0% found this document useful (0 votes)
47 views8 pages

Series LR5000E24-23B

The LR5000 series data loggers from Hioiki feature expanded memory and easy-to-use compact designs for long-term recording of temperature, voltage, current and other signals. The loggers offer 7 times more recording capacity than previous models, continuous measurement during battery replacement, and intuitive software. Flexible and versatile for single or multiple location use, the loggers are well-suited for applications requiring simple setup and reliable long-term data collection.

Uploaded by

shijinjahamgir
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
47 views8 pages

Series LR5000E24-23B

The LR5000 series data loggers from Hioiki feature expanded memory and easy-to-use compact designs for long-term recording of temperature, voltage, current and other signals. The loggers offer 7 times more recording capacity than previous models, continuous measurement during battery replacement, and intuitive software. Flexible and versatile for single or multiple location use, the loggers are well-suited for applications requiring simple setup and reliable long-term data collection.

Uploaded by

shijinjahamgir
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

DATA LOGGER LR5000 Series

Complete Line of Easy-to-Use


Compact Loggers with Expanded Memory
The new HIOKI compact data logger series easily records temperature, voltage,
current, and instrumentation signals over long periods. Carried over from its highly
reputed predecessor, this series includes features and functions such as 7 times
the recording capacity of former models, data import during recording, continuous
measurement even during battery replacement, and intuitive PC software. Flexible
and easy-to-use at single and multiple locations, the new HIOKI compact data
logger series is ideal for any application that requires simple set-up but long-term,
reliable recording capabilities.
2

Meet a Wide Variety of Data Logging Applications

Temperature Logger /Humidity Logger Instrumentation Logger / Voltage Logger


Manage the temperature and humidity in offices and facto- Record fluid flow such as for water, gas and oil. Measure
ries. Visually monitor the data to save on air-conditioning flow meter output signals to monitor flow trends.
and heating costs.

Clamp Logger
Manage the current consumption of plant and building
equipment. Visually monitor power costs to efficiently con-
duct energy- and cost-saving activities.

Use as a Voltage Logger to record pyranometer output for Use as a Clamp Logger and leakage sensor to record and
evaluating insulation. monitor leakage trends.

pyranometer

Voltage logger has a Preheat function

Use as a Temperature Logger to record warehouse temperatures for Use as an Instrumentation Logger to record pressure sensor
visually monitoring temperature changes of products and goods. output and monitor fluctuations in air or oil pressure.
3

Easy operation in just steps !


Install a Data Logger, set an interval, and start measuring.

Easy to start recording Unlimited installation capabilities

STEP Wall-mounted Holder


(sold separately)
Not usable with LR5051

Set up
&Record Set your recording interval. Hold the REC button
Magnetic Strap
(sold separately)
(from one second to 60 minutes) for two seconds to
Kickstand
start recording. (included, except
for Model LR5051)

Download data
using infrared Grab the Data Logger from the worksite and connect to a PC.
communication.

STEP Communication Adapter


Transfer data LR5091
Retrieving the Transfer data from Data Logger to

from Data Logger


Data Logger PC using a USB connection

to PC Using the Data Collector's internal memory, import data from up to 16 Data
Loggers installed on site.*
Download data

!
using infrared
communication.
Requires optional

Communication
Adapter
Importing to Retrieving Transfer data from Data Logger to
or
a Data Collector the Data Collector PC using a USB connection

Data Collector Front Back


* Data for up to 16 channels can be stored. Combine up to 16 single-channel Data Loggers (Models LR5011, LR5031,
LR5041, LR5042, and LR5043), or up to eight 2-channel Data Loggers (Models LR5001, and LR5051).
Data Collector
LR5092-20 Using an optional SD Memory Card, the amount of data that can be import-
ed is practically limitless.

Top surface of LR5092-20

SD Card slot
or
USB Connector
Importing to an Transfer data from SD Memory Card Transfer data directly
SD Memory Card within Data Collector to PC using USB from SD Memory Card

View data graphically and easily print using the bundled software.

