Mass Timber Pitched Roof Ridge, SOLITEX ADHERO

This document provides construction details for a mass timber pitched roof system using Pro Clima air and vapor barrier products. It depicts a ventilated ridge with SOLITEX EXTASANA ADHERO vapor permeable membrane adhered over insulation and under the roofing material. A cavity space is provided above the membrane with TESCON EXTORA tape used to seal the membrane joints. Notes specify using non-combustible insulation where required and that structural and fire engineering approval is needed.

Uploaded by

dean
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
126 views2 pages

Mass Timber Pitched Roof Ridge, SOLITEX ADHERO

This document provides construction details for a mass timber pitched roof system using Pro Clima air and vapor barrier products. It depicts a ventilated ridge with SOLITEX EXTASANA ADHERO vapor permeable membrane adhered over insulation and under the roofing material. A cavity space is provided above the membrane with TESCON EXTORA tape used to seal the membrane joints. Notes specify using non-combustible insulation where required and that structural and fire engineering approval is needed.

Uploaded by

dean
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

W1511-1 Pro Clima - Mass Timber Pitched Roof

With SOLITEX EXTASANA ADHERO®

Scale 1:10 @ A4 paper

Typical German Venitlated Ridge


For Australian and New Zealand ridge options see:
https://proclima.com.au/construction-details-library-roof/
https://proclima.co.nz/construction-details-library-roof/

Ventilated ridge

pro clima
TESCON EXTORA®

Cavity (min. 20mm)


Wide width batten : 70mm
wide timber or similar width metal batten
when used over semi rigid fibrous
insulation

pliable building membrane


(underlay), pro clima Min. 20mm
SOLITEX MENTO® family

Vapour permeable fibrous insulation*

Full-surface adhesive air


sealing membrane overlap with
Optional insulated
100mm pro clima SOLITEX EXTASANA
service cavity (45mm)
ADHERO®

Cross laminated
timber

*Notes:
1) Non-combustible insulation types may be required by local regulations.

1 of 2
Title: Mass Timber Ridge
With SOLITEX EXTASANA ADHERO®
ID: W1511-1 Issued: 29/03/2023 Revision:
© This drawing is the property of Pro Clima NZ Ltd &/or Pro Clima Australia Pty Ltd and must not be copied without permission. This drawing is a guideline only and subject to change without notice.
Thermal and hygrothermal performance should match specific design, materials and climate requirements. These can be confirmed by hygrothermal analysis using software e.g. WUFI®. Structural, fire and
www.proclima.co.nz acoustic engineering design and the incorporation of building services (plumbing and electrical) should be signed-off by a suitably qualified engineer to ensure compliance with all health and safety
www.proclima.com.au requirements.
W1511-2 Pro Clima - Mass Timber Pitched Roof - 3D
With SOLITEX EXTASANA ADHERO®

Scale 1:10 @ A4 paper

Wide width batten : 70mm


wide timber or similar width
metal batten when used over
semi rigid fibrous insulation

pro clima
TESCON EXTORA®
pliable building membrane
(underlay), pro clima
SOLITEX MENTO® family

Vapour permeable
fibrous insulation*

Overlap with 100mm pro clima SOLITEX


EXTASANA ADHERO®

*Notes:
1) Non-combustible insulation types may be required by local regulations.

2 of 2
Title: Mass Timber Ridge - 3D
With SOLITEX EXTASANA ADHERO®
ID: W1511-2 Issued: 29/03/2023 Revision:
© This drawing is the property of Pro Clima NZ Ltd &/or Pro Clima Australia Pty Ltd and must not be copied without permission. This drawing is a guideline only and subject to change without notice.
Thermal and hygrothermal performance should match specific design, materials and climate requirements. These can be confirmed by hygrothermal analysis using software e.g. WUFI®. Structural, fire and
www.proclima.co.nz acoustic engineering design and the incorporation of building services (plumbing and electrical) should be signed-off by a suitably qualified engineer to ensure compliance with all health and safety
www.proclima.com.au requirements.