0% found this document useful (0 votes)
31 views175 pages

B Ata 21

The document provides an overview of the air conditioning system on a Boeing 737-400 aircraft. It describes the key sub-systems that control the interior environment, including distribution, pressurization, equipment cooling, heating, cooling, and temperature control. It also lists important abbreviations and introduces the main components that control the functions of the air conditioning system, such as the pack/zone temperature controllers and cabin pressure controllers.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
31 views175 pages

B Ata 21

The document provides an overview of the air conditioning system on a Boeing 737-400 aircraft. It describes the key sub-systems that control the interior environment, including distribution, pressurization, equipment cooling, heating, cooling, and temperature control. It also lists important abbreviations and introduces the main components that control the functions of the air conditioning system, such as the pack/zone temperature controllers and cabin pressure controllers.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 175

CommAir Training

S C H O O L O F A E R O N A U T I C S

B 737-400

SISTEMAS Y PLANTA PODER


CURSO ATA NIVELIII-MANTENIMIENTO DE LINEA Y BASE

CAPITULOS ATA 21

CENTRO DE INSTRUCCIÓN DE MANTENIMIENTO


737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- INTRODUCTION
THIS PAGE INTENTIONALLY LEFT BLANK
21-00-00-801 Rev 1 01/12/2001

21-00-00
- 1 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- INTRODUCTION
Purpose

The air conditioning system controls the interior


environment of the airplane for flight crew,
passengers, and equipment.

Air Conditioning Sub-Systems

These are the air conditioning sub-systems:

- Distribution
- Pressurization
- Equipment cooling
- Heating
- Cooling
- Temperature control.

Abbreviations and Acronyms

A/C - air conditioning


ACAU - air conditioning accessory unit
C - Celsius
clng - cooling
CPC - cabin pressure controller
EE - electronic equipment
21-00-00-801 Rev 1 01/12/2001

F - Fahrenheit
PZC - pack/zone temperature controller
TCV - temperature control valve
FLT COMPT - flight compartment

21-00-00
- 2 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

AIR CONDITIONING

DISTRIBUTION EQUIPMENT COOLING HEATING COOLING


21-00-00-801 Rev 1 03/21/2001

PRESSURIZATION TEMPERATURE CONTROL

AIR CONDITIONING - INTRODUCTION

21-00-00
- 3 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- GENERAL DESCRIPTION
General Cabin Pressure Controller

These flight compartment panels let you control the air The cabin pressure controllers control the cabin
conditioning system: pressure function of the air conditioning system.

- Air conditioning/bleed air controls panel, P5-10


- Cabin temperature panel, P5-17
- Equipment cooling panel, P5
- Cabin pressure control panel, P5-6.

These components in the EE compartment control the


functions of the air conditioning system:

- Two pack/zone temperature controllers


- Two air conditioning accessory units (ACAU)
- Cabin pressure controllers (CPC).

Pack/Zone Temperature Controller

The pack/zone temperature controllers control these


functions of the air conditioning system:

- Pack cooling temperature


- Trim air, regulation, on or off
- Zone temperature.
21-00-00-803 Rev 1 10/12/1997

Air Conditioning Accessory Unit

The air conditioning accessory units are the interface


for the airplane operational logic and the air system.

21-00-00
- 4 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

AIR TEMP
PASS
FWD CAB
AFT
AFT
TEMP S
U D F
P U W C
P C D
L T P
Y CONT L A
CAB C
K

TRIM AIR
OFF
ON
ZONE ZONE ZONE
TEMP TEMP TEMP

CONT CABIN FWD CABIN AFT CABIN


AUTO AUTO AUTO

C W C W C W
OFF OFF OFF

CABIN TEMPERATURE
PANEL (P5)

DUAL
BLEED
RAM DOOR
FULL OPEN
RAM DOOR
FULL OPEN PACK/ZONE TEMPERATURE AIR CONDITIONING AIR CONDITIONING PACK
RECIRC FAN
OFF

AUTO
RECIRC FAN
OFF

AUTO
CONTROLLER (2) ACCESSORY UNIT (2)
OVHT

AIR
L PACK R PACK
TEST
TEMPERATURE
OFF
AUTO
HIGH
ISOLATION
VALVE
OFF
AUTO
HIGH
DATA
OPEN
TRIP

RESET
OFF OFF

ON ON
1 APU 2
BLEED
AUTO OFF SCHED
FAIL DESCENT ALTN MANUAL

AIR CONDITIONING/ AUTO MANUAL


BLEED AIR CONTROLS 0
1

PANEL (P5) EQUIP COOLING 10

0
ALT
HORN V
A
2
9
50
CABIN CUTOUT L
FLT ALT
SUPPLY EXHAUST
40 ALT
35
5 V
E
30
C
21-00-00-803 Rev 1 03/21/2001

NORM 8 X 1000 FEET 10


3
L O
25
O P
20 15
S E
4
E N
ALTN 7

5
6 ALTN
AUTO MAN
LAND ALT
PRESS DIFF
LIMIT: TAKE- 1 2
OFF & LDG .5
3
OFF OFF .125 PSI UP

a a 0 4

DN
3

EQUIPMENT COOLING .5 CAB ALT LAND ALT 2000 4000 6000 8000
2
1 FLT ALT
<FL160 FL220 FL260 FL320 FL410

PANEL (P5)
EE COOLING SYSTEM CABIN PRESSURE
CONTROL PANEL (P5)
AIR CONDITIONING - GENERAL DESCRIPTION

21-00-00
- 5 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- CONTROL PANELS
General - Pack reset.

These flight compartment panels on the P5 forward Equipment Cooling Panel


overhead panel let you control the air conditioning
subsystems: These controls and indications are on the equipment
cooling panel:
- Cabin temperature panel, P5-17
- Air conditioning/bleed air controls panel, P5-10 - Supply and exhaust fans switches
- Equipment cooling panel, P5 - No cooling indication.
- Cabin pressure control panel, P5-6
- Cabin altitude panel, P5-6. Cabin Pressure Control Panel

Cabin Temperature Panel These controls and indication are on the cabin pressure
control panel:
These controls and indications are on the cabin
temperature panel: - Landing altitude selector
- Flight altitude selector
- Control cabin temperature control - Mode selector
- Forward cabin temperature control - Outflow valve position indicator
- Aft cabin temperature control - Manual control toggle switch.
- Trim air switch
- Temperature indication and selection Cabin Altitude Panel
- Duct overheat indication.
These controls and indications are on the cabin
Air Conditioning/Bleed Air Controls Panel altitude panel:
21-00-00-802 Rev 1 04/22/1999

These controls and indications are on the air - Cabin altitude


conditioning/bleed air controls panel: - Cabin differential pressure
- Rate of change of cabin altitude
- Ram air inlet door indication - Altitude horn cutout switch.
- Recirculation fans switches
- Cooling pack switches
- Pack overheat and fault indication

21-00-00
- 6 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

AIR TEMP
CABIN PASS
CAB
TEMPERATURE 120
TEMP. 160
S
U
FWD
AFT
D AFT
P5 FORWARD PANEL 80 P
P
U F
200 C
L W R
OVERHEAD PANEL 40 Y
T
D P
A
F CONT L
CAB C
TRIM AIR K
OFF
ON

ZONE ZONE ZONE


TEMP TEMP TEMP

CONT CAB FWD CAB AFT CAB


AUTO AUTO AUTO

EQUIP COOLING C W C W C W
OFF OFF OFF

SUPPLY EXHAUST
DUAL
NORM BLEED
RAM DOOR
FULL OPEN
RAM DOOR
FULL OPEN

L RECIRC FAN R RECIRC FAN


ALTN OFF OFF
AUTO AUTO
AUTO OFF SCHED ALTN MANUAL
FAIL DESCENT
40 60
OVHT
AUTO MANUAL
OFF OFF 0
80
a a 10
1 PSI
ALT 0 100
0 HORN V TEST
50 2 CUTOUT A
EMER EXIT LIGHTS 9
35
40
CABIN
ALT 5 FLT ALT L
V
L PACK
OFF
ISOLATION
VALVE OFF
R PACK

30 E CLOSE
3 AUTO AUTO
EQUIPMENT COOLING 8
25
X 1000 FEET 10 C
L O HIGH AUTO HIGH
PANEL 20 15
4
O
S
P
E
7 E N WING WING
PACK OPEN PACK
ANTI TRIP OFF TRIP OFF ANTI
6 5 ICE ICE
21-00-00-802 Rev 1 03/21/2001

ALTN
AUTO MAN WING-BODY TRIP WING-BODY
LAND ALT OVERHEAT OVERHEAT
PRESS DIFF
LIMIT: TAKE- 1 BLEED BLEED
2 TRIP OFF TRIP OFF
OFF & LDG .5
.125 PSI 3
UP RESET
0 4 OFF OFF
DN
3 CAB ALT LAND ALT 2000 4000 6000 8000 ON ON
.5
1
2
FLT ALT 1 APU 2
<FL160 FL220 FL260 FL320 FL410 BLEED

CABIN ALTITUDE CABIN PRESSURE AIR CONDITIONING/BLEED


PANEL CONTROL PANEL AIR CONTROLS PANEL
AIR CONDITIONING - CONTROL PANELS

21-00-00
- 7 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COMPONENT LOCATION
Distribution Pressurization

The distribution system has these components in the The pressurization system has components in these areas
distribution compartment (aft of the forward cargo of the airplane:
compartment):
- Flight compartment
- Main distribution manifold - EE compartment
- Recirculation fans - Aft cargo compartment.
- Ground conditioned air connection.

The equipment cooling system has components in the EE


compartment, the forward equipment compartment, and the
flight compartment.

Cooling System

The two air conditioning packs are in the air


conditioning compartments. The air conditioning
compartments are on the left and right sides of the
keel beam in the wing-to-body area. Access is from the
bottom of the airplane fuselage.

Temperature Control

The temperature control system has components in these


areas of the airplane:
21-00-00-805 Rev 1 10/11/1997

- Passenger distribution ducting


- EE compartment
- Flight compartment.

21-00-00
- 8 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

PASSENGER
DISTRIBUTION

AIR
CONDITIONING
PACKS
CONTROLS AND
INDICATIONS
21-00-00-805 Rev 1 03/27/2001

(P5)

FLIGHT MAIN
COMPARTMENT DISTRIBUTION
DISTRIBUTION MANIFOLD
FORWARD EE COMPARTMENT
EQUIPMENT
COMPARTMENT
AIR CONDITIONING - COMPONENT LOCATION

21-00-00
- 9 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- FUNCTIONAL DESCRIPTION
THIS PAGE INTENTIONALLY LEFT BLANK
21-00-00-804 Rev 1 03/21/2001

21-00-00
- 10 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- FUNCTIONAL DESCRIPTION
General Usually, the left and right flow control systems
provide the same quantity of fresh air. Fresh air flow
These are the primary parts of the air conditioning changes when airplane conditions change.
(A/C) system that have an effect on the supply of fresh
air or the recirculation of conditioned air: Pack Cooling System

- Pack flow control This part of the A/C system removes water as necessary
- Pack cooling system and controls the temperature of the fresh air before it
- Zone temperature control flows into the air distribution part of the air
- Recirculation conditioning system. The primary components are the
- Air distribution. left and right packs.

The primary parts of the A/C system have these The usual control for the left pack makes sure that it
functions: supplies air at a temperature that gives the necessary
cooling for the flight compartment.
- Control fresh air flow for airplane pressurization
and ventilation The control for the right pack makes sure that it
- Control the flight compartment and passenger cabin supplies air at a temperature that gives the necessary
temperature cooling for the mix manifold.
- Recirculate cabin air for ventilation.
Zone Temperature Control
Pack Flow Control
This part of the A/C system increases the temperature
This part of the A/C system controls the quantity of of the conditioned air that flows into the occupied
fresh air that flows into the airplane. The control is areas of the airplane. It also gives pressure
by a flow control and shutoff valve. regulation and on/off control for the trim air part of
21-00-00-804 Rev 1 03/21/2001

the system. These are the primary components:


The quantity of fresh air necessary for ventilation is
more than for pressurization. The ventilation quantity - Trim air pressure regulating and shutoff valve
is based on a fixed value for the crew and allowable - Zone trim air modulating valves
leakage, and on the number of passenger seats. - Temperature sensors.

21-00-00
- 11 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- FUNCTIONAL DESCRIPTION
The system calculates the necessary pack outlet - Mix manifold
temperatures to satisfy the cooling needs to the flight - Distribution ducts/risers.
compartment and the mix manifold. The system also
calculates the heating necessary for each temperature
control zone. These are the temperature control zones:

- Flight compartment zone


- Passenger cabin zones (2).

Air from the pneumatic system adds heat to a zone that


needs warmer air. The trim air pressure regulating and
shutoff valve gives on/off control and keeps trim air
pressure at a necessary limit.

The zone trim air modulating valves control the heat


added to the conditioned air for each zone.

Recirculation

This part of the A/C system recycles approximately 50


percent of the cabin air for ventilation purposes. This
reduces the quantity of fresh air from the pneumatic
system for ventilation. The left and right
recirculation fans and filters are the primary
components.
21-00-00-804 Rev 1 03/21/2001

Air Distribution

This part of the A/C system moves conditioned air from


the packs or ground air source to the temperature
control zones. These are the primary components:

- Ground air connector

21-00-00
- 12 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

PRESSURE
BULKHEAD
RIGHT
RECIRCULATION RIGHT
SYSTEM COOLING
PACK

AFT
PASSENGER
ZONE

TRIM AIR AND


TEMPERATURE
CONTROL SYSTEM
FORWARD GROUND A/C
PASSENGER ZONE CONNECTOR

MIX
MANIFOLD
21-00-00-804 Rev 1 03/21/2001

EQUIPMENT
COOLING LEFT
COOLING
PACK

FLIGHT LEFT FLOW CONTROL


COMPARTMENT RECIRCULATION AND SHUTOFF
ZONE SYSTEM VALVE (2)

AIR CONDITIONING - FUNCTIONAL DESCRIPTION

21-00-00
- 13 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- PACK/ZONE TEMPERATURE CONTROLLER - BITE
THIS PAGE INTENTIONALLY LEFT BLANK
21-00-00-806 Rev 1 06/29/1999

21-00-00
- 14 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- PACK/ZONE TEMPERATURE CONTROLLER - BITE
Purpose BITE Test Switches

The pack/zone temperature controllers have front face The pack/zone temperature controller has these
BITE that isolates system faults to the LRU interface switches:
level.
- PRESS/TEST
General Description - BIT
- PREV FLT
The BITE circuitry can detect failures of these - VERIFY
components: - RESET.

- Pack/Zone controller The PRESS/TEST switch does a test of the 25 indicator


- Ram air controller lamps. This monitors power and indication availability.
- Pack standby controller
- Zone temperature selector The BIT test switch starts a system self-test. The BIT
- Cabin temperature sensor switch shows failures that occurred during the last
- Duct temperature sensor flight.
- Zone trim air modulating valves
- Ram air control temperature sensor A flight starts when the air mode is sensed for longer
- Ram air inlet actuator than 30 seconds.
- Standby pack temperature sensor
- Standby pack temperature control valve (TCV) The PREV FLT test switch starts a system self-test. The
- Mix manifold temperature sensor PREV FLT switch shows all the failures that occurred
- Pack temperature sensor during the last nine flights.
- Pack temperature control valve (TCV).
The VERIFY test switch starts a system self-test.
21-00-00-806 Rev 1 06/29/1999

The pack/zone temperature controller has one register


for last flight memory storage. WARNING: MOVE ALL PERSONS AND EQUIPMENT AWAY FROM THE
RAM AIR INLET DOOR. WHEN YOU PUSH THE VERIFY
The pack/zone temperature controller has nine registers SWITCH, THE RAM AIR COMPONENTS WILL MOVE AND
for previous flight history memory storage. CAN CAUSE INJURY TO PERSONS OR DAMAGE TO
EQUIPMENT.

21-00-00
- 15 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- PACK/ZONE TEMPERATURE CONTROLLER - BITE
The VERFIY switch starts a real time test of the pack
and zone temperature control components.

The RESET test switch is used to erase the fault


history. Push the RESET switch while the VERFIY and the
green GO lights are on.

BITE Indications

The pack/zone temperature controller has a red lamp for


each of the LRUs.

The pack/zone temperature controller has a green lamp


to show no faults are in the system.

The pack/zone temperature controller has four amber


lamps to show the test in progress.
21-00-00-806 Rev 1 06/29/1999

21-00-00
- 16 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

BITE INSTRUCTION
1 IF CONTROLLER FAULT LAMP ON REPLACE IF RED,REPLACE UNIT INDICATED AND PRESS
CONTROLLER VERIFY IF ANY FLT DECK OR ZONE RED LAMP ON
2 AT FLIGHT DECK IDENTIFY AS FOLLOWS
Ñ ALL BLEED SWITCHES OFF LAMP
____ LH CONT
_______ RH CONT
_______
Ñ ZONE TEMP SELECTORS AUTO
Ñ LH AND RH PACK SWITCHES AUTO FLT DECK BACKUP PRIMARY
Ñ TRIM AIR SWITCH ON ZONE AFT ZONE FWD ZONE PRESS/
BKUP ZONE FWD ZONE AFT ZONE
TEST
BIT TEST SWITCHES
3 ON BOTH CONTROLLERS
Ñ LAMP TEST-PUSH PRESS/TEXT. IF ANY LAMP
DOES NOT ILLUMINATE REPLACE Ñ WHEN VERIFY GREEN
CONTROLLER
Ñ PRESS ALL 3 TEST SWITCHES IN SEQUENCE
INDICATED AT EACH POSITION WAIT FOR
4
PRESS RESET
AT FLIGHT DECK LH AND RH AND INDICATORS
PACK SWITCHES OFF
GREEN OR RED LAMP ON

PACK/ RAM STANDBY


ZONE AIR PACK BIT PREV FLT VERIFY RESET
CONTROLLER
FAULT GO

CABIN DUCT TRIM


SELECTOR VALVE
SENSOR SENSOR

FLT FLT
DECK
DECK OPERATES ONLY
CONTROL WHILE VERIFY
ZONE ZONE SELF-CHECK ON

BKUP
ZONE

RAM AIR STANDBY

MIX MANF
SNSR SENSOR
PACK LAST FLIGHT ACTIVE CLEARS ALL
SNSR MEMORY READOUT PRESENT FAULT NON-VOLATILE
ACT
PACK 1-REGISTER TEST OF ALL LRUS MEMORY REGISTERS
TCV SNSR TCV
OTHER PACK THIS PACK

BIT PREV FLT VERIFY RESET


21-00-00-806 Rev 1 12/13/1999

PREVIOUS FLIGHTS RESTARTS CONTROL


MEMORY READOUT AND CONTINUOUS
TEST SWITCHES 9-REGISTER BITE OPERATION

AIR CONDITIONING - PACK/ZONE TEMPERATURE CONTROLLER - BITE

21-00-00
- 17 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - INTRODUCTION
Purpose

These are functions of the cooling system:

- Control the quantity of air from the pneumatic


system to the pack
- Remove heat from the air that enters the pack
- Control the output temperature and moisture of the
pack.

