Aspen Plus Tutorial
Aspen Plus Tutorial
10
STEADY
STATE
SIMUL ATION
Version
AspenTech7
Contents
About Getting Started Modeling Processes with Electrolytes Why Use Electrolyte Simulation? ...................................................................................vi What is an Aspen Plus Electrolyte Model?.....................................................................vi Sessions in this Book ......................................................................................................vii Using Backup Files.........................................................................................................vii For More Information ................................................................................................... viii Technical Support............................................................................................................ix 1 Modeling Electrolyte Chemistry Electrolyte Chemistry Flowsheet..................................................................................1-2 Starting Aspen Plus.......................................................................................................1-3 Drawing the Graphical Simulation Flowsheet ............................................................1-5 Specifying Title, Stream Properties, and Global Options............................................1-7 Specifying Components .................................................................................................1-9 The Electrolytes Wizard ..............................................................................................1-10 Examining Generated Chemistry ...............................................................................1-15 Selecting Electrolyte Property Models........................................................................1-18 Entering Stream Data .................................................................................................1-21 Specifying the Flash Block ..........................................................................................1-22 Specifying Additional Stream Properties ...................................................................1-23 Running the Simulation ..............................................................................................1-25 Examining Simulation Results ...................................................................................1-26 Exiting Aspen Plus ......................................................................................................1-28 2 Modeling a Sour Water Stripper Sour Water Stripper Flowsheet ....................................................................................2-2 Starting Aspen Plus.......................................................................................................2-3 Drawing the Graphical Simulation Flowsheet ............................................................2-4 Specifying Title, Stream Properties, and Global Options ...........................................2-6 Specifying Components .................................................................................................2-8 The Electrolytes Wizard ................................................................................................2-9 Examining Generated Chemistry ...............................................................................2-13 Entering Stream Data .................................................................................................2-17 Specifying the RadFrac Block .....................................................................................2-19 Running the Simulation ..............................................................................................2-27 Examining Simulation Results ...................................................................................2-28 Converting to True Components.................................................................................2-34 Running the True Component Simulation .................................................................2-37 Exiting Aspen Plus ......................................................................................................2-39
iii
iv
vi
vii
viii
Aspen Plus application examples A suite of sample online Aspen Plus simulations illustrating specific processes is delivered with Aspen Plus. Aspen Plus Installation Guides These guides provide instructions on platform and network installation of Aspen Plus. The set comprises: Aspen Plus Installation Guide for Windows Aspen Plus Installation Guide for OpenVMS Aspen Plus Installation Guide for UNIX The Aspen Plus manuals are delivered in Adobe portable document format (PDF) on the Aspen Plus Documentation CD.
Technical Support
World Wide Web For additional information about AspenTech products and services, check the AspenTech World Wide Web home page on the Internet at: http://www.aspentech.com/ Technical resources To obtain in-depth technical support information on the Internet, visit the Technical Support homepage. Register at: http://www.aspentech.com/ts/ Approximately three days after registering, you will receive a confirmation e-mail and you will then be able to access this information. The most current Hotline contact information is listed. Other information includes: Frequently asked questions Product training courses Technical tips
ix
AspenTech Hotline If you need help from an AspenTech Customer Support engineer, contact our Hotline for any of the following locations:
If you are located in: North America & the Caribbean Phone Number +1-617/949-1021 +1-888/996-7001 (toll free) +54-11/4393 5308 +55-11/5506-0756 +32-2/724-0100 +44-1223/312220 +81-3/3262-1743 +54-11/4394-8621 +55-11/5506-0567 +32-2/705-4034 +44-1223/366980 +81-3/3262-1744 [email protected] [email protected] +85-2/2838-6077 +82-2/761-5800 +85-2/2833-5642 +82-2/761-5803 [email protected] [email protected] [email protected] Fax Number +1-617/949-1724 E-Mail Address [email protected]
South America (Argentina office) (Brazil office) Europe, Gulf Region, & Africa (Brussels office) (UK office) Japan Asia & Australia (Hong Kong office) (Korea office)
Chapter 1
1-1
Electrolyte Chemistry
HCL Temp = 25 C Pres = 1 bar 10 kmol/hr H2O 1 kmol/hr HCL NAOH Temp = 25 C Pres = 1 bar 10 kmol/hr H2O 1.1 kmol /hr NAOH MIX MIXED FLASH Isobaric Molar vapor fraction = 0.75 VAPOR
FLASH2
LIQUID
1-2
Chapter 1
Select AspenTech, then Aspen Plus 10.1-0, then Aspen Plus User Interface.
The Aspen Plus Startup dialog box appears. Aspen Plus displays a dialog box whenever you must enter information or make a selection before proceeding. In this simulation, you will use an Aspen Plus template.
