0% found this document useful (0 votes)
48 views2 pages

10 Dow-Filmtec-Bw30-400-34i-Membrane

This document provides product information for Dow Filmtec BW30-400/34i reverse osmosis membrane elements. Key details include: - The elements offer high quality permeate water while minimizing costs and maximize cleaning performance and durability. - Product specifications include an active area of 400 sq ft with a permeate flow rate of 10,500 GPD and a salt rejection rate of 99.5%. - Operating limits include a maximum temperature of 113°F, maximum pressure of 600 psig, and pH range of 2-11 for continuous use.

Uploaded by

CHAMOUX
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
48 views2 pages

10 Dow-Filmtec-Bw30-400-34i-Membrane

This document provides product information for Dow Filmtec BW30-400/34i reverse osmosis membrane elements. Key details include: - The elements offer high quality permeate water while minimizing costs and maximize cleaning performance and durability. - Product specifications include an active area of 400 sq ft with a permeate flow rate of 10,500 GPD and a salt rejection rate of 99.5%. - Operating limits include a maximum temperature of 113°F, maximum pressure of 600 psig, and pH range of 2-11 for continuous use.

Uploaded by

CHAMOUX
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

sales@pureaqua.

com
+1(714) 432-9996 Get a Quote
Reverse Osmosis & Water Treatment Systems +1 (844) 309-7501 www.pureaqua.com

Product Data Sheet

DOW FILMTEC™ BW30-400/34i Element

Description Ideal for: reverse osmosis plant managers and operators dealing with
challenging waters and wastewaters and looking for consistent, high
performance, long element life and increased productivity.

Offering proven performance, DOW FILMTEC™ BW30-400/34i:


• Delivers high quality permeate water while minimizing CAPEX
• Offers the most effective cleaning performance, robustness and
durability due to its widest cleaning pH range (1 – 13) tolerance and
the support of Dow technical representatives
• Includes iLEC™ interlocking end caps, reducing system operating
costs and the risk of o-ring leaks that can cause poor water quality

Product Type Spiral-wound element with polyamide thin-film composite membrane

Product Specifications
Typical
Active Area Feed Spacer Permeate Flow Rate Stabilized Salt Minimum Salt
DOW FILMTEC™ Element (ft2) (m2) Thickness (mil) (GPD) (m3/d) Rejection (%) Rejection (%)
BW30-400/34i 400 37 34 10,500 40 99.5 99.0

1. Permeate flow and salt (NaCl) rejection based on the following standard test conditions: 2,000 ppm NaCl, 225 psi
(15.5 bar), 77°F (25°C), pH 8, 15% recovery.
2. Flow rates for individual elements may vary but will be no more than 15% below the value shown.
3. Stabilized salt rejection is generally achieved within 24-48 hours of continuous use; depending upon feedwater
characteristics and operating conditions.
4. Sales specifications may vary as design revisions take place.
5. Active area guaranteed ± 3%. Active area as stated by Dow Water & Process Solutions is not comparable to nominal
membrane area often stated by some manufacturers. Measurement method described in Form No. 609-00434.

Element
Dimensions

A B C D
DOW FILMTEC™ Element (in.) (mm) (in.) (mm) (in.) (mm) (in.) (mm)
BW30-400/34i 40.0 1,016 40.5 1,029 7.9 201 1.125 ID 29 ID

1. Refer to Dow Water & Process Solutions Design Guidelines for multiple-element applications. 1 inch = 25.4 mm
2. Element to fit nominal 8-inch (203-mm) I.D. pressure vessel.
3. Individual elements with iLEC endcaps measure 40.5 inches (1,029 mm) in length (B). The net length (A) of the elements
when connected is 40.0 inches (1,016 mm).

Page 1 of 2 ®™ Trademark of The Dow Chemical Company (“Dow”) or an affiliated company of Dow Form No. 609-00481, Rev. 2
August 2015
[email protected]
+1(714) 432-9996 Get a Quote
Reverse Osmosis & Water Treatment Systems +1 (844) 309-7501 www.pureaqua.com
Operating and Maximum Operating Temperature a 113°F (45°C)
Cleaning Limits Maximum Operating Pressure 600 psig (41 bar)
Maximum Element Pressure Drop 15 psig (1.0 bar)
pH Range, Continuous Operation a 2 – 11
pH Range, Short-Term Cleaning (30 min.) b 1 – 13
Maximum Feed Silt Density Index (SDI) SDI 5
Free Chlorine Tolerance c < 0.1 ppm
a Maximum temperature for continuous operation above pH 10 is 95F (35C).
b Refer to Cleaning Guidelines in specification sheet 609-23010.

c Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. Since oxidation

damage is not covered under warranty, Dow Water & Process Solutions recommends removing residual free chlorine by pretreatment prior to
membrane exposure. Please refer to technical bulletin "Dechlorinating Feedwater" for more information.

Additional Before use or storage, review these additional resources for important information:
Important
Information  Usage Guidelines for DOW FILMTEC™ 8” Elements
 System Operation: Initial Start-Up

Regulatory Note These membranes may be subject to drinking water application restrictions in some
countries; please check the application status before use and sale.

Product Dow has a fundamental concern for all who make, distribute, and use its products, and for
Stewardship the environment in which we live. This concern is the basis for our product stewardship
philosophy by which we assess the safety, health, and environmental information on our
products and then take appropriate steps to protect employee and public health and our
environment. The success of our product stewardship program rests with each and every
individual involved with Dow products—from the initial concept and research, to
manufacture, use, sale, disposal, and recycle of each product.

Customer Notice Dow strongly encourages its customers to review both their manufacturing processes and
their applications of Dow products from the standpoint of human health and environmental
quality to ensure that Dow products are not used in ways for which they are not intended or
tested. Dow personnel are available to answer your questions and to provide reasonable
technical support.

Notice: The use of this product in and of itself does not necessarily guarantee the removal of cysts and pathogens from water.
Effective cyst and pathogen reduction is dependent on the complete system design and on the operation and maintenance of
the system.

NOTICE: No freedom from infringement of any patent owned by Dow or others is to be inferred. Because use conditions and
applicable laws may differ from one location to another and may change with time, Customer is responsible for determining
whether products and the information in this document are appropriate for Customer's use and for ensuring that Customer's
workplace and disposal practices are in compliance with applicable laws and other government enactments. The product shown
in this literature may not be available for sale and/or available in all geographies where Dow is represented. The claims made
may not have been approved for use in all countries. Dow assumes no obligation or liability for the information in this document.
References to “Dow” or the “Company” mean the Dow legal entity selling the products to Customer unless otherwise expressly
noted. NO WARRANTIES ARE GIVEN; ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED.

Page 2 of 2 ®™ Trademark of The Dow Chemical Company (“Dow”) or an affiliated company of Dow Form No. 609-00481, Rev. 2
August 2015

You might also like