Outdoor Unit).
*Given value is for 2 Nos ODU as per ODU model details mentioned above.
19

ROOFTOP SERIES (Cooling only)


5.2 TR 7.8 TR 10.4 TR 12.9 TR 15.8 18.3 20.7 26.0
Model
UATQ60C UATQ90C UATQ1 20C UATQ150C UATQ1 80C UATQ240C UATQ240C UATQ300C
Btu 62,500 93,400 1,24,500 1,54,400 1,89,000 2,20,000 2,48,600 3,12,200
Rated Capacity
kW 18.32 27.37 36.49 45.25 55.39 64.48 72.86 91.5
Total Power Input kW 4.52 7.20 9.45 12.00 14.72 16.90 19.29 24.52
Total Running Current A 8.20 13.50 17.00 24.10 27.20 33.90 38.70 46.00
COP W/W 4.05 3.80 3.86 3.77 3.76 3.82 3.78 3.73
Power Source V/Ph/Hz 380-415V/3/50 380-415V/3/50 380-415V/3/50 380-415V/3/50 380-415V/3/50 380-415V/3/50 380-415V/3/50 380-415V/3/50
Control Operation Wired Control Wired Control Wired Control Wired Control Wired Control Wired Control Wired Control Wired Control
Air Flow cfm 2000 2800 4400 5000 7000 7600 8000 9000
External Static Pressure Pa 50-500(100) 50-500(100) 50-500(100) 50-500(150) 50-500(150) 50-500(200) 50-500(200) 50-500(250)
(Factory Setting)"
Fan Drive Belt Driven Belt Driven Belt Driven Belt Driven Belt Driven Belt Driven Belt Driven Belt Driven
Type Saranet Saranet Saranet Saranet Saranet Saranet Saranet Saranet
Air Quality(Filter)
Qty 1 1 2 2 2 2 2 2
Unit Dimension (HxWxD) mm 1150 x 1280 x 1520 1350 x 1280 x 1520 1390 x 1965 x 1630 1390 x 1965 x 1630 1690 x 1965 x 1905 1650 x 2410 x 2030 1650 x 2410 x 2030 1950 x 2410 x 2030
Packing Dimension mm 1270 x 1320 x 1710 1410 x 1320 x 1710 1440 x 2020 x 1840 1440 x 2020 x 1840 1730 x 2120 x 2020 1740 x 2570 x 2290 1740 x 2570 x 2290 2040 x 2570 x 2290
(HxWxD)
Unit Weight Kg 350 380 590 650 840 930 940 1090
Gross Weight Kg 370 400 620 680 870 970 980 1130
Type Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll
Compressor
Qty 1 1 2 2 2 2 2 2
Refrigerant (PreCharged) Kg 9.5 11.5 5.2 + 5.2 8.5 + 8.5 8.5 + 8.5 12.0 + 12.0 10.8 + 10.8 14.0 + 14.0
Operating Range CDB up to 520C up to 520C up to 520C up to 520C up to 520C up to 520C up to 520C up to 520C

Note: 1. Gross Cooling Capacity Based on 27°C DB / 19°C WB Indoor and 35°C DB outdoor
2. All Units are being tested and Comply to ISO 5151 (Non-Ducted Unit) or ISO 13253 (Ducted Unit)
3.

ROOFTOP SERIES (Heat Pump)


7.8 TR 10.1 TR 12.7 TR 15.8 TR 19.0 TR 20.6 TR
Model
UATYQ250MCY19 UATYQ350MCY1 UATYQ450MCY1 UATYQ550MCY1 UATYQ600MCY1 UATYQ700MCY1
Nominal Cooling Capacity (Gross) Btu/h 93300 121400 152600 190000 228000 247700
W 27340 35580 44720 55690 66820 72600
Nominal Heating Capacity (Nett) Btu/h 85000 118700 142600 184000 210500 237500
W 24910 34790 41790 53930 61690 69610
Power Source V/Ph/Hz 380 -415 /3 /50 380 -415/3 /50 380 -415/3 /50
Refrigerant Type / Control R410A / EXV R410A / EXV R410A / EXV
EER (Gross) W/W 3.36 3.3 3.43 3.33 3.4 3.36
COP (Net) W/W 3.4 3.21 3.25 3.47 3.32 3.25
Sound Power Level @ 100 ESP dBA 68 72 75 82 84 87
Sound Power Level @ Std ESP dBA 73 76 80 84 84 90
EVAPORATOR