Abbreviations and Acronyms

A/C - air conditioning


ACM - air cycle machine
ACAU - air conditioning accessory unit
APU - auxiliary power unit
C - celsius
F - fahrenheit
FCSOV - flow control and shutoff valve
FMCS - flight management computer system
gnd - ground
HPWS - high pressure water separator
OVHT - overheat
sw - switch
21-50-00-801 Rev 1 10/07/1997

vlv - valve

21-50-00
- 18 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

LEFT RIGHT
TEMPERATURE TEMPERATURE
CONTROL (REF) CONTROL (REF)

LEFT PACK RIGHT PACK


21-50-00-801 Rev 1 06/09/2001

PNEUMATIC LEFT PACK COOLING DISTRIBUTION COOLING RIGHT PACK PNEUMATIC


SYSTEM FLOW CONTROL TEMPERATURE (REF) TEMPERATURE FLOW CONTROL SYSTEM
CONTROL CONTROL

AIR CONDITIONING - COOLING - INTRODUCTION

21-50-00
- 19 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - GENERAL DESCRIPTION
THIS PAGE INTENTIONALLY LEFT BLANK
21-50-00-802 Rev 1 09/29/2000

21-50-00
- 20 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - GENERAL DESCRIPTION
General Primary Heat Exchanger

The cooling system uses these components and systems to The primary heat exchanger receives bleed air from the
cool the bleed air: flow control and shutoff valve. As the bleed air goes
through the heat exchanger, ram air removes heat. The
- Air conditioning/bleed air controls panel cooled bleed air goes to the compressor section of the
- Flow control and shutoff valve air cycle machine.
- Heat exchangers (2)
- Air cycle machine Air Cycle Machine
- Reheater
- Condenser The air cycle machine is a two wheel, oil lubricated
- Ram air system air cycle machine.
- Water extraction.
Cooled bleed air from the primary heat exchanger enters
Air Conditioning/Bleed Air Controls Panel the air cycle machine where it is compressed. The
compressed air then goes to a secondary heat exchanger,
The air conditioning/bleed air controls panel gives a water separator system and then back to the air cycle
control and indications of the cooling system. These machine where the bleed air is rapidly expanded and
are the controls and indications of the cooling system: sent to a condenser.

- RAM DOOR FULL OPEN lights Secondary Heat Exchanger


- L/R PACK switches
- PACK lights The secondary heat exchanger receives compressed air
- TRIP RESET button. from the air cycle machine. As the air goes through the
heat exchanger, ram air removes heat. After the
Flow Control and Shutoff Valve compressed air is cooled it goes through a water
21-50-00-802 Rev 1 09/29/2000

extractor duct and back to the air cycle machine.


Bleed air from the pneumatic system supplies bleed air
to the flow control and shutoff valve. The valve Reheater
controls the flow of bleed air into the pack. After the
bleed air goes through the flow control and shutoff The reheater increases the temperature of the air in
valve it enters the primary heat exchanger. the air conditioning pack before it enters the turbine
of the air cycle machine.

21-50-00
- 21 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - GENERAL DESCRIPTION
Condenser

The condenser decreases the temperature of the air in


the air conditioning pack to below the dew point,
changing water vapor into liquid.

Ram Air System

The ram air system controls the quantity of outside


ambient air that flows through the heat exchangers.

On the ground and in flight with the flaps not up, the
turbofan helps the cooling airflow through the ram air
system.

Water Extraction

The water extraction collects and removes moisture from


the air before it goes into the distribution system.
21-50-00-802 Rev 1 09/29/2000

21-50-00
- 22 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

b b
DUAL RAM DOOR RAM DOOR
BLEED a FULL OPEN FULL OPEN

L RECIRC FAN R RECIRC FAN


OFF OFF

AUTO AUTO
PNEUMATIC
40 60
MANIFOLD (REF)
OVHT
80
PSI
0 100
TEST
L PACK R PACK FLOW CONTROL
ISOLATION AND SHUTOFF VALVE
OFF VALVE OFF
AUTO AUTO
HIGH AUTO HIGH

CONDENSER AIR MIX


OPEN VALVE
PACK PACK
a a
REHEATER
WING-BODY TRIP WING-BODY
OVERHEATa OVERHEATa AIR CYCLE MACHINE
a a
BLEED BLEED
TRIP OFF TRIP OFF
RESET
OFF OFF
21-50-00-802 Rev 1 09/29/2000

ON ON HEAT EXCHANGERS
1 APU 2
BLEED
RAM AIR SYSTEM
AIR CONDITIONING/BLEED AIR
CONTROLS PANEL (P5)

AIR CONDITIONING - COOLING - GENERAL DESCRIPTION

21-50-00
- 23 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - COMPONENT LOCATION
Component Locations

The air conditioning cooling system components are in


these areas of the airplane:

- Flight compartment
- EE compartment
- Distribution compartment
- Air conditioning compartment and wing-to-body
fairing.

Flight Compartment

The air conditioning/bleed air controls panel is on the


P5 overhead panel.

EE Compartment

The air conditioning accessory units (ACAUs) are on the


E3-2 shelf.

Distribution Compartment

The mix manifold temperature sensors and pack discharge


overheat switches are in the distribution compartment.
21-50-00-804 Rev 1 09/19/2000

Air Conditioning Compartment and Wing-to-Body Fairing

The air conditioning pack systems are in the air


conditioning compartments. The ram air system is in the
wing-to-body fairing. This is the area forward and
outboard of the air conditioning compartment.

21-50-00
- 24 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

AIR CONDITIONING/
BLEED AIR
CONTROLS PANEL

AIR
RAM AIR CONDITIONING
SYSTEM PACKS

FLIGHT COMPARTMENT

MIX MANIFOLD PACK DISCHARGE


TEMP SENSORS OVHT SWITCHES
PACK/ZONE
CONTROLLERS (REF) ACAU (2)

FWD
AIR CONDITIONING COMPARTMENT
AND WING-TO-BODY FAIRING
21-50-00-804 Rev 1 09/19/2000

FWD

FWD
DISTRIBUTION COMPARTMENT EE COMPARTMENT

AIR CONDITIONING - COOLING - COMPONENT LOCATION

21-50-00
- 25 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - AIR CONDITIONING ACCESSORY UNITS
Purpose - Engine bleed switches
- Duct overheat switches
The air conditioning accessory unit (ACAU) is the - Pneumatic system valves
interface of the airplane operational logic and the air - Air conditioning/bleed air controls panel
systems. - Cabin temperature panel
- Pressurization outflow valve
Location - Recirculation fans
- Forward outflow valve
The ACAUs are in the EE compartment on the E3-2 shelf. - Pneumatic system ovht/ovpress switches
- FMC.
Interfaces
The ACAU sends signals to these components:
The air conditioning accessory unit has an interface
with these systems: - Air conditioning/bleed air controls panel
- Cabin temperature panel
- Flight controls (flaps not up switch) - Bleed air regulators
- Landing gear (air/ground) - Engine start valves
- Engine starting - Pack flow control and shutoff valves
- Air conditioning - Ram air actuators
- Pneumatic/bleed air - Outflow valve
- Flight management computer (FMC). - Recirculation fans
- EE cooling fans
The ACAU receives signals from these airplane - FMC.
components:
Training Information Point
- Engine start valves
21-50-00-809 Rev 1 03/26/2001

- Flap control unit You must do an adjustment/test after you replace the
- Flap up switch ACAU.
- Air/Gnd relays
- Pack flow control and shutoff valve
- Ram air actuators
- Pack overheat switches
- Pack/Zone temperature controller

21-50-00
- 26 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
21-50-00-809 Rev 1 01/21/1999

AIR CONDITIONING - COOLING - AIR CONDITIONING ACCESSORY UNITS

21-50-00
- 27 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - FLOW CONTROL AND SHUTOFF VALVE - MECHANICAL FUNCTIONAL
Functional Description to maintain the desired flow rate as cabin pressure
decreases. Normal flow mode has an airflow rate of 75
The flow control and shutoff valve is electrically pounds per minute (ppm).
controlled and pneumatically actuated. It is spring-
loaded to the closed position. The valve operates by a When the pack switch is in the HIGH position, solenoid
pneumatic actuator which moves a butterfly plate. When B de-energizes (high flow mode). Actuator air flows to
the pack switch is in the OFF position, 28v dc the APU/high flow servo. The high flow servo has a
energizes solenoid C to the close position. This moves strong bias to close. This will let more air pressure
a ball valve that prevents air pressure from going to go to the valve actuator. This increases airflow. High
the actuator to open the valve. flow mode is 105 ppm.

When the pack switch is in the AUTO or HIGH position, In cruise, if a pack shuts down from an overheat or if
solenoid C receives power to the open coils. The a (L or R) pack switch is OFF, solenoid B de-energizes.
pressurized air flows to the actuator. It pushes This sets the operating pack to high flow mode.
against spring force in the actuator to open the
butterfly plate (valve open). When the valve opens, air The APU high flow mode energizes solenoid A. The APU
flows to the static pressure sense port and the /high flow servo has one more actuating piston than
downstream (total pressure) sense port. high flow. This results in a higher spring-bias to
close the servo. This lets more pressure go to the
The static and total pressure sense ports balance valve actuator. APU/high flow mode has an airflow rate
actuator opening pressure for the auto and high flow of 131 ppm.
servos. These ports permit a measure of differential
pressure in the venturi which corresponds to the rate Training Information Point
of airflow.
A manual control shaft on solenoid C lets you open the
Solenoid B changes flow modes between the normal flow solenoid manually.
21-50-00-807 Rev 1 01/21/1999

and the high flow modes. It energizes when the pack


switch is in the AUTO position. This lets air flow to The flow control and shutoff valve cabin pressure sense
the auto flow servo (normal flow mode). The auto flow port is connected by a sense line to an open port in the
servo controls flow rate as cabin air pressure changes. distribution bay. This port must be clean for the flow
The cabin pressure sense port provides a cabin air control and shutoff valve to properly control airflow.
pressure signal to the auto flow servo internal
bellows. This allows the flow control and shutoff valve

21-50-00
- 28 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

APU/HIGH
FLOW SERVO AUTO
FLOW
SERVO

SOLENOID A

MANUAL CABIN
CONTROL PRESSURE
SHAFT SENSE PORT
SOLENOID B
SOLENOID C
INTERNAL
BELLOWS
PILOT
PRESSURE
REGULATOR
ACTUATOR

CLOSE
UPSTREAM
SENSE PORT
AIR STATIC PRESSURE TOTAL PRESSURE
FLOW
21-50-00-807 Rev 1 01/21/1999

SENSE PORT SENSE PORT

CLOSED BUTTERFLY VENTURI


POSITION PLATE
SWITCH

AIR CONDITIONING - COOLING - FLOW CONTROL AND SHUTOFF VALVE - MECHANICAL FUNCTIONAL DESCRIPTION

21-50-00
- 29 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - FLOW CONTROL AND SHUTOFF VALVE - ELECTRICAL FUNCTIONAL
Pack Switch OFF - Airplane in the air (the pack air/gnd relay (K10)
goes to the AIR position)
When the pack switch is in the OFF position, 28v dc - Flaps up (the flap not up relay (K19) goes to the
(battery bus) energizes the close coil of solenoid C. UP position).
When the close coil is energized, the flow control and
shutoff valve is closed. When solenoid B deenergizes, the FCSOV operates in the
high flow mode.
Pack Switch AUTO
Pack Switch HIGH
When the pack switch is in the AUTO position, 28v dc
energizes the open coil of solenoid C. When open coil When the switch is in the HIGH position, solenoid B is
of solenoid C is energized, the FCSOV opens. This also deenergized. When solenoid B is deenergized, the FCSOV
moves a position switch to open. The position switch is in the high flow mode.
gives a discrete signal to these systems:
Solenoid A is energized when the all of these
- Flight management computer system conditions are true:
- Pressurization system
- Temperature control system - The pack switch is in the HIGH position
- Recirculation system. - The APU bleed switch is in the ON position
- The APU operates above 95%
When either engine bleed switch is on, 28v dc energizes - The airplane is on the ground.
solenoid B through the low flow mode relay (K18).
When solenoid A is energized the FCSOV operates in the
When solenoid B is energized, the FCSOV operates in the APU high flow mode.
low flow mode.
21-50-00-811 Rev 1 03/26/2001

Solenoid B deenergizes when K18 energizes. K18


energizes when both engine bleed switches are in the
OFF position.

Also, solenoid B deenergizes when these things occur:

21-50-00
- 30 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

1
28V DC
BAT BUS
A/C PACK CONT
VALVE RIGHT
CLOSED
28V DC OVHT CLOSE
BAT BUS
A/C PACK CONT C
VALVE LEFT
K8 PACK OPEN
P6 CB PANEL
OFF OVHT RLY
LOW FLOW
AUTO MODE
HIGH B

K18 FLOW APU HIGH


MODE RLY FLOW MODE

UP AIR A
AIR
28V DC
L FCSOV
NOT UP GND
95% GND
L PACK SW K19 FLAP K10 PACK
APU CONTROL R275 GND NOT UP AIR/GND
UNIT SENSE RLY OFF OFF RLY RLY
(E11)
ON
ON
ENG BLEED SW L ACAU 1
21-50-00-811 Rev 1 03/26/2001

OFF CLOSED
NOTE: RIGHT PACK FCSOV R FCSOV
CIRCUIT SIMILAR ON
1 PROVIDES A DISCRETE TO APU BLEED
THE FMCS, RECIRC, SW
PRESSURIZATION AND AIR COND/BLEED AIR
TEMP CONTROL SYSTEMS CONTROLS PANEL (P5)
AIR CONDITIONING - COOLING - FLOW CONTROL AND SHUTOFF VALVE - ELECTRICAL FUNCTIONAL DESCRIPTION

21-50-00
- 31 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - HEAT EXCHANGERS
Purpose Training Information Point

The primary heat exchanger (HX) removes heat from bleed The heat exchanger efficiency decreases as dirt and
air going to the compressor section of the air cycle contamination collect on the cooling surfaces. A RAM
machine (ACM). DOOR FULL OPEN light that stays on in flight can be an
indication of a dirty heat exchanger.
The secondary heat exchanger (HX) removes heat from
bleed air that comes from the compressor section of the
air cycle machine (ACM).

Location

The primary and secondary heat exchangers are in the


aft outboard sections of each air conditioning
compartment.

Physical Description

The heat exchangers are air-to-air, plate-fin, counter-


flow type. Two isolated airstreams flow through thin
walled channels. The channel walls are made up of
plates and fins that increase surface area.

Functional Description

Air from the FCSOV flows through the primary heat


21-50-00-815 Rev 1 01/21/1999

exchanger. Across flow of ram air removes heat before


the air enters the ACM compressor inlet.

Air from the ACM compressor outlet flows through the


secondary heat exchanger. A cross flow of ram air
removes heat before the air enters the ACM turbine
inlet.

21-50-00
- 32 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

SUPPORT
ROD

HEAT EXCHANGER
INLET

FWD

TO ACM

AIR CONDITIONING COMPARTMENTS


SECONDARY
HEAT EXCHANGER
21-50-00-815 Rev 1 01/21/1999

RAM AIR OUTLET DUCT

PRIMARY
HEAT EXCHANGER

AIR CONDITIONING - COOLING - HEAT EXCHANGERS

21-50-00
- 33 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - RAM AIR DUCTS
Purpose ram air inlet duct through the fairing panels. They are
outboard of the air conditioning doors.
The ram air inlet ducts let cooling air flow from the
ram air inlet to the heat exchangers. The ram air A special tool lets you clean the heat exchangers when
exhaust ducts let air flow from the heat exchangers they are dirty.
discharge overboard.
You can repair the ducts if they have cracks or leaks.
Location

The ram air inlet ducts are outboard of the air


conditioning compartment. They extend forward to the
ram air inlet in the wing-to-body fairing.

The ram air exhaust ducts are aft of the air


conditioning compartments. You get access to the
exhaust ducts from the air conditioning compartment.

Physical Description

The ram air inlet ducts are made of fiberglass


reinforced polymer. The forward section of the inlet
ducts attach to the airplane structure at the forward
part of the ram air inlet. The ram air exhaust ducts
attach to the aft end of the heat exchangers ducting.

Training Information Point


21-50-00-810 Rev 1 03/26/2001

There is a heat exchanger inlet inspection/clean-out


panel in the inlet ducts. This permits access to the
primary and secondary heat exchanger inlets. The access
panel is in the lower area of the duct, adjacent and
outboard of the heat exchangers. You get access to the

21-50-00
- 34 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

RAM AIR
INLET

RAM AIR
INLET DUCT

WING-TO-BODY
FAIRING

ACCESS
PANEL

RAM AIR
EXHAUST DUCT
21-50-00-810 Rev 1 03/26/2001

FWD

RAM AIR
EXIT
LOUVERS
AIR CONDITIONING COMPARTMENT

AIR CONDITIONING - COOLING - RAM AIR DUCTS

21-50-00
- 35 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - RAM AIR ACTUATOR
Purpose receives control signals from the pack/zone temperature
controller.
The ram air actuator moves the ram air inlet deflector
door and the ram air inlet modulation panel. Functional Description

Location The control signals for the actuator go through the


internal limit switches. The internal limit switches
The ram air actuator is in the aft section of the air sequence the order of control signals to the motor. The
conditioning compartment. The actuator attaches to the motor turns a linear jackscrew. The jackscrew moves the
structure near the ram air exhaust assembly. You get ram air inlet modulation panel and deflector door
access to the actuator from the air conditioning through mechanical linkages.
compartment. There is a ram air actuator for the left
and the right ram air systems.

Physical Description

The ram air actuator is a 115v ac motor-operated linear


actuator. It has these parts:

- Motor
- Limit switches
- Jackscrew
- Electrical connection.

Interfaces
21-50-00-816 Rev 1 03/26/2001

The ram air actuator receives signals from the air


conditioning accessory unit (ACAU) and the pack/zone
temperature controller. The ACAU interface signals come
from the air ground sensing system and the flap control
unit. The ACAU logic controls the actuator when the
airplane is on the ground and in-flight when the flaps
are not up. In flight with the flaps up, the actuator

21-50-00
- 36 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

MOTOR

ELECTRICAL
CONNECTION

JACKSCREW
RAM AIR
INLET
LIMIT
SWITCHES

RAM AIR ACTUATOR


21-50-00-816 Rev 1 03/26/2001

AIR CONDITIONING COMPARTMENT


AIR CONDITIONING - COOLING - RAM AIR ACTUATOR

21-50-00
- 37 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - RAM AIR INLET DOOR ASSEMBLY
Purpose tube with two tie-rods and a preloaded spring. The tie-
rods connect to clevis fittings on the deflector door.
The ram air inlet assembly controls airflow into the
ram air system for heat exchanger cooling. The ram air inlet deflector door makes sure ice, rocks,
and other unwanted material do not go into the ram air
Location inlet.

The ram air inlet assembly is in the wing-to-body The shaft assembly moves the deflector door.
fairing forward of the air conditioning compartments.
Functional Description
Physical Description
The ram air actuator moves the modulation panel. Linear
The ram air inlet assembly has these two major movement of the actuator arm transmits movement through
assemblies: a link arm to the modulation panel shaft assembly. The
shaft turns link arms that lift or lower the two
- Ram air inlet modulation panel panels. The aft panel has rollers that let it move
- Ram air inlet deflector door. forward or aft as the two panels move up or down. The
modulation panel and the ram air inlet deflector door
Ram Air Inlet Modulation Panel are mechanically connected.

The ram air inlet modulation panel is made of two panel The ram air inlet deflector door has two positions.
sections. The two panels are hinged together. The When the airplane is on the ground, the door extends to
forward panel has a hinge at the forward end that give protection to the ram air inlet. When the airplane
connects to the airplane structure. The aft panel has is in the air, the deflector door retracts.
rollers in tracks at the aft end. On the aft panel,
clevis fittings on the mid section and the upper The ram air actuator transmits motion through tie-rods
21-50-00-817 Rev 1 02/14/1999

surface connect link arms to the shaft assembly. and link arms to the shaft assembly. The shaft assembly
transmits motion to the deflector door.
Ram Air Inlet Deflector Door

The ram air inlet deflector door is a flat surface that


is spring-loaded closed. The shaft assembly is a torque

21-50-00
- 38 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

FORWARD PANEL
DEFLECTOR
ROLLER BULB SEAL
ARM AFT PANEL

TRACK

FAIRING
PANEL

FWD
21-50-00-817 Rev 1 03/27/2001

INLET MODULATION
PANEL QUADRANT
RIGGING PIN
CABLES FROM
RAM AIR
RAM AIR INLET ACTUATOR

AIR CONDITIONING - COOLING - RAM AIR INLET DOOR ASSEMBLY

21-50-00
- 39 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - RAM AIR EXHAUST MODULATION LOUVER ASSEMBLY
Purpose

The ram air exhaust exit assembly controls airflow


through the ram air system during flight.