To select the Template option, point the mouse to the Template radio button and click the left mouse button.
The New dialog box appears. You use the New dialog box to specify the Application Type and the Run Type for the new run. Aspen Plus uses the Application Type you choose to automatically set various defaults appropriate to your application.
1-3
To specify the Application Type and Run Type for the new run:
Select the Electrolytes with Metric Units template.
The default Run Type, Flowsheet, is appropriate for this session. Click OK to apply these options.
It will take a few seconds for Aspen Plus to apply these options. Note If the Connect Host dialog box appears, see Appendix A.
1-4
Chapter 1
Deselect the Automatically Assign Block Name with Prefix and the Automatically Assign Stream Name with Prefix options.
Click OK to close the Options dialog box and apply the changes.
1-5
The process flow diagram and problem definition for this session are shown in the process diagram: Electrolyte Chemistry on page 1-2.
Place the flowsheet blocks and streams to create the graphical simulation flowsheet shown below.
1-6
Chapter 1
The Electrolytes with Metric Units Application Type sets the following global defaults for electrolytes applications: METCBAR units (Metric units with temperature in degrees Centigrade and pressure in bars) Mass Flow Basis for all flow inputs
1-7
Since you chose the Electrolytes with Metric Units Application Type when you started this session, Aspen Plus has set the following defaults for calculating and reporting stream properties: Flow and Fraction Basis of Mass: Aspen Plus will report the component flow rates on a mass flow basis ELEC_E Stream Format: Aspen Plus formats the Stream Summary form for electrolytes. To review the report options specified in the selected Template:
In the menu tree of the Data Browser window, click the Report Options form in the Setup folder.
You will return to this form and specify stream properties later in this session. To move to the next required input:
Click Components on the Data Browser menu tree, then Specifications.
1-8
Chapter 1
Specifying Components
The Components Specifications Selection sheet appears. The apparent (or base) components for this session are H2O, HCl, and NaOH. Because you chose an electrolytes Application Type, water already appears on the form.
Enter the remaining components as shown below:
You can rename H20 to Water, by selecting H20 in the Component ID box, and typing Water. When the Aspen Plus dialog box appears, click the Rename button.
The Electrolytes Wizard dialog box, for defining automatic chemistry generation, appears.
1-9
The Base Components and Reactions Generation Option dialog box appears. In this dialog box, there is an option (turned off) labeled Hydrogen Ion type Hydronium ion H+. Aspen Plus can treat acidic species as either H+ or H3O+. However, use of H3O+ is strongly recommended, because the presence of H3O+ in the solution chemistry is better able to represent the phase and chemical equilibrium of almost all electrolyte systems.
Move all components to the Selected components area using Move All button .
1-10
Chapter 1
Aspen Plus generates all possible ionic and salt species, and reactions for the H2O-NAOH-HCL system. In the Reactions section in the Generated Species and Reactions dialog box, different style arrows denote the type of reaction: <<===>> Denotes ionic equilibrium or salt precipitation --->> Denotes complete dissociation
In this example, three types of reactions are generated: ionic equilibrium, complete dissociation, and salt precipitation. The dissociation of water and the dissociation of HCL are equilibrium reactions. NACL precipitation/dissolution is also an equilibrium reaction. In contrast, + NAOH dissociates completely and irreversibly into NA and OH . You can use the Remove button to eliminate any of the generated species and reactions. In this session, the NaOH and the NaOH*W salts are not relevant To remove these salts from the solution chemistry:
Select NaOH(S) and NaOH*W(S) from the Salts list.
Click the Remove button to the right of the Generated Reactions list.
1-11
Now that you have removed these salts from the Generated Aqueous Species list, Aspen Plus automatically removes all reactions involving NaOH(S) and NaOH*W(S) from the Reactions list.
Note
Any time you know that a reaction can be neglected because of expected process conditions, you should remove it from the solution chemistry, to decrease the execution time required for your simulation.
Click Next > on the Generated Species and Reactions dialog box to accept the generated species and reactions. The Simulation Approach dialog box appears, allowing you to choose between the true component approach and the apparent component approach. For this problem, you use the true component approach.
1-12
Chapter 1
When you use the true component approach, Aspen Plus solves the equations describing solution chemistry simultaneously with the unit operation equations. The unit operations deal directly with the ions and salts formed by solution chemistry. In addition, the true component approach defines how Aspen Plus reports the simulation results. Results are reported in terms of the ions, salts, and molecular components that are actually present, not in terms of the original base components. For example, the generated chemistry for this system specifies that NAOH fully + dissociates into NA and OH . If you choose the true component approach, + Aspen Plus will report NAOH flow in terms of NA flow and OH flow, not in terms of the NAOH base component flow. You can request that composition and flows also be reported in terms of the apparent (base) components. You will do this later in this session.
