B Ata 21
B Ata 21
S C H O O L O F A E R O N A U T I C S
B 737-400
CAPITULOS ATA 21
21-00-00
- 1 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- INTRODUCTION
Purpose
- Distribution
- Pressurization
- Equipment cooling
- Heating
- Cooling
- Temperature control.
F - Fahrenheit
PZC - pack/zone temperature controller
TCV - temperature control valve
FLT COMPT - flight compartment
21-00-00
- 2 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING
21-00-00
- 3 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- GENERAL DESCRIPTION
General Cabin Pressure Controller
These flight compartment panels let you control the air The cabin pressure controllers control the cabin
conditioning system: pressure function of the air conditioning system.
21-00-00
- 4 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR TEMP
PASS
FWD CAB
AFT
AFT
TEMP S
U D F
P U W C
P C D
L T P
Y CONT L A
CAB C
K
TRIM AIR
OFF
ON
ZONE ZONE ZONE
TEMP TEMP TEMP
C W C W C W
OFF OFF OFF
CABIN TEMPERATURE
PANEL (P5)
DUAL
BLEED
RAM DOOR
FULL OPEN
RAM DOOR
FULL OPEN PACK/ZONE TEMPERATURE AIR CONDITIONING AIR CONDITIONING PACK
RECIRC FAN
OFF
AUTO
RECIRC FAN
OFF
AUTO
CONTROLLER (2) ACCESSORY UNIT (2)
OVHT
AIR
L PACK R PACK
TEST
TEMPERATURE
OFF
AUTO
HIGH
ISOLATION
VALVE
OFF
AUTO
HIGH
DATA
OPEN
TRIP
RESET
OFF OFF
ON ON
1 APU 2
BLEED
AUTO OFF SCHED
FAIL DESCENT ALTN MANUAL
0
ALT
HORN V
A
2
9
50
CABIN CUTOUT L
FLT ALT
SUPPLY EXHAUST
40 ALT
35
5 V
E
30
C
21-00-00-803 Rev 1 03/21/2001
5
6 ALTN
AUTO MAN
LAND ALT
PRESS DIFF
LIMIT: TAKE- 1 2
OFF & LDG .5
3
OFF OFF .125 PSI UP
a a 0 4
DN
3
EQUIPMENT COOLING .5 CAB ALT LAND ALT 2000 4000 6000 8000
2
1 FLT ALT
<FL160 FL220 FL260 FL320 FL410
PANEL (P5)
EE COOLING SYSTEM CABIN PRESSURE
CONTROL PANEL (P5)
AIR CONDITIONING - GENERAL DESCRIPTION
21-00-00
- 5 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- CONTROL PANELS
General - Pack reset.
Cabin Temperature Panel These controls and indication are on the cabin pressure
control panel:
These controls and indications are on the cabin
temperature panel: - Landing altitude selector
- Flight altitude selector
- Control cabin temperature control - Mode selector
- Forward cabin temperature control - Outflow valve position indicator
- Aft cabin temperature control - Manual control toggle switch.
- Trim air switch
- Temperature indication and selection Cabin Altitude Panel
- Duct overheat indication.
These controls and indications are on the cabin
Air Conditioning/Bleed Air Controls Panel altitude panel:
21-00-00-802 Rev 1 04/22/1999
21-00-00
- 6 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR TEMP
CABIN PASS
CAB
TEMPERATURE 120
TEMP. 160
S
U
FWD
AFT
D AFT
P5 FORWARD PANEL 80 P
P
U F
200 C
L W R
OVERHEAD PANEL 40 Y
T
D P
A
F CONT L
CAB C
TRIM AIR K
OFF
ON
EQUIP COOLING C W C W C W
OFF OFF OFF
SUPPLY EXHAUST
DUAL
NORM BLEED
RAM DOOR
FULL OPEN
RAM DOOR
FULL OPEN
30 E CLOSE
3 AUTO AUTO
EQUIPMENT COOLING 8
25
X 1000 FEET 10 C
L O HIGH AUTO HIGH
PANEL 20 15
4
O
S
P
E
7 E N WING WING
PACK OPEN PACK
ANTI TRIP OFF TRIP OFF ANTI
6 5 ICE ICE
21-00-00-802 Rev 1 03/21/2001
ALTN
AUTO MAN WING-BODY TRIP WING-BODY
LAND ALT OVERHEAT OVERHEAT
PRESS DIFF
LIMIT: TAKE- 1 BLEED BLEED
2 TRIP OFF TRIP OFF
OFF & LDG .5
.125 PSI 3
UP RESET
0 4 OFF OFF
DN
3 CAB ALT LAND ALT 2000 4000 6000 8000 ON ON
.5
1
2
FLT ALT 1 APU 2
<FL160 FL220 FL260 FL320 FL410 BLEED
21-00-00
- 7 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COMPONENT LOCATION
Distribution Pressurization
The distribution system has these components in the The pressurization system has components in these areas
distribution compartment (aft of the forward cargo of the airplane:
compartment):
- Flight compartment
- Main distribution manifold - EE compartment
- Recirculation fans - Aft cargo compartment.
- Ground conditioned air connection.
Cooling System
Temperature Control
21-00-00
- 8 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
PASSENGER
DISTRIBUTION
AIR
CONDITIONING
PACKS
CONTROLS AND
INDICATIONS
21-00-00-805 Rev 1 03/27/2001
(P5)
FLIGHT MAIN
COMPARTMENT DISTRIBUTION
DISTRIBUTION MANIFOLD
FORWARD EE COMPARTMENT
EQUIPMENT
COMPARTMENT
AIR CONDITIONING - COMPONENT LOCATION
21-00-00
- 9 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- FUNCTIONAL DESCRIPTION
THIS PAGE INTENTIONALLY LEFT BLANK
21-00-00-804 Rev 1 03/21/2001
21-00-00
- 10 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- FUNCTIONAL DESCRIPTION
General Usually, the left and right flow control systems
provide the same quantity of fresh air. Fresh air flow
These are the primary parts of the air conditioning changes when airplane conditions change.
(A/C) system that have an effect on the supply of fresh
air or the recirculation of conditioned air: Pack Cooling System
- Pack flow control This part of the A/C system removes water as necessary
- Pack cooling system and controls the temperature of the fresh air before it
- Zone temperature control flows into the air distribution part of the air
- Recirculation conditioning system. The primary components are the
- Air distribution. left and right packs.
The primary parts of the A/C system have these The usual control for the left pack makes sure that it
functions: supplies air at a temperature that gives the necessary
cooling for the flight compartment.
- Control fresh air flow for airplane pressurization
and ventilation The control for the right pack makes sure that it
- Control the flight compartment and passenger cabin supplies air at a temperature that gives the necessary
temperature cooling for the mix manifold.
- Recirculate cabin air for ventilation.
Zone Temperature Control
Pack Flow Control
This part of the A/C system increases the temperature
This part of the A/C system controls the quantity of of the conditioned air that flows into the occupied
fresh air that flows into the airplane. The control is areas of the airplane. It also gives pressure
by a flow control and shutoff valve. regulation and on/off control for the trim air part of
21-00-00-804 Rev 1 03/21/2001
21-00-00
- 11 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- FUNCTIONAL DESCRIPTION
The system calculates the necessary pack outlet - Mix manifold
temperatures to satisfy the cooling needs to the flight - Distribution ducts/risers.
compartment and the mix manifold. The system also
calculates the heating necessary for each temperature
control zone. These are the temperature control zones:
Recirculation
Air Distribution
21-00-00
- 12 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
PRESSURE
BULKHEAD
RIGHT
RECIRCULATION RIGHT
SYSTEM COOLING
PACK
AFT
PASSENGER
ZONE
MIX
MANIFOLD
21-00-00-804 Rev 1 03/21/2001
EQUIPMENT
COOLING LEFT
COOLING
PACK
21-00-00
- 13 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- PACK/ZONE TEMPERATURE CONTROLLER - BITE
THIS PAGE INTENTIONALLY LEFT BLANK
21-00-00-806 Rev 1 06/29/1999
21-00-00
- 14 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- PACK/ZONE TEMPERATURE CONTROLLER - BITE
Purpose BITE Test Switches
The pack/zone temperature controllers have front face The pack/zone temperature controller has these
BITE that isolates system faults to the LRU interface switches:
level.
- PRESS/TEST
General Description - BIT
- PREV FLT
The BITE circuitry can detect failures of these - VERIFY
components: - RESET.
21-00-00
- 15 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- PACK/ZONE TEMPERATURE CONTROLLER - BITE
The VERFIY switch starts a real time test of the pack
and zone temperature control components.
BITE Indications
21-00-00
- 16 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
BITE INSTRUCTION
1 IF CONTROLLER FAULT LAMP ON REPLACE IF RED,REPLACE UNIT INDICATED AND PRESS
CONTROLLER VERIFY IF ANY FLT DECK OR ZONE RED LAMP ON
2 AT FLIGHT DECK IDENTIFY AS FOLLOWS
Ñ ALL BLEED SWITCHES OFF LAMP
____ LH CONT
_______ RH CONT
_______
Ñ ZONE TEMP SELECTORS AUTO
Ñ LH AND RH PACK SWITCHES AUTO FLT DECK BACKUP PRIMARY
Ñ TRIM AIR SWITCH ON ZONE AFT ZONE FWD ZONE PRESS/
BKUP ZONE FWD ZONE AFT ZONE
TEST
BIT TEST SWITCHES
3 ON BOTH CONTROLLERS
Ñ LAMP TEST-PUSH PRESS/TEXT. IF ANY LAMP
DOES NOT ILLUMINATE REPLACE Ñ WHEN VERIFY GREEN
CONTROLLER
Ñ PRESS ALL 3 TEST SWITCHES IN SEQUENCE
INDICATED AT EACH POSITION WAIT FOR
4
PRESS RESET
AT FLIGHT DECK LH AND RH AND INDICATORS
PACK SWITCHES OFF
GREEN OR RED LAMP ON
FLT FLT
DECK
DECK OPERATES ONLY
CONTROL WHILE VERIFY
ZONE ZONE SELF-CHECK ON
BKUP
ZONE
MIX MANF
SNSR SENSOR
PACK LAST FLIGHT ACTIVE CLEARS ALL
SNSR MEMORY READOUT PRESENT FAULT NON-VOLATILE
ACT
PACK 1-REGISTER TEST OF ALL LRUS MEMORY REGISTERS
TCV SNSR TCV
OTHER PACK THIS PACK
21-00-00
- 17 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - INTRODUCTION
Purpose
vlv - valve
21-50-00
- 18 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
LEFT RIGHT
TEMPERATURE TEMPERATURE
CONTROL (REF) CONTROL (REF)
21-50-00
- 19 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - GENERAL DESCRIPTION
THIS PAGE INTENTIONALLY LEFT BLANK
21-50-00-802 Rev 1 09/29/2000
21-50-00
- 20 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - GENERAL DESCRIPTION
General Primary Heat Exchanger
The cooling system uses these components and systems to The primary heat exchanger receives bleed air from the
cool the bleed air: flow control and shutoff valve. As the bleed air goes
through the heat exchanger, ram air removes heat. The
- Air conditioning/bleed air controls panel cooled bleed air goes to the compressor section of the
- Flow control and shutoff valve air cycle machine.
- Heat exchangers (2)
- Air cycle machine Air Cycle Machine
- Reheater
- Condenser The air cycle machine is a two wheel, oil lubricated
- Ram air system air cycle machine.
- Water extraction.
Cooled bleed air from the primary heat exchanger enters
Air Conditioning/Bleed Air Controls Panel the air cycle machine where it is compressed. The
compressed air then goes to a secondary heat exchanger,
The air conditioning/bleed air controls panel gives a water separator system and then back to the air cycle
control and indications of the cooling system. These machine where the bleed air is rapidly expanded and
are the controls and indications of the cooling system: sent to a condenser.