Physical Description

The ram air exhaust consists of three louvers at each


ram air exit. The louvers are parallel to each other
and are supported at either end by a support angle. The
arms have splines to mate with the outboard end of each
louver and are linked together at the other end of the
arm. This makes sure there is simultaneous movement of
all louvers.

The forward arm mates with a torque shaft that extends


from the arm to the ram air actuator. As the actuator
moves, the louvers turn to decrease or increase the
exhaust area. Because the torque shaft is connected to
the crank that operates the ram air inlet modulation
panel control cables, movement of the exit louvers and
the inlet modulation panel is at the same time.
21-50-00-829 Rev 1 02/14/1999

21-50-00
- 40 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

EXHAUST
AIR FLOW

LINKAGE

TORQUE SHAFT
INPUT
21-50-00-829 Rev 1 01/26/1999

FWD

RAM AIR EXHAUST LOUVERS

AIR CONDITIONING - COOLING - RAM AIR EXHAUST MODULATION LOUVER ASSEMBLY

21-50-00
- 41 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - RAM AIR SYSTEM - MECHANICAL FUNCTIONAL DESCRIPTION
Functional Description

The ram air inlet modulation panels are made of two


panel sections. The forward end of the forward panel is
hinged to structure and its aft end is hinged to the
forward end of the aft panel section. The aft end of
the aft panel section has rollers in tracks that allow
movement forward and aft. Two cranks with rollers move
the forward end of the aft panel inboard or outboard to
open or close the inlet. The cranks attach to a shaft
which is operated by the ram air actuator through a
cable system.

The deflector door is hinged at its forward edge to


airplane structure and is flush in the inlet when
retracted. This prevents interference with ram airflow
into the ram air ducts. A mechanical linkage connected
to the modulation panel cable system causes the
deflector door to be extended when the airplane is on
the ground. The deflector door helps prevent foreign
material from the ram air system when the airplane is
on the ground.
21-50-00-837 Rev 1 01/26/1999

21-50-00
- 42 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

RAM AIR
EXHAUST

FWD
RAM AIR TORQUE
INLET SHAFT
CONTROL
CABLES
RAM AIR
ACTUATOR
TORQUE
SHAFT
QUADRANT
FWD
AFT
FWD PANEL
CRANK
PANEL

ROLLER
CONTROL
DEFLECTOR CABLES
EXTENSION ARM ASSEMBLY
LINK

RAM AIR INLET - DEFLECTOR EXTENDED, DOOR OPEN


21-50-00-837 Rev 1 01/26/1999

CONTROL
CABLES

RAM AIR INLET - DEFLECTOR RETRACTED, DOOR CLOSED


AIR CONDITIONING - COOLING - RAM AIR SYSTEM - MECHANICAL FUNCTIONAL DESCRIPTION

21-50-00
- 43 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - RAM AIR TEMPERATURE SENSOR
Purpose

The ram air sensor supplies temperature data to the


pack/zone temperature controller.

Location

The ram air sensor is in the air conditioning


compartment. It is in the duct that connects the
compressor section of the ACM to the secondary heat
exchanger.

There is a ram air sensor for each pack ram air system.

Physical Description

The ram air sensor has a stainless steel probe housing.


The probe housing attaches to the electrical connector
and is hermetically sealed.

Functional Description

The ram air sensor is a thermistor bead element. The


resistance of the temperature sensing element changes
as the air temperature changes.
21-50-00-830 Rev 1 02/14/1999

The pack/zone temperature controller uses the


resistance of the temperature sensor in a control
bridge. When the temperature is more or less than 230F
(110C), the controller changes the position of the ram
air inlet modulation panel.

21-50-00
- 44 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

LEFT AIR CONDITIONING PACK


21-50-00-830 Rev 1 01/26/1999

AIR CONDITIONING - COOLING - RAM AIR TEMPERATURE SENSOR

21-50-00
- 45 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - TURBOFAN CONTROL VALVE
Purpose

The turbofan control valve sends pressure regulated


bleed air to the turbofan turbine. The valve modulates
to control turbofan speed and acts as a shutoff valve.

location

The left turbofan valve is in the aft end of the left


air conditioning compartment inboard of the turbofan.
The right turbofan valve is in the right air
conditioning compartment at the forward end near the
air cycle machine.

Physical Description

The turbofan valve is an electrically controlled,


pneumatically actuated, pressure regulating shutoff
valve. The valve controls the pressure to 30 psi. A
closed limit switch in the valve lets electrical power
operate the ram air controller. An indicator shows the
position of the valve.

Training Information Point

A manual control of the valve actuating solenoid


21-50-00-831 Rev 1 07/12/1999

permits valve operation during ground maintenance.

21-50-00
- 46 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

ACTUATOR
ELECTRICAL
CONNECTOR

SOLENOID

AIR CONDITIONING COMPARTMENT MANUAL


CONTROL
21-50-00-831 Rev 1 01/26/1999

ELECTRICAL
CONNECTOR
LIMIT SWITCH
AND INDICATOR

AIR CONDITIONING - COOLING - TURBOFAN CONTROL VALVE

21-50-00
- 47 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - TURBOFAN CONTROL VALVE - MECHANICAL FUNCTIONAL DESCRPTION
Functional Description

The turbofan control valve is an electrically


controlled, pneumatically actuated, pressure regulating
shutoff valve. The valve regulates the downstream
pressure to 30 psi.

When 28v dc is applied to the open coil of the


solenoid, the latching solenoid valve opens. This lets
air pressure from upstream of the turbofan valve go
supplied to the valve actuator. If the actuator supply
pressure is greater than 8 psi, it is relieved by the
bleed off regulator.

The turbofan valve downstream pressure is sensed by the


sensing selector. If the downstream pressure is more
than 30 psi, the sensing selector opens. This lets air
into the valve actuator move the valve towards closed
position until the downstream pressure is back to 30
psi.
21-50-00-832 Rev 1 01/26/1999

21-50-00
- 48 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

BLEED OFF
MANUAL REGULATOR
OVERRIDE

28V DC

LATCHING
SOLENOID

CLOSED
POSITION SENSING
STOP SELECTOR
21-50-00-832 Rev 1 01/26/1999

FILTER TO TURBOFAN
CAVITY AIR FLOW

CLOSED
LIMIT TO
SWITCH RAM AIR
CONTROL
AIR CONDITIONING - COOLING - TURBOFAN CONTROL VALVE - MECHANICAL FUNCTIONAL DESCRPTION

21-50-00
- 49 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - TURBOFAN CONTROL VALVE - ELECTRICAL FUNCTIONAL DESCRIPTION
Functional Description

The turbofan valve is electrically controlled. It has


two latching solenoids, open and close. When the
airplane is on the ground, the open solenoid energizes
if the ram air actuator is retracted.

After takeoff, the turbofan valve remains open until


the flaps are up and the ram air actuator is extended
past switch S2. At this time, the open solenoid
deenergizes and the close solenoid energizes.

On approach, when the flaps are lowered, the close


solenoid is deenergized and the open solenoid
energizes. The turbofan valve opens.
21-50-00-833 Rev 1 01/26/1999

21-50-00
- 50 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

28V DC
BAT 1 CLOSE
TURBOFAN
VALVE

28V DC TO RAM AIR


BAT BUS ACTUATOR
A/C VALVES
PACK L
K7 PACK
VALVE
NOT CLOSED CLOSED RLY OPEN
TURBOFAN VALVE
CLOSED
POSITION SW
S2
28V DC PACK VALVE
BAT BUS
RAM AIR
RAM MOD ACTUATOR
CONTROL
K5 TURBOFAN
CONTROL RLY
P6 CB PANEL UP
GND R278
AIR
21-50-00-833 Rev 1 01/26/1999

1 NOT UP
MACH TRIM AIR CONDITIONING ACCESSORY UNIT AIR
FLAP SW R320 GND
E11 SHELF
NOTE: LEFT SYSTEM SHOWN,
RIGHT SYSTEM SIMILAR.
1 RIGHT SYSTEM USES STALL WARN SW

AIR CONDITIONING - COOLING - TURBOFAN CONTROL VALVE - ELECTRICAL FUNCTIONAL DESCRIPTION

21-50-00
- 51 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - TURBOFAN
Purpose

The turbofan provides airflow through the ram air


system during low flow conditions. The low flow
conditions are:

- Airplane on the ground


- Airplane in flight with the flaps not up.

Location

The two turbofans are in the air conditioning


compartments, at the aft end of the ram air ducting
just upstream of the ram air exhaust.

Physical Description

The turbofan is a two-stage turbine that drives a fan.


The turbine receives air through the turbofan valve.
When the turbofan operates, outside air is drawn
through the ram air system and heat exchangers. The air
then exhausts overboard through the ram air exhaust.

Training Information Point

A dipstick on the side of the turbofan is used to


21-50-00-834 Rev 1 01/26/1999

measure the oil level. There is one oil sump drain plug
on the bottom of the turbofan. If the oil level is
below the fill line on the dipstick, servicing should
be done. Oil servicing is through the dipstick port.
The oil sump holds 500cc of oil.

21-50-00
- 52 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

AIR CONDITIONING COMPARTMENT


AIR SUPPLY FROM
TURBOFAN CONTROL
VALVE
DIPSTICK AND
FILL PORT

TURBOFAN

FWD
21-50-00-834 Rev 1 01/26/1999

FLEXIBLE
DUCT
RAM AIR
EXHAUST SUMP DRAIN
TURBOFAN PLUG

LEFT SIDE FWD RIGHT SIDE

AIR CONDITIONING - COOLING - TURBOFAN

21-50-00
- 53 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - RAM AIR SYSTEM - FUNCTIONAL DESCRIPTION
THIS PAGE INTENTIONALLY LEFT BLANK
21-50-00-835 Rev 1 03/26/2001

21-50-00
- 54 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - RAM AIR SYSTEM - FUNCTIONAL DESCRIPTION
General The K16 ram air actuator disable relay is energized.
This removes the left pack zone controller from the ram
The ram air system controls the air flow through the air inlet actuator.
primary and secondary heat exchangers. These are the
ram air control components: There is 115v ac that goes through these relay contacts
to supply a retract signal to the left ram air
- Pack/zone temperature controller actuator:
- Ram air inlet actuator
- Ram air control temperature sensor - Ram BITE enable (K15 - NORMAL)
- Ram air inlet deflector door - Ram mod control (K5 - OPEN)
- Ram air inlet modulation panels - Pack air/ground (K10 - GROUND)
- Ram air ducts. - Ram air actuator disable (K16 - RETRACT).

These are the three modes of control for the ram air The left ram air actuator has internal switches that
system: connect power to the actuator. When the actuator is in
the full retracted position, the modulation panels are
- Ground full open, and the deflector door is extended. The S1
- Flight (flaps not up) switch opens to remove power to the motor.
- Flight cruise (flaps up).
The S3 switch in the ram air actuator connects a ground
The air conditioning accessory unit (ACAU) relays to the air conditioning/bleed air controls panel. This
control power to the pack/zone temperature controller causes the left RAM DOOR FULL OPEN light to come on.
and the ram air inlet actuator.
Flight (Flaps Not Up)
There are different control circuits for the left and
right ram air systems. At takeoff the AIR/GND sensing system opens to
21-50-00-835 Rev 1 03/26/2001

deenergize the K10 relay. The K5 relay stays energized


Ground Mode with a ground from the flaps switch when the flaps are
not up.
When the airplane is on the ground, the AIR/GND sensing
system supplies a discrete (ground) to energize the K10 Power to the motor extend coils comes through the
pack air ground relay and the K5 ram mod control relay. internal S2 switch at takeoff. The deflector door moves

21-50-00
- 55 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - RAM AIR SYSTEM - FUNCTIONAL DESCRIPTION
out of the airstream when the actuator shaft is at the BITE
S2 switch position. The RAM DOOR FULL OPEN light is on.
When BITE is done with the pack/zone temperature
Flight Cruise (Flaps Up) controller, relay K15 energizes. This causes a
simulation of the on-ground position regardless of flap
In flight when the flaps are at a full up position, the position.
K5 relay deenergizes. This deenergizes the K16 relay
and gives the pack/zone controller control of the ram Training Information Point
air inlet actuator.
If the RAM DOOR FULL OPEN light is on during flight
The left turbofan valve closes and the turbofan stops. cruise mode, it can be one of these three possible
problems:
The ram air control circuits in the pack/zone
controller supply command signals to the actuator. The - Ram air system has a blockage
pack/zone controller gets temperature signals from the - Heat exchangers are dirty
ram air sensor. The ram air sensor sends temperature - Electrical failure.
signals from the air cycle machine (ACM) compressor
outlet. The controller uses the air (temperature) NOTE: The left side uses the flaps switch and the right
sensor signal in a bridge circuit. The bridge circuit side uses the stall warning switch.
reads the ACM compressor temperature as an error
signal, too hot or too cold. The nominal (balanced)
control temperature is 230F/110C. The pack/zone
controller opens or closes the ram air inlet modulation
panels to keep this balance.

The normal position for the ram air inlet modulation


21-50-00-835 Rev 1 03/26/2001

panel in flight with the flaps up is faired (closed).


This is to decrease drag. In this condition the RAM
DOOR FULL OPEN light is off.

21-50-00
- 56 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

115V AC POWER IN
XFR AIR COND
BUS 1 RAM AIR
MOD - L
AIR MODULATE
28V DC RETRACT
BUS 1
AIR COND EXTEND
RAM AIR MOD
CONT - L CLOSE
GROUND
28V DC K10 PACK RAM AIR
BAT BUS AIR/GND CONTROL
SENSOR
AIR COND NORMAL RETRACT
PACK CONT
VALVES - L OPEN K16 RAM AIR PACK/ZONE LEFT RAM
K5 RAM MOD ACTUATOR CONTROLLER AIR SENSOR
P6 CB PANEL CTRL DISABLE

GND AIR
K15 RAM BITE
ENABLE RELAY
28V DC TO TF
GND OPEN K7, K5 VALVE
AIR R320
R276
E11 SHELF S2 S3
CLOSE EXTEND
UP (CLOSE)
K7 PACK VALVE
CLOSED RELAY
21-50-00-835 Rev 1 03/26/2001

OPEN CLOSE
NOT UP
FLAPS SW LEFT ACAU RETRACT
(OPEN)
28/16V DC RAM DOOR
MASTER DIM FULL OPEN b S1 S4
SECT 1
A/C PANEL (P5)
P6 CB PANEL LEFT RAM AIR ACTUATOR
AIR CONDITIONING - COOLING - RAM AIR SYSTEM - FUNCTIONAL DESCRIPTION

21-50-00
- 57 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - AIR CYCLE MACHINE
Purpose

The air cycle machine (ACM) decreases air temperature,


by expansion through a turbine.

Location

The air cycle machine is in the air conditioning


compartment. There is an ACM for each of the left and
right pack systems.

Physical Description

The air cycle machine is a high-speed rotating


assembly. It has these two sections connected by a
common shaft:

- Turbine
- Compressor.

Bearings support the shaft. The bearings are oil


lubricated by a reservoir/wick system.

Training Information Point

The ACM is properly serviced when the oil level is at


21-50-00-813 Rev 1 03/26/2001

the 3/4 level on the sight gauge.

21-50-00
- 58 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

AIR CONDITIONING COMPARTMENT

OIL FILLER
PORT (2)
SIGHT
GAUGE (2)

COMPRESSOR
INLET
21-50-00-813 Rev 1 03/26/2001

TURBINE
OUTLET

TURBINE DRAIN COMPRESSOR


SECTION PLUG SECTION
AIR CONDITIONING - COOLING - AIR CYCLE MACHINE

21-50-00
- 59 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - WATER EXTRACTOR DUCT
Purpose pressure in the extractor forces the water out of the
sump into the drain boss. A line connects the drain
The water extractor duct removes water from the air boss to the water spray nozzle.
conditioning pack ducts.

Location

There are two water extractor ducts, one in each air


conditioning pack. The water extractor ducts are in the
air conditioning ducts downstream of the secondary heat
exchangers.

Physical Description

The water extractor ducts have these parts:

- Inlet
- Outlet
- Sump
- Drain boss.

These devices support the extractor ducts:

- Flange clamp (inlet)


- Rubber hose and band clamps (outlet).
21-50-00-818 Rev 1 01/21/1999

Functional Description

The water extractors are coaxial split-can type gravity


fluid separators.

Water in the airstream falls into the sump of the water


extractor duct. The sump collects the water and

21-50-00
- 60 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

AIR CONDITIONING COMPARTMENT

SUMP
OUTLET
21-50-00-818 Rev 1 03/26/2001

INLET

WATER EXTRACTOR DUCT

AIR CONDITIONING - COOLING - WATER EXTRACTOR DUCT

21-50-00
- 61 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - REHEATER
Purpose Functional Description

The reheater increases the temperature of the air in The reheater is a a plate-fin, single-pass, crossflow,
the air conditioning pack before it enters the turbine air-to-air heat exchanger. It is made of aluminum.
of the air cycle machine. This increases the efficiency
of the turbine. The reheater is a regenerative-type heat exchanger. It
has these functions:
Location
- Precools the pack air from the secondary heat
There are two reheaters, one for each air conditioning exchanger before it enters the condenser
pack. The reheaters are part of high pressure water - Reheats the pack air as it leaves the water
separator assemblies. These assemblies are in the extractors.
forward area of the air conditioning pack compartments.
Training Information Point
Physical Description - Reheaters
The reheater is part of the high pressure water
The reheaters have these features: separator assembly. To remove the reheater, first
remove the water separator assembly.
- Inlet (hot stream from secondary heat exchanger)
- Outlet (cooled) to condenser You must remove the left air conditioning pack high
- Reheater core case pressure water separator to get access to the center
- Inlets (cold stream from water extractors) fuel tank access panel.
- Outlet (warmed) to air cycle machine turbine
- Pack sensor bosses.

These pack bulbs are on the reheater:


21-50-00-819 Rev 1 11/23/1999

- Pack temperature sensor


- Pack temperature bulb.

21-50-00
- 62 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

WATER
EXTRACTORS CONDENSER
(REF) (REF)

CORE
CASE
HOT AIR INLET
FROM SECONDARY OUTLET TO
HEAT EXCHANGER AIR CYCLE
MACHINE
TURBINE

OUTLET TO
CONDENSER

FWD AIR CONDITIONING COMPARTMENT


21-50-00-819 Rev 1 03/26/2001

SENSOR
BOSS (TYP)
COLD AIR
INLETS FROM
WATER
EXTRACTORS

AIR CONDITIONING - COOLING - REHEATER

21-50-00
- 63 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - CONDENSER
Purpose The air cools enough to condense moisture. Part of the
cold air bypasses around the condenser core and warm
The condenser decreases the temperature of the air in air comes through de-icing passages in the face of the
the air conditioning pack to below the dew point. This core to prevent ice on the cold air face of the core. A
causes the water vapor in the airstream to go into a free passage between the two condenser cores is an
liquid form. fail-safe if there is ice.

Location Delta pressure sense line bosses connect the sense


lines to the pneumatic servo-actuator of the standby
There are two condensers, one in each air conditioning temperature control valve. Ice in the condenser creates
pack. The condensers are part of the high pressure a differential pressure that is enough to open the
water separator assemblies. These assemblies are in the standby temperature control valve. Warm air from the
forward area of the air conditioning pack compartments. standby temperature control valve, ported into the high
pressure water separator mix muff, warms the condenser
Physical Description and melts the ice.