Select True component approach.
The Summary dialog box appears, telling you what the Aspen Plus electrolytes expert system has done.
Click Finish to close the dialog box.
On the Components Specifications Selection sheet, Aspen Plus has now added the generated electrolyte components. Since all components are databank components, Aspen Plus will automatically retrieve all relevant physical property parameters. Note that the salt NACL(S) is identified as type SOLID.
1-13
The Components Henry Comps Global sheet appears, which was defined by the Electrolytes Wizard. The Next function takes you to this form so you can see which components have been declared as Henrys Law components by the Electrolytes Wizard. If you had additional Henrys Law components in your simulation (such as nitrogen and oxygen), you would add them to the list on this form.
1-14
Chapter 1
To view a particular reaction, click the Reaction and then click the Edit button.
1-15
The Equilibrium Reaction Stoichiometry dialog box appears, with the data for the selected reaction that was generated by the Electrolytes Wizard.
1-16
Chapter 1
The optional equilibrium constant coefficients have been automatically retrieved from the Aspen Plus reactions database. The equilibrium constants are located on the Reactions Chemistry Equilibrium Constants sheet.
The Aspen Plus reactions database contains over 600 reactions, which cover virtually all common electrolyte applications.
Click on the arrow to the right of the Equilibrium reaction field to select another equilibrium reaction and view the equilibrium constants.
The second equilibrium ionic reaction is for HCL dissociation. There are no equilibrium constant coefficients for this reaction. Instead of calculating the equilibrium constant directly, Aspen Plus will calculate the chemical equilibrium from the Gibbs free energy of the participating components. The reaction for NACL(S) precipitation and its equilibrium constant coefficients are also available on this sheet. To view the equilibrium constants for the salt reactions:
Select the Equilibrium constants for: Salt option. Click on the arrow to the right of the Equilibrium reaction field to select any other salt reaction and view the equilibrium constants.
1-17
For the complete dissociation reaction of NaOH, no constants are shown. Since this is a complete dissociation reaction, it does not require an equilibrium constant. If you had your own equilibrium constant coefficients, or additional reactions you would like to include, you could enter them directly on this form.
The Properties Specifications Global sheet appears. The Electrolytes Wizard has already completed this form:
1-18
Chapter 1
The Electrolyte-NRTL activity coefficient model, ELECNRTL, is the recommended option set for simulations with electrolytes. ELECNRTL calculates liquid phase properties from the Electrolyte-NRTL activity coefficient model. Vapor phase properties are calculated from the Redlich-Kwong equation of state. ELECNRTL can represent aqueous and aqueous/organic electrolyte systems over the entire range of electrolyte concentrations with a single set of binary interaction parameters. In the absence of electrolytes, the model reduces to the standard NRTL model. Aspen Plus contains a databank of binary interaction parameters between water and over 600 electrolyte ion pairs. If the binary interaction parameters between any solvent and an electrolyte ion pair are missing from the databank, and you do not provide your own values, Aspen Plus provides reasonable default values.
Click the Next button on the Data Browser window toolbar to continue.
The Binary Interaction form appears for the binary parameters HENRY-1. Next takes you to this form so you can see the Henrys Law parameters retrieved by the electrolytes expert system. If you had your own Henrys Law parameters, you could enter them on this form.
Click the Next button on the Data Browser window toolbar to continue.
The Binary Interaction form appears for the binary parameters VLCLK-1. Next takes you to this form so that you can see the Clarke density parameters retrieved by the electrolytes expert system. If you had your own Clarke density parameters, you could enter them on this form.
From the Data Browser window, select Electrolyte then Pair.
The Electrolyte Pair forms define the electrolyte pair parameters: GMELCC, GMELCD, GMELCE , and GMELCN. If you had your own pair parameters, you could enter them on these forms.
Click the Next button on the Data Browser window toolbar to continue.
1-19
Correct representation of physical properties is essential to process modeling. For many simulations, the only physical property specification that you must provide is the selection of an option set. This dialog box shows that the Aspen Plus physical property system has many optional capabilities that you can use to increase the accuracy of the physical property calculations. Because the Aspen Plus electrolytes database has data for all components and pairs in this simulation, you dont need to provide any optional specifications or data. Now that the Components and Properties specifications are complete, you can complete the rest of the flowsheet specifications in the same way as for nonelectrolytes. There are no stream or block restrictions in using Aspen Plus electrolytes. You can use all Aspen Plus unit operation models in an electrolytes simulation.
Click OK to move to the next required input.
