Honeywell - Thermostat 2455R-00820191
Honeywell - Thermostat 2455R-00820191
Thermostats
TABLE OF CONTENTS
DESCRIPTION p. 1
NOMENCLATURE p. 2
DEFINITION OF TERMS p. 3
NOTES p. 3
COMMERCIAL THERMOSTATS
2450R/2450HR/2455R/2452R/2452HR Series Phenolic Automatic Reset p. 4
2450RC/2450RCH/2455RC Series Ceramic Automatic Reset p. 6
2455RM/2450CM Series Phenolic or Ceramic Manual Reset p. 9
2455RD Series Phenolic Manual Reset p. 11
2455RBV Series Overmolded Automatic Reset p. 13
2450A/2455RA Series Heat Detection p. 15
2450R/2455R/2450RC/2455RC/2450HR/2450RCH Series “One Shot” p. 17
REDI-TEMP THERMOSTATS
3455RC Series p. 19
MOUNTING HARDWARE
Brackets p. 20
Brass mounting studs p. 21
Terminals p. 22
Commercial Thermostats
NOMENCLATURE
The nomenclature given in Figure 1 is provided for reference only.
2 www.honeywell.com/sensing
DEFINITION OF TERMS
• Automatic Reset: A type of thermostat that will automatically reset at a specific temperature (i.e. a thermostat operates at
o o o o
65,5 C [150 F] and resets at 48,89 C [120 F]).
• Bimetal: Two dissimilar metals bonded together to form the material for manufacturing thermally-sensitive discs which actuate
the thermostat.
• Close on Rise (COR): Refers to operation of the contacts. When the temperature rises to its set point, the contacts close or
make contact and complete the circuit.
• Contact Resistance: The value of resistance measured between the terminals.
• Dielectric Strength: The value of insulation between two electrically conducting parts. It may be tested by the application of a
predetermined overvoltage for a specified time.
• Differential: The temperature difference between the operate and reset set points, also known as operate and reset.
- Nominal: The temperature difference between nominal set points regardless of tolerance.
- Maximum: Maximum number of degrees between actual opening and closing set points.
- Minimum: Minimum number of degrees between actual opening and closing set points.
• Exposure Temperature: Thermal environment of a device during application operation.
• FLA (Full Load Amps): Current taken from the line by the motor when the motor is yielding the rated hp at the rated voltage
and frequency.
• Life Cycles: The endurance rating of the thermostat expressed in number of operations with stated electrical load applied.
Temperature limit application = open on rise.
• LRA (Locked Rotor Amps): The amount of current the motor can be expected to draw under starting conditions when full
voltage is applied, also known as starting inrush current.
• Manual Reset: A bimetal thermostat with a reset button that must be pressed to reset the contacts.
• Open on Rise (OOR): Refers to the operation of contacts. When the temperature rises to its set point the contacts open,
terminating the circuit.
• Overmold: Encapsulation with an insulating material.
• Phenolic: Thermoset plastic used for the insulating body of the thermostat.
• Set Point: The nominal temperature at which the thermostat operates.
• SPST (Single Pole/Single Throw): A switch with one current path which can be either open or closed.
• Tolerance: The allowable range above and below the set point temperature.
• Operate: Change of state when the thermostat reaches its set point.
• Reset: Change of state when the thermostat returns to its original condition prior to operation.
NOTES
• Standard Temperature Characteristics Tables:
- Temperatures: Please consult applications engineering for temperature ranges, tolerances and differentials not noted.
The operating temperature ranges include tolerances.
- Tolerances: The ± tolerances given have been established after review of many thermostat applications. Attempts should
be made to establish the widest acceptable tolerance possible.
• UL and CSA Approvals: 12,7 mm [0.5 in] thermostats are available with multiple agency approval for incorporation into
equipment.
• Fan control applications: Require thermostat set points to be derated by 20 °C from the equivalent temperature limit
application. They also close on rise.
• Dimensions: Are for reference only and are given in mm [in].
