0% found this document useful (0 votes)
489 views1 page

Residential Electrical Plan & Specs

1. The electric service specifications include overhead 230V 1-phase 2-wire 60Hz service. 2. The main disconnect switch shall be 50A 415V 20kAIC 2P thermal-magnetic field molded case circuit breaker. 3. The service entrance conductor shall be 2- 30 mm2 THHN copper wire.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
489 views1 page

Residential Electrical Plan & Specs

1. The electric service specifications include overhead 230V 1-phase 2-wire 60Hz service. 2. The main disconnect switch shall be 50A 415V 20kAIC 2P thermal-magnetic field molded case circuit breaker. 3. The service entrance conductor shall be 2- 30 mm2 THHN copper wire.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

SPECIFICATIONS 13 13

4 4.5 4.5 4 4.5 4.5


1. ELECTRIC SERVICE SHALL BE OVERHEAD, 230 V, 1- PHASE, 2- WIRE, 60 CYCLES
PER SECOND.
2 FIRE EXIT 2.5 2 FIRE EXIT 2.5
C2 SIJ

2. MAIN DISCONNECT SWITCH SHALL BE 50 AT, 415 V, 20 KAIC, 2P PB


THERMAL -MAGNETIC FIELD MOLDED CASE CIRCUIT BREAKER. LAUNDRY C5
w
C7
PB LAUNDRY w
PB
AREA KITCHEN BEDROOM 2 AREA KITCHEN BEDROOM 2
3. SERVICE ENTRANCE CONDUCTOR SHALL BE 2- 30 mm² THHN COPPER WIRE. D D
I
C4 L
4. TYPE OF WIRING SHALL BE CONCEALED ON WALLS AND CEILING FOR LIGHTING PB
AND POWER LOADS. 4.5 4.5
H
5. INSTALLATION HEIGHT SHALL BE AS FOLLOWS: J
A. LIGHTING SWITCHES 1.4 m ABOVE FINISHED FLOOR LINE
B. CONVENIENCE & AUXILIARY OUTLETS 0.3 m ABOVE FINISHED FLOOR LINE 6.5 DINING 6.5 DINING
C. PANEL BOARDS (@ THE CENTER) 1.7 m ABOVE FINISHED FLOOR LINE AREA AREA
GARAGE GARAGE
6. SWITCHES AND CONVENIENCE SHALL BE RATED 10 AND 15 AMPERES SH

RESPECTIVELY, 240 V, FLUSH TYPE.


T&B C6
PB
T&B
7. ALL MATERIALS AND EQUIPMENT TO BE USED SHALL BE BRAND NEW AND K
APPROVED FOR THAT PURPOSE. 2 11 SF

F
2 11
G
8. ALL ELECTRICAL CONDUCTORS TO BE USED SHALL BE STRANDED COPPER AS
SKL

MANUFACTURED BY ANY APPROVED BRAND. SG

SE

C1
9. EFFECTIVE GROUNDING SYSTEM SHOULD BE PROVIDED IN ACCORDANCE WITH
1.35 2 LIVING AREA PB
1.35 2 LIVING AREA
THE PROVISION OF THE PHILIPPINE ELECTRIC CODE.

PORCH
PORCH SCD
BEDROOM 1
BEDROOM 1 A SAB

10. BRANCH CIRCUIT PROTECTION, CONDUCTORS, CIRCUIT PIPE, ETC. SHALL BE


BASED ON THE SCHEDULE OF LOADS AND SINGLE LINE DIAGRAM. C
11. BRANCH CIRCUIT HOMERUNS SHALL NOT BE COMBINED IN THE SAME 4.5 MAIN 4.5 4.5 MAIN
D E
4.5
RACEWAY AND RACEWAY FOR AUXILIARY LINES SHALL NOT CONTAIN POWER ENTRANCE ENTRANCE
LINES. C3
PB

1.35 2 1.35 2
12. ALL ELECTRICAL INSTALLATION SHALL BE DONE UNDER THE DIRECT B
SUPERVISION OF A DULY LICENSED ELECTRICAL ENGINEER OR MASTER PB PB
ELETRICIAN.
0.0000 0.0000

13. ALL WORKS SHALL BE DONE IN ACCORDANCE WITH THE LATEST EDITION OF
THE PHILIPPINE ELECTRICAL CODE (PEC), THE RULES AND REGULATIONS OF
LOCAL AND NATIONAL AUTHORITIES CONCERNED WITH ENFORCEMENT OF RULES 2 6.5 4.5 2 6.5 4.5
AND REGULATIONS OF LOCAL UTILITY COMPANY.