1-20
Chapter 1
You entered the flow specifications for this stream in terms of the base components (the apparent components). Although you are using the true component approach in this problem, Aspen Plus can accept stream specifications in terms of the apparent components as well as the true components. Aspen Plus converts the apparent component flow specifications to true component specifications.
Click the Next button on the Data Browser window toolbar to continue.
1-21
The Input Flash Options sheet for block MIX appears. As the prompt says, the zero default pressure indicates no pressure drop, which is correct for this problem.
Click the Next button on the Data Browser window toolbar to continue.
A dialog box appears telling you that all required input is complete and asking if you want to run the simulation. Before you run the simulation, you will request that certain optional properties be included in the stream report.
Click Cancel, to close the dialog box without starting a run.
1-22
Chapter 1
On the Setup Report Options Stream sheet, you specify the stream properties to be calculated and reported. For this session you will request that component mass fractions be calculated and reported.
Click the Stream tab.
You can also define additional stream properties to be calculated and reported, using Aspen Plus Property Sets. Aspen Plus provides a number of built-in Property Sets based on the Application Type you selected. You can also define your own Property Sets. In this problem, you will use a built-in Property Set to report the bubble point of each stream, and a second built-in Property Set to report the mass fractions of the apparent components in each stream.
Click the Property Sets button.
1-23
Click Close.
1-24
Chapter 1
The Control Panel appears. As the run proceeds, status messages appear in the Control Panel. It takes about a minute for Aspen Plus to process input specifications and perform the simulation. Aspen Plus has a special databank that is searched only when you use the ELECNRTL option set, as in this session. Some physical property parameters in this databank may be different from the parameters in the standard nonelectrolyte databanks. The values of the physical property parameters in the special databank were determined to provide a better fit for electrolyte systems, and are not generally applicable. When values are retrieved from this special databank, Aspen Plus generates messages in the Control Panel to inform you what properties are retrieved for which components. When the calculations finish, the message Results Available appears in the status area at the bottom right of the main window.
Use the vertical scroll bar to the right of the Control panel window to see the messages.
1-25
The Run Status Data Browser appears, indicating that the simulation completed normally.
Use the Next form button to move to the next form with results.
Since you selected the True Component approach, results for Mass Flow and Mass Frac are in terms of true components.
1-26
Chapter 1
Although you specified the flow rates in terms of the apparent components (1 kmol/hr HCL and 10 kmol/hr H2O), Aspen Plus calculated the flow rates of the true components. In stream HCL, there is only a trace of molecular HCL + _ remaining. Virtually all of the HCL is dissociated into H3O and CL . Since the HCL dissociation consumes a mole of water, the overall H2O flow rate is reduced from 180 kg/hr (10 kmol/hr) to 162 kg/hr (9 kmol/hr). You also specified the NAOH stream in terms of apparent components + (1.1 kmol/hr NAOH and 10 kmol/hr H2O). NAOH dissociates completely into NA and OH . This is reflected by the complete disappearance of molecular NAOH in this stream. Stream HCL and Stream NAOH are added together in block MIX to form Stream MIXED. Because water dissociation is included as one of electrolytes reactions, + MIX allows H3O and OH to recombine to form water. The heat of this reaction raises the temperature of Stream MIXED from 25 C (the temperature of both inlets) to 61 C. This demonstrates that the heat of electrolyte reactions (including the heat of mixing) is automatically included in Aspen Plus electrolytes calculations. Stream MIXED feeds a Flash2 block where water is boiled off. Because ions and precipitated salts are nonvolatile, Stream VAPOR only contains pure water. As the ions are concentrated in Stream LIQUID, the solubility limit of NACL in water is exceeded, causing 30 kg/hr of molecular NACL(S) to precipitate. Examine the bubble temperature for stream MIXED and stream LIQUID. Stream MIXED is subsaturated in NACL and stream LIQUID is saturated with NACL. Aspen Plus correctly calculates the bubble point of LIQUID (110 C) as greater than the bubble point of MIXED (103 C), which is greater than the boiling point of pure water at 1 bar (99.6 C). Compare the apparent mass fractions for the liquid phase with the true component mass fractions in stream LIQUID. Even though stream LIQUID has precipitated NACL(S), the apparent mass fraction of NACL(S) is zero because Aspen Plus does not consider precipitated salts to be apparent components. The apparent mass fractions of the ions NA+, H3O+, OH-, and CL- are also zero. Precipitated salts and ions can only be true components. Since the precipitated NACL(S) is not an apparent component, it is represented in the apparent component approach in terms of the original species that combined to form NACL(S): NAOH, and HCL. This is why the apparent component basis mass fraction of NAOH is 0.209 even though the true component basis mass fraction of NAOH is zero. You have now viewed the most relevant results for an electrolytes simulation. This simulation has other Results forms. You can use the browse button view them, if you choose. to
1-27
This simulation is delivered as backup file elec1 in the online Aspen Plus Examples Library. You can use this backup file to check your results.
