0% found this document useful (0 votes)
126 views13 pages

Rohini 61347201776

The document provides details on designing a steel roof truss for a given span, type of truss, roof cover, and materials. It outlines the steps to: [1] Dimension the truss based on the given span; [2] Calculate dead, live, and wind loads; [3] Design the purlins and truss members to support the calculated loads. Design of the purlins and truss members involves checking the sections for shear capacity, moment capacity, and required strengths based on the applicable design standards.

Uploaded by

soumyadeba04
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
126 views13 pages

Rohini 61347201776

The document provides details on designing a steel roof truss for a given span, type of truss, roof cover, and materials. It outlines the steps to: [1] Dimension the truss based on the given span; [2] Calculate dead, live, and wind loads; [3] Design the purlins and truss members to support the calculated loads. Design of the purlins and truss members involves checking the sections for shear capacity, moment capacity, and required strengths based on the applicable design standards.

Uploaded by

soumyadeba04
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 13

ROHINI COLLEGE OF ENGINEERING & TECHNOLOGY

4.4 Code Provisions Design Of Steel Roof Truss

Example:5

Design a steel roof truss to suit the following data,

Span of the truss = 12m

Type of truss = pan type

Roof cover = Galvanization corrugated (GC) sheeting

Materials = Rolled steel angles

Spacing of roof truss = 5 m

Wind pressure =1KN/m^2

Draw the elevation of the roof truss and the details of joints.

Solution:

Step:1 Dimension of truss

Central rise = span/4

=12/4

= 3m

Purlins are provided at intervals of 1.863m on the principal rafter

Step:2 Dead loads

Self weight of GC sheeting per purlin at 0.18KN/m^2

= 0.18 x 1.863

= 0.335 KNm

Self weight of purlin at 0.1KN/m

= 0.10 KN/m

Total dead load = 0.435KN/m

CE8703 STRUCTURAL DESIGN AND DRAWING


ROHINI COLLEGE OF ENGINEERING & TECHNOLOGY

Step:3 Live loads

Slope of the truss = 26֯ 34`

Live load of the truss

= 0.75 – (10x0.01 + 6.5x0.02)

= 0.52 KN/m^2

Live load per purlin per metre

= 0.52x1.836xcos 26֯ 34`

= 0.87KN

Step:4 Wind loads

F = ( Cpe – Cpi )A pd

Cpe = external pressure coefficient

Cpi = internal pressure coefficient

A = Surface area of structural element or cladding unit

pd = design wind pressure

Slopping angle ,

Ө = 26֯ 34`

Cpe = -0.7

Cpi = 0.2

F = (-0.7 – 0.2)pd

= -0.9 pd

=-0.9x1

= -0.9 Kn/m^2

CE8703 STRUCTURAL DESIGN AND DRAWING


ROHINI COLLEGE OF ENGINEERING & TECHNOLOGY

Maximum wind load per purlin per metre

= (-0.9x1.863xcos26֯ 34`)

= 1.5 KN

Step:5 Design of purlin

For continuous purlin, the max factored bending moment and shear force
are computed as follow,

M = (1.5x1.305x5^2)/10

= 4.89 KNm

V = (1.5x1.305x5)/2

= 4.9 KN

Adopt ISA 100x75x8mm having section properties given below,

Zx = (4.38x10^4)mm^3

D = 100mm

b = 75mm

t = 8mm

IS 800:2007 clause 3.7,

(a) Check for section classification is done by computed the rations,

(b/t) =75/8

= 9.37<9.4

Hence the section considered as plastic .

(b) Check for shear capacity

Av = 100X8

= 800mm^2

CE8703 STRUCTURAL DESIGN AND DRAWING


ROHINI COLLEGE OF ENGINEERING & TECHNOLOGY

clause 8.4.1,

( Av fy w/√3 γmo) = (800x250)/(√3x1.10x10^3)

= 105 KN >4.9 KN

The shear capacity of the section is very large compared to the applied shear
force.

