The document provides installation and operation instructions for indoor air conditioning units. It includes parts and functions, safety information, maintenance instructions, fault diagnosis, installation procedures, electrical wiring details, test run procedures, and instructions for moving or scrapping the unit.

Uploaded by

marianin1
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
77 views24 pages

AAA2R0E1D00 AC482MDERA UMv1.0 PDF

The document provides installation and operation instructions for indoor air conditioning units. It includes parts and functions, safety information, maintenance instructions, fault diagnosis, installation procedures, electrical wiring details, test run procedures, and instructions for moving or scrapping the unit.

Uploaded by

marianin1
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 24

Indoor Unit Operation & Installation Manual

AC092MDERA
AC122MDERA
AC162MDERA
AC182MDERA
AC242MDERA
AC282MDERA
AC302MDERA
AC382MDERA
AC482MDERA

No. 0150538640

• Please read this manual carefully before using.


• Keep this operation manual for future reference.
Original instructions
User Manual
Contents
Parts and Functions����������������������������������������������������������������������������������������������������������������������������������������������������������1
Safety��������������������������������������������������������������������������������������������������������������������������������������������������������������������������������2
Maintenance����������������������������������������������������������������������������������������������������������������������������������������������������������������������5
Fault Checkup�������������������������������������������������������������������������������������������������������������������������������������������������������������������6
Installation Procedures������������������������������������������������������������������������������������������������������������������������������������������������������7
Electrical Wiring���������������������������������������������������������������������������������������������������������������������������������������������������������������14
Test Run & Fault Code����������������������������������������������������������������������������������������������������������������������������������������������������18
Move and scrap the air conditioning��������������������������������������������������������������������������������������������������������������������������������19

• The indoor unit, suspended to ceiling or standing on floor, renders considerable operating ease and flexibility.
• With its ultra-thin design, dazzling exterior and space economy, the indoor unit fits in well with indoor scenarios.
• Boasting superb power and fast temperature tuning, the indoor unit delivers undeniable comforts and pleasures
whenever you feel like wanting the same.
• Highly efficient silencing technology greatly reduces operating noises and delivers natural comforts.
• In case of sudden blackout during operation, the indoor unit, with its Blackout Retrieval function preset, is capable of
retrieving its operating status prior to the blackout when power supply is restored.
• Integrated Control is available with the indoor unit (through integrated controller).
• Multi-connected unit series features "uniform control mode", i.e., all indoor units are restricted to run on heating or
cooling mode at the same time.
• For the protection of compressor, the air conditioning unit shall be powered for over 12 hours.

Warning
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons
in order to avoid a hazard.
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
• Children should be supervised to ensure that they do not play with the appliance.
• This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.
• The appliances are not intended to be operated by means of an external timer or separate remote-control system.
• Keep the appliance and its cord out of reach of children less than 8 years.

Operating Range of Air Conditioner


Max. DB:32°C WB:23°C
Indoor
Cooling Min. DB:18°C WB:14°C
dry Max. DB:43°C WB:26°C
Outdoor
Min. DB:-5°C
Max. DB:27°C
Indoor
Min. DB:15°C
Heating
Max. DB:21°C WB:15°C
Outdoor
Min. DB:-15°C
Parts and Functions
Indoor unit

Operating Control Panel

Wi-Fi
Indicator
Human Sensor Lamp

Operation Control Panel Display


Indicator
Lamp
Cover Plate Emergency
Switch
Front Panel

Inlet Grill (Filter inside) Remote Receiver

Note:
For the wired control type unit, the unit state should be checked by the wired controller, instead of the
remote receiver. And if you set the TIMER function, the TIMER LED on the remote receiver will not be on.

Wind Direction Regulation


Auto Airflow
Press Up/Down Airflow button, outlet guide plate changes posture as follows:
COOL/DRY/FAN: Upper/Lower Guide Plates Swing Range:
1 2 3 4 5 1

2
HEAT: 3
5 4 3 2 1
4
5
1 Air Guide Plate Positioning Swing Range
2 ① ①→③
3 ② ①→③
③ ②→④
4
④ ③→⑤
5 ①→⑤

(All Covered)

Fixing Outlet Direction


Decide upon a proper angle when guide plates move in auto airflow mode and press Wind Direction button to fix wind
direction.
Upper/lower flaps commanding airflow directions shall be positioned as follow when fixing wind directions:
Upward in cooling and drying mode
Downward in heating mode
• Make sure that outlet plates or flaps are adjusted only and always through the Wind Direction button on remote control;
manual adjusting may cause malfunction.
• Outlet guide plates constantly positioned downwards are prohibited when cooling and drying modes are activated as
vapor close to outlet grille may condense and resultant water may drip down from the unit.
• Please pay close attention to temperature regulation values when operating the unit in places where infants, children,
old people and patients are to be found.