4 www.honeywell.com/sensing
Table 2. 2450R/2450HR/2455R/2452R/2452HR Series Specifications
Characteristic Parameter
Switch type SPST
Reset type automatic
Amperage See Tables 3, 4
Voltage 120 Vac to 250 Vac
Operating temperature range 0 °C to 150 °C [32 °F to 302 °F]
Environmental exposure range -18 °C to 177 °C [0 °F to 350 °F]
Materials:
Base phenolic
Contacts silver alloy
Terminals unplated brass, plated brass or steel
Closure aluminum, brass or stainless steel
Brackets aluminum or stainless steel
UL and CSA approvals • 2455R: 6,35 mm [0.25 in] clearance; UL File MH8267, UL File E36103; CSA File LR21048
• 2450HR: 1,59 mm [0.0625 in] clearance; UL File E36103; CSA File LR21048
• 2450R: 1,59 mm [0.0625 in] clearance; UL File E36103; CSA File LR 21048
• 2452R: 2.66mm [0.105 in] clearance; UL E36103
• 2452HR: 2.66mm [0.105 in] clearance; UL36103
Weight 6 g [0.2 oz] (does not include brackets or wire leads)
2452R 2452HR
The 2450RC/2450RCH/2455RC Series is a single pole, All versions are UL/CSA and European approved.
single throw, snap-acting, non-adjustable thermostat which
may be used in applications such as industrial and electrical Potential applications include high temperature control for:
equipment. A temperature-sensitive bimetal disc, electrically • Power supplies
and thermally isolated from the switch, is used to actuate • Appliances
the normally-closed contacts. Contacts open when surface
or ambient temperatures increase to the operating set point • Medical equipment
of the calibrated metal disc. The entire switch is enclosed in • Water heaters
a ceramic housing; the bimetal disc is retained by a metal • Office automation
heat-conducting end cap. Due to the small size of this unit • Industrial equipment
and the inherently low mass of the bimetal snap-action disc,
response of this thermostat to temperature changes is • HVAC equipment
extremely rapid, compared to other commercially available
thermostatic devices. For increased sensitivity, an exposed
bimetal disc may be specified. A variety of mounting
brackets and terminals is available.
6 www.honeywell.com/sensing
Table 6. 2450RC/2450RCH/2455RC Series Standard Temperature Characteristics (continued)
Operating Temperature Range Tolerance Standard Mean Differential
Open Close °C [°F]
°C [°F] °C [°F]
±7 [±12] ±10 [±18] 45 to 56 [81 to 100]
±5 [±9] ±8 [±15] 34 to 45 [61 to 80]
111 °C to 149 °C ±5 [±8] ±7 [±12] 28 to 34 [50 to 60]
[231 °F to 300 °F] ±4 [±7] ±7 [±12] 22 to 27 [40 to 49]
±4 [±7] ±6 [±11] 17 to 22 [30 to 39]
±4 [±7] ±6 [±10] 14 to 16 [25 to 29]
±8 [±15] ±11 [±20] 39 to 45 [71 to 80]
150 °C to 170 °C ±6 [±10] ±11 [±20] 34 to 39 [61 to 70]
[301 °F to 335 °F] ±6 [±10] ±8 [±15] 28 to 33 [50 to 60]
±6 [±10] ±7 [±12] 22 to 27 [40 to 49]
±14 [±25] ±14 [±25] 51 to 56 [91 to 100]
171 °C to 220 °C
±11 [±20] ±11 [±20] 39 to 50 [71 to 90]
[336 °F to 425 °F]
±8 [±15] ±11 [±20] 28 to 39 [50 to 70]
±14 [±25] ±14 [±25] 51 to 56 [91 to 100]
221 °C to 235 °C
±11 [±20] ±11 [±20] 39 to 50 [71 to 90]
[426 °F to 450 °F]
±8 [±15] ±11 [±20] 28 to 39 [50 to 70]
236 °C to 260 °C ±14 [±25] ±14 [±25] 31 to 56 [60 to 100]
[451 °F to 500 °F] ±11 [±20] ±11 [±20] 28 to 50 [50 to 90]
8 www.honeywell.com/sensing
Figure 6. 2455RM/2450CM Series Phenolic or Ceramic Manual Reset Thermostats
The 2455RM (phenolic)/2450CM (ceramic) Series is a All versions are UL/CSA, European approved.