1-28
Chapter 2
2-1
V A PO R saturated vapor distillate T em p erat u re = 1 9 0 F Pressu re = 1 5 p si T o t al f lo w = 1 0 ,0 0 0 lb /h r M ass f rac t io n H 2 S = 0 .0 0 1 M ass f rac t io n N H 3 = 0 . 0 0 1 M ass f rac t io n C O 2 = 0 . 0 0 1 M ass f rac t io n H 2 O = 0 . 9 9 7 SO U RW A T A bove S t ag e 3 9 T h eo ret ic al st ag es + c o n d en ser Pressu re = 1 5 p si Est im at ed m o lar ref lu x rat io = 2 5 Condenser temperature = 190 F
O n S t ag e 10
BO T T O M S 5 .0 ppm NH3
2-2
Chapter 2
Select AspenTech, then Aspen Plus 10.1-0, then Aspen Plus User Interface.
Note
The Aspen Plus Startup dialog box appears. Aspen Plus displays a dialog box whenever you must enter information or make a selection before proceeding. In this simulation, you will use an Aspen Plus template.
To select the Template option, point the mouse to the Template radio button and click the left mouse button.
The New dialog box appears. You use the New dialog box to specify the Application Type and the Run Type for the new run. Aspen Plus uses the Application Type you choose to automatically set various defaults appropriate to your application. To specify the Application Type and Run Type for the new run:
Select the Electrolytes with English Units template.
The default Run Type, Flowsheet, is appropriate for this session. Click OK to apply these options.
It will take a few seconds for Aspen Plus to apply these options. Note If the Connect Host dialog box appears, see Appendix A.
2-3
Deselect the Automatically Assign Block Name with Prefix and the Automatically Assign Stream Name with Prefix options.
Click OK to close the Options dialog box and apply the changes.
2-4
Chapter 2
Place the flowsheet blocks and streams to create the graphical simulation flowsheet shown below.
2-5
2-6
Chapter 2
It is always good practice to describe your problem by entering a title for the simulation. To select the template option, click the Template option button.
Enter the title Getting Started with Electrolytes Session 2.
Since you chose the Electrolytes with English Units Application Type when you started this session, Aspen Plus has set the following defaults for calculating and reporting stream properties:
Flow and Fraction Basis of Mass: Aspen Plus will report the component flow rates on a mass flow basis. ELEC_E Stream Format: Aspen Plus formats the Stream Summary form for electrolytes.
2-7
Specifying Components
The Components Specifications Selection sheet appears. The apparent (or base) components for this session are H2O, NH3, H2S, and CO2. Because you chose an electrolytes Application Type, water already appears on the form. Because the formula for ammonia is represented as H3N in the Aspen Plus databank, you must identify NH3 by entering either the component name (ammonia) or the formula (H3N).
Enter the remaining components as shown below.
The Electrolytes Wizard dialog box, for defining automatic chemistry generation, appears.
2-8
Chapter 2
Move all components to the Selected components area by using the Move All button .
2-9
Aspen Plus generates all possible ionic species and reactions for the H2O-NH3H2S-CO2 system. In the Generated Reactions list, different-style arrows denote the type of reaction. <<===>> Denotes ionic equilibrium and salt precipitation --->> Denotes complete dissociation
For this simulation, you know that ammonium carbamate formation can be neglected. To remove ammonium carbamate formation from the solution chemistry:
Select NH2COO- aqueous species.
Click the Remove button to the right of the Generated Reactions list.
Now that you have removed NH2COO- from the Generated Aqueous Species list, Aspen Plus automatically removes all reactions involving NH2COO- from the Reactions list. The salts are also not relevant. To remove the salts from the solution chemistry:
Select NH4HS(S) and NH4HCO3(S) from the Salts list.
Click the Remove button to the right of the Generated Reactions list.
2-10
Chapter 2
Note
Any time you know that a reaction can be neglected because of expected process conditions, you should remove it from the solution chemistry, to decrease the execution time required for your simulation.
In this example, only ionic equilibrium reactions are generated. The remaining six generated reactions represent partial dissociation of water, partial -2 -2 dissociation of H2S to HS and S , partial dissociation of CO2 to HCO3 and CO3 , + and partial dissociation of NH3 to NH4 .
Click Next > on the Generated Species and Reactions dialog box to accept the generated species and reactions.
The Simulation Approach dialog box appears, allowing you to choose between the true species approach and the apparent component approach. For this problem you use the apparent component approach.