1
Safety
• If the air conditioner is transferred to a new user, this manual shall be transferred to the user, together with the
conditioner.
• Before installation, be sure to read Safety Considerations in this manual for proper installation.
• The safety considerations stated below is divided into " WARNING" and " CAUTION". The matters on severe
accidents caused from wrong installation, which is likely to lead to death or serious injury, are listed in " WARNING".
However, the matters listed in " CAUTION" are also likely cause the severe accidents. In general, both of them are
the important items related to the security, which should be strictly abided by.
• After the installation, perform test run to make sure everything is in normal conditions, and then operate and maintain
the air conditioner in accordance with the User Manual. The User Manual should be delivered to the user for proper
keeping.

WARNING
• Please ask the special maintenance station for installation and repair. Water leakage, electric shocks or fire accidents
might be caused from improper installation if you conduct the installation by your own.
• The installation should be conducted properly according to this manual. Water leakage, electric shocks or fire accidents
might be caused from improper installation.
• Please make sure to install the air conditioner on the place where can bear the weight of the air conditioner. The air
conditioner can't be installed on the grids such as the non-special metal burglar-proof net. The place with insufficient
support strength might cause the dropdown of the machine, which may lead to personal injuries.
• The installation should be ensured against typhoons and earthquakes, etc. The installation unconformable to the
requirements will lead to accidents due to the turnover of the machine.
• Specific cables should be used for reliable connections of the wirings. Please fix the terminal connections reliably to
avoid the outside force applied on the cables from being impressed on the cables. Improper connections and fixings
might lead to such accidents as heating or fire accidents.
• Correct shapes of wirings should be kept while the embossed shape is not allowed. The wirings should be reliably
connected to avoid the cover and the plate of the electrical cabinet lipping the wiring. Improper installation might cause
such accidents as heating or fire accidents.
• While placing or reinstalling the air conditioner, except the specific refrigerant (R410A), don't let the air go into the
refrigeration cycle system. The air in the refrigeration cycle system might lead to the cracking or personal injuries due to
abnormal high pressure of the refrigeration cycle system.
• During installation, please use the accompanied spare parts or specific parts. If not, water leakage, electric shocks, fire
accidents or refrigerant leakage might be caused.
• Don't drain the water from the drainpipe to the waterspout where may exist harmful gases such as sulfureted gas to
avoid the harmful gases entering into the room.
• During installation, if refrigerant leakage occurs, ventilation measures should be taken, for the refrigerant gas might
generate harmful gases upon contacting the flame.
• After installation, check if any refrigerant leakage exists. If the refrigerant gas leaks in the room, such things as air
blowing heaters and stoves, etc. may generate harmful gases.
• Don't install the air conditioner at the places where the flammable gases may leak. In case the gas leakage occurs
around the machine, such accidents as fire disasters may be caused.
• The drainpipe should be properly mounted according to this manual as to ensure the smooth drainage. In addition, heat
preservation should be taken to avoid condensation. Improper drainpipe mounting might cause water leakage, which
will get the articles at home wet.
• The refrigerant gas pipe and liquid pipe should be heat insulated to preserve heat. For inappropriate heat insulation, the
water caused from the condensation will drop to get the article at home wet.

CAUTION
• The air conditioner should be effectively grounded. Electric shocks may occur if the air conditioner is ungrounded or
inappropriately grounded. The wire for earthing shouldn't be connected to the connections on the gas pipe, water pipe,
lightning rod or telephone.
• The breaker for electricity leakage should be mounted. If not, accidents such as electric shocks may happen.
• The installed air conditioner should be checked for electricity leakage by being powered.
• If the ambient humidity bigger than 80%, when the water discharge hole be blocked or the filter becomes dirty, or airflow
speed change, there maybe leads to condensing water drop down, and at the same time there maybe some drops of
water spit out.

2
Safety
Items with this warning sign concerning the product's safety and the personal security must be performed
strictly.
Items with this forbidding sign refer to absolutely forbidden behaviors. If not, they may cause machine damage
or endanger operator's personal safety.

Clean the filter regularly. Don't touch the outlet while the flap is moving. Don't put
Cooling or heating performance will be degraded if the filter anything in the grid in case danger may occur.
is blocked, resulting in large power consumption, failure,
and water dripping at freezing.

Avoid cold wind from blowing out. Changing Wind Speeds:


During heating running, the fan of indoor units will not In the state of refrigerating, with automatic blowing mode,
rotate immediately as to prevent cold wind from blowing the wind speed automatically decreases when the room
out. temperature approaches the setting.
wait for a moment
In the state of heating, when the room temperature reaches
the setting temperature the compressor stops working and
the fan turns to low wind or stops. Wind speed changes
automatically in the dehumidifying mode.

