Delta Ia-Si Diaenergie C En-Din 20180320 Web
Delta Ia-Si Diaenergie C En-Din 20180320 Web
Industrial Energy
Management System
DIAEnergie
www.deltaelectronicsindia.com
Energy Issues
As technology development and social progress continues to move forward, we are now facing
critical issues that devastate our ecosystem and accelerate the global energy crisis. Many
countries and enterprises have become aware of the severe situation and the importance of
energy savings, carbon emission reduction and environmental protection. They are actively
looking for green energy and effective solutions.
The DIAEnergie system is able to collect and analyze power usage data from different
facilities in real-time, and present detailed and easy-to-read real-time or historical energy
information for users or managers. It also sends warning messages to managers when
abnormalities occur to achieve highly-efficient operation and management. With decades of
experience in the industrial automation industry, Delta understands customer needs for real-
time energy monitoring and analysis. DIAEnergie is an excellent tool for power efficiency
enhancement on equipment and production lines, as well as building a better energy strategies
for users.
DIAEnegie features:
• Real-time Energy Management
• Energy Dashboard
• Energy Diagnosis, and Analysis Visualization
• Energy Performance Monitoring and Analytics
• Reports and Alarms
• Modbus and OPC Client Communication
1
Table of Contents
1 Introduction
5 Energy-saving Management
7 Features of DIAEnergie
14 Ordering Information
2
Smart Energy Management with DIAEnergie for Energ
DIAEnergie
Industrial Energy Management System
Ethernet
Industrial Ethernet Switch
Fiber Ring
Chemicals Air
Warehouse Compressors
3
gy Savings and Efficiency
DIAView
SCADA System
LC PLC PLC
Water Supply
Equipment
Construction and
Engineering System
Production
Production Control ERP / CRM
Facilities Wastewater
Treatment Industrial Energy
Management System
Environment,
Clean Production Health and Safety
Room Facilities
4
Energy Management
Identify Problems
and Opportunities
Determine and Diagnose
Current Conditions Determine and
■■ Ranking of energy consumption
Diagnose Current ■■ Analysis of energy consumption structure
■■ Analysis of energy performance Conditions
indicators (EnPI) ■■ Electricity cost analysis
■■ Analysis of energy saving Identify ■■ Demand analysis
performance Problems
and
Energy-Saving Opportunities
Implement
Management
Solutions
Implement Solutions and Obtain
Feedback
and Obtain Feedback
■■ Instant energy consumption
Select and
and load characteristics analysis Devise Select and Devise Solutions
■■ Analysis of energy consumption differentiation Solutions
■■ Establish EnPI
■■ EnPI monitoring ■■ Establish Energy Baseline (EB)
■■ Reports of energy consumption data
■■ Alarms
Internet
DIAEnergie
Industrial Energy
Management System
Power Meters
(Advanced / Standard Model)
RS-485 Industrial
Ethernet
Switch
Power Meters
(DIN-rail Model)
HVAC
DIAEnergie Server
Air Compressor
System
Factory
5
System Structure and Applications
Energy Management for Multiple Factories
Industrial
Power Meters
(Advanced / Standard Model)
Ethernet
Switch
RS-485
Power Meters
(DIN-rail Model)
Internet
DIAEnergie
Industrial Energy
Management System
Ethernet
Power Meters
(Advanced / Standard Model)
RS-485 Industrial
Ethernet
Switch
Power Meters
(DIN-rail Model)
Factory 2
6
Benefits and Functions
Benefits Functions
Features of DIAEnergie
Energy Dashboard
The energy dashboard displays significant power consumption in graphical visualization, such as
alarms and more, allowing users to quickly and intuitively monitor real-time power usage conditions
Overview:
• Power Usage Distribution
Diagnoses the power usage ratio of each
piece of equipment by analyzing the
proportion of energy consumption
• Power Consumption
Lists all equipment's energy consumption to
point out significant power consuming areas
in the factory
• Real-Time Power Demand
Displays real-time overall energy consumption
to ensure reasonable power usage
• Power Compare
Generates electricity statistics based on
different time rates to calculate electricity
costs and carbon emissions
7
■■ Easy settings to quickly build an energy dashboard
■■ Abundant statistical diagram tools
■■ Variousanalysis and display tools allow highly flexible usage and customization for an energy
monitoring interface
■■ Allows background image and animation input to enrich the energy dashboard
■■ Auto-play function
Trends Notes
Displays each section's overall energy consumption trend to Flexibly edits log contents for convenient job descriptions and
determine correct energy-saving strategies information transmission
8
Energy Diagnosis, Visualization and Analysis
DIAEnergie provides a rich variety of charts to view energy consumption from various perspectives.
