No. 0150538640
• The indoor unit, suspended to ceiling or standing on floor, renders considerable operating ease and flexibility.
• With its ultra-thin design, dazzling exterior and space economy, the indoor unit fits in well with indoor scenarios.
• Boasting superb power and fast temperature tuning, the indoor unit delivers undeniable comforts and pleasures
whenever you feel like wanting the same.
• Highly efficient silencing technology greatly reduces operating noises and delivers natural comforts.
• In case of sudden blackout during operation, the indoor unit, with its Blackout Retrieval function preset, is capable of
retrieving its operating status prior to the blackout when power supply is restored.
• Integrated Control is available with the indoor unit (through integrated controller).
• Multi-connected unit series features "uniform control mode", i.e., all indoor units are restricted to run on heating or
cooling mode at the same time.
• For the protection of compressor, the air conditioning unit shall be powered for over 12 hours.
Warning
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons
in order to avoid a hazard.
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
• Children should be supervised to ensure that they do not play with the appliance.
• This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.
• The appliances are not intended to be operated by means of an external timer or separate remote-control system.
• Keep the appliance and its cord out of reach of children less than 8 years.
Wi-Fi
Indicator
Human Sensor Lamp
Note:
For the wired control type unit, the unit state should be checked by the wired controller, instead of the
remote receiver. And if you set the TIMER function, the TIMER LED on the remote receiver will not be on.
2
HEAT: 3
5 4 3 2 1
4
5
1 Air Guide Plate Positioning Swing Range
2 ① ①→③
3 ② ①→③
③ ②→④
4
④ ③→⑤
5 ①→⑤
⑤
(All Covered)
1
Safety
• If the air conditioner is transferred to a new user, this manual shall be transferred to the user, together with the
conditioner.
• Before installation, be sure to read Safety Considerations in this manual for proper installation.
• The safety considerations stated below is divided into " WARNING" and " CAUTION". The matters on severe
accidents caused from wrong installation, which is likely to lead to death or serious injury, are listed in " WARNING".
However, the matters listed in " CAUTION" are also likely cause the severe accidents. In general, both of them are
the important items related to the security, which should be strictly abided by.
• After the installation, perform test run to make sure everything is in normal conditions, and then operate and maintain
the air conditioner in accordance with the User Manual. The User Manual should be delivered to the user for proper
keeping.
WARNING
• Please ask the special maintenance station for installation and repair. Water leakage, electric shocks or fire accidents
might be caused from improper installation if you conduct the installation by your own.
• The installation should be conducted properly according to this manual. Water leakage, electric shocks or fire accidents
might be caused from improper installation.
• Please make sure to install the air conditioner on the place where can bear the weight of the air conditioner. The air
conditioner can't be installed on the grids such as the non-special metal burglar-proof net. The place with insufficient
support strength might cause the dropdown of the machine, which may lead to personal injuries.
• The installation should be ensured against typhoons and earthquakes, etc. The installation unconformable to the
requirements will lead to accidents due to the turnover of the machine.
• Specific cables should be used for reliable connections of the wirings. Please fix the terminal connections reliably to
avoid the outside force applied on the cables from being impressed on the cables. Improper connections and fixings
might lead to such accidents as heating or fire accidents.
• Correct shapes of wirings should be kept while the embossed shape is not allowed. The wirings should be reliably
connected to avoid the cover and the plate of the electrical cabinet lipping the wiring. Improper installation might cause
such accidents as heating or fire accidents.
• While placing or reinstalling the air conditioner, except the specific refrigerant (R410A), don't let the air go into the
refrigeration cycle system. The air in the refrigeration cycle system might lead to the cracking or personal injuries due to
abnormal high pressure of the refrigeration cycle system.
• During installation, please use the accompanied spare parts or specific parts. If not, water leakage, electric shocks, fire
accidents or refrigerant leakage might be caused.