The condenser has these parts:

- Inlet (hot stream from reheater)


- Outlet (warmed) to pack discharge check valve
- Outlet manifold (cooled) to water extractors
- Condenser core case
- Inlet (cold stream from turbine discharge)
- Delta pressure sense line bosses.

Functional Description
21-50-00-820 Rev 1 01/21/1999

The condenser is a plate-fin, single-pass, crossflow,


air-to-air heat exchanger. It is made of aluminum.

The condenser uses turbine discharge air to cool the


pack air after it makes the first pass through the
reheater.

21-50-00
- 64 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

CONDENSER (REF)

COLD OUTLET
(TO DISTRIBUTION
SYSTEM)

HOT INLET
HOT OUTLET (FROM REHEATER)
(TO WATER ANTI ICE PORT
EXTRACTOR) (FROM COMPRESSOR
DISCHARGE)

AIR CONDITIONING COMPARTMENT


FWD
21-50-00-820 Rev 1 03/26/2001

COLD INLET
(FROM TURBINE)
STANDBY TCV
DOWNSTREAM
SENSE PORT HOT OUTLET
1 (TO WATER
1 THE UPSTREAM SENSE PORT IS LOCATED ON EXTRACTOR)
THE HOT INLET SIDE OF THE CONDENSER

AIR CONDITIONING - COOLING - CONDENSER

21-50-00
- 65 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - WATER EXTRACTOR
Purpose The inlet of the water extractor has a swirl chamber to
create a vortex airflow. The water part of the
The water extractors remove water from the air airstream goes into the outer shell of the extractor by
conditioning pack air. centrifugal force. A sump collects the water and
pressure in the extractor forces the water out of the
Location sump into the drain nipples. Lines connect the drain
nipples to the water spray nozzle.
There are four water extractors, two in each air
conditioning pack. The water extractors are part of The water spray nozzle injects the water into the ram
high pressure water separator assemblies. These air duct. This cools the ram air stream by evaporation.
assemblies are in the forward area of the air
conditioning pack compartments.

Physical Description

The water extractors have these parts:

- Inlet
- Outlet
- Swirl chamber
- Sump
- Water drain nipples.

A rubber hose and band clamps connect the water


extractor inlet to the condenser. A flange clamp
connects the water extractor outlet to the reheater.
21-50-00-821 Rev 1 01/21/1999

Hoses and band clamps connect the water drain nipples


to the water spray nozzle lines.

Functional Description

The water extractors are inertial-type centrifugal flow


fluid separators.

21-50-00
- 66 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

SWIRL VANES
REHEATER WATER CONDENSER
(REF) EXTRACTORS (REF)

CUTAWAY VIEW

SWIRL
CHAMBER

OUTER
SHELL

INLET
WATER
DRAIN
NIPPLES
AIR CONDITIONING COMPARTMENT
FWD
21-50-00-821 Rev 1 03/26/2001

SUMP

OUTLET

AIR CONDITIONING - COOLING - WATER EXTRACTOR

21-50-00
- 67 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - WATER SPRAY NOZZLE
Purpose

The water spray nozzle takes water from the air


conditioning pack water extractor devices and injects
it into the ram air inlet duct.

Location

There are two water spray nozzles, one for each air
conditioning pack. They are on the outboard bulkhead of
the air conditioning compartments.

Physical Description

The water spray nozzles have these parts:

- Water line inlets


- Spray nozzle.

Functional Description

Water extractor devices remove water in the air


conditioning pack airstream. Lines carry the water from
the extractors to the water spray nozzles. The water
spray nozzle injects the water into the ram air duct.
This cools the ram air stream by evaporation.
21-50-00-822 Rev 1 01/21/1999

Training Information Point

If there is a clogged nozzle, a drain on the HPWS dumps


the water into the air conditioning bay so it will not
go into the air cycle machine turbine.

21-50-00
- 68 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

WATER
INLET
AIR
INLET

AIR CONDITIONING COMPARTMENT


21-50-00-822 Rev 1 03/26/2001

WATER SPRAY NOZZLE

AIR CONDITIONING - COOLING - WATER SPRAY NOZZLE

21-50-00
- 69 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - HIGH PRESSURE WATER SEPARATOR MIX MUFF
Purpose

The high pressure water separator mix muff mixes the


warm air from the pack temperature control valves with
the cold discharge air from the air cycle machine
turbine.

Location

There are two high pressure water separator mix muffs.


They are in the air conditioning pack compartments
between the air cycle machines and the condensers.

Physical Description

The high pressure water separator mix muffs have these


parts:

- Temperature control valve inlets


- Turbine discharge inlet
- Outlet
- Air cycle machine de-icing line boss.

Functional Description

The high pressure water separator mix muffs are duct


21-50-00-823 Rev 1 01/21/1999

manifolds. They have interior baffles to mix the hot


and cold input airstreams.

21-50-00
- 70 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

COLD AIR INLET


(ACM DISCHARGE)
HOT AIR INLET
(TCV DISCHARGE)

AIR CONDITIONING COMPARTMENT


21-50-00-823 Rev 1 03/26/2001

MIXED AIR
OUTLET
ACM ANTI-ICING
LINE BOSS

AIR CONDITIONING - COOLING - HIGH PRESSURE WATER SEPARATOR MIX MUFF

21-50-00
- 71 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - CONDITIONED AIR CHECK VALVE
Purpose

The conditioned air check valve lets one-way air flow


from the pack to the main distribution manifold.

The packs supply pressurized air through the check


valve to the distribution system. The check valve
prevents airflow from the pressurized distribution
system to the unpressurized air conditioning
compartment.

Location

The conditioned air check valve is in the forward


section of the air conditioning bay.

Physical Description

The conditioned air check valve is a swing type check


valve. An arrow on the outside of the valve shows the
flow direction.

There is one conditioned air check valve in each pack


system.

Functional Description
21-50-00-828 Rev 1 01/26/1999

The check valve prevents airflow to the pack. It opens


to permit air flow from the air conditioning pack to
the main distribution manifold.

21-50-00
- 72 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

FWD

CLAMPS

AIR CONDITIONING COMPARTMENT


21-50-00-828 Rev 1 03/26/2001

AIR CONDITIONING - COOLING - CONDITIONED AIR CHECK VALVE

21-50-00
- 73 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - PACK TEMPERATURE SENSOR
Purpose

The pack temperature sensor measures the temperature in


the air conditioning pack. It gives feedback to the
pack/zone temperature controllers.

Location

There are two pack temperature sensors, one in each air


conditioning pack. They are on the pack high pressure
water separator assemblies. Access is through the air
conditioning compartment doors.

Functional Description

The pack temperature sensors are thermistor devices.


Their resistance changes with temperature.

The temperature sensor resistance is the feedback to


the pack/zone temperature controller. The pack/zone
temperature controller uses the feedback to control the
discharge temperature of the air conditioning system.

Each pack temperature sensor has two sense elements.


One element to give feedback to each of the two
pack/zone temperature controllers. One element gives
21-50-00-894 Rev 1 01/18/1999

pack temperature feedback to the auto (normal) control


of its related pack/zone temperature controller. The
other element gives pack temperature feedback to the
standby control of the opposite pack/zone temperature
controller.

21-50-00
- 74 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

PACK
TEMPERATURE
SENSOR
21-50-00-894 Rev 1 03/26/2001

FWD LEFT AIR CONDITIONING PACK

AIR CONDITIONING - COOLING - PACK TEMPERATURE SENSOR

21-50-00
- 75 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - MIX MANIFOLD TEMPERATURE SENSOR
Purpose

The mix manifold temperature sensors measure the


temperature in the mix manifold of the air conditioning
system. They give feedback to the pack/zone temperature
controllers.

Location

There are two mix manifold temperature sensors. They


are similar in design and operation. They are on the
upper forward wall of the mix manifold. Access is
through the center aft bulkhead panel in the forward
cargo compartment.

Functional Description

The mix manifold temperature sensors are thermistor


devices. Their resistance changes with temperature.

The temperature sensor resistance is the feedback to


the pack/zone temperature controller. The pack/zone
temperature controller uses the feedback to prevent
freezing temperatures in the air conditioning
distribution system.
21-50-00-893 Rev 1 06/03/1999

21-50-00
- 76 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

MIX MANIFOLD
TEMPERATURE SENSOR
(2)
21-50-00-893 Rev 1 01/18/1999

DISTRIBUTION BAY FWD

AIR CONDITIONING - COOLING - MIX MANIFOLD TEMPERATURE SENSOR

21-50-00
- 77 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - TEMPERATURE CONTROL VALVE
Purpose Training Information Point

The temperature control valve is the primary valve to There is a position indicator on the temperature
control the discharge temperature of the air control valve. The valves are normally in the closed
conditioning pack. position when the packs are off.

Location You can manually close the valve with the manual
override knob if the electric motor fails. Turn the
There are two temperature control valves, one for each knob in the direction shown on the knob placard.
air conditioning pack. They are in the air conditioning
compartments.

Physical Description

The temperature control valve has these parts:

- Valve flow body


- Electric motor actuator assembly
- Position indicator
- Manual override knob.

Two vee-flange clamps support the valve.

Functional Description

The valve is an electric motor-driven single plate


21-50-00-825 Rev 1 03/13/2000

butterfly valve. A mechanical gear train with a slip


clutch transfers motor motion to the valve.

The valve uses 115v ac power. The valve drive signal


comes through the ACAU from the pack zone controllers.

21-50-00
- 78 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

VALVE
POSITION ELECTRIC
INDICATOR MOTOR
ASSEMBLY

MANUAL
OVERRIDE
AIR CONDITIONING COMPARTMENT KNOB

ELECTRICAL
CONNECTOR
21-50-00-825 Rev 1 03/26/2001

AIR CONDITIONING - COOLING - TEMPERATURE CONTROL VALVE

21-50-00
- 79 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - STANDBY TEMPERATURE CONTROL VALVE
Purpose Functional Description

The standby temperature control valve does these The valve is a pneumatically actuated butterfly-type
things: modulating and shutoff valve. It is spring-loaded to
the closed position.
- Gives backup control for the discharge temperature
of the air conditioning pack (normal temperature Control pressure to the actuator opens and modulates
control system failure) the valve. The control pressure source is the upstream
- Increases the temperature of pack discharge air to side of the valve. These valve devices control the
prevent ice formation in the condenser. pressure to the valve actuator:

Location - Electromagnetic control valve assembly


- Delta pressure servo control assembly.
There are two standby temperature control valves, one
for each air conditioning pack. They are in the air A signal from the pack zone controller standby pack
conditioning pack compartments. control channel drives the electromagnetic control
device.
Physical Description
Pneumatic lines sense condenser differential pressure
The standby temperature control valve has these parts: and drive the delta pressure servo control device. Ice
in the condenser increases the pressure differential.
- Valve flow body
- Electromagnetic control valve assembly If the electromagnetic and the delta pressure controls
- Delta pressure servo control assembly operate at the same time, the device that gives the
- Pneumatic actuator largest valve open pressure will control.
- Position indicator
21-50-00-824 Rev 1 01/26/1999

- Sense ports. Training Information Point

Two V-band clamps support the valve. There is a position indicator on the standby
temperature control valve. The valve is normally in the
closed position when the pack is off.

21-50-00
- 80 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

DELTA PRESSURE
ELECTROMAGNETIC SERVO CONTROL
CONTROL VALVE ASSEMBLY
ASSEMBLY POSITION
INDICATOR
PNEUMATIC
ACTUATOR

AIR CONDITIONING COMPARTMENT

SENSE PORT TO
CONDENSER OUTLET
21-50-00-824 Rev 1 03/26/2001

MOUNTING
FLANGE
FLOW
SENSE PORT TO BODY
CONDENSER INLET

AIR CONDITIONING - COOLING - STANDBY TEMPERATURE CONTROL VALVE

21-50-00
- 81 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - STANDBY TEMPERATURE CONTROL VALVE - FUNCTIONAL DESCRIPTION
Functional Description

The standby temperature control valve is electrically


and pneumatically controlled and pneumatically
operated.

If the condenser begins to ice, differential pressure


across the condenser is sensed. This differential
pressure acts on the high pressure delta P servo.

The servo operates a poppet valve to control the


actuation pressure that goes from the reference
pressure regulator to the pneumatic actuator. This
opens the valve and increases the hot air flow into the
condenser. With the increased hot airflow, the
condenser will deice and the valve closes.

Electrical control of the standby temperature control


valve is part of the standby mode of operation. The
standby temperature control electrically moves a
flapper in the electromagnetic control valve to control
actuation pressure to the pneumatic actuator.

If there are simultaneous signals from the differential


pressure sensors and the electromagnetic control valve,
the device with the higher demand has priority.
21-50-00-826 Rev 1 03/26/2001

21-50-00
- 82 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

CONDITIONED
CONDENSER CONDENSER AIR CHECK VALVE
INLET OUTLET DELTA P
SERVO TURBINE
AMBIENT POPPET AMBIENT MUFF
VENT VENT

LOW PRESSURE
DELTA P
SERVO

REFERENCE FLAPPER
PRESSURE REGULATOR ELECTROMAGNETIC
HIGH PRESSURE SUPPLY CONTROL VALVE
AMBIENT NOZZLE
DELTA P SERVO VENT
AMBIENT
VENT
CHAMBER A

POPPET
VALVE
OPEN
CHAMBER
VENT
RESTRICTOR
PNEUMATIC
ACTUATOR AMBIENT
21-50-00-826 Rev 1 03/26/2001

VENT

INLET

TRAILING DISK OPEN STOP


PROBE ADJUSTMENT

AIR CONDITIONING - COOLING - STANDBY TEMPERATURE CONTROL VALVE - FUNCTIONAL DESCRIPTION

21-50-00
- 83 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - AUTO CONTROL - FUNCTIONAL DESCRIPTION
Functional Description The mix manifold temperature input to the pack/zone
controller is from two sensors on the mix manifold. The
When you put the pack switch to the AUTO/HIGH position, pack/zone temperature controller compares the two
K13 PACK/HIGH relay energizes if the K7 pack valve inputs and uses the coldest signal. The mix manifold
closed relay is open. When K13 is energized, the temperature and the PACK DEMAND are then compared with
pack/zone controller is enabled and the K17 pack a 35F (2C) limit and the controller controls the
temperature control valve inop relay is energized. temperature control valve.

K21 alternate power relay gives two possible sources Open and close limit switches in the temperature
for electrical power. When K21 energizes, it gives 28v control valve provide feedback signals to the pack/zone
dc from bus 1. When K21 de-energizes, it gives 28v dc temperature controllers.
from the battery bus. 28v dc goes to these relays:
When the zone temperature selectors are in the OFF
- K13 pack AUTO/HIGH relay position, the pack/zone temperature controller uses a
- K17 pack TCV INOP relay. fixed 75F (24C) demand to establish the temperature
control of the pack.
The pack/zone temperature controller controls the
position of the temperature control valve. To move the These are the failures that cause the temperature
temperature control valve, the auto pack control in the control valve to close and activate the standby
pack/zone temperature controller compares the temperature control in the opposite controller:
temperature requirements of the three zones. The
pack/zone temperature controller satisfies the - Pack control
temperature requirement of the zone that needs the most - Pack sensor or interface
cooling. The controller uses this temperature - Temperature control valve or driver.
requirement as a PACK DEMAND signal to establish the
temperature output of the pack. The temperature These failures set the pack INOP and FAULT switches.
21-50-00-805 Rev 1 01/31/2001

requirement is compared with the actual pack outlet


temperature sensed by the pack temperature sensor. This
signal is compared with a 35F (2C) limit for ice
protection of the mix manifold.

Ice protection is provided for the mix manifold by a


35F (2C) temperature limit to the output of the pack.

21-50-00
- 84 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

115V AC OPEN
XFR BUS 1 A OPEN
28V DC L TCV CLOSE
BAT BUS
L PACK CONTROL K15 BITE K7 PACK VALVE
28V DC ENABLE RELAY CLOSED RELAY CLOSE
BUS 1
L PACK VALVE
115V AC K17 PACK TCV
XFR BUS 1 INOP RELAY
L PACK CONTROL
P6 CB PANEL

K8 PACK
OVHT RELAY

AUTO/HIGH

K13 PACK FULL CLOSE


OFF AUTO/HIGH RELAY
L PACK SW L ACAU (E3-2)
(P5) GROUND = ENABLE A
INDICATION
PACK INOP CIRCUIT
OPEN = INOP
BITE
L MIX MANIFOLD
TEMP SENSOR DRIVER FULL OPEN
PACK FAULT
OPEN = FAULT
21-50-00-805 Rev 1 06/09/2001

INDICATION
CIRCUIT
LEFT TEMP
LOGIC CONTROL VALVE
B
LEFT AUTO PACK CONTROL ACTIVATE STANDBY
B PACK CONTROL
L PACK TEMP LEFT PACK/ZONE TEMPERATURE CONTROLLER (E2-3)
SENSOR RIGHT PACK/ZONE TEMP
CONTROLLER (E2-3)
AIR CONDITIONING - COOLING - AUTO CONTROL - FUNCTIONAL DESCRIPTION

21-50-00
- 85 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - STANDBY CONTROL - FUNCTIONAL DESCRIPTION
Purpose

The standby temperature control provides temperature


control of the pack output if there is a pack automatic
control failure.

Functional Description

When you put the pack switch to the AUTO/HIGH position,


K13 PACK/HIGH relay energizes if the K7 pack valve
closed relay is open. When K13 is energized, the
pack/zone controller is enabled. If the pack automatic
temperature control fails, there is an activate standby
pack command signal. This connects the opposite
controller to the standby temperature control valve for
temperature control.

The standby pack control uses the standby temperature


control valve to regulate the output of the pack.

If all zone and auto pack temperature controls fail,


the analog standby pack temperature controls will
satisfy the average temperature demand of the two
passenger cabin zones. The flight compartment zone is
not used.
21-50-00-806 Rev 1 03/27/2001

NOTE: If the auto and standby pack temperature controls


fail, the pack should be shutdown. If this is not
done, the pack continues to operate until an
overtemperature condition occurs.

21-50-00
- 86 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
28V DC
BAT BUS
L PACK
VALVE AUTO/HIGH OPEN
P6 CB PANEL
CLOSE
OFF K13 PACK
K7 PACK VALVE CLOSED RLY AUTO/HIGH RELAY
L PACK SW (P5)
L AIR COND PACK ENABLE/OFF
1 ACCESS UNIT (E3-2) GND = ENABLE
FAULT
GND = FAULT
PACK
LEFT AUTO DEMAND
FWD PASS COMPT PACK CONTROL BITE
TEMP SENSOR FAULT STANDBY PACK FAULT
GND = FAULT INDICATION CIRCUIT
PACK INOP A STBY
PACK
1 DEMAND AFT PASSENGER COMPT
RIGHT STANDBY INDICATION CIRCUIT
PACK CONTROL RIGHT AUTO PACK CONTROL

60F/ A
L PACK/ZONE RIGHT AUTO
FWD PASS COMPT CONTROLLER (E3-3) 15C
TEMP SELECTOR MIN PACK CONTROL ACTIVATE STBY
FAILURE PACK COMMAND
A
V 60F TO
G 145F DRIVER
LIMIT
1
LEFT STANDBY PACK CONTROL LEFT
AFT PASS COMPT 1 R PACK/ZONE STANDBY
21-50-00-806 Rev 1 03/27/2001

TEMP SELECTOR CONTROLLER (E2-3) TCV


AFT PASS COMPT
TEMP SENSOR

1 NOTE: LEFT STBY TEMP CONTROL SHOWN,


RIGHT STBY TEMP CONTROL SIMILAR
LEFT PACK TEMP SENSOR 1 AUTO ZONE TEMP CONTROL SIGNAL
AIR CONDITIONING - COOLING - STANDBY CONTROL - FUNCTIONAL DESCRIPTION

21-50-00
- 87 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - PACK OVERHEAT SWITCHES
Purpose The turbine inlet overheat switch has an operation
temperature of 210F (99C).
These temperature switches monitor the pack for an
overheat condition: The pack discharge overheat switch has an operation
temperature of 250F (121C).
- Compressor discharge overheat switch
- Turbine inlet overheat switch Training Information Point
- Pack discharge overheat switch.
CAUTION: USE TWO WRENCHES WHEN YOU REMOVE/INSTALL THE
Location SWITCH IN/OUT OF THE BOSS. THIS WILL PREVENT
DAMAGE TO THE DUCT.
There is a compressor discharge overheat switch and a
turbine inlet overheat switch in each air conditioning
compartment.

