The netTAP gateway family converts two protocols simply and efficiently into each other. Whether it’s a simple serial bus,
a classic Fieldbus or one of the many Real-Time-Ethernet protocols, netTAP provides a common platform for a transparent
conversion of any protocol of the industrial automation. For plants recently upgraded with Fieldbus or modernized with
Real-Time-Ethernet netTAP enables the use of existing and proven field devices still by simply interfacing between the
new and old technology.
The modular gateway design combines the two network interfaces in a DIN-rail mountable housing. netTAP is configured
and diagnosed by an universal FDT/DTM technology based configuration tool. LED indicators are visualizing status infor-
mation for rapid on-site diagnostics. The protocol conversions are pre-programmed and loaded as firmware into the device
on demand. Conversions needing the same physical network interface can be managed by a single device variant. So a
device can be for example a PROFIBUS slave on one hand or a PROFIBUS master by a simple firmware change on the
other.
netTAP 50 – The Low-Cost Gateway
netTAP 50 is a protocol converter for simple conversions. It supports conversions of 1-port Realtime Ethernet to Fieldbus
to serial automation protocols and realizes slave to slave and slave to master combinations. As a master netTAP 50
provides full master functionality to a one slave. This enables an effortless integration of a single field device into any
higher-level network.
The design impresses with a cost-optimized, compact hardware reduced to the very basic needs of a protocol converter.
The converter addresses a market segment that sets the focus on cost savings rather than on a fully-featured functionality.
The cost reduced design combined with its countless conversions is making netTAP 50 an attractive gateway in terms of
price and universality.
netTAP 100 – Gateway without limits
netTAP 100 is the protocol converter for sophisticated conversions and manages next to serial to Fieldbus to 2-port
Realtime Ethernet also Fieldbus to Fieldbus conversions. It supports slave and master functionality in any combination.
There are no restrictions on the master functionality when it is master licensed.
A memory card slot allows the user to save the firmware and configuration data on a removable card. In case of a field
failure all that is necessary to bring the plant back on line in seconds is to move the memory card from the old netTAP 100
onto a spare unit.
netTAP 100 allows the user to create own serial protocols with the scripting language Lua based netSCRIPT. A full fea-
tured development environment is included in the delivery. It allows the comfortable and rapid programming of any propri-
etary serial protocol and the I/O data pre-processing during the conversion into the other field protocol.
netTAP 50 netTAP 100
Highlights Highlights
Cost optimized, Fieldbus to Fieldbus conversion
compact design netTAP 50 netTAP 100 2-port Realtime-Ethernet to
1-port-Real-Time-Ethernet Backup Fieldbus conversion
Project
to Fieldbus, Data
serial RS232/422/485 to Fieldbus RS232/422/485 to
or 1-port Real-Time-Ethernet
Controller/PLC Fieldbus or 2-port Realtime-
Ethernet conversion
Slave to Slave, Controller/PLC
Slave to Master conversions Master and Slave functionality
in any combination
One configuration tool