Regulating Wind Direction: Defrosting:


It is recommended not to make the wind deflector During heating running, the air conditioner would defrost
downwards for a long time to avoid condensation at air automatically if there is frost on heat exchanger of outdoor
outlet port during refrigerating or dehumidifying. units.
Water dropping might appear at the air outlet port in Do not rotate fans of both indoor units and outdoor units
refrigerating or dehumidifying mode. during defrosting.
After finishing defrosting, the air conditioner will resume
running automatically.
The machine operation must be controlled by the control. Hints:
As air conditioners absorb heat from the environment and
release it to the room, heating effects will be influenced by
the temperature in and out of the room.

Notices during Operation


• It is not allowed to put any heating apparatus under the indoor units, for the heat may cause distortion of the units.
• Pay attention to the aeration condition to avoid anoxic symptom.

• Flammable apparatus should not be placed in the place where the air conditioner wind could reach directly, or
incomplete burning of the apparatus may be caused.

• Check the mount table of the air conditioner for damage for a long period of operation.
If placed on the damaged table, the unit may drop down causing damage.
• Plants and animals should not be put to the place where wind of the air conditioner blows directly, otherwise damage
to them may be caused.

3
Safety
Notices during Operation
• It cannot be used for the preservation of food, living creature, precise instrument and artworks, etc, otherwise damage
may occur.

• Use the fuse with proper capacity.


Metal wires and copper wires, etc., may cause fire or other faults.
• Do not use water heater or like next to the indoor unit and the wired controller. Water/power leakage or short circuit
may happen if the steam generating apparatus is working next to machine.

• Defrosting during heating


To improve the heating effect, the outdoor unit will perform defrosting automatically when frost appears on the outdoor
unit during heating (approximately 2-10 min).
During defrosting, the fan of the indoor unit runs at a low speed or stops while that of the outdoor unit stops running.
• Power should be cut off when the air conditioner is left unused for a long period.
Power will be consumed if the air conditioner is not powered off. The power switch of the outdoor unit switch should be
powered on 12 hours in advance before operation to protect the unit after a long period of storage.
• 3-minute protection
To protect the unit, compressor can be actuated with at least 3-minute delay after stopping.
• Close the window to avoid outdoor air getting in.
Curtains or window shutters can be put down to avoid the sunshine.

• Do not touch the switch with the wet hand to avoid power shock.

• Stop running and switch off the manual power switch when cleaning the unit.

• During the operation of the control unit, don't switch off the manual power switch and the controller can be used.
Please do not press the liquid crystal zone of controller to prevent damage
• Cleaning the unit with water may cause electric shock.

• Do not put flammable spray close to the air conditioner.


Don't inject flammable spray towards the air conditioner, which may cause fire.
• Stopping fan rotation
The unit which stops operating will actuate the fan for a 2-8 min swing every 30-60 minutes for protecting the unit while
other indoor unit are in the operating state.
• This appliance is not intended for use by persons (including children) with reducedphysical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.

4
Maintenance
• Only when the air cleaner is switched off and disconnected to the power supply can it be cleaned, or electric shock and
injury may appear.

Daily Maintenance:
Cleaning the air outlet port and the shell:
Attention
• Don't use gasoline, benzene, diluents, polishing powder or liquid insecticide to clean them.
• Do not clean them with hot water of above 50°C to avoid fading or distorting.

• Wipe them with soft dry cloth.


• Water or neutral dry cleanser is recommended if the dust cannot be removed.
• The Wind Deflector can be dismantled to clean (as below).

Cleaning Wind Deflector:


• Do not wipe the wind deflector with water forcibly to avoid falling off.

Cleaning Air Cleaner:


Attention
• Don't rinse the air cleaner with hot water of above 50°C to avoid fading and distorting.
• Don't put the air cleaner on the fire to dry to avoid catching fire.

• Pull the air screen forward to the front side of the unit to • Wipe dust with water or dust collector.
remove it. (A) Wipe dust with dust collector.
• Clean up air screens according to their different types.
For more information, please make contact with after
service staff.

(B) Clean it with soft bush in mild detergent if there is too


much dust on it.
(C) Throw off the water and airing it in the cool dry
condition.

Maintenance before and after Operating Season


Before Operating Season:
1. Please make the following checkup. If abnormal condition occurs, consult the after-service personnel.
• There is no blockage in inlet port and outlet port of outdoor and indoor units.
• The ground line and the wiring are in the proper state
2. After cleaning, the air cleaner must be mounted.
3. Switch on to the power.
After Operating Season:
1. In sunny days, blowing operation can be performed for half a day to make the inside of machine dry.
2. Electrical power should be cut down to economize electricity, or the machine will still consume power.Air cleaner
and shell must be mounted after cleaning.