The compressor discharge overheat switch is in the duct


between the air cycle machine compressor section and
the secondary heat exchanger.

The turbine inlet overheat switch is in the duct from


the reheater to the air cycle machine turbine section.

The pack discharge overheat switch is in the input duct


to the mix manifold in the distribution bay.

Functional Description
21-50-00-836 Rev 1 01/20/1999

The overheat switches look similar. The compressor


discharge overheat switch and the turbine inlet
overheat switch have different operation temperatures.

The compressor discharge overheat switch has an


operation temperature of 390F (199C).

21-50-00
- 88 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

TURBINE INLET
OVERHEAT SWITCH

FWD
PACK DISCHARGE
OVERHEAT SWITCHES (2)

PROBE
PROBE
SWITCH
HOUSING
21-50-00-836 Rev 1 01/20/1999

ELECTRICAL
CONNECTOR

COMPRESSOR DISCHARGE
OVERHEAT SWITCH
FWD
OVERHEAT SWITCH AIR CONDITIONING COMPARTMENT

AIR CONDITIONING - COOLING - PACK OVERHEAT SWITCHES

21-50-00
- 89 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - PACK PROTECTION - FUNCTIONAL DESCRIPTION
Functional Description

Pack protection is a function of these three switches:

- Compressor discharge overheat switch


- Turbine inlet overheat switch
- Pack discharge duct overheat switch

The switches are normally open. When an overheat


condition occurs, the overheat switch closes. This
energizes the pack overheat relay. When the pack
overheat relay energizes, power is supplied to the
close solenoid of the flow control and shutoff valve.

These are the indications when a pack trip occurs:

- PACK amber light


- MASTER CAUTION and AIR COND annunciator lights.

The overheat relay latches in the overheat position.


When the condition that caused the pack trip off is
corrected, push the TRIP RESET switch on the air
conditioning/bleed air control panel to de-energize the
overheat relay.

Training Information Point


21-50-00-827 Rev 1 04/22/1999

If the PACK light comes on and the pack can be reset,


the heat exchangers may be obstructed or dirty.

If the PACK light comes on and the pack can not be


reset, do a test of the compressor discharge and
turbine inlet overheat switches.

21-50-00
- 90 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

28V DC OFF NORM OPEN


BAT BUS
AIR CONDITIONING
VALVE PACK - L
AUTO CLOSE
HIGH
LEFT PACK
LEFT PACK SWITCH FLOW CONTROL
TO MASTER AND SHUTOFF VALVE
CAUTION

28/16V DC PACK 390F/199C


MASTER DIM a
SEC 1 LEFT COMPRESSOR
DISCHARGE OVHT SW

250F/121C
TRIP RESET SWITCH
AIR CONDITIONING/BLEED AIR LEFT PACK DISCHARGE
CONTROL PANEL (P5) DUCT OVHT SW
28V DC
BAT BUS
AIR CONDITION
21-50-00-827 Rev 1 03/08/1999

OVERHEAT
OVHT 210F/99C
P6 CB PANEL
K8 LEFT PACK LEFT TURBINE INLET
OVHT RELAY OVERHEAT SWITCH
AIR CONDITIONING
NOTE: LEFT PACK PROTECTION SHOWN. ACCESSORY UNIT
RIGHT PACK SIMILAR.

AIR CONDITIONING - COOLING - PACK PROTECTION - FUNCTIONAL DESCRIPTION

21-50-00
- 91 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - FUNCTIONAL DESCRIPTION
THIS PAGE INTENTIONALLY LEFT BLANK
21-50-00-803 Rev 1 03/26/2001

21-50-00
- 92 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - FUNCTIONAL DESCRIPTION
Functional Description When the compressed air goes through the secondary heat
exchanger, ram air removes some of the heat. This bleed
The flow control and shutoff valve gets hot bleed air air goes through the water extractor duct and into the
from the pneumatic manifold. The flow control and reheater.
shutoff valve controls the flow of hot bleed air to the
trim air system, primary heat exchanger and to the two Bleed air that leaves the secondary heat exchanger goes
temperature control valves. A hot air connection through the hot side of the reheater. Air that goes
downstream of the FCSOV supplies hot bleed air to the through the reheater the first time is cooled by colder
turbine case. This prevents ice in the turbine case. air from the condenser. The temperature of the bleed
air increases as it goes through the reheater a second
The ram air system controls the flow of ram air to the time and into the turbine section of the air cycle
primary and secondary heat exchangers. These are the machine.
ram air system components:
Air that leaves the turbine goes through the cold side
- Ram air inlet control temperature sensor of the condenser. Air flow from the condenser divides
- Pack/zone temperature controller into two paths, each path goes through a water
- Ram air inlet actuator extractor.
- Ram air inlet deflector door
- Ram air inlet modulation panels The water extractors remove moisture. This moisture
- Ram air exit louvers goes to the water spray nozzle. The water spray nozzle
- Turbofan valve sprays the water into the ram air duct.
- Turbofan.
Part of the cold air bypasses through the condenser
When bleed air goes through the primary heat exchanger, core to prevent ice in the condenser. This supplies
ram air removes some of the heat. This partially cool warm air through deicing passages in the core and by a
bleed air goes to the compressor section of the air mix of hot bleed air into the turbine muff at the cold
21-50-00-803 Rev 1 03/26/2001

cycle machine. air inlet. The standby temperature control valve senses
condenser ice conditions and sends hot bleed air to the
The compressor section increases the pressure and turbine muff.
temperature of the partially cool bleed air. This
compressed air goes to the secondary heat exchanger.

21-50-00
- 93 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - FUNCTIONAL DESCRIPTION
Overheat Protection

The pack has overheat protection components that


automatically stop operation of the pack. These are the
overheat protection components:

- Compressor discharge overheat switch 390F (199C)


- Turbine inlet overheat switch 210F (99C)
- Pack discharge overheat switch 250F (121C).
21-50-00-803 Rev 1 03/26/2001

21-50-00
- 94 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

TCV FCSOV
TO TRIM
AIR
STBY TCV PACK/ZONE
CONTROLLER
CONDITONAL
AIR CHECK VALVE CONDENSER S RAM AIR
ACTUATOR
PACK
DISCHARGE ACM TURBOFAN A
OVHT SW DIFFUSER

WATER
EXTRACTORS PACK
TEMP REHEATER
SENSOR RAM AIR
TURBINE EXIT
OVHT SW LOUVERS

COMPRESSOR PRIMARY
OVHT SW RAM AIR HEAT TURBOFAN
PACK TEMP SENSOR EXCHANGER VALVE
BULB
SECONDARY
21-50-00-803 Rev 1 03/26/2001

RAM AIR WATER EXTRACTOR HEAT


DEFLECTOR DUCT EXCHANGER
DOOR
WATER SPRAY
A NOZZLE

RAM AIR MODULATION PANELS


AIR CONDITIONING - COOLING - FUNCTIONAL DESCRIPTION

21-50-00
- 95 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- DISTRIBUTION - INTRODUCTION
Purpose Passenger Cabin Conditioned Air Distribution

The distribution system has these functions: The passenger compartment has two zones for
independently controlled air temperature. There are
- Divides conditioned air to the three airplane supply ducts that supply a constant flow to all areas.
zones In each zone, the conditioned air goes to these areas:
- Reduces engine bleed requirements
- Removes offensive air from lavatories and galleys - Passenger cabin
- Supplies cooling air to electronic equipment. - Lavatories
- Galleys.
Main Air Distribution
Recirculation System
The main air distribution components send conditioned
air to these zones: The recirculation system permits ventilation of air in
the passenger cabin areas. The recirculation system
- Flight compartment decreases the use of engine bleed air. This enables
- Forward passenger compartment better thrust management and decreases fuel
- Aft passenger compartment. consumption.

Conditioned air comes from these sources: Ventilation System

- Ground supplied conditioned air Vent ports adjacent to the lavatory and galleys let air
- Air conditioning packs in those areas flow overboard.
- Recirculation system.
Equipment Cooling
Flight Compartment Distribution
21-20-00-801 Rev 1 03/22/2001

The equipment cooling system uses fans to move air


The flight compartment has an independent source of around equipment in the EE compartment and flight
conditioned air. This provides a constant supply of compartment.
fresh air circulation. Controls in the flight
compartment permit selection of temperature and flow
rates.

21-20-00
- 96 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

FLIGHT COMPARTMENT
DISTRIBUTION PASSENGER COMPARTMENT
DISTRIBUTION
21-20-00-801 Rev 1 06/09/2001

EQUIPMENT COOLING DISTRIBUTION COMPARTMENT

AIR CONDITIONING - DISTRIBUTION - INTRODUCTION

21-20-00
- 97 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- DISTRIBUTION - GENERAL DESCRIPTION
General Recirculation System

The A/C distribution system supplies conditioned air to The recirculation system uses two fans to move air from
the passenger and flight compartments. the passenger compartment to the mix manifold. This
system reduces the amount of air that the packs need to
Main Air Distribution supply.

The main air distribution system gets air from these Ventilation
sources:
The ventilation system uses differential pressure to
- Air conditioning packs pull air out of the airplane. The air moves through
- Ground conditioned air overboard vents from the cabin galley and the lavatory
- Recirculation system. areas.

The mix manifold collects and mixes air from any Equipment Cooling System
combination of the sources.
The equipment cooling system removes heat from the
Flight Compartment Distribution equipment in the main equipment center and the flight
compartment.
The flight compartment gets conditioned air from the
left pack and the mix manifold. A duct on the left side
of the airplane transmits the air. The flight
compartment has supply ducts and outlets to control the
air flow at each station.

Passenger Compartment Distribution


21-20-00-802 Rev 1 03/22/2001

The passenger conditioned air distribution gets air


from the mix manifold. The air goes through riser ducts
and up side walls to an overhead distribution duct.
Outlets along the side walls and the center of the
ceiling divide the air for symmetrical supply.

21-20-00
- 98 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

VENTILATION

OVERHEAD
DISTRIBUTION

PASSENGER AIR
DISTRIBUTION

FLIGHT
COMPARTMENT PACKS (REF)
DISTRIBUTION
21-20-00-802 Rev 1 03/22/2001

MAIN AIR DISTRIBUTION


- MIX MANIFOLD
- GROUND CONDITIONED AIR CONNECTION
RECIRCULATION
SYSTEM
EQUIPMENT
COOLING

AIR CONDITIONING - DISTRIBUTION - GENERAL DESCRIPTION

21-20-00
- 99 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- DISTRIBUTION - OPERATION
General

The controls for the air conditioning distribution


system are on the air conditioning/bleed air controls
panel in the flight compartment.

Recirculation System

The recirculation fans are enabled when you move the


recirculation fan switches to the AUTO position.
Recirculation fan operation depends on air conditioning
pack operation.
21-20-00-803 Rev 1 12/12/1998

21-20-00
- 100 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

b b
DUAL RAM DOOR RAM DOOR
BLEED a FULL OPEN FULL OPEN

L RECIRC FAN R RECIRC FAN


OFF OFF

AUTO AUTO
40 60
OVHT
80
PSI
0 100
TEST
L PACK R PACK
ISOLATION
OFF VALVE OFF
AUTO AUTO
HIGH AUTO HIGH
WING WING
ANTI OPEN ANTI
ICE PACK PACK ICE
a a

WING-BODY TRIP WING-BODY


OVERHEATa OVERHEATa
a a
BLEED BLEED
TRIP OFF TRIP OFF
RESET
OFF OFF
21-20-00-803 Rev 1 03/23/2001

ON ON
1 APU 2
BLEED
AIR CONDITIONING/BLEED AIR
CONTROLS PANEL (P5)

AIR CONDITIONING - DISTRIBUTION - OPERATION

21-20-00
- 101 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- MAIN AIR DISTRIBUTION - INTRODUCTION
General

The two air conditioning packs supply the main


distribution manifold with conditioned air. The main
distribution manifold supplies air to the passenger
compartment through riser ducts and an overhead
distribution manifold. A moisture drain line lets
moisture in the main distribution manifold drain
overboard.

Location

The main air distribution components are in the


distribution compartment aft of the forward cargo
compartment. There are manifolds and ducts along the
sidewalls and above the ceiling area of the passenger
cabin.

Interfaces

The main air distribution subsystem has interfaces with


these sub-subsystems:

- Recirculation system
- Ground conditioned air connector
- Pack conditioned air
21-21-00-801 Rev 1 03/22/2001

- Distribution manifolds and ducts.

21-21-00
- 102 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

OVERHEAD AIR
DISTRIBUTION CONDITIONING
MANIFOLD PACKS (REF)

RISER DUCTS
TO RIGHT
RISER DUCTS

TO LEFT
RISER DUCTS

RECIRCULATION
SYSTEM (REF)
21-21-00-801 Rev 1 06/09/2001

MIX MANIFOLD
(REF)
TO FLIGHT
GROUND CONDITIONED COMPARTMENT
AIR CONNECTOR DISTRIBUTION
DISTRIBUTION (REF)
COMPARTMENT

AIR CONDITIONING - MAIN AIR DISTRIBUTION - INTRODUCTION

21-21-00
- 103 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- MAIN AIR DISTRIBUTION - GROUND CONDITIONED AIR CONNECTOR
Purpose Training Information Point

The ground conditioned air connector lets an external The ground conditioned air connector attaches to the
source of conditioned air supply the airplane air main distribution manifold duct with band clamps. The
conditioning system. connector fitting attaches to the skin of the airplane
with a pressure seal.
Location
A hinge on the duct and the check valve assembly has a
The ground conditioned air connector is in the main spring. The spring holds the check valve open when the
distribution compartment (aft of the forward cargo air conditioning system is off. When the air
compartment). There is an external access panel forward conditioning system is on, the pressure in the manifold
of the air conditioning compartments. causes the check valve to close.

Physical Description Before you install the duct and check valve assembly,
you must do an inspection of the check valve to make
The ground conditioned air connector is a short duct sure the spring holds the check valve open a short
section with a check valve. There are two slotted distance. Adjust the hinge if necessary and do a test
connect holes on the outside fitting for the ground of the check valve for correct operation.
cart hose hook-up. The ground air connection uses a
standard 8 inch bayonet connector.

Check Valve

The check valve is inside the ground conditioned air


connector. It prevents the loss of air through the
connector when the air conditioning system is on. When
21-21-00-802 Rev 1 03/22/2001

you attach the ground cart hose, the check valve moves
out of the air flow path. The ground conditioned air
can flow into the distribution system.

21-21-00
- 104 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

SLOTTED
HOOK-UP
CONNECT
HOLES

TO MAIN
DISTRIBUTION
MANIFOLD EXTERNAL ACCESS PANEL

DUCT
HINGE AND
SPRING ASSEMBLY
21-21-00-802 Rev 1 03/22/2001

CHECK VALVE

GROUND CONDITIONED AIR CONNECTOR


AIR CONDITIONING - MAIN AIR DISTRIBUTION - GROUND CONDITIONED AIR CONNECTOR

21-21-00
- 105 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- FLIGHT COMPARTMENT CONDITIONED AIR DISTRIBUTION - INTRODUCTION
Purpose You can adjust the overhead outlets airflow direction
with a moveable baffle. Airflow cannot be shut off.
The flight compartment conditioned air distribution
system supplies the flight crew with conditioned air. The air distribution supply ducts in the flight
compartment include metering orifices and mufflers. The
General metering orifices control flow. The mufflers decrease
air noise.
The left air conditioning pack supplies the conditioned
air for the flight compartment. The air flows through
ducts that go forward along the left side of the
airplane. The flight compartment distribution uses
different ducts than the passenger compartment
distribution.

The flight compartment receives conditioned air from


the right pack if the left pack is not operational.

The flight compartment distribution lets the flight


crew select a different air temperature than the other
areas of the airplane.

Flight Compartment Distribution

The flight compartment has these captain and first


officer diffusers and outlets:
21-22-00-801 Rev 1 03/22/2001

- Overhead outlets and gasper


- Underseat diffusers
- Foot air diffusers
- Windshield air diffusers
- Individual panel gaspers.

21-22-00
- 106 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

OVERHEAD
OUTLETS
OBSERVER
INDIVIDUAL
AIR OUTLETS

FLIGHT COMPARTMENT
CONDITIONED AIR
SUPPLY DUCT
WINDSHIELD
OUTLETS

FIRST OFFICER
WINDSHIELD AIR/
FOOT OUTLET VALVE
CAPTAIN
WINDSHIELD AIR/
FOOT OUTLET VALVE
21-22-00-801 Rev 1 03/22/2001

SUPPLY
MUFFLER

UNDERSEAT
DIFFUSER
CAPTAIN (TYP)
INDIVIDUAL
GASPER

AIR CONDITIONING - FLIGHT COMPARTMENT CONDITIONED AIR DISTRIBUTION - INTRODUCTION

21-22-00
- 107 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- FLIGHT COMPT COND AIR DISTRIBUTION - WINDSHIELD AND FOOT AIR OUTLET VALVE
Purpose Training Information Point

The windshield and foot air outlet valves control Adjustment nuts on the control cables adjust the
airflow to the captain and first officer windshield windshield air valve or foot air outlet valve.
outlets and foot outlets.

Location

The windshield outlets are forward of the captain and


first officer glareshield. They supply airflow up and
along the windshield pane. The windshield and foot air
outlet valves are forward of the rudder pedals. The
foot air outlets are inside the captain and first
officer rudder pedal housings.

Physical Description

There are two segmented disks inside the windshield and


foot air outlet valve housing. The disk position
controls airflow from the valve. The segmented disk
connects to the air outlet valve control cable to
change the disk position.

Operation

The captain and first officer windshield and foot air


21-22-00-802 Rev 1 03/22/2001

outlet valves have manual control. The controls are on


the lower portion of the P1 and P3 panels. The controls
are WINDSHIELD AIR and FOOT AIR. They attach to push-
pull control cables. The control cables turn the
segmented disks inside the valves. You pull the knob to
open the valve.

21-22-00
- 108 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

GASPER
AIR OUTLET
(REF)

WINDSHIELD
AIR CONTROL
CAPTAIN AND FIRST OFFICER
WINDSHIELD AIR AND FOOT AIR
CONTROLS (P1 AND P3) FOOT AIR
CONTROL
TO WINDSHIELD
DIFFUSER

WINDSHIELD
VALVE TAB
AIR OUTLET VALVE
CONTROL CABLES

TO RUDDER
PEDAL HOUSING
FOOT
VALVE
21-22-00-802 Rev 1 03/22/2001

TAB

CONDITIONED
AIR
WINDSHIELD AND FOOT AIR OUTLET
VALVE AND CONTROL CABLES
AIR CONDITIONING - FLIGHT COMPT COND AIR DISTRIBUTION - WINDSHIELD AND FOOT AIR OUTLET VALVE

21-22-00
- 109 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- PASSENGER CABIN CONDITIONED AIR DISTRIBUTION - INTRODUCTION
Purpose The overhead distribution duct connects to flexible
hoses to supply the galleys and the lavatories in the
The passenger cabin conditioned air distribution system front and aft cabin areas.
divides the flow of conditioned air to the passenger
cabin. The passenger cabin exhaust air goes through floor
grilles to the recirculation system or overboard.
General

The passenger cabin conditioned air distribution system


uses these components:

- Sidewall riser ducts


- Overhead distribution ducts
- Plenum/nozzle assemblies
- Flexible hoses
- Sidewall diffuser outlets
- Diffuser/hose assembly.