21-50-00
- 21 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - GENERAL DESCRIPTION
Condenser
On the ground and in flight with the flaps not up, the
turbofan helps the cooling airflow through the ram air
system.
Water Extraction
21-50-00
- 22 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
b b
DUAL RAM DOOR RAM DOOR
BLEED a FULL OPEN FULL OPEN
AUTO AUTO
PNEUMATIC
40 60
MANIFOLD (REF)
OVHT
80
PSI
0 100
TEST
L PACK R PACK FLOW CONTROL
ISOLATION AND SHUTOFF VALVE
OFF VALVE OFF
AUTO AUTO
HIGH AUTO HIGH
ON ON HEAT EXCHANGERS
1 APU 2
BLEED
RAM AIR SYSTEM
AIR CONDITIONING/BLEED AIR
CONTROLS PANEL (P5)
21-50-00
- 23 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - COMPONENT LOCATION
Component Locations
- Flight compartment
- EE compartment
- Distribution compartment
- Air conditioning compartment and wing-to-body
fairing.
Flight Compartment
EE Compartment
Distribution Compartment
21-50-00
- 24 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING/
BLEED AIR
CONTROLS PANEL
AIR
RAM AIR CONDITIONING
SYSTEM PACKS
FLIGHT COMPARTMENT
FWD
AIR CONDITIONING COMPARTMENT
AND WING-TO-BODY FAIRING
21-50-00-804 Rev 1 09/19/2000
FWD
FWD
DISTRIBUTION COMPARTMENT EE COMPARTMENT
21-50-00
- 25 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - AIR CONDITIONING ACCESSORY UNITS
Purpose - Engine bleed switches
- Duct overheat switches
The air conditioning accessory unit (ACAU) is the - Pneumatic system valves
interface of the airplane operational logic and the air - Air conditioning/bleed air controls panel
systems. - Cabin temperature panel
- Pressurization outflow valve
Location - Recirculation fans
- Forward outflow valve
The ACAUs are in the EE compartment on the E3-2 shelf. - Pneumatic system ovht/ovpress switches
- FMC.
Interfaces
The ACAU sends signals to these components:
The air conditioning accessory unit has an interface
with these systems: - Air conditioning/bleed air controls panel
- Cabin temperature panel
- Flight controls (flaps not up switch) - Bleed air regulators
- Landing gear (air/ground) - Engine start valves
- Engine starting - Pack flow control and shutoff valves
- Air conditioning - Ram air actuators
- Pneumatic/bleed air - Outflow valve
- Flight management computer (FMC). - Recirculation fans
- EE cooling fans
The ACAU receives signals from these airplane - FMC.
components:
Training Information Point
- Engine start valves
21-50-00-809 Rev 1 03/26/2001
- Flap control unit You must do an adjustment/test after you replace the
- Flap up switch ACAU.
- Air/Gnd relays
- Pack flow control and shutoff valve
- Ram air actuators
- Pack overheat switches
- Pack/Zone temperature controller
21-50-00
- 26 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
21-50-00-809 Rev 1 01/21/1999
21-50-00
- 27 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - FLOW CONTROL AND SHUTOFF VALVE - MECHANICAL FUNCTIONAL
Functional Description to maintain the desired flow rate as cabin pressure
decreases. Normal flow mode has an airflow rate of 75
The flow control and shutoff valve is electrically pounds per minute (ppm).
controlled and pneumatically actuated. It is spring-
loaded to the closed position. The valve operates by a When the pack switch is in the HIGH position, solenoid
pneumatic actuator which moves a butterfly plate. When B de-energizes (high flow mode). Actuator air flows to
the pack switch is in the OFF position, 28v dc the APU/high flow servo. The high flow servo has a
energizes solenoid C to the close position. This moves strong bias to close. This will let more air pressure
a ball valve that prevents air pressure from going to go to the valve actuator. This increases airflow. High
the actuator to open the valve. flow mode is 105 ppm.
When the pack switch is in the AUTO or HIGH position, In cruise, if a pack shuts down from an overheat or if
solenoid C receives power to the open coils. The a (L or R) pack switch is OFF, solenoid B de-energizes.
pressurized air flows to the actuator. It pushes This sets the operating pack to high flow mode.
against spring force in the actuator to open the
butterfly plate (valve open). When the valve opens, air The APU high flow mode energizes solenoid A. The APU
flows to the static pressure sense port and the /high flow servo has one more actuating piston than
downstream (total pressure) sense port. high flow. This results in a higher spring-bias to
close the servo. This lets more pressure go to the
The static and total pressure sense ports balance valve actuator. APU/high flow mode has an airflow rate
actuator opening pressure for the auto and high flow of 131 ppm.
servos. These ports permit a measure of differential
pressure in the venturi which corresponds to the rate Training Information Point
of airflow.
A manual control shaft on solenoid C lets you open the
Solenoid B changes flow modes between the normal flow solenoid manually.
21-50-00-807 Rev 1 01/21/1999
21-50-00
- 28 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
APU/HIGH
FLOW SERVO AUTO
FLOW
SERVO
SOLENOID A
MANUAL CABIN
CONTROL PRESSURE
SHAFT SENSE PORT
SOLENOID B
SOLENOID C
INTERNAL
BELLOWS
PILOT
PRESSURE
REGULATOR
ACTUATOR
CLOSE
UPSTREAM
SENSE PORT
AIR STATIC PRESSURE TOTAL PRESSURE
FLOW
21-50-00-807 Rev 1 01/21/1999
AIR CONDITIONING - COOLING - FLOW CONTROL AND SHUTOFF VALVE - MECHANICAL FUNCTIONAL DESCRIPTION
21-50-00
- 29 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - FLOW CONTROL AND SHUTOFF VALVE - ELECTRICAL FUNCTIONAL
Pack Switch OFF - Airplane in the air (the pack air/gnd relay (K10)
goes to the AIR position)
When the pack switch is in the OFF position, 28v dc - Flaps up (the flap not up relay (K19) goes to the
(battery bus) energizes the close coil of solenoid C. UP position).
When the close coil is energized, the flow control and
shutoff valve is closed. When solenoid B deenergizes, the FCSOV operates in the
high flow mode.
Pack Switch AUTO
Pack Switch HIGH
When the pack switch is in the AUTO position, 28v dc
energizes the open coil of solenoid C. When open coil When the switch is in the HIGH position, solenoid B is
of solenoid C is energized, the FCSOV opens. This also deenergized. When solenoid B is deenergized, the FCSOV
moves a position switch to open. The position switch is in the high flow mode.
gives a discrete signal to these systems:
Solenoid A is energized when the all of these
- Flight management computer system conditions are true:
- Pressurization system
- Temperature control system - The pack switch is in the HIGH position
- Recirculation system. - The APU bleed switch is in the ON position
- The APU operates above 95%
When either engine bleed switch is on, 28v dc energizes - The airplane is on the ground.
solenoid B through the low flow mode relay (K18).
When solenoid A is energized the FCSOV operates in the
When solenoid B is energized, the FCSOV operates in the APU high flow mode.
low flow mode.
21-50-00-811 Rev 1 03/26/2001
21-50-00
- 30 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
1
28V DC
BAT BUS
A/C PACK CONT
VALVE RIGHT
CLOSED
28V DC OVHT CLOSE
BAT BUS
A/C PACK CONT C
VALVE LEFT
K8 PACK OPEN
P6 CB PANEL
OFF OVHT RLY
LOW FLOW
AUTO MODE
HIGH B
UP AIR A
AIR
28V DC
L FCSOV
NOT UP GND
95% GND
L PACK SW K19 FLAP K10 PACK
APU CONTROL R275 GND NOT UP AIR/GND
UNIT SENSE RLY OFF OFF RLY RLY
(E11)
ON
ON
ENG BLEED SW L ACAU 1
21-50-00-811 Rev 1 03/26/2001
OFF CLOSED
NOTE: RIGHT PACK FCSOV R FCSOV
CIRCUIT SIMILAR ON
1 PROVIDES A DISCRETE TO APU BLEED
THE FMCS, RECIRC, SW
PRESSURIZATION AND AIR COND/BLEED AIR
TEMP CONTROL SYSTEMS CONTROLS PANEL (P5)
AIR CONDITIONING - COOLING - FLOW CONTROL AND SHUTOFF VALVE - ELECTRICAL FUNCTIONAL DESCRIPTION
21-50-00
- 31 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - HEAT EXCHANGERS
Purpose Training Information Point
The primary heat exchanger (HX) removes heat from bleed The heat exchanger efficiency decreases as dirt and
air going to the compressor section of the air cycle contamination collect on the cooling surfaces. A RAM
machine (ACM). DOOR FULL OPEN light that stays on in flight can be an
indication of a dirty heat exchanger.
The secondary heat exchanger (HX) removes heat from
bleed air that comes from the compressor section of the
air cycle machine (ACM).
Location
Physical Description
Functional Description
21-50-00
- 32 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
SUPPORT
ROD
HEAT EXCHANGER
INLET
FWD
TO ACM
PRIMARY
HEAT EXCHANGER
21-50-00
- 33 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - RAM AIR DUCTS
Purpose ram air inlet duct through the fairing panels. They are
outboard of the air conditioning doors.
The ram air inlet ducts let cooling air flow from the
ram air inlet to the heat exchangers. The ram air A special tool lets you clean the heat exchangers when
exhaust ducts let air flow from the heat exchangers they are dirty.
discharge overboard.
You can repair the ducts if they have cracks or leaks.
Location
Physical Description
21-50-00
- 34 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
RAM AIR
INLET
RAM AIR
INLET DUCT
WING-TO-BODY
FAIRING
ACCESS
PANEL
RAM AIR
EXHAUST DUCT
21-50-00-810 Rev 1 03/26/2001
FWD
RAM AIR
EXIT
LOUVERS
AIR CONDITIONING COMPARTMENT
21-50-00
- 35 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - RAM AIR ACTUATOR
Purpose receives control signals from the pack/zone temperature
controller.
The ram air actuator moves the ram air inlet deflector
door and the ram air inlet modulation panel. Functional Description
Physical Description
- Motor
- Limit switches
- Jackscrew
- Electrical connection.
Interfaces
21-50-00-816 Rev 1 03/26/2001
21-50-00
- 36 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
MOTOR
ELECTRICAL
CONNECTION
JACKSCREW
RAM AIR
INLET
LIMIT
SWITCHES
21-50-00
- 37 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - RAM AIR INLET DOOR ASSEMBLY
Purpose tube with two tie-rods and a preloaded spring. The tie-
rods connect to clevis fittings on the deflector door.
The ram air inlet assembly controls airflow into the
ram air system for heat exchanger cooling. The ram air inlet deflector door makes sure ice, rocks,
and other unwanted material do not go into the ram air
Location inlet.
The ram air inlet assembly is in the wing-to-body The shaft assembly moves the deflector door.
fairing forward of the air conditioning compartments.
Functional Description
Physical Description
The ram air actuator moves the modulation panel. Linear
The ram air inlet assembly has these two major movement of the actuator arm transmits movement through
assemblies: a link arm to the modulation panel shaft assembly. The
shaft turns link arms that lift or lower the two
- Ram air inlet modulation panel panels. The aft panel has rollers that let it move
- Ram air inlet deflector door. forward or aft as the two panels move up or down. The
modulation panel and the ram air inlet deflector door
Ram Air Inlet Modulation Panel are mechanically connected.
The ram air inlet modulation panel is made of two panel The ram air inlet deflector door has two positions.
sections. The two panels are hinged together. The When the airplane is on the ground, the door extends to
forward panel has a hinge at the forward end that give protection to the ram air inlet. When the airplane
connects to the airplane structure. The aft panel has is in the air, the deflector door retracts.
rollers in tracks at the aft end. On the aft panel,
clevis fittings on the mid section and the upper The ram air actuator transmits motion through tie-rods
21-50-00-817 Rev 1 02/14/1999
surface connect link arms to the shaft assembly. and link arms to the shaft assembly. The shaft assembly
transmits motion to the deflector door.