• Don't drain the water from the drainpipe to the waterspout where may exist harmful gases such as sulfureted gas to
avoid the harmful gases entering into the room.
• During installation, if refrigerant leakage occurs, ventilation measures should be taken, for the refrigerant gas might
generate harmful gases upon contacting the flame.
• After installation, check if any refrigerant leakage exists. If the refrigerant gas leaks in the room, such things as air
blowing heaters and stoves, etc. may generate harmful gases.
• Don't install the air conditioner at the places where the flammable gases may leak. In case the gas leakage occurs
around the machine, such accidents as fire disasters may be caused.
• The drainpipe should be properly mounted according to this manual as to ensure the smooth drainage. In addition, heat
preservation should be taken to avoid condensation. Improper drainpipe mounting might cause water leakage, which
will get the articles at home wet.
• The refrigerant gas pipe and liquid pipe should be heat insulated to preserve heat. For inappropriate heat insulation, the
water caused from the condensation will drop to get the article at home wet.
CAUTION
• The air conditioner should be effectively grounded. Electric shocks may occur if the air conditioner is ungrounded or
inappropriately grounded. The wire for earthing shouldn't be connected to the connections on the gas pipe, water pipe,
lightning rod or telephone.
• The breaker for electricity leakage should be mounted. If not, accidents such as electric shocks may happen.
• The installed air conditioner should be checked for electricity leakage by being powered.
• If the ambient humidity bigger than 80%, when the water discharge hole be blocked or the filter becomes dirty, or airflow
speed change, there maybe leads to condensing water drop down, and at the same time there maybe some drops of
water spit out.
2
Safety
Items with this warning sign concerning the product's safety and the personal security must be performed
strictly.
Items with this forbidding sign refer to absolutely forbidden behaviors. If not, they may cause machine damage
or endanger operator's personal safety.
Clean the filter regularly. Don't touch the outlet while the flap is moving. Don't put
Cooling or heating performance will be degraded if the filter anything in the grid in case danger may occur.
is blocked, resulting in large power consumption, failure,
and water dripping at freezing.
• Flammable apparatus should not be placed in the place where the air conditioner wind could reach directly, or
incomplete burning of the apparatus may be caused.
• Check the mount table of the air conditioner for damage for a long period of operation.
If placed on the damaged table, the unit may drop down causing damage.
• Plants and animals should not be put to the place where wind of the air conditioner blows directly, otherwise damage
to them may be caused.
3
Safety
Notices during Operation
• It cannot be used for the preservation of food, living creature, precise instrument and artworks, etc, otherwise damage
may occur.
• Do not touch the switch with the wet hand to avoid power shock.
• Stop running and switch off the manual power switch when cleaning the unit.
• During the operation of the control unit, don't switch off the manual power switch and the controller can be used.
Please do not press the liquid crystal zone of controller to prevent damage
• Cleaning the unit with water may cause electric shock.
4
Maintenance
• Only when the air cleaner is switched off and disconnected to the power supply can it be cleaned, or electric shock and
injury may appear.
Daily Maintenance:
Cleaning the air outlet port and the shell:
Attention
• Don't use gasoline, benzene, diluents, polishing powder or liquid insecticide to clean them.
• Do not clean them with hot water of above 50°C to avoid fading or distorting.
• Pull the air screen forward to the front side of the unit to • Wipe dust with water or dust collector.
remove it. (A) Wipe dust with dust collector.
• Clean up air screens according to their different types.
For more information, please make contact with after
service staff.
5
Fault Checkup
Please check the following when consigning repair service:
Symptoms Reasons
Water flow sound can be heard when starting operation, during operation or
immediately after stopping operation. When it starts to work for 2-3 minutes,
Water flow sound
the sound may become louder, which is the flowing sound of refrigerant or
the draining sound of condensed water.
During operation, the air conditioner may make the cracking sound, which
Cracking sound is caused from the temperature changes or the slight dilation of heat
All these are not problems
exchanger.