(c) Check for moment capacity

Md = (ẞb Zx fy )/γmo

= (1x4.38x10^4x250)/(1.1x10^6)

Md = 9.95 KNm > 4.89 KNm

Step:7 Load on truss

(a) Dead load

Slopping length of rafter,

AD = √(5^2+2.5^2)

= 5.59m

Spacing of trusses = 5m c/c

Weight of GC sheeting on half truss ( plan area ) at 0.18 KN/m^2

= 5x5x0.18

= 4.5 KN

Weight of purlins (4nos) at 0.10 KN/m

= 4x0.1x5

= 2 KN

CE8703 STRUCTURAL DESIGN AND DRAWING


ROHINI COLLEGE OF ENGINEERING & TECHNOLOGY

Self weight of roof truss = (span/300)+0.05

= (10/300)+0.05

= 0.083 KN/m^2

Weight of half roof truss = 0.083 x5 x5

= 2.075 KN

჻ Total load on half truss = 4.5+2+2.075

= 8.57 KN

Dead load on intermediate- panel point

= 8.57/3

= 2.85 KN

Dead load on end panel point

= 2.85/2

= 1.425 KN

(b) Live loads

Live load on half truss = 0.52 x5 x 5

= 13 KN

Live load on intermediate panel point

= 13/3

= 4.3 KN

Live load on end panel point

= 4.3/2

= 2.15KN

CE8703 STRUCTURAL DESIGN AND DRAWING


ROHINI COLLEGE OF ENGINEERING & TECHNOLOGY

© Wind loads

Maximum wind load acting perpendicular to the sloping surface

=- 0.9x5x5.59

= -25.155KN

Wind load on intermediate- panel point

= -(25.155/3)

= -8.38 KN

Wind load on end panel point

= -(8.38/2)

= 4.19 KN

Step:8 Design of truss members

(a) Members AB, BC, CD

Maximum service load compressive force

= 36.17 KN

Maximum factored compressive force

= 1.5x36.17

= 54.25 KN

Maximum service load tensile force

= 22.95 KN

Maximum factored tensile force

= 1.5x22.95

= 34.42 KN

Length (L) = 1.863m

CE8703 STRUCTURAL DESIGN AND DRAWING


ROHINI COLLEGE OF ENGINEERING & TECHNOLOGY

Effective length (KL) = 1.304m

Try two angle ISA 50x50x6mm placed back to back

Area (A) = 1136mm

Minimum radius of gyration

(γmin) = 15.1mm

Slenderness ratio = (KL/γmin)

= 1304/15.1

= 86.3 < 180

Stress reduction factor x for column buckling class (c) corresponding to the
slenderness

ratio 86.3 and fy = 250 N/mm^2

x = 0.56

჻Design compressive stress is computed as,

Fcd = x fy/γmo

=( 0.56x250)/1.25

= 112 N/mm^2

Design compressive force is given by,

Pd =[A fcd]

= (1136x112)/1000

= 127 KN > 54.25 KN

(b) Member DE

Maximum service load tension

= 12.83 KN

CE8703 STRUCTURAL DESIGN AND DRAWING


ROHINI COLLEGE OF ENGINEERING & TECHNOLOGY

Maximum factored load tension

= 1.5x12.83

= 19.24 KN

Maximum service load compression

= 9.57 KN

Maximum factored load compression

= 1.5x9.57

= 14.35 KN

Effective length = 3m

Try a single angle ISA 50x50x5mm connected by 6mm thick gusset plate the
junction with

two bolts of 16mm at 50mm.

Gross area (A) = 479mm^2

γmin = 15.2mm

Using 16mm dia bolts,

Anc = [50-18]5

=160mm^2

Ago = [50-5]5

= 225mm^2

Ag = 479mm^2

(a) Strength governed by rupture of critical section

Tdn = [0.9 Anc fy/γmi] + [ẞ Ago fy/γmo]

where, ẞ = 1.4 – 0.076(w/t)(fy/fu)(bs/Lc)

CE8703 STRUCTURAL DESIGN AND DRAWING


ROHINI COLLEGE OF ENGINEERING & TECHNOLOGY

= 1.4 – 0.076(50/5)(250/410)(50+25/50)

ẞ =0.70

Tdn = [0.9x160x410/1.25]+[0.7x225x250/1.10]x10^3

= 83.02 KN

= T₀

(b) Strength governed by yielding of gross section

Tdg = Ag fy / γmo

= (470x250x10^3)/1.10

= 108.8KN

(c) Strength governed by block shear

Avg = 5[50+50]

