Models
TAC-07CS/K TAC-09CS/K
TAC-12CS/K TAC-18CS/K
TAC-24CS/K TAC-07CHS/K
TAC-09CHS/K TAC-12CHS/K
TAC-18CHS/K TAC-24CHS/K
CONTENTS
IMPORTANT NOTICE
Technical Specifications
Model No. TAC-07CS/K TAC-07CHS/K TAC-09CS/K TAC-09CHS/K
Type Cooling Only Heating Pump Cooling Only Heating Pump
Control type Remote Remote Remote Remote
Rated cooling capacity Btu/h 7,000 7,000 9,000 9,000
Rated heating capacity Btu/h N/A 7,500 N/A 9,500
EER for cooling Btu/h.w 9.6 9.6 9.6 9.6
COP for heating W/W N/A 2.8 N/A 2.8
Moisture removal Liters/h 0.8 0.8 0.8 0.8
High dB(A) 36 36 36 36
Indoor noise level at
Med. dB(A) 32 32 32 32
cooling
Low dB(A) 29 29 29 29
Outdoor noise level dB(A) 50 50 50 50
Electrical Data
Power supply 220-240V~/50Hz
Voltage Range V
Cooling A 4.2 4.2 4.2 4.2
Rated current
Heating A N/A 4.1 N/A 4.1
Cooling W 895 895 900 900
Rated input
Heating W N/A 880 N/A 880
Refrigerating System
Refrigerant/Charge Gram R22/700g R22/700g R22/700g R22/700g
Type Rotary Rotary Rotary Rotary
Model ------------------ ----------------- ------------------ ------------------
Compressor
LRA A ------ ------- ------ ------
MFG ----------------- ----------------- ---------------- -----------------
Evaporator Louver fin and Grooved tube type (φ7)
Condenser Corrugated fin and Grooved tube type (φ9.53)
Expansion device Capillary tube
Defrosting system Microcomputer controlled reverse system
Fan System
Indoor air circulation m3/h 430 430 430 430
Indoor fan type Cross flow Cross flow Cross flow Cross flow
Cooling rpm 1000/950/900 1000/950/900 1000/950/900 1000/950/900
Indoor fan speed Heating rpm N/A 970/900/800 N/A 970/900/800
H/M/L Dry rpm 900 900 900 900
Sleep rpm 650 650 650 650
Indoor fan motor output W 12 12 12 12
3
Outdoor air circulation m /h --- --- --- ---
Outdoor fan type Propeller fan Propeller fan Propeller fan Propeller fan
Outdoor fan speed rpm 895 895 895 895
Outdoor fan motor output W 31 31 31 31
Connections
Refrigerant coupling Flare type
Gas Inches 3/8 3/8 3/8 3/8
Connecting Pipe
Liquid Inches 1/4 1/4 1/4 1/4
Size × Core
Connecting Wiring
number
Drainage Pipe O.D 16mm
Others
Suitable area m2 12~19 12~19 12~19 12~19
Net dimensions Indoor mm 710×250×179 710×250×179 710×250×179 710×250×179
(W x H x D) Outdoor mm 600×500×232 600×500×232 600×500×232 600×500×232
Indoor kg 7.5 7.5 7.5 7.5
Net weight
Outdoor kg 25 25 25 25
Packing dimensions Indoor mm 805×325×270 805×325×270 805×325×270 805×325×270
(W x H x D) Outdoor mm 745×352×542 745×352×542 745×352×542 745×352×542
Indoor kg 10 10 10 10
Gross weight
Outdoor kg 28 29 28 29
Loading Capacity 40’/40’HC 132/280/318 132/280/318 132/280/318 132/280/318
4
Downloaded from www.Manualslib.com manuals search engine
TCL Air Conditioner Service Manual
Operation Details
1 Remote controller
Remote controller
1 ON/OFF button
Used to start and stop operation
when pressed.
FEEL
SLEEP TIMER ON TMIER OFF
AUTO 2 TIMER button
COOL HIGH
DRY MID Used to select TIMER operation.