The terrible smell, caused from walls, carpet, furniture, clothing, cigarette
Terrible smell in outlet air
and cosmetics, attaches on the conditioner.
When switching it on again after power failure, turn on the manual power
Flashing operating indicator
switch and the operating indicator flashes.
It displays the awaiting indication as it fails to perform refrigerating operation
while other indoor units are in heating operation. When the operator set it to
Awaiting indication
the refrigerating or heating mode and the operation is opposite to the setting,
it displays the awaiting indication.
To prevent oil and refrigerant from blocking the shutdown indoor units,
Sound in shutdown indoor unit or refrigerant flows in the short time and make the sounds of refrigerant flowing.
white steam or cold air Otherwise, when other indoor units performs heating operation, white steam
may occur; during refrigerating operation, cold air may appear.
Clicking sound when switching the When the conditioner is powered on, the sound is made due to the resetting
air condition on of the expansion valve.
Start or stop working automatically Check if it is in the state of Timer-ON and Timer-OFF.
Failure to work Check if there is a power failure.
Please make another check.
Under the following circumstances, immediately stop the operation, disconnect the manual supply switch and contact the
after-service personnel.
• When buttons are inflexible actuated;
• When fuse and breaker have been burnt over and over;
• When there are foreign objects and water in the refrigerator;
• When it cannot still be operated after removing the operation of protective unit;
• When other abnormal conditions occur.
6
Installation Procedures
This manual does not cover all user cases; please contact Haier marketing centers in local places to propose new
requirements and clear new doubts and problems.
Decide upon places to install the indoor unit; places where even circulation of cool and warm
air can be delivered shall be selected; and places below shall be avoided:
Places (in coastal areas) where salinity is high; where sulfurized gases are usual (areas where springs flourish and copper
tube and braze easily get corroded); where oils (machinery oils) and steam are usual; where organic solvents are put to
use; where machines radiating high frequency electromagnetic waves exist (which cause control system malfunctions);
where contact with humid air near windows and doors is pervasive (making for easy condensation) and; where special
sprayers are put to frequent use.
Air filter
Intake grille Side cover A (Right side) Side cover A (Left side)
7
Installation Procedures
Open the intake grill
(1) Push the embeding switch according to the direction of the arrowhead.(Refer to Figure 2)
(2)Turn into the intake grill according to the direction of the arrowhead.(Refer to Figure 3)
Figure 3 Figure 2
Side cover
screw
After removal
8
Installation Procedures
3. Floor Type Installation
When the unit is installed on the floor,Installing CAUTION: drain pipe leading-out direction shown with figure below.
them as below:
Drain Pipe
Floor
Left Right
Drain pipe
Left Right
Ceiling
a b
c
Model a b c
AC092~182MDERA Over 30cm Over 30cm Over 2cm
AC242~482MDERA Over 80cm Over 150cm Over 10cm
Ceiling Installation
(1) Use Ø10 hanger bolts, prepared on the site.
Please refer to figure on the right when installing.
When the unit is installed in the ceiling,side B is lower than side A for condensate discharge.As below.
10-15mm
10-15mm
A B A B
9
Installation Procedures
(2) Location of ceiling supension bolts
Model L
AC092MDERA
AC122MDERA
880
AC162MDERA
AC182MDERA
AC242MDERA
AC282MDERA 1204
AC302MDERA
AC382MDERA
1530
AC482MDERA
10
Installation Procedures
(5) Air Conditioner Installation Diagram
Mounting Rack
M10 Unit (Wall)
Flat Spacer Hexagon Bolt
Double Nut
Mounting Rack
CAUTION:
Bolt
drain pipe shall be positioned high inside and low outside.
According to requirements on the site, drain pipes shall
be prepared by users on their own resources and make
sure that these are connected to drain pipes previously
available with the unit (make sure that measures are
Insert hexagon bolt into slot
taken to guard against water leakage in junction areas);
heat preservation shall be available with certain indoor
Screw tight hexagon bolt to fix air conditioner drain pipes through using heat insulant to prevent
condensation.