Ram Air Inlet Deflector Door
21-50-00
- 38 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
FORWARD PANEL
DEFLECTOR
ROLLER BULB SEAL
ARM AFT PANEL
TRACK
FAIRING
PANEL
FWD
21-50-00-817 Rev 1 03/27/2001
INLET MODULATION
PANEL QUADRANT
RIGGING PIN
CABLES FROM
RAM AIR
RAM AIR INLET ACTUATOR
21-50-00
- 39 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - RAM AIR EXHAUST MODULATION LOUVER ASSEMBLY
Purpose
Physical Description
21-50-00
- 40 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
EXHAUST
AIR FLOW
LINKAGE
TORQUE SHAFT
INPUT
21-50-00-829 Rev 1 01/26/1999
FWD
21-50-00
- 41 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - RAM AIR SYSTEM - MECHANICAL FUNCTIONAL DESCRIPTION
Functional Description
21-50-00
- 42 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
RAM AIR
EXHAUST
FWD
RAM AIR TORQUE
INLET SHAFT
CONTROL
CABLES
RAM AIR
ACTUATOR
TORQUE
SHAFT
QUADRANT
FWD
AFT
FWD PANEL
CRANK
PANEL
ROLLER
CONTROL
DEFLECTOR CABLES
EXTENSION ARM ASSEMBLY
LINK
CONTROL
CABLES
21-50-00
- 43 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - RAM AIR TEMPERATURE SENSOR
Purpose
Location
There is a ram air sensor for each pack ram air system.
Physical Description
Functional Description
21-50-00
- 44 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
21-50-00
- 45 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - TURBOFAN CONTROL VALVE
Purpose
location
Physical Description
21-50-00
- 46 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
ACTUATOR
ELECTRICAL
CONNECTOR
SOLENOID
ELECTRICAL
CONNECTOR
LIMIT SWITCH
AND INDICATOR
21-50-00
- 47 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - TURBOFAN CONTROL VALVE - MECHANICAL FUNCTIONAL DESCRPTION
Functional Description
21-50-00
- 48 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
BLEED OFF
MANUAL REGULATOR
OVERRIDE
28V DC
LATCHING
SOLENOID
CLOSED
POSITION SENSING
STOP SELECTOR
21-50-00-832 Rev 1 01/26/1999
FILTER TO TURBOFAN
CAVITY AIR FLOW
CLOSED
LIMIT TO
SWITCH RAM AIR
CONTROL
AIR CONDITIONING - COOLING - TURBOFAN CONTROL VALVE - MECHANICAL FUNCTIONAL DESCRPTION
21-50-00
- 49 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - TURBOFAN CONTROL VALVE - ELECTRICAL FUNCTIONAL DESCRIPTION
Functional Description
21-50-00
- 50 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
28V DC
BAT 1 CLOSE
TURBOFAN
VALVE
1 NOT UP
MACH TRIM AIR CONDITIONING ACCESSORY UNIT AIR
FLAP SW R320 GND
E11 SHELF
NOTE: LEFT SYSTEM SHOWN,
RIGHT SYSTEM SIMILAR.
1 RIGHT SYSTEM USES STALL WARN SW
21-50-00
- 51 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - TURBOFAN
Purpose
Location
Physical Description
measure the oil level. There is one oil sump drain plug
on the bottom of the turbofan. If the oil level is
below the fill line on the dipstick, servicing should
be done. Oil servicing is through the dipstick port.
The oil sump holds 500cc of oil.
21-50-00
- 52 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
TURBOFAN
FWD
21-50-00-834 Rev 1 01/26/1999
FLEXIBLE
DUCT
RAM AIR
EXHAUST SUMP DRAIN
TURBOFAN PLUG
21-50-00
- 53 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - RAM AIR SYSTEM - FUNCTIONAL DESCRIPTION
THIS PAGE INTENTIONALLY LEFT BLANK
21-50-00-835 Rev 1 03/26/2001
21-50-00
- 54 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - RAM AIR SYSTEM - FUNCTIONAL DESCRIPTION
General The K16 ram air actuator disable relay is energized.
This removes the left pack zone controller from the ram
The ram air system controls the air flow through the air inlet actuator.
primary and secondary heat exchangers. These are the
ram air control components: There is 115v ac that goes through these relay contacts
to supply a retract signal to the left ram air
- Pack/zone temperature controller actuator:
- Ram air inlet actuator
- Ram air control temperature sensor - Ram BITE enable (K15 - NORMAL)
- Ram air inlet deflector door - Ram mod control (K5 - OPEN)
- Ram air inlet modulation panels - Pack air/ground (K10 - GROUND)
- Ram air ducts. - Ram air actuator disable (K16 - RETRACT).
These are the three modes of control for the ram air The left ram air actuator has internal switches that
system: connect power to the actuator. When the actuator is in
the full retracted position, the modulation panels are
- Ground full open, and the deflector door is extended. The S1
- Flight (flaps not up) switch opens to remove power to the motor.
- Flight cruise (flaps up).
The S3 switch in the ram air actuator connects a ground
The air conditioning accessory unit (ACAU) relays to the air conditioning/bleed air controls panel. This
control power to the pack/zone temperature controller causes the left RAM DOOR FULL OPEN light to come on.
and the ram air inlet actuator.
Flight (Flaps Not Up)
There are different control circuits for the left and
right ram air systems. At takeoff the AIR/GND sensing system opens to
21-50-00-835 Rev 1 03/26/2001
21-50-00
- 55 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - RAM AIR SYSTEM - FUNCTIONAL DESCRIPTION
out of the airstream when the actuator shaft is at the BITE
S2 switch position. The RAM DOOR FULL OPEN light is on.
When BITE is done with the pack/zone temperature
Flight Cruise (Flaps Up) controller, relay K15 energizes. This causes a
simulation of the on-ground position regardless of flap
In flight when the flaps are at a full up position, the position.
K5 relay deenergizes. This deenergizes the K16 relay
and gives the pack/zone controller control of the ram Training Information Point
air inlet actuator.
If the RAM DOOR FULL OPEN light is on during flight
The left turbofan valve closes and the turbofan stops. cruise mode, it can be one of these three possible
problems:
The ram air control circuits in the pack/zone
controller supply command signals to the actuator. The - Ram air system has a blockage
pack/zone controller gets temperature signals from the - Heat exchangers are dirty
ram air sensor. The ram air sensor sends temperature - Electrical failure.
signals from the air cycle machine (ACM) compressor
outlet. The controller uses the air (temperature) NOTE: The left side uses the flaps switch and the right
sensor signal in a bridge circuit. The bridge circuit side uses the stall warning switch.
reads the ACM compressor temperature as an error
signal, too hot or too cold. The nominal (balanced)
control temperature is 230F/110C. The pack/zone
controller opens or closes the ram air inlet modulation
panels to keep this balance.
21-50-00
- 56 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
115V AC POWER IN
XFR AIR COND
BUS 1 RAM AIR
MOD - L
AIR MODULATE
28V DC RETRACT
BUS 1
AIR COND EXTEND
RAM AIR MOD
CONT - L CLOSE
GROUND
28V DC K10 PACK RAM AIR
BAT BUS AIR/GND CONTROL
SENSOR
AIR COND NORMAL RETRACT
PACK CONT
VALVES - L OPEN K16 RAM AIR PACK/ZONE LEFT RAM
K5 RAM MOD ACTUATOR CONTROLLER AIR SENSOR
P6 CB PANEL CTRL DISABLE
GND AIR
K15 RAM BITE
ENABLE RELAY
28V DC TO TF
GND OPEN K7, K5 VALVE
AIR R320
R276
E11 SHELF S2 S3
CLOSE EXTEND
UP (CLOSE)
K7 PACK VALVE
CLOSED RELAY
21-50-00-835 Rev 1 03/26/2001
OPEN CLOSE
NOT UP
FLAPS SW LEFT ACAU RETRACT
(OPEN)
28/16V DC RAM DOOR
MASTER DIM FULL OPEN b S1 S4
SECT 1
A/C PANEL (P5)
P6 CB PANEL LEFT RAM AIR ACTUATOR
AIR CONDITIONING - COOLING - RAM AIR SYSTEM - FUNCTIONAL DESCRIPTION
21-50-00
- 57 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - AIR CYCLE MACHINE
Purpose
Location
Physical Description
- Turbine
- Compressor.
21-50-00
- 58 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
OIL FILLER
PORT (2)
SIGHT
GAUGE (2)
COMPRESSOR
INLET
21-50-00-813 Rev 1 03/26/2001
TURBINE
OUTLET
21-50-00
- 59 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - WATER EXTRACTOR DUCT
Purpose pressure in the extractor forces the water out of the
sump into the drain boss. A line connects the drain
The water extractor duct removes water from the air boss to the water spray nozzle.
conditioning pack ducts.
Location
Physical Description
- Inlet
- Outlet
- Sump
- Drain boss.
Functional Description
21-50-00
- 60 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
SUMP
OUTLET
21-50-00-818 Rev 1 03/26/2001
INLET
21-50-00
- 61 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - REHEATER
Purpose Functional Description
The reheater increases the temperature of the air in The reheater is a a plate-fin, single-pass, crossflow,
the air conditioning pack before it enters the turbine air-to-air heat exchanger. It is made of aluminum.
of the air cycle machine. This increases the efficiency
of the turbine. The reheater is a regenerative-type heat exchanger. It
has these functions:
Location
- Precools the pack air from the secondary heat
There are two reheaters, one for each air conditioning exchanger before it enters the condenser
pack. The reheaters are part of high pressure water - Reheats the pack air as it leaves the water
separator assemblies. These assemblies are in the extractors.
forward area of the air conditioning pack compartments.
Training Information Point
Physical Description - Reheaters
The reheater is part of the high pressure water
The reheaters have these features: separator assembly. To remove the reheater, first
remove the water separator assembly.
- Inlet (hot stream from secondary heat exchanger)
- Outlet (cooled) to condenser You must remove the left air conditioning pack high
- Reheater core case pressure water separator to get access to the center
- Inlets (cold stream from water extractors) fuel tank access panel.
- Outlet (warmed) to air cycle machine turbine
- Pack sensor bosses.
21-50-00
- 62 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
WATER
EXTRACTORS CONDENSER
(REF) (REF)
CORE
CASE
HOT AIR INLET
FROM SECONDARY OUTLET TO
HEAT EXCHANGER AIR CYCLE
MACHINE
TURBINE
OUTLET TO
CONDENSER
SENSOR
BOSS (TYP)
COLD AIR
INLETS FROM
WATER
EXTRACTORS
21-50-00
- 63 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - CONDENSER
Purpose The air cools enough to condense moisture. Part of the
cold air bypasses around the condenser core and warm
The condenser decreases the temperature of the air in air comes through de-icing passages in the face of the
the air conditioning pack to below the dew point. This core to prevent ice on the cold air face of the core. A
causes the water vapor in the airstream to go into a free passage between the two condenser cores is an
liquid form. fail-safe if there is ice.
Functional Description
21-50-00-820 Rev 1 01/21/1999
21-50-00
- 64 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
CONDENSER (REF)
COLD OUTLET
(TO DISTRIBUTION
SYSTEM)
HOT INLET
HOT OUTLET (FROM REHEATER)
(TO WATER ANTI ICE PORT
EXTRACTOR) (FROM COMPRESSOR
DISCHARGE)
COLD INLET
(FROM TURBINE)
STANDBY TCV
DOWNSTREAM
SENSE PORT HOT OUTLET
1 (TO WATER
1 THE UPSTREAM SENSE PORT IS LOCATED ON EXTRACTOR)
THE HOT INLET SIDE OF THE CONDENSER
21-50-00
- 65 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - WATER EXTRACTOR
Purpose The inlet of the water extractor has a swirl chamber to
create a vortex airflow. The water part of the
The water extractors remove water from the air airstream goes into the outer shell of the extractor by
conditioning pack air. centrifugal force. A sump collects the water and
pressure in the extractor forces the water out of the
Location sump into the drain nipples. Lines connect the drain
nipples to the water spray nozzle.
