Taizhou Tonhe Flow Control Co.
, Ltd
Email:[email protected] Skype:meizi2661
Mobile:+86-18957612187
URL:www.china-tonhe.com | www.tonheflow.com
A150 Series
A150 torque 15NM,with manual override,
Actuator model: turn on off type,proportional type, timer control type (optional)
Valve body model:
6.DN20-38
1.DN15-50 2.DN15-50 3.DN32-50 F03 4.DN15-25 5.DN15-32 3pcs
Sanitary Clamp
Pressure≤1.0MPa Pressure≤1.0MPa Pressure≤1.0MPa Pressure≤1.5MPa Pressure≤3MPa Pressure≤1.0MPa
2 way 3 way 2 way 3 way 2 way 2 way
PVC PVC SS304 SS316 SS304 SS316 SS304 SS316 SS304 SS316
Technical Parameters 开关型技术参数
Connection standard 连接标准 ISO5211 F03,F05
Output axis specification
Female octagonal 9*9 or 11*11
输出轴规格
Maximum working pressure
1.0MPa
最大介质压力
Rated voltage 额定电压 DC12V, DC24V, AC24V,DC12-24V, AC110-230v (Optional )
CR201,CR202,CR301,CR303,CR306,CR501,CR502,CR702,CR703,
Wiring diagram 接线图
CR706 (Optional)
Life time 寿命 70000 times(testing pressure is 0.4MPa, medium is water)
Actuator material 执行器材质 Engineering Plastics PPO
Torque force 扭力 15 N.m
Cable Length 线长 0.5m,1.5m (Optional )
Environment temperature
-15℃~60℃
环境温度
Liquid temperature 液体温度 2℃~90℃
Manual operation 手动操作 Yes
Open/close indicator 开关指示 Yes
Protection class 防护等级 IP67
1
Company quality management
ISO 9001:2015
system 公司认证
model specification and main performance parameters(Testing pressure is 0.4MPa, Medium is water)
Rated current(A) Number of
Wiring Open/
otation Power(W) manual
diagram close time
AC 24V DC 12V DC 24V turns
201/501 /
202/502 <0.78 <1 <0.5
301/702 90° ≤11 <0.3 <0.4 <0.2 <30W 8
303/703 <0.3 <0.42 <0.2
306/706 <0.78 <1 <0.5
2
A150 turn on/off type 2 way assembly diagram
3
A150 turn on/off type 3 way assembly diagram
4
Wiring diagram Turn on/off type
CR201(2 wires control)
·RD connect with positive, the BK connect with negative, the valve closed, the actuator automatically power off after in
place , the valve remains fully closed position .
·BK connect with positive, the RD connect with negative, the valve open, the actuator automatically power off after in place,
the valve remains fully open position .
﹡Suitable Working Voltage: DC12V, DC24V
﹡Exceeding the working voltage is forbidden
CR501(5 wires control,with feedback wire)
1. RD connect with positive, the BK connect with negative,the valve closed, the actuator automatically power off after
in place .
2 BK connect with positive, the RD connect with negative,the valve open, the actuator automatically power off after in
place .
4. GR & WT are connect when the valve open fully, YW & WT are connect when the valve closed fully
Suitable Working Voltage:DC12V, DC24V
Exceeding the working voltage is forbidden
Feedback wire capacity:
1. Voltage: DC0-35v; 2. Maximum current: 0.4A
5
CR202 (2 wires control--- Reset function, Normally closed or normally open)
·When SW is closed , the valve open. the actuator automatically power off after in place
·When SW is open, the valve closed, the actuator automatically power off after in place
﹡Suitable Working Voltage: AC24V,DC12-24V, AC110-230v
﹡Exceeding the working voltage is forbidden
Please Note A150 CR202 must need charge time >1 minute for every time use
CR502 ( 5 wires control,Reset function,With feedback signal)
·When SW is closed , the valve open. the actuator automatically power off after in place
·When SW is open, the valve closed, the actuator automatically power off after in place
﹡GR & WT are connect when the valve open fully, YW & WT are connect when the valve closed fully
﹡Suitable Working Voltage: AC24V,DC12-24V, AC110-230v
﹡Exceeding the working voltage is forbidden
Feedback wire capacity:
1. Voltage: DC0-35v; 2. Maximum current: 0.4A
Please Note A150 CR202 must need charge time >1 minute for every time use
CR301(3 wires control)
·RD & GR connect with positive, BK connect with negative
·When OPEN( RD) & SW connected , the valve open, the actuator automatically power off after in place , valve
remains fully open position
·When CLOSE(GR) & SW connected, the valve closed, the actuator automatically power off after in place, valve
6
remains fully closed position.