FAN LOW
HEAT SWING
3 UP button (TOO COOL button)
3 Used to increase the set room temperature
and time.
5 SLEEP FAN 7
4 DOWN button (TOO WARM button)
2 TIMER SWING 6 Used to decrease the set room temperature
and time.
8 MODE ON/OFF 1 5 SLEEP button
Used to set or cancel sleep mode operation.
4
6 VANE control button
Used to adjust airflow direction.
Note: Each mode and relevant function will be further specified in following pages.
Remote Control
The remote controller is not presetted as Cooling Only Air Conditioner or Heat Pump by manufacturer.
Each time after the remote controller replace batteries or is energized, the arrowhead will flashes on the front of
Heat or Cool on LCD of the remote controller.
User can preset the remote controller type depending on the air conditioner type you have purchased as
follows:
Press any button when the arrowhead flashes on the front of Cool , Cooling Only is set.
Press any button when the arrowhead flashes on the front of Heat , Heat Pump is set.
If you don t press any button within 10 seconds, the remote controller is preset as Heat Pump automatically.
Note :
If the air conditioner you purchased is a Cooling Only one, but you preset the remote controller as Heat Pump, it
doesn t bring any matter. But if the air conditioner you purchased is a Heat Pump one, and you preset the
remote controller as Cooling Only, then you CAN NOT preset the Heating operation with the remote controller.
Elctronic Controller
1. Safety Control
(1) Time Delay Safety Control
3 minutes delay for compressor---The compressor is ceased for 3minutes to balance the pressure in the
refrigeration cycle in order to protect the compressor.
2 minutes delay for 4-way valve---The 4-way valve is ceased for 2 minutes to prevent the
refrigerant-gas abnormal noise when the HEATING operation is OFF or switch to the other operation
mode.
20 seconds delay for indoor fan--- When the assistant thermistor turns off, the indoor fan operates in
low speed for 20 seconds to release the heat of indoor unit.
(2) Indoor Pipe Temperature Sensor Frost Prevention Control
When the indoor pipe temperature sensor reads 0℃ or below for 5 minutes, the indoor pipe temperature
sensor frost prevention control starts. The compressor and outdoor fan stop and indoor fan operates at high
speed for 3 minutes. After that, if the indoor pipe temperature sensor reads less than 5℃ this control
prolonged until the indoor pipe temperature sensor reads 5℃ or more.
(3) High Temperature Protection Control
During HEATING operation, the outdoor fan motor and compressor are controlled by the indoor pipe
temperature to prevent the high temperature of compressor.
Outdoor fan OFF: 52℃
Outdoor fan ON:48℃
Compressor OFF:62℃
Compressor ON:48℃
2. “I Feel” Mode Operation
(1) When the “I Feel” mode is selected, the operation mode and initial set temperature are determined by the
initial room temperature at start-up of the operation except to turn off the air conditioner and operates it
again.
(2) If the mode is change to “I Feel” mode from other mode, the “I Feel” mode doesn’t operate until compressor
stop for more than 3 minutes.
In the “I Feel” mode , when the controller receives the up or down single of temperature, the set
temperature can adjust by 1℃ upper or lower. The biggest you can adjust by 2℃ upper or lower.
3. “COOLING” Mode Operation
(1) When the COOLING mode is selected without setting temperature, the system will set the set temperature at
26℃ automatically with the AUTO FAN speed.
(2) When selecting the COOLING mode operation, the system will operate according to the setting by the
remote controller and the operation is as following:
7
Downloaded from www.Manualslib.com manuals search engine
TCL Air Conditioner Service Manual
Room Temp.
Set TEMP. +1℃
Set TEMP. -1℃
Time More than 2 min More than 2 min More than 2 min More than 2 min More than 2 min
Indoor Fan Set Speed Set Speed Set Speed Set Speed Set Speed
Compressor ON OFF ON OFF ON
Outdoor Fan ON OFF ON OFF ON
(3) In HEATING mode, the indoor fan motor is controlled by Cold Air Prevention Control.