There are four water extractors, two in each air
conditioning pack. The water extractors are part of The water spray nozzle injects the water into the ram
high pressure water separator assemblies. These air duct. This cools the ram air stream by evaporation.
assemblies are in the forward area of the air
conditioning pack compartments.
Physical Description
- Inlet
- Outlet
- Swirl chamber
- Sump
- Water drain nipples.
Functional Description
21-50-00
- 66 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
SWIRL VANES
REHEATER WATER CONDENSER
(REF) EXTRACTORS (REF)
CUTAWAY VIEW
SWIRL
CHAMBER
OUTER
SHELL
INLET
WATER
DRAIN
NIPPLES
AIR CONDITIONING COMPARTMENT
FWD
21-50-00-821 Rev 1 03/26/2001
SUMP
OUTLET
21-50-00
- 67 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - WATER SPRAY NOZZLE
Purpose
Location
There are two water spray nozzles, one for each air
conditioning pack. They are on the outboard bulkhead of
the air conditioning compartments.
Physical Description
Functional Description
21-50-00
- 68 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
WATER
INLET
AIR
INLET
21-50-00
- 69 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - HIGH PRESSURE WATER SEPARATOR MIX MUFF
Purpose
Location
Physical Description
Functional Description
21-50-00
- 70 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
MIXED AIR
OUTLET
ACM ANTI-ICING
LINE BOSS
21-50-00
- 71 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - CONDITIONED AIR CHECK VALVE
Purpose
Location
Physical Description
Functional Description
21-50-00-828 Rev 1 01/26/1999
21-50-00
- 72 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
FWD
CLAMPS
21-50-00
- 73 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - PACK TEMPERATURE SENSOR
Purpose
Location
Functional Description
21-50-00
- 74 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
PACK
TEMPERATURE
SENSOR
21-50-00-894 Rev 1 03/26/2001
21-50-00
- 75 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - MIX MANIFOLD TEMPERATURE SENSOR
Purpose
Location
Functional Description
21-50-00
- 76 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
MIX MANIFOLD
TEMPERATURE SENSOR
(2)
21-50-00-893 Rev 1 01/18/1999
21-50-00
- 77 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - TEMPERATURE CONTROL VALVE
Purpose Training Information Point
The temperature control valve is the primary valve to There is a position indicator on the temperature
control the discharge temperature of the air control valve. The valves are normally in the closed
conditioning pack. position when the packs are off.
Location You can manually close the valve with the manual
override knob if the electric motor fails. Turn the
There are two temperature control valves, one for each knob in the direction shown on the knob placard.
air conditioning pack. They are in the air conditioning
compartments.
Physical Description
Functional Description
21-50-00
- 78 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
VALVE
POSITION ELECTRIC
INDICATOR MOTOR
ASSEMBLY
MANUAL
OVERRIDE
AIR CONDITIONING COMPARTMENT KNOB
ELECTRICAL
CONNECTOR
21-50-00-825 Rev 1 03/26/2001
21-50-00
- 79 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - STANDBY TEMPERATURE CONTROL VALVE
Purpose Functional Description
The standby temperature control valve does these The valve is a pneumatically actuated butterfly-type
things: modulating and shutoff valve. It is spring-loaded to
the closed position.
- Gives backup control for the discharge temperature
of the air conditioning pack (normal temperature Control pressure to the actuator opens and modulates
control system failure) the valve. The control pressure source is the upstream
- Increases the temperature of pack discharge air to side of the valve. These valve devices control the
prevent ice formation in the condenser. pressure to the valve actuator:
Two V-band clamps support the valve. There is a position indicator on the standby
temperature control valve. The valve is normally in the
closed position when the pack is off.
21-50-00
- 80 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
DELTA PRESSURE
ELECTROMAGNETIC SERVO CONTROL
CONTROL VALVE ASSEMBLY
ASSEMBLY POSITION
INDICATOR
PNEUMATIC
ACTUATOR
SENSE PORT TO
CONDENSER OUTLET
21-50-00-824 Rev 1 03/26/2001
MOUNTING
FLANGE
FLOW
SENSE PORT TO BODY
CONDENSER INLET
21-50-00
- 81 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - STANDBY TEMPERATURE CONTROL VALVE - FUNCTIONAL DESCRIPTION
Functional Description
21-50-00
- 82 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
CONDITIONED
CONDENSER CONDENSER AIR CHECK VALVE
INLET OUTLET DELTA P
SERVO TURBINE
AMBIENT POPPET AMBIENT MUFF
VENT VENT
LOW PRESSURE
DELTA P
SERVO
REFERENCE FLAPPER
PRESSURE REGULATOR ELECTROMAGNETIC
HIGH PRESSURE SUPPLY CONTROL VALVE
AMBIENT NOZZLE
DELTA P SERVO VENT
AMBIENT
VENT
CHAMBER A
POPPET
VALVE
OPEN
CHAMBER
VENT
RESTRICTOR
PNEUMATIC
ACTUATOR AMBIENT
21-50-00-826 Rev 1 03/26/2001
VENT
INLET
21-50-00
- 83 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - AUTO CONTROL - FUNCTIONAL DESCRIPTION
Functional Description The mix manifold temperature input to the pack/zone
controller is from two sensors on the mix manifold. The
When you put the pack switch to the AUTO/HIGH position, pack/zone temperature controller compares the two
K13 PACK/HIGH relay energizes if the K7 pack valve inputs and uses the coldest signal. The mix manifold
closed relay is open. When K13 is energized, the temperature and the PACK DEMAND are then compared with
pack/zone controller is enabled and the K17 pack a 35F (2C) limit and the controller controls the
temperature control valve inop relay is energized. temperature control valve.
K21 alternate power relay gives two possible sources Open and close limit switches in the temperature
for electrical power. When K21 energizes, it gives 28v control valve provide feedback signals to the pack/zone
dc from bus 1. When K21 de-energizes, it gives 28v dc temperature controllers.
from the battery bus. 28v dc goes to these relays:
When the zone temperature selectors are in the OFF
- K13 pack AUTO/HIGH relay position, the pack/zone temperature controller uses a
- K17 pack TCV INOP relay. fixed 75F (24C) demand to establish the temperature
control of the pack.
The pack/zone temperature controller controls the
position of the temperature control valve. To move the These are the failures that cause the temperature
temperature control valve, the auto pack control in the control valve to close and activate the standby
pack/zone temperature controller compares the temperature control in the opposite controller:
temperature requirements of the three zones. The
pack/zone temperature controller satisfies the - Pack control
temperature requirement of the zone that needs the most - Pack sensor or interface
cooling. The controller uses this temperature - Temperature control valve or driver.
requirement as a PACK DEMAND signal to establish the
temperature output of the pack. The temperature These failures set the pack INOP and FAULT switches.
21-50-00-805 Rev 1 01/31/2001
21-50-00
- 84 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
115V AC OPEN
XFR BUS 1 A OPEN
28V DC L TCV CLOSE
BAT BUS
L PACK CONTROL K15 BITE K7 PACK VALVE
28V DC ENABLE RELAY CLOSED RELAY CLOSE
BUS 1
L PACK VALVE
115V AC K17 PACK TCV
XFR BUS 1 INOP RELAY
L PACK CONTROL
P6 CB PANEL
K8 PACK
OVHT RELAY
AUTO/HIGH
INDICATION
CIRCUIT
LEFT TEMP
LOGIC CONTROL VALVE
B
LEFT AUTO PACK CONTROL ACTIVATE STANDBY
B PACK CONTROL
L PACK TEMP LEFT PACK/ZONE TEMPERATURE CONTROLLER (E2-3)
SENSOR RIGHT PACK/ZONE TEMP
CONTROLLER (E2-3)
AIR CONDITIONING - COOLING - AUTO CONTROL - FUNCTIONAL DESCRIPTION
21-50-00
- 85 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - STANDBY CONTROL - FUNCTIONAL DESCRIPTION
Purpose
Functional Description
21-50-00
- 86 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
28V DC
BAT BUS
L PACK
VALVE AUTO/HIGH OPEN
P6 CB PANEL
CLOSE
OFF K13 PACK
K7 PACK VALVE CLOSED RLY AUTO/HIGH RELAY
L PACK SW (P5)
L AIR COND PACK ENABLE/OFF
1 ACCESS UNIT (E3-2) GND = ENABLE
FAULT
GND = FAULT
PACK
LEFT AUTO DEMAND
FWD PASS COMPT PACK CONTROL BITE
TEMP SENSOR FAULT STANDBY PACK FAULT
GND = FAULT INDICATION CIRCUIT
PACK INOP A STBY
PACK
1 DEMAND AFT PASSENGER COMPT
RIGHT STANDBY INDICATION CIRCUIT
PACK CONTROL RIGHT AUTO PACK CONTROL
60F/ A
L PACK/ZONE RIGHT AUTO
FWD PASS COMPT CONTROLLER (E3-3) 15C
TEMP SELECTOR MIN PACK CONTROL ACTIVATE STBY
FAILURE PACK COMMAND
A
V 60F TO
G 145F DRIVER
LIMIT
1
LEFT STANDBY PACK CONTROL LEFT
AFT PASS COMPT 1 R PACK/ZONE STANDBY
21-50-00-806 Rev 1 03/27/2001
21-50-00
- 87 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - PACK OVERHEAT SWITCHES
Purpose The turbine inlet overheat switch has an operation
temperature of 210F (99C).
These temperature switches monitor the pack for an
overheat condition: The pack discharge overheat switch has an operation
temperature of 250F (121C).
- Compressor discharge overheat switch
- Turbine inlet overheat switch Training Information Point
- Pack discharge overheat switch.
CAUTION: USE TWO WRENCHES WHEN YOU REMOVE/INSTALL THE
Location SWITCH IN/OUT OF THE BOSS. THIS WILL PREVENT
DAMAGE TO THE DUCT.
There is a compressor discharge overheat switch and a
turbine inlet overheat switch in each air conditioning
compartment.
Functional Description
21-50-00-836 Rev 1 01/20/1999
21-50-00
- 88 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
TURBINE INLET
OVERHEAT SWITCH
FWD
PACK DISCHARGE
OVERHEAT SWITCHES (2)
PROBE
PROBE
SWITCH
HOUSING
21-50-00-836 Rev 1 01/20/1999
ELECTRICAL
CONNECTOR
COMPRESSOR DISCHARGE
OVERHEAT SWITCH
FWD
OVERHEAT SWITCH AIR CONDITIONING COMPARTMENT
21-50-00
- 89 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - PACK PROTECTION - FUNCTIONAL DESCRIPTION
Functional Description
21-50-00
- 90 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
250F/121C
TRIP RESET SWITCH
AIR CONDITIONING/BLEED AIR LEFT PACK DISCHARGE
CONTROL PANEL (P5) DUCT OVHT SW
28V DC
BAT BUS
AIR CONDITION
21-50-00-827 Rev 1 03/08/1999
OVERHEAT
OVHT 210F/99C
P6 CB PANEL
K8 LEFT PACK LEFT TURBINE INLET
OVHT RELAY OVERHEAT SWITCH
AIR CONDITIONING
NOTE: LEFT PACK PROTECTION SHOWN. ACCESSORY UNIT
RIGHT PACK SIMILAR.