single pole, single throw, snap-acting, non-adjustable
thermostat. A temperature-sensitive bimetal disc, electrically Potential applications include those where a manual reset is
and thermally isolated from the switch, is used to actuate desired, including:
the normally-closed contacts. Contacts open when surface
or ambient temperatures increase to the operating set point • Power supplies
of the calibrated bimetal disc. The entire switch is enclosed • Appliances
in a housing; the bimetal disc is retained by a metal heat-
conducting end cap. The circuit remains open above the • Medical equipment
room ambient temperature until the manual reset button is • Water heaters
depressed. Due to the small size of this unit and the • Office automation
inherently low mass of the bimetal snap-action disc, • Industrial equipment
response of this thermostat to temperature changes is
extremely rapid, compared to other commercially available • HVAC equipment
thermostatic devices. For increased sensitivity, an exposed
bimetal disc may be specified. A variety of mounting
brackets and terminals is available.
NOTICE
• 2455RM/2450CM thermostats are intended as a manual reset control. They are not to be used on applications where a limit
thermostat is required unless back-up protection is provided. Units have been tested by UL for 1,000 cycles under load,
5,000 cycles no load, and are not considered as limit devices.
• This range of thermostats has an automatic reset function with manual override function.
• Reset pin operation should not be performed above 70% of set point temperature.
10 www.honeywell.com/sensing
Figure 8. 2455RD Series Phenolic Manual Reset
The 2455RD Series is a single pole, single throw, snap- All versions are UL/CSA and European approved.
acting, non-adjustable thermostat. A temperature-sensitive
bimetal disc, electrically and thermally isolated from the Potential applications include those where a manual reset is
switch, is used to actuate the normally-closed contacts. desired, including:
Contacts open when surface or ambient temperatures
increase to the operating set point of the calibrated bimetal • Power supplies
disc. The entire switch is enclosed in a housing; the bimetal • Appliances
disc is retained by a metal heat-conducting end cap. The
circuit remains open above the room ambient temperature • Medical equipment
until the manual reset button is depressed. (These devices • Water heaters
are constructed with an additional steel disc so that they are • Office automation
manual reset only. They do not have an automatic reset.) • Industrial equipment
Due to the small size of this unit and the inherently low
mass of the bimetal snap-action disc, response of this • HVAC equipment
thermostat to temperature changes is extremely rapid,
compared to other commercially available thermostatic
devices. For increased sensitivity, an exposed bimetal disc
may be specified. A variety of mounting brackets and
terminals is available.
12 www.honeywell.com/sensing
Figure 10. Series 2455RBV Overmolded Automatic Reset Thermostats
The 2455RBV Series has a temperature-sensitive bimetal This series is UL/CSA and European approved.
disc, electrically and thermally isolated from the switch that
is used to actuate the normally closed contacts. The Potential applications include:
contacts open when surface or ambient temperatures • Automotive
increase to the operating set point of the calibrated bimetal • Industrial equipment
disc. The entire switch is enclosed in a phenolic or ceramic • HVAC
housing; the bimetal disc is retained by a metal heat-
conducting end cap. The unit is then encapsulated in epoxy.
A
B
18,54
[0.730]
14 www.honeywell.com/sensing
Figure 12. 2450A/2455RA Heat Detection Thermostats
The 2450A/2455RA Series is a single pole, single throw, All versions are UL approved.
snap-acting, non-adjustable thermostat designed for easy
mounting in devices such as fire alarms, security devices Potential applications:
and smoke detectors. A temperature-sensitive bimetal disc, • Smoke alarm/heat detectors in industrial, residential and
electrically and thermally isolated from the switch, is used to commercial
actuate the normally-closed contacts. Contacts open when
surface or ambient temperatures increase to the operating
set point of the calibrated bimetal disc. Devices are UL
recognized and designed for use in both photoelectric and
ionization type smoke detectors. Thermostats are available
with and without collectors and meet UL spacing
requirements for 15 ft, 30 ft and 50 ft. They are available to
° °
open or close on a temperature rise of 47 C [117 F] to
° °
107 C [225 F]. Devices feature gold contacts for low
voltage requirements and are epoxy sealed at the cap and
terminal for long storage life of the application. Collectors
are available in silver, black, beige, gold or bronze finishes.