(4) Cold Air Prevention Control
The function is intend to prevent cold air from being discharged when the heating operation starts or
when defrosting.
The indoor fan speed will be controlled as following:
The vane angle is at the angle C(100°).
Indoor Pipe Temperature
34℃
30℃
27℃
25℃
23℃
8
Downloaded from www.Manualslib.com manuals search engine
TCL Air Conditioner Service Manual
(5) Defrost
Defrosting of the outdoor heat exchange is controlled by the microprocessor with detection by the defrost
sensor.
Defrost starting conditions
When the conditions of a) or b) is satisfy, the defrosting operation starts.
a) Under the heating operation, the compressor cumulative operation time exceeds 50 minutes and the
temperature of the outdoor defrost sensor reads lower than -8℃
b) Under the heating operation, the compressor cumulative operation time exceeds 50 minutes, if the
indoor pipe temperature sensor reads lower than 40℃ continuously for 2minutes.
Note: If haven’t the outdoor pipe temperature sensor that use the condition b) to defrost, against
use the condition a).
Defrost terminating conditions
When the condition c) or d) is satisfy, the defrosting operation stops.
c) The outdoor defrost sensor reads 15℃ or more.
d) The defrosting time exceeds 10 minutes.
Defrosting time chart
9
Downloaded from www.Manualslib.com manuals search engine
TCL Air Conditioner Service Manual
The indoor fan motor always turns on at the set speed and the vane motor turns on at the set fattle.
7. 4-way Valve contro
HEATING ON
COOLING/DRY OFF
The 4-way valve reverses for 5 seconds right before start-up of the compressor as following chart:
COOLING/DRY HEATING
Compressor
4-way Valve
5s 5s
Outdoor Fan
8. “SLEEP” mode
When the SLEEP button is pressed, the SLEEP mode is selected as following:
The indoor fan speed is set at the super low speed.
When selecting COOLING/DRY operation with SLEEP mode, the set temperature will be raised by 1℃ 1
hour later and by 2℃ 2 hour later.
When selecting HEATING operation with SLEEP mode, the set temperature will be dropped by 1℃ 1
hour later and 2℃ 2hour later.
After the System operates in SLEEP mode for 8 hours, it will stop automatically.
9. Fan motor control
(1) Rotational frequency feedback control
The indoor fan motor is equipped with a rotational frequency sensor, and outputs signal to the
microprocessor to feedback the rotational frequency. Comparing the current rotational frequency with the
target rotational frequency, the microprocessor adjusts fan motor electric to make the current rotational
frequency close to the target rotational frequency. With this control, when the fan speed is switched, the
rotational frequency changes smoothly.
(2) When the rotational frequency feedback signal has not output for 5 seconds (or when the microprocessor
can’t detect the signal for 5 seconds), the fan motor is regarded locked-up. Then the electric current to the
fan motor is shut off. 10 seconds later, the electric current is applied to the fan motor again. During the fan
motor lock-up, the POWER indicator lamp flashes on and off to show the fan motor abnormality.
10. Auto Fan Speed Control
(1) When the auto fan speed is selected, the indoor fan motor speed is automatically controlled by the room
temperature and the set temperature.
(2) In COOLING mode, the indoor fan motor operates as following:
Fan Speed
Hi
Me
Lo
Room temperature minus set temperature: 1℃ 2℃ 4℃
(3) In HEATING mode, the indoor fan motor operates as following;
Fan Speed
Hi
Mi
Lo
Room temperature minus set temperature 1℃ 2℃ 4℃
10
Downloaded from www.Manualslib.com manuals search engine
TCL Air Conditioner Service Manual
Note: if ‘h’ is flashing and you press the ON/OFF/RUN button once, the preset temperature will appear in
11
Downloaded from www.Manualslib.com manuals search engine
TCL Air Conditioner Service Manual
the display. You can now adjust the temperature with the ▲▼ button. Press the Timer button again to
display the time, which can now also be adjusted☆. If the Timer button is pressed again, the data is stored and
the remaining time(that the air conditioner will be in operation) will appear in the display.