It helps users realize changes in excessive energy consumption, and finds areas for energy savings.
9
DIAEnergie collects data from different circuits, sub systems, equipment and meters to monitor various
areas of energy consumption, such as electricity, water, fuel, gas and others, and generates easy-to-
read reports and displays for comprehensive energy visualization, comparison and analysis.
10
Energy Performance Monitoring and Analytics
DIAEnergie allows self-defined power efficiency indices for key facilities and production processes and
compares them with the indices of governmental policy, helping users to achieve energy savings.
11
Energy Performance Analytics
Through regression analysis, DIAEnergie establishes an Energy Baseline (EB) and builds a statistical
model with Energy Performance Indicators (EnPI) and affected factors, such as outdoor weather and
Coefficient of Performance (COP). It to intuitively presents energy efficiency enhancement and is the
ideal database and reference for energy management.
Energy Savings
12
Reports
■■ User-defined reports
■■ Generatesdaily, weekly, monthly,
quarterly and yearly reports
■■ Manually generates data reports
■■ Automatically sends reports by e-mail
Alarms
■■ Maximum electricity demand
■■ Current capacity and energy consumption limitations
■■ Communication errors
■■ Highlights pending alarms and alarm types
■■ Alarm notification by e-mail to relevant operators
13
OPC Client
OPC Client protocol for easier communication and integration with third-party equipment and SCADA
Systems.
Internet
RS-485
Ethernet
Power Meters
SCADA (OPC Server)
(Advanced / Standard Model)
data
Power Meters
(DIN-rail Model)
DIAEnergie
(OPC Client)
Ordering Information
Model Name Description Minimum System Requirements
■■ CPU: Intel Core i3 2.0G or above, RAM: 4G or above, Storage: 250G
DIAEnergie EMS Series B/S version,
DIAE-0200500 ■■ Operating System: Windows 7 Professional (32-bit/64-bit) SP1 / Windows Server 2012 R2 or above
with 5 equipment or 150-point authorization ■■ Database: Microsoft SQL Server 2008 R2(32-bit/64-bit) or above
■■ CPU: Intel Core i3 2.0G or above, RAM: 4G or above, Storage: 250G
DIAEnergie EMS Series B/S version,
DIAE-0201000 ■■ Operating System: Windows 7 Professional (32-bit/64-bit) SP1 / Windows Server 2012 R2 or above
with 10 equipment or 300-point authorization ■■ Database: Microsoft SQL Server 2008 R2(32-bit/64-bit) or above
■■ CPU: Intel Core i3 2.0G or above, RAM: 4G or above, Storage: 250G
DIAEnergie EMS Series B/S version,
DIAE-0201500 ■■ Operating System: Windows 7 Professional (32-bit/64-bit) SP1 / Windows Server 2012 R2 or above
with 15 equipment or 400-point authorization ■■ Database: Microsoft SQL Server 2008 R2(32-bit/64-bit) or above
■■ CPU: Intel Core i3 2.0G or above, RAM: 4G or above, Storage: 250G
DIAEnergie EMS Series B/S version,
DIAE-0102000 ■■ Operating System: Windows 7 Professional (32-bit/64-bit) SP1 / Windows Server 2012 R2 or above
with 20 equipment or 600-point authorization ■■ Database: Microsoft SQL Server 2008 R2(32-bit/64-bit) or above
■■ CPU: Intel Core i5 2.0G or above, RAM: 8G or above, Storage: 500G
DIAEnergie EMS Series B/S version,
DIAE-0105000 ■■ Operating System: Windows 7 Professional (32-bit/64-bit) SP1 / Windows Server 2012 R2 or above
with 50 equipment or 1500-point authorization ■■ Database: Microsoft SQL Server 2008 R2(32-bit/64-bit) or above
