MOD 4400 Moisture Analyzer Uk 1

The MOD 4400 moisture analyzer uses radio frequency dielectric sensor technology to provide fast, accurate, real-time moisture measurements for crude oil and petroleum liquids flowing through pipelines. It has several advantages over other technologies including being ultra-safe, resistant to fouling and abrasive materials, easy to install, and having low maintenance needs. The analyzer structure includes a sensor pipe section with integrated probes and temperature sensor that connect to an electronic control unit to determine moisture content. It can measure moisture levels from 0.1-100% with high accuracy.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
69 views4 pages

MOD 4400 Moisture Analyzer Uk 1

The MOD 4400 moisture analyzer uses radio frequency dielectric sensor technology to provide fast, accurate, real-time moisture measurements for crude oil and petroleum liquids flowing through pipelines. It has several advantages over other technologies including being ultra-safe, resistant to fouling and abrasive materials, easy to install, and having low maintenance needs. The analyzer structure includes a sensor pipe section with integrated probes and temperature sensor that connect to an electronic control unit to determine moisture content. It can measure moisture levels from 0.1-100% with high accuracy.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

MOD 4400 MOISTURE ANALYZER

MOD 4400
MOISTURE ANALYZER FOR CRUDE OIL
AND PETROLEUM LIQUIDS

USERS ADVANTAGES
BENEFITS
The MOD-4400 has been developed to measure on-line the moisture content in crude oil and
petroleum liquids, flowing through pipe lines. Its principle is based on Radio Frequency Dielectric
Sensors Technology, sensing by VHF radio waves and using dielectric properties.

Application of this technology provides the following users advantages:


 Fast analyses
 Accurate
 Real -Time and On-Line data about moisture
content of the liquid
 Ultra Safe
 Applicable in fuels and petroleum liquids
 Very reliable and robust, with no moving parts
 Not affected by fouling
 Resistant to abrasive materials
 Resistant to mechanical stress and impacts
 High corrosion resistance
 Usage In-line
 Easy to install
 Low cost

www.modcon-systems.com [email protected]
MOD - 4400 MOISTURE ANALYZER

ANALYZER STRUCTURE
Radio frequency (RF) Dielectric Technology in moisture analyses:

Several technologies are used to measure moisture in fluids, and are based on the relatively
high dielectric properties of water relatively to fluids, including crude oil and petroleum
liquids. Utilization of well defined radio waves gives the MOD 4400 its unique properties to
measure moisture in homogenous as well as in inhomogeneous materials.

Analyzer System
The MOD 4400 moisture analyzer is equipped
with flanges, to enable easily incorporation
into a pipe line. The analyzer and flanges can
be delivered in different sizes.

The MOD 4400 is applicable to measure


moisture in fuels and petroleum products.

The sensor is made as a pipe section with


flanges of stainless steel. The probe inside the
pipe made of stainless steel with a flat
topped U-form shape.

The probes and incorporated


temperature sensor, are connected to
its control unit to accurately
determines the moisture content of
the liquids passing through the sensor
pipe.

www.modcon-systems.com 2 [email protected]
TECHNICAL SPECIFICATION
MOD 4400 MOISTURE ANALYZER

Analyzer performance
Display range - mass water content (Weight %) 0 - 100

Measurtement Range of moisture in oil-in-water 0.1—100


emulsions, petroleum products and fuels-Mass
content water (Weight %)

Acceptable absolute error limits Δ, mass water


content, % (Δ is calculated according to the formulae 0.02+0.025*W
depending on W, where W – is the result of moisture
measurement in percent)
Sensor Operational Temperatures (°C) -20… +120
Electronic Unit Operational temperatures (°C) -20 .. +80
Temperature range of moisture meter calibration, °С + 5 .. +40
Electronic specification
Output Interface RS 485Modbus, TRU
Digital:
Current: (mA) 4-20
Supply Voltage (V) 24
Allowable (V) 18..36
Consumption Current (mA) < 200
Dust and moisture ingress protection of electronic IP 54 group
unit
Technical Properties

Length communication cable between sensor and


1.5 - 3 m
electronic unit (m)
Maximum allowable data cable length between 1000 m (RS485)
electronic unit and external indicating / control 100 m (4-20 mA Current)
device (m) - not less than:
Dimensions

Weight Sensor (Kg) 3.5


Weight Electronic Unit (Kg) 2
Sensor overall dimensions (mm) Ø 108х120
397x160x200
Dimensions electronic unit (mm) 255 x 170 x 60

www.modcon-systems.com 3 [email protected]
MOD 4400 MOISTURE ANALYZER

APPLICATIONS

The MOD 4400 is applicable in a large variety


of different applications to measure the
moisture content in fluids, including:

 On-line continuous determination of


moisture content in fuels, petroleum
liquid etc.

 On-line continuous Determination of


water content water-fuel mixtures to
increase the combustion efficiency.

SYSTEMS LTD
Registered in England and Wales with company number 07794530
10 Orange St., Haymarket London WC2H 7DQ
United Kingdom
Tel.: +44-20-808-99954

www.modcon-systems.com 4 [email protected]