☆ Pressing the ON/OFF/RUN button instead of the Timer button deactivates the remote control.
Note: check that the TIMER INDICATOR on the indoor unit lights up after the timer has been set.
Press the Timer function to check the settings in the display.
13. EMERGENCY-TEST Operation
When the EMERGENCY Operation switch is pressed once, COOLING mode is selected and if in 3 seconds the
EMERGENCY Operation switch is pressed again, HEATING mode is selected. Then pressed once again, the unit
is switch off.
When the remote controller is missing, has failed or the batteries run down, press the EMERGENCY Operation
switch on the front of the indoor unit. The unit will start.
The first 30 minutes of operation will be the test run operation. The operation is for servicing. The indoor fan runs
at high speed and the system is in continuous operation. The thermostat is ON and the timer is reset to normal.
After 30 minutes of test run operation the system shifts to AUTO COOLING/HEATING mode, and the indoor fan
runs in automatic speed. The operation continues unit the EMERGENCY operation switch is pressed or a button
on the remote controller is pressed, the normal operation will start.
NOTE: Do not press the EMERGEMCY Operation switch during normal operation.
14.AUTO RESTART Function (Option)
When the indoor unit is controlled with the remote controller, the operation mode, set temperature, and the fan
speed are memorized by the indoor electric control PCB. The AUTO RESTART function sets to work the
moment power has restored after power failure. Then, the unit will restart automatically.
15. Failure Display and Handling
a) The failure of the resistance of heat sensitive:
When the resistance of heat sensitive reads the temperature is lower than -50℃ or over than 110℃ that
judge the heat sensitive is bad.
b) The Outdoor Protection Control
When the system checks the signal from outdoor of the voltage is 0V, the system delay 1second to start for
check the signal again, if checks the signal of the voltage is 0V too, that the system not to star, or operates on
normal.
c) Failure Display
When the controller is failure, the buzzer will voice long for three times, and displays the failure from the
failure lamp.
d) Failure Code
If have the digital pipe that display the failure code for digital pipe, or display for the run lamp.
Type of failure The lamp flash Display of digital pipe
The failure of room temperature sensor Once/cycle E1
The failure of indoor pipe temperature sensor Twice/cycle E2
Outdoor protection function 5 times/cycle E5
The failure of indoor fan 6 times/cycle E6
e) Failure Handling
When the room temperature sensor or the indoor pipe temperature sensor is failure, the system will be
shut off, the compressor will be OFF, and the outdoor fan and the indoor fan will be OFF. The system
doesn’t receive the signal of remoter controller except the signal of shut off it. When the failure
eliminated, the controller can operate in normal mode. before this, presses the “ON/OFF” to start the
system, and it will operate in COOLING or HEATING for 30 minutes, and follows shut off. During
12
Downloaded from www.Manualslib.com manuals search engine
TCL Air Conditioner Service Manual
this, it displays the failure and the protection is failing. You must be give the electric again to operate it.
In the failure, you can operate the FAN mode.
When the outdoor protects in the COOLING or DRY, the outdoor unit stops, the indoor fan operates in
set speed ; and in the HEATING, the outdoor unit stops, the assistant thermistor stops, the indoor fan
operates in cold air prevention control. The system doesn’t receive the signal of remoter controller
except the signal of shut off it. When the system check the voltage is 220V and the delay control is
finished, it operates at normal again.
When the indoor fan motor is failure, the compressor is stopped, the outdoor fan and indoor fan is
stopped and display the failure. The system doesn’t receive the signal of remoter controller except the
signal of shut off it.
f) Display Of The Control
In the display board the lamp from left is the POWER lamp (Red), the SLEEP lamp(Yellow), the TIMER
lamp(Yellow), the RUN lamp(Green).
(7) When gives the control electric, the buzzer voices a long for 0.3 second per cycle.