5
Fault Checkup
Please check the following when consigning repair service:
Symptoms Reasons
Water flow sound can be heard when starting operation, during operation or
immediately after stopping operation. When it starts to work for 2-3 minutes,
Water flow sound
the sound may become louder, which is the flowing sound of refrigerant or
the draining sound of condensed water.
During operation, the air conditioner may make the cracking sound, which
Cracking sound is caused from the temperature changes or the slight dilation of heat
All these are not problems

exchanger.
The terrible smell, caused from walls, carpet, furniture, clothing, cigarette
Terrible smell in outlet air
and cosmetics, attaches on the conditioner.
When switching it on again after power failure, turn on the manual power
Flashing operating indicator
switch and the operating indicator flashes.
It displays the awaiting indication as it fails to perform refrigerating operation
while other indoor units are in heating operation. When the operator set it to
Awaiting indication
the refrigerating or heating mode and the operation is opposite to the setting,
it displays the awaiting indication.
To prevent oil and refrigerant from blocking the shutdown indoor units,
Sound in shutdown indoor unit or refrigerant flows in the short time and make the sounds of refrigerant flowing.
white steam or cold air Otherwise, when other indoor units performs heating operation, white steam
may occur; during refrigerating operation, cold air may appear.
Clicking sound when switching the When the conditioner is powered on, the sound is made due to the resetting
air condition on of the expansion valve.
Start or stop working automatically Check if it is in the state of Timer-ON and Timer-OFF.
Failure to work Check if there is a power failure.
Please make another check.

Check if the manual power switch is turned off.


Check if the supply fuse and breaker are disconnected.
Check if the protective unit is working.
Check if refrigerating and heating functions are selected simultaneously with
the awaiting indication on line control.
Check if air intake port and air outlet port of outdoor units are blocked.
Check if the door and windows are open.
Check if the filtering screen of air cleaner is blocked with sludge or dust.
Bad cooling & heating effects
Check if the setting of wind quantity is at low wind.
Check if the setting of operation is at the Fan Operation state.
Check if the temperature setting is proper.

Under the following circumstances, immediately stop the operation, disconnect the manual supply switch and contact the
after-service personnel.
• When buttons are inflexible actuated;
• When fuse and breaker have been burnt over and over;
• When there are foreign objects and water in the refrigerator;
• When it cannot still be operated after removing the operation of protective unit;
• When other abnormal conditions occur.

6
Installation Procedures
This manual does not cover all user cases; please contact Haier marketing centers in local places to propose new
requirements and clear new doubts and problems.

Standard installation tools are recommended according to installation requirements.


For information about standard model series accessories, see packing list; other necessary parts to be installed shall be
prepared by users as required by installation service network stations.

Decide upon places to install the indoor unit; places where even circulation of cool and warm
air can be delivered shall be selected; and places below shall be avoided:
Places (in coastal areas) where salinity is high; where sulfurized gases are usual (areas where springs flourish and copper
tube and braze easily get corroded); where oils (machinery oils) and steam are usual; where organic solvents are put to
use; where machines radiating high frequency electromagnetic waves exist (which cause control system malfunctions);
where contact with humid air near windows and doors is pervasive (making for easy condensation) and; where special
sprayers are put to frequent use.

Installing Indoor Unit


1. The distance from air outlet to floor surface shall not exceed 2.7m.
2. Make sure that outlet airflow covers the whole room area; and arrange connecting tubes, wires and drain pipes to
proper outdoor positions.
3. Make sure that ceiling structures are capable of bearing unit weight.
4. Connecting tubes, drain pipes and connecting wires can be put across walls to connect indoor unit and outdoor unit.
5. Connecting tubes and drain pipes between indoor and outdoor units shall be shorter for better.
6. Please refer to outdoor installation manual when refrigerant charging volume adjusting is necessary.
7. Joint flanges shall be prepared by users.
8. Valuables (e.g., TV sets, instruments, equipments, artworks, pianos, wireless devices) shall not be placed below the
indoor unit lest condensed water drips upon the same.

Installing and Fixing


1. Drilling Wall Holes
Drill a wall hole (dia.70mm, see figure 1), slightly tilted downwards on the outside; fix guard ring to finalize before
sealing the wall hole with gesso or putty.
Indoor Side Outdoor Side
Wall Hole
Wall Thickness
Ø70mm

Figure 1 (Wall Hole in Section)

2. Preparation prior to Installing Indoor Unit


(1) Open the intake grill
(2) Remove the Side cover(Right and left side)
(3) This air conditioner can be set up to intake fresh air. The information about how to install for fresh-air intake, refer to
"Fresh air intake".

Air filter

Intake grille Side cover A (Right side) Side cover A (Left side)

7
Installation Procedures
Open the intake grill
(1) Push the embeding switch according to the direction of the arrowhead.(Refer to Figure 2)
(2)Turn into the intake grill according to the direction of the arrowhead.(Refer to Figure 3)

Figure 3 Figure 2

Remove the Side cover


(1) Remove the screw.
(2) Push the Side cover according to the direction of the rrowhead.
(3) Then remove the Side cover.

Side cover

screw

Cut intake grill for drain pipe


(1) Tools:Knife or Pliers.
(2) Cut the intake grill before installing the drain pipe,Then,pass the drain pipe through the hole.As the following
schematic.