(6) Installing Deco Plate and Inlet Grille (after pipeline laying and electric wiring are done).
11
Installation Procedures
Attention
• For normal drainage, the water drainage piping should be connected according to the installation manual. Heat
insulation should be performed to avoid condensation. Improper pipe connection may cause water going into the
machine.
Requirements:
• Heat insulating treatment should be made for the water drainpipes of the indoor units.
• Heat preservation should be made for the connection with the indoor units. Improper heat preservation may cause
condensing.
• The drainpipe should be designed with a down gradient of 1/100. The midway of the elbow shouldn't be made in S
shape. Or abnormal noise may be caused.
• The lateral length of the drainpipe should be kept within 20m. Under the condition of long pipe, a support should be
provided every 1.52~2m to avoid unevenness.
• The central piping can be connected according the following figure.
• Don't apply external force to the connection of drainpipes.
1.5m~2m
support max. height (about 10cm)
Hose
The drainage hose is made of Ø19.05mm (3/4") PVC tube, which can adjust the eccentricity and the angle of the hard
PVC tube.
• Stretch the hose directly to make connections as to avoid distortion. The soft end of the hose should be positioned with
a clamp.
• The hose should be used in the horizon direction. hose hose clamp
12
Installation Procedures
Tubing Permissible Length & Height Difference
Please refer to the attached manual of outdoor units.
13
Electrical Wiring
WARNING
• Electrical construction should be made with specific mains circuit by the qualified personnel according to the installation
instruction. Electric shock and fire may be caused if the capacity of power supply is not sufficient.
• During arranging the wiring layout, specified cables should be used as the mains line, which accords with the local
regulations on wiring. Connecting and fastening should be performed reliably to avoid the external force of cables from
transmitting to the terminals. Improper connection or fastness may lead to burning or fire accidents.
• There must be the ground connection according to the criterion. Unreliable grounding may cause electrical shocks. Do
not connect the grounding line to the gas pipe, water pipe, lightening rod and telephone line.
Attention
• Only copper wire can be used. Breaker for electric leakage should be provided, or electric shock may occur.
• The wiring of the mains line is of Y type. The power plug L should be connected to the live wire and plug N connected
to null wire while should be connected to the ground wire. For the type with auxiliary electrically heating function, the
live wire and the null wire should not be misconnected, or the surface of electrical heating body will be electrified. If the
power line is damaged, replace it by the professional personnel of the manufacturer or service center.
• The power line of indoor units should be arranged according to the installation instruction of indoor units.
• The electrical wiring should be out of contact with the high-temperature sections of tubing as to avoid melting the
insulating layer of cables, which may cause accidents.
• After connected to the terminal tier, the tubing should be curved into be a U-type elbow and fastened with the pressing
clip.
• Controller wiring and refrigerant tubing can be arranged and fixed together.
• The machine can't be powered on before electrical operation. Maintenance should be done while the power is shut
down.
• Seal the thread hole with heat insulating materials to avoid condensation.
• Signal line and power line are separately independent, which can't share one line. [Note: the power line, signal line
are provided by users. Parameters for power lines are shown as below: 3×(1.0-1.5) mm2; parameters for signal line:
2×(0.75-1.25)mm2 (shielded line)]
• 5 butt lines (1.5mm) are equipped in the machine before delivery, which are used in connection between the valve box
and the electrical system of the machine. The detailed connection is displayed in the circuit diagram.
PQABC
Outdoor units are of parallel connection via three lines with polarity. The main unit, central control and all indoor units are
of parallel connection via two lines without polarity.