STEP
View graphs
and manage
data
4

Advanced Features and Functions


Install Almost Anywhere Recording capacity up to 7 times previous models
Easily mount the light-weight, pocket-sized loggers in Large internal memory stores 60,000 data points per
tight spaces. channel. Long-term recording capability exceeds that
of previous models.
Interval Instantaneous value Statistical value
times
1s 16h 40m -
2s 1d 9h 20m 8h 20m
5s 3d 11h 20m 20h 50m
10s 6d 22h 40m 1d 17h 40m
15s 10d 10h 2d 14h 30m
20s 13d 21h 20m 3d 11h 20m
30s 20d 20h 5d 5h
1m 41d 16h 10d 10h
2m 83d 8h 20d 20h
5m 208d 8h 52d 2h
10m 416d 16h 104d 4h
15m 625d 156d 6h
20m 833d 8h 208d 8h
30m 1250d 312d 12h
Actual size
60m 2500d 625d
The maximum recording time depends on battery life.
The battery may need to be replaced during long-term recording.
Easy-to-see dual display Customers using the previous Model 3636-20 Clamp Logger
Temperature and humidity or current channels can be should note that the LR5051 can only record 15,000 points of
displayed. View maximum and minimum values while average data, vs. 32,000 data points available in the 3636-20.
measuring.

Moist environments Record without missing fluctuations


IP54 splash-proof rating withstands With usual (instantaneous value) recording at long inter-
operation in extremely humid vals, detailed fluctuations occurring within the intervals
environments like kitchens and pipe are missed. However, with the statistical value recording
rooms. (Except Model LR5051) mode, detailed fluctuations are captured even when they
occur during long recording intervals. In STAT mode,
measurement is taken every second, and the maximum,
minimum, average, and instantaneous values within the
specified interval are recorded.
Data interval(2sec to 60min)

Transfer data even during recording 1sec

Continue to record even when transferring data.


Data interval(2sec to 60min) Maximum
data
Maximum
data
Transfer data
from Data Logger
to PC!
Average Instant
data data

In the middle of
Recording ... Average
data
Instant
data
Input signal Minimum
(Temperature, data
Voltage, etc.) Minimum Time
data

Record 4 data Record 4 data


Batteries last up to 2 years for interval for interval

Energy-efficient design provides up to two years of


battery life (For the LR5011 only. Actual battery life de-
pends on model type and settings). Never worry about a dead battery
The worry-free backup function preserves measurement
data even after the battery dies.

Replace batteries while recording Never worry about operating errors


Recording continues for about 30 Worry-free backup preserves recorded data even if a
seconds even with the battery removed. Note. With the LR5001, new measurement is started by mistake.
re c o rd i n g i s i n t e r r u p t e d
during battery replacement

!
if the battery is very weak.
After batteries are replaced,
recording resumes automati-
cally. Previously recorded
data is not lost during battery
replacement.
5

Bundled Software Ensures Smooth and Easy Data Analysis


Import data to a PC and create graphs
Use the LR5000 Utility program to import Data Logger
data to a PC to make graphs and analyze data further.
Easily print results using your PC.

Show specific values using the cursor function


Use the A/B cursors to select any location on a graph and dis-
play its value. The PC software can also calculate maximum,
minimum, and average values between A and B cursors.

Simple file aggregation and management


Transferred data can be combined with data previously
transferred (from the same Data Logger unit) into one
data on the PC.

Past data New data Saving 1 file

Display data from former Data Logger models


The PC application also supports data collected from the HIOKI
36XX Series Data Loggers.

Print graphs
Print function Print statistical data.
Scaling
LR5000 Utility Specifications Power calculation
•Import/export Data Logger settings (LR5091 or Energy cost calculation
Data processing Operating ratio calculation
Configurating LR5092-20 required) Integration
Data Logger •Settings sent to each LR5000 logger are also saved Dew point temperature
to the PC. Calculate between channels
•Graphically display data for up to 16 channels OS: Windows 7/ Windows 10
•Select colors and display/hide any channel and graph CPU: 1GHz or more
Operating Memory: 1 GB or more (32 bit), 2 GB or more(64 bit)
Graph display •Copy graph images to clipboard environment Library: .NET Framework 4.5.2 or later
•Display statistical data (maximum, minimum and average) Interface: USB
•Scaling function Free space in hard disk:30MB or more
6

