0% found this document useful (0 votes)
52 views2 pages

6FM100/12Volt 100ah

This document provides specifications for a 6FM100/12Volt 100Ah lead-acid battery. The battery uses AGM technology, has a 10-year design life at 25°C, and is suitable for backup power systems, emergency power, and various equipment. Key specifications include a nominal voltage of 12V, rated capacity of 100Ah at the 10-hour rate, and dimensions of 331mm x 173mm x 213mm.

Uploaded by

Shadi Abu Sham'a
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
52 views2 pages

6FM100/12Volt 100ah

This document provides specifications for a 6FM100/12Volt 100Ah lead-acid battery. The battery uses AGM technology, has a 10-year design life at 25°C, and is suitable for backup power systems, emergency power, and various equipment. Key specifications include a nominal voltage of 12V, rated capacity of 100Ah at the 10-hour rate, and dimensions of 331mm x 173mm x 213mm.

Uploaded by

Shadi Abu Sham'a
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

6FM100/12Volt 100Ah

General Series VRLA batteries are designed with AGM(Absorbent


Glass Mat) technology,High performance plates and electrolyte togive
extra power output for common power backup system. General Series
Batteries are the general purpose batteries with 10 years floating design
life at 25℃.

Emergency Power System Power tools


Communication equipment Alarm system
Telecommunication systems Marine equipment
Uninterruptible power supplies Medical equipment
Electric toy car and wheelchairs, etc Fire and Security System

Heavy Duty Grid Positive........Lead dioxide Negative........Lead


Mechanized assembly Electrolyte........Sulfuric acid Safety Valve........EPDR
Non-spillable construction Separator........Fiber glass Terminal........Copper
High Reliability and Stability Container........ABS(UL94-HB) / Flame Retardant ABS (UL94-V0)
Sealed and Maintenance-free
Long Life and low self-discharge design

Nominal Voltage 12V

Battery Model Rated capacity (10Hour rate) 100Ah

Cells Per battery 6

Length Width Height Total Height


Dimension
331mm 173mm 213mm 218mm

Approx Weight 28.00Kg

Internal Resistance Full charged at 25℃(77℉): Approx 5mΩ

Max.discharge current 800A(5s)

Floating design life @ 25℃ (77℉) 10 years

10Hour rate(10A/10.8V) 5Hour rate(14.45A/10.5V) 3Hour rate(18.75A/10.5V) 1Hour rate(38.5A/10.5V)


Capacity @ 25℃ (77℉)
100Ah 72.25Ah 56.25Ah 38.5Ah

40℃ (104℉) 25℃ (77℉) 0℃ (32℉) -15℃(5℉)


Capacity affected by Temp(10 HR)
102% 100% 85% 65%

After 3 months storage After 6 months storage After 12 months storage


Self Discharge @ 25℃ (77℉)
93% 84% 65%

Cycle Use 14.5-14.9V (Initial charging current less than 30A)


Charge method @ 25℃ (77℉)
Float Use 13.6-13.8V
3

6FM100 12Volt 100Ah


8.5
218
213

18
9

20

Constant voltage charge (25℃)


-Cycle use: 14.50-14.90V
-Standby use: 13.60-13.80V
-Max. charge current: 30.00A

M6
331 173 17.5

F.V / TIME 5min 10min 15min 30min 1h 2h 3h 4h 5h 8h 10h 20h


A 360.00 220.00 175.00 115.00 60.00 35.00 26.00 21.00 17.54 11.58 11.00 5.70
9.60V
W 3816.00 2336.40 1872.50 1242.00 654.00 381.50 286.00 231.00 192.96 128.57 122.10 64.13

A 330.00 220.83 160.83 109.17 62.00 33.58 25.50 20.00 17.21 11.40 10.50 5.60
10.20V
W 3597.00 2451.25 1793.29 1228.13 697.50 379.49 288.15 227.00 195.31 129.39 119.18 63.56

A 306.04 211.00 150.00 105.83 60.00 32.92 25.00 19.00 17.00 11.25 10.30 5.53
10.50V
W 3366.46 2373.75 1695.00 1206.50 684.00 376.90 286.25 218.50 195.50 129.38 118.45 63.60

A 278.67 201.67 140.00 101.00 58.00 32.08 24.50 18.67 16.25 10.96 10.00 5.46
10.80V
W 3065.33 2299.00 1603.00 1166.55 669.90 370.56 284.20 217.47 189.31 127.66 116.50 63.61

A 241.00 190.00 130.00 94.00 55.00 31.25 23.50 18.33 15.54 10.67 9.75 5.40
11.10V
W 2723.30 2194.50 1508.00 1099.80 643.50 365.63 276.13 216.33 183.39 125.87 115.05 63.72

Note: The above datas are average values. (Edition 2017-11) www.championpower.cn
Page 1 of 2
6FM100/12Volt 100Ah

120

2.16/6.48/13.0 100
Voltage (V)

1.85/5.55/11.1 80
1.80/5.40/10.8

Capacity(%)
0.25C 0.20C 0.17C 0.12C 0.1C 60
1.75/5.25/10.5 100%DOD 50%DOD 30%DOD
0.05C
0.55C 0.40C
1.70/5.10/10.2 40
1.65/4.95/9.90
3C 2C 1C 20
1.60/4.80/9.60
0
7min 15min 27min 1h 2h 3h 4h 5h 8h 10h 20h 200 400 600 800 1000 1200 1400

Number of cycles (cycles)


Discharge time

Charged
( V / 12V )

Volume

Current

Voltage
( V / CE )
( V / 8V )

( V / 6V )

( V / 4V )

(%) (XCA) (V)


140
15.6 10.4 7.8 5.2 2.6
120 0.25
15.0 Charged Volume
15.0 10.0 7.5 5.0 2.5 Cyc 100
le U 0.20
se 14.0 Charge Voltage
14.4 9.6 7.2 4.8 2.4 80
0.15
13.0
Stand
by Use 60
13.8 9.2 6.9 4.6 2.3
0.10
40 12.0
13.2 8.8 6.6 4.4 2.2
20 0.05
11.0
Charging Current
-10 0 10 20 30 40 50 60 0 0
0 2 4 6 8 10 12 14 16 18 20
Ambient temperature(℃) Charging time (hours)

11 0

100
2.30V/Cell
5 90
Life (years)

Capacity (%)

80
1
70

60
40℃ 30℃ 20℃
50

0 40
10 20 30 40 50
0 2 4 6 8 10 12 14 16 18 20
Temperatura(℃) Storage time: months

120 15 7.5 5.0 120 0.24


Charge Volume

100 14 7.0 4.7 100 0.20


Charge Voltage
Charge Voltage (V)

Charge Currient (CA)

80 13 6.5 4.3 80 0.16


Charge Volume (%)

① Discharge
Capacity (%)

100% (0.05 CA*20h)


50% (0.05 CA*10h)
12 6.0 4.0 ② Charge 60 0.12
60 Charge Voltaje 2.275V /cell
Testing conditions: floating voltage: 2.27 to 2.30V /cell Charge Current 0.1 CA
③ Temperature 25℃
Ambient temperature: 25 ℃ (℉) 11 5.5 3.7 40 0.08
40

10 5.0 3.3 20 0.04


20 Charge Current

9 4.5 3.0 0 0
0 0 2 4 6 8 10 12 14 16 18 20 24 28
1 2 3
Charge Time (h)
Life (years)

Note: The above datas are average values. (Edition 2017-11) www.championpower.cn
Page 2 of 2

You might also like