2-11
When you use the apparent component approach, Aspen Plus solves the equations describing solution chemistry as part of the physical property calculations. Aspen Plus modifies the physical properties of the apparent components to account for the reactions described by the solution chemistry. The ions and precipitated salts are not seen by the unit operation models. The apparent component approach also defines how Aspen Plus reports simulation results. The component flow rates for ions are not reported. Instead, Aspen Plus reports the component flow rates of the apparent components as if no dissociation occurred. For example, the generated Chemistry for this system specifies that H2S partially -2 dissociates into HS and S . If you choose the apparent component approach, Aspen Plus will report a value for the mole flow rate of H2S that includes -2 molecular H2S, HS , and S .
Select Apparent component approach.
The Summary dialog box appears, telling you what the Aspen Plus electrolytes expert system has done.
Click Finish to close the dialog box.
On the Components Specifications form, Aspen Plus has now added the generated electrolyte components. Since all components are databank components, Aspen Plus will automatically retrieve all relevant physical property parameters.
2-12
Chapter 2
The Components Henry Comps Global sheet appears for the Henry Comps group GLOBAL, which was defined by the electrolytes expert system. Next guides you to this form so that you can see which components have been declared as Henrys Law components by the electrolytes expert system. If you had additional Henrys Law components in your simulation (such as nitrogen and oxygen), you could add them to the list on this form.
2-13
The Reaction Stoichiometry dialog box appears, with the data for the selected reaction that was generated by the Electrolytes Wizard.
View the remaining reactions using the same method.
All six reactions have equilibrium constant that have been retrieved from the Aspen Plus reactions database.
The Properties Specifications form appears. The Electrolytes Wizard has already completed this form.
2-14
Chapter 2
The Binary Interaction form appears for the binary parameters HENRY-1. Next takes you to this form so that you can see the Henrys Law parameters retrieved by the electrolytes expert system. If you had your own Henrys Law parameters, you could enter them on this form.
Click the Next button on the Data Browser window toolbar to continue.
The Binary Interaction form appears for the binary parameters NRTL-1. Next takes you to this form so that you can see the molecule-molecule interaction parameters retrieved by the electrolytes expert system. If you had your own molecule-molecule interaction parameters, you could enter them on this form.
From the Data Browser window, select Electrolyte then Pair.
The Electrolyte Pair forms define the electrolyte pair parameters: GMELCC, GMELCD, GMELCE, and GMELCN. If you had your own pair parameters, you could enter them on these forms.
Click the Next button on the Data Browser window toolbar to continue.
2-15
Correct representation of physical properties is essential to process modeling. For many simulations, the only physical property specification that you must provide is the selection of an option set. This dialog box shows that the Aspen Plus physical property system has many optional capabilities that you can use to increase the accuracy of the physical property calculations. Because the Aspen Plus electrolytes database has data for all components and pairs in this system, you dont need to provide any optional specifications or data. Now that the Components and Properties specifications are complete, you can complete the rest of the flowsheet specifications in the same way as for nonelectrolytes. You can use all Aspen Plus unit operation models in an electrolytes simulation.
Click OK to close the dialog box and move to the next required input.
2-16
Chapter 2
Enter the following mass fractions: H2O NH3 H2S CO2 0.997 0.001 0.001 0.001
2-17
On the Specifications sheet for stream STEAM, enter the following specifications: Pressure Vapor Fraction Composition H2O Mass flow value 15 PSI 1 Mass-Flow 2000 LB/HR
2-18
Chapter 2
Review the types of specifications, then close the Help window when you are ready to continue.
On the Blocks B1 Setup Configuration sheet specify the following: Number of stages 10 (9 theoretical stages and condenser) Condenser Partial-Vapor Reboiler None In the Operating Specifications list, select Reflux Ratio, Mole and specify 25 as the initial estimate for reflux ratio
2-19
The Blocks B1 Setup Streams sheet appears. Use this form to describe how the streams are connected to the RadFrac block.
Specify that Stream SOURWAT is fed to Stage 3 with the Above-Stage Feed convention. Specify that stream STEAM is fed to Stage 10 with the On-Stage feed convention.
Because stream VAPOR is connected to the vapor distillate port, Aspen Plus automatically assigns stream VAPOR as a vapor phase product from stage 1. Similarly, Aspen Plus assigns stream BOTTOMS as a liquid phase product from stage 10. The Blocks B1 Setup Streams sheet does not accept flow specifications for distillate product or bottoms product streams.
Click the Next button on the Data Browser window toolbar to continue.
The Setup Pressure sheet appears. To specify that this column operates isobarically at 15 psia:
On the first row of the form, enter a pressure of 15 PSI for Stage 1.