After removal

Location of the cut

8
Installation Procedures
3. Floor Type Installation
When the unit is installed on the floor,Installing CAUTION: drain pipe leading-out direction shown with figure below.
them as below:

Drain Pipe

Correct Wrong Wrong

Attention to distance from the unit to household usables or obstacles (as


shown with figure).
Connecting pipe

Floor
Left Right

Drain pipe

Over 30cm Over 30cm


4.Ceiling Installation

Left Right
Ceiling
a b
c
Model a b c
AC092~182MDERA Over 30cm Over 30cm Over 2cm
AC242~482MDERA Over 80cm Over 150cm Over 10cm
Ceiling Installation
(1) Use Ø10 hanger bolts, prepared on the site.
Please refer to figure on the right when installing.
When the unit is installed in the ceiling,side B is lower than side A for condensate discharge.As below.

10-15mm
10-15mm

A B A B

9
Installation Procedures
(2) Location of ceiling supension bolts

Model L
AC092MDERA
AC122MDERA
880
AC162MDERA
AC182MDERA
AC242MDERA
AC282MDERA 1204
AC302MDERA
AC382MDERA
1530
AC482MDERA

For half-concealed installation


Supension-bolt pitch should be as shown below

(3) Installing Hanger Bolt


Use M10 hanger bolt (prepared on the site) featuring 60mm hole depth, clearance fixed according to size proposed in the
air conditioner external view; install according to different building structure specifications to guard against safety faults;
and leveling instruments shall be available to ensure balanced installation.

(4) Please use hexagon bolts when installing

10
Installation Procedures
(5) Air Conditioner Installation Diagram

① Hanger Chain Hook ② Installing Status of Mounting Rack

Hanger Bolt Ceiling


(Ceiling)
≤40mm
Bolt Sleeve

Mounting Rack
M10 Unit (Wall)
Flat Spacer Hexagon Bolt
Double Nut

Leveling is forbidden after air conditioner is installed;


Hanger bolt is 40mm below ceiling. please make adjustment according to diagram indication.

③ Installing Air Conditioner ④ Drain Pipe Leading-out Direction

Mounting Rack

CAUTION:
Bolt
drain pipe shall be positioned high inside and low outside.
According to requirements on the site, drain pipes shall
be prepared by users on their own resources and make
sure that these are connected to drain pipes previously
available with the unit (make sure that measures are
Insert hexagon bolt into slot
taken to guard against water leakage in junction areas);
heat preservation shall be available with certain indoor
Screw tight hexagon bolt to fix air conditioner drain pipes through using heat insulant to prevent
condensation.

(6) Installing Deco Plate and Inlet Grille (after pipeline laying and electric wiring are done).

11
Installation Procedures
Attention
• For normal drainage, the water drainage piping should be connected according to the installation manual. Heat
insulation should be performed to avoid condensation. Improper pipe connection may cause water going into the
machine.

Requirements:
• Heat insulating treatment should be made for the water drainpipes of the indoor units.
• Heat preservation should be made for the connection with the indoor units. Improper heat preservation may cause
condensing.
• The drainpipe should be designed with a down gradient of 1/100. The midway of the elbow shouldn't be made in S
shape. Or abnormal noise may be caused.
• The lateral length of the drainpipe should be kept within 20m. Under the condition of long pipe, a support should be
provided every 1.52~2m to avoid unevenness.
• The central piping can be connected according the following figure.
• Don't apply external force to the connection of drainpipes.
1.5m~2m
support max. height (about 10cm)

heat S-shape elbow VP30


down gradient of over 1/100 down gradient
insulating
of over 1/100
material

Piping Materials & Heat Insulating Materials


As to prevent condensation, heat insulating treatment should be performed. The heat insulating treatment for piping
should be done respectively.
Piping Material Hard PVC tube VP31.5mm(inner bore)
Heat Insulating Material Vesicant polythene thickness: over 7mm

Hose
The drainage hose is made of Ø19.05mm (3/4") PVC tube, which can adjust the eccentricity and the angle of the hard
PVC tube.
• Stretch the hose directly to make connections as to avoid distortion. The soft end of the hose should be positioned with
a clamp.
• The hose should be used in the horizon direction. hose hose clamp

Heat Insulating Treatment:


• Wrap the connection between the clamp and the root
segment of the indoor unit without any gap with heat
insulating materials as shown in the drawing

heat insulating material


attached heat
insulating material
horniness pvc pipe

Confirming water drainage


During the test run, check the condition of water drainage and make sure that there is no leakage on the connection of
piping, which should also be performed during the winter.

12
Installation Procedures
Tubing Permissible Length & Height Difference
Please refer to the attached manual of outdoor units.

Tubing Permissible Length & Height Difference

Model AC092MDERA AC122~182MDERA AC242~482MDER


Gas pipe Ø9.52 Ø12.7 Ø15.88
Tubing Size (mm)
Liquid pipe Ø6.35 Ø6.35 Ø9.52
Tubing Material Phosphor deoxybronze seamless pipe (TP2) for air conditioner

Refrigerant Filling Amount


Add the refrigerant according to the installation instruction of outdoor unit. The addition of R410A refrigerant must be
performed with a measure gage to ensure the specified amount while compressor failure can be caused by filling too
much or little refrigerant.