21-50-00
- 91 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - FUNCTIONAL DESCRIPTION
THIS PAGE INTENTIONALLY LEFT BLANK
21-50-00-803 Rev 1 03/26/2001
21-50-00
- 92 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - FUNCTIONAL DESCRIPTION
Functional Description When the compressed air goes through the secondary heat
exchanger, ram air removes some of the heat. This bleed
The flow control and shutoff valve gets hot bleed air air goes through the water extractor duct and into the
from the pneumatic manifold. The flow control and reheater.
shutoff valve controls the flow of hot bleed air to the
trim air system, primary heat exchanger and to the two Bleed air that leaves the secondary heat exchanger goes
temperature control valves. A hot air connection through the hot side of the reheater. Air that goes
downstream of the FCSOV supplies hot bleed air to the through the reheater the first time is cooled by colder
turbine case. This prevents ice in the turbine case. air from the condenser. The temperature of the bleed
air increases as it goes through the reheater a second
The ram air system controls the flow of ram air to the time and into the turbine section of the air cycle
primary and secondary heat exchangers. These are the machine.
ram air system components:
Air that leaves the turbine goes through the cold side
- Ram air inlet control temperature sensor of the condenser. Air flow from the condenser divides
- Pack/zone temperature controller into two paths, each path goes through a water
- Ram air inlet actuator extractor.
- Ram air inlet deflector door
- Ram air inlet modulation panels The water extractors remove moisture. This moisture
- Ram air exit louvers goes to the water spray nozzle. The water spray nozzle
- Turbofan valve sprays the water into the ram air duct.
- Turbofan.
Part of the cold air bypasses through the condenser
When bleed air goes through the primary heat exchanger, core to prevent ice in the condenser. This supplies
ram air removes some of the heat. This partially cool warm air through deicing passages in the core and by a
bleed air goes to the compressor section of the air mix of hot bleed air into the turbine muff at the cold
21-50-00-803 Rev 1 03/26/2001
cycle machine. air inlet. The standby temperature control valve senses
condenser ice conditions and sends hot bleed air to the
The compressor section increases the pressure and turbine muff.
temperature of the partially cool bleed air. This
compressed air goes to the secondary heat exchanger.
21-50-00
- 93 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- COOLING - FUNCTIONAL DESCRIPTION
Overheat Protection
21-50-00
- 94 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
TCV FCSOV
TO TRIM
AIR
STBY TCV PACK/ZONE
CONTROLLER
CONDITONAL
AIR CHECK VALVE CONDENSER S RAM AIR
ACTUATOR
PACK
DISCHARGE ACM TURBOFAN A
OVHT SW DIFFUSER
WATER
EXTRACTORS PACK
TEMP REHEATER
SENSOR RAM AIR
TURBINE EXIT
OVHT SW LOUVERS
COMPRESSOR PRIMARY
OVHT SW RAM AIR HEAT TURBOFAN
PACK TEMP SENSOR EXCHANGER VALVE
BULB
SECONDARY
21-50-00-803 Rev 1 03/26/2001
21-50-00
- 95 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- DISTRIBUTION - INTRODUCTION
Purpose Passenger Cabin Conditioned Air Distribution
The distribution system has these functions: The passenger compartment has two zones for
independently controlled air temperature. There are
- Divides conditioned air to the three airplane supply ducts that supply a constant flow to all areas.
zones In each zone, the conditioned air goes to these areas:
- Reduces engine bleed requirements
- Removes offensive air from lavatories and galleys - Passenger cabin
- Supplies cooling air to electronic equipment. - Lavatories
- Galleys.
Main Air Distribution
Recirculation System
The main air distribution components send conditioned
air to these zones: The recirculation system permits ventilation of air in
the passenger cabin areas. The recirculation system
- Flight compartment decreases the use of engine bleed air. This enables
- Forward passenger compartment better thrust management and decreases fuel
- Aft passenger compartment. consumption.
- Ground supplied conditioned air Vent ports adjacent to the lavatory and galleys let air
- Air conditioning packs in those areas flow overboard.
- Recirculation system.
Equipment Cooling
Flight Compartment Distribution
21-20-00-801 Rev 1 03/22/2001
21-20-00
- 96 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
FLIGHT COMPARTMENT
DISTRIBUTION PASSENGER COMPARTMENT
DISTRIBUTION
21-20-00-801 Rev 1 06/09/2001
21-20-00
- 97 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- DISTRIBUTION - GENERAL DESCRIPTION
General Recirculation System
The A/C distribution system supplies conditioned air to The recirculation system uses two fans to move air from
the passenger and flight compartments. the passenger compartment to the mix manifold. This
system reduces the amount of air that the packs need to
Main Air Distribution supply.
The main air distribution system gets air from these Ventilation
sources:
The ventilation system uses differential pressure to
- Air conditioning packs pull air out of the airplane. The air moves through
- Ground conditioned air overboard vents from the cabin galley and the lavatory
- Recirculation system. areas.
The mix manifold collects and mixes air from any Equipment Cooling System
combination of the sources.
The equipment cooling system removes heat from the
Flight Compartment Distribution equipment in the main equipment center and the flight
compartment.
The flight compartment gets conditioned air from the
left pack and the mix manifold. A duct on the left side
of the airplane transmits the air. The flight
compartment has supply ducts and outlets to control the
air flow at each station.
21-20-00
- 98 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
VENTILATION
OVERHEAD
DISTRIBUTION
PASSENGER AIR
DISTRIBUTION
FLIGHT
COMPARTMENT PACKS (REF)
DISTRIBUTION
21-20-00-802 Rev 1 03/22/2001
21-20-00
- 99 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- DISTRIBUTION - OPERATION
General
Recirculation System
21-20-00
- 100 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
b b
DUAL RAM DOOR RAM DOOR
BLEED a FULL OPEN FULL OPEN
AUTO AUTO
40 60
OVHT
80
PSI
0 100
TEST
L PACK R PACK
ISOLATION
OFF VALVE OFF
AUTO AUTO
HIGH AUTO HIGH
WING WING
ANTI OPEN ANTI
ICE PACK PACK ICE
a a
ON ON
1 APU 2
BLEED
AIR CONDITIONING/BLEED AIR
CONTROLS PANEL (P5)
21-20-00
- 101 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- MAIN AIR DISTRIBUTION - INTRODUCTION
General
Location
Interfaces
- Recirculation system
- Ground conditioned air connector
- Pack conditioned air
21-21-00-801 Rev 1 03/22/2001
21-21-00
- 102 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
OVERHEAD AIR
DISTRIBUTION CONDITIONING
MANIFOLD PACKS (REF)
RISER DUCTS
TO RIGHT
RISER DUCTS
TO LEFT
RISER DUCTS
RECIRCULATION
SYSTEM (REF)
21-21-00-801 Rev 1 06/09/2001
MIX MANIFOLD
(REF)
TO FLIGHT
GROUND CONDITIONED COMPARTMENT
AIR CONNECTOR DISTRIBUTION
DISTRIBUTION (REF)
COMPARTMENT
21-21-00
- 103 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- MAIN AIR DISTRIBUTION - GROUND CONDITIONED AIR CONNECTOR
Purpose Training Information Point
The ground conditioned air connector lets an external The ground conditioned air connector attaches to the
source of conditioned air supply the airplane air main distribution manifold duct with band clamps. The
conditioning system. connector fitting attaches to the skin of the airplane
with a pressure seal.
Location
A hinge on the duct and the check valve assembly has a
The ground conditioned air connector is in the main spring. The spring holds the check valve open when the
distribution compartment (aft of the forward cargo air conditioning system is off. When the air
compartment). There is an external access panel forward conditioning system is on, the pressure in the manifold
of the air conditioning compartments. causes the check valve to close.
Physical Description Before you install the duct and check valve assembly,
you must do an inspection of the check valve to make
The ground conditioned air connector is a short duct sure the spring holds the check valve open a short
section with a check valve. There are two slotted distance. Adjust the hinge if necessary and do a test
connect holes on the outside fitting for the ground of the check valve for correct operation.
cart hose hook-up. The ground air connection uses a
standard 8 inch bayonet connector.
Check Valve
you attach the ground cart hose, the check valve moves
out of the air flow path. The ground conditioned air
can flow into the distribution system.
21-21-00
- 104 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
SLOTTED
HOOK-UP
CONNECT
HOLES
TO MAIN
DISTRIBUTION
MANIFOLD EXTERNAL ACCESS PANEL
DUCT
HINGE AND
SPRING ASSEMBLY
21-21-00-802 Rev 1 03/22/2001
CHECK VALVE
21-21-00
- 105 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- FLIGHT COMPARTMENT CONDITIONED AIR DISTRIBUTION - INTRODUCTION
Purpose You can adjust the overhead outlets airflow direction
with a moveable baffle. Airflow cannot be shut off.
The flight compartment conditioned air distribution
system supplies the flight crew with conditioned air. The air distribution supply ducts in the flight
compartment include metering orifices and mufflers. The
General metering orifices control flow. The mufflers decrease
air noise.
The left air conditioning pack supplies the conditioned
air for the flight compartment. The air flows through
ducts that go forward along the left side of the
airplane. The flight compartment distribution uses
different ducts than the passenger compartment
distribution.
21-22-00
- 106 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
OVERHEAD
OUTLETS
OBSERVER
INDIVIDUAL
AIR OUTLETS
FLIGHT COMPARTMENT
CONDITIONED AIR
SUPPLY DUCT
WINDSHIELD
OUTLETS
FIRST OFFICER
WINDSHIELD AIR/
FOOT OUTLET VALVE
CAPTAIN
WINDSHIELD AIR/
FOOT OUTLET VALVE
21-22-00-801 Rev 1 03/22/2001
SUPPLY
MUFFLER
UNDERSEAT
DIFFUSER
CAPTAIN (TYP)
INDIVIDUAL
GASPER
21-22-00
- 107 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- FLIGHT COMPT COND AIR DISTRIBUTION - WINDSHIELD AND FOOT AIR OUTLET VALVE
Purpose Training Information Point
The windshield and foot air outlet valves control Adjustment nuts on the control cables adjust the
airflow to the captain and first officer windshield windshield air valve or foot air outlet valve.
outlets and foot outlets.
Location
Physical Description
Operation
21-22-00
- 108 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
GASPER
AIR OUTLET
(REF)
WINDSHIELD
AIR CONTROL
CAPTAIN AND FIRST OFFICER
WINDSHIELD AIR AND FOOT AIR
CONTROLS (P1 AND P3) FOOT AIR
CONTROL
TO WINDSHIELD
DIFFUSER
WINDSHIELD
VALVE TAB
AIR OUTLET VALVE
CONTROL CABLES
TO RUDDER
PEDAL HOUSING
FOOT
VALVE
21-22-00-802 Rev 1 03/22/2001
TAB
CONDITIONED
AIR
WINDSHIELD AND FOOT AIR OUTLET
VALVE AND CONTROL CABLES
AIR CONDITIONING - FLIGHT COMPT COND AIR DISTRIBUTION - WINDSHIELD AND FOOT AIR OUTLET VALVE
21-22-00
- 109 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- PASSENGER CABIN CONDITIONED AIR DISTRIBUTION - INTRODUCTION
Purpose The overhead distribution duct connects to flexible
hoses to supply the galleys and the lavatories in the
The passenger cabin conditioned air distribution system front and aft cabin areas.
divides the flow of conditioned air to the passenger
cabin. The passenger cabin exhaust air goes through floor
grilles to the recirculation system or overboard.