There are three connecting ways between line control and indoor units:
A.One line control controls multiple units, i.e. 2-16 indoor units, as shown in the above figure, (1-5 indoor units). The
indoor unit 5 is the line-controlled main unit(directly connected to the indoor unit of line control) and others are the ine-
controlled sub units. Among them, the 4 indoor unit is this unit, the 3 indoor unit is the other DC models, 1 indoor unit
and 2 indoor unit are the AC models.The line control device is connected with the line-controlled main unit and DC
models through three lines with polarity.Other indoor units and the main unit are connected via two lines with polarity.
SW01 on the main unit of line control is set to 0 while SW01 on other sub units of line control are set to 1, 2, 3 and so
on in turn. (Please refer to the code setting)
B. One line control controls one indoor unit, as shown in the above figure(indoor unit 6-19). The indoor unit and the line
control are connected via three lines with polarity.
C. Two line controls control one indoor unit, as shown in the figure (indoor unit 20). Either of the line controls can be set to
be the master line control while the other is set to be the auxiliary line control. The master line control and indoor units,
and the master and auxiliary line controls are connected via three lines with polarity.
When the indoor units are controlled by the remote control, switch over the modes by Switching Mode of Line-
Controlled Main Unit/ Line-Controlled Sub Units/ Remote-Controlled Types. The signal terminals needn't to be
equipped with wires and connected to the line control.
15
Electrical Wiring
The wiring for the power line of indoor unit, the wiring between indoor and outdoor units as well as the wiring between
indoor units:
Items Rated current of residual Cross Sectional
Rated Area of Signal Line
Cross Circuit Breaker(A)
Length Current of
Total Section Ground Fault
(m) Overflow Outdoor -indoor Indoor -indoor
Current of (mm2) Interruptor(mA)
Breaker(A) (mm2) (mm2)
Indoor Units(A) Response time(S)
<7 2.5 20 10 10 A,30 mA,0.1S or below
≥7 and <11 4 20 16 16 A,30 mA,0.1S or below
2 cores×0.75-2.0
≥11and <16 6 25 20 20 A,30 mA,0.1S or below
mm2 shielded line
≥16 and <22 8 30 32 32 A,30 mA,0.1S or below
≥22 and <27 10 40 32 32 A,30 mA,0.1S or below
• The electrical power line and signal lines must be fastened tightly.
• Every indoor unit must have the ground connection.
• The power line should be enlarged if it exceeds the permissible length.
• Shielded lays of all the indoor and outdoor units should be connected together, with the shielded lay at the side of signal
lines of outdoor units grounded at one point.
• It is not permissible if the whole length of signal line exceeds 1000m.
Dipswitch Setting
(A) Definition and description of SW01
[1] [2] [3] [4] Wired control address
0 0 0 0 Master unit in group control
SW01_1 0 0 0 1 Slave unit 1 in group control
SW01_2
Wired control address 0 0 1 0 Slave unit 2 in group control
SW01_3
SW01_4 0 0 1 1 Slave unit 3 in group control
∙∙∙ ∙∙∙ ∙∙∙ ∙∙∙ ∙∙∙
1 1 1 1 Slave unit 15 in group control
[5] [6] [7] [8] Indoor unit capacity
0 0 0 0 0.6HP
0 0 0 1 0.8HP
0 0 1 0 1.0HP
0 0 1 1 1.2HP
0 1 0 0 1.5HP
0 1 0 1 1.7HP
SW01_5 0 1 1 0 2.0HP
SW01_6
Indoor unit capacity 0 1 1 1 2.5HP
SW01_7
SW01_8 1 0 0 0 3.0HP
1 0 0 1 3.2HP
1 0 1 0 4.0HP
1 0 1 1 5.0HP
1 1 0 0 6.0HP
1 1 0 1 8.0HP
1 1 1 0 10.0HP
1 1 1 1 15.0HP
16
Electrical Wiring
(B) Definition and description of SW03
Manner of set 0 Set the address with wired controller or automatism (default)
SW03_1
address 1 Set the address with dip switch
Address of centralized
[2] [3] [4] [5] [6] [7] [8] Address of indoor unit
controller
0 0 0 0 0 0 0 0# (Default) 0# (Default)
0 0 0 0 0 0 1 1# 1#
Set the
Communication 0 0 0 0 0 1 0 2# 2#
SW03_2 … … … … … … … … …
and Central
~
control address 0 1 1 1 1 1 1 63# 63#
SW03_8
with dip switch 1 0 0 0 0 0 0 0# 64#
(*Note) 1 0 0 0 0 0 1 1# 65#
1 0 0 0 0 1 0 2# 66#
… … … … … … … … …
1 1 1 1 1 1 1 63# 127#
Note *:
• Set the address by code when connecting the centralized controller or gateway or charge system.