■■ CPU: Intel Core i5 2.0G or above, RAM: 16G or above, Storage: 1TB
DIAEnergie EMS Series B/S version,
DIAE-0110000 ■■ Operating System: Windows 7 Professional (32-bit/64-bit) SP1 / Windows Server 2012 R2 or above
with 100 equipment or 3000-point authorization ■■ Database: Microsoft SQL Server 2008 R2(32-bit/64-bit) or above
■■ CPU: Intel Core i5 2.0G or above, RAM: 32G or above, Storage: 1.5TB
DIAEnergie EMS Series B/S version,
DIAE-0115000 ■■ Operating System: Windows 7 Professional (32-bit/64-bit) SP1 / Windows Server 2012 R2 or above
with 150 equipment or 4500-point authorization ■■ Database: Microsoft SQL Server 2008 R2(32-bit/64-bit) or above
■■ CPU: Intel Core i5 2.0G or above, RAM: 32G or above, Storage: 2TB
DIAEnergie EMS Series B/S version,
DIAE-0120000 ■■ Operating System: Windows 7 Professional (32-bit/64-bit) SP1 / Windows Server 2012 R2 or above
with 200 equipment or 6000-point authorization ■■ Database: Microsoft SQL Server 2008 R2(32-bit/64-bit) or above
■■ CPU: Intel Core i7 2.0G or above, RAM: 32G or above, Storage: 10TB
DIAEnergie EMS Series B/S version,
DIAE-0100000 ■■ Operating System: Windows 7 Professional (32-bit/64-bit) SP1 / Windows Server 2012 R2 or above
with unlimited equipment authorization ■■ Database: Microsoft SQL Server 2008 R2(32-bit/64-bit) or above
Note :
• DIAEnergie B/S software does not include the licensed Microsoft SQL Server database.
• Maximum database size of 10 GB per database in SQL Server 2008 R2 Express.
14
Delta Electronics India Private Limited
Head Office (Gurgaon)
Plot No.43, Sector 35, HSIIDC,
Gurgaon 122001, Haryana, India.
T +91 124 - 4874900
F +91 124 - 4874945
Regional Office
North South
Chandigarh Bangalore
SCO No. 407-408, 1st Floor, Ozone Manay Tech Park, 'A' Block, 3rd Floor,
Sector 35C, Chandigarh (UT) 160035, India Survey No.56/18 & 55/9, Hosur Road, Hongasandra
T +91 172 - 4803233 Village, Bangalore 560068, Karnatka, India
T +91 80 - 67164777
F +91 80 - 67164784
East
Kolkata
Victoria Park Building, Plot No. 37/2, Hyderabad
Block GN, 9th Floor, ODC No 9A Salt Lake City, Ground & First Floor, Plot No.68,
Sector V, Kolkata 700091, West Bengal, India Shree Prashanti Sai Towers, Khairatabad, Puragutta,
T +91 33 - 40083849-60 Nagarjuna Hills Road No.1, Bahara Hills,
F +91 33 - 40083850 Hyderabad 500082, Andhra Pradesh, India
T +91 40 - 67274500
F +91 40 - 67274545
West
Mumbai
A 1619, Rupa Solitare, IT Park Building, Vishakapatnam
Plot No.MBP 2, Sector 1, MIDC, Mhape, 10-3-2, Second Floor, Waltair Uplanse Opp Sampath
Navi Mumbai 400710 Maharashtra, India Vinayak Temple, Vishakapatnam 530003, India
T +91 22- 61845200 T +91 891 - 6666867
F +91 22- 61845333
Chennai
Pune 1st Floor, ASV Chamiers Square New Door No. 87,
Arnar Business Park Office, No.805, 806, Old No. 48, Chamiers Road, Raja Annamalaipuram,
Veerbhadra Nagar, Baner, Pune 411045, Chennai, Tamil Nadu 600028, lndia
Maharashtra, India T +91 44 - 43408800
M +91 - 9763408163
Coimbatore
Gujarat No.123, Ramasamy Gownder Street,
Ahmedabad Saibaba Colony, Coimbatore 641032, India
412, 4th Floor, Aashirwad Paras, T +91 422 - 4202404
Corporate Road, Prahlad Nagar, F +91 422 - 4202302
Ahmedabad, Gujarat 380015, India
T +91 79 - 40047333
*We reserve the right to change the information in this catalogue without prior notice. DELTA_IA-SI_DIAEnergie_C_EN-DIN_20180320