Connecting Procedures of Refrigerant Tubing


Proceed the flare tube connecting operation to connect all the refrigerant tubes.
• Dual wrenches must be used in the connection of indoor unit tubing.
• Mounting torque refers to the right table
Outer Diameter of Tubing Mounting Torque Increase mounting Torque
(mm) (N-m) (N-m)
Ø6.35 11.8(1.2kgf-m) 13.7(1.4kgf-m)
wrench Ø9.52 24.5(2.5kgf-m) 29.4(3.0kgf-m)
Ø12.7 49.0(5.0kgf-m) 53.9(5.5kgf-m)
Ø15.88 78.4(8.0kgf-m) 98.0(10.0kgf-m)

Cutting and Enlarging Connecting


Cutting or enlarging pipes should be proceeded by 1. Connecting circular terminals:
installation personnel according to the operating The connecting method of circular terminal is shown in
criterion if the tube is too long or flare opening is the Fig. Take off the screw, connect it to the terminal tier
broken. after heading it through the ring Connecting
at the end of the lead and then circular
tighten it. terminals:
Vacuumizing 2.Connecting straight terminals:
Vacuumize from the stop valve of outdoor units with The connection methods for the circular terminals are
vacuum pump. Refrigerant sealed in indoor machine shown as follows: loosen the screw before putting the
is not allowed to use for vacuumization. line terminal into the terminal tier, tighten the screw and
confirm it has been clamped by pulling the line gently.
3.Pressing connecting line
Open All Valves After connecting line is completed, press the
Open all the valves of outdoor units. [NB: oil balancing connecting line with clips which should press on the
stop valve must be shut up completely when protective sleeve of the connecting line.
connected one main unit.]
terminal tier

Checkup for Air Leakage pressing clip


Check if there is any leakage at the connecting part correct wrong
and bonnet with hydrophone or soapsuds. pressing pressing

13
Electrical Wiring
WARNING
• Electrical construction should be made with specific mains circuit by the qualified personnel according to the installation
instruction. Electric shock and fire may be caused if the capacity of power supply is not sufficient.
• During arranging the wiring layout, specified cables should be used as the mains line, which accords with the local
regulations on wiring. Connecting and fastening should be performed reliably to avoid the external force of cables from
transmitting to the terminals. Improper connection or fastness may lead to burning or fire accidents.
• There must be the ground connection according to the criterion. Unreliable grounding may cause electrical shocks. Do
not connect the grounding line to the gas pipe, water pipe, lightening rod and telephone line.

Attention
• Only copper wire can be used. Breaker for electric leakage should be provided, or electric shock may occur.
• The wiring of the mains line is of Y type. The power plug L should be connected to the live wire and plug N connected
to null wire while should be connected to the ground wire. For the type with auxiliary electrically heating function, the
live wire and the null wire should not be misconnected, or the surface of electrical heating body will be electrified. If the
power line is damaged, replace it by the professional personnel of the manufacturer or service center.
• The power line of indoor units should be arranged according to the installation instruction of indoor units.
• The electrical wiring should be out of contact with the high-temperature sections of tubing as to avoid melting the
insulating layer of cables, which may cause accidents.
• After connected to the terminal tier, the tubing should be curved into be a U-type elbow and fastened with the pressing
clip.
• Controller wiring and refrigerant tubing can be arranged and fixed together.
• The machine can't be powered on before electrical operation. Maintenance should be done while the power is shut
down.
• Seal the thread hole with heat insulating materials to avoid condensation.
• Signal line and power line are separately independent, which can't share one line. [Note: the power line, signal line
are provided by users. Parameters for power lines are shown as below: 3×(1.0-1.5) mm2; parameters for signal line:
2×(0.75-1.25)mm2 (shielded line)]
• 5 butt lines (1.5mm) are equipped in the machine before delivery, which are used in connection between the valve box
and the electrical system of the machine. The detailed connection is displayed in the circuit diagram.