Conditioned air from the main distribution manifold


flows through sidewall riser ducts. The riser ducts
follow the airplane contour along the right and left
fuselage. The left side has two riser sections, the
right side has one. The riser ducts supply the overhead
distribution ducts.

The overhead distribution ducts are along the top


21-23-00-801 Rev 1 03/22/2001

center of the passenger cabin.

Conditioned air from the overhead distribution ducts


goes to the sidewall diffusers and plenum/nozzle
assemblies through diffuser/hoses and mufflers.

21-23-00
- 110 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

DIFFUSER/HOSE
ASSEMBLIES
(TYP)

OVERHEAD
DISTRIBUTION
DUCTS
OVERHEAD
SIDEWALL DISTRIBUTION
DIFFUSER PLENUM/ DUCTS
OUTLETS NOZZLE
(TYP) ASSEMBLY SIDEWALL
DIFFUSER
OUTLETS

SIDEWALL RISER
DUCTS (TYP)
MAIN
21-23-00-801 Rev 1 06/09/2001

FLOOR
DISTRIBUTION GRILLES
MANIFOLD
(REF)

AIR CONDITIONING - PASSENGER CABIN CONDITIONED AIR DISTRIBUTION - INTRODUCTION

21-23-00
- 111 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- PASSENGER CABIN CONDITIONED AIR DISTRIBUTION - OVERHEAD DISTRIBUTION DUCT
Purpose

The overhead distribution duct divides the supply of


conditioned air to outlets along the center and
sidewalls of the passenger cabin for a symmetrical
balance of airflow.

Location

The overhead distribution duct is in the center ceiling


area of the passenger compartment.

Physical Description

The overhead distribution duct is a cylindrical


composite tube. There are outlets along its length that
attach to riser ducts and flexible sidewall ducts. The
fittings in the area where the sidewall riser ducts
attach permit the attachment of temperature sensors.

The sidewall riser ducts attach on the left and right


sides of the overhead distribution manifold.

Training Information Point

You get access to the overhead distribution duct


21-23-00-802 Rev 1 03/23/2001

through the ceiling panels in the passenger cabin.


Screws attach the diffuser outlet assembly to the
overhead distribution duct. Duct brackets attach the
overhead distribution duct to the ceiling supports.
Diffuser/hose connections on the overhead distribution
duct connect to the sidewall diffusers.

21-23-00
- 112 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

OVERHEAD
DISTRIBUTION
DUCTS (TYP)

OVERHEAD BRACKET
DISTRIBUTION ASSEMBLY
DUCT (TYP) MUFFLER (REF) RISER DUCT TEMPERATURE CEILING
ASSEMBLY CONNECTIONS SENSOR SUPPORTS
(TYP) (TYP) FITTINGS
PLENUM/ (REF)
NOZZLE
ASSEMBLY PASSENGER
OVERHEAD
21-23-00-802 Rev 1 03/23/2001

PLENUM/
DISTRIBUTION NOZZLE
DUCT ASSEMBLY
CEILING BRACKET
FWD PANEL ASSEMBLY
DIFFUSER/HOSE (REF)
CONNECTION (TYP)
OVERHEAD DISTRIBUTION DUCT OVERHEAD DISTRIBUTION DUCT INSTALLATION

AIR CONDITIONING - PASSENGER CABIN CONDITIONED AIR DISTRIBUTION - OVERHEAD DISTRIBUTION DUCT

21-23-00
- 113 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- RECIRCULATION SYSTEM - INTRODUCTION
Purpose

The recirculation system supplies air for ventilation.


The use of cabin air for ventilation decreases the use
of air from the engine bleed system.

General Description

The recirculation system collects cabin air to use with


pack air in the distribution system. The distribution
system supplies air to the passenger compartment area.

The passenger cabin air moves through these


recirculation components:

- Collector shroud
- Air filters
- Fans
- Check valves.

Location

The recirculation components are in the distribution


compartment.

Operation
21-25-00-801 Rev 1 03/22/2001

The recirculation fans are enabled when you move the


RECIRC FAN switches to the AUTO position. Recirculation
fan operation depends on air conditioning pack
operation.

21-25-00
- 114 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

b b
DUAL RAM DOOR RAM DOOR
BLEED FULL OPEN FULL OPEN OVERHEAD
a
DISTRIBUTION
L RECIRC FAN R RECIRC FAN MANIFOLD
(REF)
OFF OFF

AUTO AUTO
40 60
OVHT
80
PSI
0 100
TEST AIRFLOW
L PACK R PACK
ISOLATION
OFF VALVE OFF
AUTO AUTO
HIGH AUTO HIGH
WING WING
ANTI OPEN ANTI
ICE PACK PACK ICE COLLECTOR
a a

WING-BODY TRIP WING-BODY


SHROUD
OVERHEATa OVERHEATa
a a AIR FILTERS
BLEED BLEED
TRIP OFF TRIP OFF
RESET RIGHT
OFF OFF RECIRC FAN
21-25-00-801 Rev 1 03/22/2001

LEFT
ON ON CHECK VALVE RECIRC
1 APU 2 FAN
CHECK
BLEED VALVE
RECIRCULATION SCHEMATIC
AIR CONDITIONING/BLEED AIR
CONTROLS PANEL (P5)

AIR CONDITIONING - RECIRCULATION SYSTEM - INTRODUCTION

21-25-00
- 115 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- RECIRCULATION SYSTEM - RECIRCULATION AIR FILTER
Purpose

The recirculation air filters remove small particles of


material from the air that flows back to the passenger
cabin.

General

The recirculation fan pulls air from the passenger


compartment through a high efficiency particulate air
(HEPA) filter to remove very small particles at the
bacteria and microorganism level.

Location

The recirculation components are in the distribution


bay. The filter is in the filter support. Access to the
filter is through the partition at the aft end of the
forward cargo compartment.
21-25-00-804 Rev 1 03/22/2001

21-25-00
- 116 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

RIGHT RECIRCULATION LEFT RECIRCULATION


FAN FILTERS FAN FILTERS
ACCESS PANEL (NO ACCESS PANEL)

DISTRIBUTION COMPARTMENT
(FORWARD CARGO COMPARTMENT - LOOKING AFT)
21-25-00-804 Rev 1 03/22/2001

HIGH EFFICIENCY
PARTICULATE AIR
(HEPA) FILTER

RECIRCULATION AIR FILTER

AIR CONDITIONING - RECIRCULATION SYSTEM - RECIRCULATION AIR FILTER

21-25-00
- 117 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- RECIRCULATION SYSTEM - RECIRCULATION FAN
Purpose Training Information Point

The recirculation fans increase air flow to the When you install a recirculation fan, make sure the
passenger cabin in the main distribution system. flow arrow on the fan is in the correct direction. The
arrow should point to the distribution manifold.
Location

There are two recirculation fans (left and right) in


the distribution compartment. Access to the fans is
through the partition in the forward cargo compartment.

Physical Description

Each fan has these features:

- Housing
- Mounting flanges
- Electrical connector
- Flow direction placard.

Functional Description

The recirculation fans pull air in from the passenger


cabin and supply it into the main distribution
manifold.
21-25-00-802 Rev 1 03/23/2001

The right recirculation fan pulls in air from the


collector shroud in the forward cargo compartment.
Floor grilles in the passenger compartment permit
airflow into the collector shroud.

The left recirculation fan pulls in air from the


distribution compartment.

21-25-00
- 118 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

HOUSING
MOUNTING
FLANGE

ELECTRICAL
CONNECTOR

FWD CARGO COMPARTMENT


(LOOKING AFT - AFT BULKHEADS REMOVED)

MOUNTING
FLANGE
21-25-00-802 Rev 1 03/23/2001

FAN
BLADES FLOW DIRECTION
PLACARD

RECIRCULATION FAN
(TYPICAL)

AIR CONDITIONING - RECIRCULATION SYSTEM - RECIRCULATION FAN

21-25-00
- 119 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- RECIRCULATION SYSTEM - FAN CHECK VALVE
Purpose

The recirculation fan check valves prevent the flow of


conditioned air out of the main distribution manifold
through the recirculation system.

Location

The recirculation fan check valves are in the


distribution compartment. The check valves are between
the recirculation fan and the main distribution
manifold. Access to the check valves is through the
partition at the aft end of the forward cargo
compartment.

Training Information Point

The recirculation fan check valves use V-band clamps


for installation. Make sure you install the check valve
with the correct flow orientation.
21-25-00-805 Rev 1 10/16/1997

21-25-00
- 120 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

MAIN DISTRIBUTION
MANIFOLD (REF)

RECIRCULATION FAN
CHECK VALVE

VALVE FLAPPERS
RECIRCULATION
FANS (REF)

DISTRIBUTION SYSTEM
(FORWARD CARGO COMPARTMENT)
FLOW
DIRECTION
PLACARD
21-25-00-805 Rev 1 03/23/2001

RECIRCULATION FAN CHECK VALVE

AIR CONDITIONING - RECIRCULATION SYSTEM - FAN CHECK VALVE

21-25-00
- 121 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- RECIRCULATION SYSTEM - RIGHT RECIRCULATION FAN - FUNCTIONAL DESCRIPTION
Functional Description

The recirculation fan operates on 115v ac and control


power is 28v dc.

The cabin air recirc fan relay R331 enables power to


the fan. The relay is controlled by:

- Airplane is on the ground


- RECIRC FAN switch
- Recirculation fan overheat switches in the fan
field coils
- Flow control valve (pack valve) closed and auto
relays.

Usually, the RECIRC FAN switch is in the AUTO position


and the fan overheat switches are closed.

The flow control valve closed and auto relays and


air/ground relay form a logic circuit for the fan relay
R331 and are in the air conditioning accessory units
(ACAU). This logic looks at pack flow conditions. If
one (L or R) of the pack valve closed relays is
energized, the recirculation fan operates to increase
cabin ventilation. If one (L or R) of the pack valves
have their auto relays energized, the recirculation fan
21-25-00-806 Rev 1 03/22/2001

operates.

21-25-00
- 122 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

115V AC
MAIN
BUS 2

AIR CONDITIONING
RECIRC FAN RIGHT
CABIN AIR

AIR CONDITIONING
RECIRC FAN RIGHT
CONT R331 CABIN R CABIN AIR
R AIR RECIRC RECIRC FAN
FAN RELAY
P6 CB PANEL

OPEN OFF/HIGH

CLOSED AUTO
K7 L PACK VALVE K14 L PACK
CLOSED RELAY AUTO RELAY

OFF OPEN OFF/HIGH


21-25-00-806 Rev 1 03/22/2001

AUTO
CLOSED AUTO
R RECIRC AIR
FAN SWITCH K7 R PACK VALVE K14 R PACK
CLOSED RELAY AUTO RELAY
AIR CONDITIONING
PANEL (P5)
GND
K10 AIR/GND RLY
AIR CONDITIONING ACCESSORY UNIT (TYP)

AIR CONDITIONING - RECIRCULATION SYSTEM - RIGHT RECIRCULATION FAN - FUNCTIONAL DESCRIPTION

21-25-00
- 123 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- RECIRCULATION SYSTEM - LEFT RECIRCULATION FAN - FUNCTIONAL DESCRIPTION
Functional Description

The recirculation fan operates on 115v ac and control


power is 28v dc.

The cabin air recirc fan relay R429 enables power to


the fan. The relay is controlled by these functions:

- Airplane is on the ground


- RECIRC FAN switch
- Recirculation fan overheat switches in the fan
field coils
- Flow control valve (pack valve) closed and auto
relays.

Normally the RECIRC FAN switch is in the AUTO position


and the fan overheat switches are closed.

The flow control valve closed and auto relays and


air/ground relay form a logic circuit for the R429 fan
relay and are in the air conditioning accessory units
(ACAU). This logic looks at pack flow conditions. If
one (L or R) of the pack valve closed relays is
energized, the recirculation fan operates to increase
cabin ventilation. If one (L or R) of the pack valves
have their auto relays energized, the recirculation fan
21-25-00-807 Rev 1 01/24/2001

operates.

21-25-00
- 124 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

115V AC
MAIN
BUS 1

AIR CONDITIONING
RECIRC FAN LEFT
CABIN AIR

AIR CONDITIONING
RECIRC FAN LEFT
CONT R429 CABIN L CABIN AIR
L AIR RECIRC RECIRC FAN
FAN RELAY
P6 CB PANEL OPEN OFF/HIGH

CLOSED AUTO
K7 L PACK VALVE K14 L PACK
CLOSED RELAY AUTO RELAY
OFF
OPEN OFF/HIGH

AUTO
CLOSED AUTO
L RECIRC
FAN SWITCH K7 R PACK VALVE K14 R PACK
CLOSED RELAY AUTO RELAY
21-25-00-807 Rev 1 03/23/2001

AIR CONDITIONING
PANEL (P5) AIR

GND
K10 AIR/GND RLY
AIR CONDITIONING ACCESSORY UNIT (TYP)
AIR CONDITIONING - RECIRCULATION SYSTEM - LEFT RECIRCULATION FAN - FUNCTIONAL DESCRIPTION

21-25-00
- 125 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - INTRODUCTION
Purpose

The temperature control system controls the air


temperature in these locations:

- Flight compartment
- Forward passenger compartment
- Aft passenger compartment.

Abbreviations and Acronyms

ACAU - air conditioning accessory unit


auto - automatic
compt - compartment
ctrl - control
dk - deck
EE - electronic equipment
flt - flight
FWD - forward
OVHT - overheat
PASS - passenger
prsov - pressure regulating shutoff valve
ref - reference
STBY - standby
21-60-00-801 Rev 1 02/01/2002

vlv - valve

21-60-00
- 126 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

AFT PASSENGER
COMPARTMENT

FORWARD PASSENGER
COMPARTMENT

FLIGHT
COMPARTMENT
21-60-00-801 Rev 1 02/01/2002

AIR CONDITIONING - TEMPERATURE CONTROL - INTRODUCTION

21-60-00
- 127 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - GENERAL DESCRIPTION
THIS PAGE INTENTIONALLY LEFT BLANK
21-60-00-803 Rev 1 12/13/1999

21-60-00
- 128 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - GENERAL DESCRIPTION
General Description The flight crew selects the temperature setpoints for
the three airplane zones with the temperature
The temperature control system can operate when the air selectors.
conditioning packs operate. The packs operate when
there is a bleed source from the pneumatic system. Pack/Zone Temperature Controllers

The air conditioning accessory units (ACAU) monitor the There are two pack/zone temperature controllers. They
operation logic for the pneumatic and air conditioning monitor system parameters and control the air
systems. It enables the temperature control system when conditioning temperatures for the three air
the air systems are serviceable. conditioning zones.

The pack/zone temperature controllers receive control The pack/zone temperature controllers are part of a
signals from the temperature control panel. Temperature redundant, fault tolerant control system. The system
sensors send temperature data from the flight and reconfigures to give optimum performance when there are
passenger compartments. The pack/zone temperature faults.
controllers send control and operation signals through
the ACAU for temperature control. The controllers process inputs from these things:

The temperature control system has overheat switches in - Zone temperature selectors
the supply ducts. The overheat switches give indication - Zone cabin temperature sensors
and stop operation when the temperature is out of - Zone duct temperature sensors
limits. - Pack temperature sensors
- Mix manifold sensors.
Temperature bulbs in the passenger cabin and duct
monitor and send temperature data to the cabin The controllers modulate these valves in response to
temperature control panel. The temperature control temperature control requirements:
21-60-00-803 Rev 1 12/13/1999

panel shows air temperatures.


- Pack temperature control valves (normal and
Temperature Control Panel standby)
- Zone trim air modulating valves.
The temperature control panel is the flight crew
interface for system control and indication.

21-60-00
- 129 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - GENERAL DESCRIPTION
Pack Temperature Control Valves (Normal and Standby) Duct Overheat Switch

The temperature control valves control the discharge The duct overheat switch provides overheat protection
temperature of the air conditioning packs. of the supply ducts. When the supply duct temperature
is 190F (88C), the switch energizes a relay in the
The temperature control valve is the normal valve for ACAU. The relay closes the trim air modulating valve.
control of pack output temperature

The standby temperature control valve does these


functions:

- Controls pack output temperature if the normal


system components fail
- Operates to prevent icing in the condenser.

Trim Air Pressure Regulating and Shutoff Valve

The trim air pressure regulating and shutoff valve does


these functions:

- Controls airflow to the zone trim air modulating


and shutoff valves
- Controls the pressure of the airflow to the zone
trim air modulating valves.

Zone Trim Air Modulating Valves


21-60-00-803 Rev 1 12/13/1999

The zone trim air modulating valves control the trim


air flow to the three air conditioning zones. Hot trim
air goes to the zones that have hotter demands.

21-60-00
- 130 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

RIGHT PACK
RAM AIR ACTUATOR TEMP CONTROL VALVE
R PACK/ZONE RIGHT PACK STBY
CONTROLLER TEMP CONTROL VALVE
RAM AIR
TEMP SENSOR LEFT PACK STBY
TEMP CONTROL VALVE
AFT PASSENGER ZONE
SELECTOR/ZONE TEMP
SENSOR/ZONE DUCT
TEMP SENSOR DUCT
OVERHEAT PACK
DUCT SWITCH TEMP LEFT PACK
OVERHEAT SENSOR TEMP CONTROL
SWITCH MIX VALVE
FWD PASSENGER ZONE MANIFOLD
SELECTOR/ZONE TEMP SENSORS
SENSOR/ZONE DUCT
TEMP SENSOR
DUCT
OVERHEAT
SWITCH

L PACK/ZONE
ZONE TEMP CONTROLLER
SELECTOR AFT PASSENGER ZONE
TRIM AIR MOD VALVE
ZONE TEMP SENSOR TEMPERATURE
CONTROL PANEL
FWD PASSENGER ZONE
21-60-00-803 Rev 1 07/12/1999

ZONE DUCT TEMP (P5)


TRIM AIR MOD VALVE
SENSORS
TRIM AIR PRESSURE
REGULATING AND SHUT
ACAU OFF VALVE
FLT DECK ZONE
TRIM AIR MOD VALVE

AIR CONDITIONING - TEMPERATURE CONTROL - GENERAL DESCRIPTION

21-60-00
- 131 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - OPERATION
General Trim Air Switch

The temperature controls panel is the air conditioning The trim air switch controls the trim air pressure
indication and control interface for the flight crew. regulating and shutoff valve. It has these two
positions:
The temperature controls panel has these features:
- ON - The trim air pressure regulating and shutoff
- Temperature selectors (3) valve opens. Zone trim air channels in pack/zone
- Duct overheat lights (3) controllers are enabled.
- Trim air switch - OFF - The trim air pressure regulating and shutoff
- Temperature indicator valve closes. Zone trim air channels in the
- Air temperature source selector. pack/zone controllers are disabled.

Temperature Selectors Temperature Indicator and Air Temperature Source


Selector
The three temperature selectors give automatic
temperature control for their related zones. The temperature indicator shows the temperature at the
location selected with the air temperature source
The selector has these temperature setpoints: selector. These are the positions:

- C (cool) sets a temperature of 65F (18C) - SUPPLY DUCT - Selects related zone supply duct
- W (warm) sets a temperature of 85F (30C) temperature
- Intermediate selector positions set proportionate - PASS CABIN - Selects FWD or AFT passenger cabin
temperature. temperature
- PACK - Selects water extractor discharge
Turn the selector to the OFF position to close the temperature (pack temperature).
21-60-00-804 Rev 1 12/13/1999

related trim air modulating valve.

ZONE TEMP Light

The three ZONE TEMP lights turn on for overtemperature


or control channel failures.