for all conversions Own serial protocols with
netSCRIPT scripting language
Ethernet service port
- Network configuration and diagnostics
Memory card option for saving
Single I/O-Device - netSCRIPT editor/debugger netTAP 100 firmware and configuration
One configuration tool for all
conversions
USB service port
I/O-Devices
Protocol Cyclic Process Data max. Parameter Value Protocol Cyclic Process Data max. Parameter Value
Technical Data netTAP 50
Master * Slave Diagnostic Interface Ethernet, RJ45 female connector Technical Data netTAP 100 Master Slave Diagnostic Interface Mini-USB
ASCII 2024 Bytes I/O-Data Display SYS, COM, LINK, Rx/Tx, protocol specific ASCII 2024 Bytes I/O-Data Display SYS, COM, LINK, Rx/Tx, protocol specific
CANopen 7168 1024 Bytes I/O-Data Configuration SYCON.net, Windows® 2000, XP, 7
CANopen 1024 1024 Bytes I/O-Data Configuration SYCON.net, Windows® 2000, XP, 7
CC-Link 736 Bytes I/O-Data Power Supply 18 … 30 V / 130 mA @ 24 V
CC-Link 736 Bytes I/O-Data Power Supply 18 … 30 V / 130 mA @ 24 V DeviceNet 7168 510 Bytes I/O-Data Connector Mini-COMBICON 2-pin
DeviceNet 510 510 Bytes I/O-Data Connector Mini-COMBICON 2-pin EtherCAT 11520 400 Bytes I/O-Data Operating Temperature 0 ... 60 °C
Ethernet/IP 1008 1008 Bytes I/O-Data Operating Temerature 0 ... 60 °C Ethernet/IP 11520 1008 Bytes I/O-Data Size (L x W x H) 100 x 52 x 70 mm (without connector)
Modbus RTU 11520 11520 Bytes I/O-Data Mounting DIN-Rail, DIN EN 60715
Modbus RTU 1024 1024 Bytes I/O-Data Size (L x W x H) 100 x 25 x 70 mm (without connector)
Modbus TCP 11520 11520 Bytes I/O-Data Weight 150 g
Modbus TCP 1024 1024 Bytes I/O-Data Mounting DIN-Rail, DIN EN 60715 netSCRIPT 2048 Bytes I/O-Data CE-Sign yes
PROFIBUS 488 488 Bytes I/O-Data RS232/485/422 not electrically isolated POWERLINK 2980 Bytes I/O-Data UL UL 508
PROFINET-IO 2048 2048 Bytes I/O-Data Weight 80 g PROFIBUS 7168 488 Bytes I/O-Data Emission CISPR 11 class A
PROFINET-IO 11520 2048 Bytes I/O-Data Noise Immunity EN 61131-2:2003
* Master functionality to one slave CE-Sign yes
SERCOS III 11520 396 Bytes I/O-Data Card slot MMC memory card
The effectively convertible number of I/O data of a protocol Emission CISPR 11 class A
The effectively convertible number of I/O data of a protocol conversion is
conversion is determined by the protocol with the lower I/O Noise Immunity EN 61131-2:2003 determined by the protocol with the lower I/O data number.
data number.
Technical Data/
Product Overview
Supported Protocol Conversions
TCP
* Master/Slave
Master/Slave Master/Slave Master/Slave Master/Slave * Master/Slave * Master/Slave Master/Slave
Master/Master Master/Slave
Slave/Slave Slave/Slave Slave/Slave Slave/Slave Slave/Slave Slave/Slave Slave/Slave
Slave/Slave Slave/Slave
Slave/Master Slave/Master Slave/Master Slave/Master Slave/Master Slave/Master Slave/Master
Slave/Master
Slave/Slave Slave/Slave Slave/Slave Slave/Slave * Slave/Slave * Slave/Slave * Slave/Slave Slave/Slave
Slave/Slave
Slave/Master Slave/Master Slave/Master Slave/Master Slave/Master Slave/Master Slave/Master Slave/Master
* Master/Slave
Master/Slave Master/Slave Master/Slave Master/Slave * Master/Slave * Master/Slave Master/Slave
Master/Master Master/Slave
Slave/Slave Slave/Slave Slave/Slave Slave/Slave Slave/Slave Slave/Slave Slave/Slave
Slave/Slave Slave/Slave
Slave/Master Slave/Master Slave/Master Slave/Master Slave/Master Slave/Master Slave/Master