13
Downloaded from www.Manualslib.com manuals search engine
TCL Air Conditioner Service Manual
Wiring Diagram
Mode No.: TAC-07CS/K, TAC-09CS/K, TAC-12CS/K
INDOOR UNIT
PCB
CN1
Yellow/Green
transformer CN2 P2-1 Blue N
Brown 1
P2-2
N.O. 4
K1 Yellow/Green
Display PCB
CN8 COM 3 Blue
Brown
Unit
Outdoor
TH1
Room Temp.Sensor CN6
TH2 CN5 CN4 CN3
Pipe Temp.Sensor Power supply
evaporator
protector
θ
Vane Motor M
M Fan Motor
Indoor Unit
OUTDOOR UNIT
Compressor
CM
C R(M)
White S
Red Blue
θ
White
Brown Black Protector Compressor Capacitor
1
Blue Blue
N
Yellow/Green
Blue
Yellow/Green Fan Capacitor
Orange
Blue
M Yellow/Green
Fan Motor
Indoor Unit Outdoor Unit
14
WIRING DIAGRAM
MODEL: TAC-07CHS/K,TAC-09CHS/K, TAC-12CHS/K
INDOOR UNIT:
Outdoor
Room Temp. sensor CN6
Unit
TH2 Power Supply
CN5 CN4 CN3
Pipe Temp. sensor
Evaporator
θ Protecter
M
M Fan Motor
Vane Motor
Indoor Unit
OUTDOOR UNIT
Compressor
4-way Vane
CM
C R(M)
S
Blue
Blue
Red Blue
θ
Brown(White) White Protecter Compressor
1 Capacitor
Red Black
2
Yellow 3
Blue N Blue
Yellow/Green Blue Fan Capaciter
Orange
Yellow/Green Blue
M Yellow/Green
15
INDOOR UNIT
To The Outdoor
Transformer
PCB Fan Motor
White
Brown 1 FM
Blue
Blue N AC(N)
Yellow/Green Yellow/Green 5
4
N.O 3
2
SM
Relay 1
L
3
2
1
SM
Blue
N N Blue 1 2 3 4 Vane Motor
Brown Brown
L Room Temp. Sensor
Display PCB
Pipe Temp. Sensor
OUTDOOR UNIT
Compressor
CM
C R(M)
White
S
Red Blue
θ
White
Brown Black Protector Compressor Capacitor
1
Blue Blue
N
Yellow/Green
Blue
Yellow/Green Fan Capacitor
Orange
Blue
M Yellow/Green
Fan Motor
Indoor Unit Outdoor Unit
16
WIRING DIAGRAM
MODEL: TAC-18CHS/K
INDOOR UNIT:
To The Outdoor Unit
White
Brown
Red
Red CN2
P4 PCB CN1 Transformer
Yellow P3
Relay
Yellow P5 CN3
Blue AC(N) P1 P9-1 FM
Blue P9-2
P2-1 Fan Motor
Yellow/Green Yellow/Green
CN5-1 SM
Yellow/Green Yellow/Green
CN5-2 SM
Blue Blue CN8 CN7 CN6
Vane Motor
Brown Brown
Room Temp. Sensor
To O.P.T Display PCB
Pipe Temp. Sensor
OUTDOOR UNIT:
Compressor
Valve Coil
CM
C R(M)
S
Blue
Blue
Red Blue
θ
Brown(White) White Inside/Outside Compressor
1 Protecter Capacitor
Red Black
2
Yellow 3
Blue N Blue
Yellow/Green Blue Fan Capaciter
Orange
Yellow/Green Blue
17
INDOOR UNIT
Transformer
To Outdoor Unit
PCB
White N.O
1
Relay
White
Blue COM FM
Blue N
AC(N) Fan Motor
Brown L Brown 5
4
3
2 SM
Yellow/Green Yellow/Green 1
5
4
3
2
1
SM
1 2 3 4 Vane Motor
OUTDOOR UNIT
Yellow/Green
To Power Supply To Indoor Unit
White Blue
White
1 Red Fan Capacitor Conpressor
White Capacitor
Yellow/Green
Blue C1 Blue
N
Yellow
Brown C2
L Brown