General
21-23-00
- 110 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
DIFFUSER/HOSE
ASSEMBLIES
(TYP)
OVERHEAD
DISTRIBUTION
DUCTS
OVERHEAD
SIDEWALL DISTRIBUTION
DIFFUSER PLENUM/ DUCTS
OUTLETS NOZZLE
(TYP) ASSEMBLY SIDEWALL
DIFFUSER
OUTLETS
SIDEWALL RISER
DUCTS (TYP)
MAIN
21-23-00-801 Rev 1 06/09/2001
FLOOR
DISTRIBUTION GRILLES
MANIFOLD
(REF)
21-23-00
- 111 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- PASSENGER CABIN CONDITIONED AIR DISTRIBUTION - OVERHEAD DISTRIBUTION DUCT
Purpose
Location
Physical Description
21-23-00
- 112 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
OVERHEAD
DISTRIBUTION
DUCTS (TYP)
OVERHEAD BRACKET
DISTRIBUTION ASSEMBLY
DUCT (TYP) MUFFLER (REF) RISER DUCT TEMPERATURE CEILING
ASSEMBLY CONNECTIONS SENSOR SUPPORTS
(TYP) (TYP) FITTINGS
PLENUM/ (REF)
NOZZLE
ASSEMBLY PASSENGER
OVERHEAD
21-23-00-802 Rev 1 03/23/2001
PLENUM/
DISTRIBUTION NOZZLE
DUCT ASSEMBLY
CEILING BRACKET
FWD PANEL ASSEMBLY
DIFFUSER/HOSE (REF)
CONNECTION (TYP)
OVERHEAD DISTRIBUTION DUCT OVERHEAD DISTRIBUTION DUCT INSTALLATION
AIR CONDITIONING - PASSENGER CABIN CONDITIONED AIR DISTRIBUTION - OVERHEAD DISTRIBUTION DUCT
21-23-00
- 113 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- RECIRCULATION SYSTEM - INTRODUCTION
Purpose
General Description
- Collector shroud
- Air filters
- Fans
- Check valves.
Location
Operation
21-25-00-801 Rev 1 03/22/2001
21-25-00
- 114 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
b b
DUAL RAM DOOR RAM DOOR
BLEED FULL OPEN FULL OPEN OVERHEAD
a
DISTRIBUTION
L RECIRC FAN R RECIRC FAN MANIFOLD
(REF)
OFF OFF
AUTO AUTO
40 60
OVHT
80
PSI
0 100
TEST AIRFLOW
L PACK R PACK
ISOLATION
OFF VALVE OFF
AUTO AUTO
HIGH AUTO HIGH
WING WING
ANTI OPEN ANTI
ICE PACK PACK ICE COLLECTOR
a a
LEFT
ON ON CHECK VALVE RECIRC
1 APU 2 FAN
CHECK
BLEED VALVE
RECIRCULATION SCHEMATIC
AIR CONDITIONING/BLEED AIR
CONTROLS PANEL (P5)
21-25-00
- 115 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- RECIRCULATION SYSTEM - RECIRCULATION AIR FILTER
Purpose
General
Location
21-25-00
- 116 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
DISTRIBUTION COMPARTMENT
(FORWARD CARGO COMPARTMENT - LOOKING AFT)
21-25-00-804 Rev 1 03/22/2001
HIGH EFFICIENCY
PARTICULATE AIR
(HEPA) FILTER
21-25-00
- 117 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- RECIRCULATION SYSTEM - RECIRCULATION FAN
Purpose Training Information Point
The recirculation fans increase air flow to the When you install a recirculation fan, make sure the
passenger cabin in the main distribution system. flow arrow on the fan is in the correct direction. The
arrow should point to the distribution manifold.
Location
Physical Description
- Housing
- Mounting flanges
- Electrical connector
- Flow direction placard.
Functional Description
21-25-00
- 118 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
HOUSING
MOUNTING
FLANGE
ELECTRICAL
CONNECTOR
MOUNTING
FLANGE
21-25-00-802 Rev 1 03/23/2001
FAN
BLADES FLOW DIRECTION
PLACARD
RECIRCULATION FAN
(TYPICAL)
21-25-00
- 119 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- RECIRCULATION SYSTEM - FAN CHECK VALVE
Purpose
Location
21-25-00
- 120 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
MAIN DISTRIBUTION
MANIFOLD (REF)
RECIRCULATION FAN
CHECK VALVE
VALVE FLAPPERS
RECIRCULATION
FANS (REF)
DISTRIBUTION SYSTEM
(FORWARD CARGO COMPARTMENT)
FLOW
DIRECTION
PLACARD
21-25-00-805 Rev 1 03/23/2001
21-25-00
- 121 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- RECIRCULATION SYSTEM - RIGHT RECIRCULATION FAN - FUNCTIONAL DESCRIPTION
Functional Description
operates.
21-25-00
- 122 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
115V AC
MAIN
BUS 2
AIR CONDITIONING
RECIRC FAN RIGHT
CABIN AIR
AIR CONDITIONING
RECIRC FAN RIGHT
CONT R331 CABIN R CABIN AIR
R AIR RECIRC RECIRC FAN
FAN RELAY
P6 CB PANEL
OPEN OFF/HIGH
CLOSED AUTO
K7 L PACK VALVE K14 L PACK
CLOSED RELAY AUTO RELAY
AUTO
CLOSED AUTO
R RECIRC AIR
FAN SWITCH K7 R PACK VALVE K14 R PACK
CLOSED RELAY AUTO RELAY
AIR CONDITIONING
PANEL (P5)
GND
K10 AIR/GND RLY
AIR CONDITIONING ACCESSORY UNIT (TYP)
21-25-00
- 123 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- RECIRCULATION SYSTEM - LEFT RECIRCULATION FAN - FUNCTIONAL DESCRIPTION
Functional Description
operates.
21-25-00
- 124 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
115V AC
MAIN
BUS 1
AIR CONDITIONING
RECIRC FAN LEFT
CABIN AIR
AIR CONDITIONING
RECIRC FAN LEFT
CONT R429 CABIN L CABIN AIR
L AIR RECIRC RECIRC FAN
FAN RELAY
P6 CB PANEL OPEN OFF/HIGH
CLOSED AUTO
K7 L PACK VALVE K14 L PACK
CLOSED RELAY AUTO RELAY
OFF
OPEN OFF/HIGH
AUTO
CLOSED AUTO
L RECIRC
FAN SWITCH K7 R PACK VALVE K14 R PACK
CLOSED RELAY AUTO RELAY
21-25-00-807 Rev 1 03/23/2001
AIR CONDITIONING
PANEL (P5) AIR
GND
K10 AIR/GND RLY
AIR CONDITIONING ACCESSORY UNIT (TYP)
AIR CONDITIONING - RECIRCULATION SYSTEM - LEFT RECIRCULATION FAN - FUNCTIONAL DESCRIPTION
21-25-00
- 125 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - INTRODUCTION
Purpose
- Flight compartment
- Forward passenger compartment
- Aft passenger compartment.
vlv - valve
21-60-00
- 126 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AFT PASSENGER
COMPARTMENT
FORWARD PASSENGER
COMPARTMENT
FLIGHT
COMPARTMENT
21-60-00-801 Rev 1 02/01/2002
21-60-00
- 127 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - GENERAL DESCRIPTION
THIS PAGE INTENTIONALLY LEFT BLANK
21-60-00-803 Rev 1 12/13/1999
21-60-00
- 128 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - GENERAL DESCRIPTION
General Description The flight crew selects the temperature setpoints for
the three airplane zones with the temperature
The temperature control system can operate when the air selectors.
conditioning packs operate. The packs operate when
there is a bleed source from the pneumatic system. Pack/Zone Temperature Controllers
The air conditioning accessory units (ACAU) monitor the There are two pack/zone temperature controllers. They
operation logic for the pneumatic and air conditioning monitor system parameters and control the air
systems. It enables the temperature control system when conditioning temperatures for the three air
the air systems are serviceable. conditioning zones.
The pack/zone temperature controllers receive control The pack/zone temperature controllers are part of a
signals from the temperature control panel. Temperature redundant, fault tolerant control system. The system
sensors send temperature data from the flight and reconfigures to give optimum performance when there are
passenger compartments. The pack/zone temperature faults.
controllers send control and operation signals through
the ACAU for temperature control. The controllers process inputs from these things:
The temperature control system has overheat switches in - Zone temperature selectors
the supply ducts. The overheat switches give indication - Zone cabin temperature sensors
and stop operation when the temperature is out of - Zone duct temperature sensors
limits. - Pack temperature sensors
- Mix manifold sensors.
Temperature bulbs in the passenger cabin and duct
monitor and send temperature data to the cabin The controllers modulate these valves in response to
temperature control panel. The temperature control temperature control requirements:
21-60-00-803 Rev 1 12/13/1999
21-60-00
- 129 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - GENERAL DESCRIPTION
Pack Temperature Control Valves (Normal and Standby) Duct Overheat Switch
The temperature control valves control the discharge The duct overheat switch provides overheat protection
temperature of the air conditioning packs. of the supply ducts. When the supply duct temperature
is 190F (88C), the switch energizes a relay in the
The temperature control valve is the normal valve for ACAU. The relay closes the trim air modulating valve.
control of pack output temperature
21-60-00
- 130 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
RIGHT PACK
RAM AIR ACTUATOR TEMP CONTROL VALVE
R PACK/ZONE RIGHT PACK STBY
CONTROLLER TEMP CONTROL VALVE
RAM AIR
TEMP SENSOR LEFT PACK STBY
TEMP CONTROL VALVE
AFT PASSENGER ZONE
SELECTOR/ZONE TEMP
SENSOR/ZONE DUCT
TEMP SENSOR DUCT
OVERHEAT PACK
DUCT SWITCH TEMP LEFT PACK
OVERHEAT SENSOR TEMP CONTROL
SWITCH MIX VALVE
FWD PASSENGER ZONE MANIFOLD
SELECTOR/ZONE TEMP SENSORS
SENSOR/ZONE DUCT
TEMP SENSOR
DUCT
OVERHEAT
SWITCH
L PACK/ZONE
ZONE TEMP CONTROLLER
SELECTOR AFT PASSENGER ZONE
TRIM AIR MOD VALVE
ZONE TEMP SENSOR TEMPERATURE
CONTROL PANEL
FWD PASSENGER ZONE
21-60-00-803 Rev 1 07/12/1999
21-60-00
- 131 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - OPERATION
General Trim Air Switch
The temperature controls panel is the air conditioning The trim air switch controls the trim air pressure
indication and control interface for the flight crew. regulating and shutoff valve. It has these two
positions:
The temperature controls panel has these features:
- ON - The trim air pressure regulating and shutoff
- Temperature selectors (3) valve opens. Zone trim air channels in pack/zone
- Duct overheat lights (3) controllers are enabled.
- Trim air switch - OFF - The trim air pressure regulating and shutoff
- Temperature indicator valve closes. Zone trim air channels in the
- Air temperature source selector. pack/zone controllers are disabled.
- C (cool) sets a temperature of 65F (18C) - SUPPLY DUCT - Selects related zone supply duct
- W (warm) sets a temperature of 85F (30C) temperature
- Intermediate selector positions set proportionate - PASS CABIN - Selects FWD or AFT passenger cabin
temperature. temperature
- PACK - Selects water extractor discharge
Turn the selector to the OFF position to close the temperature (pack temperature).
21-60-00-804 Rev 1 12/13/1999
21-60-00
- 132 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
TEMPERATURE
INDICATOR
C W C W C W
OFF OFF OFF
TEMPERATURE CONTROLS PANEL
21-60-00
- 133 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - CABIN TEMPERATURE SENSOR ASSEMBLY
Purpose Functional Description
The cabin temperature sensor assembly provides a flow The fan pulls in cabin air through the inlet grille and
of filtered air over a cabin temperature sensor and air filter. The cabin temperature sensor elements send
bulb. The cabin temperature sensor provides compartment the air temperature to the pack/zone temperature
temperature data to the pack/zone temperature controllers. The pack/zone temperature controllers use
controllers. this data to compare with the cabin temperature
selectors.
Location
Training Information Point
The flight compartment cabin temperature sensor
assembly is in the ceiling of the flight compartment. You must clean the cabin temperature sensor air filter
regularly.
There are two passenger cabin temperature sensor
assemblies in the right side of the passenger cabin.
They are in the bullnose area of the passenger service
units.