Control Air Ducted


Discharge
Operation Wired
Air Flow I/s/cfm 1560 / 3300 2030 / 4300 2670 / 5650 3160/ 6700 3445/7300 3917/8300
External Static Pressure Pa/in.wg. 147 / 0.6 147 / 0.6 147 / 0.6 206 / 0.8 196 / 0.8 206 / 0.8
Condensate Drain Size mm/in 25.4 / 1 25.4 / 1.0 25.4 / 1 25.4 / 1.0 25.4 / 1.0 25.4 / 1.0
Air Flow I/s/cfm 3884 / 8230 5664 / 12000 5710 / 12100 6090 / 12900 9534 / 20200 10006 / 21200
Sound Power Level dBA 82 83 83 87 90 90
Unit Dimension Height mm/in 1150 / 45.3 1028 / 40.5 1130 / 44.5 1048 / 41.3 1302 / 51.3 1454 / 57.3
Width mm/in 1638 / 64.5 2209 / 87.0 2209 / 87.0 2209 / 87.0 2209 / 87.0 2209 / 87.0
CONDENSER

Depth mm/in 2063 / 81.2 2113 / 83.2 2113 / 83.2 2670 / 105.1 2670 / 105.1 2670 / 105.1
Packing Height mm/in 1370 / 54 1200 / 47.3 1290 / 50.8 1270 / 50.0 1520 / 59.9 1670 / 65.8
Dimension Width mm/in 1730 / 68.2 2280 / 89.8 2280 / 89.8 2280 / 89.8 2280 / 89.8 2280 / 89.8
Depth mm/in 2300 / 90.6 2350 / 92.6 2350 / 92.6 2900 / 114.2 2900 / 114.2 2900 / 114.2
Unit Weight (Net) kg/lb 445 / 981 580 / 1278 610 / 1344 780 / 1720 830 / 1830 970 / 2139
Refrigerant Pre-charged 6.1 / 13.4 (2 X 5.8) / (2 X 7.2) / (2 X 8.7) / (2 X 10.4) / (2 X 11.6) /
(2 X 12.8) (2 X 15.9) (2 X 19.2) (2 X 22.9) (2 X 25.6)

Note: All units are being tested and comply to ISO 5151 (Non-Ducted Unit) or ISO 13253 (Ducted Unit). Cooling indoor: 27°C dB / 19°C WB, outdoor: 35°C dB
/ 24°C WB; Heating-indoor: 20°C dB, outdoor: 8°C dB / 6°C WB
* Also available in R-407 C
20

Specifications
HORIZONTAL WATER SOURCE HEAT PUMP
0.78 TR 1.49 TR 1.89 TR 2.48 TR 2.90 TR 3.55 TR
Model
MWH010DRP MWH020DRP MWH025DRP MWH030DRP MWH040DRP MWH050DRP
Nominal Cooling Capacity W 2750 5250 6650 8770 10200 12500
Nominal Heating Capacity W 3270 6100 7100 9050 10250 13000
Air Flow Rate m³/h 580 1050 1250 1700 1900 2300
Power Supply 220V~/50Hz
ESP Pa 20 30 30 30 50 50
Dimension (Length×Width×Height) mm 895×520×375 1265×655×435 1265×705×435 1390×745×435 1450×795×460 1450×795×510
Condenser Type Tube in Tube Heat Exchanger
Water Flow Rate m³/h 0.61 1.12 1.42 1.94 2.14 2.67
Water Pressure Drop kPa 13 34 60 40 40 60
Water Pipe Connection R3/4 R3/4 R3/4 R3/4 R3/4 R3/4
Compressor Rotary
Rated Power Cooling W 700 1220 1520 2230 2250 2850
Heating W 740 1280 1540 2050 2300 2780
Rated Current Cooling A 3.38 5.93 7.46 11.03 10.57 13.76
Heating A 3.45 5.95 7.54 10.17 10.77 13.43
Condensate Drain Pipe mm 20
Refrigerant Type R410A
Charge kg 0.74 1.35 1.46 0.95×2 1.3×2 1.55×2
Sound Pressure Level dB(A) 34 40 45 48 44 47
Weight kg 56 101 103 125 155 161