Slave/Master
* Master/Slave * Master/Slave * Master/Slave Master/Slave * Master/Slave * Master/Slave
* Master/Slave Master/Slave
Master/Master Master/Master Master/Master Master/Master Master/Master Master/Master Master/Slave
Slave/Slave Slave/Slave
Slave/Slave Slave/Slave Slave/Slave Slave/Slave Slave/Slave Slave/Slave Slave/Slave
Slave/Master Slave/Master
RTU Slave/Master Slave/Master Slave/Master Slave/Master Slave/Master Slave/Master
* Master/Slave
Master/Slave Master/Slave Master/Slave Master/Slave * Master/Slave * Master/Slave Master/Slave
Master/Master Master/Slave
Slave/Slave Slave/Slave Slave/Slave Slave/Slave Slave/Slave Slave/Slave Slave/Slave
Slave/Slave Slave/Slave
Slave/Master Slave/Master Slave/Master Slave/Master Slave/Master Slave/Master Slave/Master
Slave/Master
* Serial ASCII/ * Serial ASCII/ * Serial ASCII/ Serial ASCII/ * Serial ASCII/ * Serial ASCII/ * Serial ASCII/
Serial ASCII/
Slave Slave Slave Slave Slave Slave Serial ASCII/ Slave
ASCII Serial ASCII/ Serial ASCII/ Serial ASCII/ Serial ASCII/ Serial ASCII/ Serial ASCII/ Slave Serial ASCII/
Slave
Serial ASCII/
Master Master Master Master Master Master Master
Master
Custom Script/ Custom Script/ Custom Script/ Custom Script/ Custom Script/ Custom Script/ Custom Script/ Custom Script/
Custom Script/
Slave Slave Slave Slave Slave Slave Slave Slave
netSCRIPT Custom Script/ Custom Script/ Custom Script/ Custom Script/ Custom Script/ Custom Script/
Slave
Custom Script/ Custom Script/
Master Master Master Master Master Master Master Master
Note: All technical data can be altered without notice.
* Conversions marked in red color are available on netTAP 50 and netTAP 100 both
netTAP 100: A master license needs to be ordered separately for conversions with master functionality (except Modbus)
netTAP 50: Master functionality supported to one slave only (except Modbus)
Headquarters Subsidiaries
Germany China India Japan Switzerland
Hilscher Gesellschaft für Hilscher Systemautomation (Shanghai) Co. Ltd. Hilscher India Pvt. Ltd. Hilscher Japan KK Hilscher Swiss GmbH
Systemautomation mbH 200010 Shanghai New Delhi - 110 025 Tokyo, 160-0022 4500 Solothurn
Rheinstrasse 15 Phone: +86 (0) 21-6355-5161 Phone: +91 11 40515640 Phone: +81 (0) 3-5362-0521 Phone: +41 (0) 32 623 6633
65795 Hattersheim
Fax: +49 (0) 6190 9907-50 France Italy Korea USA
E-Mail: [email protected] Hilscher France S.a.r.l. Hilscher Italia srl Hilscher Korea Inc. Hilscher North America, Inc.
Web: www.hilscher.com 69500 Bron 20090 Vimodrone (MI) Suwon, 443-734 Lisle, IL 60532
Phone: +33 (0) 4 72 37 98 40 Phone: +39 02 25007068 Phone: +82 (0) 31-695-5515 Phone: +1 630-505-5301
E-Mail: [email protected] E-Mail: [email protected] E-Mail: [email protected] E-Mail: [email protected]
Distributors (more information on www.hilscher.com)
Australia Brazil Finland Norway Russia Spain UK
Fieldbus Specialists SoftBrasil Automacao Ltda. Elkome Systems Oy AD Elektronikk AS ProSoft Ltd. Sistel Control S.L. Miles Industrial Electronics Ltd
03/2011 V3 GB
Austria Czech Republic France Poland Singapore Novatronic Sistemas S.L.
VIPA Elektronik-Systeme GmbH ZPA-Industry a.s. HIGH`COM RAControls SP. z o.o Vector Info Tech Pte Ltd Sweden
Belgium Denmark Netherlands Portugal South Africa Novotek Sverige AB
Telerex N.V. Novotek Denmark A/S Telerex Nederland B.V. Novatronic Sistemas S.L. Innomatic