2-20
Chapter 2
The Required Input Complete dialog box appears, indicating that all required input specifications for RadFrac Block B1 have been entered:
You can now enter optional specifications. For this column, you have two design specifications: Spec1 Spec2 Concentration of NH3 in BOTTOMS Condenser Temperature 50 ppm 190F
To define the first design specification, click the Blocks B1 Design Specs folder.
In the dialog box that appears, click OK to accept the default ID, 1.
2-21
You must specify where this specification is to be applied, and what component and phase it applies to:
On the Components sheet, select AMMONIA as the Component.
To define another design specification, click the Design Specs folder in the Data Browser window.
2-22
Chapter 2
The Vary Object Manager appears. You need to define two manipulated variables to meet the two design specifications. In this problem you will keep free the steam feed rate and the reflux ratio specifications provided on the Blocks B1 Setup form. Aspen Plus will adjust the steam feed rate and reflux ratio to achieve the NH3 bottoms concentration specification and the condenser temperature specification.
To define the first manipulated variable, click New, then OK.
The Vary 1 form appears. On the Vary 1 form, you can tell Aspen Plus which input variables you want to keep free in order to meet the design specifications you provide.
Enter, or use List to select, the following values: Type Stream name Lower bound Upper bound Feed rate STEAM 50 lbmol/hr 200 lbmol/hr
On the Streams STEAM form you specified a Mass-Flow for Stream STEAM.
2-23
However, when you select the variable type Feed rate on the Vary 1 form, Aspen Plus assumes the Feed rate to be on a mole basis. In this case, varying the Feed rate on a mole basis from 50-200 (lbmol/hr) is equivalent to varying the Mass flow from 900-3600 (lb/hr).
To define the second manipulated variable, click the Vary folder in the Data Browser window, select New, then OK.
Enter, or use List to select, the following values: Type Lower bound Upper bound Reflux ratio 15 50
As with Feed rate, Aspen Plus always varies the reflux ratio on a mole basis, even if you specify a Mass Reflux ratio on the Blocks B1 form.
Click the Next button on the Data Browser window toolbar to continue.
2-24
Chapter 2
Aspen Plus displays the Required Input Complete dialog box, indicating that all required specifications are complete.
Click Cancel.
By default, Aspen Plus displays results only for stages that have feeds, products, heaters, or a maximum or minimum flow, and for the stages immediately above and below those stages. You will modify the default stage report so that results are reported for all stages.
To change the report, select Blocks B1 Report.
On the Report Profile Options sheet, click the All Stages radio button.
2-25
By default, Aspen Plus reports only temperature, pressure, total mole flows, enthalpy, mole fractions and K-values for the selected trays. You can request that additional properties be reported by selecting additional property sets on the Property Options sheet. You will specify that Aspen Plus report pH and true component mole fractions, using two built-in Property Sets.
Click on the Properties tab. On the Report Properties sheet, move PH and XTRUE from the Defined property sets area to the Selected property sets area using the Move button .
2-26
Chapter 2
The Control Panel appears. As the run proceeds, messages appear in the Control Panel. It takes a few minutes for Aspen Plus to process input specifications and perform the simulation. As in session 1, Aspen Plus displays messages indicating that some properties have been retrieved from a special databank. When the calculations finish, the message Results Available appears in the status area at the right of the main window toolbar.
When the message Results Available appears in the toolbar, close the Control Panel by clicking the Close button.
2-27
To display the block shortcut menu, right-click inside the RadFrac block.
The Blocks B1 Results Summary Summary sheet appears. This sheet reports the flows, temperatures, and duties for the top and bottom stage of the column.
2-28
Chapter 2
The Balance sheet appears. The block is in mass balance, but is not in enthalpy balance, because heat is being removed from the RadFrac block in the condenser. The enthalpy would have balanced if you had assigned a heat stream to the condenser duty. A summary of the results of the design specifications is located on the Design Specs Results sheet. This sheet reports the specified values and the final values for all of the design specifications. To view these results:
Click the Design Specs folder in the Data Browser window. Click the Results tab to view the Design Specs results.
2-29
A summary of the results of the manipulated variables is located on the Vary Results sheet. This sheet reports the specified bounds and the final values for all of the manipulated variables. To view these results:
Click the Vary folder in the Data Browser window.
2-30
Chapter 2
The Profiles Compositions sheet lists the mole fractions of each component for every stage. Since you chose the apparent component approach for this simulation, only the apparent components are reported. To view these results:
Click the Profiles folder in the Data Browser window.
Click the Compositions tab to view the results. Click the View list box and select Liquid.
The Profiles Properties sheet reports the actual composition of molecular components and ions. To view these results:
Click the Properties tab.