POWER LAY-OUT LIGHTING LAY-OUT


SCALE 14.85: 1M SCALE 14.85:1M

LEGEND:
2 - 30 mm2 THHN ILECO
SYMBOL DESCRIPTION CU. WIRE INCOMING

M
20 W LED BULB SCHEDULE OF LOADS AND DESIGN ANALYSIS KWH METER
PANEL NAME: PB
DUPLEX CONVENIENCE OUTLET ENCLOSURE: NEMA 1, FLUSH MOUNTED, THERMOPLASTIC 230 V, 1-PHASE, 60Hz, 2-WIRE SERVICE
LOCATION: NEAR LIVING AREA PB
PB
PANEL BOARD OUTLET SWITCHES OVER CURRENT PROTECTION CONDUIT TYPE
CKT AMPERE CONDUCTOR SIZE AND TYPE + EQUIPMENT GROUNDING
LOAD DESCRIPTION VA C1
NO L.O C.O OTHERS S1 S2 S3 S3W LOAD CONDUCTOR AT V P KAIC TYPE SIZE TYPE 50AT, 2P 20AT, 2P

C2 1 2-3.5 mm2 THHN-2 CU. WIRE + 1-3.5 mm2 TW CU. WIRE (PE)
PB CIRCUIT HOMERUN 6 - 180 VA DUPLEX CONVENIENCE OUTLET 6 1080 4.70 20 240 2 10 BOLT-ON 20 mmØ uPVC
C2 C3
2 2 20AT, 2P 20AT, 2P
2 5 - 180 VA DUPLEX CONVENIENCE OUTLET 5 900 3.91 2-3.5 mm THHN-2 CU. WIRE + 1-3.5 mm TW CU. WIRE (PE) 20 240 2 10 BOLT-ON 20 mmØ uPVC

S ONE GANG SWITCH 3 5 - 180 VA DUPLEX CONVENIENCE OUTLET 5 900 3.91 2-3.5 mm2 THHN-2 CU. WIRE + 1-3.5 mm2 TW CU. WIRE (PE) 20 240 2 10 BOLT-ON 20 mmØ uPVC
C4 C5
4 1-1 HP, 0.65 PF, REFRIGERATOR 1 1196 4.35 2-3.5 mm2 THHN-2 CU. WIRE + 1-3.5 mm2 TW CU. WIRE (PE) 20 240 2 10 BOLT-ON 20 mmØ uPVC 20AT, 2P 20AT, 2P

5 1-1 HP, 8 A , WASHER AND DRYER 1 1840 8.00 2-3.5 mm2 THHN-2 CU. WIRE + 1-3.5 mm2 TW CU. WIRE (PE) 20 240 2 10 BOLT-ON 20 mmØ uPVC
S AB TWO GANG SWITCH C6 C7
6 7 - 20 W LED BULB 7 3 2 140 0.61 2-3.5 mm2 THHN-2 CU. WIRE 15 240 2 10 BOLT-ON 20 mmØ uPVC 15AT, 2P 15AT, 2P

7 5 - 20 W LED BULB 5 1 2 100 0.43 2-3.5 mm2 THHN-2 CU. WIRE 15 240 2 10 BOLT-ON 20 mmØ uPVC
S ABC THREE GANG SWITCH C8
30AT, 2P
8 SPARE 30 240 2 10 BOLT-ON 20 mmØ uPVC
TOTAL CONNECTED LOAD 12 16 2 4 4 0 0 6156 25.91
S 3W THREE WAY SWITCH
TOTAL FULL LOAD CURRENT, IFL = 25.91 A USE: 2 - 30 mm2 THHN CU. WIRE + 8.0 mm2 THHN CU. WIRE IN 30 mm Ø uPVC
CONDUCTOR AMPACITY, Ic = 32.39 A 1 - 50 AT, 2P, 20 KAIC, 230 V BOLT -IN CIRCUIT BREAKER
CIRCUIT BREAKER

GROUND SINGLE LINE DIAGRAM


KWH METER SCALE NTS
M

PREPARED FROM THE OFFICE OF: CERTIFIED AND SEALED BY: P.R.C NO.: 5833 PROJECT TITLE: APPROVED BY: SHEET CONTENTS: SHEET NO.:

P.T.R NO.: 9182135 SPECIFICATIONS

NIÑA MARIE P. ROBLES T.I.N NO.: 102-394-856


POWER LAY-OUT
LIGHTING LAYOUT
1
REGISTERED ELECTRICAL ENGINEER / MASTER ELECTRICIAN
ANTONIE M. UMAHAG DATE: 03-07-2019 PROPOSED ONE-STOREY RESIDENTIAL WADE Z. RIVAS
LEGEND
SCHEDULE OF LOADS AND DESIGN
E
ADDRESS: BRGY. AMAMAROS, POTOTAN, ILOILO
MOBILE: 09707979833
PROFESSIONAL ELECTRICAL ENGINEER ILOILO CITY OWNER
ANALYSIS
SINGLE-LINE DIAGRAM
1
Email: [email protected] ISSUED: LOCATION: LOT 16 WESTLAKE VILLA 3, BRGY. TANQUE, ROXAS CITY

You might also like