Communication Adapter and Data Collector Specifications

Physical
appearance

Model Communication Adapter LR5091 Data Collector LR5092-20


•Collect recorded data from the Data Logger to internal memory or SD card
•View collected data in a graph
•Transfer data from a Data logger to a PC •Transfer Data Logger configurations or clock settings from internal
Features •Transfer Data Logger configurations or clock settings memory or SD card to the Data Logger
from a PC to the Data Logger •Transfer data from a Data Logger to a PC
•Transfer Data Logger configurations or clock settings from a PC to
the Data Logger
Interface with
Infrared optical communications
Data Logger
Interface with PC USB2.0, Full Speed, Series Mini B Receptacle
Clock functions - Auto calender, auto leap year
Display - Dot-matrix LCD (128 × 64 dots)
Data Logger configurations (Interval, Start/Stop method, Recording
Display items - mode, Scaling, Alarm, Power-saving mode, Clock, Range)
Collected data (Record list , Maximum data, Minimum data, Average, Graph, Value)
Internal memory 60,000 data elements ×16ch (instantaneous value mode)
-
capacity of data 15,000 data elements ×16ch (statistical value mode)
Removable stor- SD Card (SDHC, Max 32GB)
-
age media Save data and configurations
Operating environment Indoors
DC 3 V (LR6 (AA) Alkaline battery 1.5 V×2) or DC 5 V (USB bus power)
Power supply DC 5 V (USB bus power) Maximum rated power 0.5 VA
Maximum rated power 1 VA
Battery life - Approx. 12 hours or 500 times of data collection
Operating temperature
0˚C (32˚F) to 40˚C (104˚F) , 80% RH or less (non-condensating)
and humidity
83 mm (3.27 in)W × 61 mm (2.40 in)H × 19mm (0.75 in)D, 91 mm (3.58 in)W × 141 mm (5.55 in)H × 31 mm (1.22 in)D,
Dimensions & Mass
43 g (1.5 oz) 215 g (7.6 oz) (excluding batteries)
Instruction manual ×1, Operation manual×1,
USB cable (1 m)×1,
Accessories LR6 (AA) Alkaline battery 1.5V×2, USB cable (1 m)×1,
CD (Application software "LR5000 Utility") × 1
CD (Application software "LR5000 Utility") × 1

LR5092-20 Option

SD Memory Card (2GB) Z4001

LR5000 Series Common specifications


(Accuracy guaranteed for 1 year)

Instantaneous value mode 60,000 data sets per channel


Recording 1/ 2/ 5/ 10/ 15/ 20/ 30 seconds
Storage capacity Statistical value mode 15,000 data sets per channel
interval 1/ 2/ 5/ 10/ 15/ 20/ 30/ 60 minutes Note.Customers using the previous Model 3636-20 Clamp Logger should note that the LR5051 can
only record 15,000 points of average data, vs. 32,000 data points available in the 3636-20.

Measured value, Interval configration, Date, Time,


One time recording Display items Alarm, Remaining battery power, Number of data,
Stop recording when the memory capacity is full. Maximum data, Minimum data
Recording
Endless recording
methods Recording start
Continue recording even when the memory capacity is full.
Manual start
(old data is overwritten.)
Timer start
Recording Recording stop
Instantaneous recording start / stop Manual stop
Recording modes Instantaneous values are recorded at every Timer stop
recording interval. When the memory capacity is full
(instantaneous
Statistical value recording (One time recording)
value mode/ Measure at one second intervals, and record the
statistical value instantaneous, maximum, Data from the last recording session is always backed up.
mode) minimum, and average values within every recording Data backup
interval. Back up recorded data and configuration when battery is dead.