NOTICE
Final approval of a fire detection system is determined by UL as outlined in UL #521 and UL #217 for the suitability of the
combination of the thermostat (2450A/2455RA) and the user’s mounting base, together with its intended application of the total
fire detection system. To assist the use with design and testing , a minimum of 0.25 in extension beyond the housing is
recommended.
Figure 14. 2450A/2455RA Collector Figure 15. 2450A and 2455RA Spacing
B247 2450A: 4,6 m [15 ft] 2455RA with B247A: 15,2 m [50 ft]
16 www.honeywell.com/sensing
Figure 16. 2450R/2455R/2450RC/2455RC/2450HR/2450RCH Series “One Shot” Thermostats
The 2450R/2455R/2450RC/2455RC/2450HR/2450RCH All versions are UL/CSA approved and European approved.
Series “One Shot” is a single pole, single throw, snap-
acting, non-adjustable thermostat designed as a high limit Potential applications include:
device for applications where automatically resettable • Power supplies
thermostats are not desirable. A temperature-sensitive • Appliances
bimetal disc, electrically and thermally isolated from the
switch, is used to actuate the normally-closed contacts. • Medical equipment
Contacts open when surface or ambient temperatures • Water heaters
increase to the operating set point of the calibrated bimetal • Office automation
disc. The entire switch is enclosed in a housing; the bimetal • Industrial equipment
disc is retained by a metal heat-conducting end cap. The
circuit remains open above the room ambient temperature • HVAC equipment
and will reset below -35 °C [-31 °F]. For increased
sensitivity, an exposed disc may be specified. A variety of
mounting brackets and terminals is available.
18 www.honeywell.com/sensing
REDI-TEMP THERMOSTATS
REDI-TEMP thermostats are pre-configured as shown and are readily available.
Figure 18. 3455RC REDI-TEMP Series (See page 6 for specifications and potential applications.)
3455RC B203S Moveable Bracket
23,80
32,26 [0.937]
[1.270]
2X 3,56 DIA
[0.140]
17,55
[0.691]
2X 1,7 DIA
[0.067]
31,19
[1.228]
11,9
0.51 [0.469]
[0.20]
Table 25. 3455RC REDI-TEMP Series Open on Rise Table 26. 3455RC REDI-TEMP Series Close on Rise
Catalog Open Open Close Close Catalog Close Close Open Open
Listing Temp. Tolerance Temp. Tolerance Listing Temp. Tolerance Temp. Tolerance
°C [°F] °C [°F] °C [°F] °C [°F] °C [°F] °C [°F] °C [°F] °C [°F]
3455RC-100-220 18 [65] ±3 [±5] -1 [30] ±5 [±8] 3455RC-100-243 21 [70] ±5 [±8] 2 [35] ±3 [±5]
3455RC-100-221 24 [75] ±3 [±5] 4 [40] ±5 [±8] 3455RC-100-244 32 [90] ±5 [±8] 16 [60] ±3 [±5]
3455RC-100-222 29 [85] ±3 [±5] 13 [55] ±5 [±8] 3455RC-100-245 43 [110] ±5 [±8] 27 [80] ±3 [±5]
3455RC-100-223 35 [95] ±3 [±5] 18 [65] ±5 [±8] 3455RC-100-246 54 [130] ±5 [±8] 38 [100] ±3 [±5]
3455RC-100-224 41 [105] ±3 [±5] 24 [75] ±5 [±8] 3455RC-100-247 66 [150] ±5 [±8] 49 [120] ±3 [±5]
3455RC-100-225 46 [115] ±3 [±5] 29 [85] ±5 [±8] 3455RC-100-248 77 [170] ±5 [±8] 60 [140] ±3 [±5]
3455RC-100-226 52 [125] ±3 [±5] 35 [95] ±5 [±8] 3455RC-100-249 88 [190] ±5 [±8] 71 [160] ±3 [±5]
3455RC-100-227 57 [135] ±3 [±5] 41 [105] ±5 [±8] 3455RC-100-250 99 [210] ±5 [±8] 82 [180] ±4 [±6]
3455RC-100-228 63 [145] ±3 [±5] 46 [115] ±5 [±8] 3455RC-100-251 110 [230] ±5 [±8] 93 [200] ±4 [±6]
3455RC-100-229 68 [155] ±3 [±5] 52 [125] ±5 [±8] Note: Materials and contact ratings are the same as those for 2455RC.
