0 ratings0% found this document useful (0 votes) 83 views3 pagesBrainChild IO-16DI
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content,
claim it here.
Available Formats
Download as PDF or read online on Scribd
Data Acquisition Modules
IO Modules —
Features
Portable
Modbus connectivity
Simple setup and easy handling
Upto 127 Modules on RS485 network
Isolated modules avaiable for special applications
Low-cost 10 modules addition to existing PLC system
LEDs for digital IO status, communication and power supply
‘Standard software for module configuration and trouble shooting
Data acquisition software for data storage and Reabtime analysis on PC
1d with the third party softwares via Modbus RTU Protocol
devices to provide realtime data for SCADA/PLC/HMI
10 modules
Interface with fi
Different types of 10 Modules Al,A0,DI,D0,ATD, Thermocouples all available
Direct reading of temperature without sealing by using RTD and Thermocouple Modules
BrainChild10 Modules
‘Anew line of Modbus based IO modules for data acquisition and other applications are available now. Thase IO modules
‘offer good reliably, low-cost solution for dstrbuted 10 applications. They are portable, easy integrated with existing
Modbus network, and simple to use for end users, Various types of 1O modules are available for different kinds of
requirements. All IO modules have LED indications for visualization of 10 status (Digital) and fault diagnostic analysis.
‘Some models with high isolation among inputs are also available for special applications, 10 Studio software is used to
‘setup communication of 10 modules and checks the 1O status in PC for diagnasis purpose. With Modbus RTU protocol
these 10 modules configured as slaves willbe easy to communicate with Modbus master such as SCADAVPLCIHMI. All
10 madules have 2 wire RS485 interface with Modbus RTU Protocol
Environmental & Physical Communication Approval Standards
‘Operaing temperaire 10° to 150° terface 2ovire, RSA Safely 166 950
Storage temperature 40°C to ¥85°C Modbus adress seting By Dip switch EMC IEC 61000-42AT Level?
Dimension (WaHXD ] 23x 109 98mm Modbus Maxadress 127 only TEC 61000-4-5.AT Level
Wight 105 grams Baud rate 72400, 4800, 9600, 18200, TEC 61000-4-4 Lovel 3
Mounting IN Rail 38400, 57600, 115200 CISPR ITT9S-AT/
arly None, Even, Oa EN 550111998
Stop bis 12 Group 1 Class K
Data Bits 3
Digital Modules
Specifications
lo-4RO 10-8010
Digital Inputs 6 NA NA
No.of Counters 6 NA NA 3
Counter Resolution 326 NA NA 328
Gounter frequency 1 KHz NA NA T KHz
Counter Mode UP/Down NA NA UP/Down
Pulse width Minimum 500 Mito 86 NA NA Minimum $00 Mire 506
Input impedance 2200 ohms NA NA 2200 ohms
Isolation (Field&Logie) 1500 V RVS NA NA 71500 V RMS
‘Status Indication LED for each channel NA. NA LED for each channel
Digital Outputs 0 16 4 3
“Type of Digital output NA ‘Open collector Relay, Form © ‘Open collector
‘Maximum load current_NA "100 mAvchannél OA [1 Aeach ch 100 mA‘channel
‘Maximum load Voltage NA. 36V 00 0VAGI28VC___36V 00.
Tsolation (Fleld&Logic) NA 1500 V RMS 7000 V RMS 71500 V RMS
‘Status Indication NA LED for each channel LED for each channel LED for each channel
Power supply Tt 2VOE te 26 DC 2a VDC. 1210 24V DG.
Combination Module
Specifications
‘Analog Outputs
Digital inputs
Digital Outputs
RTD Inputs.
Power supply
For 10-DAIO module, LED is aval
UP Impedance: 250 Ohms for current UP, 10-DAIO
4190 K Ohms for Voltage UP
0(4)-20 mAIO(2}-10 V DG, Resolution: 12 bt,
Drift: 100 PPM/Deg.¢, Accuracy: 0.05 % of span,
Load: 1000 ofms @ 24 V for Current, 2000 Ohms
{or voltage output
Counter, 32 bt, Frequency: 50 Hz, Pulse width: 20 ms,
Vottage:10-26 VDC
‘Open collector, 36 V DG (Max), 100 mAOutput
Connection 213 wire, Types: PTTOOINIT2O/PT1000,
Resolution: 0.1 deg ©, Isolation: 1500 V RMS
72Vt024V DC
ble for power on and communication status onlyApplications
Application 1: Data acqi nto PC 1601
Pc
S282 to RS485 Converter(SNA-10A)
Seal Link Serial to Ethernet Converter(PC-E)
‘Serial to Ethernet Wireless(SW5502)
Serial to USB Convertor{UPort 150}
Modus
Master a! Modbus
Slaves
S485 Network, Rooper
120.0nm Termination Digital
outputs
Application2: PLC/HMI with 10
Digtal
Mocbus ‘nos
Master
S405 Network Moss
Response
120 On Termination
outs
Model Number
nd 1800
Wedel Number Deserption
10-1601 18 DIGITAL NPUT MODULE INCLUDING COUNTERS
10-1600) "16 DIGITAL OUTPUT MODULE
10-480 “¢ RELAY OUTPUT MODULE
10-8010. DIGITAL INPUT [8 DIGITAL OUTPUT MODULE
TO-8TC. ‘THERMOCOUPLE INPUT MODULE ING, 0- S0n/ & 100001
1O-BTCS ‘BTC INPUT MODULE INCL, 0 50m & #100nV UP FULLY ISOLATED.
TO-GRTD ‘RTO INPUT MODULE - PT 100, N'20, PT000, NT000, NIOOOLG & Ohms
T-BALL ‘BANALOG INPUTO- 20mA74~ 20m
10-8ANV ANALOG INPUTO-5V/1-5V/0- 10V/2~10V
TO-AIS ‘BANALOG INPUT O- 200vA74- 20mA/ 220m FULLY ISOLATED
O-BAIVS ‘BANALOG INPUT O- 1V [0 10V/=1V7 #10V FULLY ISOLATED
TO-BAOT ‘BANALOG OUTPUT MODULE _0(4) -20mA,
10-6A0V ‘BANALOG OUTPUT MODULE 0(2)- 10V
TO-DAIO ‘2RTD UP, 2 ANALOG INPUT O(@) - 20mA 02) -70V,
+ ANALOG OUTPUT 0(4)«20mA/0(2)-10V,
4 DIGITAL INPUTS, 2 DIGITAL OUTPUTS
PoE RS-7321485 TO ETHERNET CONVERTER
SSWS502 RS-730/4221405 10 ETHERNET WIRELESS CONVERTER
SNA-10A RS-232 TO RS-465 CONVERTER,
‘Data Acquistion Sudo PC BASED DATA LOGGING SOFTWARE FORO MODULES
BrainChild
BRAINCHILD Electronic Co., Ltd.
No. 208, Chung Yang Ra., Nan Kang Dist,
Taipo,Taiwan
Tet 86-2-27061209 Fax: 886-2-27061905
E-mail: sales@brainchilé. com.tw
Webste tp twaw-brancni. com.tw poraso