• Address of centralized controller=communication address+0 or+64.
SW03_ 2=OFF, address of centralized controller=communication address+0=communication address
SW03_ 2=ON, address of centralized controller=communication address+64 (applies when centralized controller is
used and there are more than 64 indoor units)
• To use with 0010451181A in use, it is required to use code for address setting. Set SW03_1=0N
and SW03_ 2=OFF; SW03_3, SW03_ 4, SW03_5, SW03_6, SW03_7 and SW03_ 8 are address codes which are set
according to actual address.
• Address setting function of wired controller for ultrathin card machine is disnabled.
17
Test Run & Fault Code
Before Test Run
• Before switching it on, test the supply terminal tier (L, N terminals) and grounding points with 500V megaohm meter and
check if the resistance is above 1MΩ. It can't be operated if it is below 1MΩ.
• Connect it to the power supply of outdoor units to energize the heating belt of the compressor. To protect the
compressor at startup, power it on 12 hours prior to the operation.
Check if the arrangements of the drainpipe and connection line are correct.
The drainpipe shall be placed at the lower part while the connection line placed at the upper part. Heat preservation
measures should be taken such as winding the drainpipe esp. in the indoor units with heating insulating materials.
The drain pipe should be made a slope type to avoid protruding at the upper part and concaving at the lower part on the
way.
Checkup of Installation
check if the mains voltage is matching check if the installation place meets the requirement
check if there is air leakage at the piping joints check if there is too much noise
check if the connections of mains power and indoor & outdoor check if the connecting line is fastened
units are correct check if the connectors for tubing are heat insulated
check if the serial numbers of terminals are matching check if the water is drained to the outside
check if the indoor units are positioned
Fault Remedies
When any fault appears, consult the fault code of line control or the flashing times for LED5 of computer panel of indoor
units/health lamp of receiving window of remote control and find out the faults as shown in the following table to remove
all faults.
Indoor Unit Faults
Failure code at PCB LED5 (Indoor Units) / Receiver
Fault Descriptions
wired controller Timer Lamp (RemoteController)
1 1 Fault of indoor unit ambient temp. transducer TA
2 2 Fault of indoor unit pipe temp. transducer TC1
3 3 Fault of indoor unit pipe temp. transducer TC2
5 5 Fault of indoor unit EEPROM
6 6 Fault of communication between indoor & outdoor units
7 7 Fault of communication between indoor unit and wired control
8 8 Fault of indoor unit water drainage
9 9 Fault of duplicate indoor unit address
14 14 Fault of DC MOTOR
18 18 Fault of BS valve box or 4MV Reverse
20 20 Corresponding faults of outdoor units
18
Move and scrap the air conditioning
• When moving, to disassemble and re-install the air conditioning, please contact your dealer for technical support.
• In the composition material of air conditioning, the content of lead, mercury, hexavalent chromium, polybrominated
biphenyls and polybrominated diphenyl ethers are not more than 0.1% (mass fraction) and cadmium is not more than
0.01% (mass fraction).
• Please recycle the refrigerant before scrapping, moving, setting and repairing the air conditioning; for the air conditioning
scrapping, should be dealt with by the qualified enterprises.
19