Physical Description
21-60-00
- 134 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
TEMPERATURE
SENSOR FAN
AIR FILTER
TEMPERATURE
SENSOR
INLET GRILLE
FLIGHT COMPARTMENT
FLIGHT COMPARTMENT
TEMPERATURE SENSOR ASSEMBLY
TEMPERATURE
SENSOR FAN
TEMPERATURE BULB
(REF)
AIR FILTER TEMPERATURE
21-60-00-817 Rev 1 08/13/2001
SENSOR
INLET GRILLE
FWD
PASSENGER COMPARTMENT
PASSENGER COMPARTMENT - BULLNOSE AREA TEMPERATURE SENSOR ASSEMBLY
21-60-00
- 135 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - DUCT TEMPERATURE SENSOR
Purpose
Location
Physical Description
Functional Description
21-60-00
- 136 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
FWD
21-60-00
- 137 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - PACK/ZONE TEMPERATURE CONTROLLER
Purpose - Standby pack temperature control channel
- Ram air actuator control channel.
The pack/zone temperature controllers do these
functions: Training Information Point
- Control their air conditioning pack The pack/zone temperature controllers are electrostatic
- Give automatic standby control to the opposite air discharge sensitive (ESDS) devices. Use ESDS safe
conditioning pack handling techniques.
- Control two zone trim air control channels
- Control their air conditioning pack ram air
actuators
- Provide built-in test equipment (BITE) that
isolates faults to the line replaceable unit
(LRU).
Location
General Description
21-60-00
- 138 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
R AUTO L AUTO
PACK CONTROL PACK CONTROL
21-60-00-813 Rev 1 03/26/2001
L STANDBY R STANDBY
PACK CONTROL PACK CONTROL
21-60-00
- 139 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - TRIM AIR CHECK VALVE
Purpose
Location
There are two trim air check valves. They are in the
right air conditioning compartment.
Physical Description
21-60-00
- 140 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
FLOW
DIRECTION
RIGHT AIR CONDITIONING COMPARTMENT ARROW
21-60-00-815 Rev 1 03/26/2001
FLAPPER
21-60-00
- 141 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - TRIM AIR PRESSURE REGULATING AND SHUTOFF VALVE
Purpose three zone trim air systems are mechanically and
electrically disabled.
The trim air pressure regulating and shutoff valve
controls the flow and pressure of air to the zone trim The valve is spring loaded-closed. When the control
air modulating valves. solenoid is energized, it sends upstream pressure to
the valve actuator. Pressure in the actuator opens the
Location valve. The servo regulator moves the valve to keep
pressure downstream of the valve 4.0 psi above airplane
The trim air pressure regulating and shutoff valve is cabin altitude. This prevents pressure variation due to
in the right air conditioning compartment. various flow demands of the zone trim air modulating
valves.
Physical Description
When the control solenoid de-energizes, it bleeds off
The trim air pressure regulating and shutoff valve is a the actuator pressure. The trim air pressure regulating
modulating and shutoff butterfly-type valve. The valve and shutoff valve spring then pushes the valve closed.
is spring-loaded to the closed position. It is
electrically controlled and pneumatically actuated. Put the TRIM AIR switch to ON to open the trim air
pressure regulating and shutoff valve. This also
The valve has these parts: enables the zone trim air channels in the pack/zone
temperature controllers.
- Solenoid valve assembly
- Actuator assembly Put the TRIM AIR switch to OFF to close the trim air
- Servo regulator assembly pressure regulating and shutoff valve. This also
- Manual override cam and position indicator disables the zone trim air system.
- Electrical connector.
Training Information Point
21-60-00-816 Rev 1 12/12/1998
Functional Description
There is a manual override cam and position indicator
The trim air pressure regulating and shutoff valve is on the trim air pressure regulating and shutoff valve.
the master trim air valve. It supplies trim air to the You can manually turn the valve to the MANUAL CLOSED
three zone trim air modulating valves. If the trim air position. This vents the valve actuator and the valve
pressure regulating and shutoff valve is closed, the closes.
21-60-00
- 142 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
ACTUATOR
ASSEMBLY
SOLENOID VALVE
ASSEMBLY
21-60-00-816 Rev 1 03/26/2001
MANUAL OVERRIDE
AND POSITION
INDICATOR ELECTRICAL
RELIEF VALVE CONNECTOR
SERVO REGULATOR
ASSEMBLY
AIR CONDITIONING - TEMPERATURE CONTROL - TRIM AIR PRESSURE REGULATING AND SHUTOFF VALVE
21-60-00
- 143 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - TRIM AIR PRSOV - FUNCTIONAL DESCRIPTION
Functional Description air to chamber B. When the pressure in chamber B
increases, the trim air PRSOV opens more. When pressure
The trim air pressure regulator and shutoff valve in chamber B decreases, the trim air PRSOV moves toward
(PRSOV) gets unregulated air from the flow control and closed.
shut off valves (FCSOV).
NOTE: The cabin sense port supplies cabin pressure to
The unregulated air goes to these components: the FCSOV to control flow.
- Solenoid valve When you turn the manual override cam assembly, the
- Relief valve manual override cam assembly moves the cam follower to
- Servo regulator (chamber A). close the manual override valve. This will shutoff
unregulated air to these components:
The servo regulator decreases the unregulated air to a
constant control pressure. - Solenoid valve
- Relief valve
The relief valve prevents damage to the pneumatic - Servo regulator.
actuator if the servo regulator fails.
- Chamber C
21-60-00-819 Rev 1 12/12/1998
- Chamber D
21-60-00
- 144 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
SERVO CABIN
REGULATOR PRESSURE
SENSE PORT
CHAMBER D
CHAMBER B
CHAMBER A
AMBIENT
VENT OPEN
PNEUMATIC
RELIEF VALVE ACTUATOR PRESSURE
BULKHEAD
CLOSED
SOLENOID VALVE
DOWNSTREAM
CHAMBER C
SENSE PORT
AIR FLOW
FROM FCSOV
CAM
21-60-00-819 Rev 1 12/12/1998
FOLLOWER OPEN
MANUAL OVERRIDE
CAM ASSEMBLY
21-60-00
- 145 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - ZONE TRIM AIR MODULATING VALVE
Purpose Functional Description
There are three zone trim air modulating valves. Each The valves use 115v ac. The valve drive signals come
zone valve controls the flow of trim air to its related from the pack zone controllers. A mechanical gear train
air conditioning zone: with a slip clutch gives motor movement to the valve.
The flight compartment zone trim air modulating valve You can manually close the valve with the manual
is in the left air conditioning compartment. override knob if the electric motor has a failure. Turn
the knob in the direction shown on the knob placard.
The forward and aft passenger compartment zone trim air
modulating valves are in the right air conditioning
compartment.
Physical Description
21-60-00
- 146 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
VALVE
POSITION
INDICATOR
ELECTRIC
MOTOR ASSEMBLY
MANUAL
OVERRIDE
KNOB
ELECTRICAL
CONNECTOR
21-60-00-820 Rev 1 03/29/2001
21-60-00
- 147 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - FLIGHT COMPARTMENT - FUNCTIONAL DESCRIPTION
THIS PAGE INTENTIONALLY LEFT BLANK
21-60-00-806 Rev 1 03/12/2001
21-60-00
- 148 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - FLIGHT COMPARTMENT - FUNCTIONAL DESCRIPTION
Normal Function Non-Normal Function - Failure
When the trim air switch is in the ON position and the The FAULT and INOP switches are set by these primary
flight compartment temperature selector is in AUTO, the flight compartment failures:
flight compartment trim air modulating valve connects
to the right pack/zone temperature controller. This - Cabin temperature sensor
sends an enable signal to the two controllers to start - Cabin temperature sensor interface
control of the flight compartment temperature. - Duct temperature sensor
- Duct temperature sensor interface
The selected zone temperature goes to the right - Cabin temperature selector
pack/zone temperature controller and is compared with - Cabin temperature selector interface
the actual temperature in the flight compartment. The - Zone trim air modulating valve
difference makes a zone duct temperature demand. It is - Zone trim air modulating valve driver.
limited to 35F to 145F (2C to 63C). This demand is
compared with the actual supply duct temperature and When the FAULT switch is set, K3 relaxes. This connects
the difference is used to move the flight compartment the backup flight compartment zone control to the
trim air modulating valve. flight compartment zone trim air valve. The backup
flight compartment zone control controls the flight
The alternate power relay (K21) suplies electrical compartment trim air modulating valve with the same
power from one of two different sources. When K21 logic as the primary flight compartment zone control.
energizes, 28v dc is from bus 1. When K21 deenergizes,
28v dc is from the battery bus. The backup FAULT switch is set by these backup flight
compartment failures:
Non-Normal Function - System Overheat
- Cabin temperature sensor
When the temperature in the duct is 190F (88C), the - Cabin temperature sensor interface
21-60-00-806 Rev 1 03/12/2001
duct overheat switch closes. This energizes the K6 - Duct temperature sensor
flight deck zone overheat relay to the overheat - Duct temperature sensor interface
position. When K6 is in the overheat position, K4 - Cabin temperature selector
energizes to the close position, and the flight deck - Cabin temperature selector interface
zone trim air modulating valve closes. - Zone trim air modulating valve
- Zone trim air modulating valve driver.
21-60-00
- 149 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - FLIGHT COMPARTMENT - FUNCTIONAL DESCRIPTION
The backup INOP switch is set by these backup flight
compartment failures:
21-60-00
- 150 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
115V AC
XFR BUS 2 ZONE TEMP FLIGHT
DECK VLV/FAN OVHT
CONTROL ZONE TEMP LIGHT
28V DC
BAT BUS
A/C VALVES PACK L
P6 CB PANEL
K6 FLT DK
ON ZONE OVHT CLOSE
NORM NORM
OFF
TRIM AIR SW A
AUTO
OPEN
LOGIC SAME AS
OFF RIGHT PACK/ZONE
D CONTROLLER
INOP CLOSE
INOP
BACKUP FLIGHT COMPARTMENT K3 FLT DK
ZONE CONTROL K3 FLT ENABLE
DK INOP INOP
CABIN TEMP K4 FLT DECK
LEFT PACK/ZONE R AIR COND TRIM AIR OFF
SELECTOR CONTROLLER (E2-3) B C D ACCESS UNIT FULL CLOSE
P5 PANEL (E3-2) L AIR COND
ACCESS UNIT
D (E3-2)
FULL OPEN
BACKUP DUCT B
TEMP SENSOR FAULT =
OPEN CLOSE FULL CLOSE
21-60-00-806 Rev 1 03/12/2001
D A BITE VALVE
INOP = OPEN DRIVER
OPEN
INDICATION
CIRCUIT C ZONE TRIM AIR
CABIN TEMP SENSOR MODULATING
LOGIC
PRIMARY FLIGHT COMPARTMENT VALVE
ZONE CONTROL
DUCT TEMP SENSOR RIGHT PACK/ZONE CONTROLLER (E2-3)
AIR CONDITIONING - TEMPERATURE CONTROL - FLIGHT COMPARTMENT - FUNCTIONAL DESCRIPTION
21-60-00
- 151 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - PASSENGER COMPARTMENT - FUNCTIONAL DESCRIPTION
Normal Function Non-Normal Function - System Failure
When the trim air switch is in the ON position and the The FAULT switch is set by these passenger compartment
passenger compartment temperature selector is in AUTO, failures:
the passenger compartment trim air modulating valve
connects to the right pack/zone temperature controller. - Cabin temperature sensor
- Cabin temperature sensor interface
The alternate power relay (K21) supplies electrical - Duct temperature sensor
power from one of two different sources. When K21 - Duct temperature sensor interface
energizes, 28v dc is from bus 1. When K21 deenergizes, - Cabin temperature selector
28v dc is from the battery bus. - Cabin temperature selector interface
- Zone trim air modulating valve
The selected zone temperature goes to the pack/zone - Zone trim air modulating valve driver.
temperature controller and is compared with the actual
temperature in the passenger compartment. The NOTE: Failure of the temperature selector causes a
difference makes a zone duct temperature demand. The default to a 75F (24C) set point.
limits are 35F to 160F (2C to 71C). This demand is
compared with the actual supply duct temperature and These failures cause K11 passenger INOP relay to relax
the difference is used to move the passenger and command the passenger zone trim air modulating
compartment trim air modulating valve. valve to close.