Red
White
Blue
Yellow/Green
Red
Blue
Brown
Yellow/Green
L
Blue N CS R
FM CM
Brown
18
WIRING DIAGRM
MODEL: TAC-24CHS/K
INDOOR UNIT:
FM
SM
SM
OUTDOOR UNIT:
YLW/GRN
Red Red C1
2 Compressor
Yellow
3
Blue
Blue White
Red
N Blue
Brown Valve Coil
L Brown
YLW/GRN
YLW/GRN YLW/GRN CS R
To Power Supply
FM FM
Brown
L
Blue Compressor
N Blue Fan Motor
Motor
Relay
Brown Blue
O.P.T
Junction
19
EXPLOSION VIEW
Model: TAC-07CS/K, TAC-07CHS/K, TAC-09CS/K, TAC-09CHS/K, TAC-12CS/K,
TAC-12CHS/K
INDOOR UNIT:
1
2
3
4 29
5
6 28
7 27
8 26
9 25
10 24
11 23
12 22
21
13 20
14 19
18
17
16
15
20
INDOOR UNIT
2 30
3
4 29
5
28
6
27
7 26
25
8
24
9 23
10 22
11
21
12 20
13 19
18
14 17
15 16
21
EXPLOSION VIEW
Model: TAC-07CS/K, TAC-09CS/K
OUTDOOR UNIT:
7 6 5 4 3 2 1
25
24
23
22
21
20
10 11 12 13 14 15 16 17 18 19
22
EXPLOSION VIEW
Model : TAC-12CS/K, TAC-18CS/K
OUTDOOR UNIT
9 8 7 6 5 4 3 1
2
10
26
25
24
23
22
21
11 12 13 14 15 16 17 18 19 20
23
EXPLOSION VIEW
Model : TAC-24CS/K
OUTDOOR UNIT
8 7 6 5 4 3 2 1
26
25
24
9
23
22
21
20
19
18
10 11 12 13 14 15 16 17
24
EXPLOSION VIEW
Mode: TAC-07CHS/K, TAC-09CHS/K
OUTDOOR UNIT:
7 6 5 4 3 2 1
29
8
28
27
9 26
25
24
23
22
21
20
10 11 12 13 14 15 16 17 18 19
19
EXPLOSION VIEW
MODEL: TAC-12CHS/K, TAC-18CHS/K
INDOOR UNIT:
8 7 6 5 4 3 2 1
30
9
29
28
10 27
26
25
24
23
22
21
11 12 13 14 15 16 17 18 19 20
20
EXPLOSION VIEW
MODEL: TAC-24CHS/K
OUTDOOR UNIT:
8 7 6 5 4 3 2 1
29
9
28
27
26
25
24
23
22
21
20
10 11 12 13 14 15 16 17 18 19
27
Parts List
Indoor Unit- TAC-07CS/K, TAC-09CS/K
No. Part No. Part Name Q’ty Remark
1 1080030003 Installation Plate 1
2 1210250103 Base 1
3 1070020017 Cross Fan 1
4 1070100010 Bearing Mount 1
5 1210230101 Evaporator 1
6 1070250102 Water Drainage Assembly 1
7 1070320105 Vertical Vane Assembly 2
8 1070250104 Face Frame 1
9 1070320112 Screw Cover 2
10 1090320102 Display PCB 1
11 1070320115 Display PCB Box 1
12 1070250110 Display PCB Cover 1
13 1070250106 Air Filter 2
14 1070251801 Front Panel 1
15 1170120038 Power Supply Cord 1
16 1070250103 Vane 1
17 1070110008 Drainage Hose 1
18 1070040004 Cable Clamp 1
19 1170200039 Terminal 1
20 1070250109 Terminal Fixing Board 1
21 1090250602 Main PCB 1
22 1070320113 Electrical Box 1
23 1170020011 Vane Motor 1
24 1073030201 Sensor Holder 1
25 1170030047 Indoor Motor 1
26 1070320111 Indoor Motor Cover 1
27 1170240001 Transformer 1
28 1170230001 Pipe Temp. Sensor & Room 1
Temp. Sensor Assembly
29 1070320101 In And Out Pipe Fixer 1
30 1090010071 Remote Controller 1
31 1073030303 Remote Controller Supporter 1 Not shown in Explosion