21-60-00
- 132 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

TEMPERATURE
INDICATOR

AIR TEMP PASS


CAB
120 S FWD
TEMP. 160 U D AFT AFT
AIR TEMP
80 P U F SOURCE
200 P C W R P SELECTOR
L T D A
40
Y C
F CONT L
TRIM AIR CAB K
TRIM AIR OFF
SWITCH
ON

ZONE ZONE ZONE ZONE


TEMP a TEMP a TEMP a TEMP
CONT CAB FWD CAB AFT CAB LIGHTS
21-60-00-804 Rev 1 12/12/1998

AUTO AUTO AUTO


TEMPERATURE
SELECTORS

C W C W C W
OFF OFF OFF
TEMPERATURE CONTROLS PANEL

AIR CONDITIONING - TEMPERATURE CONTROL - OPERATION

21-60-00
- 133 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - CABIN TEMPERATURE SENSOR ASSEMBLY
Purpose Functional Description

The cabin temperature sensor assembly provides a flow The fan pulls in cabin air through the inlet grille and
of filtered air over a cabin temperature sensor and air filter. The cabin temperature sensor elements send
bulb. The cabin temperature sensor provides compartment the air temperature to the pack/zone temperature
temperature data to the pack/zone temperature controllers. The pack/zone temperature controllers use
controllers. this data to compare with the cabin temperature
selectors.
Location
Training Information Point
The flight compartment cabin temperature sensor
assembly is in the ceiling of the flight compartment. You must clean the cabin temperature sensor air filter
regularly.
There are two passenger cabin temperature sensor
assemblies in the right side of the passenger cabin.
They are in the bullnose area of the passenger service
units.

Physical Description

These components are part of the cabin temperature


sensor assembly:

- Cabin temperature sensor


- Inlet grille
- Air filter
21-60-00-817 Rev 1 12/12/1998

- Temperature sensor fan

The cabin temperature sensor has two sensing elements.

21-60-00
- 134 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

TEMPERATURE
SENSOR FAN

AIR FILTER

TEMPERATURE
SENSOR

INLET GRILLE

FLIGHT COMPARTMENT

FLIGHT COMPARTMENT
TEMPERATURE SENSOR ASSEMBLY

TEMPERATURE
SENSOR FAN

TEMPERATURE BULB
(REF)
AIR FILTER TEMPERATURE
21-60-00-817 Rev 1 08/13/2001

SENSOR

INLET GRILLE
FWD
PASSENGER COMPARTMENT
PASSENGER COMPARTMENT - BULLNOSE AREA TEMPERATURE SENSOR ASSEMBLY

AIR CONDITIONING - TEMPERATURE CONTROL - CABIN TEMPERATURE SENSOR ASSEMBLY

21-60-00
- 135 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - DUCT TEMPERATURE SENSOR
Purpose

The duct temperature sensor gives duct temperature


feedback to the pack/zone temperature controllers.

Location

There is a flight compartment duct temperature sensor


and a backup duct temperature sensor. They are in the
distribution bay on the left side.

There is a forward and an aft passenger cabin duct


temperature sensor. The forward cabin duct temperature
sensor is in the overhead duct forward of the left
forward riser. The aft passenger cabin duct temperature
sensor is in the overhead duct aft of the right aft
riser.

Physical Description

The duct temperature sensor is a single element sensor.

Functional Description

The duct temperature sensor sends the duct temperature


to the pack/zone temperature controller. The pack/zone
21-60-00-818 Rev 1 03/13/2000

temperature controller uses this data to compare with a


cabin temperature selector and cabin temperature
sensor.

21-60-00
- 136 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

FWD

PASSENGER CABIN DUCT


TEMPERATURE SENSOR

PASSENGER COMPARTMENT OVERHEAD


DISTRIBUTION DUCT INSTALLATION
(TYPICAL)
21-60-00-818 Rev 1 03/26/2001

FLIGHT COMPARTMENT DUCT


FWD TEMPERATURE SENSOR

FLIGHT COMPARTMENT SUPPLY DUCT


DISTRIBUTION DUCT INSTALLATION

AIR CONDITIONING - TEMPERATURE CONTROL - DUCT TEMPERATURE SENSOR

21-60-00
- 137 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - PACK/ZONE TEMPERATURE CONTROLLER
Purpose - Standby pack temperature control channel
- Ram air actuator control channel.
The pack/zone temperature controllers do these
functions: Training Information Point

- Control their air conditioning pack The pack/zone temperature controllers are electrostatic
- Give automatic standby control to the opposite air discharge sensitive (ESDS) devices. Use ESDS safe
conditioning pack handling techniques.
- Control two zone trim air control channels
- Control their air conditioning pack ram air
actuators
- Provide built-in test equipment (BITE) that
isolates faults to the line replaceable unit
(LRU).

Location

The pack/zone temperature controllers are in the EE


compartment on the E2-3 rack.

General Description

The pack/zone temperature controllers are identical and


interchangeable. Their pin interface with the rack
identifies them to the airplane systems.
21-60-00-813 Rev 1 03/26/2001

Each pack/zone temperature controller has these control


channels:

- Flight compartment zone temperature control


channel
- Passenger cabin zone temperature control channel
- Auto pack temperature control channel

21-60-00
- 138 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

FWD CABIN ZONE AFT CABIN ZONE


TEMP CONTROL TEMP CONTROL

PRIMARY FLT COMPT BACKUP FLT COMPT


ZONE TEMP CONTROL ZONE TEMP CONTROL

R AUTO L AUTO
PACK CONTROL PACK CONTROL
21-60-00-813 Rev 1 03/26/2001

L STANDBY R STANDBY
PACK CONTROL PACK CONTROL

R RAM AIR L RAM AIR


CONTROL CONTROL

RIGHT PACK/ZONE LEFT PACK/ZONE


TEMPERATURE CONTROLLER TEMPERATURE CONTROLLER

AIR CONDITIONING - TEMPERATURE CONTROL - PACK/ZONE TEMPERATURE CONTROLLER

21-60-00
- 139 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - TRIM AIR CHECK VALVE
Purpose

The trim air check valve prevents reverse airflow in


the trim air supply ducts.

Location

There are two trim air check valves. They are in the
right air conditioning compartment.

Physical Description

The trim air check valves are split-flapper type check


valves. They have a flow direction arrow cast into
their flow bodies.

Training Information Point

The trim air check valves are identical and


interchangeable.
21-60-00-815 Rev 1 12/12/1998

21-60-00
- 140 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

FLOW
DIRECTION
RIGHT AIR CONDITIONING COMPARTMENT ARROW
21-60-00-815 Rev 1 03/26/2001

FLAPPER

AIR CONDITIONING - TEMPERATURE CONTROL - TRIM AIR CHECK VALVE

21-60-00
- 141 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - TRIM AIR PRESSURE REGULATING AND SHUTOFF VALVE
Purpose three zone trim air systems are mechanically and
electrically disabled.
The trim air pressure regulating and shutoff valve
controls the flow and pressure of air to the zone trim The valve is spring loaded-closed. When the control
air modulating valves. solenoid is energized, it sends upstream pressure to
the valve actuator. Pressure in the actuator opens the
Location valve. The servo regulator moves the valve to keep
pressure downstream of the valve 4.0 psi above airplane
The trim air pressure regulating and shutoff valve is cabin altitude. This prevents pressure variation due to
in the right air conditioning compartment. various flow demands of the zone trim air modulating
valves.
Physical Description
When the control solenoid de-energizes, it bleeds off
The trim air pressure regulating and shutoff valve is a the actuator pressure. The trim air pressure regulating
modulating and shutoff butterfly-type valve. The valve and shutoff valve spring then pushes the valve closed.
is spring-loaded to the closed position. It is
electrically controlled and pneumatically actuated. Put the TRIM AIR switch to ON to open the trim air
pressure regulating and shutoff valve. This also
The valve has these parts: enables the zone trim air channels in the pack/zone
temperature controllers.
- Solenoid valve assembly
- Actuator assembly Put the TRIM AIR switch to OFF to close the trim air
- Servo regulator assembly pressure regulating and shutoff valve. This also
- Manual override cam and position indicator disables the zone trim air system.
- Electrical connector.
Training Information Point
21-60-00-816 Rev 1 12/12/1998

Functional Description
There is a manual override cam and position indicator
The trim air pressure regulating and shutoff valve is on the trim air pressure regulating and shutoff valve.
the master trim air valve. It supplies trim air to the You can manually turn the valve to the MANUAL CLOSED
three zone trim air modulating valves. If the trim air position. This vents the valve actuator and the valve
pressure regulating and shutoff valve is closed, the closes.

21-60-00
- 142 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

ACTUATOR
ASSEMBLY

RIGHT AIR CONDITIONING COMPARTMENT

SOLENOID VALVE
ASSEMBLY
21-60-00-816 Rev 1 03/26/2001

MANUAL OVERRIDE
AND POSITION
INDICATOR ELECTRICAL
RELIEF VALVE CONNECTOR

SERVO REGULATOR
ASSEMBLY

AIR CONDITIONING - TEMPERATURE CONTROL - TRIM AIR PRESSURE REGULATING AND SHUTOFF VALVE

21-60-00
- 143 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - TRIM AIR PRSOV - FUNCTIONAL DESCRIPTION
Functional Description air to chamber B. When the pressure in chamber B
increases, the trim air PRSOV opens more. When pressure
The trim air pressure regulator and shutoff valve in chamber B decreases, the trim air PRSOV moves toward
(PRSOV) gets unregulated air from the flow control and closed.
shut off valves (FCSOV).
NOTE: The cabin sense port supplies cabin pressure to
The unregulated air goes to these components: the FCSOV to control flow.

- Solenoid valve When you turn the manual override cam assembly, the
- Relief valve manual override cam assembly moves the cam follower to
- Servo regulator (chamber A). close the manual override valve. This will shutoff
unregulated air to these components:
The servo regulator decreases the unregulated air to a
constant control pressure. - Solenoid valve
- Relief valve
The relief valve prevents damage to the pneumatic - Servo regulator.
actuator if the servo regulator fails.

The solenoid valve controls the flow of control air to


chamber B. Control air to chamber B opens the trim air
PRSOV. Air then flows to the downstream sense port.

The downstream sense port supplies bleed air to the


following:

- Chamber C
21-60-00-819 Rev 1 12/12/1998

- Chamber D

Bleed air in chamber C helps the actuator spring


control the trim air PRSOV.

Bleed air in chamber D acts against cabin pressure and


a spring in chamber E. This action controls the control

21-60-00
- 144 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

RIGHT AIR CONDITIONING DISTRIBUTION


CHAMBER E SENSE LINE COMPARTMENT BAY
TO FCSOV

SERVO CABIN
REGULATOR PRESSURE
SENSE PORT
CHAMBER D

CHAMBER B
CHAMBER A

AMBIENT
VENT OPEN
PNEUMATIC
RELIEF VALVE ACTUATOR PRESSURE
BULKHEAD
CLOSED

SOLENOID VALVE
DOWNSTREAM
CHAMBER C
SENSE PORT

AIR FLOW
FROM FCSOV

CAM
21-60-00-819 Rev 1 12/12/1998

FOLLOWER OPEN
MANUAL OVERRIDE
CAM ASSEMBLY

MANUAL OVERRIDE VISUAL POSITION


VALVE INDICATOR PIN
AMBIENT CLOSED
VENT

AIR CONDITIONING - TEMPERATURE CONTROL - TRIM AIR PRSOV - FUNCTIONAL DESCRIPTION

21-60-00
- 145 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - ZONE TRIM AIR MODULATING VALVE
Purpose Functional Description

There are three zone trim air modulating valves. Each The valves use 115v ac. The valve drive signals come
zone valve controls the flow of trim air to its related from the pack zone controllers. A mechanical gear train
air conditioning zone: with a slip clutch gives motor movement to the valve.

- Flight compartment zone Training Information Point


- Forward passenger compartment zone
- Aft passenger compartment zone. There is a position indicator on the zone trim air
modulating valves. The valves are normally in the
Location closed position when the trim air is off.

The flight compartment zone trim air modulating valve You can manually close the valve with the manual
is in the left air conditioning compartment. override knob if the electric motor has a failure. Turn
the knob in the direction shown on the knob placard.
The forward and aft passenger compartment zone trim air
modulating valves are in the right air conditioning
compartment.

Physical Description

The zone trim air modulating valves operate by an


electric motor. The motor moves single plate butterfly
valves. They are the same and interchangeable.

The valves have these parts:


21-60-00-820 Rev 1 12/12/1998

- Electric motor assembly


- Position indicator
- Manual override knob
- Electrical connector.

21-60-00
- 146 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

VALVE
POSITION
INDICATOR
ELECTRIC
MOTOR ASSEMBLY

MANUAL
OVERRIDE
KNOB

ELECTRICAL
CONNECTOR
21-60-00-820 Rev 1 03/29/2001

ZONE TRIM AIR MODULATING VALVE


(TYPICAL)

AIR CONDITIONING - TEMPERATURE CONTROL - ZONE TRIM AIR MODULATING VALVE

21-60-00
- 147 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - FLIGHT COMPARTMENT - FUNCTIONAL DESCRIPTION
THIS PAGE INTENTIONALLY LEFT BLANK
21-60-00-806 Rev 1 03/12/2001

21-60-00
- 148 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - FLIGHT COMPARTMENT - FUNCTIONAL DESCRIPTION
Normal Function Non-Normal Function - Failure

When the trim air switch is in the ON position and the The FAULT and INOP switches are set by these primary
flight compartment temperature selector is in AUTO, the flight compartment failures:
flight compartment trim air modulating valve connects
to the right pack/zone temperature controller. This - Cabin temperature sensor
sends an enable signal to the two controllers to start - Cabin temperature sensor interface
control of the flight compartment temperature. - Duct temperature sensor
- Duct temperature sensor interface
The selected zone temperature goes to the right - Cabin temperature selector
pack/zone temperature controller and is compared with - Cabin temperature selector interface
the actual temperature in the flight compartment. The - Zone trim air modulating valve
difference makes a zone duct temperature demand. It is - Zone trim air modulating valve driver.
limited to 35F to 145F (2C to 63C). This demand is
compared with the actual supply duct temperature and When the FAULT switch is set, K3 relaxes. This connects
the difference is used to move the flight compartment the backup flight compartment zone control to the
trim air modulating valve. flight compartment zone trim air valve. The backup
flight compartment zone control controls the flight
The alternate power relay (K21) suplies electrical compartment trim air modulating valve with the same
power from one of two different sources. When K21 logic as the primary flight compartment zone control.
energizes, 28v dc is from bus 1. When K21 deenergizes,
28v dc is from the battery bus. The backup FAULT switch is set by these backup flight
compartment failures:
Non-Normal Function - System Overheat
- Cabin temperature sensor
When the temperature in the duct is 190F (88C), the - Cabin temperature sensor interface
21-60-00-806 Rev 1 03/12/2001

duct overheat switch closes. This energizes the K6 - Duct temperature sensor
flight deck zone overheat relay to the overheat - Duct temperature sensor interface
position. When K6 is in the overheat position, K4 - Cabin temperature selector
energizes to the close position, and the flight deck - Cabin temperature selector interface
zone trim air modulating valve closes. - Zone trim air modulating valve
- Zone trim air modulating valve driver.

21-60-00
- 149 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - FLIGHT COMPARTMENT - FUNCTIONAL DESCRIPTION
The backup INOP switch is set by these backup flight
compartment failures:

- Cabin temperature sensor


- Cabin temperature sensor interface
- Cabin temperature selector
- Cabin temperature selector interface.

NOTE: Failure of the temperature selector causes a


default to a 75F (24C) set point.

When the primary and backup flight compartment zone


controls fail, the zone temperature control system is
off. This off signal goes to the pack control section
of the pack/zone controllers. The left pack/zone
controller controls the left pack to satisfy the flight
compartment zone duct demand. The right pack/zone
controller controls the right pack to satisfy the
coolest temperature requirements for the passenger
compartments.
21-60-00-806 Rev 1 03/12/2001

21-60-00
- 150 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

115V AC
XFR BUS 2 ZONE TEMP FLIGHT
DECK VLV/FAN OVHT
CONTROL ZONE TEMP LIGHT
28V DC
BAT BUS
A/C VALVES PACK L
P6 CB PANEL
K6 FLT DK
ON ZONE OVHT CLOSE
NORM NORM
OFF
TRIM AIR SW A
AUTO
OPEN
LOGIC SAME AS
OFF RIGHT PACK/ZONE
D CONTROLLER
INOP CLOSE
INOP
BACKUP FLIGHT COMPARTMENT K3 FLT DK
ZONE CONTROL K3 FLT ENABLE
DK INOP INOP
CABIN TEMP K4 FLT DECK
LEFT PACK/ZONE R AIR COND TRIM AIR OFF
SELECTOR CONTROLLER (E2-3) B C D ACCESS UNIT FULL CLOSE
P5 PANEL (E3-2) L AIR COND
ACCESS UNIT
D (E3-2)
FULL OPEN
BACKUP DUCT B
TEMP SENSOR FAULT =
OPEN CLOSE FULL CLOSE
21-60-00-806 Rev 1 03/12/2001

D A BITE VALVE
INOP = OPEN DRIVER
OPEN
INDICATION
CIRCUIT C ZONE TRIM AIR
CABIN TEMP SENSOR MODULATING
LOGIC
PRIMARY FLIGHT COMPARTMENT VALVE
ZONE CONTROL
DUCT TEMP SENSOR RIGHT PACK/ZONE CONTROLLER (E2-3)
AIR CONDITIONING - TEMPERATURE CONTROL - FLIGHT COMPARTMENT - FUNCTIONAL DESCRIPTION

21-60-00
- 151 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - PASSENGER COMPARTMENT - FUNCTIONAL DESCRIPTION
Normal Function Non-Normal Function - System Failure

When the trim air switch is in the ON position and the The FAULT switch is set by these passenger compartment
passenger compartment temperature selector is in AUTO, failures:
the passenger compartment trim air modulating valve
connects to the right pack/zone temperature controller. - Cabin temperature sensor
- Cabin temperature sensor interface
The alternate power relay (K21) supplies electrical - Duct temperature sensor
power from one of two different sources. When K21 - Duct temperature sensor interface
energizes, 28v dc is from bus 1. When K21 deenergizes, - Cabin temperature selector
28v dc is from the battery bus. - Cabin temperature selector interface
- Zone trim air modulating valve
The selected zone temperature goes to the pack/zone - Zone trim air modulating valve driver.
temperature controller and is compared with the actual
temperature in the passenger compartment. The NOTE: Failure of the temperature selector causes a
difference makes a zone duct temperature demand. The default to a 75F (24C) set point.
limits are 35F to 160F (2C to 71C). This demand is
compared with the actual supply duct temperature and These failures cause K11 passenger INOP relay to relax
the difference is used to move the passenger and command the passenger zone trim air modulating
compartment trim air modulating valve. valve to close.

Non-Normal Function - System overheat

When the temperature in the duct is 190F (88C), the


duct overheat switch closes. This energizes K1
passenger zone overheat relay to the overheat position.
21-60-00-807 Rev 1 03/12/2001

When K1 is in the overheat position, K2 passenger trim


air off relay energizes to the close position and the
passenger zone trim air modulating valve closes.