Supply Wiring Drawing

Outdoor 1 Outdoor 2 Outdoor 3

Ground Fault Interruptor Ground Fault Interruptor Ground Fault Interruptor


Circuit Breaker Circuit Breaker Circuit Breaker

Supply: 3N~,380-400V,50/60Hz Supply: 3N~,380-400V,50/60Hz Supply: 3N~,380-400V,50/60Hz

Indoor 1 Indoor 2 Indoor 3

Ground Fault Interruptor Ground Fault Interruptor Ground Fault Interruptor


Circuit Breaker Circuit Breaker Circuit Breaker

Supply: 1PH,220-230V~,50/60Hz Supply: 1PH,220-230V~,50/60Hz Supply: 1PH,220-230V~,50/60Hz


• Indoor units and outdoor units should be connected to the power source separately. Indoor units must share one single
electrical source, but its capacity and specifications should be calculated. Indoor & outdoor units should be equipped
with the power leakage breaker and the overflow breaker.
• Indoor and outdoor connection cable: H05RN-F 4G 2.5mm2 (Note: If the indoor and outdoor unit connection cable length
L satisfied condition 40m< L<55m, please change the connection cables specification to H07RN-F 4G 4.0mm2. If the
indoor and outdoor unit connection cable length L satisfied condition 55m≤L≤75m, please change the connection cables
specification to H07RN-F 4G 6.0mm2 )
14
Electrical Wiring
Signal Wiring Drawing

PQABC

(AC machine) (AC machine) (DC machine) (This machine)

PQABC PQABC PQABC PQABC PQABC

PQABC PQABC PQABC PQABC PQABC

PQABC PQABC PQABC PQABC PQABC

PQABC PQABC PQABC PQABC PQABC

Outdoor units are of parallel connection via three lines with polarity. The main unit, central control and all indoor units are
of parallel connection via two lines without polarity.
There are three connecting ways between line control and indoor units:
A.One line control controls multiple units, i.e. 2-16 indoor units, as shown in the above figure, (1-5 indoor units). The
indoor unit 5 is the line-controlled main unit(directly connected to the indoor unit of line control) and others are the ine-
controlled sub units. Among them, the 4 indoor unit is this unit, the 3 indoor unit is the other DC models, 1 indoor unit
and 2 indoor unit are the AC models.The line control device is connected with the line-controlled main unit and DC
models through three lines with polarity.Other indoor units and the main unit are connected via two lines with polarity.
SW01 on the main unit of line control is set to 0 while SW01 on other sub units of line control are set to 1, 2, 3 and so
on in turn. (Please refer to the code setting)
B. One line control controls one indoor unit, as shown in the above figure(indoor unit 6-19). The indoor unit and the line
control are connected via three lines with polarity.
C. Two line controls control one indoor unit, as shown in the figure (indoor unit 20). Either of the line controls can be set to
be the master line control while the other is set to be the auxiliary line control. The master line control and indoor units,
and the master and auxiliary line controls are connected via three lines with polarity.
When the indoor units are controlled by the remote control, switch over the modes by Switching Mode of Line-
Controlled Main Unit/ Line-Controlled Sub Units/ Remote-Controlled Types. The signal terminals needn't to be
equipped with wires and connected to the line control.
15
Electrical Wiring
The wiring for the power line of indoor unit, the wiring between indoor and outdoor units as well as the wiring between
indoor units:
Items Rated current of residual Cross Sectional
Rated Area of Signal Line
Cross Circuit Breaker(A)
Length Current of
Total Section Ground Fault
(m) Overflow Outdoor -indoor Indoor -indoor
Current of (mm2) Interruptor(mA)
Breaker(A) (mm2) (mm2)
Indoor Units(A) Response time(S)
<7 2.5 20 10 10 A,30 mA,0.1S or below
≥7 and <11 4 20 16 16 A,30 mA,0.1S or below
2 cores×0.75-2.0
≥11and <16 6 25 20 20 A,30 mA,0.1S or below
mm2 shielded line
≥16 and <22 8 30 32 32 A,30 mA,0.1S or below
≥22 and <27 10 40 32 32 A,30 mA,0.1S or below
• The electrical power line and signal lines must be fastened tightly.
• Every indoor unit must have the ground connection.
• The power line should be enlarged if it exceeds the permissible length.
• Shielded lays of all the indoor and outdoor units should be connected together, with the shielded lay at the side of signal
lines of outdoor units grounded at one point.
• It is not permissible if the whole length of signal line exceeds 1000m.

Signal Wiring of Wired controller


• The shielding lay of the signal line must be grounded at one
Length of Signal Line (m) Wiring Dimensions end.
≤250 0.75mm2 x core shielding line • The total length of the signal line shall not be more than 250m.