2-31
Consider the results for Stage 1. The true composition of NH3 and NH4+ sum to 0.03147 on Stage 1. This value is slightly different from the apparent mole fraction of NH3 reported on the Compositions sheet: 0.03138. This slight difference is caused by the solution chemistry. In general, the total number of moles is not conserved by solution chemistry. In this simulation, the fourth equilibrium reaction consumes 3 moles of reactants and generates two moles of products: CO2 + 2H2O <<===>>H3O+ + HCO3
-
The total number moles on an apparent component basis will be different from the total number of moles on a true component basis. Thus XNH3 (apparent basis) is not exactly equal to XNH3 (true basis) + XNH4+ (true basis).
2-32
Chapter 2
The vapor composition of apparent NH3 on stage is: YNH3 = 0.2112 From these two values, you can calculate a K-value for NH3 on stage 1: K = YNH3/XNH3 = 6.73
On the Blocks B1 Profiles form, click the K-Values tab.
The K-value for NH3 on stage 1 is 6.73. These results demonstrate that when you use apparent components, Aspen Plus also reports the K-values calculated by RadFrac (or any flash) on an apparent basis.
Close all open windows.
2-33
For the RadFrac block, you entered a desired specification of 5.0 ppm (mass) of apparent NH3 in the bottoms. However, this specification is incorrect for the true component approach, because a significant portion of the apparent NH3 is + present as NH4 . To revise the RadFrac design specification to apply to the apparent composition of NH3:
On the graphical simulation flowsheet, select the RadFrac block.
To display the block shortcut menu, right-click inside the RadFrac block.
2-34
Chapter 2
The Design Spec Specifications sheet appears. You will modify Design Spec 1 to specify a stream property for the apparent mass fraction of NH3.
In the Type field, use the drop-down list and select Property value to replace Mass purity. In the Value field, enter 5.0E-6. In the Property set field, right-click and select New from the list.
On the Feed/Product Streams sheet, move the BOTTOMS stream from the Available streams area to the Selected stream area using the Move button .
2-35
The Properties Prop-Sets XNH3APP form appears. Aspen Plus will use this Property Set to calculate the apparent mass fraction of NH3 in the liquid phase.
Click on the Search button. In the Search Physical Properties dialog box, type apparent component mass fraction in the field and click on the search button. Select Apparent component mass fraction alias WXAPP from the list of Physical property names that appears.
Click in the Phase field on the Qualifiers sheet, and select Liquid from the list. Click in the Component field, and select NH3 from the list.
2-36
Chapter 2
When the calculations finish, the message Results Available appears in the status area at the right of the Main Window toolbar.
Close all open windows, and the Control Panel.
To display the block shortcut menu, right-click inside the RadFrac block.
2-37
This form reports the liquid phase mole fraction for all components, including the ions. Stage 1 reports the following compositions: X NH3 = 0.02093 X NH4+ = 0.01054
Select Vapor from the View field in the upper left corner of the sheet.
Note that all ions have a mole fraction of zero in the vapor phase. Stage 1 reports the following composition: Y NH3 = 0.21115 From these values, a stage 1 K-value for NH3 can be calculated. K = YNH3/XNH3 = 10.09
On the Blocks B1 Profiles form, click the K-Values tab.
On stage 1, the reported K value for NH3 matches the value you just calculated. This demonstrates that when true components are used, the K-values calculated by RadFrac (or any flash) are also reported on a true basis. Note that the K-value calculated in the apparent simulation is not equal to the K-value calculated in the true simulation due to the partial dissociation of ammonia. The table below compares a number of the values calculated in the true component simulation and the apparent component simulation.
Apparent Condenser duty (BTU/HR) Condenser Temperature (F) Bottom Stage Temperature (F) Steam Feed Rate (lb/hr) Molar Reflux Ratio -1.46E6 190 213 1787 29.5 True -1.46E6 190 213 1787 29.4
All values are virtually identical. This demonstrates that the results calculated by the true approach and the apparent approach are equivalent, even if they are not numerically equal.
2-38
Chapter 2
When the dialog box appears asking if you want to save the run, select No to exit without saving the run; or select Yes if you want to save the run, and enter a Run ID when prompted.
This simulation (using the apparent approach) is delivered as backup file elec2 in the Aspen Plus Examples Library. You can use this backup file to check your results.
y y y y
2-39
2-40
Appendix A
If you choose Local PC as the server for the simulation engine, you do not need to enter any more information into the dialog box.
Click OK to continue.
If you choose UNIX host, OpenVMS host, or Windows NT server as the server for the simulation engine:
Enter the node name of the computer on which the Aspen Plus simulation engine will execute.
Enter your User Name, Password, and Working Directory, and click OK. When the network connection is established, a message box appears saying Connection Established.
A-1
If the Connection Established message does not appear, see your Aspen Plus system administrator for more information on network protocols and host computers for the Aspen Plus simulation engine.
A-2