CS3 Pulse Generator Guide

The CS3 pulse generator can control stepping motors and their speed from 0-1000 rpm. It has external controls for start/stop and direction. It has speed regulation and fixed length functions. The display shows speed in rpm during running and stop states. Parameters like acceleration, subdivision, run mode, length, delay, and times can be set. Running can be started from the panel or terminals. Speed is adjusted during operation via a potentiometer. Direction can be changed in stop state.

Uploaded by

maihung30gb
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
56 views3 pages

CS3 Pulse Generator Guide

The CS3 pulse generator can control stepping motors and their speed from 0-1000 rpm. It has external controls for start/stop and direction. It has speed regulation and fixed length functions. The display shows speed in rpm during running and stop states. Parameters like acceleration, subdivision, run mode, length, delay, and times can be set. Running can be started from the panel or terminals. Speed is adjusted during operation via a potentiometer. Direction can be changed in stop state.

Uploaded by

maihung30gb
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

CS3 pulse generator can control stepping motor, hefu motor, motor speed 0 0-1000 rpm, square wave,

stepless
adjustable. External start and stop, direction can be controlled externally. With speed regulation and fixed length
function.

Operating instructions

1. Display instructions: In the running state or the stop state, the digital tube displays the current speed value in
revolutions per minute. Display the set parameter code or parameter value in the setting state

2. Parameter setting: In the stop loading state, long press the stop button, ACC appears, and

then press the stop button to display the ACC parameter SET SET value, press the direction and

server keys to modify, After modifying, press stop to confirm, return to ACC state,

press direction key SET A to display tAb, press again to display Modo, then press to display

Model, press again to return to ACC parameter setting same as ACC, press offline key to exit A

parameter setting to stop state,

ACC acceleration setting (1-99) 1 is the fastest, 99 is the fastest, load reset is slower, the default value is 5

tAb subdivision setting (1-64) This value is set on the drive, and should be the same as the drive setting. When
consistent, the displayed speed is the actual speed, and the default value is 10.

When run (0-1) is set to 0, it will stop when it is powered on. When it is set to 1, it will run when it is powered on.
The default value is 0.

IN-S Run stop input is set to default value

0. Terminal 3 is turned on to start, and when it is turned off, it stops. The direction is terminal 4 is connected to
forward, and terminal 4 is turned off.

1 terminal 3 is clicked to start, and then clicked to stop, the direction is terminal 4 is pressed to stop

2 terminal 3 is pressed to start, terminal 4 is pressed to stop

3 Press terminal 3 to start forward, press again to stop, press terminal 4 to press reverse to start, press again to
stop

4 terminal 3 connects forward to start, disconnects to stop, terminal 4 connects to reverse to start , Disconnect
stop

Mode operation mode setting (0-3) 0 speed control, 1 fixed-length control, 2 continuous control, 3 reciprocating
control, the default value is 0 in fixed-length mode, stop state, press the stop button to set P-01, long Press the
stop button, there are d1A, d1b in continuous mode and round-trip mode, stop state press the stop button to set
P-01, P-02, P-03 in speed control mode and round-trip mode, X1X2 limit is valid, encounter will The direction is
reversed.

P-01 length value, number of pulses = P-01 * d1A / d1b doub: The default multiplication setting is 10-1000 rpm
adjustable

P-02 delay value, the unit is set to 20-2000 rpm adjustable

P-03 times value, The number of continuous running times is set to 30-3000 rpm, adjustable

3. Running instructions: Panel start or external terminal start, adjust the potentiometer to adjust the speed during
operation. When the panel stops or the external terminal stops, it displays 0 when it stops. If you need to display
the current adjusted speed of the potentiometer in the stop state, you can press it offline. When the offline light
is on, adjust the potentiometer to modify the speed value and change the direction in the stop state. Press the
panel Arrow keys or external arrow keys