Dipswitch Setting
(A) Definition and description of SW01
[1] [2] [3] [4] Wired control address
0 0 0 0 Master unit in group control
SW01_1 0 0 0 1 Slave unit 1 in group control
SW01_2
Wired control address 0 0 1 0 Slave unit 2 in group control
SW01_3
SW01_4 0 0 1 1 Slave unit 3 in group control
∙∙∙ ∙∙∙ ∙∙∙ ∙∙∙ ∙∙∙
1 1 1 1 Slave unit 15 in group control
[5] [6] [7] [8] Indoor unit capacity
0 0 0 0 0.6HP
0 0 0 1 0.8HP
0 0 1 0 1.0HP
0 0 1 1 1.2HP
0 1 0 0 1.5HP
0 1 0 1 1.7HP
SW01_5 0 1 1 0 2.0HP
SW01_6
Indoor unit capacity 0 1 1 1 2.5HP
SW01_7
SW01_8 1 0 0 0 3.0HP
1 0 0 1 3.2HP
1 0 1 0 4.0HP
1 0 1 1 5.0HP
1 1 0 0 6.0HP
1 1 0 1 8.0HP
1 1 1 0 10.0HP
1 1 1 1 15.0HP
16
Electrical Wiring
(B) Definition and description of SW03
Manner of set 0 Set the address with wired controller or automatism (default)
SW03_1
address 1 Set the address with dip switch
Address of centralized
[2] [3] [4] [5] [6] [7] [8] Address of indoor unit
controller
0 0 0 0 0 0 0 0# (Default) 0# (Default)
0 0 0 0 0 0 1 1# 1#
Set the
Communication 0 0 0 0 0 1 0 2# 2#
SW03_2 … … … … … … … … …
and Central
~
control address 0 1 1 1 1 1 1 63# 63#
SW03_8
with dip switch 1 0 0 0 0 0 0 0# 64#
(*Note) 1 0 0 0 0 0 1 1# 65#
1 0 0 0 0 1 0 2# 66#
… … … … … … … … …
1 1 1 1 1 1 1 63# 127#
Note *:
• Set the address by code when connecting the centralized controller or gateway or charge system.
• Address of centralized controller=communication address+0 or+64.
SW03_ 2=OFF, address of centralized controller=communication address+0=communication address
SW03_ 2=ON, address of centralized controller=communication address+64 (applies when centralized controller is
used and there are more than 64 indoor units)
• To use with 0010451181A in use, it is required to use code for address setting. Set SW03_1=0N
and SW03_ 2=OFF; SW03_3, SW03_ 4, SW03_5, SW03_6, SW03_7 and SW03_ 8 are address codes which are set
according to actual address.
• Address setting function of wired controller for ultrathin card machine is disnabled.

17
Test Run & Fault Code
Before Test Run
• Before switching it on, test the supply terminal tier (L, N terminals) and grounding points with 500V megaohm meter and
check if the resistance is above 1MΩ. It can't be operated if it is below 1MΩ.
• Connect it to the power supply of outdoor units to energize the heating belt of the compressor. To protect the
compressor at startup, power it on 12 hours prior to the operation.
Check if the arrangements of the drainpipe and connection line are correct.
The drainpipe shall be placed at the lower part while the connection line placed at the upper part. Heat preservation
measures should be taken such as winding the drainpipe esp. in the indoor units with heating insulating materials.
The drain pipe should be made a slope type to avoid protruding at the upper part and concaving at the lower part on the
way.

Checkup of Installation
check if the mains voltage is matching check if the installation place meets the requirement
check if there is air leakage at the piping joints check if there is too much noise
check if the connections of mains power and indoor & outdoor check if the connecting line is fastened
units are correct check if the connectors for tubing are heat insulated
check if the serial numbers of terminals are matching check if the water is drained to the outside
check if the indoor units are positioned

Ways of Test Run


Do ask the installation personnel to make a test run. Take the testing procedures according to the manual and check if the
temperature regulator works properly.
When the machine fails to start due to the room temperature, the following procedures can be taken to do the compulsive
running. The function is not provided for the type with remote control.
• Set the wired controller (E17) to cooling/heating mode, press "ON/OFF" button for 10 seconds to enter into the
compulsive cooling/heating mode. Repress "ON/OFF" button to quit the compulsive running and stop the operation of
the air conditioner.

Fault Remedies
When any fault appears, consult the fault code of line control or the flashing times for LED5 of computer panel of indoor
units/health lamp of receiving window of remote control and find out the faults as shown in the following table to remove
all faults.
Indoor Unit Faults
Failure code at PCB LED5 (Indoor Units) / Receiver
Fault Descriptions
wired controller Timer Lamp (RemoteController)
1 1 Fault of indoor unit ambient temp. transducer TA
2 2 Fault of indoor unit pipe temp. transducer TC1
3 3 Fault of indoor unit pipe temp. transducer TC2
5 5 Fault of indoor unit EEPROM
6 6 Fault of communication between indoor & outdoor units
7 7 Fault of communication between indoor unit and wired control
8 8 Fault of indoor unit water drainage
9 9 Fault of duplicate indoor unit address
14 14 Fault of DC MOTOR
18 18 Fault of BS valve box or 4MV Reverse
20 20 Corresponding faults of outdoor units

18
Move and scrap the air conditioning
• When moving, to disassemble and re-install the air conditioning, please contact your dealer for technical support.
• In the composition material of air conditioning, the content of lead, mercury, hexavalent chromium, polybrominated
biphenyls and polybrominated diphenyl ethers are not more than 0.1% (mass fraction) and cadmium is not more than
0.01% (mass fraction).
• Please recycle the refrigerant before scrapping, moving, setting and repairing the air conditioning; for the air conditioning
scrapping, should be dealt with by the qualified enterprises.

19