21-60-00
- 152 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
115V AC
XFR BUS 2
ZONE TEMP FWD PASS
VLV/FAN CONT OVHT
28V DC ZONE TEMP LIGHT
BAT BUS
A/C VALVE PACK R
P6 CB PANEL NORM
K1 PASS
ZONE OVHT CLOSE
ON NORM

OFF
TRIM AIR SW OPEN
AUTO ZONE CONT FAULT = OPEN
BITE
ENABLE/OFF
GND = OFF
OFF INOP CLOSE
1 K11 PASS
INOP ENABLE
K2 PASS
TRIM AIR
CABIN TEMP OFF FULL CLOSE
SELECTOR R ACAU
P5 PANEL L (E3-2)
O
G DRIVER FULL OPEN
I
C
21-60-00-807 Rev 1 03/12/2001

DUCT TEMP SENSOR FULL CLOSE

RIGHT PACK/ZONE CONTROLLER


(E2-3) ZONE TRIM AIR
1 MODULATING
VALVE
CABIN TEMP SENSOR
1 BACKUP TO PACK RIGHT STBY TEMP CONTROL IN THE LEFT PACK/ZONE CONTROLLER
AIR CONDITIONING - TEMPERATURE CONTROL - PASSENGER COMPARTMENT - FUNCTIONAL DESCRIPTION

21-60-00
- 153 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - DUCT OVERHEAT SWITCH
Purpose

The duct overheat switch sends an overheat signal to


close the trim air modulating valve. Also, it sends a
signal to turn on the ZONE TEMP light.

Location

The flight compartment duct overheat switch is in the


distribution bay on the left side.

There is a forward and an aft passenger cabin duct


overheat switch. The forward cabin duct overheat switch
is in the overhead duct forward of the left forward
riser. The aft passenger cabin duct overheat switch is
in the overhead duct aft of the right aft riser.

Physical Description

The duct overheat switch is vapor pressure actuated


switch. The duct overheat switch has these parts:

- Probe
- Electrical connector

Functional Description
21-60-00-823 Rev 1 03/27/2001

When the temperature in the duct is 190F (88C), a


liquid in the probe creates a vapor. The vapor in the
probe operates a spring that operates an electrical
switch. This energizes a relay in the air conditioning
accessory unit. The relay turns on the ZONE TEMP light
and closes the trim air modulating valve.

21-60-00
- 154 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

PASSENGER
COMPARTMENT
DUCT OVERHEAT
SWITCH

FWD

PASSENGER COMPARTMENT OVERHEAD


DISTRIBUTION DUCT INSTALLATION
(TYPICAL)
21-60-00-823 Rev 1 03/27/2001

FLIGHT COMPARTMENT DUCT


OVERHEAT SWITCH
FWD
FLIGHT COMPARTMENT SUPPLY DUCT
DISTRIBUTION DUCT INSTALLATION

AIR CONDITIONING - TEMPERATURE CONTROL - DUCT OVERHEAT SWITCH

21-60-00
- 155 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - BALANCED MODE - FUNCTIONAL DESCRIPTION
General Description to control the trim air modulating valves. Also, it is
used in the auto pack controls to control the
The temperature control system controls the temperature temperature control valves.
in three airplane air conditioning zones:
The DUCT DEMAND signal has a 35F(2C) to 145F(63C)
- Flight compartment temperature limit for the flight compartment duct and a
- Forward passenger compartment 35F(2C) to 160F(71C) for the passenger compartment
- Aft passenger compartment. duct. It is compared with the temperature in the duct
and the result is used to control the trim air
The temperature control system is automatic. The flight modulating valves.
crew makes the necessary selections on the temperature
controls panel to operate the system. The DUCT DEMAND signal from the compartment zone
temperature controls are compared in the auto pack
During operation, the pack/zone temperature controllers controls to find the coolest demand of the zones. This
control pack discharge temperature to the requirements signal is called PARTIAL PACK DEMAND. The PARTIAL PACK
of the zone that requires the most cooling. They DEMAND is shared between the two pack/zone temperature
control the temperature control valves to control the controllers and compared to find the coolest signal.
pack discharge temperature. Both packs output the same This signal is called PACK DEMAND and has a 35F(2C) to
temperature. This is called balanced mode. 145F(63C) temperature limit. The PACK DEMAND is used to
control the temperature control valves in each of the
The pack/zone temperature controllers control the trim packs. It is also used as the STANDBY PACK DEMAND
air modulating valves to inject hot trim air into the signal for the other pack in case of a failure. The mix
ducts of the other zones. This increases the manifold temperature sensors provide feedback to the
temperature of the air supply to the three zones. auto pack controls. They are used to prevent ice in the
mix manifold.
Functional Description
21-60-00-821 Rev 1 12/12/1998

In the compartment zone temperature controls, the


pack/zone temperature controllers compare the
compartment temperature selections with the temperature
in the zone. The error signal from this comparison is
called DUCT DEMAND. This signal is used for two
purposes. It is used in the zone temperature controls

21-60-00
- 156 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
FLT COMPT
FLT COMPT TRIM AIR FLT COMPT
MOD VALVE PRI FLT COMPT DUCT
DUCT SENSOR ZONE CTRL FAIL SENSOR
DUCT DEMAND FLT COMPT
FLT COMPT 35F - 145F TEMP
LIMIT DRIVER LOGIC SAME AS
TEMP SENSOR BACKUP FLT COMPT SENSOR
ZONE CONTROL
FLT COMPT FLT COMPT
TEMP SELECTOR PRIMARY FLIGHT TEMP
BACKUP FLT COMPT ZONE CONTROL COMPT ZONE CTRL SELECTOR
AFT PASS COMPT DRIVER FWD PASS
DUCT SENSOR FWD COMPT COMPT DUCT
TRIM AIR LOGIC SAME AS SENSOR
MOD VALVE AFT PASS
DUCT DEMAND 35F - 160F COMPT ZONE
AFT PASS COMPT FWD PASS
TEMP SENSOR LIMIT COMPT TEMP
AFT COMPT SENSOR
TRIM AIR FWD PASSENGER
AFT PASS COMPT ZONE CONTROL MOD VALVE COMPT ZONE CTL FWD PASS
COMPT TEMP
AFT PASS COMPT PARTIAL PACK DEMAND SELECTOR
TEMP SELECTOR COOLEST
DEMAND

COOLEST PACK DEMAND


DEMAND 35F - 145F
LOGIC SAME AS
LEFT AUTO PACK R PACK
RIGHT DIGITAL CTL SENSOR
L PACK SENSOR R TCV
21-60-00-821 Rev 1 12/12/1998

STBY PACK
DEMAND
R MIX
L MIX MANIFOLD COLDEST WARMEST DRIVER MANIFOLD
TEMP SENSOR SIGNAL SIGNAL TEMP
L TCV SENSOR
R AUTO PACK
CONTROL
L AUTO PACK CONTROL
RIGHT PACK/ZONE
LEFT PACK/ZONE TEMPERATURE CONTROLLER TEMPERATURE CONTROLLER
AIR CONDITIONING - TEMPERATURE CONTROL - BALANCED MODE - FUNCTIONAL DESCRIPTION

21-60-00
- 157 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - UNBALANCED MODE - FUNCTIONAL DESCRIPTION
General Description Unbalanced Average Mode

The unbalanced mode is when the flight compartment trim The unbalanced average mode of operation is activated
air system fails or the trim air switch is OFF. if the trim air switch is OFF or if either of the
passenger compartment temperature zones fail.
There are two unbalanced modes of operation:
This mode is the same as the unbalanced mode except for
- Unbalanced the right pack. The right pack is controlled to satisfy
- Unbalanced average. the average temperature requirements of the two
passenger compartment temperature zones.
Unbalanced

The right pack is controlled to satisfy the colder


demand of the two passenger compartment temperature
zones. The left pack is controlled to satisfy only the
temperature requirements of the flight compartment.

The backup flight compartment cabin temperature sensor


and cabin temperature selector provide the pack demand
signal to the left auto pack control.

The backup flight compartment duct temperature sensor


signal is used to provide a 35F(2C) limit in the flight
compartment duct.

The primary flight compartment cabin temperature sensor


21-60-00-822 Rev 1 12/12/1998

and cabin temperature selector provide the standby pack


demand signal to the right auto pack control.

21-60-00
- 158 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

FLT COMPT FLT COMPT


DUCT SENSOR TEMP
SENSOR
BACKUP FLIGHT COMPT PRIMARY FLT
ZONE CONTROL FAILED COMPT ZONE CTRL
FLT COMPT FAILED FLT COMPT
TEMP SENSOR TEMP
SELECTOR
FLT COMPT
TEMP SELECTOR PRIMARY FLIGHT
BACKUP FLT COMPT ZONE CONTROL COMPT ZONE CONTROL
AFT PASS COMPT FWD PASS
DUCT SENSOR DRIVER
LOGIC SAME AS COMPT DUCT
DUCT AFT/FWD AFT PASS SENSOR
DEMAND ZONE FAIL COMPT ZONE
AFT PASS COMPT 35F - 160F
TEMP SENSOR LIMIT FWD PASS
A COMPT TEMP
FWD PASSENGER SENSOR
AFT PASS COMPT ZONE CONTROL COMPT ZONE CTRL
AFT PASS COMPT
TEMP SELECTOR FWD PASS
COMPT TEMP
LEFT SELECTOR
PACK DEMAND COOLEST STBY PACK
35F - 145F DEMAND AVG DEMAND

A LOGIC SAME AS
RIGHT LEFT AUTO PACK R PACK
L PACK SENSOR STBY PACK SENSOR
21-60-00-822 Rev 1 12/12/1998

DIGITAL CTL
DEMAND
L MIX MANIFOLD WARMEST L TCV R TCV
TEMP SENSOR R MIX
SIGNAL DRIVER DRIVER MANIFOLD
TEMP
SENSOR
L AUTO PACK CONTROL R AUTO PACK CONTROL
LEFT PACK/ZONE TEMPERATURE CONTROLLER RIGHT PACK/ZONE TEMP CONTROLLER

AIR CONDITIONING - TEMPERATURE CONTROL - UNBALANCED MODE - FUNCTIONAL DESCRIPTION

21-60-00
- 159 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - ZONE TEMP INDICATION - FUNCTIONAL DESCRIPTION
THIS PAGE INTENTIONALLY LEFT BLANK
21-60-00-809 Rev 1 06/03/1999

21-60-00
- 160 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - ZONE TEMP INDICATION - FUNCTIONAL DESCRIPTION
Purpose master caution system is recalled. This shows that a
BITE check of the controllers is necessary.
The system provides an indication of an overheat
condition in the zone supply ducts or the failure of If there is a complete loss of temperature control for
the temperature control system. the flight compartment, the ZONE TEMP light comes on
immediately and cannot be reset.
Power Interruption
The primary flight compartment INOP switch is set by
Power interruption indication is provided by two power these primary flight compartment failures:
interrupt indication relays, K1 and K2.
- Cabin temperature sensor
If there is a power interruption, the ZONE TEMP light - Cabin temperature sensor interface
on the P5 panel comes on immediately. The zone - Duct temperature sensor
temperature control system is reset after power has - Duct temperature sensor interface
been restored. - Cabin temperature selector
- Cabin temperature selector interface
Overheat Indication - Zone trim air modulating valve
- Zone trim air modulating valve driver.
Overheat protection is provided by overheat switches in
the flight compartment supply duct and in the supply The backup flight compartment INOP switch is set by
ducts for the passenger cabin. these backup flight compartment failures:

If there is an overheat condition, the ZONE TEMP light - Cabin temperature sensor and selector
on the P5 panel comes on immediately. Push the TRIP - Cabin temperature sensor interface and selector
RESET switch on the P5 panel after the duct has cooled - Cabin temperature sensor and selector interface
to reset the zone temperature control system. - Cabin temperature sensor interface and selector
21-60-00-809 Rev 1 06/03/1999

interface.
Flight Compartment Temperature Control System Failure
Indication The backup flight compartment FAULT switch is set by
these backup flight compartment failures:
A failure of the primary or backup flight compartment
temperature control or a malfunction in the system - Cabin temperature sensor
causes the ZONE TEMP light to come on only when the - Cabin temperature sensor interface

21-60-00
- 161 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - ZONE TEMP INDICATION - FUNCTIONAL DESCRIPTION
- Duct temperature sensor - Standby pack-cabin loop electronics.
- Duct temperature sensor interface
- Cabin temperature selector
- Cabin temperature selector interface
- Zone trim air modulating valve
- Zone trim air modulating valve driver.

Passenger Compartment Temperature Control System


Failure Indication

A failure of the passenger zone temperature control


causes the ZONE TEMP light to come on only when the
master caution system is recalled. This shows that a
BITE check of the controllers is necessary.

The passenger compartment FAULT switch is set by these


passenger compartment failures:

- Cabin temperature sensor


- Cabin temperature sensor interface
- Duct temperature sensor
- Duct temperature sensor interface
- Cabin temperature selector
- Cabin temperature selector interface
- Zone trim air modulating valve
- Zone trim air modulating valve driver.
21-60-00-809 Rev 1 06/03/1999

The backup passenger compartment FAULT switch is set by


these backup passenger compartment failures:

- Cabin temperature sensor


- Cabin temperature selector
- Other controller backup error signal output

21-60-00
- 162 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

FLT DECK ZONE


DUCT OVHT
FWD PASS ZONE 190F (88C)
28V DC DUCT OVHT FLT DECK
BAT BUS ZONE DUCT
AIR COND PACK OVHT SW
CONT VALVES TRIP RESET
RIGHT SWITCH
AIR COND PACK K6 FLIGHT
CONT VALVES DECK ZONE
LEFT OVHT RELAY
P6 CB PANEL LEFT ACAU
K1 1 MD&T ZONE TEMP
CONT CABIN ZONE
TEMP LIGHT
190F (88C)
FWD PASS
ZONE DUCT
K2 1 MD&T ZONE TEMP OVHT SW
FWD CABIN ZONE
TEMP LIGHT K1 PASS
ZONE OVHT
P5 PANEL RELAY
BACKUP FLIGHT RIGHT ACAU
COMPT FAULT
GROUND = FAULT
BACKUP FLIGHT FWD PASS COMPT FAULT
COMPT INOP OPEN = FAULT
21-60-00-809 Rev 1 12/12/1998

GROUND = INOP RESET=0 RECALL=1 RECALL=1 RESET=0

BACKUP FWD PASS FLT CONT ELEC ANTI-ICE ENG PRIMARY FLIGHT COMPT INOP
COMPT FAULT FIRE
WARN
MASTER
CAUTION IRS APU HYD OVERHEAD
MASTER
CAUTION
FIRE
WARN
OPEN = INOP
GROUND = FAULT FUEL OVHT/DET DOORS AIR COND

LEFT PACK/ZONE CONTROLLER RIGHT PACK/ZONE CONTROLLER


P7 PANEL NOTE: AFT PASS ZONE SIMILAR
1 POWER INTERRUPT INDICATION RELAYS TO FWD PASS ZONE
AIR CONDITIONING - TEMPERATURE CONTROL - ZONE TEMP INDICATION - FUNCTIONAL DESCRIPTION

21-60-00
- 163 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - PACK LIGHT INDICATION - FUNCTIONAL DESCRIPTION
THIS PAGE INTENTIONALLY LEFT BLANK
21-60-00-810 Rev 1 12/12/1998

21-60-00
- 164 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - PACK LIGHT INDICATION - FUNCTIONAL DESCRIPTION
Purpose Air Conditioning Packs Temperature Control System
Failure indication
The pack light turns on for over temperature
conditions, and failures of the air conditioning A single failure of the pack control system causes the
temperature control system. PACK light to come on only when the master caution
system is recalled. This shows a BITE check of the
Power Interruption controllers is necessary.

Power interruption indication is given by power If a complete loss of temperature control for the pack
interrupt indication relays. control system occurs, the PACK light comes on and
cannot be reset.
If a power interruption is sensed, the PACK light on
the P5 panel comes on. The pack temperature control The standby pack FAULT switch is set by these standby
system is reset after power has been restored. pack component failures:

Over Temperature Indication - Pack temperature sensor


- Temperature control valve
Over temperature protection for the cooling pack is - Pack control.
supplied by these three thermal switches:
The pack INOP and pack FAULT switch is set by these
- Turbine inlet overheat (210F/99C) pack component failures:
- Pack discharge overheat (250F/121C)
- Compressor discharge overheat (390F/198C). - Pack temperature sensor or interface
- Temperature control valve or driver
If an overheat condition is sensed, the PACK light on - Pack control.
the P5 panel comes on. Push the TRIP RESET switch on
21-60-00-810 Rev 1 12/12/1998

the P5 panel after the cooling pack has cooled to reset The pack FAULT switch is set by these pack component
the pack temperature control system. failures:

- Mix manifold temperature sensor or interface


- Mix manifold temperature sensor or interface from
opposite controller

21-60-00
- 165 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - PACK LIGHT INDICATION - FUNCTIONAL DESCRIPTION
- Zone duct demand signal or interface from opposite
controller
- Partial pack demand signal or interface from
opposite controller
- Ram air temperature sensor or interface
- Ram air door actuator or interface.
21-60-00-810 Rev 1 12/12/1998

21-60-00
- 166 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

L PACK/ENG
28V DC BLEED AIR OVHT
BAT BUS
250F (121C)
AIR COND PACK L PACK DISCHARGE
CONT VALVES TRIP RESET OVHT SWITCH
LEFT SWITCH
P6 CB PANEL 210F (99C)
L TURBINE INLET
K1 POWER K8 PACK OVHT SWITCH
INTERRUPT OVHT
INDICATION RLY RELAY
390F (199C)
MD&T PACK L COMP DISCHARGE
LEFT OVHT SWITCH
L PACK LIGHT ACAU
P5 PANEL
BITE
STBY PACK FAULT
GROUND = FAULT

RIGHT PACK/ZONE
TEMPERATURE CONTROLLER

RESET=0 RECALL=1 RECALL=1 RESET=0 PACK INOP


OPEN = INOP
FLT CONT ELEC ANTI-ICE ENG
FIRE MASTER MASTER FIRE
WARN CAUTION IRS APU HYD OVERHEAD CAUTION WARN
21-60-00-810 Rev 1 12/12/1998

FUEL OVHT/DET DOORS AIR COND


BITE
PACK FAULT
OPEN = FAULT
P7 PANEL

NOTE: LEFT PACK LIGHT INDICATION SYSTEM SHOWN LEFT PACK/ZONE


RIGHT PACK LIGHT INDICATION SYSTEM SIMILAR TEMPERATURE CONTROLLER
AIR CONDITIONING - TEMPERATURE CONTROL - PACK LIGHT INDICATION - FUNCTIONAL DESCRIPTION

21-60-00
- 167 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - TEMPERATURE BULB
Purpose - The right air conditioning pack on the right high
pressure water separator assembly
The temperature bulbs measure temperature in the - The left air conditioning pack on the left high
critical areas of the air conditioning system. The pressure water separator assembly.
temperature bulbs are for indication only and are not
part of the automatic temperature control system. Training Information Point

Physical Description Handle the temperature bulbs gently. Use approved


cleaning materials to clean the temperature bulbs.
The temperature bulb has these parts:

- Sensing element
- Electrical connector.

Location

There are seven temperature bulbs in the system. They


are similar in design and operation. There are
temperature bulbs in these locations:

- The flight compartment air conditioning duct in


the distribution bay on the left hand side
- The forward passenger cabin air conditioning
supply duct in the overhead, forward of the left
hand forward riser
- The aft passenger cabin air conditioning supply
21-60-00-825 Rev 1 03/26/2001

duct in the overhead, aft of the right hand aft


riser
- The forward passenger cabin forward right side of
the passenger cabin bullnose area
- The aft passenger cabin aft right side of the
passenger cabin bullnose area

21-60-00
- 168 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL

TEMPERATURE AIR TEMPERATURE


INDICATOR SOURCE SELECTOR SENSING
ELEMENT

AIR TEMP PASS


CAB
120 S FWD
TEMP.160 AFT AFT
U D
80
P U F
200 P C W ELECTRICAL
R P
40 L T D CONNECTOR
F A
Y L C
CONT
TRIM AIR CAB K
OFF

ON
TEMPERATURE CONTROLS PANEL
21-60-00-825 Rev 1 03/19/1999

AIR CONDITIONING - TEMPERATURE CONTROL - TEMPERATURE BULB

21-60-00
- 169 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details