LR5000 Series common options Interface Infrared optical communications with LR5091, LR5092-20

Magnetic Strap Wall-mounted Holder During battery replacement, recording and clock operations
Z5004 LR9901 are preserved for about 30 seconds. (Recording operation
Not compatible with Model LR5051 Power supply continues if the battery is replaced within about 30 seconds.)
Note. With the LR5001, recording is interrupted during battery replacement if the
battery is very weak. After batteries are replaced, recording resumes automatically.
Previously recorded data is not lost during battery replacement.
7
Analysis of measurement data on a PC requires the optional LR5091 Communication Adapter or LR5092-20 Data Collector. See page 6 for details.
Product Specifications (Accuracy guaranteed for 1 year) See page 6 for Common specifications

Physical
appearance
Bundled sensor (LR9504) Optional sensor (LR9604)
(Sensor is out of warranty) (Sensor is out of warranty)

Model HUMIDITY LOGGER LR5001 TEMPERATURE LOGGER LR5011


Temperature and humidity are recorded simultaneously using Temperature measurement with external temperature sensor.
Features supplied or optional temperature and humidity sensors. Select the sensor according to the measurement object
Measurement
Temperature 1ch and Humidity 1ch Temperature 1ch
items
Measurement Temperature : -40˚C to 85˚C -40.0˚C to 180˚C
range Humidity : 0% to 100% RH *Depends on measurement range of sensor.
Temperature Humidity (LR5001+Sensor) (LR5011+Sensor)
(LR5001 + Sensor) 100
180

Temperature : ˚C
Relative humidity : %rh ±5.0˚C
90
*±10
10%rh ±1010%rh ±8 8%rh ±10 10%rh
Temperature : ˚C

85 120
±2.0˚C 70 *±8 %rh ±8 %rh ±6 ±8 ±2.0˚C

15%rh
70 8 8 6 %rh 8%rh
70

±15
Accuracy ±1.0˚C 50 *±6 ±1.0˚C
35 6 %rh ±6
6 %rh ±5
5 %rh ±6
6%rh * 35
±0.5˚C ±0.5˚C
0 10
0
±1.0˚C 0 ±1.0˚C
-40 -40 0 10 20 30 50 85
-40
Temperature : ˚C
* Values provided for reference only.
Waterproof and dust-
IP54 (splash-proof construction)
proof performance
Operating temperature
-20˚C (-4˚F) to 70˚C (158˚F) , 80% RH or less (non-condensating)
and humidity
Dimensions & Approx. 79 mm (3.11 in)W × 57 mm (2.24 in)H × 28 mm (1.10 in)D
mass 105 g (3.7 oz)
Power supply LR6 (AA) Alkaline battery 1.5 V×1
Humidity sensor LR9504×1, Kickstand Kickstand
Accessories
LR6 (AA) Alkaline battery 1.5 V×1, Instruction manual ×1, Operation manual×1
Case 1 : Approx. 3 months Case 2: Approx. 20 days Case 1 : Approx. 2 years Case 2: Approx. 2 months
Battery life Case 1 : 1min. recording interval, power-saving mode, Instantaneous recording, environmental temp.20˚C
Case 2 :1sec. recording interval, power-saving mode, Instantaneous recording, environmental temp.20˚C
(Reference) When the recording interval is set to 10 minutes, the LR5001 Temperature and Humidity Logger can measure for about one year between battery replacements.

LR5001 Options Humidity Sensor


n Humidity Sensor
30 mm (Thickness : 8 mm) lModels (length) : LR9501 (1 m)
13 mm
LR9502 (5 m)
LR9503 (10 m)
1 m (LR9501)
5 m (LR9502) LR9504 (40 mm, bundled accessory)
10 m (LR9503)
lTemperature range : -40.0˚C to 85.0˚C
lHumidity range : 0.0% to 100.0% RH
40 mm lResponse time : Approximately 300 seconds
(LR9504) (Temperature and humidity; 90% response time)

LR5011 Options Temperature Sensor


n Molded plastic type n Lug type
diameter:6 mm 28 mm

Outer diameter:7 mm 1 m (LR9611)


1 m (LR9601) Inner diameter:3.2 mm
5 m (LR9602) 5 m (LR9612)
10 m (LR9603) 10 m (LR9613)