A Enclosed B Exposed
B-203S B-206 B-207
3,96
[0.156]
43,05
[1.695] 34,11
[1.343]
25.40 DIA
[1.000]
8,71 R
[0.343]
12,70
[0.500]
20 www.honeywell.com/sensing
Figure 19. Brackets (Continued)
B-246 B-249 B-250
B-264
4,1 5,0
[0.062] [0.17]
M4 X 0.7
34,93
[1.375]
15,85
25,40 [0.624]
[1.000]
4,90 DIA
[0.193] 1,70 DIA
[0.067]
8,64
[0.340]
1,32 [0.052]
3,86 [0.152]
4.57 [0.180]
6.10 [0.240]
27,59
[1.086]
45°
6,16
[0.242]
62,18
[2.448]
3,18
[0.125]
2,79
[0.110] 1,27
[0.050]
22 www.honeywell.com/sensing
Figure 21. Terminals (Continued)
T-179 T-188 T-806 T-807
Vertical Weld Inside Vertical Weld Outside
12,90 2,54
[0.508] [0.100]
Authorized Distributor
Honeywell:
2450CM 00020410 2450CM 00820670 2450CM 00950158 2450CM 02150037 2450CM 05170009 2450CM
80020577 2450CM 80020620 2450CM 80020671 2450CM 80020691 2450CM 80040416 2450CM 80820817
2450CM 80821030 2450CM 81000460 2450CM 82090117 2450CM 82090123 2450CM 83250021 2450CM
86750001 2450CMG81840033 2450CMG86980002 2450CMN80821029 2450HR 00010484 2450RC 00040225
2450RCH82000051 2455RBV00290011 2455RBV01170246 2455RBV01170281 2455RBV04490022
2455RBV81170364 2455RBV81170399 2455RBV81170400 2455RBV81510030 2455RBV81510031
2455RBV81510042 2455RBV82290018 2455RBV82290019 2455RBV82340039 2455RBV82340041
2455RBV83630009 2455RBVG8117346 2455RC 00580071 2455RC 00820321 2455RC 80820961 2455RC
81000381 2455RC 81740206 2455RC 82570107 2455RC260040208 2455RC350020533 2455RC350020675
2455RC350020697 2455RC350040503 2455RC350040506 2455RC350040508 2455RC350040510
2455RC350580177 2455RC350950201 2455RC350950223 2455RC356380025 2455RC356780014 2455RM
80820759 2455RM 80980239 2455RM 82850114 2455RM 82850115 2455RMG81460089 3455RC 00020255
3455RC 00420137 3455RC 00820550 3455RC 00820579 3455RC 00820608 3455RC 00980224 3455RC 01130093
3455RC 01130104 3455RC 02040015 3455RC 02570056 3455RC 02990006 3455RC 02990007 3455RC
03070016 3455RC 05070003 3455RC 05070007 3455RC 05340004 3455RC 06020002 3455RC 06020005
3455RC 80040405 3455RC 80040477 3455RC 80420241 3455RC 80560163 3455RC 80580174 3455RC 80810085
3455RC 80980228 3455RC 81000396 3455RC 81740140 3455RC 81740145 3455RC 81740181 3455RC
81740188 3455RC 81890038 3455RC 83070027 3455RC 86120003 3455RC 86620006 3455RC350020554
2450CM 01460035 2450CM 01460036