This document provides information about hand and mechanical directional valves including specifications, configurations, and characteristics. It details valve models, maximum flow and pressure ratings, recommended fluid types and temperatures, contamination class, and installation requirements.

Uploaded by

ebra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
146 views4 pages

Atos Hand & Mechanical Valves Overview

This document provides information about hand and mechanical directional valves including specifications, configurations, and characteristics. It details valve models, maximum flow and pressure ratings, recommended fluid types and temperatures, contamination class, and installation requirements.

Uploaded by

ebra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Atos spa Table E150-9/E

21018 Sesto Calende, Italy - Fax 0331 920005

Hand & mechanical directional valves


ISO/Cetop sizes 03, 05, 07 and 08

Hand & mechanical operated directio-


nal valves are spool type, three or four
way, two or three position, designed to
operate in oil hydraulic systems.
Available with:
DH-00
- mechanical actuator without lever;
- hand-lever;
- cam (only for ISO/Cetop 03 and 05).
Rugged execution suitable for outdoor
use.

DH-0 = ISO/Cetop 03 interface: flow up


to 50 l/min.
DP-21 DK-1 = ISO/Cetop 05 interface: flow up
to 100 l/min.
DP-2 = ISO/Cetop 07 interface: flow up
to 300 l/min.
DP-3 = ISO/Cetop 08 interface: flow up
to 650 l/min.

 body DH-02 Pressure up to 350 bar.


 spool
 mechanical actuator without lever
 lever
 cam

1 MODEL CODE

DH-0 1 1 3 /I ** /*
Directional control valve: Synthetic fluids:
DH-0 = ISO/Cetop 03 /WG = water-glycol
DK-1 = ISO/Cetop 05 /PE = phosphate ester
DP-2 = ISO/Cetop 07
DP-3 = ISO/Cetop 08

Design number
Type of actuator:
0 = mechanical, without lever Options:
1 = hand-lever /A = actuator device mounted on side of port B
2 = cam (only for DH-0 and DK-1) Only for hand-lever valves:
/C = short hand - lever and reducend actuation force
(only for DH-01)
Only for configuration 6, 7, 8, of hand-lever valves, see
Valve configuration, see section  section  and  for hydraulic connections:
0 = free, without springs /I = in rest position the lever is inclined towards the
1 = spring centered, without detent valve body
2 = retun to internal position (lever toward extern) /E = in rest position the lever is inclined in opposite side
3 = return to external position (lever toward the valve) Only for DK-1:
4 = 3 position, with detent /Y = external drain
5 = 2 external positions, with detent
6 = centre plus external positions, with detent
7 = return to external position from the centre position
8 = return to the centre position from the external position Spool type, see section 

2 HYDRAULIC CHARACTERISTICS

DH-00 DH-01 DH-02 DP-20 DP-21


(DK-10 is analogous) (DK-11 is analogous) (DK-12 is analogous) (DP-30 is analogous) (DP-31 is analogous)

Valve model DH-0 DK-1 DP-2 DP-3


Max recommended flow [l/min] 50 100 300 650
Max pressure on port P, A, B [bar] 350 315 350
Max pressure on port T [bar] 160 250

E150
3 MAIN CHARACTERISTICS OF HAND & MECHANICAL OPERATED DIRECTIONAL VALVES

Assembly position / location Any position.

Subplate surface finishing Roughness index 0,4 , flatness ratio 0,01/100 (ISO 1101)

Ambient temperature -20°C to + 70°

Fluid Hydraulic oil as per DIN 51524...535, for other fluids see section 

Recommended viscosity 15 ÷ 100 mm2/s at 40°C (ISO VG 15 ÷ 100)

Fluid contamination class ISO 19/16, achieved with in line filters at 25 µm value and ß25 ≥ 75 (recommended)

Fluid temperature T ≤ 80°C if T ≥ 60°C select /PE seals

4 VALVE CONFIGURATION

DH-011 DH-012 DH-013 DH-014 DH-015


DK-111 DK-112 DK-113 DK-114 DK-115

DH-016*/I DH-016*/E DH-016*/IA DH-017*/I DH-017*/E


DK-116*/I DK-116*/E DK-116*/IA DK-117*/I DK-117*/E

DH-016*/EA
DK-116*/EA

DH-017*/IA DH-018*/I DH-018*/E DH-018*/IA


DK-117*/IA DK-118*/I DK-118*/E DK-118*/IA

DH-017*/EA DH-018*EA
DK-117*/EA DK-118*/EA
DH-0230/2 DH-0232/2 DH-027* DH-028*
DH-0231/2 DK-1232/2 DK-127* DK-128*
DK-1230/2
DK-1231/2

DP-211* DP-212* DP-213* DP-214* DP-215*


DP-311* DP-312* DP-313* DP-314* DP-315*

DP-216*/I DP-216*/E DP-216*/IA DP-217*/I DP-217*/E


DP-316*/I DP-316*/E DP-316*/IA DP-317*/I DP-317*/E

DP-216*/EA
DP-316*/EA

DP-217*/IA DP-218*/I DP-218*/E DP-218*/IA


DP-317*/IA DP-318*/I DP-318*/E DP-318*/IA

DP-217*/EA DP-218*/EA
DP-317*/EA DP-318*/EA

(1) Where the symbol doesn't show the hydraulic connection (*), it depends by the central configuration of the spool, see table  .
(2) All the configuration shown for the lever operated valves are also available for valves actuated by mechanic without lever device.