21-60-00
- 152 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
115V AC
XFR BUS 2
ZONE TEMP FWD PASS
VLV/FAN CONT OVHT
28V DC ZONE TEMP LIGHT
BAT BUS
A/C VALVE PACK R
P6 CB PANEL NORM
K1 PASS
ZONE OVHT CLOSE
ON NORM
OFF
TRIM AIR SW OPEN
AUTO ZONE CONT FAULT = OPEN
BITE
ENABLE/OFF
GND = OFF
OFF INOP CLOSE
1 K11 PASS
INOP ENABLE
K2 PASS
TRIM AIR
CABIN TEMP OFF FULL CLOSE
SELECTOR R ACAU
P5 PANEL L (E3-2)
O
G DRIVER FULL OPEN
I
C
21-60-00-807 Rev 1 03/12/2001
21-60-00
- 153 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - DUCT OVERHEAT SWITCH
Purpose
Location
Physical Description
- Probe
- Electrical connector
Functional Description
21-60-00-823 Rev 1 03/27/2001
21-60-00
- 154 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
PASSENGER
COMPARTMENT
DUCT OVERHEAT
SWITCH
FWD
21-60-00
- 155 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - BALANCED MODE - FUNCTIONAL DESCRIPTION
General Description to control the trim air modulating valves. Also, it is
used in the auto pack controls to control the
The temperature control system controls the temperature temperature control valves.
in three airplane air conditioning zones:
The DUCT DEMAND signal has a 35F(2C) to 145F(63C)
- Flight compartment temperature limit for the flight compartment duct and a
- Forward passenger compartment 35F(2C) to 160F(71C) for the passenger compartment
- Aft passenger compartment. duct. It is compared with the temperature in the duct
and the result is used to control the trim air
The temperature control system is automatic. The flight modulating valves.
crew makes the necessary selections on the temperature
controls panel to operate the system. The DUCT DEMAND signal from the compartment zone
temperature controls are compared in the auto pack
During operation, the pack/zone temperature controllers controls to find the coolest demand of the zones. This
control pack discharge temperature to the requirements signal is called PARTIAL PACK DEMAND. The PARTIAL PACK
of the zone that requires the most cooling. They DEMAND is shared between the two pack/zone temperature
control the temperature control valves to control the controllers and compared to find the coolest signal.
pack discharge temperature. Both packs output the same This signal is called PACK DEMAND and has a 35F(2C) to
temperature. This is called balanced mode. 145F(63C) temperature limit. The PACK DEMAND is used to
control the temperature control valves in each of the
The pack/zone temperature controllers control the trim packs. It is also used as the STANDBY PACK DEMAND
air modulating valves to inject hot trim air into the signal for the other pack in case of a failure. The mix
ducts of the other zones. This increases the manifold temperature sensors provide feedback to the
temperature of the air supply to the three zones. auto pack controls. They are used to prevent ice in the
mix manifold.
Functional Description
21-60-00-821 Rev 1 12/12/1998
21-60-00
- 156 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
FLT COMPT
FLT COMPT TRIM AIR FLT COMPT
MOD VALVE PRI FLT COMPT DUCT
DUCT SENSOR ZONE CTRL FAIL SENSOR
DUCT DEMAND FLT COMPT
FLT COMPT 35F - 145F TEMP
LIMIT DRIVER LOGIC SAME AS
TEMP SENSOR BACKUP FLT COMPT SENSOR
ZONE CONTROL
FLT COMPT FLT COMPT
TEMP SELECTOR PRIMARY FLIGHT TEMP
BACKUP FLT COMPT ZONE CONTROL COMPT ZONE CTRL SELECTOR
AFT PASS COMPT DRIVER FWD PASS
DUCT SENSOR FWD COMPT COMPT DUCT
TRIM AIR LOGIC SAME AS SENSOR
MOD VALVE AFT PASS
DUCT DEMAND 35F - 160F COMPT ZONE
AFT PASS COMPT FWD PASS
TEMP SENSOR LIMIT COMPT TEMP
AFT COMPT SENSOR
TRIM AIR FWD PASSENGER
AFT PASS COMPT ZONE CONTROL MOD VALVE COMPT ZONE CTL FWD PASS
COMPT TEMP
AFT PASS COMPT PARTIAL PACK DEMAND SELECTOR
TEMP SELECTOR COOLEST
DEMAND
STBY PACK
DEMAND
R MIX
L MIX MANIFOLD COLDEST WARMEST DRIVER MANIFOLD
TEMP SENSOR SIGNAL SIGNAL TEMP
L TCV SENSOR
R AUTO PACK
CONTROL
L AUTO PACK CONTROL
RIGHT PACK/ZONE
LEFT PACK/ZONE TEMPERATURE CONTROLLER TEMPERATURE CONTROLLER
AIR CONDITIONING - TEMPERATURE CONTROL - BALANCED MODE - FUNCTIONAL DESCRIPTION
21-60-00
- 157 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - UNBALANCED MODE - FUNCTIONAL DESCRIPTION
General Description Unbalanced Average Mode
The unbalanced mode is when the flight compartment trim The unbalanced average mode of operation is activated
air system fails or the trim air switch is OFF. if the trim air switch is OFF or if either of the
passenger compartment temperature zones fail.
There are two unbalanced modes of operation:
This mode is the same as the unbalanced mode except for
- Unbalanced the right pack. The right pack is controlled to satisfy
- Unbalanced average. the average temperature requirements of the two
passenger compartment temperature zones.
Unbalanced
21-60-00
- 158 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
A LOGIC SAME AS
RIGHT LEFT AUTO PACK R PACK
L PACK SENSOR STBY PACK SENSOR
21-60-00-822 Rev 1 12/12/1998
DIGITAL CTL
DEMAND
L MIX MANIFOLD WARMEST L TCV R TCV
TEMP SENSOR R MIX
SIGNAL DRIVER DRIVER MANIFOLD
TEMP
SENSOR
L AUTO PACK CONTROL R AUTO PACK CONTROL
LEFT PACK/ZONE TEMPERATURE CONTROLLER RIGHT PACK/ZONE TEMP CONTROLLER
21-60-00
- 159 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - ZONE TEMP INDICATION - FUNCTIONAL DESCRIPTION
THIS PAGE INTENTIONALLY LEFT BLANK
21-60-00-809 Rev 1 06/03/1999
21-60-00
- 160 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - ZONE TEMP INDICATION - FUNCTIONAL DESCRIPTION
Purpose master caution system is recalled. This shows that a
BITE check of the controllers is necessary.
The system provides an indication of an overheat
condition in the zone supply ducts or the failure of If there is a complete loss of temperature control for
the temperature control system. the flight compartment, the ZONE TEMP light comes on
immediately and cannot be reset.
Power Interruption
The primary flight compartment INOP switch is set by
Power interruption indication is provided by two power these primary flight compartment failures:
interrupt indication relays, K1 and K2.
- Cabin temperature sensor
If there is a power interruption, the ZONE TEMP light - Cabin temperature sensor interface
on the P5 panel comes on immediately. The zone - Duct temperature sensor
temperature control system is reset after power has - Duct temperature sensor interface
been restored. - Cabin temperature selector
- Cabin temperature selector interface
Overheat Indication - Zone trim air modulating valve
- Zone trim air modulating valve driver.
Overheat protection is provided by overheat switches in
the flight compartment supply duct and in the supply The backup flight compartment INOP switch is set by
ducts for the passenger cabin. these backup flight compartment failures:
If there is an overheat condition, the ZONE TEMP light - Cabin temperature sensor and selector
on the P5 panel comes on immediately. Push the TRIP - Cabin temperature sensor interface and selector
RESET switch on the P5 panel after the duct has cooled - Cabin temperature sensor and selector interface
to reset the zone temperature control system. - Cabin temperature sensor interface and selector
21-60-00-809 Rev 1 06/03/1999
interface.
Flight Compartment Temperature Control System Failure
Indication The backup flight compartment FAULT switch is set by
these backup flight compartment failures:
A failure of the primary or backup flight compartment
temperature control or a malfunction in the system - Cabin temperature sensor
causes the ZONE TEMP light to come on only when the - Cabin temperature sensor interface
21-60-00
- 161 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - ZONE TEMP INDICATION - FUNCTIONAL DESCRIPTION
- Duct temperature sensor - Standby pack-cabin loop electronics.
- Duct temperature sensor interface
- Cabin temperature selector
- Cabin temperature selector interface
- Zone trim air modulating valve
- Zone trim air modulating valve driver.
21-60-00
- 162 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
BACKUP FWD PASS FLT CONT ELEC ANTI-ICE ENG PRIMARY FLIGHT COMPT INOP
COMPT FAULT FIRE
WARN
MASTER
CAUTION IRS APU HYD OVERHEAD
MASTER
CAUTION
FIRE
WARN
OPEN = INOP
GROUND = FAULT FUEL OVHT/DET DOORS AIR COND
21-60-00
- 163 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - PACK LIGHT INDICATION - FUNCTIONAL DESCRIPTION
THIS PAGE INTENTIONALLY LEFT BLANK
21-60-00-810 Rev 1 12/12/1998
21-60-00
- 164 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - PACK LIGHT INDICATION - FUNCTIONAL DESCRIPTION
Purpose Air Conditioning Packs Temperature Control System
Failure indication
The pack light turns on for over temperature
conditions, and failures of the air conditioning A single failure of the pack control system causes the
temperature control system. PACK light to come on only when the master caution
system is recalled. This shows a BITE check of the
Power Interruption controllers is necessary.
Power interruption indication is given by power If a complete loss of temperature control for the pack
interrupt indication relays. control system occurs, the PACK light comes on and
cannot be reset.
If a power interruption is sensed, the PACK light on
the P5 panel comes on. The pack temperature control The standby pack FAULT switch is set by these standby
system is reset after power has been restored. pack component failures:
the P5 panel after the cooling pack has cooled to reset The pack FAULT switch is set by these pack component
the pack temperature control system. failures:
21-60-00
- 165 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - PACK LIGHT INDICATION - FUNCTIONAL DESCRIPTION
- Zone duct demand signal or interface from opposite
controller
- Partial pack demand signal or interface from
opposite controller
- Ram air temperature sensor or interface
- Ram air door actuator or interface.
21-60-00-810 Rev 1 12/12/1998
21-60-00
- 166 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
L PACK/ENG
28V DC BLEED AIR OVHT
BAT BUS
250F (121C)
AIR COND PACK L PACK DISCHARGE
CONT VALVES TRIP RESET OVHT SWITCH
LEFT SWITCH
P6 CB PANEL 210F (99C)
L TURBINE INLET
K1 POWER K8 PACK OVHT SWITCH
INTERRUPT OVHT
INDICATION RLY RELAY
390F (199C)
MD&T PACK L COMP DISCHARGE
LEFT OVHT SWITCH
L PACK LIGHT ACAU
P5 PANEL
BITE
STBY PACK FAULT
GROUND = FAULT
RIGHT PACK/ZONE
TEMPERATURE CONTROLLER
21-60-00
- 167 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
AIR CONDITIONING -- TEMPERATURE CONTROL - TEMPERATURE BULB
Purpose - The right air conditioning pack on the right high
pressure water separator assembly
The temperature bulbs measure temperature in the - The left air conditioning pack on the left high
critical areas of the air conditioning system. The pressure water separator assembly.
temperature bulbs are for indication only and are not
part of the automatic temperature control system. Training Information Point
- Sensing element
- Electrical connector.
Location
21-60-00
- 168 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details
737-300/400/500 TRAINING MANUAL
ON
TEMPERATURE CONTROLS PANEL
21-60-00-825 Rev 1 03/19/1999
21-60-00
- 169 -
ALTEON PROPRIETARY - Copyright (c) - See title page for details