4.55 TR 5.40 TR 6.98 TR 8.39 TR 9.48 TR 10.66 TR


Model
MWH060DRP MWH070DRP MWH080DRP MWH100DRP MWH125DRP MWH150DRP
Nominal Cooling Capacity W 16000 19000 25000 29500 33500 37500
Nominal Heating Capacity W 16200 21500 25000 31500 35500 45000
Air Flow Rate m³/h 2800 3400 5000 6000 7000 8000
Power Supply 380V/3N/50Hz
ESP Pa 80 80 80(50/100/150) 100(80/150/200) 100(80/150/200) 150(100/200/250)
Dimension (Length×Width×Height) mm 1580×850×520 1670×855×520 1756×1000×660 1970×1150×708 1970×1150×708 2226×1200×736
Condenser Type Tube in Tube Heat Exchanger
Water Flow Rate m³/h 3.3 4.22 5.23 6.12 7.11 7.78
Water Pressure kPa 60 61 73 45 55 65
Drop
Water Pipe R3/4 R1 R1-1/4 R1-1/4 R1-1/4 Rc1-1/4
Connection
Compressor Scroll
Rated Power Cooling W 3300 4900 5600 6300 8500 9450
Heating W 3200 4800 5400 6400 8100 10300
Rated Current Cooling A 5.91 8.63 11.45 13.68 15.89 17.78
Heating A 5.83 8.41 11.11 13.87 14.46 18.89
Condensate Drain Pipe mm 20 34
Refrigerant Type R410A
Charge kg 3.5 2.8 3.5 3.2×2 3.0×2 3.7×2
Sound Pressure Level dB(A) 49 54 55 59 59 60
Weight kg 198 208 245 365 375 450

Notes:
Cooling capacity is based on 27°C (DB), 19°C (WB) air inlet temperature and 30°C water inlet temperature, 35°C water outlet temperature.
Heating capacity is based on 20°C (DB), 15°C (WB) air inlet temperature and 20°C water inlet temperature.
Contact Address

DAIKIN AIRCONDITIONING INDIA PVT. LTD.


12th Floor, Building No. 9
Tower A, DLF Cyber City
DLF Phase III, Gurgaon 122002
Haryana, India
Tel: 0124-4555444, Fax: 0124-4555333

Sales & Service Offices


Ahmedabad Cochin Kolkata Pune
Tel: 079-26583013/14 Tel: 0484-2808646 Tel: 033-4060 8019/4065 9544 Tel: 020-25560300
Bengaluru Delhi NCR Lucknow Raipur
Tel: 080-25590452/54 Tel: 011-43834400/4500 Tel: 0522-2787307/340 Tel: 0747-1115412
Bhubaneswar Ghaziabad Ludhiana Ranchi
Tel: 0674-2546476 Tel: 0120-4205851 Tel: 0161-5077028/29/30 Tel: 0763-5093703
Chandigarh Indore Mumbai Secunderabad
Tel: 0172-5089862/64 Tel: 0731-4005864 Tel: 022-30926666 Tel: 040-49134283
Chennai Jaipur Patna Vijaywada
Tel: 044-40807676 Tel: 0141-2218903/04/05/06 Tel: 0612-2582282 0866-2952224/25/26

Customer Contact Centre:


SMS: <DAIKIN> to 92 101 88 999
Give missed call: to 92 101 88 999
Customer Support no.: 011-40319300 / 1860 180 3900
Email: [email protected]
Visit us at: www.daikinindia.com
Buy at: www.mydaikinstore.com
DAIPL-2016/20-PA-1D

Disclaimer
As a continuing policy of product innovation at Daikin, the design and specifications are subject to change without prior notice. The visuals of the products
in the brochure are representative only, actual products might differ from the ones shown.

‘Products mentioned in this brochure comply with RoHS regulations as per E-waste (Management & Handling) Rules, 2011and should not be mixed with
general household waste at the end of their useful life.’ For more details kindly visit our website www.daikinindia.com or contact our customer care centre
at 011-40319300 / 1860 180 3900.

You might also like