31 1190060007 Indoor Carton 1 view
32 1190060008 Left Foaming 1
33 1190060009 Right Foaming 1
28
Parts List
Indoor Unit- TAC-07CHS/K, TAC-09CHS/K
No. Part No. Part Name Q’ty Remark
1 1080030003 Installation Plate 1
2 1210250103 Base 1
3 1070020017 Cross Fan 1
4 1070100010 Bearing Mount 1
5 1210230101 Evaporator 1
6 1070250102 Water Drainage Assembly 1
7 1070320105 Vertical Vane Assembly 2
8 1070250104 Face Frame 1
9 1070320112 Screw Cover 2
10 1090320102 Display PCB 1
11 1070320115 Display PCB Box 1
12 1070250110 Display PCB Cover 1
13 1070250106 Air Filter 2
14 1070251801 Front Panel 1
15 1170120044 Power Supply Cord 1
16 1070250103 Vane 1
17 1070110008 Drainage Hose 1
18 1070040004 Cable Clamp 1
19 1170200040 Terminal 1
20 1070250109 Terminal Fixing Board 1
21 1090250202 Main PCB 1
22 1070320113 Electrical Box 1
23 1170020011 Vane Motor 1
24 1073030201 Sensor Holder 1
25 1170030047 Indoor Motor 1
26 1070320111 Indoor Motor Cover 1
27 1170240001 Transformer 1
28 1170230001 Pipe Temp. Sensor & Room 1
Temp. Sensor Assembly
29 1070320101 In And Out Pipe Fixer 1
30 1090010071 Remote Controller 1
31 1073030303 Remote Controller Supporter 1 Not shown in Explosion
31 1190060007 Indoor Carton 1 view
32 1190060008 Left Foaming 1
33 1190060009 Right Foaming 1
29
Parts List
Indoor Unit- TAC-12CS/K
No. Part No. Part Name Q’ty Remark
1 1080030008 Installation Plate 1
2 1210320107 Base 1
3 1070020016 Cross Fan 1
4 1070100010 Bearing Mount 1
5 1210320601 Evaporator 1
6 1210320108 Water Drainage Assembly 1
7 1070320105 Vertical Vane Assembly 2
8 1070320107 Face Frame 1
9 1070320112 Screw Cover 2
10 1090320102 Display PCB 1
11 1070320115 Display PCB Box 1
12 1070320110 Display PCB Cover 1
13 1070320109 Air Filter 2
14 1070321501 Front Panel 1
15 1170120047 Power Supply Cord 1
16 1070320104 Vane 1
17 1070110008 Drainage Hose 1
18 1070040004 Cable Clamp 1
19 1170200039 Terminal 1
20 1070250109 Terminal Fixing Board 1
21 1090320702 Main PCB 1
22 1070320113 Electrical Box 1
23 1170020011 Vane Motor 1
24 1073030201 Sensor Holder 1
25 1170030047 Indoor Motor 1
26 1070320111 Indoor Motor Cover 1
27 1170240001 Transformer 1
28 1170230001 Pipe Temp. Sensor & Room 1
Temp. Sensor Assembly
29 1070320101 In And Out Pipe Fixer 1
30 1090010071 Remote Controller 1
31 1073030303 Remote Controller Supporter 1 Not shown in Explosion
31 1190060010 Indoor Carton 1 view
32 1190060008 Left Foaming 1
33 1190060009 Right Foaming 1
30
31
32
33
34
35
36
Part List
37
38
39
40
Part List
41
42
Part List
43