45mm (LR9604)
lModels (length) : LR9601 (1 m) LR9602 (5 m) lModels(length) : LR9611 (1 m) LR9612 (5 m)
LR9603 (10 m) LR9604 (45 mm) LR9613 (10 m)
lTemperature range : -40˚C to 180˚C lTemperature range : -30˚C to 180˚C
lResponse time : Approx. 100 seconds (90% response time) lResponse time : Approx. 45 seconds (90% response time)
lMaterial : Cable : Silicon Sensor head : Silicon lMaterial: Cable : Silicon Sensor head : Nickel-plated brass

n Sheathed type n Needle type


180 mm 25 mm

diameter 4 mm diameter 1.3 mm


1m 1m

lModels(length) : LR9621(1 m) lModels(length) : LR9631(1 m)


lTemperature range : -40˚C to 120˚C lTemperature range : -40˚C to 120˚C
lResponse time : Approx. 90 seconds (90% response time) lResponse time : Approx. 20 seconds (90% response time)
lMaterial : Cable : Silicon Sensor head : SUS304 lMaterial : Cable : Silicon Sensor head : SUS304
Analysis of measurement data on a PC requires the optional LR5091 Communication Adapter or LR5092-20 Data Collector. See page 6 for details.
Product Specifications (Accuracy guaranteed for 1 year) See page 6 for Common specifications

Physical
appearance
Bundled accessory Bundled accessory
(LR9801) (LR9802)
LR5042(5V)

Model INSTRUMENTATION LOGGER LR5031 VOLTAGE LOGGER LR5041, LR5042, LR5043


For recording instrumentation signals and measuring analog outputs from
Features For recording 4-20 mA instrumentation signals, etc. sensors and other devices
Measurement items For Instrumentation / 0 to 20 mA DC, 1ch DC voltage 1ch

Measurement LR5041: -50.00 mV to 50.00 mV


DC -30.00 to 30.00 mA LR5042: -5.000 V to 5.000 V
range LR5043: -50.00 V to 50.00 V
Accuracy ±0.5% rdg. ±5 dgt. (@23˚C ±5˚C) ±0.5% rdg. ±5 dgt. (@23˚C ±5˚C)
Waterproof and dust-
IP54 (splash-proof construction)
proof performance
Operating temperature
-20˚C(-4˚F) to 70˚C(158˚F) , 80% RH or less (non-condensating)
and humidity
Dimensions & Mass Approx. 79 mm (3.11 in)W × 57 mm (2.24 in)H × 28 mm (1.10 in)D, 105 g (3.7 oz)
Power supply LR6 (AA) Alkaline battery 1.5 V×1
Connection Cable LR9801×1, Kickstand Connection Cable LR9802×1, Kickstand
Accessories
LR6 (AA) Alkaline battery 1.5 V×1, Instruction manual ×1, Operation manual×1
Case 1 : Approx. 2 years Case 2: Approx. 2 months
Battery life Case 1 : 1min. recording interval, power-saving mode, Instantaneous recording, environmental temp.20˚C
Case 2 : 1 sec. recording interval, power-saving mode, Instantaneous recording, environmental temp.20˚C
Other - Preheat function (When using preheat function, a separate external power supply is required.)
For LR5031 For LR5041, LR5042, LR5043
2 wires 4 wires
1m 1m

CONNECTION CABLE LR9801(Bundled accessory) CONNECTION CABLE LR9802 (Bundled accessory)