= 500mm^2

Avn = 5[50+50]- [1.5x18]

= 473mm^2

Atg = [5x25]

= 125mm^2

Atn = [(5x25)-(0.5x18)]

= 116mm^2

The block shear strength is the smaller of the value of Tdb1 and Tdb2 as
computed using

the equation given below,

Tdb1 = [Avg fy / √3γmo]+[0.9 Atn fu/γmi]

= [(500x250)/(√3x1.1) + (0.9x116x410)/1.25] x 10^-3

CE8703 STRUCTURAL DESIGN AND DRAWING


ROHINI COLLEGE OF ENGINEERING & TECHNOLOGY

= 99.92 KN

Tdb2 = [0.9 Avn fu/√3 γmi]+[Atg fy/γmo]

= [(0.9x473x410)/(√3x1.25) + (125x250)/1.10] x 10^3

= 109.12 KN

Hence, Tdb = 109.12 KN

The design shear strength is the least of the three value computed under (a)(b)(c) ,

which are 108.8 KN, 83.02KN, 109.12KN.

The design tensile strength of angle

= 83.02KN > 19.24 KN

(C) Member BC ,EB

Service load compressive force

= 6.95KN

Factored compressive force

= 1.5 X 6.95

= 10.42 KN

Service load tensile force

= 6.38 KN

Factored tensile force = 1.5x6.38

= 9.57KN

Effective length (kL) = 0.7x1.6

= 1.12m

Use minimum size angle ISA 50x50x5mm,

Area (A) = 479mm^2

CE8703 STRUCTURAL DESIGN AND DRAWING


ROHINI COLLEGE OF ENGINEERING & TECHNOLOGY

γmin = 9.7mm

Slenderness ratio ( λ) = 1120/9.7

= 115

The stress reduction factor x corresponding to

fy =250N/mm^2 and

λ = 115

x = 0.39

Design compressive stress is computed as,

fcd = x fy/γmo

= (0.39x250)/1.25

= 78 N/mm^2

Design compressive force is given by ,

Pd = A fcd

= [479x78]/1000

= 37.36KN > 10.42KN

(d) Member EA and EF

Max service load tension

= 32.21 KN

Factored tension = 1.5 x32.21

= 748.31 KN

Max service load compression

= 18.84 KN

CE8703 STRUCTURAL DESIGN AND DRAWING


ROHINI COLLEGE OF ENGINEERING & TECHNOLOGY

Factored compression

= 1.5x18.84

= 28.26 KN

Length of member = 3.33m

Effective length (kL) = 0.7x3.33

=2.331m

Try minimum two angle ISA 50x50x6mm connect by guesst plate 6mm thick

with two 16mm dia bolts spaced at 50mm

Area (A) = 2x598

= 113.6mm^2

γmin = 15.1mm

i) Design strength due to yielding of cross section ,

Tdj = Ag fy /γmo

=[ (1136+250)/1.10]x10^-3

= 258 KN

(d) Member EA and EF

Max service load tension

= 32.21 KN

Factored tension = 1.5 x32.21

= 748.31 KN

Max service load compression

= 18.84 KN

CE8703 STRUCTURAL DESIGN AND DRAWING


ROHINI COLLEGE OF ENGINEERING & TECHNOLOGY

Factored compression = 1.5x18.84

= 28.26 KN

Length of member = 3.33m

Effective length (kL) = 0.7x3.33

=2.331m

Try minimum two angle ISA 50x50x6mm connect by guesst plate 6mm thick

with two 16mm dia bolts spaced at 50mm

Area (A) = 2x598

= 113.6mm^2

γmin = 15.1mm

i) Design strength due to yielding of cross section ,

Tdj = Ag fy /γmo

=[ (1136+250)/1.10]x10^-3

= 258 KN

ii) Design strength governed by tearing at net section,

Tdn = α An fu/γmi

Assume a single line of 16mm dia bolts of two number spaced 50mm apart x=0.6

An = [(50-18)(6x2)]

= 384mm^2

Tdn = [(0.6x384x410)/1.25] x 10^-3

= 75.5KN > 48.31KN

Hence, the angle section designed for the truss can safely resist the factored loads.

CE8703 STRUCTURAL DESIGN AND DRAWING