﹡Suitable Working Voltage: DC12V, DC24V,AC24v,DC12v-24v
﹡Exceeding the working voltage is forbidden
CR702(7 wires control)
1.RD & GR connect with positive, the BK connect with negative
2. When RD & SW connected, the valve open, the actuator automatically power off after the valve fully open.
3. When GR & SW connected, the valve closed, the actuator automatically power off after the valve fully closed,.
4. BL & GY connect with the valve’s fully open signal wiring
5. YW & WT connect with the valve’s fully closed signal wiring
﹡Suitable Working Voltage: DC12V, DC24V,AC24v,DC12v-24v
﹡Exceeding the working voltage is forbidden
Feedback wire capacity:
1. Voltage: DC0-35v; 2. Maximum current: 0.4A
CR3 03 Wiring Diagram (3 wires control )
·RD connect with positive, GR connect with SW & positive
·BK connect with negative
·When the SW of GR closed, the valve OPEN, the actuator automatically power off after in place , remains fully closed
position
·When the SW of GR open, the valve CLOSED, the actuator automatically power off after in place , remains fully open
position.
﹡Suitable Working Voltage: DC12V, DC24V,AC24v,DC12-24v, AC110-230v
﹡Exceeding the working voltage is forbidden
7
CR7 03 Wiring Diagram ( 7 wires control with feedback signal )
·RD& GR connect with positive, the BK connect with negative。
·SW CLOSED, the valve OPEN, the actuator automatically power off after in place
·SW OPEN, the valve CLOSED, the actuator automatically power off after in place.
·BL & GY connect with the valve’s fully open signal wiring
·YW & WT connect with the valve’s fully closed signal wiring.
﹡Suitable Working Voltage: DC12V, DC24V,AC24V,DC12-24V,AC110-230v
﹡Exceeding the working voltage is forbidden
Feedback wire capacity:
1. maximum voltage DC36V, AC220V; 2. maximum current 0.4 A.
CR3 06 Wiring Diagram ( 3 wires control – Power reset funtion)
1)Power off(failure), valve close
·RD& GR connect with positive, the BK connect with negative
·SW CLOSED, the valve close, the actuator automatically power off after in place
·SW OPEN, the valve open, the actuator automatically power off after in place.
Power off, valve close itself.
2)Power off(failure), valve open
·RD& GR connect with positive, the BK connect with negative
·SW CLOSED, the valve open, the actuator automatically power off after in place
·SW OPEN, the valve close, the actuator automatically power off after in place.
Power off, valve open itself.
﹡Suitable Working Voltage: AC24V,DC12V-24V,AC110-230v
﹡Exceeding the working voltage is forbidden
CR706(7 wires control)
8
1)Power off(failure), valve close
·RD& GR connect with positive, the BK connect with negative
·SW CLOSED, the valve close, the actuator automatically power off after in place
·SW OPEN, the valve open, the actuator automatically power off after in place.
Power off, valve close itself.
2)Power off(failure), valve open
·RD& GR connect with positive, the BK connect with negative
·SW CLOSED, the valve open, the actuator automatically power off after in place
·SW OPEN, the valve close, the actuator automatically power off after in place.
Power off, valve open itself.
·BL & GY connect with the valve’s fully open signal wiring
·YW & WT connect with the valve’s fully closed signal wiring.
﹡Suitable Working Voltage: AC24V,DC12V-24V,AC110-230v