Product Specifications (Accuracy guaranteed for 1 year) LR5051 Options


See page 6 for Common specifications Load current
3 m (9.84 ft) cord length 3 m (9.84 ft) cord length Connection cord 9219 is
(Sensor warranty is required (sold separately)
one year)
Physical Insulated
Physical conductor
*Sensor is sold separately. appearance
appearance *For customers using the previous Model 3636-20
Clamp Logger, please note the difference in record-
able average data points available in the LR5051. Not CE marked
(Please refer to page 4.) Model CLAMP ON SENSOR 9669 CLAMP ON SENSOR CT6500 CLAMP ON SENSOR 9695-02
Model CLAMP LOGGER LR5051 Measurable con- φ55 mm (2.17") or less,
φ46 mm (1.81") or less φ15 mm (0.59") or less
ductor diameter 80 (3.15") × 20 (0.79") mm busbar
Recording load current of 50Hz/60Hz
Recording leak current Primary current rating 1000 A AC 500 A AC 50 A AC
Features *Current and leak current that occur intermittently cannot be measured. Accuracy (45Hz to 66Hz) ±1.0% rdg. ±0.01% f.s. ±1.5% rdg. ±0.03% f.s. ±0.3% rdg. ±0.02% f.s.
The Clamp Logger LR5051 may be affected by high-frequency noise during leak
current measurement. Please contact Hioki for more information if you plan to Maximum rated voltage to earth CAT III 600 V rms CAT III 600 V rms CAT III 300 V rms
use the instrument in an environment where it would be affected by such noise. Maximum allowable input (45 to 66 Hz) 1000 A continuous 600 A continuous 60 A continuous
Measurement items AC Current (2 channels) 99.5 (3.92")W × 188 (7.40")H × 77 (3.03")W × 151 (5.94")H × 51 (2.01")W × 58 (2.28")H ×
When Using 9669 : 1000 A range Dimensions & mass
42 (1.65")D mm, 590 g (20.8 oz.) 42 (1.65")D mm, 360 g (12.7 oz.) 19 (0.75")D mm, 50 g (1.8 oz.)
When Using CT6500 : 50.00 A / 500.0 A range
Measurement When Using 9695-02 : 5.000 A / 50.00 A range
length
range When Using 9675 : 500.0 mA / 5.000 A range Connection Cord 9219(For 9695-02 connection)
: 3m(9.84ft)
Load current
When Using 9657-10 : 500.0 mA / 5.000 A range
3 m (9.84 ft) cord length 3 m (9.84 ft) cord length
Accuracy ±0.5% rdg. ±5dgt. + Clamp sensor accuracy Insulated
conductor
Insulated
conductor
Physical
Waterproof and dust- Not waterproof appearance
proof performance
Operating temperature -0˚C (32˚F) to 50˚C (122˚F) ,
Model CLAMP ON LEAK SENSOR 9675 CLAMP ON LEAK SENSOR 9657-10
and humidity 80% RH or less (non-condensating)
Measurable conductor diameter φ30 mm φ40 mm
Dimensions & mass Approx. 79 mm (3.11 in)W × 70 mm (2.76 in)H × 37 mm (1.46 in)D, 165 g(5.8 oz)
Primary current rating 5 A AC (Using with LR5051) 5 A AC (Using with LR5051)
Power supply LR6 (AA) Alkaline battery 1.5V × 2
Accuracy (45Hz to 66Hz) ±1.0% rdg. ±0.005% f.s. ±1.0% rdg. ±0.05% f.s.
LR6 (AA) Alkaline battery 1.5V × 2
Accessories Instruction manual ×1, Operation manual×1 Lag current 1 mA(When 10 A AC is input) 5 mA(When 100 A AC is input)
Measurable conductor Insulated conductor Insulated conductor
Case 1 : Approx. 1 years Case 2: Approx. 1 months
Maximum allowable input (45 to 66 Hz) 10A continuous 30A continuous
Battery life Case 1 : 1min. recording interval, power-saving mode, Instantaneous
recording, environmental temp.20˚C Case 2 : 1 sec. recording interval, 60 (2.36")W × 113 (4.45")H × 74 (2.91")W × 145 (5.71")H ×
Dimensions & mass
power-saving mode, Instantaneous recording, environmental temp.20˚C 24 (0.94")D mm, 160g (5.6 oz.) 42 (1.65")D mm, 380g (13.4 oz.)

Note: Company names and product names appearing in this brochure are trademarks or registered trademarks of various companies.

DISTRIBUTED BY

HEADQUARTERS
81 Koizumi,
Ueda, Nagano 386-1192 Japan
https://www.hioki.com/

All information correct as of Mar. 9, 2022. All specifications are subject to change without notice. series_LR5000E24-23B Printed in Japan

You might also like