5 SPOOLS - for intermediate passages, see tab. E001


NOTES
- Spools type 0/2, 1/2, 2/2 are only used for valves
0 3 6
0/2 type DH-023*/2 and DK 123*/2;
- Spools type 0 and 3 are also available as 0/1 and
3/1, where in centre position oil passage from ports
to tank are restricted;
1 4 7 - Spools type 1,4 and 5 are also available as 1/1, 4/8
1/2 and 5/1. They are properly shaped to reduce water-
hammer shocks during the switching;
- On request, other type of spools are available.
2 5 8
2/2
6 DIMENSIONS OF HAND & MECHANICAL OPERATED VALVES ISO/Cetop 03 [mm]

DH-00** DH-01**

DH-01**/C Mass: 1,6 Kg

Mass: 1,2 Kg

DH-02**

P
A B
T P = PRESSURE PORT
A, B = USE PORT
T = TANK PORT
For the max pressures on ports,
see section 

ISO/Cetop 03 MOUNTING SURFACE


Fastening bolts: 4 socket head screws M5 x 50
Diameter of ports A, B, P, T: Ø = 7,5 mm (max)
Working stroke: 2,5 mm; extra-stroke: 0,5 mm max. Mass: 1,2 Kg Seals: 4 OR 108
Mounting subplates: see tab. E010
7 DIMENSIONS OF HAND & MECHANICAL OPERATED VALVES ISO/Cetop 05 [mm]

DK-10** DK-11**

Mass: 2,5 Kg Mass: 2,8 Kg

DK-12**

P = PRESSURE PORT
A, B = USE PORT
T = TANK PORT
Y = DRAIN PORT
For the max pressures on ports, see
section 

Note: port Y is normally plugged;


for option /Y it must be connected
separately and directly to tank

ISO/Cetop 05 MOUNTING SURFACE


Fastening bolts: 4 socket head screws M6x40
Diameter of ports A, B, P, T: Ø = 11,2 mm (max)
Working stroke: 4 mm; extra-stroke: 0,5 mm max. Mass: 2,5 Kg Seals: 5 OR 2050

Mounting subplates: see tab. E020 E150


8 DIMENSIONS OF HAND & MECHANICAL OPERATED VALVES ISO/Cetop 07 [mm]

DP-20

ISO/Cetop 07 MOUNTING SURFACE


Fastening bolts:
4 socket head screws M10 x 50
2 socket head screws M6 x 40
Diameter of ports A, B, P, T : Ø = 20 mm
Diameter of ports X,Y: Ø = 7 mm
Seals: 4 OR 130, 3 OR 109

L A B Y
X
T P
Mass: 9,7 Kg

DP-21

P = PRESSURE PORT
A, B = USE PORT
T = TANK PORT
X = EXTERNAL OIL PILOT PORT not used
Y = DRAIN PORT
L = DRAIN PORT FOR HYDRAULIC CENTERING
DEVICE not used
For the max pressures on ports, see section 

Note: ports X, L are not used.


Port Y for drain must be connected directly to tank.
Mass: 10 Kg No counter pressure are allowed on Y port.
Mounting subplates: see tab. E075
9 DIMENSIONS OF HAND & MECHANICAL OPERATED VALVES ISO/Cetop 08 [mm]

DP-30

ISO/Cetop 08 MOUNTING SURFACE


Fastening bolts:
6 socket head screws M12 x 50
Diameter of ports A, B, P, T : Ø = 24 mm
Diameter of ports X,Y: Ø = 7 mm
Seals: 4 OR 4112, 3 OR 3056

X
A B
L
Y
T P
Mass: 15,2 Kg

DP-31

P = PRESSURE PORT
A, B = USE PORT
T = TANK PORT
X = EXTERNAL OIL PILOT PORT not used
Y = DRAIN PORT
L = DRAIN PORT FOR HYDRAULIC CENTERING
DEVICE not used
For the max pressures on ports, see section 

Note: ports X, L are not used.


Port Y for drain must be connected directly to
Mass: 15,5 Kg tank. No counter pressure are allowed on Y port.